R&S CEMS100 Compact EMS/EMI Test Platform Standard-compliant all-in-one solution for EMS measurements

Similar documents
R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

R&S ZN-Z154 Calibration Unit Specifications

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S ZN-Z85 Switch Matrix Specifications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S DST200 RF Diagnostic Chamber Specifications

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S FSV-K40 Phase Noise Measurement Application Specifications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

Your partner in testing the Internet of Things

R&S RSC Step Attenuator Where precise signal levels count

R&S HF907DC SHF Downconverter Specifications

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S ZNrun Automated Test Software PC-based server platform for automated VNA tests

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

R&S GX465 Digital Wideband Storage Device Recording and replaying of I/Q data with up to 80 MHz bandwidth

R&S ZVA110 Vector Network Analyzer Specifications

R&S Spectrum Rider FPH Handheld spectrum analyzer

R&S PSL3 Industrial Controller The powerful industrial controller

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Versatile EMS and EMI measurements for the automobile sector

R&S GX460 Digital Wideband Storage Device Recording and replaying device for I/Q data with up to 40 MHz bandwidth

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

Test and measurement solutions for electronics manufacturers

R&S AVG050 DVB Satellite Receiver Specifications

R&S WMS32 Wireless Measurement System Software Specifications

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

R&S GU221 Filter Control Unit Specifications

R&S TSMx Radio Network Analyzers Powerful scanner family for mobile applications

R&S SGU100A SGMA Upconverter Specifications

RF amplifier testing from wafer to design-in

R&S ZN-ZTW Torque Wrench Specifications

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S M3TR R&S VT3050C 50 W VHF/UHF Compact Power Amplifier Specifications

R&S MP007 Portable Direction Finding System Compact and extremely precise

Product Brochure Version R&S AdVISE Visual Inspection Software A new way to eliminate human inattention

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

R&S RT-ZM Modular Probe System

R&S DDF200M Digital Direction Finder Specifications

Scope of the art Scope Rider Handheld digital oscilloscope

Oscilloscopes for debugging automotive Ethernet networks

R&S FPS-K18 Amplifier Measurements Specifications

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

R&S FSW-K144 5G NR Measurement Application Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S DST200 RF Diagnostic Chamber Accurate radiated testing of wireless devices 700 MHz to 6 GHz

R&S TS-PSM5 High-Power Switching Module Automotive DUT supply and load switching up to 50 A

EX-IQ-Box Digital Signal Interface Module Specifications

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

R&S FPC1000 Spectrum Analyzer Specifications

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S ZND Vector Network Analyzer Specifications

R&S TS-PIO4 Digital Functional Test Module 32-channel programmable digital I/O module

R&S RT-Zxx Standard Probes Specifications

R&S EFL110/EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

R&S SGMA Product Family Compact fast reliable

R&S VENICE On air. 24/7.

R&S BBL200 Broadband Amplifier Specifications

R&S BBA130 Broadband Amplifier The amplifier you can tune

R&S SFC Compact Modulator and R&S SFC-U Compact USB Modulator Test signals for TV and audio broadcasting handy and economical

Test Device Containment Module (TCM) Optimal conditions for reliable results

Be ahead in 5G. Turn visions into reality.

R&S TS-PSM3 High-Power Switching Module Automotive DUT supply and load switching up to 30 A

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

R&S CONTEST ITS Test cases and applications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards

Troubleshooting EMI in Embedded Designs White Paper

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

R&S NRPM Over-the-Air (OTA) Power Measurement Solution Specifications

R&S FPC Spectrum Analyzer Unexpected performance in entry class

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

R&S TS-PFG Function Generator Module Dual-channel arbitrary waveform generator with isolated outputs

R&S ZND Vector Network Analyzer Basic, solid-performance network analysis

Efficient analysis of power and signal integrity and EMC

Mastering Phase Noise Measurements (Part 3)

Radar signal interception moves into the digital age. Innovative ELINT solution from Rohde & Schwarz. Radar signal interception

R&S FPC-Z10 Teaching Kit Getting Started

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

Transcription:

CEMS100_bro_en_3606-9491-12.indd 1 Product Brochure 02.00 Test & Measurement R&S CEMS100 Compact EMS/EMI Test Platform Standard-compliant all-in-one solution for EMS measurements 18.02.2015 18:06:28

R&S CEMS100 Compact EMS/EMI Test Platform At a glance Setting up an EMS/EMI test system is a very complex process requiring significant investment. The steps involved include custom planning, design, installation and configuration of various components and standalone instruments as well as the RFshielded anechoic chamber. Rohde & Schwarz is now offering the standardized R&S CEMS100 test platform that is the company's first flexible, reliable and cost-effective off-the-shelf solution for radiated EMS measurements in line with IEC/EN 61000-4-3. The advanced R&S CEMS100 is a compact EMS/EMI test platform covering all common frequency ranges and field strengths needed for precompliance tests and certification. It meets three important requirements for an EMS test system: The test system offers assured overall performance when combined with qualified test chambers; the attainable field strength was determined based on extensive measurements performed together with chamber manufacturer Albatross Projects GmbH; as a result, compliance with the relevant test standards is ensured As a standardized and preconfigured all-in-one solution, the test system allows efficient field generation with outstanding field uniformity; users can install and start up the test system on their own; it represents a highly efficient and cost-effective solution for certification and development The test system's modular design allows worldwide support and calibration services and can be expanded to handle new technologies The core of the platform consists of various Rohde & Schwarz system components such as signal generators, switching units, broadband amplifiers and EMC software. These components can be easily exchanged, expanded or upgraded without modifying the base system. Using a test receiver with the appropriate software option, the system can be expanded to perform automated EMI measurements without changing antennas. Key facts Certifiable base system for commercial standards EMS measurements from 80 MHz to 3 GHz, 10 V/m EMS and EMI measurements without changing antennas Scalable and expandable for further EMC applications Various proven EUT monitoring capabilities Immediate deployment with preconfigured hardware and software 2 CEMS100_bro_en_3606-9491-12.indd 2 18.02.2015 18:06:31

R&S CEMS100 Compact EMS/EMI Test Platform Benefits and key features All-in-one solution from the market leader in EMC T & M equipment Ideally matched components for top efficiency Defined system characteristics including assured field strength Combinable with many different EMC test chambers Complete test system ready to put into operation page 4 Efficient Scalable system, optimized for certification and development Easy expansion for EMI with test receiver and software option EMS and EMI measurements without changing antennas Easy integration into existing EMC test environments Worldwide support and service with 24 h telephone support page 7 Future-ready Flexibility to handle ongoing technological advances with standard measuring instruments Options for all common EMC test applications Prepared for 6 GHz, conducted measurements and performance upgrades page 8 Rohde & Schwarz R&S CEMS100 Compact EMS/EMI Test Platform 3 CEMS100_bro_en_3606-9491-12.indd 3 18.02.2015 18:06:31

All-in-one solution from the market leader in EMC T & M equipment Ideally matched components for top efficiency Efficient generation of fields is crucial in an EMS test system. The best performance is achieved through high amplifier power in combination with minimal cable losses, an efficient antenna to ideally illuminate the homogeneous area and an optimum absorber layout. In the R&S CEMS100, a high-performance EMS/EMI hybrid antenna is used to cover the complete frequency range. Moreover, the amplifier power is matched to the antenna gain. Thanks to the compact system design and full remote control via LAN, the system can be operated in small test chambers directly next to the chamber's connector panel. In conjunction with low-loss RF cables, top RF performance is achieved at the antenna. Components of the R&S CEMS100 CEMS100 SMB100A RF and microwave signal generator Amplifier unit Directional coupler OSP open switch and control platform EMC32 EMC measurement software NRP2 power meter ESR EMI test receiver (optional) 4 CEMS100_bro_en_3606-9491-12.indd 4 18.02.2015 18:06:32

The R&S CEMS100 includes all the components required in an advanced EMS test system: Signal generator with amplitude modulation (AM) Switching unit for all RF paths Broadband amplifier with diverse control options Power meter with two power sensors High-performance hybrid antenna for EMS and EMI measurements Interlock monitoring for protection of personnel during EMS testing Full-compliance test software for cost-effective, fully automated EMS measurements based on the marketleading R&S EMC32 EMC measurement software Options R&S ESR EMI test receiver or R&S ESRP EMI test receiver and R&S EMC32 EMI software options EMC test chamber: qualified for use in various types of chambers Field probe Defined system characteristics including assured field strength A major investment is required to build an EMC test setup that includes a test chamber and test system. Accordingly, it is prudent to plan ahead and avoid tedious or costly optimizations that might be required subsequently. Such problems are prevented from the start when the R&S CEMS100 is combined with different EMC anechoic chamber types from Albatross Projects GmbH since the R&S CEMS1xx has already been qualified for use in these chambers. A field strength of 10 V/m + 80 % AM is reliably achieved and assured across the entire frequency range. The cable lengths are matched to the chamber. A list of chamber types is available upon request. Configuration of disturbance signal generation with an R&S CEMS100 for EMS testing. Rohde & Schwarz R&S CEMS100 Compact EMS/EMI Test Platform 5 CEMS100_bro_en_3606-9491-12.indd 5 18.02.2015 18:06:32

Combinable with many different EMC test chambers Complete test system ready to put into operation The R&S CEMS100 all-in-one solution provides top system performance and comes with the complete documentation. The test system is fully tested and if possible without a test chamber supplied in a calibrated and preconfigured state including all transducer and directional coupler values. The test chamber has a major impact on the field strength. This is due to effects such as chamber resonance, absorber layout and distance from the absorbers to the antenna or homogeneous area. The R&S CEMS100 is designed for a field strength of 18 V/m CW (or 10 V/m with 80 % AM) based on experience gained with a number of test systems. Only the field strength over the homogeneous area has to wait to be calibrated in the chamber. When using small chambers, deviations can arise in some subfrequency ranges so that the intended field strength is not attained under certain circumstances 1). In some cases, modifying the floor absorber layout will improve the situation. 1) Power required in a 3 m semi-anechoic chamber from Albatross Projects GmbH for vertical and horizontal polarization with 4 x 4 floor absorber layout Horizontal polarization 180 Required power in W 160 140 120 100 80 60 40 20 0 0 0.5 1 1.5 2 2.5 3 Frequency in GHz 250 Vertical polarization Required power in W 200 150 100 50 0 0 0.5 1 1.5 2 2.5 3 Frequency in GHz 6 CEMS100_bro_en_3606-9491-12.indd 6 18.02.2015 18:06:33

Efficient EMS and EMI measurements without changing antennas Scalable system, optimized for certification and development Depending on the particular measurement task (100 % standard-compliant testing or cost-effective solution for precompliance tests), frequency ranges from 80 MHz to 1 GHz (or 3 GHz) are available along with various amplifier power levels. For example, the R&S CEMS130 (frequency range up to 3 GHz) can perform acceptance tests and precompliance tests in line with IEC/EN 61000-4-3 and a related product standard such as EN 55024 for information technology equipment (ITE). Overview of system variants 2) Type Frequency Performance R&S CEMS110 80 MHz to 1 GHz 100 % standard-compliant R&S CEMS111 80 MHz to 1 GHz for precompliance tests 2) R&S CEMS130 80 MHz to 3 GHz 100 % standard-compliant R&S CEMS131 80 MHz to 3 GHz for precompliance tests 2) In individual small frequency subranges, the field strength is possibly not attained. Easy expansion for EMI with test receiver and software option Since EMI and EMS measurements are performed in most test chambers, the system is ready for both types of measurements. Along with the R&S ESR EMI test receiver for full-compliance measurements or the R&S ESRP EMI test receiver for precompliance measurements, the EMI option also includes the appropriate R&S EMC32 software options to allow automated EMI tests with a turntable and mast controller. It also allows automatic switching between emission and EMS measurements without reconnecting the test receiver. Using the optional R&S EMC32-K11 test sequencer, EMI and EMS measurements can be automatically performed in sequence. Changing antennas in the test chamber is a time-consuming process since the antennas can be unwieldy and it is usually necessary to reposition the absorbers. One benefit here is that the antenna used in the R&S CEMS100 covers the complete frequency range for common commercial radiated EMC measurements from 30 MHz to 6 GHz for EMI and from 80 MHz to 3 GHz for EMS in line with CISPR and EN standards. During testing in a fully anechoic room (FAR) with a floor absorber between antenna and EUT without a height scan (measurement distance of 3 m from antenna phase center to EUT), it is possible to switch directly between emission and EMS measurements without reconfiguration. The EMI option is necessary for these tests. Easy integration into existing EMC test environments The R&S CEMS100 control software is the tried and tested R&S EMC32, which is used on a daily basis in many test laboratories worldwide. User experience is tapped continuously to aid in further development of the software. Users and test houses that already rely on the R&S EMC32 software have confirmed that it is very easy to integrate the R&S CEMS100 into existing test environments. Worldwide support and service with 24 h telephone support In contrast to standalone custom solutions, a standardized system makes expert knowledge widely and readily available. To ensure that work proceeds smoothly in test laboratories, test engineers can take advantage of Rohde & Schwarz customer support and 24 h telephone support at regional system centers as well as locally. Rohde & Schwarz R&S CEMS100 Compact EMS/EMI Test Platform 7 CEMS100_bro_en_3606-9491-12.indd 7 18.02.2015 18:06:33

Future-ready Flexibility to handle ongoing technological advances with standard measuring instruments The core of the R&S CEMS100 consists of various Rohde & Schwarz system components such as signal generators, switching units, broadband amplifiers and EMC software. These components can be easily exchanged, expanded or upgraded without modifying the base system. The customary fast calibration service from Rohde & Schwarz is also available for the test platform. Assuming the R&S EMC32 software provides appropriate support, other measuring instruments with comparable functionality can be deployed in the system, e.g. as a substitute during calibration. This ensures high system availability for the user. Extensive functionality for EUT monitoring via diverse interfaces LAN LAN (TCP/IP) CANoe, CANalyzer application User s monitoring PC CAN, MOST, LIN, FlexRay User-specific RS-232 EMC32-S RS-232 LAN GPIB, LAN RS-232, VISA USB Signal processing Video monitoring system Camera Measurement or stimulus device Physical parameters DAQ boards Signal conversion EUT (V, I, f, T,...) TTL/voltage I/Q Signal source 8 CEMS100_bro_en_3606-9491-12.indd 8 18.02.2015 18:06:33

Options for all common EMC test applications In its basic configuration, the R&S EMC32 EMC measurement software already offers all the functionality needed to operate the R&S CEMS100. This also includes powerful integrated functions for EUT monitoring such as control and query of individual measuring instruments and I/O interfaces, communications with EUT and video monitoring software or with in-vehicle electronics systems via CANoe or CANalyzer. All this allows users to easily handle interfacing of the EUT controller and tests. Moreover, the R&S EMC32 software offers all relevant expansion options for present and future measurement tasks, including options for automotive and MIL standards, wireless measurements and support for reverberation chambers. Prepared for 6 GHz, conducted measurements and performance upgrades The R&S CEMS100 is prepared for the frequency range from 80 MHz to 6 GHz. This applies to all its key components including the signal generator, power measurement equipment and antenna. By adding an amplifier for 3 GHz to 6 GHz, the frequency range of the system platform can be extended very easily. An extension downward is also possible for conducted measurements. Since the frequency range including the amplifier starts at 9 khz, only the appropriate transducers such as coupling/decoupling networks (CDN), EM clamps or bulk current injection (BCI) clamps and a 6 db attenuator are needed. Using suitable transducers, the amplifier power is adequate for much more than 10 V + 80 % AM. Due to its modular design, power upgrades for the Rohde & Schwarz amplifier are easy to implement since Rohde & Schwarz service only has to install additional modules. As a result, standards that require higher test levels can be covered as well. Overview of available R&S EMC32 options EMC32-K56 EMI tests in line with MIL-STD-461 EMC32-K51 EMI band evaluations EMC32-K22 azimuth charts EMC32-K23 3D result evaluation EMC32-K24 interactive autotest extension EMC32-K33 RVC EMI test EMC32-K10 EMI autotest EMC32-K2 radiocommunications tests EMC32-K251 TD-SCDMA support EMC32-K26 LTE support EMC32-K1 automotive and military EMS tests EMC32-K3 RVC EMS test EMC32-K4 EMS autotest EMC32-K6 MIL-STD CS103, 104, 105 EMC32-K8 database interface EMC32-K21 application interface EMC32-K7 generic device drivers EMC32-K11 test sequencer -K56 -K51 -K22 -K23 -K24 -K33 -K10 -K2 -K251 -K26 -K1 -K3 -K4 -K6 -K8 -K21 -K7 -K11 EMC32-EB Basic emission measurements EMC32-S Basic immunity measurements EMC32 General options Rohde & Schwarz R&S CEMS100 Compact EMS/EMI Test Platform 9 CEMS100_bro_en_3606-9491-12.indd 9 18.02.2015 18:06:33

Specifications in brief Specifications in brief Frequency range of R&S CEMS110/111 EMS 80 MHz to 1 GHz Frequency range of R&S CEMS130/131 EMS 80 MHz to 3 GHz Frequency range EMI (optional with appropriate Rohde & Schwarz test receiver) 80 % AM 1 khz; meets uniformity in line with IEC/ EN 61000-4-3 for an area of 1.5 m 1.5 m in a qualified 3 m semi-anechoic chamber (SAC); distance from antenna phase center to EUT: 3 m 80 % AM 1 khz; meets uniformity in line with IEC/ EN 61000-4-3 for an area of 1.5 m 1.5 m in a typical 3 m semi-anechoic chamber (SAC); distance from antenna phase center to EUT: 3 m 30 MHz to 6 GHz Field strength (100 % standard-compliant) for R&S CEMS110/130 Field strength (for precompliance tests) for R&S CEMS111/131 Modulation 10 V/m 10 V/m (typ.) 1) AM, CW pulse (optional) automatic determination of immunity thresholds measurement of radiated and conducted susceptibility use in product certification and precompliance tests measurements in line with commercial, military and automotive standards flexible adaptation to requirements of various EMC applications automatic control of system components integrated calibration concept various capabilities for EUT monitoring and stimulation interface to external EUT monitoring software flexible report generation (HTML, RTF, PDF) EUT-specific or application-specific data management operation of overall system like a single instrument Software features Power supply Input voltage range Power consumption 230 V, single-phase, CEE connector, 16 A, 6 h 100 V to 240 V, 50 Hz to 60 Hz, autoranging max. 1500 VA 2) Antenna data Frequency range 30 MHz to 6 GHz VSWR starting at 200 MHz 2 (typ.) Antenna gain starting at 200 MHz 8.5 dbi (typ.) Connector N female Impedance 50 Ω General data Environmental conditions Electromagnetic compatibility operating temperature range +5 C to +40 C storage temperature range 20 C to +70 C relative humidity 90 % at +40 C electromagnetic interference < 1 GHz EMI emission limits for devices in class A of 40 db in line with EN 55011 group 1 or FCC 047 CFR part 18 are exceeded; the system may only be used in shielded rooms EMI emission limits for devices in class A of 40 db in line with EN 55011 group 2 or FCC 047 CFR part 18 are exceeded; the system may only be used in shielded rooms 600 mm 1600 mm 800 mm (23.6 in 63 in 31.5 in) max. 185 kg (408 lb) electromagnetic interference 1 GHz Dimensions (W H D) Weight 1) 2) In individual small frequency subranges, the field strength is possibly not attained. Depends on system configuration. 10 CEMS100_bro_en_3606-9491-12.indd 10 18.02.2015 18:06:33

Ordering information Designation Type Order No. Compact EMS/EMI Test Platform, 80 MHz to 1 GHz (100 % standard-compliant) Compact EMS/EMI Test Platform, 80 MHz to 1 GHz (for precompliance tests) 1) Compact EMS/EMI Test Platform, 80 MHz to 3 GHz (100 % standard-compliant) Compact EMS/EMI Test Platform, 80 MHz to 3 GHz (for precompliance tests) 1) Options Accessories for Conducted EMS (attenuators, cables, CDN 801-M2/M3 with calibration unit) R&S CEMS110 R&S CEMS111 R&S CEMS130 R&S CEMS131 1521.5002.02 1520.7799.02 1521.5019.02 1521.5025.02 R&S CEMS-ZCS 1522.7838.02 RF Cable for Conducted EMS, system output for RF feedthrough for R&S CEMS-ZCS R&S CEMS-CCON 1522.7796.02 Field Probe Mast and Fiber-Optic Cables (duplex) FC (male)/st (male), R&S CEMS-FP01 1520.7899.02 consisting of cables (length: 5 m and 15 m( and fiber-optic feedthrough Field Probe Mast and Fiber-Optic Cables (duplex) HFBR-45xx (male)/hfbr-45xx R&S CEMS-FP02 1520.7901.02 (male), consisting of cables (length: 5 m and 15 m) and fiber-optic feedthrough Equipment supplied Rack, set of cables, measuring instruments, amplifiers, antenna, control computer with installed software, documentation. Anechoic chamber, antenna mast, turntable, controller for antenna mast/turntable, field probe not included. 1) In individual small frequency subranges, the field strength is possibly not attained. Service options Extended Warranty, one year R&S WE1 Extended Warranty, two years R&S WE2 Extended Warranty, three years R&S WE3 Extended Warranty, four years R&S WE4 Extended Warranty with Calibration Coverage, one year R&S CW1 Extended Warranty with Calibration Coverage, two years R&S CW2 Extended Warranty with Calibration Coverage, three years R&S CW3 Extended Warranty with Calibration Coverage, four years R&S CW4 Please contact your local Rohde & Schwarz sales office. Your local Rohde & Schwarz expert will help you determine the optimum solution for your requirements. To find your nearest Rohde & Schwarz representative, visit www.sales.rohde-schwarz.com Rohde & Schwarz R&S CEMS100 Compact EMS/EMI Test Platform 11 CEMS100_bro_en_3606-9491-12.indd 11 18.02.2015 18:06:33

Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability About Rohde & Schwarz The Rohde & Schwarz electronics group is a leading supplier of solutions in the fields of test and measurement, broadcast and media, secure communications, cyber security, and radiomonitor ing and radiolocation. Founded more than 80 years ago, this independent global company has an extensive sales network and is present in more than 70 countries. The company is headquartered in Munich, Germany. Sustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownership Certified Quality Management ISO 9001 Certified Environmental Management ISO 14001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD 3606.9491.12 Version 02.00 February 2015 (as) R&S CEMS100 Compact EMS/EMI Test Platform Data without tolerance limits is not binding Subject to change 2014-2015 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany 3606.9491.12 02.00 PDP 1 en Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 82 28 +86 400 650 58 96 customersupport.china@rohde-schwarz.com 3606949112 CEMS100_bro_en_3606-9491-12.indd 12 18.02.2015 18:06:34