SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-2 of TR-13 5 SUMMARY OF TEST RESULTS Emission testing No. Item Test procedure Page code Number of pages Test result 1. Conducted emission EN 55022: 2006 + A1:2007 EA 3 passed 2. Radiated emission <1GHz (others) EN 55022: 2006 + A1:2007 ER 3 passed 3. Radiated emission >1GHz EN 55022: 2006 + A1:2007 EG 4 passed total pages Emission 10 Immunity testing No. Item Test procedure Page code 1. Radiated susceptibility <1GHz Number of pages Test result EN 61000-4-3:1996 IR 2 passed total pages Immunity 2 total numbers of the first part of the test report (TR-) 13 total pages Emission 10 total pages Immunity 2 total number of pages of this test report 25 See section 7 for details of the test SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-3 of TR-13 6 CHARACTERISTICS, TEST CONFIGURATIONS AND OPERATION MODES OF THE EUT 6.1 General statements on the equipment under test item Technical documents EUT type Power supply Rated voltage Rated power consumption EN 61000-4-8 statement Were accompanied and made by the customer or by the manufacturer. It is a desktop equipment. It has a DC input. For the immunity tests a separate AC adapter (P2) was used and tested with it. DC 12-24 V 15 W The test was not performed because no devices susceptible to magnetic fields are existing. 6.2 components of EUT These components are part of the EUT component no. description of component serial no. / identification --- --- --- 6.3 peripheral equipment These equipment and appliances have been used for the tests: peripheral equipment no. (P..) description of equipment supplied by (see below) serial no. / identification P1 Netbook Asus Eee PC 1000HE C 930AAQ365792 P2 AC Adapter MeanWell GS25E12-P1 C R110224438 P3 USB-Stick 1GB Delock C -- P4 USB-Stick 1GB Delock C -- P5 Micro SD card 2GB Svandisk C -- P6 Peak CAN USB Adaptor IPEH-002022 C 39914 Codes for "supplied by": L = equipment supplied by the SHARP EMC Test Lab C = equipment supplied by the customer SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-4 of TR-13 6.4 connecting cables and terminals These cables have been used to connect the EUT with the peripheral equipment: cable no. (C..) description of cable terminal description length (cm) supplied by (see below) serial no. / identification C1 Ethernet Ethernet 200 C --- C2 RS232 / CAN RS232 / CAN 180 C --- C3 Extension CAN CAN 180 C --- C4 USB USB Host 300 C --- C5 USB USB OTG 300 C --- C6 USB Adapter Micro AB/A USB OTG 10 C --- C7 Audio Line-out 300 C --- C8 Speaker VECO 8Ohm 1W Speaker 50 C --- C9 Keypad (open lines) Keypad 30 C --- Codes for "supplied by": L = cable supplied by the SHARP EMC Test Lab C = cable supplied by the customer 6.5 configurations and operation modes The equipment under test (EUT) was tested in configurations and operation modes which are given here. The test records which have been produced during the tests mention the configuration and the operation modes with short codes used below; for example "A1" means that the EUT has been tested in configuration A with operation mode 1. 6.5.1 configurations code A description EUT with P1-P6 and C1- C9 The emission measurements were performed without AC adapter P2 6.5.2 operation modes code 1 Full Duplex 2 Half Duplex description SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-5 of TR-13 7 TESTS WHICH HAVE BEEN PERFORMED (TEST DESCRIPTIONS) The test data of the tests which have been performed belong to this test report as listed in section 5-SUMMARY OF TEST RESULTS. 7.1 conducted disturbances applied standard EN 55022 (class B) deviations from requirements given None in the a/m standard configurations and operation modes expanded measurement uncertainty of the test system test procedure code of page numbering in attached detailed test results A1 with ESH2-Z5 or ESH3-Z5: with ISN-T 800: with 9123-1N: with ESH2-Z3: ± 2,3 db ± 2,2 db ± 2,6 db ± 3,4 db At first a pre measurement with Peak- Detector were done to find out the frequencies with the highest value close to the limit; the measuring equipment are set to get maximum values in worst case. The test is passed in case the value is under the limit. Otherwise a final measurement with requested detector and settings according to the standards has to be performed at each critical value. EA See section 8 for details on the test instruments used. (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-6 of TR-13 7.2 interference radiation (30 MHz to 1 GHz) applied standard EN 55022 (class B) deviations from requirements given in the a/m standard None configurations and operation modes expanded measurement uncertainty of the test system test site A1 ± 4,4 db (10 m) ± 4,8 db (3 m) semi anechoic chamber measuring distance 10 m (EN 55022) 3 m (EN 55013) test procedure code of page numbering in attached detailed test results At first a pre measurement with Peak- Detector were done to find out the frequencies with the highest value close to the limit; the measuring equipment are set to get maximum values in worst case. The test is passed in case the value is under the limit with enough margin. Otherwise a final measurement with requested detector and settings according to the standards has to be performed at each critical value. During the pre and final measurements the measuring antenna height was varied and EUT was turned a full rotation. ER See section 8 for details on the test instruments used. (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-7 of TR-13 (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-8 of TR-13 7.3 interference radiation (1 GHz to 6 GHz) applied standard EN 55022 (class B) deviations from requirements given in the a/m standard None configurations and operation modes expanded measurement uncertainty of the test system test site measuring distance antenna height minimum dimension of w (antenna) test procedure code of page numbering in attached detailed test results A1 ± 4,0 db semi anechoic chamber 3 m 130 cm 1 GHz: 2,8 m; 3 GHz: 2,3 m; 4 GHz and 6 GHz: 2,01 m During the Peak and AV measurements the EUT was turned a full rotation in order to obtain the maximum value of the electromagnetic field strength. EG See section 8 for details on the test instruments used. (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-9 of TR-13 (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-10 of TR-13 7.4 immunity against radiated fields (< 1 GHz) applied standard EN 61000-4-3, as specified in EN 55024 deviations from requirements given in the a/m standard expanded measurement uncertainty of the test system configurations and operation modes performance criterion code of page numbering in attached detailed test results Because of the small EUT size the test was performed from two sides only. According to customer request the performed test level was increased. ± 4,4 db A1, A2 criterion A See section 8 for details on the test instruments used. IR (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-11 of TR-13 (photograph of test setup) SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-12 of TR-13 8 TEST INSTRUMENTS All instruments have been calibrated and maintained within their calibration period as defined in the Quality Management System of the SHARP EMC Testing Laboratory. EMC test instrument relevant for test result instrument model name and serial number conducted disturbances EMC test receiver Rohde & Schwarz ESCI Ser. No.: 100366 conducted disturbances conducted disturbances Artificial Mains Network (3-phase) Impedance stabilization network ESH 2-Z5 Ser. No.: 893606/017 ISN T800 Ser. No. 26100 conducted disturbances current probe 9123-1N Ser. No. 993517 interference radiation EMC test receiver Rohde & Schwarz ESVS10 Ser. No.: 839049/009 interference radiation interference radiation interference radiation immunity against radiated fields; < 1 GHz immunity against radiated fields; < 1 GHz immunity against radiated fields Spectrum analyzer BiLog antenna 30 1000 MHz Horn antenna 1 18 GHz Power meter Power head Rohde & Schwarz FSP30 Ser. No.: 100461 Schwarzbeck VULB 9168 Ser. No. 344 EMCO 3115 Ser. No. 8908-3268 Rohde & Schwarz NAP Ser No. 833342/014 Rohde & Schwarz NAP-Z6 Ser. No. 838225/030 Field probe Narda EMR 300 with probe type 8.3 Ser. No. AY-0100 / BB-0002 test lab instrument list number 0219 0016 0223 0146 0210 0209 0226 0007 0097 0098 0211 SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026
SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-13 of TR-13 CONTENTS 1 TESTED EQUIPMENT (Equipment under Test [EUT]) 1 2 TEST RESULTS 1 3 STATEMENT 1 4 SIGNATURES AND STAMP 1 5 SUMMARY OF TEST RESULTS 2 6 CHARACTERISTICS, TEST CONFIGURATIONS AND OPERATION MODES OF THE EUT 3 6.1 General statements on the equipment under test 3 6.2 components of EUT 3 6.3 peripheral equipment 3 6.4 connecting cables and terminals 4 6.5 configurations and operation modes 4 6.5.1 configurations 4 6.5.2 operation modes 4 7 TESTS WHICH HAVE BEEN PERFORMED (TEST DESCRIPTIONS) 5 7.1 conducted disturbances 5 7.2 interference radiation (30 MHz to 1 GHz) 6 7.3 interference radiation (1 GHz to 6 GHz) 8 7.4 immunity against radiated fields (< 1 GHz) 10 8 TEST INSTRUMENTS 12 page SHARP Shared Services Europe, Sonninstr. 3, D-20097 Hamburg, Germany; filename: NESOLT43OFRS485-REPORT-11-250-02.DOCForm No.: 051-040 A - Version 026