Crimp & Cleave Termination Instructions for SEL ST Connectors

Similar documents
Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Service Call: Fiber Optic Installation and Repair

HCS - HES Cabling Systems

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

Instructions. Cable with Armor F CAUTION. October Rev A

Water blocking tape. Locator ridge HPA-0486

Medium Box for Cable Termination

3M Better Buried Compound Compression Closure System

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Buffer Tube Midspan Access Tool Accessing fibers in buffer tube procedure

In-Wall Control Mount for ipod Touch

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

3M Fiber Optic Wall Mount Enclosure 8430 Series

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

TECHNICAL GUIDELINE. Universal/Toneable FTTP Cable Applications Guideline. Materials Required

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

3M Distribution Box (DDB)

OCT 15 Rev B

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Optical Distribution Box 300 Installation Guide. Version : R0.0

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

E2O6CMRXP-1T9 drop fiber leg preparation

INSTALLATION INSTRUCTIONS

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

LCC (Little Coaxial Connector) Installation Instructions)

3M No Polish Jacketed SC/APC Connector

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

Quick Release Roof-Mount Kit MB700

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Panduit Recommended Best Case Practice Split Fibre

K-LWLH1 2.0 m AA. K-LWLH m AA. K-LWLH m AA

FOSC 450 C6 and D6 Closures

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M Better Buried Closures

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

2178-L/S Series Fiber Optic Splice Case with Gasket

3M Cold Shrink Splice Kit QS-III 5515A

3M Cold Shrink Splice Kit QS-III 5416A

Table 4-1: Rating Levels

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

SECTION 4 TABLE OF CONTENTS

IP-LINX. Installation Guide

3M Cold Shrink Splice Kit QS-III 5514A

User's Guide to the PROLITE-30B

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

Caution. Hanging the Screen:

Folding Beauty Dish INSTRUCTIONS

27mm ECAM Double Cable Entry Port

IP-LINX Fiber :: X-XXXX

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

3M Coupling Tray FDTC-10S-COUPLINGTRAY

Industrial Loadbreak Elbow

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

TECHNICAL GUIDE. TOUGH GUN ThruArm G1 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-12, 100iC-6L, 100iC-7L, 120iC, 120iC-10L, 120iC-12L

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

Gel-sealed in-line fiber optic closure

18mm ECAM Cable Entry Port

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

TO THE INSTALLER: BE SURE TO LEAVE THIS MANUAL WITH THE OWNER.

Instrument Care. Band. Instruction Pack. Print and hand out! Instruments:

TECHNICAL GUIDE. TOUGH GUN ThruArm G2 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-6L, 120iC, 120iC-10L INSTALLATION MAINTENANCE

Fiber Optic Product Overview

3 SLiC Aerial Closure with Rubber End Seal

PRODUCT MANUAL. Product Description. Product Features. Manual will Review. LED Mini Neon 80W 24V DC. LED Mini Neon 80W 24V DC

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Multi-Media Installation Guide

S183PM2 ver. 2 / S184PM-SLDF ver 2.

Public Works Division Lighting District Fiber Optic Specifications April 2009

3M No Polish Jacketed SC/APC Connector

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

Cold Shrink Straight Joint

MCX Miniature Coaxial Connectors

3M 8900 Single-mode SC Crimplok Connector

Fiber Optics Redefined

TE Connectivity DEUTSCH DL Series MIL-DTL Series III Connectors

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Building a MidiBox LCD Cable

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

SLiC Fiber Aerial Closure System

Ultra-Grip Crimp Connector Hand Tool Kit for Coaxial Cable and Powerpole Connectors

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

Fiber ICT. Optical Fiber Catalogue

Part Number (used with PRO-CRIMPER Tool Frame ) for 50 Ohm BNC Dual Crimp MIL Type Connectors

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

Viztrac AM200 User s Guide. Page 1 of 12

VITALink Taped Splice Straight Through Crimp

Transcription:

Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for SEL ST Connectors For Use With: ST Termination Kit (SEL, Part Number BT05402-01) 200 µm HCS Fiber-Optic Cable ST Crimp & Cleave Connectors

Important Safety and Warranty Information Please Read First Please make sure to READ and understand termination instructions completely. Improper assembly will cause poor termination results and cause damage to termination kit components. Make sure you WEAR eye protection during the cleaving process. The bare fiber is sharp and may splinter; handle very carefully. Make sure fiber is disposed of properly, in a hardsided container. OFS recommends that all replacements or repairs be made at our manufacturing facility, except where specifically outlined. Please CONTACT the sales representative in your region or call the factory for technical support: Mon-Friday, 8:00 am-5:00 pm EST. 888-438-9936 [Toll free in the US and Canada] 860-678-0371 [International] OFS WARRANTS this termination kit to be free of defects for a period of 90 days from the date of purchase. Each kit is qualified at our factory prior to shipment. OFS will, at their discretion, repair or replace any tools found to be defective due to workmanship within the stated warranty period. (Excludes damage to the fiber stripper, cleave tool, and/or diamond blade due to misuse.) 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com i

ii Table of Contents Content Page Content Page SEL ST Termination Kit Contents....1 Related Products and Accessories.... 2-3 ST Connectors...2 Termination Instructions Step 1: Strip cable outer jacket...3 Step 2: Install strain relief boot...6 Step 3: Strip fiber buffer...6 Step 4: Install cable anchor...8 Step 5: Install crimp sleeve...9 Step 6: Install ferrule...10 Step 7: Crimp ferrule...11 Step 8: Cleave fiber...13 Step 9: Position strain relief boot... 16 Maintenance & Trouble Shooting Guide Importance of Cleave Tool Cleaning and Maintenance...17 Cleave Tool Cleaning Kit...17 Diamond Blade Replacement Kit...17 Trouble Shooting Guide...18 Termination and Test Kits Available...19 Trademark Information... Back Cover Diamond Cleave Tool Diagram...13

SEL ST Termination Kit Contents Contents Part Numbers Description Diamond Cleave Tool Cable Stripper BT05402-01...SEL ST Termination Kit AP04244-02...SEL ST Instruction Booklet DT03732-06...ST Diamond Cleave Tool (Green Spring) Crimp Tool AP01224....Cable Stripper BT03865-03...Crimp Tool (Red Handles) CP01229-02... Fiber Stripper (White Insert) AP01224....Scissors K16248... Booklet: Importance of Cleave Tool Cleaning and Maintenance Scissors Fiber Stripper Other Items Required (not included in kit): Safety Glasses, Marker Final Assembly Prong Tool Brush 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 1

2 Related Products and Accessories Sold Separately Part Numbers Description AT03290....Diamond Blade Replacement Kit ST Connectors (Sold Separately) Part Numbers Description BP05065-11...ST Connectors for 1.8 mm (Bag of 25) ST Connector Subcomponents End Cap ST Ferrule BP05065-12...ST Connectors for 2.2 mm (Bag of 25) BP05065-13...ST Connectors for 2.5 mm (Bag of 25) BP05065-14...ST Connectors for 3.0 mm (Bag of 25) ST Connector Components Strain Relief Boot Cable Anchor Crimp Sleeve ST Ferrule End Cap AP01960....ST Splice Bushing Crimp Sleeve Cable Anchor Strain Relief Boot

Termination Instructions STEP 1 Strip Cable Outer Jacket Zipcord Cable (FZ) a. Mark cable outer jacket 6 inches from the end of the cable with a marker. b. Initiate a cut between the two branches of cable and carefully pull the two ends apart approximately 6 inches (to the mark) from the end of the cable. NOTE: C800FX/FDST have 200 µm ST connectors (SEL #090-5001). NOTE: Make sure the cable has no kinks or sharp bends. c. Mark cable outer jacket 2 1/2 inches from the end with a marker. d. Select the 1.0 cutting hole on the cable stripper. Step 1 continues onto the next page 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 3

4 Termination Instructions STEP 1 Strip Cable Outer Jacket Zipcord Cable (FZ) continued e. Using the cable stripper, apply quick squeezing action, release and remove the 2 1/2 inches of cable outer jacket. NOTE: If cable outer jacket is difficult to remove in one step, it may be removed in shorter sections. 0 1 /2 1 1 1 /2 2 2 1 /2 3 25 mm 50 mm 63 mm 76 mm 2 3 /16 55.5 mm f. Verify proper strip length against the Strip Template, shown below. g. Repeat steps a thru f on the second branch of cable.

2-Channel Cable (FD) a. Mark cable outer jacket 8 1/2 inches from the end of the cable with a marker. b. Cut back the cable outer jacket to the 8 1/2 mark. c. Apply a 1 1/2 inch section of 3/8 inch heat shrink over the cable outer jacket, overlapping inner cables by 1/2 inch. d. Mark inner cables and cable outer jacket, 2 1/2 inches from the end with a marker. e. Select the 1.0 cutting hole on the cable stripper. f. Using the cable jacket strip tool, apply quick squeezing action, release and remove the 2 1/2 inches of cable outer jacket. g. Verify proper strip length against the Strip Template, shown on page 4. NOTE: If cable outer jacket is difficult to remove in one step, it may be removed in shorter sections. h. Repeat steps a thru g on the second inner cable. 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 5

Termination Instructions 6 STEP 2 Install Strain Relief Boot Slide strain relief boot (tapered end first) onto cable and move up out of the way for easy stripping. NOTE: The tapered end of the boot may be trimmed with scissors to suit larger diameter cables. STEP 3 Strip Fiber Buffer! Before you start: Make sure to use the appropriate strip tool insert for the buffer removal process: 200 µm = WHITE. Careful while handling the FIBER STRIPPER. Handle as a precision device and do not strike on hard surfaces or drop. Clean blades frequently using small bristle brush supplied. Pull straight when stripping the fiber buffer. This is important in order to avoid damage to the HCS cladding.

a. Insert buffered fiber through guide tube of the fiber buffer strip tool until the cable outer jacket bottoms out in the tube. b. Holding cable securely, squeeze handles to cut buffer and PULL STRAIGHT to remove buffer. Inspect HCS cladding for damage from improper buffer stripping. (i.e. white dusty stripe) NOTE: If unable to insert buffered fiber through guide tube, trim tip of the fiber using scissors. If a short length of cable is being terminated, wrap the cable around your finger to prevent fiber and aramid yarn from pulling out of cable jacket. c. Less than 5/16 inch of buffer should be exposed. d. Verify proper buffer strip length to be approximately 2 3/16 inches. e. Repeat for the second cable. NOTE: Be careful not to touch the HCS fiber coating. Once the fiber has been stripped, the coating will retain finger oils, which can transfer to and damage gripper pads in the cleaver during step 8 in the termination process. 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 7

8 Termination Instructions STEP 4 Install Cable Anchor a. Slide anchor, large end first, onto the fiber and push completely down onto the cable. Bottom out the anchor on the cable outer jacket using a clockwise turning motion. (i.e. screw the anchor onto the cable outer jacket). NOTE: Be careful not to touch the HCS fiber coating once the fiber has been stripped. The coating will retain finger oils which can transfer to and damage the gripper pads in the cleaver during Step 8 in the termination process. b. Position anchor in crimp tool such that end of anchor aligns with edge of crimp die. c. Squeeze crimp tool handles together until it clicks, then releases. d. Repeat for the second cable.

STEP 5 Install Crimp Sleeve a. Slide the crimp sleeve over the cable anchor until it bottoms out on the cable anchor. b. Position the crimp sleeve in crimp tool such that the back edge of the crimp sleeve is aligned with the edge of the crimp nest. c. Squeeze the crimp tool together until it clicks, then releases. d. Repeat for the second cable. 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 9

Termination Instructions 10 STEP 6 Install Ferrule a. Feed the fiber through hole in rear of the ferrule. b. Slide the ferrule for the ST connector down the fiber and into the crimp sleeve. Push the ferrule firmly until it bottoms out in the crimp sleeve. c. Repeat for the second cable.

STEP 7 Crimp Ferrule! Before you start: Make sure the ferrule is fully seated in the crimp sleeve. Check to make sure the crimp die is stamped properly for the connector type, ST facing to the right. Proper positioning of the connector in the die set is critical for proper crimp location. Failure to crimp in the prescribed location will result in poor connector retention strength. Crimp dies can be reversed at the factory for left-handed operators. ST Connector a. Position the back of the ST coupling nut against the side of the crimp die set stamped ST, as shown. Step 7 continues onto the next page 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 11

12 Termination Instructions STEP 7 Crimp Ferrule continued a. Rotate ST connector so that its key is oriented in the crimp die as shown. Keyway b. Squeeze the crimp tool handles together until the tool releases. c. Repeat for the second cable.

STEP 8 Cleave Fiber! Before you start: Make sure the appropriate cleave tool positioner plate is being used: ST Make sure the appropriate colored tension spring is being used: 200 µm = GREEN Refer to diagram of the Cleave Tool. Careful while handling the Cleave Tool. Handle as a precision device and do not strike on hard surfaces or drop. Keep the cleave tool clean and free from oils, including naturally occuring finger oils. Gripper pads, diamond blade and anvil should be cleaned after every 50 cleaves. Use the OFS Cleave Tool Cleaning Kit Part #P16247 - available separately. Do not use alcohol to clean the diamond blade or the gripper pads. Alcohol will chemically react with the gripper pads and ruin them. Do not insert metal tools near the diamond blade, as it is fragile and may chip. Trigger Positioner Plate Tension Spring Gripper Pads Diamond Blade & Anvil Housing 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 13

14 Termination Instructions STEP 8 Cleave Fiber continued a. Holding the CLEAVE TOOL in a horizontal position, grip the handle while leaving your index finger free to actuate trigger. NOTE: It is critical to fully insert the connector into the positioner plate. Failure to do so, may cause poor cleave quality and/or damage to the diamond blade. b. Place the ferrule into the hole of the positioner plate until it is fully inserted. c. Release the connector in the tool. d. Using your index finger, SLOWLY and GENTLY depress the trigger to perform the cleave process. The cleave process is complete when the fiber snaps away from the connector. (Do not release the trigger!). NOTE: It is critical to fully insert the connector into the positioner plate. Failure to do so, may cause poor cleave quality and/or damage to the diamond blade. NOTE: Do not hold onto the connector during the cleave process. Doing so may cause poor cleave quality.

e. Before releasing the trigger, remove the connector from the cleave tool and grasp the top of the scrap fiber while releasing the trigger. Gently remove the scrap fiber while keeping it away from the diamond blade. f. Dispose of scrap fiber safely in a hard-sided container. g. Install protective cap onto connector to protect cleaved fiber surface. h. Repeat for the second cable. 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 15

16 Termination Instructions STEP 9 Position Strain Relief Boot a. Slide strain relief boot onto connector (up to the rear of the coupling nut) to complete termination.

Maintenance & Trouble Shooting Guide Importance of Cleave Tool Cleaning and Maintenance The Cleave Tool supplied with OFS s Termination Kits contains movable parts, wear items, and a diamond blade that require regular maintenance, care, or replacement after useful life in order to perform satisfactorily. Damage and parts replacement expense can result if recommended procedures are not followed. ~ The diamond blade must be cleaned; the gripper pads must be cleaned, kept oil-free, and replaced after wear. ~ The cleave-tool trigger must be depressed slowly. Cleave Tool Cleaning Kit For cleaning your cleave tool, please order the OFS Cleave Tool Cleaning Kit (part #P16247) which includes recommended cleaning fluid, swabs, and complete instructions. Diamond Blade Replacement Kit For replacing the diamond blade/anvil assembly, please order the Diamond Blade Replacement Kit (Part #AT03290.) The kit includes a new diamond blade, anvil, replacement screws, and complete instructions for performing this simple procedure at your facility. Trouble Shooting Guide 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 17

18 Trouble Shooting Guide Problem Dim-light termination/ no light termination Poor cleave quality / High insertion loss Fiber does not cleave Fiber protrudes or recesses after cleave Possible Explanations Improper strip technique Refer to Steps 2 & 3 Improper crimp position Refer to Steps 4-7 Improper crimp position Refer to Steps 4-7 Improper cleave techniques Refer to Step 8 Incorrect tooling for fiber size or connector type Refer to Page 1 Diamond blade needs to be cleaned or replaced Refer to Page 20 Gripper pads worn and need to be replaced Call Tech Support to place a purchase order for service. Fiber has not been first thoroughly stripped Refer to Step 3 Improper cleave techniques Refer to Step 8 Incorrect tooling for fiber size or connector type Refer to Page 1 Diamond blade needs to be cleaned or replaced Refer to Page 20 Gripper pads worn and need to be replaced Call Tech Support to place a purchase order for service. Improper crimp position Refer to Steps 4-7 Improper cleave techniques Refer to Step 8 Incorrect tooling for fiber size or connector type Refer to Page 1 Gripper pads worn and need to be replaced Call Tech Support to place a purchase order for service.

Termination and Test Kits Available OFS offers a specialized Termination Kit and associated Insertion Loss Test Kit for each type of Crimp & Cleave connector we support. These kits are available in various combinations of sizes and/or connector types. Customer Relations at our factory can help you select the correct kit for your purposes. 888 438 9936 (US & Canada) or 860 678 0371 www.ofsoptics.com 19

This document is for informational purposes only and is not intended to modify or supplement any OFS warranties or specifications relating to any of its products and services. Copyright 2014 OFS Fitel, LLC. All Rights Reserved. 0814 Trademark Information: Manufactured in the USA by OFS. HCS is a registered trademark in the USA of OFS Fitel, LLC. 55 Darling Drive, Avon, CT 06001 To learn more, please call or visit our website. Phone: 1 860 678 0371 Toll Free: 1 888 438 9936 Web: www.ofsoptics.com AP04244-02 Rev. G