Test result 1. Conducted emission EN 55022: A1:2007 EA 3 passed 2. Radiated emission <1GHz (others)

Similar documents
EMC Test Report. 850 Kacena Road Hiawatha, IA 52233

CENTRE OF TESTING SERVICE INTERNATIONAL

Test Report. Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 )

FCC Report (WIFI) Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town Business Park LiShan Road, NanShan, Shenzhen, Guangdong, China

Testing. Maker Works. Applicant: Model No.: FCC ID: Jun., May to 16. Date of Test: PASS* Test Result: Signature: Authorized. this report.

Test Report. Product Name: Access Point Model No.: MS-6809 FCC ID: DoC

FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS

CHAO WEI ELECTRONICS CO., LTD. FCC REPORT CHAO WEI ELECTRONICS CO., LTD.

FCC Part 15 Subpart B Test Report. FCC PART 15 Subpart B Class B: 2014

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

FCC TEST REPORT For. ETI Solid State Lighting (Zhuhai) Ltd. LED downlight Model No.: XX

APPLICATION OF CERTIFICATION For. TTE Technology Inc. LCD TV FCC ID: W8ULE32HDE3000

TABLE OF CONTENTS 1. GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY

FCC PART 15B, CLASS B TEST REPORT. Autel Intelligent Tech. Corp., Ltd.

T E S T - R E P O R T. No for. SLG 42 MOBY Component

FCC Report. Beijing Visual World Technology Co.,Ltd.

T E S T - R E P O R T. No for PC24E-11-FC/R. RF-modem for wireless LAN. Agere Systems Nederland B.V.

FCC PART MEASUREMENT AND TEST REPORT FOR. DongGuan City FLYSKY Remote Model Co., Ltd.

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC FCC ID TEST REPORT

CONTENTS 6.2 TEST SET-UP...16

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd.

Raspberry Pi (Trading) Ltd. Raspberry Pi. dated. 9th December 2013

FCC Report (WIFI) Shenzhen SDMC Technology Co., Ltd 2AFC2-STB-1HD. * In the configuration tested, the EUT complied with the standards specified above.

Page: 1 of 15 FCC TEST REPORT. : MEGAVIEW DIGITECH LIMITED : C Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China

Test Report #: Date: January 24, 2006

FCC REPORT Q6WBT * In the configuration tested, the EUT complied with the standards specified above.

FCC Part 15B Test Report

FCC PART TEST REPORT. HHC Changzhou Corp.

Order Number : GETEC-C FCC Part 15 subpart B Test Report Number : GETEC-E Page 2 / 32 CONTENTS

Date: ESPOO Page: 1 (10) Appendices. Tyre Pressure Monitoring Device. Flextronics International Finland.

FCC TEST REPORT D-LINK CORPORATION

Page: 1 of 19 EMC TEST REPORT EN55024:1998+A2:2003

FCC Report (WIFI) Red Bear Company Limited. RedBear IoT phat 2ABXJ-PHAT-IOT

TEST REPORT. Power Spout PLT V. tested to. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

FCC REPORT. Report Reference No... : TRE R/C.: Simbans Picasso 10 Inch Tablet

FCC test report. Via Pezza Alta, 13 I Rustignè di Oderzo (TV)

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

CONTENTS 1. GENERAL INFORMATION INTRODUCTION PRODUCT INFORMATION DESCRIPTION OF TESTS CHANNEL BANDWIDTH...

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT

Sunlight Supply, Inc.

ONETECH Testing & Eval. Lab. VERIFICATION FCC RULES PARTS 2 & 15 CLASS A DIGITAL DEVICE. for AUTHORIZED. Win4NET Co., Ltd.

Sensoray. Model 819. Tests Conducted by: ElectroMagnetic Investigations, LLC. May 10, 2013

TEST REPORT. Test Report No. : UL-RPT-RP C V2.0. Date of Issue: 06 March 2018

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Report On. FCC Testing of the Pace Plc 16x4 Hybrid Gateway Cable Set Top Box COMMERCIAL-IN-CONFIDENCE

FCC PART TEST REPORT SHANGHAI MERIT TECHNOLOGY CORP.

FCC Test Report (Part 15C) WPT

TEST REPORT. Test Report No. : UL-RPT-RP JD18L V2.0. Manufacturer : Neeo AG. Model No. : 6336-BRAIN FCC ID : 2AKK7-BR633601

FCC Test Report. Color LCD Monitor

FCC Test Report (Class II Permissive Change)

FCC TEST REPORT North Mathilda Avenue, Sunnyvale, California Advance Data Technology Corporation

A Test Lab Techno Corp. FCC. RF Test Report. Product Type. : Mobile Hotspot. Applicant. : Netgear Inc.

EMC TEST REPORT. Product : Digital Camcorder Model No. : SCD5000. SAMSUNG ELECTRONICS Co., Ltd. EMC Test Laboratory. Project No.

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

Akkreditiertes Prüflaboratorium

Test Report. Applicant Address. : WALTOP International Corp. : 6F,No.19-1 Industry E.Rd.IV,Hsinchu Science Park,Hsin-Chu 30077,Taiwan,R.O.C.

TEST REPORT. iphone Hi-Fi Audio cable Adapter with Lightning female connector Model No.:

FCC DoC TEST REPORT APPLICANT: LSI CORP ADDRESS: 6145-D NORTHBELT PKY, NOR CROSS, GA 30071, USA

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

FCC PART 22H, PART 24E MEASUREMENT AND TEST REPORT. Shanghai AirM2M Communication Technology Co., Ltd

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

EMC REPORT. Shenzhen Sunchip Technology Co., Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of NYNE MULTIMEDIA INC. Bluetooth Speaker. Model Number: NYNE VIBE FCC ID: AWA-NYNEVIBE

STC (Dongguan) Company Limited EC VERIFICATION OF COMPLIANCE EMC-D163584VOC

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Akkreditiertes Prüflaboratorium

RF Test Report: Airspan ib440 to 47CFR SC_TR_150_B

Versatile EMS and EMI measurements for the automobile sector

LW10-T600. P10 Led Wall Display

Untertürkheimer Str. 6-10, Saarbruecken Phone: +49 (0) Fax: RSC-Laboratory Phone: +49 (0) Fax: -9075

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS-6967 FCC ID. : I4L-MS6967

FCC ID: IMK-ILCISA EMI TEST REPORT

FCC Part 15 Certification Test Report. 433 MHz Alarm System

R&S AMU-Z7 Analog I/Q Combiner Technical Information

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

EMC Test Report. Client: Crestron Electronics, Inc. Tested by: Jeremy O. Pickens, Senior EMC Engineer

JD725A Cable and Antenna Analyzer - Dual Port

R&S ZVA110 Vector Network Analyzer Specifications

Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. Bluetooth Speaker. Model Number: UB-SPB4M-101 FCC ID: ESXSPB4M

EMC Test Report. Client: Continental Automotive Systems, Inc. Tested by: Fendy Liauw, Engineering Technician

PDX75U36/6. 75" Professional Extra Bright Signage Displays. Key Features. Open Platform Support. OPS Support. Pixel Shifting.

REPORT Datum/Date Beteckning/Reference Sida/Page

R&S ZN-Z154 Calibration Unit Specifications

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. CD/USB RADIO. Model Number: TY-CWU700

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

R&S ZN-Z85 Switch Matrix Specifications

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

We, International Standards Laboratory, hereby certify that:

Class B digital device part 15 of the FCC rules

IH49V01D. 49" IPTV Hotel Series

IH43V01D. 43" IPTV Hotel Series

ANSI C63.4 and CISPR 22-Harmony

CERTIFICATION APPLICATION TEST REPORT

LAB CODE 571- Page No.: of 11 Measurement System Information General Information Testing Condition: Temperature: 5±3 C Humidity: <8% Measurement Facil

R&S RT-Zxx High-Bandwidth Probes Specifications

Transcription:

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-2 of TR-13 5 SUMMARY OF TEST RESULTS Emission testing No. Item Test procedure Page code Number of pages Test result 1. Conducted emission EN 55022: 2006 + A1:2007 EA 3 passed 2. Radiated emission <1GHz (others) EN 55022: 2006 + A1:2007 ER 3 passed 3. Radiated emission >1GHz EN 55022: 2006 + A1:2007 EG 4 passed total pages Emission 10 Immunity testing No. Item Test procedure Page code 1. Radiated susceptibility <1GHz Number of pages Test result EN 61000-4-3:1996 IR 2 passed total pages Immunity 2 total numbers of the first part of the test report (TR-) 13 total pages Emission 10 total pages Immunity 2 total number of pages of this test report 25 See section 7 for details of the test SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-3 of TR-13 6 CHARACTERISTICS, TEST CONFIGURATIONS AND OPERATION MODES OF THE EUT 6.1 General statements on the equipment under test item Technical documents EUT type Power supply Rated voltage Rated power consumption EN 61000-4-8 statement Were accompanied and made by the customer or by the manufacturer. It is a desktop equipment. It has a DC input. For the immunity tests a separate AC adapter (P2) was used and tested with it. DC 12-24 V 15 W The test was not performed because no devices susceptible to magnetic fields are existing. 6.2 components of EUT These components are part of the EUT component no. description of component serial no. / identification --- --- --- 6.3 peripheral equipment These equipment and appliances have been used for the tests: peripheral equipment no. (P..) description of equipment supplied by (see below) serial no. / identification P1 Netbook Asus Eee PC 1000HE C 930AAQ365792 P2 AC Adapter MeanWell GS25E12-P1 C R110224438 P3 USB-Stick 1GB Delock C -- P4 USB-Stick 1GB Delock C -- P5 Micro SD card 2GB Svandisk C -- P6 Peak CAN USB Adaptor IPEH-002022 C 39914 Codes for "supplied by": L = equipment supplied by the SHARP EMC Test Lab C = equipment supplied by the customer SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-4 of TR-13 6.4 connecting cables and terminals These cables have been used to connect the EUT with the peripheral equipment: cable no. (C..) description of cable terminal description length (cm) supplied by (see below) serial no. / identification C1 Ethernet Ethernet 200 C --- C2 RS232 / CAN RS232 / CAN 180 C --- C3 Extension CAN CAN 180 C --- C4 USB USB Host 300 C --- C5 USB USB OTG 300 C --- C6 USB Adapter Micro AB/A USB OTG 10 C --- C7 Audio Line-out 300 C --- C8 Speaker VECO 8Ohm 1W Speaker 50 C --- C9 Keypad (open lines) Keypad 30 C --- Codes for "supplied by": L = cable supplied by the SHARP EMC Test Lab C = cable supplied by the customer 6.5 configurations and operation modes The equipment under test (EUT) was tested in configurations and operation modes which are given here. The test records which have been produced during the tests mention the configuration and the operation modes with short codes used below; for example "A1" means that the EUT has been tested in configuration A with operation mode 1. 6.5.1 configurations code A description EUT with P1-P6 and C1- C9 The emission measurements were performed without AC adapter P2 6.5.2 operation modes code 1 Full Duplex 2 Half Duplex description SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-5 of TR-13 7 TESTS WHICH HAVE BEEN PERFORMED (TEST DESCRIPTIONS) The test data of the tests which have been performed belong to this test report as listed in section 5-SUMMARY OF TEST RESULTS. 7.1 conducted disturbances applied standard EN 55022 (class B) deviations from requirements given None in the a/m standard configurations and operation modes expanded measurement uncertainty of the test system test procedure code of page numbering in attached detailed test results A1 with ESH2-Z5 or ESH3-Z5: with ISN-T 800: with 9123-1N: with ESH2-Z3: ± 2,3 db ± 2,2 db ± 2,6 db ± 3,4 db At first a pre measurement with Peak- Detector were done to find out the frequencies with the highest value close to the limit; the measuring equipment are set to get maximum values in worst case. The test is passed in case the value is under the limit. Otherwise a final measurement with requested detector and settings according to the standards has to be performed at each critical value. EA See section 8 for details on the test instruments used. (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-6 of TR-13 7.2 interference radiation (30 MHz to 1 GHz) applied standard EN 55022 (class B) deviations from requirements given in the a/m standard None configurations and operation modes expanded measurement uncertainty of the test system test site A1 ± 4,4 db (10 m) ± 4,8 db (3 m) semi anechoic chamber measuring distance 10 m (EN 55022) 3 m (EN 55013) test procedure code of page numbering in attached detailed test results At first a pre measurement with Peak- Detector were done to find out the frequencies with the highest value close to the limit; the measuring equipment are set to get maximum values in worst case. The test is passed in case the value is under the limit with enough margin. Otherwise a final measurement with requested detector and settings according to the standards has to be performed at each critical value. During the pre and final measurements the measuring antenna height was varied and EUT was turned a full rotation. ER See section 8 for details on the test instruments used. (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-7 of TR-13 (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-8 of TR-13 7.3 interference radiation (1 GHz to 6 GHz) applied standard EN 55022 (class B) deviations from requirements given in the a/m standard None configurations and operation modes expanded measurement uncertainty of the test system test site measuring distance antenna height minimum dimension of w (antenna) test procedure code of page numbering in attached detailed test results A1 ± 4,0 db semi anechoic chamber 3 m 130 cm 1 GHz: 2,8 m; 3 GHz: 2,3 m; 4 GHz and 6 GHz: 2,01 m During the Peak and AV measurements the EUT was turned a full rotation in order to obtain the maximum value of the electromagnetic field strength. EG See section 8 for details on the test instruments used. (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-9 of TR-13 (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-10 of TR-13 7.4 immunity against radiated fields (< 1 GHz) applied standard EN 61000-4-3, as specified in EN 55024 deviations from requirements given in the a/m standard expanded measurement uncertainty of the test system configurations and operation modes performance criterion code of page numbering in attached detailed test results Because of the small EUT size the test was performed from two sides only. According to customer request the performed test level was increased. ± 4,4 db A1, A2 criterion A See section 8 for details on the test instruments used. IR (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-11 of TR-13 (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-12 of TR-13 8 TEST INSTRUMENTS All instruments have been calibrated and maintained within their calibration period as defined in the Quality Management System of the SHARP EMC Testing Laboratory. EMC test instrument relevant for test result instrument model name and serial number conducted disturbances EMC test receiver Rohde & Schwarz ESCI Ser. No.: 100366 conducted disturbances conducted disturbances Artificial Mains Network (3-phase) Impedance stabilization network ESH 2-Z5 Ser. No.: 893606/017 ISN T800 Ser. No. 26100 conducted disturbances current probe 9123-1N Ser. No. 993517 interference radiation EMC test receiver Rohde & Schwarz ESVS10 Ser. No.: 839049/009 interference radiation interference radiation interference radiation immunity against radiated fields; < 1 GHz immunity against radiated fields; < 1 GHz immunity against radiated fields Spectrum analyzer BiLog antenna 30 1000 MHz Horn antenna 1 18 GHz Power meter Power head Rohde & Schwarz FSP30 Ser. No.: 100461 Schwarzbeck VULB 9168 Ser. No. 344 EMCO 3115 Ser. No. 8908-3268 Rohde & Schwarz NAP Ser No. 833342/014 Rohde & Schwarz NAP-Z6 Ser. No. 838225/030 Field probe Narda EMR 300 with probe type 8.3 Ser. No. AY-0100 / BB-0002 test lab instrument list number 0219 0016 0223 0146 0210 0209 0226 0007 0097 0098 0211 SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026

SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-13 of TR-13 CONTENTS 1 TESTED EQUIPMENT (Equipment under Test [EUT]) 1 2 TEST RESULTS 1 3 STATEMENT 1 4 SIGNATURES AND STAMP 1 5 SUMMARY OF TEST RESULTS 2 6 CHARACTERISTICS, TEST CONFIGURATIONS AND OPERATION MODES OF THE EUT 3 6.1 General statements on the equipment under test 3 6.2 components of EUT 3 6.3 peripheral equipment 3 6.4 connecting cables and terminals 4 6.5 configurations and operation modes 4 6.5.1 configurations 4 6.5.2 operation modes 4 7 TESTS WHICH HAVE BEEN PERFORMED (TEST DESCRIPTIONS) 5 7.1 conducted disturbances 5 7.2 interference radiation (30 MHz to 1 GHz) 6 7.3 interference radiation (1 GHz to 6 GHz) 8 7.4 immunity against radiated fields (< 1 GHz) 10 8 TEST INSTRUMENTS 12 page SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026