Magnum Dynalab MD 109. TRIODE REFERENCE FM TUNER featuring the WORLD SOURCE PLATFORM

Similar documents
Magnum Dynalab MD 108T ANALOG FM TUNER

MagnumDynalab MD 108T SIGNATURE EDITION ANALOG FM TUNER

Magnum Dynalab MD 105/105R ANALOG FM TUNER

2.0 Wall Mount TV Soundbar Instruction Manual

Model 1606 Super. User Manual

Utility Amplifier GA6A Model

TS2.8 Sub OWNER S MANUAL

SATRI AMPLIFIER AMP-51R. Owner s Manual

PH-1. Italian MM & MC Phono Preamplifier OWNER S MANUAL

ZVOX AccuVoice TV Speaker MODEL AV150.

By CHANNEL VISION. Flush Mount Amplifier A0350

HD Digital MPEG2 Encoder / QAM Modulator

Register your product and get support at SDV5122/27. EN User manual

ZvBox 150. HD video distribution over COAX Get Going Guide

HD Digital MPEG2 Encoder / QAM Modulator

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

DisplayPort Extender over 2 LC Fibers

English. User Manual sub8 Subwoofer SUBWOOFER. Supporting your digital lifestyle

1812R Blues King 12. User Manual

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

Orpheus. Phono Preamplifier. by Thrax Audio. Operating Manual. Manual issued 05/03/2012 CAUTION

HD Digital Set-Top Box Quick Start Guide

CP1 OAD. Owner s Manual. Stereo Control Preamplifier. Ultrafidelity

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234

BP2-MM MM Phono Preamplifier Owner s Manual

Technical Specifications

HP6E Operating Manual. August 2012

Reference 150 LINEAR

ECP 2. Owner's Manual. High Performance Balanced Phono Stage. Version 1.0 ENGLISH

Evolution Digital HD Set-Top Box Important Safety Instructions

DisplayPort Extender over 2 LC Fibers

OWNER S MANUAL EVOLUTION SERIES POWERED SUBWOOFER ES-SUB-EVO6-100

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

Calaf integrated stereo amplifier

Power Source The equipment should be connected to a power supply only of the type described in this manual or as marked on the equipment.

MON8-1 1U 8-Channel Multi-Display Video Monitor

Extender w/ RS-232 and 2-way IR


TV Ears Wireless Speaker User Manual

VK-P10SE WARRANTY REGISTRATION FORM

POWER AMPLIFIERS HOPE, AR Make sure to return your warranty card. or register your amplifier online at.

CR42 LANCASTER

BP2-MM/MC Phono Preamplifier Owner s Manual

ZVOX AccuVoice TV Speaker Model AV203

Reference CD-2.2linear MK2

Reveal 402 / 502 / 802. English Manual

Check our knowledge base at

Reference DSD1.1 d/a Converter 32Bit/768KHz DSD256 d/a Converter

ZVOX AccuVoice TV Speaker Model AV203

IMPORTANT SAFETY INSTRUCTIONS

Q-TV2. User Manual. for Screens

LIGHT COPILOT II. elationlighting.com Internet:

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

TV Ears TV Speaker Installation Guide

Introduction. Important Safety Instructions

SAFETY INFORMATION. 7. Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

SpectraPulse Ultra Wideband Wireless Microphone System

HeadAmp 4 Pro. User s Manual. Project Series. Five Channel Headphone Amp with Listen and Talkback

Content. User s Manual 3. Owner s Manual Ver. 1.1 / June Introduction...4. Mytek Package Content Features...

Operating Instructions

LCD VALUE SERIES (32 inches)

English User Manual. sub8 Subwoofer SUBWOOFER. Supporting your digital lifestyle

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

SwiftMix Automation Safety

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

PROFESSIONAL 2 CHANNEL SOLID-STATE MIC / LINE PREAMPLIFIER USER S MANUAL

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

Important Safety Instructions

Installation Manual VIP 1003

CPH-10 SUBWOOFER OWNERS MANUAL

PREAMPLIFIER INTRODUCTION INSTRUCTIONS FOR USE. Thank you for purchasing the Musical Fidelity A3 CR remote control preamplifier.

Linear200 Intergrated Tube Amplifier

SW 50. Powered Subwoofer with Built-in Stereo Crossover

Owner s Manual. Model PH8 Phono Preamplifier

MON8-1/SDI 1U 8-Channel SDI Digital Multi-Display Video Monitor

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL

Audio. 4K Ultra HD Extender. w/ RS-232 and 2-way IR GTB-UHD2IRS-ELRPOL-BLK. User Manual. Release A2

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

Monochrome Video Monitors

ZIG-POEPRO-70A. HDBaseT HDMI Extender

In-Line or 75 Ohm In-Line

28 4K LED monitor. User Manual M284K

FD Trinitron Colour Television

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

bel canto SEP2 Single Ended Triode Tube Preamplifier User's Guide and Operating Information

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

Owner's Manual. Model PH6 PHONO PREAMPLIFIER.

Passive Four Channel Stereo/Mono Mixer/Splitter. Artcessories. User's Manual

4 PORT HDMI SWITCH

OWNER S MANUAL HD-2CAT-1080P-130. Binary 2CAT Extender WELCOME TO THE BINARY BRAND OF PRODUCTS

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

DISTRIBUTION AMPLIFIER

MON3-2W/HR MON4-2W/HR (Document P/N Rev-B)

Issue date : 9/11/00. Rogue Audio Tempest Vacuum Tube Integrated Amplifier. Owners Manual. Vacuum Tube Amplifiers

LED TV MODEL NO.: NE22K5BG. Please read this manual carefully before installing and operating the TV. Keep this manual handy for further reference

OPERATIONS MANUAL FOR EDISON PROFESSIONAL Professional ABS Molded Loudspeaker M4000

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Prodipe DSP UHF systems and microphones

Pre1. Balanced Control Preamplifier. User's Guide and Operating Information

Transcription:

Magnum Dynalab MD 109 TRIODE REFERENCE FM TUNER featuring the WORLD SOURCE PLATFORM INSTRUCTION MANUAL - 1 -

TABLE OF CONTENTS A MESSAGE FROM THE PRESIDENT 3 UNPACKING YOUR MD 109 4 CONTROL FUNCTIONS 5 IMAGE OF MD-109 FRONT PANEL 6 INSTALLING THE MD 109 7 PROGRAMMING THE TOUCH SCREEN 10 LAYOUT 11 RECEPTION TECHNIQUES 12 FM RECEPTION AIDS AND ACCESSORIES 13 OPERATING THE CONTROL SYSTEM USING THE HANDHELD 14 IMAGE OF RC2 REMOTE 15 TROUBLESHOOTING 16 SPECIFICATIONS 17 SAFETY SHEET 18 LIMITED WARRANTY 19-2 -

A Message from the President Thank you for choosing the Magnum Dynalab MD 109 Reference FM Tuner complete with our World Source Platform. Great care has been taken in the design, manufacturing and selection of components for the MD 109 Tuner in order to ensure many years of listening enjoyment. The MD 109 is the culmination of years of research and development. We have expended considerable effort at every phase of the design process to achieve the highest level of performance. We have used only the finest components throughout the unit, including a separate large torroidal transformer for the audio stage, which incorporates our new TRACC technology (Triode Reference Audio Control Center). We appreciate your decision to purchase the MD 109 FM tuner. Please feel free to contact us if you have any comments or suggestions on improving your FM listening experience. You may call us on our toll free number (1-800-551-4130) or via our direct line when outside North America (1-905-791-5888) or contact us via email at: info@magnumdynalab.com. We at Magnum Dynalab are here to serve your audio source needs. Respectfully yours, Larry Zurowski President - 3 -

UNPACKING YOUR MD 109 Carefully inspect all sides of the shipping carton for damage. If there are marks or holes in the carton, make note of the location in relation to the unit inside. Any obvious dents or scuffmarks should alert you to the possibility of damage. Open the top flaps and carefully lift the transport case out of the carton. Carefully remove the MD 109 from the box and wrapping, inspect all sides. Pay special attention to the corresponding areas on the unit where damage if any was found on the shipping carton. If damage is evident, document the type and extent of the damage, then repack the unit and call the dealer. If your unit was delivered by a common carrier (Eg. UPS) and you have found it to be damaged, contact the carrier immediately for instructions. KINDLY DO NOT SEND THE UNIT BACK TO THE SHIPPER UNTIL YOU HAVE BEEN ASKED TO DO SO. SHIPPNG THE UNIT BACK PREMATURELY MAY VOID ANY CLAIM FOR DAMAGE THAT YOU MAY HAVE. DO NOT DISCARD THE PACKING MATERIALS AND CARTONS. Should you need to return the unit for any reason, it must arrive safely and suitably packaged in order for our receiver to accept it from the carrier. Also, if the unit has incurred damage as a result of improper packaging, it is not likely that a claim for the damage against the carrier will be successful. Likewise, when applicable we will ship your unit back to you only in factoryapproved packaging. However, if the unit were to arrive at our factory in anything other than factory approved packaging, we reserve the right to re-pack the unit in factory-approved packaging and charge the cost of the packaging to the shipper. This is the only way we can assure you of a safe return (damage by carrier excepted). - 4 -

CONTROL FUNCTIONS The MD 109 is equipped with an audio sensing circuit, which protects the unit from any unsafe operating conditions. If an unsafe operating situation should occur the unit will automatically be muted, and if the fault lasts more than two minutes a light will flash on the circuit board and the unit will not come back on until serviced The following functions are displayed clearly on the touch screen. Each funtion s utility is explained below. 1. POWER: Controls the power to all display functions. When in the standby condition the screen will display the Magnum Dynalab logo and the word power in the lower left hand corner. 2. MUTE: Controls the elimination of inter-station noise. It is recommended that, when receiving marginal signals, the mute be set to off. This will eliminate intermittent loss of signals that fall below a specific signal value. The word mute will appear on the screen when activated. 3. STEREO: Controls whether the tuner is operating in Stereo or Mono mode. The word stereo will be displayed in the right hand corner of the screen when you are in the stereo mode. 4. BAND: This switch controls the IF (intermediate frequency) selectivity. The setting you are on will be displayed in the top right hand corner of the screen. The different settings are described below. a. Super Narrow: Controls the IF super narrow setting. This setting should only be used in extreme reception conditions of adjacent channel problems. The words super narrow will be displayed on the screen when activated with the Band switch. b. Narrow: This setting combines excellent frequency response with high adjacent channel selectivity. The word narrow will be displayed on the screen when activated by the Band switch. c. Wide: Controls the ultra wide IF setting and offers the best frequency response. The word wide will be displayed on the screen when activated by the Band Switch. 5. DIM: When activated, the brightness of the screen will be reduced by 50 %; this will extend the life of the screen. The screen will automatically dim after 2 minutes of inactivity. - 5 -

6. TUNING KNOB: Rotating this control drives a precision decoder that selects the desired frequency. When fine-tuning manually you must turn the knob slowly as the decoder is very precise. 7. METER: The left hand meter displays signal strength. The higher the number the better the performance. The right hand meter displays center tune, optimum operating position will be in the middle. 8. FREQUENCY DISPLAY: Displays the frequency that you are tuned to. 9. SELECTOR KNOB: this knob selects which mode the MD 109 is operating in. When used as a tuner, FM will be shown on the left side of the screen. When other sources are added to the MD 109, the knob will be turned to activate the input for that source. IMAGE OF MD-109 FRONT PANEL Signal Strength LCD Touch Panel Center Tune FM 91.1 SIGNAL STRENGTH CENTER TUNE Selector Tuning Dial - 6 -

INSTALLING THE MD 109 1. Position the tuner the shortest distance from your preamplifier. Avoid putting the unit where there are extremes in temperature. 2. Make sure that the MD 109, with specially designed feet using Vibrapod isolators, is safely positioned on a shelf designed to hold at least 60 pounds (26.55 Kg) 3. Remove the AC cord from the pouch on the lid of the carrying case and plug it into the AC receptacle at the rear of the unit. DO NOT PLUG THE CORD INTO THE WALL POWER SOURCE AT THIS POINT. 4. Connect the tuner to your preamplifier using a set of cables consistent with the caliber and type (balanced or unbalanced) of your system. Select the tuner input on your preamplifier. Note: Be sure that the preamplifier is set to zero. 5. Connect the FM antenna and/or cable to the RF input on the back of the unit. 6. CHECK TO MAKE SURE THE UNIT IS SET UP FOR THE PROPER VOLTAGE (check for unit s voltage marked on rear panel) then plug the tuner s AC power cord into an AC power source. Be sure to use a continuous power source so as to allow the stand-by mode feature to function properly. The tuner s audio output is muted in the stand-by mode. 7. The power switch on the rear of the unit must be put in the on position 8. When power is supplied the screen will be black. To turn on the touch screen, touch it anywhere on the Magnum Dynalab logo, at which time the Magnum Dynalab logo and the word power will be displayed. - 7 -

9. To turn on the unit push the power button. At first the screen will display warming up as the components are brought up to a safe operating condition. Once the safe operating condition is attained, the screen that is associated with the setting of the input knob will appear. If you are using it in the FM tuner mode, FM will appear on the left side of the screen. Note: Each time the tuner is turned ON, there is a 25 second delay before the tuner will operate. A light click will be heard, indicating that the relay has been activated and that power is available. WARMING UP... 10. Once power has been initialized, the meters will light and the touch screen will show a reading between 87.5 and 108.5. All control functions will appear on the bottom of the screen and the default positions will show on the top right corner. a. Turn off the Mute switch b. Set the Band switch to wide - 8 -

PRESET 03 FM TUNER STEREO SUPER NARROW BLEND MUTE MONO NARROW / WIDE 99.1 MHz PRE POWER STEREO BAND BLEND MUTE DIM Extra Text 11. To tune the tuner you have three options: a. Use the tuning knob on the right b. Use the tune up or down arrow with the MHz position displayed on touch screen c. Use the remote control using the tune up and down buttons 12. The tuner is now in a safe operating mode. 13. To turn the MD 109 off push the power button on the screen, the screen will become dark. To turn on the screen, touch the Magnum Dynalab logo or turn the right hand knob. - 9 -

PROGRAMMING THE TOUCH SCREEN The touch screen is designed to last 10,000 hours. Once the unit has been turned on and the touch screen has been activated it will be at full brightness. After two minutes of inactivity (no touching) the screen will go into a sleep mode, this sleep mode (50 % brightness) will lengthen the life of the screen. To activate the screen touch any point on the Magnum Dynalab logo, use the remote hand held or turn the right hand knob (tuning dial). Cleaning the touch screen: Only use a very soft cloth (eyeglass cleaning cloth) with a non-abrasive cleaner. SETTING THE FM PRESETS FROM THE TOUCH SCREEN 1. With the screen displaying the FM frequency, touch the digits, a new screen will appear depicting the preset grid. PRESET 03 FM TUNER STEREO SUPER NARROW BLEND MUTE MONO NARROW / WIDE 1 2 3 4 5 6 7 8 9 99.1 MHz PRE S 0 P POWER STEREO BAND BLEND MUTE DIM Extra Text 2. Tune to the station you wish to store, push the S button on the display and then the preset location, you must use two numbers i.e.: 01. You must also do this fairly quickly to insure storage. Repeat this procedure for up to 40 preset locations. 3. To scan the presets, push the button showing MHz, it will change to pre if you push the up arrow above it you will scan your presets going up, by pushing the down button you will view the ones below. To return to MHz, push the pre button. 4. To return to the main screen touch any point on the screen. - 10 -

LAYOUT REAR PANEL INPUTS: All inputs are electrically isolated from the chassis to insure that the ground plane is not compromised. The MD 109 is equipped with two module windows, these windows will be replaced if a DAC or an alternative source is added to the MD 109. When another source is added to the unit the software will sense this new device and setup the touch screen accordingly. This new input will be recognized when the left hand knob is set to the input description i.e.: D1, D2, satellite radio or HD radio or whatever future digital sources are connected. OUTPUTS: The MD 109 uses high grade Neutrix, XLR connectors for balanced output in a fully balanced system. Unbalanced output is handled using precision manufactured WBT RCA connectors. POWER INPUT: Plug in the AC cord, insuring that the voltage marked on the rear of the unit is the same as the source AC. This receptacle also holds the external fuse as well as the on/off switch. ANTENNA INPUT: Hook up the antenna lead to this connection. - 11 -

RECEPTION TECHNIQUES Antenna Cabling: The lead-in cable from the antenna is often the weakest link in the FM system. Some time spent on selection and matching will yield dramatic results when it comes to noise reduction in weak signals. A good grade of 75-ohm coaxial cable will provide very sufficient signal passage, along with effective shielding against interference. Without effective shielding your coaxial cable can in fact become an antenna in itself. There are different grades of 75-ohm cable, RG59/U (Suitable for 50 feet and less) and RG 6. RG 6 is the better of the two and should be used in runs of 50 feet or more. The RG 6 has quad shielding and 50 % less losses than RG 59/U. A good type of RG 6 is Beldon 1189 A. Combine this cable with LRC connectors and you will have an installation that will optimize the performance of your tuner. The key to maximizing the efficiency of the system is insuring that all connections are clean and tight, silicon grease on outdoor connections will insure good performance over a long period of time. If you splice either cable, make sure that exactly the same type of cable is used. Types of Antennas: Multi-element Yagi - This is a unidirectional antenna capable of pulling in very distant stations due to its high gain. The higher the gain the better. These types of antennas are directional and should be used with a rotor to get the maximum benefit from the antenna. The directional feature helps eliminate multi-path problems by allowing only the signal from the direction that the antenna is facing to be picked up by the antenna and not the signals that come from different directions. Magnum Dynalab offers two Yagi antennae, the MD 6 FM or MD 10 FM Vertical ½ Wave - This design offers ease of installation and operation. This type of antenna is omni-directional, which means that it picks up stations coming from all directions. No rotor is required to pull in stations from behind or the side. This design also gathers more of the FM signal from the air, offering superior fidelity over that of a standard bi-directional antenna. It also gives 2.5 db gain to the signal strength over that of a standard dipole. If multi-path is a reception problem, try laying the antenna down in the horizontal plane rather than the vertical plane. This type of antenna can be used indoors or - 12 -

outdoors, but regardless of whether it is installed indoors or outdoors, the higher that you can put it the better it will perform. Magnum Dynalab offers the MD ST-2, an excellent vertical ½ wave antenna Folded Di-Pole - This is the most common and simplest of all antennas; most people are familiar with the folded di-pole you received with most electronics gear (generally provided with a tuner or receiver). This piece of wire is bi-directional and the performance of it is affected by the angle that the signal hits the piece of wire. There are quite a number of di-pole antenna designs; they work well in areas of strong signal strength. Magnum Dynalab offers the SR-100 as an excellent, indoor folded di-pole. There are many styles of antennas but all of them are based on one of these types. FM RECEPTION AIDS AND ACCESSORIES We have already alluded to the importance of a good quality antenna which has been designed and built with the reception of the FM bandwidth exclusively. Should you encounter a situation in which you require more gain to the FM signal or situations where you may need less gain AND better selectivity then the Magnum Dynalab 205 Signal Sleuth may be of benefit to you. The 205 is a FM signal processor/amplifier designed specifically for FM. If you would like more information on this item, please feel free to contact us at any time. Call us TOLL FREE 1-800-551-4130, email us at info@magnumdynalab.com or visit us at www.magnumdynalab.com. - 13 -

OPERATING THE CONTROL SYSTEM USING THE HANDHELD 1. To turn on the power push the on button, to turn the power off push the off button 2. To tune up and down push the tune up and tune down buttons 3. To directly access a station, push the numbers representing the frequency of the station. 4. To store presets: a) Tune the station frequency you want to store, make sure you are tuned perfectly tuned to the station (as indicated by the center tune meter). b) Push store and then the preset location, must be two digits, i.e.: 01 c) Repeat steps 1 & 2 for other presets d) To recall a preset, you can push the preset button and the number of the preset you want. e) To reset or purge the presets press p then s within 5 seconds. Problem Probable Cause Probable Solution Presets will not store Speed of entry of preset When entering the preset position too slow location do it fairly quickly Distance that the Batteries are weak Change the batteries remote will work is Three AAA very short Tuner will not turn on AC not connected The infra red sensor is blocked Check power cord Remove anything sitting in front of the unit - 14 -

- 15 - IMAGE OF RC2 REMOTE

TROUBLESHOOTING PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION No sound, meter lights are not on No sound, meter lights are on Signal strength is low Power cord disconnected Power off at source Fuse blown Interconnect not properly installed Preamp set to wrong source Power amp off Tube failure Antenna not connected Wrong type of antenna Station too far away Antenna pointed the wrong way Reception is poor Antenna not connected Wrong type of antenna Cross talk from neighboring stations Multi-path is occurring Connect power cord Check AC source Check fuse in AC input socket Check installation of interconnects Turn preamp to appropriate input Turn on amp Replace tubes (6922) Check antenna hookup Check instruction manual for types of antennas Change your antenna Rotate the antenna to point at the station Check antenna hookup Check instruction manual for types of antennas Switch to narrow setting on IF bandwidth Rotate your antenna, read the Reception Techniques Intermittent sound Mute switch is off Turn mute switch on - 16 -

SPECIFICATIONS Usable sensitivity- Mono 0.7 u V 9.0 dbf 50 db quieting Mono 2.0 u V 9.9 dbf 50 db quieting Stereo 2.3 u V 20.0 dbf Capture ratio 1.5 db Image rejection 125.0 db Signal to noise ratio 80.0 db Alternate channel Wide 46.0 db Alternate channel Narrow - 70.0 db Alternate channel Attenuation ~ super narrow 80.0 db Adjacent channel Wide 3.0 db Adjacent channel Narrow - 21.0 db Adjacent channel Super Narrow 48.0 db THD Mono 0.10 % THD Stereo 0.10 % Stereo separation 50.0 db AM suppression 70.0 db SCA rejection 80.0 db IF rejection 80.0 db 19 KHz and 38 KHz component rejection 75.0 db Audio frequency response 2 Hz to 200 Khz( +0,-0.1 db) Balanced audio output (600 ohms) 2.0 V Line audio output (RCA) 1.0 V Output Impedance 200 ohms ( 2Hz-200KHz) Signal to noise ratio >110 db Fuse replacement 115 volts 1 amp Fuse replacement 230/240 volts.5 amp Tube replacement ( position 1 & 2) 6922 MD Cryovalve Refrence Tube replacement ( position 3 & 4) 6922 MD Reference Line power (Must be specified) 110/220/230/240 - VAC Dimensions (inches H.W.D.) 6 x 19 x 16 Dimensions (cm H.W.D.) 15.24 x 48.3 x 40.7 Weight (lbs./kgs) - 40/17.1 Power consumption (Typ/Max) 50w/100w MAGNUM DYNALAB LTD. RESERVES THE RIGHT TO CHANGE OR MODIFY THE SPECIFICATIONS WITHOUT FURTHER NOTICE. - 17 -

SAFETY SHEET IMPORTANT SAFETY INSTRUCTIONS 1. KEEP THESE INSTRUCTIONS 2. HEED ALL WARNINGS 3. FOLLOW ALL INSTRUCTIONS 4. DO NOT USE THIS APPARATUS IN WATER 5. CLEAN ONLY WITH DRY CLOTH 6. DO NOT BLOCK ANY VENTILATION OPENINGS, INSTALL IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS. 7. DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS RADIATORS, HEAT REGISTERS, STOVES, OR OTHER APPARATUS (INCLUDING AMPLIFIERS) THAT PRODUCE HEAT. 8. DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDING TYPE PLUG. THE GROUNDING PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG. THE THIRD PRONG IS PROVIDED FOR YOUR SAFETY. IF THE PROVIDED PLUG DOES NOT FIT INTO YOUR OUTLET, CONSULT AN ELECTRICIAN FOR REPLACEMENT OF THE OBSOLETE OUTLET. 9. PROTECT THE POWER CORD FROM BEING WALKED ON OR PINCHED PARTICULARLY AT PLUGS, CONVENIENCE RECEPTACLES, AND THE POINT WHERE THEY EXIT FROM THE APPARATUS. 10. ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE MANUFACTURER. 11. UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME. 12. REFER ALL SERVICING TO QUALIFIED PERSONNEL. SERVICING IS REQUIRED WHEN THE APPARATUS HAS BEEN DAMAGED IN ANY WAY, SUCH AS THE POWER SUPPLY CORD OR PLUG IS DAMAGED, LIQUID HAS BEEN SPILLED OR OBJECTS HAVE FALLEN INTO THE APPARATUS, THE APPARATUS HAS BEEN EXPOSED TO RAIN OR MOISTURE, DOES NOT OPERATE NORMALLY, OR HAS BEEN DROPPED. 13. THE EQUIPMENT REQUIRES A GROUNDED POWER OUTLET TO OPERATE SAFELY. 14. THE POWER SUPPLY CORD IS THE MAIN DISCONNECT AND SHALL BE READILY OPERABLE. WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. - 18 -

LIMITED WARRANTY Register your product at www.magnumdynalab.com Magnum Dynalab Ltd. herein referred to as the manufacturer guarantees this product to be free of defect in both material and workmanship and agrees to remedy any such defect or replace any defective component at no charge for a period of two years from date of sale to the first end user. This warranty is void if the product has been found to be subjected to misuse, abuse, lightning strike, unauthorized service, damaged in transit or has been altered or repaired in such a way as to detract from its performance, reliability or its safe operation. All tubes are covered for 12 months. Should such defect be discovered and it falls within the terms of this guarantee, the manufacturer will correct the defect in workmanship and/or replace any defective component with a new one of similar capability and value. This warranty does not apply to the cabinet or appearance items such as the faceplate, control knobs or meter lenses nor does it cover any expenses in shipping the unit to the appropriate service depot. The foregoing is in lieu of any other warranties expressed, implied or statutory and the manufacturer neither assumes nor authorizes any person to assume for it any other obligation or liability in the connection with the sale of this product. This warranty is not transferable except by written authorization from the manufacturer. In order to qualify under the terms of the above warranty, all items must be returned to the appropriate factory service depot with all shipping charges prepaid in lieu of having previously registered the purchase of the unit by completing and returning the attached Registration Card, the unit must be accompanied by proof from an authorized Magnum Dynalab Ltd. dealer. YOUR LOCATION Within the USA Within Canada Other Countries RETURN SHIPPING ADDRESS Magnum Dynalab c/o Trans American 2775 Broadway, Buffalo, NY, USA 14227-1043 PHONE: 1-800-551-4130 Magnum Dynalab Ltd. 8 Strathearn Avenue, Unit # 9 Brampton, ON, Canada L6T 4L9 PHONE: 1-800-551-4130 Contact selling dealer TO PREVENT FIRE SHOCK OR HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER OR FACEPLATE, NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. - 19 -