Modular Junction Box MJB with Gateway. Data sheet LINAK.COM/MEDLINE-CARELINE

Similar documents
POWER MOLE SERIES DA GAO RGBT RADIX

COLOR POWER SERIES DA CL9 VEGA

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Lift systems for your flat screen

FLEXIBLE SERIES DA LR WW LENTUS

IP Roombox. Hotel Room Management

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

ARS x4 MATRIX SWITCHER Instruction Manual

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

M203 LG. Multiroom Planer V2.00. Introduction. New features from software V2.00

Single Point Flow Monitor SW118 SW119

Capacitance Limit Detection nivotester FTC 420/421/422

Lt DELTA USA, Inc

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Process transmitter RMA422

Operating room monitor Medical-grade 4K UHD monitor

LCS2 Cat. 6 RJ 45 Patch panels and units

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

DATA SHEET Panorama Rudder Indicator, TRI-2

VNS2200 Amplifier & Controller Installation Guide

Chapter Medical Table of Contents

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

of Loewe E 2.10_m1 1

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

SIMATRIX NEO V2 Modular Video Matrix

DALI TOUCHPANEL BASIC TW. Operating and control unit

High performance circuit breakers

PART 1: HARDWARE. Author: Vandermeerschen M. Version

Ordering details. Approval. Classification

POWER LINE BAR SERIES DA PL6 WW NORA

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Nessie Coils for VDH and VDHT valves

DVB-LR10. Compatible with Land Rover touch-screen navigation systems version 2

KACO-display. Wireless Solar Monitoring System. Operating Instructions KACO-display. full of energy...

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

HDMI over Wireless Extender - 65 ft. (20 m) p

HIGH FREQUENCY TWIN AIR GAP TRANSMISSION SYSTEM

Video Micro Converter

Display Information Type Backlit blue on white STN Type

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

Technical data. General specifications. Indicators/operating means

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

KRF EMC Filters Installation, Operation and Maintenance Manual

CSA x2 Alarming RS-232 Seq. Video Switcher. Instruction Manual

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

OWNER S MANUAL. Model 861 Hand Held Bale Scanner # REVISED 4-10

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

TFR5 Room or outdoor temperature sensor. CombiTemp TM

EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS

Audio Interface II Manual. Audio Interface II. Eurorack <-> Line Level Audio Interface. Manual Revision:

DT1-PCM21. for Porsche PCM2.1 navigation systems

Goodmans Helpline Phone Number

DT1-LR10. Compatible with Land Rover touch-screen navigation systems version 2

4-in-1 Motor Controller CAN

STORQ System Installation Guide

The Haply Development Kit

ex 800 Series ematrix System

Photoelectrics Through-beam Type PA18C.T..., DC

Wireless HD Video Link

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Outdoor Pixel-Router. User Guide

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

OEM Version. 1.0 INTRODUCTION Retail Version: Includes reader, USB cable and five peel & stick RFID tags

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

02/11/2015

Datasheet - SRB301LC 24VAC/DC

of of Re:connect M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03

CAT6 Cable Tester. Operating Manual. Part No TRIAX - your ultimate connection

S6-R READER. Installation and Operating Instructions

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

PRINCIPLES AND APPLICATIONS

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Prism TM450 Installation Guide For JBus 1708 and 1939

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Electronic converter for level transmitters MT03L Instructions manual

MX194. Your advantages. 1MP Medical-Display

HiTECH Technologies, Inc.

Light Curtain Type LA

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

PRODUCT NO.: PT-L6600L/L6510L PRODUCT NAME: BriteOptic LCD Projectors

Quick Start Guide. Wireless TV Connection with Dongle. GWHDKITD PART NO. Q1504-b

Type Contact form Model

TED Pro Energy Monitoring and Control System

User Guide. Centrex Recording Interface

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DisplayPort Signal Booster - DP Extender - 4K 60Hz

Safety Light Curtains GuardShield

Set Up Your OTA Antenna & Dual-Tuner OTA Adapter

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Transcription:

Modular Junction Box MJB with Gateway Data sheet LINAK.COM/MEDLINE-CARELINE

MJB The MJB Modular Junction Box is designed for use together with OpenBus control boxes. The MJB makes it possible to connect multiple handsets, attendant controls or it is also possible to use the MJB as a control unit for such as USB charger, Under Bed Light and 3 rd party products. MJB - GATEWAY version, 504-010 & 504-020: The MJB is a simple gateway interface, which can connect switch input notifications from the infrastructure of the hospital or nursing home, such as service/nurse call systems. Please note that notifications are only to be used as service information and not for emergency issues. For more info about Standard functionality, please see on page 3 Features: Add-on value for hospital & care application Compact and functional design which allows easy mounting 2 connections: Port 1 OpenBus connection / Port 5 Gateway Colour: Light grey RAL 7035 Protection class: IPX6 Connection to OpenBus control box via modular plug cable, 6 wires Modular plug to open end (cable available) Options: Customised configuration (Configuration number 100) It is possible to define the OpenBus signals to be used for activating the relays and / or change the notification indicator, so that it fits to the customers system. Please contact your Sales Engineer at LINAK A/S for further information. Usage: Compatible with all LINAK OpenBus control boxes, light & full Contact rating : Max continuous current: = 1A Max switching voltage: = 48 V (DC) Max switching capacity: = 24 VA Contact resistance: < 100 mω Current consumption: V bus 8V : < 9 ma V permanent 40V : < 14 ma Approvals: The MJB has been approved according to IEC60601-1:2005 3 rd edition, ANSI / AAMI ES60601-1:2005, 3 rd edition, and CAN / CSA-22.2 No 60601-1:2008 LINAK.COM/MEDLINE-CARELINE

OpenBus configuration code: MJB 5 0 4 1 0 1 0-1 0 2 3 5 0 4 5 0 4 Gateway 0 1 0 DN (Device Number) 150 Relay 1, Key 1 = A31 (ID2 - Nurse Call) Relay 1, Key 2 = E31 (ID5 - Nurse Call) Relay 1, Key 3 = H31 (ID1 - Nurse Call) Relay 2, Key 1 = A29 (ID2 - Service Call) Relay 2, Key 2 = E29 (ID5 - Service Call) Relay 2, Key 3 = H29 (ID1 - Service Call) Relay 1, Status 1 = A0 (ID2 - Nurse Call) Relay 1, Status 2 = E0 (ID5 - Nurse Call) Relay 2, Status 2 = E1 (ID5 - Service Call) Please note. Relay 1 Changes state when powering up *Service Data Tool 2, can read out the special / standard code nr. and configuration Gateway 0 2 0 DN (Device Number) 150 Relay 1, Key 1 = A31 (ID2 - Nurse Call) Relay 1, Key 2 = E31 (ID5 - Nurse Call) Relay 1, Key 3 = H31 (ID1 - Nurse Call) Relay 1, Key 4 = H29 (ID1 - Service Call) Relay 1, Status 1 = A0 (ID2 - Nurse Call) Relay 1, Status 2 = E0 (ID5 - Nurse Call) Relay 2, Alarm 1 // Out of bed alarm (S2) Relay 2, Alarm 2 // Switch alarm (S1) Please note. Relay 1 Changes state when powering up Cable ordering nos.: 0964140-3000: Gateway cable, 3000 mm, modular plug open end 0964140-1375: Gateway cable, 1375 mm, modular plug open end Please note, the alignment groove is placed on the opposite site of the modular plug. This is to ensure that the cable is only being used for the Gateway MJB.

Port 5: Relay connetions Port 5 Relay 1: Relay 2: - Pin 1 - Pin 2 - Pin 3 - Pin 4 - Pin 5 - Pin 6 NC NO NC NO Port 1 OpenBus connetion Standard functionality: The MJB - Gateway consists of two relays, which are connected through Port 5 on the MJB. This can be done with the special cable 0964140 (Modular plug - Open end) There are as standard 2 configurations, 504-010 and 504-020, see description on the next pages. Relay 1: NC (normally closed) = Pin 2 + Pin 1 / NO (normally open) = Pin 2 + Pin 3 Relay 2: NC (normally closed) = Pin 5 + Pin 4 / NO (normally open) = Pin 5 + Pin 6 Relay 1 is NO when connected to mains and NC when no Mains. This means the relay is active when connected to the mains (closed loop). The closed loop principal is to ensure that an notification is sent if power is missing on the bed. When the mains is disconnected (power is missing), the relay will go from NO to NC, which will automatically result in an notification (status indicator) on the OpenBus. Relay 1 can be activated via the patient control (Key1/Key4) or the attendant control (Key2 / Key3). When a key is activated, the relay will switch state from NO to NC for 2 seconds. After 2 seconds the relay will automatically change state from NC to NO. The status of the relay is indicated on the OpenBus and can be used for switching on an LED. Relay 2 is as default NC, with or without mains, (Open Loop) Relay 2 can be activated via the patient control (Key 1) or the attendant control (Key 2 / Key 3) When the relay is activated, it will switch from NC to NO for 2 seconds. After 2 seconds the relay will automatically change state from NO to NC. The status of the relay is indicated on the OpenBus and can be used for switching on an LED. By using the variant 504-020 relay 2 will be controlled by the MJB variant 505/506 with switch input. Notification 1 = Switch input S2 / notification 2 = Switch input S1 When using this combination, it is important to have the MJB 505/506 connected to the system all the time. If it is not connected, the Gateway MJB will see it as an notification and the relay will be activated. The Gateway MJB scanning the OpenBus system every minute for an notification. Relay 1 CB power mode Notification level Relay state Mains unplugged, CB is in power down or the OpenBus is not Notification NC\* running (Clock/data is missing) On mains or battery at wake up Bed Notification \** NC No Notification NO Relay 2 CB power mode Notification level Relay state Mains unplugged or CB is in power down No notification NC On mains or battery at wake up Bed notification \** NO No notification. \* When the mains is unplugged or CB is in power down the relay will shift to NC state and generate a notification. \** Notification generated by nurse call or bed notifications. NC

Example of closed loop: 3 rd. party site Example of open loop: 3 rd. party site In this state no notification In this state no notification Dimensions:

Modular plug cable, narrow/wide alignment grooves: Modular plug with wide alignment groove To be used with LINAK products. Can be connected to all ports in the MJB, both ports with narrow and wide alignment grooves. Modular plug with narrow alignment groove To be used with 3 rd party products. Can only be connected to ports in the MJB with narrow slit. This is to prevent 3 rd party products to interfere with the OpenBus TM connections. Test device for MJB standard code no. >500: In case the system does not perform as expected due to a failure, a test device is available. The device is able to simulate the 3 rd party product, which should be connected. Please contact LINAK for further details. If you get the expected output from the MJBs it shows that it is working satisfactorily and the problem should instead be found in the 3 rd party product. Connection overview:

Bit matrix: ID 1 H-Codes MJB Device ID Config nr. Bit Bit 0-11 = LED Bit 12-31 = Activation* Bit 0-11 = LED Bit 12-31 = Activation* Bit 0-11 = LED Bit 12-31 = Activation* Gateway 150 01 Indicator Relay 1 Status 1 Indicator Relay 1 Status 2 Gateway 150 02 Indicator Relay 1 Status 1 Indicator Relay 1 Status 2 Gateway 150 01 Indicator Relay 2 Status 1 1 SMPS 4W 61 01 Indicator Error SMPS 4W 61 01 Indicator Status UBL / Switch input (S1/S2) 140 01 Indicator S1 alarm 1 6 UBL / Switch input (S1/S2) 140 01 Indicator S1 Status 1 7 UBL / Switch input (S1/S2) 140 01 Indicator S2 alarm 1 8 UBL / Switch input (S1/S2) 140 01 Indicator S2 Status 1 9 10 11 12 13 14 15 16 17 18 19 20 21 UBL / Switch input (S1/S2) 140 01 Enable/Disable S1 Key 1 (+E27) 22 UBL / Switch input (S1/S2) 140 01 Enable/Disable S2 Key 1 (+E27) 23 24 25 26 140 01 Enable/Disable S1 Key 1 (+E22) UBL / Switch input (S1/S2) 140 01 Enable/Disable S2 Key 1 (+E23) 27 UBL / Switch input (S1/S2) 140 01 Toggle UBL Key 1 Toggle UBL Key 2 UBL / Switch input (S1/S2) 141 02 Toggle UBL Key 1 Toggle UBL Key 2 28 Gateway 150 01 Activate Relay 2 Key 3 Activate Relay 2 Key 1 Activate Relay 2 Key 2 Gateway 150 02 Activate Relay 1 Key 4 29 SMPS 4W 61 01 On / Off Key 1 On / Off Key 2 Gateway 150 01 Activate Relay 1 Key 3 Activate Relay 1 Key 1 Activate Relay 1 Key 2 Gateway 150 02 Activate Relay 1 Key 3 Activate Relay 1 Key 1 Activate Relay 1 Key 2 Gateway 150 02 Activate Relay 2 S1 Gateway 150 02 Activate Relay 2 S2 ID 2 A-Codes ID 5 E-Codes 0 4 5 30 31 2 3 * Activation: bit 12-31 or via MJB505/506

Copyright LINAK 2018.01. MA M9-02-359-C. Chapter 10.16 Terms of use The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK. All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK. FOR MOUNTING INSTRUCTIONS AND GUIDANCE IN USAGE, PLEASE SEE THE RELEVANT USER S MANUALS