Our cables at: ENGLISH CHANNEL TALLIN PORT MECCA METRO PULKOVO AIRPORT

Similar documents
CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

Instrumentation Cables

Detailed Specifications & Technical Data

17 Bulk Cables INSTRUMENT CABLES SS/ONE CS/535 CS/ SS/ONE SONIC SOLUTIONS HIGH DEFINITION INSTRUMENT CABLE MADE IN ITALY

Compact Module. Category 6 FTP Cabling System

Cables for robot applications

Bus Cables & Industrial Ethernet Cables

PRODUCTS COMPANY SERVICES

Continuous Flex Data Cable

BUS UNITRONIC BUS CAN

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

Instrumentation & copper telecom cables

SHIELDED DIGITAL CABLES (1249C SERIES)

Photo: HELUKABEL â. Special cables

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

STRUCTURED CABLING SYSTEMS (SCS)

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

GenSPEED Category 5e Cables 3

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

Detailed Specifications & Technical Data

PREMIUM 5e F/UTP PRODUCTS

CATEGORY 5e CABLING SOLUTIONS

HARTING Ethernet cabling cables and connectors, 4 wire

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Category 5e F/UTP Euroclass D ca Cables

Detailed Specifications & Technical Data

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

Volition TM Category 5e cable 100 Ω, FTP

Detailed Specifications & Technical Data

CATEGORY 6 CABLING SOLUTIONS

Siam Pacific Electric Wire & Cable Co., Ltd.

Magic Patch Patch Leads & Accessories

BTNS TM. FTP Compact Module

Bravo AV s Structured or Whole-House Wiring Approach

Content BULK CABLES VIDEO CABLES AUDIO CABLES EXTENDERS USB CABLES ETHERNET CABLES VIDEO BALUNS CONNECTORS ADAPTERS PATCH PANELS & WALLPLATES TOOLS

CAT5E NETWORK PATCH LEADS

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59

Detailed Specifications & Technical Data

Welcome to the latest edition of the Telstra Cable Guide.

PATCH CORDS, PLUGS & CABLES

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

Part Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable

Gear up for the future.

Jacket: Premium PVC compound Packaging: Please contact Customer Service for packaging and color options. 100% Flexfoil 30 Ga. CCS

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

ENGINEERING COMMITTEE Interface Practices Subcommittee. ANSI/SCTE (Formerly IPS SP 001)

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

Kwangil Electronic Introduction

QED PROFESSIONAL INSTALLATION CABLES

Low Voltage Wires and Cables: New Applications for Thermoplastics

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

Multi-Media Installation Guide

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

CATALOGUE PRODUCT CATALOGUE CCS CONNECTIVITY & CABLING SYSTEM STRUCTURED CABLING SYSTEM. is a trademark of:

Connectivity for Ethernet

Combining Value and Performance Like No One Else

Table of Contents. Open Matrix System (OMS) 1-2

RG-59/RG-6/RG-11 LSZH SERIES MAIN FEATURES

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

CONTRACTORS SPECIFICATION

Detailed Specifications & Technical Data

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

CABLE SIZE AND INSTALLATION GUIDE

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

RZ1-K BS EN XLPE LSZH Flexible Cable

YEAR END STOCK CLEARANCE

Effective earthing of screened cables

11-piece Electronic Tool Kit in Wallet. From only. Rapid Lead-Free Solder Wire 22SWG 0.7mm 100g Reel. From only 4.29

Road cables. The foundation for a reliable traffic infrastructure.

Flygt Submersible Motor Cables

Model FS-4608R. Features. Overview

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

btnet new products Modular and preloaded patch panels btnet

ICON Instrumentation Cables

ULTIMATE SNAP-N-SEAL

1672A. Product Description. Product Specifications. Technical Specifications. Conductor. APAC Standard. Bend Radius.

TABLE Of CONTENTS JACKET COLOR OPTIONS TABLE OF CONTENTS COMPANY INFORMATION CATEGORY 5E CABLES CATEGORY 6 CABLES CATEGORY 6A CABLES

Telemetry Receiver Installation Guide

HIGH QUALITY RG-11 CCS SERIES CABLES FOR SATELLITE, CABLE TV ANTENNA RECEPTION AND DISTRIBUTION. Main Features

PRODUCT INFORMATION. ETHERLINE EC Flex Cat.5e M8

DINTEK LAN Cabling Systems

The Communication Cable Specialists. Qing CABLES. Qing Cables Qing Cables. Qing Cables

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

Caledonian Instrumentation Cables

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

Model FS HD4301VPD. Features

How Wire Fails Originally presented to the Society of Motion Picture and Television Engineers Convention, Sydney, Australia, on Friday, July 4, 1997.

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

Model. Features FS-HD4301VPC

CABLES AND WIRES

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009

Transcription:

Our cables at: ENGLISH CHANNEL TALLIN PORT MECCA METRO PULKOVO AIRPORT

RAMCRO with his presence in Europe, Middle East, India and Latin America is a cable manufacture know in the world, now operates across more market sectors and countries than ever before, delivering innovative value added services, an extensive range of cable products and cost effective supply chain solutions. Buildings & Industrial, Utilities, Railways and Telecommunications are their active market sectors with an extensive array of products specifically designed and produced to satisfy the demanding needs of their Global marketplace. RAMCRO facility and cable products are of the highest quality, with Italian design end manifacture, that indicate to the market that RAMCRO is your best solution for delivery and affidability. - Instrumentation & Control -Multi Pair Coaxial -Voice and Data 3 Visit RAMCRO at or contact our office (see back page for details). This brochure represents only a small selection of the products RAMCRO can supply. CONTENTS CABLE FINDER SECTION 1 - PAIRED CABLES SECTION 2 - MULTI-CONDUCTOR CABLES SECTION 3 - FIRE DETECTION AND ALARM SYSTEM CABLES SECTION 4 - FIRE RESISTANT CABLES SECTION 5 - COAX CABLES SECTION 6 - CATEGORY LAN CABLES SECTION 7 - DEF. STAN. CABLES SECTION 8 - INSTRUMENTATION CABLES SECTION 9 - CONTROL CABLES GENERAL TECHNICAL INFORMATION COMPARISON BETWEEN EUROPEAN & UNITED STATES CABLE DESIGN BASICS CONVERSIONS GLOSSARY PART NUMBER IDENTIFICATION CHART

Cable Finder CABLE FINDER Paired cables RS-485 Cond. - Size 24 AWG Screen No. of Pairs Sheath 1 2 3 4 PVC MAR0108HBADX-T C1189 MAR0208HBADX-T C1190 MAR0308HBADX-T C1191 MAR0408HBADX-T C1192 Foil + 24 AWG HFFR MAR0108HXEDX-T C1318 MAR0208HXEDX-T C1319 MAR0308HXEDX-T C1320 MAR0408HXEDX-T C1321 Braid 22 AWG PVC MAR0107HBADX-T C1080 MAR0207HBADX-T C1295 MAR0307HBADX-T C1296 MAR0407HBADX-T C1297 Application RS-422 24 AWG Each PVC - - MAP0208HBADX-T C1382 MAP0308HBADX-T C1383 MAP0408HBADX-T C1384 22 AWG Pair foil screened PVC - - MAP0207HBADX-T C1196 MAP0307HBADX-T C1197 - - G.P. Bus 22 AWG HFFR - - MAP0207HBEDX-T C1281 MAP0307HBEDX-T C1282 - - 18 AWG Foil HFFR MAS0105HBEDX-T C1171 MAS0205HBEDX-T C1172 MAS0305HBEDX-T C1173 MAS0405HBEDX-T C1174 RS-232 24 AWG Foil PVC MAS0108HBAAH-T C1181 MAS0208HBAAH-T C1182 MAS0308HBAAH-T C1183 MAS0408HBAAH-T C1184 Lon Works KNX 0.64 mm No Scrn HFFR MSE0107HXEDX C1346 MSE0207HXEDX C1347 - - - - 0.64 mm Each Pair Foil Screened HFFR MAS0107HXEDX C1348 MAC0207HXEDX C1349 - - - - 0.8 mm PVC MAS0108HIADH C1219 MAS0208HIADH C1217 - - - - Foil 0.8 mm HFFR MAS0108HIEDH C1220 MAS0208HIEDH C1218 - - - - 4 Application G.P. Bus No.of Pairs Screen No. of Pairs Sheath AWG 22 AWG 20 AWG 18 Section 1 Yes PVC MAS0107HBADN-T C1199 MAS0106HBADN-T C1195 MAS0105HBADN-T C1193 1.7 18 1 Yes HFFR MAS0107HXEDN-T C1310 MAS0106HXEDN-T C1308 MAS0105HXEDN-T C1272 1.7 18 1 No PVC MSE0107HBADN-T C1301 MSE0106HBADN-T C1300 MSE0105HBADN-T C1203 1.7 18 1 No HFFR MSE0107HXEDN-T C1311 MSE0106HXEDN-T C1309 MSE0105HXEDN-T C1271 1.7 18 Page Multi-conductor cables Cond. Size AWG No. of Cores Sheath Screen 2 3 4 6 22 PVC HFFR Yes SAS0207HBAXH C1226 SAS0307HBAXX C1228 SAS0407HBAXX C1230 SAS0637HBAXX C1264 No SSS0207HBAXH C1227 SSS0307HBAXX C1278 SSS0407HBAXX C1231 SSS0607HBAXX C1265 Yes SAS0207HXEDH C1741 SAS0307HXEDX C1743 SAS0407HXEDX C1745 SAS0607HXEDX C1747 No SSS0207HXEDH C1742 SSS0307HXEDX C1744 SSS0407HXEDX C1746 SSS0607HXEDX C1748 20 PVC HFFR Yes SAS0206HBAXH C1019 SAS0306HBAXX C1021 SAS0406HBAXX C1023 SAS0606HBAXX C1260 No SSS0206HBAXH C1020 SSS0306HBAXX C1022 SSS0406HBAXX C1024 SSS0606HBAXX C1261 Yes SAS0206HXEDH C1731 SAS0306HXEDX C1733 SAS0406HXEDX C1735 SAS0606HXEDX C1737 No SSS0206HXEDH C1732 SSS0306HXEDX C1734 SSS0406HXEDX C1736 SSS0606HXEDX C1738 18 PVC HFFR Yes SAS0205HBAXH C1013 SAS0305HBAXX C1015 SAS0405HBAXX C1017 SAS0605HBAXX C1211 No SSS0205HBAXH C1014 SSS0305HBAXX C1016 SSS0405HBAXX C1018 SSS0605HBAXX C1212 Yes SAS0205HXEDH C1721 SAS0305HXEDX C1723 SAS0405HXEDX C1725 SAS0605HXEDX C1727 No SSS0205HXEDH C1722 SSS0305HXEDX C1724 SSS0305HXEDX C1726 SSS0605HXEDX C1728 UV-HFFR Yes SAS0205HBOXH C1351 SAS0305HBOXX C1352 SAS0405HBOXX C1353 SAS0605HBOXX C1354 16 PVC HFFR Yes SAS0203HBAXH C1007 SAS0303HBAXX C1009 SAS0403HBAXX C1011 SAS0603HBAXX C1252 No SSS0203HBAXH C1008 SSS0303HBAXX C1010 SSS0403HBAXX C1012 SSS0603HBAXX C1253 Yes SAS0203HXEDH C1711 SAS0303HXEDX C1713 SAS0403HXEDX C1715 SAS0603HXEDX C1717 No SSS0203HXEDH C1712 SSS0303HXEDX C1714 SSS0403HXEDX C1716 SSS0603HXEDX C1718 UV-HFFR Yes SAS0203HBOXH C1391 SAS0303HBOXX C1392 SAS0403HBOXX C1393 SAS0603HBOXX C1394 14 12 PVC HFFR PVC HFFR Yes SAS0201HBAXH C1001 SAS0301HBAXX C1003 SAS0401HBAXX C1005 SAS0601HBAXX C1248 No SSS0201HBAXH C1002 SSS0301HBAXX C1004 SSS0401HBAXX C1006 SSS0601HBAXX C1249 Yes SAS0201HXEDH C1701 SAS0301HXEDX C1703 SAS0401HXEDX C1705 SAS0601HXEDX C1707 No SSS0201HXEDH C1702 SSS0301HXEDX C1704 SSS0401HXEDX C1706 SSS0601HXEDX C1708 Yes SAS0252HBAXH C1322 SAS0352HBAXX C1324 SAS0452HBAXX C1326 SAS0652HBAXX C1330 No SSS0252HBAXH C1323 SSS0352HBAXX C1325 SSS0452HBAXX C1327 SSS0652HBAXX C1331 Yes SAS0252HXEDH C1334 SAS0352HXEDX C1336 SAS0452HXEDX C1338 SAS0652HXEDX C1342 No SSS0252HXEDH C1335 SSS0352HXEDX C1337 SSS0452HXEDX C1339 SSS0652HXEDX C1343 Multi- Power Limited Tray Cables (PLTC) are available on request

Cable Finder Cond. - Size 24 AWG Screen No. of Pairs Sheath 5 6 7 8 PVC - - - - - - - - 1.1 12 Foil + 24 AWG HFFR - - - - - - - - 1.1 12 Braid 22 AWG PVC - - - - - - - - 1.1 12 24 AWG PVC - - MAP0608HBADX-T C1386 - - - - 1.2 13 22 AWG Each Pair foil PVC - - MAP0607HBADX-T C1214 - - - - 1.6 17 screened 22 AWG HFFR - - MAP0607HBEDX-T C1314 - - - - 1.6 17 18 AWG Foil HFFR MAS0505HBEDX-T C1175 MAS0605HBEDX-T C1176 - - - - 1.8 19 SEC- TION PAGE CABLE FINDER 24 AWG Foil PVC MAS0508HBAAH-T C1185 MAS0608HBAAH-T C1186 MAS0708HBAAH-T C1187 MAS0808HBAAH-T C1188 1.3 14 0.64 mm No Scrn HFFR - - - - - - - - 1.5 16 0.64 mm Each Pair Foil Screened HFFR - - - - - - - - 1.5 16 0.8 mm PVC - - - - - - - - 1.4 15 Foil 0.8 mm HFFR - - - - - - - - 1.4 15 Application G.P. Bus No.of Pairs Screen No. of Pairs Sheath AWG 16 AWG 14 AWG 12 Section 1 Yes PVC MAS0103HBADN-T C1213 MAS0101HBADN-T C1224 MAS0152HBADN-T C1313 1.7 18 1 Yes HFFR MAS0103HXEDN-T C1270 MAS0101HXEDN-T C1305 MAS0152HXEDN-T C1303 1.7 18 1 No PVC MSE0103HBADN-T C1198 MSE0101HBADN-T C1222 MSE0152HBADN-T C1302 1.7 18 1 No HFFR MSE0103HXEDN-T C1307 MSE0101HXEDN-T C1306 MSE0152HXEDN-T C1304 1.7 18 Page 5 8 Section Page SAS0837HBAXX C1232 2.1 21 SSS0807HBAXX C1233 2.1 21 SAS0807HXEDX C1749 2.2 22 SSS0807HXEDX C1750 2.2 22 SAS0806HBAXX C1262 2.1 21 SSS0806HBAXX C1263 2.1 21 SAS0806HXEDX C1739 2.2 22 SSS0806HXEDX C1740 2.2 22 SAS0805HBAXX C1258 2.1 21 SSS0805HBAXX C1259 2.1 21 SAS0805HXEDX C1729 2.2 22 SSS0805HXEDX C1730 2.2 22 SAS0805HBOXX C1355 2.3 23 SAS0803HBAXX C1254 2.1 21 SSS0803HBAXX C1255 2.1 21 SAS0803HXEDX C1719 2.2 22 SSS0803HXEDX C1720 2.2 22 SAS0803HBOXX C1395 2.3 23 SAS0801HBAXX C1250 2.1 21 SSS0801HBAXX C1251 2.1 21 SAS0801HXEDX C1709 2.2 22 SSS0801HXEDX C1710 2.2 22 SAS0852HBAXX C1332 2.1 21 SSS0852HBAXX C1333 2.1 21 SAS0852HXEDX C1344 2.2 22 SSS0852HXEDX C1345 2.2 22

Cable Finder CABLE FINDER Fire detection and alarm system cables Fire Alarm No. of pairs Cond. size Screen Sheath AWG 18 AWG 16 AWG 14 AWG 12 1 Yes PVC SAR0203HFCCH C1040 SAR0202HFCCH C1041 SAR0201HFCCH C1042 SAR0252HFCCH C1043 3 24 1 No PVC SSR0203HFCCH C1135 SSR0202HFCCH C1136 SSR0201HFCCH C1137 SSR0252HFCCH C1138 3 24 Fire Resistant cables No. of Cores Cond. size Screen Sheath 0.75 mm 2 1.0 mm 2 1.5 mm 2 2.5 mm 2 4.0 mm 2 Section Page Application Application Section Page 2 Yes HFFR SAR0210HFESL-F3 C1284 SAR0211HFESL-F3 C1283 SAR0214HFESL-F3 C1044 SAR0218HFESL-F3 C1045 SAS0240HFESL-F3 C1289 4 26 Circuit integrities 2 No HFFR SSR0210HFESL-F3 C1139 SSR0211HFESL-F3 C1140 SSR0214HFESL-F3 C1141 SSR0218HFESL-F3 C1142 SSS0240HFESL-F3 C1143 4 26 3 Yes HFFR SAR0310HFESL-F3 C1159 SAR0311HFESL-F3 C1160 SAR0314HFESL-F3 C1161 SAR0318HFESL-F3 C1162 SAS0340HFESL-F3 C1163 4 26 3 No HFFR SSR0310HFESL-F3 C1149 SSR0311HFESL-F3 C1150 SSR0314HFESL-F3 C1151 SSR0318HFESL-F3 C1152 SSS0340HFESL-F3 C1153 4 26 Coax cables 6 Application CCTV SMATV CATV HDTV Inner Screen Sheath RG-59 RG-6 RG-11 Solid BC Braid BC PVC RG59 C1028 RG6 C1029 RG11 C1030 5.1 28 Solid BC Braid BC HFFR RG59-ZA C1428 RG6-ZA C1429 RG11-ZA C1430 5.1 28 Flex BC Braid BC PVC RG59-FLEX C1275 RG6-FLEX C1276 RG11-FLEX C1277 5.1 28 CCS Foil + Alu Braid PVC RG59-FA C1025 RG6-FA C1026 RG11-FA C1027 5.2 29 CCS Quad Screen PVC RG59-QS C1256 RG6-QS C1257 RG11-QS C1241 5.2 29 Solid BC Foil + TC Braid PVC RG59-FTC C1229 RG6-FTC C1279 RG11-FTC C1280 5.3 30 Solid BC Foil + TC Braid HFFR RG59-ZA-FTC C1378 RG6-ZA-FTC C1379 RG11-ZA-FTC C1380 5.3 30 Section Page 50 Ohm Coaxial cables are available on request Category LAN cables Cat. types Sheath UTP FTP U-UTP U-FTP S-FTP Section Page Cat 5e Cat 6 Cat 6a PVC UTPLevel5-4x2x0.22 C1035 FTPLevel54x2x0.22 C1036 - - - - - - 6.1 33 HFFR UTPLevel5-4x2x0.22ZA C1235 FTPLevel54x2x0.22ZA C1236 - - - - - - 6.1 33 PVC UTPLevel6-4x2x0.22 C1037 FTPLevel64x2x0.22 C1038 - - - - - - 6.1 33 HFFR UTPLevel6-4x2x0.22ZA C1237 FTPLevel64x2x0.22ZA C1238 - - - - - - 6.1 33 PVC - - - - - - - - - - 6.2 34 HFFR - - - - UUTPLevel6-4x2x0.22 C1200 UFTPLevel6-4x2x0.22 C1053-6.2 34 Cat 7 HFFR - - - - - - - - SFTPLevel7 C1039 6.2 34 Cat 7a HFFR - - - - - - - - SFTPLevel7-ZA C1201 6.2 34 Cat 5e - patch Cat 6 - patch PVC UTPLevel5-4x2x0.22-Patch C1500 FTPLevel54x2x0.22-Patch C1520 - - - - - - 6.3 35 HFFR UTPLevel5-4x2x0.22ZA-Patch C1510 FTPLevel54x2x0.22ZA-Patch C1530 - - - - - - 6.4 35 PVC UTPLevel6-4x2x0.22-Patch C1540 FTPLevel64x2x0.22-Patch C1560 - - - - - - 6.4 35 HFFR UTPLevel6-4x2x0.22ZA-Patch C1550 FTPLevel64x2x0.22ZA-Patch C1570 - - - - - - 6.4 35 Category 3 LAN cables Cat. types Sheath 2 pairs 6 pairs 12 pairs 25 pairs Section Page Cat 3 PVC Cat3-2P C1031 Cat3-6P C1266 Cat3-12P C1267 Cat3-25P C1032 6.4 36 Cat. types Sheath 50 pairs 100 pairs 150 pairs 200 pairs Section Page Cat 3 PVC Cat3-50P C1033 Cat3-100P C1034 Cat3-150P C1268 Cat3-200P C1269 6.4 36

Cable Finder DEF. Stan. cables 7 x 0.1 mm = 0.055 mm 2 No. of Cores 2-3 - 4-6 - 9 - Section Page Screened STS0201HEAAX-T C1164 STS0301HEAAX-T C1165 - STS0601HEAAX-T C1166 - - 7 38 Unscreened SSS0201HEAAX-T C1360 SSS0301HEAAX-T C1361 SSS0401HEAAX-T C1362 SSS0601HEAAX-T C1144 SSS0901HEAAX-T C1145 7 38 7 x 0.1 mm = 0.055 mm 2 CABLE FINDER No. of Cores 15-25 - 36-50 - Section Page Screened - - STS2501HEAAX-T C1168 STS3601HEAAX-T C1169 STS5001HEAAX-T C1365 7 38 Unscreened SSS1501HEAAX-T C1146 SSS2501HEAAX-T C1147 SSS3601HEAAX-T C1148 SSS5001HEAAX-T C1364 7 38 7 x 0.2 mm = 0.22 mm 2 No. of Cores 2-3 - 4-6 - Section Page 7 Screened - - - - STS0422HEAAX-T C1471 STS0622HEAAX-T C1472 7 38 Unscreened SSS0222HEAAX-T C1366 SSS0322HEAAX-T C1367 SSS0422HEAAX-T C1368 SSS0622HEAAX-T C1369 7 38 7 x 0.2 mm = 0.22 mm 2 No. of Cores 8-12 - 20-36 - Section Page Screened STS0822HEAAX-T C1473 STS1222HEAAX-T C1474 STS2022HEAAX-T C1475 STS3622HEAAX-T C1476 7 38 Unscreened SSS0822HEAAX-T C1154 SSS1222HEAAX-T C1155 SSS2022HEAAX-T C1156 SSS3622HEAAX-T C1157 7 38 16 x 0.2 mm = 0.5 mm 2 No. of Cores 2-3 - 4 - Section Page Screened - - - - STS0450HEAAX-T C1177 7 38 Unscreened SSS0250HEAAX-T C1158 SSS0350HEAAX-T C1370 SSS0450HEAAX-T C1371 7 38 16 x 0.2 mm = 0.5 mm 2 No. of Cores 6-12 - 18 - Section Page Screened STS0650HEAAX-T C1178 STS1250HEAAX-T C1375 STS1850HEAAX-T C1180 7 38 Unscreened SSS0650HEAAX-T C1372 SSS1250HEAAX-T C1373 SSS1850HEAAX-T C1374 7 38

Cable Finder CABLE FINDER Instrumentation cables BS5308/PAS5308-2 - Type 1 & 2 - Collectively Screened - Unarmoured cables No. of Pairs 1-2 - 5-10 - 20 - Section Page 0.5 mm 2 (16x0.2 mm) MAS0150HEAAX-OIL C1081 MAS0250HEAAX-OIL C1082 MAS0550HEAAX-OIL C1083 MAS1050HEAAX-OIL C1084 MAS2050HEAAX-OIL C1085 8 40 0.75 mm 2 (24x0.2 mm) MAS0175HEAAX-OIL C1086 MAS0275HEAAX-OIL C1087 MAS0575HEAAX-OIL C1088 MAS1075HEAAX-OIL C1089 MAS2075HEAAX-OIL C1090 8 40 1.5 mm 2 (7x0.53 mm) MAS0115HEAAX-OIL C1091 MAS0215HEAAX-OIL C1092 MAS0515HEAAX-OIL C1093 MAS1015HEAAX-OIL C1094 MAS2015HEAAX-OIL C1095 8 40 BS5308/PAS5308-2 -Type 1 & 2 - Collectively Screened - Armoured cables No. of Pairs 1-2 - 5-10 - 20 - Section Page 0.5 mm 2 (16x0.2 mm) MAS0150AEAAX-OIL C1096 MAS0250AEAAX-OIL C1097 MAS0550AEAAX-OIL C1098 MAS1050AEAAX-OIL C1099 MAS2050AEAAX-OIL C1100 8 40 0.75 mm 2 (24x0.2 mm) MAS0175AEAAX-OIL C1101 MAS0275AEAAX-OIL C1102 MAS0575AEAAX-OIL C1103 MAS1075AEAAX-OIL C1104 MAS2075AEAAX-OIL C1105 8 40 1.5 mm 2 (7x0.53 mm) MAS0115AEAAX-OIL C1106 MAS0215AEAAX-OIL C1107 MAS0515AEAAX-OIL C1108 MAS1015AEAAX-OIL C1109 MAS2015AEAAX-OIL C1110 8 40 8 BS5308/PAS5308-2 -Type 1 & 2 - Individually & Collectively Screened - Unarmoured cables No. of Pairs 2-5 - 10-20 - Section Page 0.5 mm 2 (16x0.2 mm) MAC0250HEAAX-OIL C1111 MAC0550HEAAX-OIL C1112 MAC1050HEAAX-OIL C1113 MAC2050HEAAX-OIL C1114 8 41 0.75 mm 2 (24x0.2 mm) MAC0275HEAAX-OIL C1115 MAC0575HEAAX-OIL C1116 MAC1075HEAAX-OIL C1117 MAC2075HEAAX-OIL C1118 8 41 1.5 mm 2 (7x0.53 mm) MAC0215HEAAX-OIL C1119 MAC0515HEAAX-OIL C1120 MAC1015HEAAX-OIL C1121 MAC2015HEAAX-OIL C1122 8 41 BS5308/PAS5308-2 -Type 1 & 2 - Individually & Collectively Screened - Armoured cables No. of Pairs 2-5 - 10-20 - Section Page 0.5 mm 2 (16x0.2 mm) MAC0250AEAAX-OIL C1123 MAC0550AEAAX-OIL C1124 MAC1050AEAAX-OIL C1125 MAC2050AEAAX-OIL C1126 8 41 0.75 mm 2 (24x0.2 mm) MAC0275AEAAX-OIL C1127 MAC0575AEAAX-OIL C1128 MAC1075AEAAX-OIL C1129 MAC2075AEAAX-OIL C1130 8 41 1.5 mm 2 (7x0.53 mm) MAC0215AEAAX-OIL C1131 MAC0515AEAAX-OIL C1132 MAC1015AEAAX-OIL C1133 MAC2015AEAAX-OIL C1134 8 41

Cable Finder Control cables YY Series (N stranded cores surrounded a PVC sheath) No. of wires 3 4 5 7 12 Section Page 0.75 mm 2 (24x0.2 mm) SSS0375HBAAC C1631 SSS0475HBAAC C1635 - - - - SSS1275HBAAC C1645 9 43 1.0 mm 2 (32x0.2 mm) SSS0310HBAAC C1632 SSS0410HBAAC C1636 - - - - - - 9 43 1.5 mm 2 (30x0.24 mm) SSS0315HBAAC C1633 SSS0415HBAAC C1637 SSS0515HBAAC C1639 SSS0715HBAAC C1641 SSS1215HBAAC C1646 9 43 2.5 mm 2 (50x0.24 mm) SSS0325HBAAC C1634 SSS0425HBAAC C1638 SSS0525HBAAC C1640 SSS0725HBAAC C1642 SSS1225HBAAC C1647 9 43 CABLE FINDER CY SERIES (N stranded cores surrounded a braiding plus a PVC sheath) No. of wires 3 4 5 Section Page 0.75 mm 2 (24x0.2 mm) STS0375HBAAC C1620 STS0475HBAAC C1624 - - 9 43 1.0 mm 2 (32x0.2 mm) STS0310HBAAC C1621 STS0410HBAAC C1625 - - 9 43 1.5 mm 2 (30x0.24 mm) STS0315HBAAC C1622 STS0415HBAAC C1626 STS0515HBAAC C1628 9 43 2.5 mm 2 (50x0.24 mm) STS0325HBAAC C1623 STS0425HBAAC C1627 STS0525HBAAC C1629 9 43 9 SY Series (N stranded cores surrounded Steel Wire Armouring plus a PVC sheath) No. of wires 2 3 4 5 7 25 Section Page 0.75 mm 2 - - STS0375ABAAC C1655 - - - - - - - - 9 43 1.0 mm 2 STS0210ABAAC C1651 STS0310ABAAC C1656 STS0410ABAAC C1660 STS0510ABAAC C1665 STS0710ABAAC C1669 STS2510ABAAC C1675 9 43 No. of wires 2 3 4 5 6 18 Section Page 1.5 mm 2 STS0215ABAAC C1652 STS0315ABAAC C1657 STS0415ABAAC C1661 STS0515ABAAC C1666 STS0715ABAAC C1668 STS2515ABAAC C1674 9 43 2.5 mm 2 - - STS0325ABAAC C1658 STS0425ABAAC C1662 - - - - - - 9 43 4.0 mm 2 - - STS0340ABAAC C1659 STS0440ABAAC C1663 - - - - - - 9 43 6.0 mm 2 - - - - STS0460ABAAC C1664 - - - - - - 9 43

PAIRED CABLES SECTION 1 PVC or HFFR sheathed cables for BUS and Interface systems 1. Application RS-232, RS-422, RS-485, KNX(EIB)-bus, LonWorks, ModBus, M-Bus, CAN-bus, BACnet or general interface systems. 2. Basic Construction of the cables Wire = with or without insulation. When with insulation sometimes also indicated as core. : solid = one single rod, flexible = twisted bare or tinned copper strands, ranging from 12 to 24AWG. Conducutor (AWG) Configuration (n x AWG) Configuration (n x mm) DC Resistance (Ohm/Km) 24 7 x 32 7 x 0.20 88 22 7 x 30 7 x 0.25 57.4 20 7 x 28 7 x 0.32 37.5 18 7 x 26 7 x 0.40 22.7 16 19 x 29 19 x 0.28 15.47 14 19 x 27 19 x 0.36 9.36 10 12 19 x 25 19 x 0.45 5.61 n = number of wires in strand Insulation: Polyethylene (PE) or Foam PE (FPE) depending on the sheath material. All insulations are in accordance with BS EN 50290-2, good strippability and coloured. The colours are readily identificable and are not interchangeable. Pair = two twisted colour coded wires. Individually screened pair (if applicable): one pair wrapped with an Aluminium/Polyester drain wire under the foil. Cable core: two or more (individually screened) pairs stranded. Good twisting (lay-length < 30 40D) is necessary to ensure flexibility and avoid breaking conductors. Drain wire (only in combination with a screen): stranded tinned copper wires. In order to avoid corrosion, it is recommended that drain wires are tinned. Screen (if applicable): Helically applied (= as a spiral) Aluminium/Polyester (Alpet) foil. For the flexibility of a cable a helically applied foil is preferred as longitudinally applied foil is more difficult to bend. Braiding (if applicable): tinned copper wires. Sheath: grey PVC or purple HRRF, both in accordance with BS EN 50290-2 Cable Configuration Cable Retardancy Low Smoke Halogen-Free (non acid, non toxic) RoHS complicant PE, FPE or PVC insulation and PVC Sheath according to IEC 60332-1 No No Yes PE, FPE or HFFR insulation and HFFR sheath according to IEC 60332-3-24 according to IEC 61034-1-2 according to IEC 60754-1 & 2 Yes Operating temperature range: -25 to +75 C Rated Voltage: 300 Vrms

SECTION 1 RS-232: Hand shake interface used for low data rates. Computer to printer or to modem or to other device. Max. speed 19.2 kbit/sec. Max. distance acc. to standard 15 m. Cables used are 6 to 25 conductors. Long distance transmission requires low capacitance (standard calls for 2500 pf link), No impedance specified. RAMCRO main part numbers for RS-232: see section 1.3 RS-422: Balanced digital circuit. Medium speed data exchange. Long line modems and Daisy chain confi guration. Maximum transmission speed 10 Mbit/second (normal use under 1Mbit/sec). Max. transmission distance is 1200 metres. Ten nodes per bus. Cables used have mainly 24AWG conductors, two twisted pairs or multi-pair and Impedance of 100 Ohm. RAMCRO main part numbers for RS-422: see section 1.2 RS-485: Balanced digital circuit. Medium speed fieldbus interfaces. Maximum transmission speed 35 Mbit/second (normal use 1 or 0.5 Mbit/sec). Max. transmission distance is 1200 metres, 32 nodes per bus. Cables used have mainly 24AWG conductors, one twisted pair or multi-pair and impedance of 120 Ohm. RAMCRO main part numbers for RS-485: see section 1.1 KNX is a standardised (EN 50090, ISO/IEC 14543), OSIbased network communications protocol for intelligent buildings. KNX is the successor to, and convergence of, three previous standards: the European Home Systems Protocol (EHS), BatiBUS, and the European Installation Bus (EIB or Instabus). RAMCRO main part numbers for KNX cables: C1217-B3 (quad PVC) C1218-B3 (quad HFFR) C1219-B3 (1 pair PVC) C1220-B3 (1 pair HFFR). Modbus is a serial communications protocol published Modicon in 1979 for use with its programmable logic controllers (PLCs). Simple and robust, it has since become one of the de facto standard communications protocols in the industry. RAMCRO main part numbers for Modbus: C1197-B3 (PVC) - C1193-B3 (PVC) C1282-B3 (HFFR) C1272-B3 (HFFR). M-Bus (Meter-Bus) is a European standard (EN 13757-2 physical and link layer, EN 13757-3 application layer) for the remote reading of gas or electricity meters. M-Bus is also usable for other types of consumption meters. RAMCRO main part number for M-bus: C1020-B3 C1193-B3. Controller area network (CAN or CAN-bus) is a vehicle bus standard designed specifically for automotive applications but now also used in other areas such as industrial automation and medical equipment. CAN bus utilize TIA/EIA-485 cables. RAMCRO main part numbers for CAN-bus: C1080-B3 - C1189-B3 C1190-B3 C1191-B3 C1192-B3 C1295-B3 C1296-B3 C1297-B3 and HFFR cables C1318-B3 C1319-B3 C1320-B3 C1321-B3. BACnet is a communications protocol for building automation and control networks. It is was designed to allow communication of building automation and control systems for applications such as heating, ventilation, air-conditioning, lighting, access, and fire detection systems and their associated equipment. BACnet over IP can utilize Cat 6. RAMCRO main part numbers for BACnet:C1228 (PVC) C1189 (PVC) C1190 (PVC) - C1318 (HFFR) and C1319 (HFFR). PAIRED CABLES 11 LonWorks is a networking platform specifically created to address the needs of control applications. The platform is built on a protocol created Echelon Corporation for networking devices over media such as twisted pair, power lines, fibre optics, and RF. It is used for the automation of various functions within buildings such as lighting and HVAC. Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s). Please note that technical specifications are subject to change without notice.

PAIRED CABLES, DUAL OVERALL SCREEN SECTION 1.1 24AWG and 22AWG conductors - PE or FPE insulation - PVC or HFFR sheath for TIA/EIA-485 = RS-485 applications Product Description 1. Flexible Tinned Copper 2. Insulation Polyethylene (PE) 3. Pair Two twisted wires impedance 120 Ω 4. Tinned Copper Drain Wire 24AWG (7 x 32) 5. Screen Aluminium/Polyester > 100% Coverage 6. Braiding Tinned Copper (TC) wires 7. Sheath Material Grey PVC or Purple HFFR Standard Put Up Lenght 305 or 500 metres Standard References TIA/EIA 485 BS EN 50902-2 IEC 60332-1 (PVC sheath) or IEC 60332-3C and IEC 61034 (only HFFR cable) IEC 60754-1 & 2 (HFFR cable) RoHS directives 12 Cables with 24AWG conductors - PE insulation - PVC sheath No. of Pairs Coverage Brai ding (%) Overall Mutual Capacitance (pf/m) (Kg/ Km) MAR0108HBADX-T-B3 C1189-B3 1 90 5.9 41 49 MAR0208HBADX-T-B3 C1190-B3 2 90 8.5 41 80.5 MAR0308HBADX-T-B3 C1191-B3 3 90 9.0 41 92.6 MAR0408HBADX-T-B3 C1192-B3 4 90 9.9 41 114.4 Cables with 24AWG conductors - PE insulation - Halogen-Free (HFFR) sheath No. of Pairs Coverage Brai ding (%) Overall Mutual Capacitance (pf/m) (Kg/ Km) MAR0108HXEDX-T-B3 C1318-B3 1 90 5.9 41 49 MAR0208HXEDX-T-B3 C1319-B3 2 90 8.5 42 80.5 MAR0308HXEDX-T-B3 C1320-B3 3 90 9 42 92.6 MAR0408HXEDX-T-B3 C1321-B3 4 90 9.9 42 114.4 Cables with 22AWG conductors - Foam PE insulation - PVC sheath No. of Pairs Coverage Brai ding (%) Overall Mutual Capacitance (pf/m) (Kg/ Km) MAR0107HBADX-T-B3 C1080-B3 1 65 6.1 36 63.7 MAR0207HBADX-T-B3 C1295-B3 2 65 9.1 37 75.6 MAR0307HBADX-T-B3 C1296-B3 3 65 10.5 38 97 MAR0407HBADX-T-B3 C1297-B3 4 65 11.4 38 119.1 Colour scheme Colour scheme Pair 1 Pair 2 Pair 3 Pair 4 Wire a (insulation colour / colour of stripe) WHITE / blue WHITE / orange WHITE / green WHITE / brown Wire b (insulation colour / colour of stripe) BLUE / white ORANGE / white GREEN / white BROWN / white For more details, please see the respective detailed datasheet(s)

SECTION 1.2 2 to 6 pairs with 24AWG conductors - FPE insulation - PVC sheath for RS-422 applications Product Description 1. Flexible Tinned Copper 2. Insulation Foam Polyethylene (FPE) 3. Pair Two twisted wires 5. Screen Aluminium/Polyester Wrapped around each Pair >115% Coverage 6. Cable core 2 or more individually screened pairs stranded 7. Sheath Material Grey PVC Standard Put Up Lenght 305 or 500 metres Standard References ANSI/TIA/EIA-422-B BS EN 50290-2 IEC 60332-1 RoHS directives 4. Drain Wire Flexible Tinned Copper 24 AWG (7 x 32) Cables with 24AWG conductors - FPE insulation - PVC sheath 13 No. of Pairs and Drain Wire (AWG) No. of Strands x AWG Nominal Overall Max. DC Resistance (Ω/km) Capacitance (pf/m) Nominal Impedance (Ohm) MAP0208HBADX-T-B3 C1382-B3 2 24 7 x 32 6.7 88 41 100 41.8 MAP0308HBADX-T-B3 C1383-B3 3 24 7 x 32 8.4 88 41 100 59.4 MAP0408HBADX-T-B3 C1384-B3 4 24 7 x 32 9.2 88 41 100 75.5 MAP0608HBADX-T-B3 C1386-B3 6 24 7 x 32 10.6 88 41 100 104.8 Colour scheme Pair Number Pair 1 Pair 2 Pair 3 Pair 4 Pair 5 Pair 6 Wire a Black Black Black Black Black Black Wire b Red White Green Blue Yellow Brown For more details, please see the respective detailed datasheet(s) PAIRED CABLES

PAIRED CABLES SECTION 1.3 1 to 8 pairs with 24AWG conductors - PVC insulation - PVC sheath for TIA/EIA = RS-232 applications Product Description 1. Flexible Tinned Copper 24AWG (7x32) 2. Insulation PVC 3. Pair Two twisted wires 4. Cable core 2 or more pairs stranded 5. Tinned Copper Drain Wire 24AWG (7x32) 6. Screen Aluminium/Polyester > 115% Coverage 7. Sheath Material Grey PVC Standard Put Up Lenght 305 or 500 metres Standard References ANSI/TIA/EIA-232-F BS EN 50290-2 IEC 60332-1 RoHS directives Cables with 24AWG conductors - PVC insulation - PVC sheath - PVC sheath 14 No. of Pairs and Drain Wire (AWG) No. of Strands x AWG Nominal Overall Max. DC Resistance (Ω/km) Capacitance (pf/m) Nominal Impedance (Ohm) MAS0108HBAAH-T-B3 C1181-B3 1 24 7 x 32 4.0 88 76 75 18 MAS0208HBAAH-T-B3 C1182-B3 2 24 7 x 32 5.6 88 76 75 28 MAS0308HBAAH-T-B3 C1183-B3 3 24 7 x 32 5.9 88 76 75 39 MAS0408HBAAH-T-B3 C1184-B3 4 24 7 x 32 6.7 88 76 75 48 MAS0508HBAAH-T-B3 C1185-B3 5 24 7 x 32 7.3 88 76 75 57 MAS0608HBAAH-T-B3 C1186-B3 6 24 7 x 32 7.4 88 76 75 65 MAS0708HBAAH-T-B3 C1187-B3 7 24 7 x 32 7.5 88 76 75 73 MAS0808HBAAH-T-B3 C1188-B3 8 24 7 x 32 8.3 88 76 75 85 Cables with 24AWG conductors - HFFR insulation - HFFR sheath - PVC sheath No. of Pairs and Drain Wire (AWG) No. of Strands x AWG Nominal Overall Max. DC Resistance (Ω/km) Capacitance (pf/m) Nominal Impedance (Ohm) MAS0108HBEEH-T-B3 C1441-B3 1 24 7 x 32 4.0 88 95 75 18 MAS0208HBEEH-T-B3 C1442-B3 2 24 7 x 32 5.6 88 55 75 28 MAS0308HBEEH-T-B3 C1443-B3 3 24 7 x 32 5.9 88 55 75 39 MAS0408HBEEH-T-B3 C1444-B3 4 24 7 x 32 6.7 88 60 75 48 MAS0508HBEEH-T-B3 C1445-B3 5 24 7 x 32 7.3 88 60 75 57 MAS0608HBEEH-T-B3 C1446-B3 6 24 7 x 32 7.4 88 60 75 65 MAS0708HBEEH-T-B3 C1447-B3 7 24 7 x 32 7.5 88 60 75 73 MAS0808HBEEH-T-B3 C1448-B3 8 24 7 x 32 8.3 88 60 75 85 MAS0808HBEEH-T-B3 C1449-B3 10 24 7 x 32 9.2 88 60 75 85 Colour scheme Pair Number Pair 1 Pair 2 Pair 3 Pair 4 Pair 5 Pair 6 Pair 7 Pair 8 Wire a Black Black Black Black Black Black Black Red Wire b Red White Green Blue Yellow Brown Orange White For more details, please see the respective detailed datasheet(s)

SECTION 1.4 0.8 mm solid bare copper conductors - PE insulation - PVC or HFFR sheath for KNX (was EIB) or general bus applications Product Description 1. Solid Bare Copper 0.8 mm = 0.5 mm 2 5. Drain Wire 0.4 mm Tinned Copper 2. Insulation Polyethylene (PE) (Black-Red- White-Green) 3. Cable Core Quad or Pair 6. Screen Aluminium/Polyester Foil > 100% Coverage 7. Sheath Material Green PVC or Green HFFR 4. Polyester Foil or Tape Standard Put Up Lenght 305 or 500 metres Standard References EN 50090 BS EN 500290-2 IEC 60332-1 (PVC sheath) or IEC 60332-3C (HFFR cable) IEC 61034 (only HFFR cable) IEC 60754-1 & 2 (HFFR cable) RoHS directives PAIRED CABLES Cables with 0.8 mm conductors - PE insulation - PVC or HFFR sheath No. of wires Lay-Up Sheath Material Insulation Overall Max.DC Resistance (Ω/km) Capacitance (pf/m) 15 MAS0208HIADH-B3 C1217-B3 1 x 4 quad PVC 1.45 6.1 37 100 51 MAS0208HIEDH-B3 C1218-B3 1 x 4 quad HFFR 1.45 6.1 37 100 53 MAS0108HIADH-B3 C1219-B3 1 x 2 pair PVC 1.45 5.5 37 100 37 MAS0108HIEDH-B3 C1220-B3 1 x 2 pair HFFR 1.45 5.5 37 100 39 Colour scheme Wire a Wire b Wire c Wire d MAS0208HIADH-B3 C1217-B3 Black White Red Green MAS0208HIEDH-B3 C1218-B3 Black White Red Green MAS0108HIADH-B3 C1219-B3 Black White - - MAS0108HIEDH-B3 C1220-B3 Black White - - For more details, please see the respective detailed datasheet(s)

PAIRED CABLES, INDIVIDUALLY SCREENED PAIRS SECTION 1.5 0.64 mm solid bare copper conductors one or two individually screened pairs or pairs with no screen - HFFR sheath for LonWorks bus applications Product Description 1. Solid Bare Copper 0.64 mm = 0.32 mm 2 2. Insulation Polyethylene (PE) or Foam Polyethylne (FPE) 3. Pair with no screen Two twisted wires 4. Individually screened pair two twisted wires plus drain wire wrapped with an Aluminium coated polyester foil 5. Cable core one pair or two pairs stranded 6. Sheath Material Purple HFFR Standard Put Up Lenght 305 or 500 metres Standard References EN 50090 BS EN 50290-2 IEC 60332-3C IEC 61034 IEC 60754-1 & 2 RoHS directives Cables with 0.64 mm conductor(s) - PE or FPE insulation - HFFR sheath 16 No. of pairs Insulation Material Individually Screened Pairs Nom. Overall diameter Max. DC Resistance (Ω/km) Capacitance (pf/m) MSE0107HXEDX-B3 C1346-B3 1 PE No 3.5 61 46 17.1 MSE0207HXEDX-B3 C1347-B3 2 PE No 5.2 61 46 27.1 MAS0107HXEDX-B3 C1348-B3 1 PE Yes 4.6 61 46 24.2 MAC0207HXEDX-B3 C1349-B3 2 PE Yes 7.6 61 46 56.1 For more details, please see the respective detailed datasheet(s)

SECTION 1.6 2 to 6 pairs with 22AWG conductors - PE insulation + PVC sheath or HFFR insulation + HFFR sheath for general interface applications Product Description 1. Flexible Tinned Copper 22AWG (7X30) 2. Insulation Polyethylene (PE) or Halogen Free (HFFR) 3. Pair Two twisted wires 4. Tinned Copper Drain Wire 24AWG (7x32) 5. Screen Aluminium/Polyester foil wrapped around each pair > 115% Coverage 6. Cable core 2 or more individually screened pairs stranded 7. Sheath Material Grey PVC or Purple HFFR Standard Put Up Lenght 305 or 500 metres Standard References BS EN 50209-2 IEC 60332-1 (PVC sheath) or IEC 60332-3C (HFFR cable) IEC 61034 (HFFR cable) IEC 60754-1 & 2 (HFFR cable) RoHS directives PAIRED CABLES, INDIVIDUALLY SCREENED PAIRS Cables with 22AWG conductors - PE or HFFR insulation - PVC OR HFFR sheath No. of pairs Insulation Material Sheath Material Overall diameter Max. DC Resistance (Ω/km) Capacitance (pf/m) 17 MAP0207HBADX-T-B3 C1196-B3 2 PE PVC 6.0 57.4 90 49.9 MAP0207HBEDX-T-B3 C1281-B3 2 HFFR HFFR 6.5 57.4 90 50.8 MAP0307HBADX-T-B3 C1197-B3 3 PE PVC 6.5 57.4 98 52.7 MAP0307HBEDX-T-B3 C1282-B3 3 HFFR HFFR 7.5 57.4 92 67.4 MAP0607HBADX-T-B3 C1214-B3 6 PE PVC 8.9 57.4 99 104.2 MAP0607HBEDX-T-B3 C1314-B3 6 HFFR HFFR 9.5 57.4 92 115.6 Colour scheme Pair Cable Pair 1 Pair 2 Pair 3 Pair 4 Pair 5 Pair 6 MAP0207HBADX-T-B3 and MAP0207HBEDX-T-B3 MAP0307HBADX-T-B3 and MAP0307HBEDX-T-B3 C1196- B3 and C1281-B3 C1197- B3 and C1282-B3 Black / Red Green / White - - - - Black / Red Black / White Black / Green - - - MAP0607HBADX-T-B3 and MAP0607HBEDX-T-B3 C1214- B3 and C1314-B3 For more details, please see the respective detailed datasheet(s) Black / Red Black / White Black / Green Black / Blue Black / Yellow Black / Brown

PAIRED CABLES SECTION 1.7 One pair cables with 22 to 12AWG conductors; PE insulation - PVC sheath or HFFR insulation - HFFR sheath for general interface applications Product Description 1. Flexible Tinned Copper 2. Insulation PVC or Polyethylene (PE) or Halogen-Free (HFFR) 3. Pair Two twisted wires 4. Tinned Copper Drain Wire (only with screen) 24AWG (7x32) 5. Screen (if applicable) Aluminium/Polyester > 115% Coverage 6. Sheath Material Grey PVC or Purple HFFR Standard Put Up Lenght 305 or 500 metres Standard References BS EN 50290-2 IEC 60332-1 (PVC sheath) IEC 60332-3c (HFFR cable) IEC 61034 (HFFR cable) IEC 60754-1 & 2 (HFFR cable) RoHS directives 18 DC Resistance 24 to 12AWG conductors size AWG 24 22 20 18 16 14 12 No. of strands x guage n x AWG 7 x 32 7 x 30 7 x 28 7 x 26 19 x 29 19 x 27 19 x 25 No. of strands x mm n x mm 7 x 0.20 7 x 0.25 7 x 0.325 7 x 0.40 19 x 0.29 19 x 0.38 19 x 0.48 Max. DC Resistance conductor (Ω/km) 88 57.4 35.75 22.7 15.47 9.36 5.61 n = number of wires in strand One pair screened cables with PE insulation, PVC sheath One pair screened cables with HFFR insulation and HFFR sheath (AWG) Overall Capacitance (pf/m) (AWG) Overall Capacitance (pf/m) MAS0107HBADN-T-B3 C1199-B3 22 4.4 75 25 MAS0106HBADN-T-B3 C1195-B3 20 5.0 75 36.4 MAS0105HBADN-T-B3 C1193-B3 18 5.6 75 43.2 MAS0103HBADN-T-B3 C1213-B3 16 7.9 60 75.7 MAS0101HBADN-T-B3 C1224-B3 14 9.0 76 104.9 MAS0152HBADN-T-B3 C1313-B3 12 10.2 77 124.7 MAS0107HXEDN-T-B3 C1310-B3 22 4.5 140 27.1 MAS0106HXEDN-T-B3 C1308-B3 20 5.3 120 37.2 MAS0105HXEDN-T-B3 C1272-B3 18 6.0 120 48.4 MAS0103HXEDN-T-B3 C1270-B3 16 7.8 110 74.3 MAS0101HXEDN-T-B3 C1305-B3 14 8.8 110 97.9 MAS0152HXEDN-T-B3 C1303-B3 12 9.9 110 132.6 One pair underscreened cables with PE insulation and PVC sheath (AWG) Overall Capacitance (pf/m) One pair unscreened cables with HFFR insulation and HFFR sheath (AWG) Overall Capacitance (pf/m) MSE0107HBADN-T-B3 C1301-B3 22 4.0 70 19.5 MSE0106HBADN-T-B3 C1300-B3 20 4.3 70 23 MSE0105HBADN-T-B3 C1203-B3 18 5.1 70 38.6 MSE0103HBADN-T-B3 C1198-B3 16 6.9 50 63.3 MSE0101HBADN-T-B3 C1222-B3 14 8.6 108 91.8 MSE0152HBADN-T-B3 C1302-B3 12 9.8 115 115 MSE0107HXEDN-T-B3 C1311-B3 22 4.4 85 24.7 MSE0106HXEDN-T-B3 C1309-B3 20 5.2 80 34.7 MSE0105HXEDN-T-B3 C1271-B3 18 5.9 80 45.9 MSE0103HXEDN-T-B3 C1307-B3 16 7.7 75 71.8 MSE0101HXEDN-T-B3 C1306-B3 14 8.7 75 95.3 MSE0152HXEDN-T-B3 C1304-B3 12 9.8 75 128.2 For more details, please see the respective detailed datasheet(s)

SECTION 1.8 1 to 6 pairs with 18AWG conductors - Polyolefin insulation - Collective Screen and Halogen-Free (HFFR) sheath Product Description 1. Flexible Bare Copper 2. Insulation Polyolefin 3. Pair Two twisted wires 4. Cable core Pairs stranded 5. Drain Wire Flexible Tinned Copper 24AWG (7X32) 6. Collective Screen Aluminium/Polyester > 115% Coverage 7. Sheath Material Purple HFFR Standard Put Up Lenght 305 or 500 metres Standard References (BS) EN 50209-2 IEC 60332-3-24 IEC 61034 IEC 60754-1 & 2 RoHS directives Cables with 18AWG conductors - Polyolefin insulation - Collective Screen and HFFR sheath No. of pairs (AWG) Configuration (n x AWG) Max. DC Resistance (Ω/ km) Overall Capacitance (pf/m) 19 MAS0105HXEDX-T-B3 C1171-B3 1 18 7 x 26 22.7 5.1 115 4.1 MAS0205HXEDX-T-B3 C1172-B3 2 18 7 x 26 22.7 7.7 115 7.41 MAS0305HXEDX-T-B3 C1173-B3 3 18 7 x 26 22.7 8.1 115 9.64 MAS0405HXEDX-T-B3 C1174-B3 4 18 7 x 26 22.7 8.9 115 12.37 MAS0505HXEDX-T-B3 C1175-B3 5 18 7 x 26 22.7 9.9 115 14.92 MAS0605HXEDX-T-B3 C1176-B3 6 18 7 x 26 22.7 10.2 115 17.11 n = number of wires in strand Colour scheme Pair Number Pair 1 Pair 2 Pair 3 Pair 4 Pair 5 Pair 6 Wire a Black Black Black Black Black Black Wire b Red White Green Blue Yellow Brown For more details, please see the respective detailed datasheet(s) PAIRED CABLES

MULTI-CONDUCTOR CABLES SECTION 2 APPLICATION AND CONSTRUCTION 1. Application All PVC and HFFR sheathed multi-conductor cables are suitable for Building Management Systems (BMS), Sound, Audio, Security, Safety, Control and Instrumentation. 2. Basic Construction of the cables Wire = with or without insulation. When with insulation sometimes also indicated as core. : flexible = twisted bare or tinned copper strands, ranging from 12 to 22AWG. (AWG) Configuration (n x AWG) Configuration (n x mm) DC Resistance (Ohm/km) 24 7 x 32 7 x 0.20 88 22 7 x 30 7 x 0.25 57.4 20 7 x 28 7 x 0.32 35.75 18 7 x 26 7 x 0.40 22.7 16 19 x 29 19 x 0.28 15.47 14 19 x 27 19 x 0.36 9.36 20 12 19 x 25 19 x 0.45 5.61 n= number of wires in strand Insulation: Polypropylene (PP) for PVC (Polyvinyl Chloride) sheathed cables and Halogen-Free (HFFR) for HFFR sheathed cables. Both insulations are in accordance with BS EN 50290-2. Good strippability and coloured insulation. The colours are readily identificable and are not interchangeable. Colour scheme of wires with 12 or 14AWG conductors: black-white-red-green-brown-blue-orange-yellow-purple-grey-pink-tan. Colour scheme of wires with 16AWG conductors: black-red-white-green-brown-blue-orange-yellow-purplegrey-pink-tan. Cable core: two or more wires, twisted. Good twisting (lay-length < 30 40D) is necessary to ensure flexibility and avoid breaking conductors. Drain wire (only in combination with a screen): stranded tinned copper wires. In order to avoid corrosion, it is recommended that drain wires are tinned. Screen (if applicable): Helically applied (= as a spiral) Aluminium/Polyester (Alpet) foil. For the flexibility of a cable a helically applied foil is preferred as longitudinally applied foil is more difficult to bend. Sheath: grey PVC or purple HFFR or black UV-resistant HFFR, all in accordance with BS EN 50290-2. Cable configuration Cables with PVC sheath Halogen-Free cables Insulation Sheath PP acc. to BS EN 50290-2 HFFR acc.to BS EN 50290-2 HFFR acc. to BS EN 50290-2 HFFR acc. to BS EN 50290-2 Retardancy Flame Retardant Fire Retardant Retardant acc. to IEC 60332-1 / UL1581 IEC 60332-3-24 / UL1685 Low Smoke emission acc. to Not Applicable IEC 61034 Halogen-Free acc. to Not Applicable IEC 60754 RoHS complicant Yes Yes Operating temperature range: -25 to +75 C Rated Voltage: 300 Vrms. Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s). Please note that technical specifications are subject to change without notice.

SECTION 2.1 PVC sheathed cables with 22AWG to 12AWG conductors for Audio, Control, Instrumentation and Building Management System (BMS) Product Description 1. Stranded Bare Copper 2. Insulation Polypropylene (PP) 3. Cable core Two or more twisted wires stranded 4. Drain Wire (only with screen) 24AWG (7X32) Tinned Copper 5. Screen (if applicable) Aluminium/Polyester >100% Coverage 6. Sheath Material Grey PVC Standard Put Up Lenght 305 and 500 meters Standard References BS EN 50290-2 IEC 60332-1 RoHS directives MULTI-CONDUCTOR CABLES No. of wires (AWG) B3 number Screen B3 number Screen 2 22 SAS0207HBAXH-B3 C1226-B3 Yes 3.3 16.5 SSS0207HBAXH-B3 C1227-B3 No 3.3 14.6 3 22 4 22 SAS0307HBAXX-B3 C1228-B3 Yes 3.5 21.4 SAS0407HBAXX-B3 C1230-B3 Yes 3.8 26.0 SSS0307HBAXX-B3 C1278-B3 No 3.5 19.7 SSS0407HBAXX-B3 C1231-B3 No 3.8 23.9 21 6 22 SAS0637HBAXX-B3 C1264-B3 Yes 4.5 35.7 SSS0607HBAXX-B3 C1265-B3 No 4.5 33.6 8 22 SAS0837HBAXX-B3 C1232-B3 Yes 4.9 45.1 SSS0807HBAXX-B3 C1233-B3 No 4.9 43 2 20 SAS0206HBAXH-B3 C1019-B3 Yes 3.5 22.0 SSS0206HBAXH-B3 C1020-B3 No 3.4 19.7 3 20 SAS0306HBAXX-B3 C1021-B3 Yes 3.7 28.5 SSS0306HBAXX-B3 C1022-B3 No 3.6 26.2 4 20 SAS0406HBAXX-B3 C1023-B3 Yes 4.1 35.4 SSS0406HBAXX-B3 C1024-B3 No 4.0 33.1 6 20 SAS0606HBAXX-B3 C1260-B3 Yes 5.0 49.9 SSS0606HBAXX-B3 C1261-B3 No 4.9 47.9 8 20 SAS0806HBAXX-B3 C1262-B3 Yes 5.4 62.9 SSS0806HBAXX-B3 C1263-B3 No 5.3 60.6 2 18 SAS0205HBAXH-B3 C1013-B3 Yes 4.0 29.6 SSS0205HBAXH-B3 C1014-B3 No 3.9 27.3 3 18 SAS0305HBAXX-B3 C1015-B3 Yes 4.2 39.2 SSS0305HBAXX-B3 C1016-B3 No 4.1 36.9 4 18 SAS0405HBAXX-B3 C1017-B3 Yes 4.6 49.4 SSS0405HBAXX-B3 C1018-B3 No 4.55 47.2 6 18 SAS0605HBAXX-B3 C1211-B3 Yes 5.75 70.9 SSS0605HBAXX-B3 C1212-B3 No 5.7 68.2 8 18 SAS0805HBAXX-B3 C1258-B3 Yes 6.0 89.5 SSS0805HBAXX-B3 C1259-B3 No 5.9 87 2 16 SAS0203HBAXH-B3 C1007-B3 Yes 4.6 37.3 SSS0203HBAXH-B3 C1008-B3 No 4.5 35 3 16 SAS0303HBAXX-B3 C1009-B3 Yes 4.9 50.0 SSS0303HBAXX-B3 C1010-B3 No 4.75 47.7 4 16 SAS0403HBAXX-B3 C1011-B3 Yes 5.3 63.5 SSS0403HBAXX-B3 C1012-B3 No 5.25 61.1 6 16 SAS0603HBAXX-B3 C1252-B3 Yes 6.8 91.6 SSS0603HBAXX-B3 C1253-B3 No 6.7 89 8 16 SAS0803HBAXX-B3 C1254-B3 Yes 7.6 120.8 SSS0803HBAXX-B3 C1255-B3 No 7.5 118.1 2 14 SAS0201HBAXH-B3 C1001-B3 Yes 6.0 57.0 SSS0803HBAXX-B3 C1002-B3 No 5.75 53.3 3 14 SAS0301HBAXX-B3 C1003-B3 Yes 6.5 77.9 SSS0301HBAXX-B3 C1004-B3 No 6.35 72.5 4 14 SAS0401HBAXX-B3 C1005-B3 Yes 6.9 102.5 SSS0401HBAXX-B3 C1006-B3 No 6.75 97.1 6 14 SAS0601HBAXX-B3 C1248-B3 Yes 8.6 151.0 SSS0601HBAXX-B3 C1249-B3 No 8.4 148.2 8 14 SAS0801HBAXX-B3 C1250-B3 Yes 9.8 197.3 SSS0801HBAXX-B3 C1251-B3 No 9.7 194.5 2 12 SAS0252HBAXH-B3 C1322-B3 Yes 6.9 85.7 SSS0252HBAXH-B3 C1323 No 6.7 79.8 3 12 SAS0352HBAXX-B3 C1324-B3 Yes 7.4 118.1 SSS0352HBAXX-B3 C1325 No 7.2 112.1 4 12 SAS0452HBAXX-B3 C1326-B3 Yes 8.2 151.1 SSS0452HBAXX-B3 C1327 No 8.0 145.3 6 12 SAS0652HBAXX-B3 C1330-B3 Yes 9.8 215.5 SSS0652HBAXX-B3 C1331 No 9.6 209.7 8 12 SAS0852HBAXX-B3 C1332-B3 Yes 10.7 279.5 SSS0852HBAXX-B3 C1333 No 10.5 273.7 For more details, please see the respective detailed datasheet(s)

MULTI-CONDUCTOR CABLES SECTION 2.2 PVC sheathed cables with 22AWG to 12AWG conductors for Audio, Control, Instrumentation and Building Management System (BMS) Product Description 1. Stranded Bare Copper 2. Insulation Polyolefine 3. Drain Wire (Only with screen) 24AWG (7x32) Tinned Copper 4. Screen (if applicable) Aluminium/Polyester >100% Coverage 5. Ripcord 6. Sheath Material Purple HFFR Standard Put Up Lenght 305 metres Standard References BS EN 50290-2 IEC 60332-3C IEC 61034 IEC 60754-1 & 2 RoHS directives No. of wires (AWG) Screen Screen 2 22 SAS0207HXEDH-B3 C1741-B3 Yes 3.9 22.4 SSS0207HXEDH-B3 C1742-B3 No 3.9 20.5 22 3 22 4 22 6 22 SAS0307HXEDX-B3 C1743-B3 Yes 4.1 27.6 SAS0407HXEDX-B3 C1745-B3 Yes 4.4 33.7 SAS0607HXEDX-B3 C1747-B3 Yes 5.2 45.8 SSS0307HXEDX-B3 C1744-B3 No 4.1 26 SSS0407HXEDX-B3 C1746-B3 No 4.4 31.7 SSS0607HXEDX-B3 C1748-B3 No 5.2 43.9 8 22 SAS0807HXEDX-B3 C1749-B3 Yes 5.6 56.4 SSS0807HXEDX-B3 C1750-B3 No 5.6 54.4 2 20 SAS0206HXEDH-B3 C1731-B3 Yes 4.7 32.6 SSS0206HXEDH-B3 C1732-B3 No 4.6 30.1 3 20 SAS0306HXEDX-B3 C1733-B3 Yes 4.9 40.2 SSS0306HXEDX-B3 C1734-B3 No 4.8 37.7 4 20 SAS0406HXEDX-B3 C1735-B3 Yes 5.3 48.7 SSS0406HXEDX-B3 C1736-B3 No 5.2 46.2 6 20 SAS0606HXEDX-B3 C1737-B3 Yes 6.2 66.2 SSS0606HXEDX-B3 C1738-B3 No 6.1 63.7 8 20 SAS0806HXEDX-B3 C1739-B3 Yes 6.7 81.9 SSS0806HXEDX-B3 C1740-B3 No 6.6 79.4 2 18 SAS0205HXEDH-B3 C1721-B3 Yes 5.1 41 SSS0205HXEDH-B3 C1722-B3 No 5 38.5 3 18 SAS0305HXEDX-B3 C1723-B3 Yes 5.4 52.3 SSS0305HXEDX-B3 C1724-B3 No 5.3 49.8 4 18 SAS0405HXEDX-B3 C1725-B3 Yes 5.8 64.1 SSS0305HXEDX-B3 C1726-B3 No 5.7 61.6 6 18 SAS0605HXEDX-B3 C1727-B3 Yes 6.8 88.6 SSS0605HXEDX-B3 C1728-B3 No 6.7 86.1 8 18 SAS0805HXEDX-B3 C1729-B3 Yes 7.3 110.8 SSS0805HXEDX-B3 C1730-B3 No 7.2 108.2 2 16 SAS0203HXEDH-B3 C1711-B3 Yes 5.4 49.3 SSS0203HXEDH-B3 C1712-B3 No 5.4 46.8 3 16 SAS0303HXEDX-B3 C1713-B3 Yes 5.7 63.8 SSS0303HXEDX-B3 C1714-B3 No 5.7 61.3 4 16 SAS0403HXEDX-B3 C1715-B3 Yes 6.2 79.3 SSS0403HXEDX-B3 C1716-B3 No 6.2 78.2 6 16 SAS0603HXEDX-B3 C1717-B3 Yes 7.3 108.2 SSS0603HXEDX-B3 C1718-B3 No 7.3 107 8 16 SAS0803HXEDX-B3 C1719-B3 Yes 7.9 137 SSS0803HXEDX-B3 C1720-B3 No 7.9 135.9 2 14 SAS0201HXEDH-B3 C1701-B3 Yes 6.5 67.7 SSS0201HXEDH-B3 C1702-B3 No 6.4 65.2 3 14 SAS0301HXEDX-B3 C1703-B3 Yes 6.9 92.8 SSS0301HXEDX-B3 C1704-B3 No 6.8 89.1 4 14 SAS0401HXEDX-B3 C1705-B3 Yes 7.5 115.4 SSS0401HXEDX-B3 C1706-B3 No 7.4 112.9 6 14 SAS0601HXEDX-B3 C1707-B3 Yes 8.9 163.7 SSS0601HXEDX-B3 C1708-B3 No 8.8 162.8 8 14 SAS0801HBHXX-B3 C1709-B3 Yes 9.6 210.8 SSS0801HXEDX-B3 C1710-B3 No 9.5 208.3 2 12 SAS0252HXEDH-B3 C1334-B3 Yes 7.7 102.2 SSS0252HXEDH-B3 C1335-B3 No 7.5 97 3 12 SAS0352HXEDX-B3 C1336-B3 Yes 8.1 135 SSS0352HXEDX-B3 C1337-B3 No 7.9 129.7 4 12 SAS0452HXEDX-B3 C1338-B3 Yes 8.9 170.9 SSS0452HXEDX-B3 C1339-B3 No 8.7 165.7 6 12 SAS0652HXEDX-B3 C1342-B3 Yes 10.6 243.3 SSS0652HXEDX-B3 C1343-B3 No 10.4 237.1 8 12 SAS0852HXEDX-B3 C1344-B3 Yes 11.6 314.6 SSS0852HXEDX-B3 C1345-B3 No 11.4 306.2 For more details, please see the respective detailed datasheet(s)

SECTION 2.3 UV-Resistant Halogen-Free (HFFR) cables with 18AWG to 16AWG conductors for Audio, Control, Instrumentation and Building Management Systems (BMS) Product Description 1. Stranded Bare Copper 2. Insulation HFFR 3. Drain Wire (only with screen) 24AWG (7x32) Tinned Copper 4. Screen Aluminium/Polyester > 100% Coverage 5. Ripcord 6. Sheath Material Black UV-resistant HFFR Standard Put Up Lenght 305 meters Standard References BS EN 50290-2 IEC 60332-3C IEC 61034 IEC 60754-1 & 2 RoHS directives MULTI-CONDUCTOR CABLES Physical Characteristics of 18AWG No. of wires (AWG) 2 18 3 18 4 18 6 18 8 18 10 18 20 18 Screen SAS0205HBOXH-B3 C1351-B3 Yes 5.1 41 SAS0305HBOXH-B3 C1352-B3 Yes 5.4 52.3 SAS0405HBOXH-B3 C1353-B3 Yes 5.8 64.1 SAS0605HBOXH-B3 C1354-B3 Yes 6.8 88.6 SAS0805HBOXH-B3 C1355-B3 Yes 7.3 110.8 SAS1005HBOXH-B3 C1356-B3 Yes 8.4 135.7 SAS2005HBOXH-B3 C1357-B3 Yes 10.7 249.6 23 Physical Characteristics of 16AWG No. of wires (AWG) Screen 2 16 3 16 4 16 6 16 8 16 10 16 20 16 SAS0203HBOXH-B3 C1391-B3 Yes 5.5 49.3 SAS0303HBOXH-B3 C1392-B3 Yes 5.8 63.8 SAS0403HBOXH-B3 C1393-B3 Yes 6.3 79.3 SAS0603HBOXH-B3 C1394-B3 Yes 7.4 108.2 SAS0803HBOXH-B3 C1395-B3 Yes 8 137 SAS1003HBOXH-B3 C1396-B3 Yes 9.5 173.1 SAS2003HBOXH-B3 C1397-B3 Yes 12.1 316.6 For more details, please see the respective detailed datasheet(s)

FIRE DETECTION AND ALARM SYSTEM CABLES SECTION 3 Bare Copper 18 to 12AWG, one pair, PVC insulation and Sheath, Screened and Unscreened Application Fire Detection and Alarm Systems Fire Retardancy: UL 1666 Product Description 1. Solid Bare Copper 2. Insulation PVC HT 105 Black and Red 3. Pair Two wires twisted 4. Tinned Copper Drain Wire (only under screen) 22AWG (7x30) 5. Screen (if applicable) Aluminium/Polyester > 100% Coverage 6. Sheath Material Red PVC Standard Put Up Lenght 305 metres Standard References UL1424 UL1666 RoHS directives 24 B3 Number No. of pairs (AWG) Screen Overall Max. DC resistance conductor (Ω/km) Capacitacne (pf/m) SAR0203HFCCH-B3 C1040-B3 1 18 Yes 5.9 22.7 160 19.2 SSR0203HFCCH-B3 C1135-B3 1 18 No 5.8 22.7 60 16 SAR0202HFCCH-B3 C1041-B3 1 16 Yes 6.1 15.47 189 28.5 SSR0202HFCCH-B3 C1136-B3 1 16 No 6.0 15.47 71 25.0 SAR0201HFCCH-B3 C1042-B3 1 14 Yes 7.8 9.36 160 43.0 SSR0201HFCCH-B3 C1137-B3 1 14 No 7.7 9.36 69 40.0 SAR0252HFCCH-B3 C1043-B3 1 12 Yes 8.7 5.61 216 66.0 SSR0252HFCCH-B3 C1138-B3 1 12 No 8.6 5.61 65 63.0 Operating temperature range: -40 to +105 C Rated Voltage: 300 Vrms Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s). Please note that technical specifications are subject to change without notice.

SECTION 4 Bare and Flexible Copper s 0.75 to 4.0 mm2, Silicon insulation and Halogen-free Sheath, Screened and Unscreened 1. Application All Fire Resistant cables are suitable for Security, Safety, Control and Instrumentation with special requirements for circuit integrity in case of a fire. 2. Fire Resistance conforming with BS6387 CWZ: Fire Resistant to BS6386, Cat. C: exposed to fire at 950 C for 3 hours Fire Resistant to BS6387, Cat. W: exposed to fire at 650 C for 15 minutes, then exposed to fire at 650 C with water for 15 minutes Fire Resistant to BS6387, Cat. Z: exposed to fire at 650 C for 15 minutes, then exposed to fire at 650 C with mechanical shock for 15 minutes FIRE RESISTANT CABLES 3. Fire Retardancy conforming with IEC 60332-3-24 4. Basic Construction of the cables Wire = with Insulation : solid or flexible (= stranded) bare copper wires, ranging from 0.75 to 4 mm2. Cross Section (mm 2 ) Construction (n x mm) DC Resistance (Ohm/km) Recommended Current (Amp) 0.75 1 x 1.0 1.0 24.5 12 25 1.0 1 x 1.13 1.13 18.1 18 1.5 1 x 1.4 1.4 12.1 21 2.5 1 x 1.8 1.8 7.41 30 4.0 7 x 0.85 2.55 4.61 40 n = number of wires in strand Insulation: Silicon Rubber blends acc. to BS 7655. Good strippable and coloured insulation. The colours are not interchangeable. Colour scheme: blue brown. Cable core: two or more wires, twisted. Good twisting is necessary to ensure flexibility and avoid breaking conductors. Drain wire (only in combination with a screen): solid bare copper. Screen (if applicable): Helically applied (= as a spiral) Aluminium/Polyester (Alpet) foil. For the flexibility of a cable a helically applied foil is preferred as longitudinally applied foil is more difficult to bend. Sheath: red HFFR in accordance with BS EN 50290-2 Operating temperature range: -20 to +90 C. Rated Voltage: 300/500 Vrms Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s). Please note that technical specifications are subject to change without notice.

FIRE DETECTION CABLES SECTION 4 Product Description 1. Solid or Flexible Bare Copper 2. Insulation Silicon Rubber Blend 3. Cable core Two or three wires Twisted 4. BC Drain Wire Bare Copper (only under screen) 5. Screen (if applicable) Aluminium/Polyester > 100% Coverage 6. Sheath Material Red HFFR Standard Put Up Lenght 305 and 500 meters Standard References BS 6387 CWZ BS 7655 IEC 60332-3C IEC 60754-1 & 2 RoHS directivies No. of wires (mm 2 ) Screen Drain Wire Overall Max. DC Resistance (Ω/km) SAR0210HFESL-F3 C1284-B3 2 0.75 Yes 0.75 7.5 24.5 67.0 26 SSR0210HFESL-F3 C1139-B3 2 0.75 No - 7.4 24.5 61.7 SAR0310HFESL-F3 C1159-B3 3 0.75 Yes 0.75 7.9 24.5 83 SSR0310HFESL-F3 C1149-B3 3 0.75 No - 7.8 24.5 75 SAR0211HFESL-F3 C1283-B3 2 1.0 Yes 1.0 7.8 18.1 73.4 SSR0211HFESL-F3 C1140-B3 2 1.0 No - 7.7 18.1 65.5 SAR0311HFESL-F3 C1160-B3 3 1.0 Yes 1.0 8.1 18.1 93 SSR0311HFESL-F3 C1150-B3 3 1.0 No - 8.0 18.1 83 SAR0214HFESL-F3 C1044-B3 2 1.5 Yes 1.5 8.7 12.1 98.1 SSR0214HFESL-F3 C1141-B3 2 1.5 No - 8.6 12.1 87.6 SAR0314HFESL-F3 C1161-B3 3 1.5 Yes 1.5 8.95 12.1 123 SSR0314HFESL-F3 C1151-B3 3 1.5 No - 8.85 12.1 108 SAR0218HFESL-F3 C1045-B3 2 2.5 Yes 2.5 9.9 7.41 134.3 SSR0218HFESL-F3 C1142-B3 2 2.5 No - 9.8 7.41 119.4 SAR0318HFESL-F3 C1162-B3 3 2.5 Yes 2.5 10.3 7.41 174 SSR0318HFESL-F3 C1152-B3 3 2.5 No - 10.2 7.41 151 SAS0240HFESL-F3 C1289-B3 2 4.0 Yes 4.0 12.0 4.61 197.1 SSS0240HFESL-F3 C1143-B3 2 4.0 No - 11.9 4.61 172.6 SAS0340HFESL-F3 C1163-B3 3 4.0 Yes 4.0 12.95 4.61 270 SSS0340HFESL-F3 C1153-B3 3 4.0 No - 12.85 4.61 234 For more details, please see the respective detailed datasheet(s)

SECTION 5 Application and construction of Coax Cables for 75 Ohm Video Systems Applications CCTV: Closed Circuit Television uses video cameras to transmit a signal to a specific place, on a limited set of monitors SMATV: Satellite Master Antenna Television used to deliver signals to multiple dwelling units (e.g., apartment buildings and trailer parks). CATV: Central Antenna Television = Cable television is a system of providing television to consumers via radio frequency signals transmitted to televisions. Nowadays also used for internet and telephone. HDTV: High-definition television refers to video having resolution substantially higher than traditional television systems. Telecom and networking: a number of special cable constructions. Basic Cable Design Coaxial cables are designed to carry radio frequency signals of a much higher frequency than the 50 or 60 Hz used in low voltage cables. This requires special construction to prevent power losses. If an ordinary wire is used to carry high frequency signals, the wire acts as an antenna, and the high frequency signals radiate off the wire as radio waves, causing power losses. To prevent this, in coaxial cable one of the conductors is formed into a tube and encloses the other conductor. This confines the radio waves from the central conductor to the space inside the tube. To prevent the outer conductor, or shield, from radiating, it is connected to electrical ground, keeping it at a constant potential. The dimensions and spacing of the conductors must be uniform throughout the length of the cable. Any abrupt change in the spacing of the two conductors along the cable tends to reflect radio frequency power back toward the source. This acts as a bottleneck, reducing the amount of power reaching the destination end of the cable. COAX CABLES 27 Choosing the correct 75 ohm coax cable. Most coaxial cables for video applications have a nominal impedance of 75 ohms. Their differing electrical and physical characteristics make it important to select the correct type of cable to suit the application. Analogue TV CCTV This table is for reference only. RG59 RG6 RG11 RG59 RG6 RG11 Acceptable performance on cable runs < 225 metres Gives superior performance in cable runs < 225 metres. Used for cable runs < 225 metres but < 545 metres For cable runs greater than 545 metres Acceptable performance on cable runs < 225 metres Gives superior performance in cable runs < 225 metres. Used for cable runs < 225 metres but < 545 metres For cable runs greater than 545 metres Summary of B3 Italy Numbers. Application Tested Speciality RG-59 RG-6 RG-11 CCTV - PVC Sheath 1000 MHz Solid RG59 C1028-B3 RG6 C1029-B3 RG11 C1030-B3 CCTV - HRRR Sheath 1000 MHz Solid RG59-ZA C1428-B3 RG6-ZA C1429-B3 RG11-ZA C1430-B3 CCTV 1000 MHz Flexible RG59-FLEX C1275-B3 RG6-FLEX C1276-B3 RG11-FLEX C1277-B3 CATV / SMATV 3000 MHz Dual Screen RG59-FA C1025-B3 RG6-FA C1026-B3 RG11-FA C1027-B3 CATV / SMATV 3000 MHz Dual Screen RG59-QS C1256-B3 RG6-QS C1257-B3 RG11-QS C1241-B3 HDTV - PVC Sheath 4500 MHz Dual Screen 95% RG59-FTC C1229-B3 RG6-FTC C1279-B3 RG11-FTC C1280-B3 HDTV - HFFR Sheath 4500 MHz Dual Screen 95% RG59-ZA-FTC C1378-B3 RG6-ZA-FTC C1379-B3 RG11-ZA-FTC C1380-B3 Operating temperature range: -25 to +75 C Rated Voltage: 300 Vrms Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s). Please note that technical specifications are subject to change without notice.

SECTION 5.1 COAX CABLES CCTV and Video Applications, sweep tested 1 to 100 MHz Product description 1. Solid or Flexible Bare Copper 2. Insulation Foamed Polyethylene (FPE) 3. Braid Bare Copper 4. Sheath Material Polyvinyl Chloride (PVC) or Halogen-Free (HFFR) Standard Put Up Lenght 305 or 500 metres Standard References IEC 61196 BS EN 50117 BS EN 50290-2 IEC 60332-1 (PVC SHEATH) or IEC 60332-3-24 (HFFR cable) IEC 61034 (only HFFR cable) IEC 60754-1 & 2 (HFFR cable) RoHS directives Physical Characteristics 28 RG-Type Diametic over Dieletric Coverage Braid (%) Sheath Material Overall (kg / km) RG59 C1028-B3 RG-59 0.81 3.71 95 PVC 6.0 47.12 RG59-ZA C1428-B3 RG-59 0.81 3.71 95 HFFR 6.0 48.5 RG59-FLEX C1275-B3 RG-59 19x0.18 TC 3.71 95 PVC 6.0 47.12 RG6 C1029-B3 RG-6 1.02 4.60 95 PVC 6.8 55.5 RG6-ZA C1429-B3 RG-6 1.02 4.60 95 HFFR 6.8 58.2 RG6-FLEX C1276-B3 RG-6 19x0.22 4.60 95 PVC 6.8 54.66 RG11 C1030-B3 RG-11 1.63 7.11 95 PVC 10.0 115.9 RG11-ZA C1430-B3 RG-11 1.63 7.11 95 HFFR 10.0 120 RG11-FLEX C1277-B3 RG-11 19x0.34 7.11 95 PVC 10.0 115.9 Electrical and Physical Characteristics (at 20 C) RG-Type Impedance (Ω) Max. DC Resistance (Ω / km) Max. DC Screen Resistance (Ω / km) Nominal Capacitance (pf / m) Min. Return Loss 1 to 1000 MHz RG59 C1028-B3 RG-59 75 ± 3 33.5 10.1 53.5 20 RG59-ZA C1428-B3 RG-59 75 ± 3 33.5 10.1 53.5 20 RG59-FLEX C1275-B3 RG-59 75 ± 3 40 10.1 53.5 20 RG6 C1029-B3 RG-6 75 ± 3 21.5 10.8 53.5 20 RG6-ZA C1429-B3 RG-6 75 ± 3 21.5 10.8 53.5 20 RG6-FLEX C1276-B3 RG-6 75 ± 3 30 10.8 53.5 20 RG11 C1030-B3 RG-11 75 ± 3 8.8 6.5 52.8 20 RG11-ZA C1430-B3 RG-11 75 ± 3 8.8 6.5 52.8 20 RG11-FLEX C1277-B3 RG-11 75 ± 3 8.8 6.5 52.8 20 Nominal attenuation in db/100 m MHz 5 10 50 100 200 300 400 450 550 700 750 870 1000 RG-59 1.9 2.95 6.23 8.53 11.81 15.3 16.41 18.92 21.03 22.97 24.8 26.84 27.89 RG-6 1.78 2.36 4.92 6.56 9.51 12.43 13.78 15.14 17.15 18.37 19.73 20.26 21.96 RG-11 0.99 1.51 2.96 4.27 6.23 8.27 9.51 10.31 11.51 13.45 13.95 14.87 17.06 For more details, please see the respective detailed datasheet(s)

SECTION 5.2 SMATV - CATV and Video applications, sweep tested 1 to 3000 MHz Product Description 1. Solid Copper Covered Steel (CCS) 2. Insulation Foamed Polyethylene (FPE) 3. Screen 1 Bonded Aluminium/Polyester foil 100% coverage 4. Braid 1 Alluminum 5. Braid 2 (Quad scrn only) Alumium/Polyester foil 100% coverage 6. Screen 2 (Quad scrn only) Alluminium 7. Sheath Polyvinyl Chloride (PVC) Standard Put Up Length 305 or 500 metres Standard References IEC 61196 BS EN 50117 BS EN 50290-2 IEC 60332-1 RoHS directives 75 OHM COAX CABLES - SWEPT TO 3 GHz Physical Characteristics RG-Type over Dieletric Type of Screen Coverage Braid (%) Sheath Material Overall (kg / km) 29 RG59-FA C1025-B3 RG-59 0.81 3.71 Dual Screen 54 PVC 6.0 32.42 RG59-QS C1256-B3 RG-59 0.81 3.71 Quad Screen 54 + 46 PVC 6.73 39.4 RG6-FA C1026-B3 RG-6 1.02 4.60 Dual Screen 60 PVC 6.8 41.32 RG6-QS C1257-B3 RG-6 1.02 4.60 Quad Screen 60 + 40 PVC 7.52 49.5 RG11-FA C1027-B3 RG-11 1.63 7.11 Dual Screen 61 PVC 10.0 86.6 RG11-QS C1241-B3 RG-11 1.63 7.11 Quad Screen 60 + 40 PVC 10.3 90.6 Dual Screen = Screen 1 + Braid 1 Quad Screen = Screen 1 + Braid 1 + Screen 2 + Braid 2 Electrical and Physical Characteristics (at 20 C) RG-Type Impedance (Ω) Max. DC Resistance (Ω / km) Max. DC Screen Resistance (Ω / km) Nominal Capacitance (%) Min. Return Loss < 1000 MHz < 2000 MHz < 3000 MHz RG59-FA C1025-B3 RG-59 75 ± 3 146.5 52 53 20 18 16 RG59-QS C1256-B3 RG-59 75 ± 3 146.5 26 53 20 20 20 RG6-FA C1026-B3 RG-6 75 ± 3 92.2 30 53 20 20 20 RG6-QS C1257-B3 RG-6 75 ± 3 92.2 17 53 20 20 20 RG11-FA C1027-B3 RG-11 75 ± 3 36.5 25 53 20 20 20 RG11-QS C1241-B3 RG-11 75 ± 3 36.5 12 53 20 20 20 Nominal attenuation in db/100 m MHz 5 10 50 100 200 400 550 870 12500 1750 2150 2500 3000 RG-59 2.92 3.45 5.40 8.21 12.56 16.01 19.36 24.74 30.62 36.71 40.82 44.72 48.64 RG-6 2.2 2.48 5.15 6.6 9.56 13.12 15.45 19.69 24.25 29.26 32.88 35.88 39.83 RG-11 1.25 2.03 3.75 5.01 6.85 7.05 9.65 12.6 16.66 20.28 22.93 25.12 28.08 For more details, please see the respective detailed datasheet(s)

75 OHM COAX CABLES - SWEPT TO 4.5 GHz SECTION 5.3 HDTV and HD Video applications, sweep tested 1 to 4500 MHz Product description 1. Solid Bare Copper 2. Insulation Foamed Polyethylene (FPE) 3. Screen Bonded Aluminium/Polyester foil 100% coverage 4. Braid Tinned Copper 5. Sheath Material Polyvinyl Chloride (PVC) or Halogen-free (HFFR) Colour: Orange Standard Put Up Length 305 or 500 metres Standard References IEC 61196 BS EN 50117 BS EN 50290-2 IEC 60332-1 (PVC SHEATH) or IEC 60332-3C (HFFR cable) IEC 61034 (only HFFR cable) IEC 60754-1 & 2 (HFFR cable) RoHS directives Physical Characteristics 30 RG-Type over Dieletric Coverage Braid (%) Sheath Material Overall (kg / km) RG59-FTC C1229-B3 RG-59 0.81 3.71 95 PVC 6.0 46.72 RG59-ZA-FTC C1378-B3 RG-59 0.81 3.71 95 HFFR 6.0 48.2 RG6-FTC C1279-B3 RG-6 1.02 4.60 95 PVC 6.8 56.2 RG6-ZA-FTC C1379-B3 RG-6 1.02 4.60 95 HFFR 6.8 59 RG11-FTC C1280-B3 RG-11 1.63 7.11 95 PVC 10.0 114.5 RG11-ZA-FTC C1380-B3 RG-11 1.63 7.11 95 HFFR 10.0 117 Electrical and Physical Characteristics (at 20 C) RG-Type Impedance (Ω) Max. DC Resistance (Ω / km) Max. DC Screen Resistance (Ω / km) Nominal Capacitance (pf/m) Min. Return Loss < 1000 MHz < 2000 MHz < 3000 MHz < 4500 MHz RG59-FTC C1229-B3 RG-59 33.5 33.5 12.5 53 23 22 16 15 RG59-ZA-FTC C1378-B3 RG-59 33.5 33.5 12.5 53 23 22 16 15 RG6-FTC C1279-B3 RG-6 21.5 21.5 10.6 53 23 22 16 15 RG6-ZA-FTC C1379-B3 RG-6 21.5 21.5 10.6 53 23 22 16 15 RG11-FTC C1280-B3 RG-11 8.8 8.8 6.6 53 23 22 16 15 RG11-ZA-FTC C1380-B3 RG-11 8.8 8.8 6.6 53 23 22 16 15 Nominal attenuation in db/100 m MHz 1 5 10 50 100 300 550 750 1000 2000 3000 4500 RG-59 0.98 2.07 2.95 6.23 7.55 13.68 18.83 22.23 25.29 38.24 46.13 56.50 RG-6 0.79 1.71 2.33 4.57 6.40 11.96 15.76 18.05 21.36 3144 39.76 50.46 RG-11 0.53 1.12 1.51 2.96 4.20 7.49 10.41 12.38 14.57 21.84 27.93 35.98 For more details, please see the respective detailed datasheet(s)

SECTION 6 Application and Construction of Category Cables for Local Area Networks and Structured Wiring System 1. Application Horizontal or Building Wiring for one of the following categories of twisted pair cabling system Category Max. data rate Usual application Cat 1 1 Mbps Analogue voice Cat 2 4 Mbps Token ring of IBM Cat 3 16 Mbps Voice, 10 MbE (Ethernet) TIA/EIA 568-B Standard(s) TIA / EIA ISO / EC EN De facto, no standard issued Cat 4 20 Mbps 16 Mbps Token Ring Was only a standard briefy Cat 5 100 MHz 10/100/1000 MbE 155 Mbps ATM, Cat 5e 100 MHz 4/16 Mbps Token Ring Cat 6 Cat 6a Cat 7 Cat 7a 250 MHz 500 MHz 600 MHz 1000 MHz as Cat 5e plus 10Gb Ethernet over 55 m. as Cat 5e plus 10Gb Ethernet over 100m. As Cat 6a plus supporting 100GbE CATV (862 MHz), 40GBASE-T over 50m. 100GbE over 15 m. Replaced 5e TIA/EIA 568-C.2 CAT 7a is not recognised in TIA/EIA-569 ISO/IEC 11806, 2 nd edition IEC 61156 ISO/IEC 11801: 2002, category 7 / class F ISO/IEC 11801, amendment 1 (2008) and amendment 2 (2010) EN 50173-1 EN 50288 CATEGORY LAN CABLES 31 2. Basic Cable Constuction of the standard cables (not being patch cables) Cat 3 Cat 5e Cat 6 Cat 6a Cat 7 Cat 7a Type UTP UTP FTP UTP FTP U-UTP U-FTP S-FTP S-FTP Solid BC Solid BC Solid BC Solid BC Solid BC Solid BC Insulation Polyolefin PE PE Skin-foam-skin PE Cable core 6 to 200 pairs 4 pairs 4 Individually screened pairs Core wrapping yes no Drain wire no no yes no yes no Central drain wire Overall screen no no foil no foil Braiding Sheath PVC PVC or HFFR HFFR 3. Basic Cable Construction of the standard patch cables Cat 5e Cat 6 Type UTP FTP UTP FTP Flexible BC Insulation PE PE Cable core 4 pairs 4 pairs Core wrapping no yes no yes Drain wire no yes no yes Overall screen no foil no foil UTP = cable with unshielded twisted pairs FTP = cable with foil screened twisted pairs U-UTP = cables with no collective screen and no indiviadually screened twisted pairs U-FTP = cables with no collective screen andi individually foil screened twisted pairs S-FTP = cables with a collective braided screen and individually foil screened twisted pairs Rip cord Sheath yes PVC or HFFR All category cables have CE marking. Cat 5e and Cat 6 cables are also avaiable with UL listing

CATEGORY LAN CABLES SECTION 6 4. Basic Construction of the cables Wire = with Insulation Insulation: With good strippability, suitable for insulation displacement and coloured. The colours are not interchangeable. Pair = two twisted colour coded wires. General Characteristics Product Type Cat 3 Cat 5e Cat 6 Cat 6a Cat 7 Max. DCR conductor Ω / 100 m 9.6 9.38 9.38 7.7 7.7 Impedance Ω 100 100 100 100 100 Standard Colour scheme of cat 5e - 6-6a and 7: Pair Number Pair 1 Pair 2 Pair 3 Pair 4 a-wire Blue Orange Green Brown b-wire White with blue stripe White with orange stripe White with green stripe withe with brown stripe 32 Individually screened pair (if applicable): one pair wrapped with an Aluminium/Polyester foil. Braiding (if applicable): tinned copper wires. Ripcord: to ease removal of the sheath. Sheath: PVC or Halogen-Free (HFFR). Operating temperature range: -20 to +80 C Rated Voltage: 300 Vrms. Cable Range of B3 Italy: Category Cat 5e Cat 5e Cat 5e Cat 5e Type UTP UTP FTP FTP Sheath PVC HFFR PVC HFFR UTPLevel5-4x2x0.22 UTPLevel5-4x2x0.22ZA FTPLevel54x2x0.22 FTPLevel54x2x0.22ZA C1035-B3 C1235-B3 C1036-B3 C1236-B3 Category Cat 6 Cat 6 Cat 6 Cat 6 Type UTP UTP FTP FTP Sheath PVC HFFR PVC HFFR UTPLevel6-4x2x0.22 UTPLevel6-4x2x0.22ZA FTPLevel64x2x0.22 FTPLevel64x2x0.22ZA C1037-B3 C1237-B3 C1038-B3 C1238-B3 Category Cat 6 Cat 6 Cat 7 Cat 7 Type U-UTP U-FTP S-FTP S-FTP Sheath PVC HFFR HFFR HFFR UUTPLevel6-4x2x0.22 UFTPLevel6-4x2x0.22 SFTPLevel7 SFTPLevel7-ZA C1200-B3 C1053-B3 C1039-B3 C1201-B3 Category Cat 5e Cat 5e Cat 5e Cat 5e Cat 6 Cat 6 Cat 6 Cat 6 Type UTP-Patch UTP-Patch FTP-Patch FTP-Patch UTP-Patch UTP-Patch FTP-Patch FTP-Patch Sheath PVC HFFR PVC HFFR PVC HFFR PVC HFFR UTPLevel5-4x2x0.22- Patch UTPLevel5-4x2x0.22ZA- Patch FTPLevel54x2x0.22- Patch FTPLevel54x2x0.22ZA- Patch UTPLevel6-4x2x0.22- Patch UTPLevel6-4x2x0.22ZA- Patch FTPLevel64x2x0.22- Patch FTPLevel64x2x0.22ZA- Patch C1500-B3 C1510-B3 C1520-B3 C1530-B3 C1540-B3 C1550-B3 C1560-B3 C1570-B3 Category 2 Pairs 6 Pairs 12 Pairs 25 Pairs 50 Pairs 100 Pairs 150 Pairs 200 Pairs Cat3-PVC - Cable Code Cat3-2P Cat3-6P Cat3-12P Cat3-25P Cat3-50P Cat3-100P Cat3-150P Cat3-200P Cat3-PVC - C1031-B3 C1226-B3 C1267-B3 C1032-B3 C1033-B3 C1034-B3 C1268-B3 C1269-B3 Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s). Please note that technical specifications are subject to change without notice.

SECTION 6.1 Cat 5e and 6 UTP and FTP cables Physical Characteristics of Cat 5e Cables Type Sheath Overall UTPLevel5-4x2x0.22 C1035-B3 UTP PVC 5.0 30 UTPLevel5-4x2x0.22ZA C1235-B3 UTP HFFR 5.0 29 FTPLevel54x2x0.22 C1036-B3 FTP PVC 6.3 42 FTPLevel54x2x0.22ZA C1236-B3 FTP HFFR 6.3 42 Main Transmission Characteristics of Cat 5e cables Frenquency (MHz) Min.Return Loss (db/100m) Maximum Attenuation (db/100m) Minimum NEXT Maximum Time Delay (ns/100m) Maximum PSNEXT Minimum ELFEXT Minimum PSEL- FEXT CATEGORY 5e AND 6 LAN CABLES 1 20.0 2.0 65.3 570.00 62.3 64.0 61.0 4 23.0 4.1 56.3 552.00 53.3 52.0 49.0 8 24.5 5.8 51.8 546.73 48.8 45.9 42.9 10 25.0 6.5 50.3 545.38 47.3 44.0 41.0 16 25.0 8.2 47.2 543.00 44.4 39.9 36.9 20 25.0 9.3 45.8 542.05 42.8 38.0 35.0 33 25 24.3 10.4 44.3 541.20 41.3 35.8 33.0 31.25 23.6 11.7 42.9 540.44 39.9 34.1 31.1 62.5 21.5 17.0 38.4 538.55 35.4 28.1 25.1 100 20.1 22.0 35.3 537.60 32.3 24.0 21.0 Physical Characteristics of Cat 6 Cables Type Sheath Overall UTPLevel6-4x2x0.22 C1037-B3 UTP PVC 6.2 42 UTPLevel6-4x2x0.22ZA C1237-B3 UTP HFFR 6.2 42 FTPLevel64x2x0.22 C1038-B3 FTP PVC 7.4 56 FTPLevel64x2x0.22ZA C1238-B3 FTP HFFR 7.4 54.1 Main Transmission Characteristics of Cat 6 cables Frequency (MHz) Return Loss (db/100m) Maximum Attenuation (db/100) Minimum NEXT Maximum Time Delay (ns/100m) Minimum PSNEXT Minimum ELFEXT Minimum PSEL- FEXT 1 20.0 2.0 74.3 570.00 72.3 67.8 64.8 4 23.0 3.8 65.3 552.00 63.3 55.8 52.8 8 24.5 5.3 60.8 546.73 58.8 49.7 46.7 10 25.0 6.0 59.3 545.38 57.3 47.8 44.8 16 25.0 7.6 56.2 543.00 54.2 43.7 40.7 20 25.0 8.5 54.8 542.05 52.8 41.8 38.8 25 24.3 9.5 53.3 541.20 51.3 39.8 36.8 31.25 23.6 10.7 51.9 540.44 49.9 37.9 34.9 62.5 21.5 15.4 47.4 538.55 45.4 31.9 28.9 100 20.1 19.8 44.3 537.80 42.3 27.8 24.8 200 18.0 29.0 39.8 536.54 37.8 21.8 18.8 250 17.3 32.8 38.3 536.27 36.3 19.8 16.8 For more details, please see the respective detailed datasheet(s)

CATEGORY 6.7 AND 7a CABLES SECTION 6.2 CAT 6a U-FTP and Cat 7/7a S-FTP cables Physical Characteristics of Cat 6a Cables Type Sheath Overall UUTPLevel6-4x2x0.22 C1200-B3 U-UTP PVC 8.3 61.2 UFTPLevel6-4x2x0.22 C1053-B3 U-FTP HFFR 7.2 49.9 Main Transmission Characteristics of Cat 6a U-FTP cables Frequency (MHz) Return Loss (db/100m) Attenuation (db/100m) NEXT PSNEXT ELFEXT Impedance (Ohm) 1 20.0 3.7 74.3 72.3 55.9 100 ± 15 10 25.0 5.8 59.3 57.3 47.8 100 ± 15 31.25 23.6 10.4 51.9 49.9 37.9 100 ± 15 100 20.1 19.0 44.3 42.3 27.8 100 ± 15 300 17.3 34.2 37.1 35.1 18.1 100 ± 25 34 500 17.3 45.2 33.8 31.8 14.0 100 ± 15 Physical Characteristics of Cat 7 Cables Type Sheath Overall SFTPLevel7 C1039-B3 S-FTP HFFR 7.8 67.5 Main transmission Characteristics of Cat 7 S-FTP cables Frequency (MHz) Return Loss (db/100m) Attenuation (db/100m) NEXT PSNEXT ELFEXT Impedance (Ohm) 1 20.0 2.5 78 75 78.0 100 ± 15 10 25.0 6.5 78 75 56.5 100 ± 15 20 25.0 8.9 78 75 56.5 100 ± 15 62.5 21.5 14.9 75.5 72.5 56.8 100 ± 15 300 14.5 35.2 65.2 62.2 25.0 100 ± 25 600 12.5 50.1 60.7 57.7 16.0 100 ± 25 Physiscal Characteristics of Cat 7a Cables Type Sheath Overall SFTPLevel7-ZA C1201-B3 S-FTP HFFR 8.5 71.1 Main Transmission Characteristics of Cat 7a S-FTP Cables Frequency (MHz) Return Loss (db/100m) Attenuation (db/100m) NEXT PSNEXT ELFEXT Impedance (Ohm) 4 23.0 4.0 80.0 77.0 78.0 100 ± 15 10 25.0 5.8 80.0 77.0 74.3 100 ± 15 20 25.0 8.2 80.0 77.0 71.0 100 ± 15 62.5 21.5 14.6 80.0 77.0 60.6 100 ± 15 300 17.3 32.7 71.2 68.2 38.6 100 ± 25 600 17.3 47.1 66.7 63.7 19.6 100 ± 25 900 17.3 54.9 64.9 61.9 9.93 100 ± 25 1000 16.0 61.9 63.4 60.4 1.47 100 ± 25 For more details, please see the respective detailed datasheet(s)

SECTION 6.3 Cat 5e and Cat 6 UTP and FTP PATCH Cables Physical Characteristics of Cat 6 Patch Cables Type Sheath Overall UTPLevel5-4x2x0.22-Patch C1500-B3 UTP PVC 5.2 30.7 UTPLevel5-4x2x0.22ZA-Patch C1510-B3 UTP HFFR 5.2 31.4 FTPLevel54x2x0.22-Patch C1520-B3 FTP PVC 5.1 31.2 FTPLevel54x2x0.22ZA-Patch C1530-B3 FTP HFFR 5.1 31.1 Physical Characteristics of Cat 5e Patch cables Cat 6 - Patch UTP / FTP UTP FTP UTP / FTP UTP / FTP UTP / FTP UTP / FTP Frequency (MHz) Return Loss (db/100m) Maximum Attenuation (db/100m) Maximum Attenuation (db/100m) Maximum NEXT Maximum PSNEXT Maximum ELFEXT Minimum PSELFNEXT CATEGORY 5e AND 6 PATCH LAN CABLES 1 20.0 2.4 3.1 65.3 62.3 63.8 60.8 4 23.0 4.9 6.1 56.3 53.3 51.8 48.8 8 24.5 6.9 8.6 51.8 48.8 45.7 42.7 10 25.0 7.8 9.7 50.3 47.3 43.8 40.8 16 25.0 9.9 12.4 47.2 44.2 39.7 36.7 20 25.0 11.1 13.9 45.8 42.8 37.8 34.8 35 25 24.2 12.5 15.6 44.3 41.3 35.8 32.8 31.25 23.3 14.1 17.6 42.9 39.9 33.9 30.9 62.5 20.7 20.4 25.5 38.4 35.4 27.9 24.9 100 19.0 26.4 33.0 35.3 32.3 23.8 20.8 Physical Characteristics of Cat 6 Patch Cables Type Sheath Overall UTPLevel6-4x2x0.22-Patch C1540-B3 UTP PVC 5.9 31.6 UTPLevel6-4x2x0.22ZA-Patch C1550-B3 UTP HFFR 5.9 32.4 FTPLevel64x2x0.22-Patch C1560-B3 FTP PVC 6.2 34.6 FTPLevel64x2x0.22ZA-Patch C1570-B3 FTP HFFR 6.2 35.8 Main Transmission Characteristics of Cat 6 Patch cables Cat 6 - Patch UTP / FTP UTP FTP UTP / FTP UTP / FTP UTP / FTP UTP / FTP Frequency (MHz) Return Loss (db/100m) Maximum Attenuation (db/100m) Maximum Attenuation (db/100m) Maximum NEXT Maximum PSNEXT Maximum ELFEXT Minimum PSELFNEXT 1 20.0 2.4 3.1 74.3 72.3 67.8 64.8 4 23.0 4.6 6.1 65.3 63.3 56.0 53.0 10 25.0 7.2 8.6 59.3 57.3 48.0 45.0 16 25.0 9.1 12.4 56.2 54.2 43.9 40.9 20 25.0 10.2 13.9 54.8 52.8 42.0 39.0 31.25 23.3 12.9 17.6 51.9 49.9 38.1 35.1 62.5 20.7 18.6 25.5 47.4 45.4 32.1 29.1 100 19.0 23.9 33.0 44.3 42.3 28.0 25.0 200 16.4 35.0 48.6 39.8 37.8 22.0 19.0 250 15.5 39.4 55.3 38.3 36.3 20.0 17.0 For monre details, please see the respective detailed datasheet(s)

CATEGORY 3 CABLES SECTION 6.4 Cat 3 multi pair cables Physical Characteristics of Cat 3 cables B3 Number No. of pairs Sheath Nom.diameter over insulation Overall Cat3-2P C1031-B3 2 0.5 0.9 3.6 16 Cat3-6P C1266-B3 6 0.5 0.9 5.5 39 Cat3-12P C1267-B3 12 0.5 0.9 7.4 73 Cat3-25P C1032-B3 25 0.5 0.9 11.8 154 Cat3-50P C1033-B3 50 0.5 0.9 15.5 280 Cat3-100P C1034-B3 100 0.5 0.9 21.6 530 Cat3-150P C1268-B3 150 0.5 0.9 26.8 800 Cat3-200P C1269-B3 200 0.5 0.9 29.4 1040 Electrical Characteristics of Cat 3 Cables at 20 C 36 Frequency (MHz) Max. Attenuation (db/100m) Max. NEXT Min. Return Loss Impedance (Ohm) 1 2.6 41.3 12.0 100 ± 15 4 5.6 32.3 12.0 100 ± 15 8 8.5 27.8 12.0 100 ± 15 10 9.7 26.3 12.0 100 ± 15 16 13.1 23.3 10.0 100 ± 15 Cable Make-Up of Cat 3 cables B3 Number Cat3-2P C1031 Cat3-6P C1266 Cat3-12P C1267 Cat3-25P C1032 Cat3-50P C1033 Cat3-100P C1034 Cat3-150P C1268 Cat3-200P C1269 No of pairs 2 6 12 25 50 100 150 200 Number of pairs per unit - - - 25 10 25 25 25 Number of units in the center - - - 1 5 4 1 1 Number of units in the 1st layer - - - - - - 5 7 Pair Colour Code of Cat 3 cables Pair No. Pair Colours (a leg / b leg) Pair No. Pair Colours in unit of 12 or 25 pairs Pair No. Pair Colours in Unit of 25 pairs 1 White / Blue 11 Black / Blue 21 Purple / Blue 2 White / Orange 12 Black / Orange 22 Purple / Orange 3 White / Green 13 Black / Green 23 Purple / Green 4 White / Brown 14 Black / Brown 24 Purple / Brown 5 White / Grey 15 Black / Grey 25 Purple / Grey 6 Red / Blue 16 Yellow / Blue - 7 Red / Orange 17 Yellow / Orange - 8 Red / Green 18 Yellow / Green - 9 Red / Brown 19 Yellow / Brown - 10 Red / Grey 20 Yellow / Grey - For more details, please see the respective detailed datasheet(s)

SECTION 7 Def. Stan. 61-12 s 4 & 5 1. Application Originally developed for military use, these flexible multi-conductor cables are now widely used within the industry. They are designed for high density wiring between and within instruments and electronic equipment and/or components and are especially used in process control systems, computers, data processors, sound systems and in military equipment. 2. Main Standard Wire = with Insulation. : flexible = stranded tinned copper wires. Size mm 2 0.055 0.22 0.5 DEF STAN CABLES Configuration n x mm 7 x 0.1 7 x 0.2 16 x 0.20 Max. DC Resistance Ω / mm 345 86.2 37.7 Max. recommended current Amps 0.25 1 2.5 Rated Voltage Vrms 250 440 440 Insulation: PVC (Polyvinyl Chloride). Good strippability and coloured insulation. The colours are not interchangeable. 37 Cable core: two or more wires, stranded. Core No. Colour Core No. Colour Core No. Colour Core No. Colour 1 RED 11 TURQUOISE 21 BLUE / Black 31 WHITE / Brown 2 BLUE 12 GREY 22 Orange / Blue 32 BROWN / Black 3 GREEN 13 RED / Blue 23 GREEN / Blue 33 GREY / Brown 4 YELLOW 14 GREEN / Red 24 GREY / Blue 34 YELLOW / Violet 5 WHITE 15 YELLOW / Red 25 YELLOW / Green 35 VIOLET / Black 6 BLACK 16 WHITE / Red 26 WHITE / Green 36 WHITE / Violet 7 BROWN 17 RED / Black 27 GREEN / Black 8 VIOLET 18 RED / Brown 28 ORANGE / Green 50 Special scheme, available on request 9 ORANGE 19 YELLOW / Blue 29 GREY / Green - - 10 PINK 20 WHITE / Blue 30 YELLOW / Brown - - Drain wire (only in combination with a screen): twisted (= flexible) tinned copper wires. Screen (if applicable): Braiding of tinned copper wires. Coverage 91%. Sheath: black PVC Flame Retardancy: IEC 60332-1 (Vertical Wire test). Operating temperature range: -20 to +80 C. Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s) Please note that technical specifications are subject to change without notice

DEF STAN CABLES SECTION 7 Product Description 1. Stranded Tinned Copper 2. Insulation PVC 3. Screen Two or more wires stranded 7x0.1 mm = 0.055 mm 2 4. Screen (if required) Tinned Copper 91% Coverage 5. Ripcord 6. Sheath Material Flame-Retardant Polyvinyl Chloride (PVC) Standard colour: Black Standard Put Up Lenght 305 metres Standard References Def.stan. 61-12 s 4 & 5 IEC 60332-1 RoHS directives No. of wires Screen Screen 2 STS0201HEAAX-T C1164-B3 Yes 3.2 SSS0201HEAAX-T C1360-B3 No 2.3 3 STS0301HEAAX-T C1165-B3 Yes 3.6 SSS0301HEAAX-T C1361-B3 No 2.4 38 4 6 9 - - - - STS0601HEAAX-T C1166V Yes 4.2 - - - - SSS0401HEAAX-T C1362-B3 No 2.6 SSS0601HEAAX-T C1144-B3 No 3.1 SSS0901HEAAX-T C1145-B3 No 3.7 15 - - - - SSS1501HEAAX-T C1146-B3 No 4.2 25 STS2501HEAAX-T C1168-B3 Yes 6.3 SSS2501HEAAX-T C1147-B3 No 5.5 36 STS3601HEAAX-T C1169-B3 Yes 6.9 SSS3601HEAAX-T C1148-B3 No 6.1 50 STS5001HEAAX-T C1365-B3 Yes 8.0 SSS5001HEAAX-T C1364-B3 No 7.2 7x0.2 mm = 0.22 mm 2 No. of wires Screen Screen 2 3 4 6 8 12 20 36 - - - - - - - - STS0422HEAAX-T C1471-B3 Yes 4.4 STS0622HEAAX-T C1472-B3 Yes 5.6 STS0822HEAAX-T C1473-B3 Yes 6.1 STS1222HEAAX-T C1474-B3 Yes 6.9 STS2022HEAAX-T C1475-B3 Yes 8.6 STS3622HEAAX-T C1476-B3 Yes 10.8 SSS0222HEAAX-T C1366-B3 No 3.4 SSS0322HEAAX-T C1367-B3 No 3.6 SSS0422HEAAX-T C1368-B3 No 3.9 SSS0622HEAAX-T C1169-B3 No 4.6 SSS0822HEAAX-T C1154-B3 No 5.6 SSS1222HEAAX-T C1155-B3 No 6.1 SSS2022HEAAX-T C1156-B3 No 7.8 SSS3622HEAAX-T C1157-B3 No 9.8 16x0.2 mm = 0.22 mm 2 No. of wires Screen Screen 2 3 4 6 12 18 STS0250HEAAX-T - - - STS0350HEAAX-T - - - STS0450HEAAX-T C1177-B3 Yes 7.3 STS0650HEAAX-T C1178-B3 Yes 8.3 STS1250HEAAX-T C1375-B3 Yes 10.5 STS1850HEAAX-T C1180-B3 Yes 12.0 SSS0250HEAAX-T C1158-B3 No 5.5 SSS0350HEAAX-T C1370-B3 No 5.8 SSS0450HEAAX-T C1371-B3 No 6.3 SSS0650HEAAX-T C1372-B3 No 7.3 SSS1250HEAAX-T C1373-B3 No 9.5 SSS1850HEAAX-T C1374-B3 No 11.0

SECTION 8 Application and Construction 1. Application These cables are generally used to transmit analogue or digital signals in industrial process plants where chemical and mechanical protections are needed e.g. chemical and petrochemical industries. The unarmoured versions (Type 1) are generally used for indoor installation. 2. Main Standard BS5308/PAS5308 2 Type 1 & 2. 3. Basic Construction of the cables Wire = with Insulation. : flexible = stranded tinned copper wires. Pair: two twisted wires. INSTRUMENTATION CABLES Size mm 2 0.5 0.75 1.5 Configuration n x mm 16 x 0.2 24 x 0.2 7 x 0.53 Max. DC Resistance at 20 C Ω/km 39.7 26.5 12.3 Max. conductor temperature C 65 65 65 Min. operating temperature C -20-20 -20 39 Max. recommended current Amps 6 8 12 Max. mutual capacitance at 1 khz pf/m 250 250 250 Max. L/R ratio μh/ω 25 25 40 Rated Voltage Vrms 300/500 300/500 300/500 Insulation: PVC (Polyvinyl Chloride) in accordance with BS 7655. Good strippability and coloured insulation. The colours are readily identifi able and are not interchangeable. Cable core: two or more pairs, stranded Colour scheme: Pair No. 1 2 3 4 5 6 7 8 9 10 a-wire White White White White White Red Red Red Red Red b-wire Blue Orange Green Brown Grey Blue Orange Green Brown Grey Pair No. 11 12 13 14 15 16 17 18 19 20 a-wire Black Black Black Black Black Yellow Yellow Yellow Yellow Yellow b-wire Blue Orange Green Brown Grey Blue Orange Green Brown Grey Drain wire (only in combination with an individual or collective screen): stranded tinned copper wires. Individual Screen (if applicable): Aluminium/Polyester (Alpet) tape. Coverage 115%. Collective Screen (if applicable): Aluminium/Polyester (Alpet) tape. Coverage 115%. Bedding (if applicable): Flame Retardant PVC. Armour (if applicable): galvanised steel wires. Sheath: Flame Retardant PVC. Flame Retardancy: IEC 60332-1 (Vertical Wire test). Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s). Please note that technical specifications are subject to change without notice.

INSTRUMENTATION CABLES SECTION 8 BS5308/PAS5308-2 - Type 1 - Collectively Screeend Cables 0.5 mm 2 (16 x 0.2 mm) No. of wires 1 2 5 10 20 0.75 mm 2 (24 x 0.2 mm) Armour MAS0150HEAAX-OIL C1081-B3 No 7.0 50 MAS0250HEAAX-OIL C1082-B3 No 7.9 72 MAS0550HEAAX-OIL C1083-B3 No 13.1 170 MAS1050HEAAX-OIL C1084-B3 No 17.2 290 MAS2050HEAAX-OIL C1085-B3 No 22.3 500 Armour MAS0150AEAAX-OIL C1096-B3 Yes 11.4 240 MAS0250AEAAX-OIL C1097-B3 Yes 12.3 290 MAS0550AEAAX-OIL C1098-B3 Yes 17.9 510 MAS1050AEAAX-OIL C1099-B3 Yes 22.9 880 MAS2050AEAAX-OIL C1100-B3 Yes 29.1 1500 No. of wires Armour Armour 1 MAS0175HEAAX-OIL C1086-B3 No 7.3 60 MAS0175AEAAX-OIL C1101-B3 Yes 11.7 270 2 MAS0275HEAAX-OIL C1087-B3 No 8.3 100 MAS0275AEAAX-OIL C1102-B3 Yes 12.9 310 40 5 10 20 MAS0575HEAAX-OIL C1088-B3 No 14.3 210 MAS1075HEAAX-OIL C1089-B3 No 18.7 350 MAS2075HEAAX-OIL C1090-B3 No 24.5 750 MAS0575AEAAX-OIL C1103-B3 Yes 19.8 710 MAS1075AEAAX-OIL C1104-B3 Yes 25.3 1200 MAS2075AEAAX-OIL C1105-B3 Yes 31.3 1700 1.5 mm 2 (7 x 0.53 mm) No. of wires Armour Armour 1 2 5 10 20 MAS0115HEAAX-OIL C1091-B3 No 8.3 90 MAS0215HEAAX-OIL C1092-B3 No 9.7 140 MAS0515HEAAX-OIL C1093-B3 No 16.4 330 MAS1015HEAAX-OIL C1094-B3 No 20.6 580 MAS2015HEAAX-OIL C1095-B3 No 28.5 1100 MAS0115AEAAX-OIL C1106-B3 Yes 12.9 300 MAS0215AEAAX-OIL C1107-B3 Yes 14.3 390 MAS0515AEAAX-OIL C1108-B3 Yes 22.1 870 MAS1015AEAAX-OIL C1109-B3 Yes 28.4 1500 MAS2015AEAAX-OIL C1110-B3 Yes 35.7 2400 For more details, please see the respective detailed datasheet(s)

SECTION 8 BS5308/PAS5308-2 - Type 1 - Individually & Collectively Screened Cables 0.5 mm 2 (16 x 0.2 mm) No. of wires 2 5 10 20 Armour 0.75 mm 2 (24 x 0.2 mm) MAC0250HEAAX-OIL C1111-B3 No 12.0 100 MAC0550HEAAX-OIL C1112-B3 No 15.2 250 MAC1050HEAAX-OIL C1113-B3 No 21.1 480 MAC2050HEAAX-OIL C1114-B3 No 27.3 780 Armour MAC0250AEAAX-OIL C1123-B3 Yes 16.8 450 MAC0550AEAAX-OIL C1124-B3 Yes 20.9 750 MAC1050AEAAX-OIL C1125-B3 Yes 27.9 1300 MAC2050AEAAX-OIL C1126-B3 Yes 34.4 1900 No. of wires Armour Armour 2 MAC0275HEAAX-OIL C1115-B3 No 12.8 190 MAC0275AEAAX-OIL C1127-B3 Yes 17.6 490 5 MAC0575HEAAX-OIL C1116-B3 No 16.3 270 MAC0575AEAAX-OIL C1128-B3 Yes 22.0 801 10 20 MAC1075HEAAX-OIL C1117-B3 No 22.7 550 MAC2075HEAAX-OIL C1118-B3 No 29.8 960 MAC1075AEAAX-OIL C1129-B3 Yes 29.5 1800 MAC2075AEAAX-OIL C1130-B3 Yes 37.8 2200 41 1.5 mm 2 (7 x 0.53 mm) No. of wires Armour Armour 2 5 10 20 MAC0215HEAAX-OIL C1119-B3 No 14.7 250 MAC0515HEAAX-OIL C1120-B3 No 18.8 460 MAC1015HEAAX-OIL C1121-B3 No 26.5 760 MAC2015HEAAX-OIL C1122-B3 No 34.4 1350 MAC0215AEAAX-OIL C1131-B3 Yes 20.4 660 MAC0515AEAAX-OIL C1132-B3 Yes 25.4 1000 MAC1015AEAAX-OIL C1133-B3 Yes 33.5 1700 MAC2015AEAAX-OIL C1134-B3 Yes 42.6 2800 For more details, please see the respective detailed datasheet(s) INSTRUMENTATION CABLES

CONTROL CABLES SECTION 9 Application and Construction 1. Application These cables are commonly used as interconnecting cables to control, measure and regulate processor aided production within industry and also as flexible power control cables suitable for robotic and automated equipment. 2. Main Standard VDE 0250 3. Basic Construction of the cables Wire = with Insulation. : flexible = stranded tinned copper wires. Size mm 2 0.75 1.0 1.5 2.5 4 6 material - bare copper Configuration n x mm 24x0.2 32x0.2 30x0.24 50x0.24 56x0.29 84x0.29 42 Max. DC Resistance at 20 C Ω/km 27 220.2 14 8.4 4.95 3.3 n - number of ends in conductor Insulation: Flame Retardant PVC (Polyvinyl Chloride). Insulation Resistance > 500 MΩ/km. Size mm 2 0.75 1.0 1.5 2.5 4 6 Radial thickness of insulation mm 0.5 0.5 0.4 0.5 0.8 0.7 Cable core: three or more wires stranded. In case of 5 wires with a central fi ller. Colour scheme: Green/yellow - black with printed numbers. Collective Screen (CY series): braiding of tinned copper wires with a coverage of 70%. Bedding (SY series): Flame Retardant PVC. Armour (SY series): galvanised steel wires. Sheath: Flame Retardant PVC. Flame Retardancy: IEC 60332-1 (Vertical Wire test). Operating temperature range: -20 to +70 C. Rated Voltage: 300 V. Cable Types: YY series: three or more stranded cores, surrounded a PVC sheath. CY series: as YY series plus a collective screen between cable core and PVC sheath. SY series: as YY series plus a Steel Wire Armouring between cable core and transparent PVC sheath. Non-standard cable constructions, colours, details and/or additional information are available on request. For more details, please see the respective detailed datasheet(s).please note that technical specifi cations are subject to change without notice.

SECTION 9 YY Series: Cable core of stranded cores surrounded a PVC sheath No. of wires 3 4 12 18 No. of wires 3 4 CSA (mm 2 ) Configuration (n x mm) SSS0375HBAAC C1631-B3 0.75 24 x 0.2 5.6 SSS0475HBAAC C1635-B3 0.75 24 x 0.2 6.6 SSS1275HBAAC C1645-B3 0.75 24 x 0.2 10.4 SSS1875HBAAC C1648-B3 0.75 24 x 0.2 12.4 CSA (mm 2 ) Configuration (n x mm) SSS0315HBAAC C1633-B3 1.5 30 x 0.24 6.5 SSS0415HBAAC C1637-B3 1.5 30 x 0.24 7.6 CSA (mm 2 ) Configuration (n x mm) SSS0310HBAAC C1632-B3 1.0 32 x 0.2 3.2 SSS0410HBAAC C1636-B3 1.0 32 x 0.2 7.1 - - - - - - - - - - CSA (mm 2 ) Configuration (n x mm) SSS0325HBAAC C1634-B3 2.5 50 x 0.24 6.5 SSS0425HBAAC C1638-B3 2.5 50 x 0.24 9.1 CONTROL CABLES 5 7 8 12 18 SSS0515HBAAC C1639-B3 1.5 30 x 0.24 8.4 SSS0715HBAAC C1641-B3 1.5 30 x 0.24 9.5 SSS0815HBAAC C1643-B3 1.5 30 x 0.24 10.4 SSS1215HBAAC C1646-B3 1.5 30 x 0.24 12.4 SSS1815HBAAC C1649-B3 1.5 30 x 0.24 14.5 SSS0525HBAAC C1640-B3 2.5 50 x 0.24 10.3 SSS0725HBAAC C1642-B3 2.5 50 x 0.24 11.8 SSS0825HBAAC C1644-B3 2.5 50 x 0.24 12.6 SSS1225HBAAC C1647-B3 2.5 50 x 0.24 14.9 SSS1825HBAAC C1650-B3 2.5 50 x 0.24 14.5 CY Series: Cable core of stranded cores surrounded a braiding of tinned copper wire plus a PVC sheath 43 No. of wires CSA (mm 2 ) Configuration (n x mm) CSA (mm 2 ) Configuration (n x mm) 3 4 STS0375HBAAC C1620-B3 0.75 24 x 0.2 6.0 STS0475HBAAC C1624-B3 0.75 24 x 0.2 6.7 STS0310HBAAC C1621-B3 1.0 32 x 0.2 6.4 STS0410HBAAC C1625-B3 1.0 32 x 0.2 7.0 No. of wires CSA (mm 2 ) Configuration (n x mm) CSA (mm 2 ) Configuration (n x mm) 3 4 5 STS0315HBAAC C1622-B3 1.5 30 x 0.24 6.8 STS0415HBAAC C1626-B3 1.5 30 x 0.24 7.6 STS0515HBAAC C1628-B3 1.5 30 x 0.24 8.2 STS0325HBAAC C1623-B3 2.5 50 x 0.24 8.0 STS0425HBAAC C1627-B3 2.5 50 x 0.24 9.0 STS0525HBAAC C1629-B3 2.5 50 x 0.24 9.8 SY Series: Cable core of stranded cores surrounded bedding. Steel Wire Armouring plus a PVC sheath No. of wires CSA (mm 2 ) Configuration (n x mm) CSA (mm 2 ) Configuration (n x mm) 3 STS0375ABAAC C1655-B3 0.75 24 x 0.2 7.8 STS0310ABAAC C1658-B3 2.5 50 x 0.24-4 - - - - - STS0410ABAAC C1662-B3 2.5 50 x 0.24 - No. of wires 2 CSA (mm 2 ) Configuration (n x mm) STS0210ABAAC C1651-B3 1.0 32 x 0.2 8.2 CSA (mm 2 ) Configuration (n x mm) STS0215ABAAC C1652-B3 1.5 30 x 0.24 9.4 3 STS0310ABAAC C1656-B3 1.0 32 x 0.2 8.2 STS0315ABAAC C1657-B3 1.5 30 x 0.24 9.4 4 STS0410ABAAC C1660-B3 1.0 32 x 0.2 8.2 STS0415ABAAC C1661-B3 1.5 30 x 0.24 9.4 5 STS0510ABAAC C1665-B3 1.0 32 x 0.2 10.6 STS0515ABAAC C1666-B3 1.5 30 x 0.24 11.2 6 - - - - - STS0615ABAAC C1668-B3 1.5 30 x 0.24 12.3 7 STS0710ABAAC C1669-B3 1.0 32 x 0.2 11.7 STS0715ABAAC C1670-B3 1.5 30 x 0.24 12.4 12 STS1210ABAAC C1671-B3 1.0 32 x 0.2 13.8 STS1215ABAAC C1672-B3 1.5 30 x 0.24 14.3 18 STS1810ABAAC C1673-B3 1.0 32 x 0.2 15.8 STS1815ABAAC C1674-B3 1.5 30 x 0.24 16.8 25 STS2510ABAAC C1675-B3 1.0 32 x 0.2 19.7 - - - - - No. of wires CSA (mm 2 ) Configuration (n x mm) CSA (mm 2 ) Configuration (n x mm) 3 4 STS0240ABAAC C1659-B3 4.0 56 x 0.29 13.4 STS0440ABAAC C1663-B3 4.0 56 x 0.29 13.4 - - - - - STS0460ABAAC C1664-B3 6.0 84 x 0.29 16.0 For more details, please see the respective detailed datasheet(s)

TECHNICAL GENERAL TECHNICAL INFORMATION Pairs: all pairs consist of two twisted wires with a lay-length < 40 D. Cable Cores: all cable cores consist of stranded wires or pairs Foil screens for multi-core and multi-pair cables mostly consist of an aluminium foil laminated to polyester, broadly known as Alpet. These foils are helically (as a spiral) applied with sufficient overlap to guarantee 115% or more coverage. For the flexibility of a cable a helically applied foil is to be preferred as a longitudinally applied foil is more difficult to bend. A drain wire, contacting the aluminium side of the foil, is used for the termination of the screen and also to ground electrostatic discharges. In the case of coaxial cable, where the screen may be a foil, this foil will be applied longitudinally and will also be bonded to the dielectric. Braided screens consist of 16 or 24 groups of strands. One set of 8 or 12 strands is woven clockwise and the other set of 8 or 12 strands anticlockwise. Strands can consist of tinned or bare copper or aluminium wires. Braided screens provide good screening efficiency and flexibility. Higher coverage provides better screening. 44 Sheaths: grey PVC, purple HFFR or black for PE, all in accordance with BS EN 50290-2. Sheath PVC PVC HFFR PE Physical properties BS EN 50290-2-22 UL444 BS EN 50290-2-27 BS EN 50290-2-24 Retardancy Flame Fire Fire Not applicable Retardancy acc. to IEC 60332-1 UL1666 IEC 60332-3C Not applicable Low Smoke Not applicable Not applicable IEC 61034 Not applicable Halogen-Free (non acid, non toxic) Not applicable Not applicable IEC 60754 Not applicable RoHS complicant YES YES YES YES Installation** INDOOR INDOOR INDOOR OUTDOOR ** on request cables with a sheath for indoor and outdoor i.e. universal use are available. RoHS limiits for hazardous substances Substance Max. Concentration Lead (Pb) 0.03% Mercury (Hg) 0.10% Cadmium (Cd) 0.01% Chromium 6 0.1% PBB 0.1% Unless marked otherwise, all B3 Italy cables do not contain restricted or hazardous substances and are compliant with the European Regulations or Directives for RoHS (Restriction of Hazardous Substances), REACH (Regulation Registration, Evaluation, Authorisation and Restriction of Chemical substances), WEEE (Waste Electrical and Electronic Equipment ), ELV (End of Life Vehicles) and BFR (Brominated Flame Retardants). PBDE 0.1 RS Protocol RS-232 RS-422 RS-485 Differential no yes yes Max. number of drivers Max. number of receivers 1 1 1 10 1 32 Modes of operation full duplex half duplex half duplex Network topology pint-to-point multidrop multidrop Max. distance acc. to standard 15 m 1200 m 1200 m Max. speed at 12 m. Max. speed at 1200 m. 20 kbs 1 kbs 10 Mbs 100 kbs 35 Mbs 100 kbs Cables used 6 to 25 conductors. No impedance specified mainly 24AWG conductors. Two pairs or more. 100 ohm mainly 24AWG conductors. One pair or more. 120 ohm RAMCRO part numbers see section 1.3 section 1.2 section 1.1

COMPARISON BETWEEN EUROPEAN & UNITED STATES CABLE DESIGN BASICS Europe Focus on SAFETY = SAVING LIVES Focus Focus on REDUCING INSURANCE CLAIMS Low Voltage Directive Directives National Electrical Code 220 Volt, 50 Hz Power supply system 120 Volt, 60 Hz More radial thickness of insulation Cable basics More copper in conductors IEC-EN and National Standards Standards UL standards Cable specs. in mm, N, etc. Units Cable specs. in inches, lbs, etc. 70 C (is equal to 80 C in USA) Temperature Ratings 80 C (Is equal to 70 C in Europe) 300 / 500 Vrms 300 Vrms Voltage Ratings 450 / 750 Vrms 600 Vrms IEC 60332-1 IEC 60332-3-24 (former 3C) Retardancy levels USA UL1581 VW-1 RoHS compliant Environmental requirements A number of states banned Hg and PBDE CE Marking The CE marking certifi es that a product has met EU consumer safety, health or environmental requirements. By affi xing the CE marking to a product, the manufacturer on his sole responsibility declares that it meets EU safety, health and environmental requirements or, if stipulated in the directive(s), it had to be examined a notifi ed conformity assessment body. Quality assurance UL1685 UL Approval / Listing UL does not approve products. Rather it evaluates products for compliance to specifi c requirements, and permits acceptable products to carry a UL certifi cation mark, as long as they remain compliant with the standards. Products under the UL listing service are said to be UL Listed, identifi ed the distinctive UL mark. TECHNICAL CONVERSION Europe USA 45 1 mm = 0.03937 inches 1 inch = 25,4 mm 1 m = 3.2808 feet (305 m = 1000 feet) 1 m = 1.0936 feet 1 km = 0.6214 miles 1 kg/km = 0.6719 lbs/1000 ft 1 ohm/km = 0.3048 ohm/1000 ft 1 N = 0.2248 lbs force -40 C = -40 F -30 C = -22 F 0 C = 32 F 60 C = 90 F 75 C = 167 F 90 C = 194 F 1 feet = 0.3048 m 1 yard = 0.9144m 1 mile = 1.6093 km 1 lbs/1000 ft = 1.488 kg/km 1 ohm/1000 ft = 3.2808 ohm/km 1 lbs force = 0.2248 N -40 F = -40 C -22 F = -30 C 32 F = 0 C 90 F = -60 C 167 F = -75 C 194 F = -90 C Area Conversion From To Multiply To Multiply To Multiply Circular mils Square inches 0.0000007854 Square Mils 0.7854 mm 2 0.0005067 Square inches Circular mils 1,273.240 Square Mils 1,000,000.00 mm 2 645.16 mm 2 Square inches 0.00155 Square Mils 1550.01 Circular mils 1,973.53 Square feet Square inches 0.0929 Common Occurring Conversion AWG 24 22-20 19/18 18 18/17 16 15/16 14 14/13 12-11 Cir. mils 404 640 987 1029 1481 1620 1974 2580 2961 4110 4935 6530 7896 8230 mm 2 0.205 0.324 0.5 0.521 0.75 0.821 1.0 1.371 1.5 2.082 2.5 3.309 4.0 4.170 Force, Mass and Conversion From to Multiply From to Multiply Pounds Kilograms 0.4535 Pound per 1000 ft Kilogram per kilometre 1.488 Pound-force Newton 4.4482 Kilograms Pounds 2.205 Kilogram per kilometre Pound per 1000 ft 0.6719 Newton Pound-force 0.2248

GLOSSARY 46 Amp (A) = Ampere: The unit of electric current. AC: Alternating current, e.g. 50 or 60 Hz AC power. ACR: Attenuation Crosstalk Ratio. The difference between attenuation and crosstalk. Important characteristic in transmission to assure that the transmitted signal is stronger at the receiving end of the cable than are any interference signals imposed on that same pair crosstalk from other pairs. Alpet: aluminium foil covered with polyester. Alu braid: braiding of woven aluminium wires ANSI: American National Standards Institute Attenuation: is the gradual loss in intensity of signals in electrical circuits. The unit of Attenuation is decibel. AWG: American wire gauge, is a standardized wire gauge system used since 1857 predominantly in the United States and Canada for the diameters of round, solid, nonferrous, electrically conducting wire. B.C. = BC: Bare Copper, mostly referring to a conductor or braid. Bending radius: the radius that a cable can be bend without any detrimental effects on transmission performance. Braid or Braiding: is a structure or pattern formed intertwining of commonly 16 strands of wires. B. S.: British Standards are the standards produced BSI Group which is incorporated under a Royal Charter (and which is formally designated as the National Standards Body (NSB) for the UK). Cable core: two or more wires or pairs stranded. Good twisting is necessary otherwise the cable can hardly be bend and will lose performance after a few bends. Category cables: high performance twisted pair cables for local area networking = structured wiring or cabling. Cables range from Cat 3 to Cat 7a. The higher the number, the greater the bandwidth and the better the performance. CCTV: Closed-circuit television is the use of video cameras to transmit a signal to a specifi c place, on a limited set of monitors. Circuit integrity: refers to the operability of electrical circuits during a fi re. It is a form of fi re-resistance rating. Coaxial Cable or coax: an electrical cable with a centre conductor surrounded a tubular insulating layer = the dielectric, surrounded a tubular conducting screen = the outer conductor, surrounded an outer sheath. The term coaxial comes from the centre conductor and the outer screen sharing the same geometric axis. : most familiar conductors are metallic. Copper or tinned copper is the most common material used for electrical wiring. Silver is also in use as a conductor and out performs copper, but is expensive. Crosstalk (XT): any phenomenon which a signal transmitted on one circuit of a transmission system creates an undesired effect in another circuit. Crosstalk is usually caused undesired capacitive, inductive, or conductive coupling from one circuit (mostly a pair) to another (pair). Current: electric current is a fl ow of electric charge through a medium. This fl owing electric charge is typically carried moving electrons in a conductor such as wire. The unit of current is Ampere. DC: Direct Current. DC Resistance: the resistance of an object is defi ned as the ratio of voltage across it to the direct current through it. The unit of resistance is Ohm. Dielectric: the insulation between centre and outer conductor (screen) of coaxial cables. Mostly solid or foam (= cellular) polyethylene (PE). Distortion: the alteration of the original shape (or other characteristic) of an object, image, sound, waveform or other form of information or representation. Distortion is usually unwanted, and often many methods are employed to minimize it in practice. Drain wire: a conductor in contact with the foil (of a screen) in order to terminate the screen. Also referred to a Continuity Wire. The preferred drain wire is tinned copper wire(s). Cat 3 Cable supports 10 Base-T Standard for bandwidths up to 10 Mbps over a maximum distance of 100 metres. They can support frequencies in the range up to 10 MHz. Cat 5/5e Cable supports 100 Base-T Standard for bandwidths up to 100 Mbps over a maximum distance of 100 metres. They can support frequencies in the range up to 100 MHz. Cat 5e cables can support 1000 Base-T as well. Cat 6 Cable supports 1000 Base-T Standard for bandwidths up to 1000 Mbps over a maximum distance of 100 metres. Cat 6 standard can support frequencies in the range up to 250 MHz. They also support 10GE (10Gig Ethernet) bandwidth over limited distances. Cat 6A Cable supports 10G Base-T standard for bandwidths up to 10 Gbps over a maximum distance of 100 metres. Cat 6A standard can support frequencies in the range up to 500 MHz. Cat 7 Cable supports 10G Base-T standard for bandwidths up to 10 Gbps over a maximum distance of 100 metres. Cat 7 standard can support frequencies in the range up to 600 MHz. It offers better performance and improved cross talk suppression over the Cat 6A cables. Decibel : is a logarithmic unit that indicates the ratio of a physical quantity (usually power or intensity) relative to a specifi ed or implied reference level. A ratio in decibels is ten times the logarithm to base 10 of the ratio of two power quantities. ELFEXT: the Equal-Level Far-End Crosstalk (ELFEXT) test measures Far-End Crosstalk (FEXT). FEXT is very similar to NEXT, but happens at the receiver side of the connection. Due to impedance on the line, crosstalk diminishes the signal as it gets further away from the transmitter. Because of this, FEXT is usually less detrimental to a signal than NEXT, but still important nonetheless. EIA: Electronic Industries Association. This body ceased operations on 28 February 2011. The former sectors of EIA are the Electronic Components Association (ECA), JEDEC, Government Electronics and Information Technology Association (GEIA), and are now part of TechAmerica, Telecommunications Industry Association (TIA), and Consumer Electronics Association (CEA). EN: European Norms maintained CEN (European Committee for Standardization), CENELEC (European Committee for Electrotechnical Standardization) and ETSI (European Telecommunications Standards Institute). Cat 7A Cable supports 10G Base-T standard for bandwidths up to 10 Gbps over a maximum distance of 100 metres. In addition to this, they can also support 40 Gbps bandwidth for around 50 metres and 100 Gbps bandwidth for around 15 metres. They support frequencies in the range up to 1000 MHz. Cat 8 Cable supports frequencies in the range up to 1200 MHz. Under development. No applications yet. CATV: Community Antenna Television, also often used to mean Cable TV. It is a system of providing television to consumers through or optical fi bre cables. High-speed Internet, telephony, and similar non television services may also be provided. Farad: the unit of capacitance. FPE: Foam Polyethylene (PE) = closed cells with gas in PE in order to reduce the dielectric constant. Often used as dielectric in coaxial cables. The gas may be generated chemical decomposition during extrusion of the insulation (chemical foaming or blowing) or injection into the polymer melt within the extruder (physical foaming or blowing). FAS Cables: cables for fi re detection and alarm systems Far end crosstalk (FEXT): Interference between two pairs of a cable measured at the other end of the cable from the transmitter. FR: can mean Flame Retardant or Fire Retardant or Fire Resistant.

Flame Retardant: are cables passing the vertical wire test of IEC 60332-1 or UL 1581 VW-1). Fire Retardant: are cables passing the bundle test of IEC 60332-2-24 or UL 1685 Vertical Tray. Fire Resistant: are cables with a circuit integrity of a specifi ed time. Frequency: is the number of occurrences of a repeating event per unit time. The unit of frequency is Hertz (Hz). G.P. Bus: General Purpose Bus Application Headroom: in case of testing category cables this is the average of the difference between worst case margin and the specifi ed value. Henry (H): unit of inductance. Hertz (Hz): unit of frequency. 1 Hz means that an event repeats once per second. HFFR = Halogen-Free, Flame or Fire Retardant Impedance: the ratio of voltage applied to the current is called the input impedance; the input impedance of the infi nite line is called the characteristic impedance. Insertion Loss: also referred to as attenuation, refers to the loss of signal strength at the far end of a line compared to the signal that was introduced into the line. This loss is due to the electrical resistance of the copper cable, the loss of energy through the cable insulation and the impedance caused the connectors. Insertion loss is usually expressed in decibels db with a minus sign. Insertion loss increases with distance and frequency. For every 6dB of loss, the original signal will be half the original amplitude. Inductance: is the property of an electrical circuit causing voltage to be generated proportional to the rate of change in current in a circuit. This property also is called self inductance to discriminate it from mutual inductance, describing the voltage induced in one electrical circuit the rate of change of the electric current in another circuit. Insulation: insulations are coating applied to conductor to isolate the conductors. Insulation materials are applied to provide good strippability. The physical properties are in accordance with BS EN 50290-2. Individually screened pair: a pair with a helically applied (= as a spiral) Aluminium/Polyester (Alpet) foil. A drain wire may also be included under the screen in Cat 7 cables. Jacket = sheath: This is the outer protective polymer surrounding the cable core. Power Sum ELFEXT (PSELFEXT): is the sum of FEXT values from 3 wire pairs as they affect the other wire pair. Pair: two twisted colour coded insulated wires. Quad: a four conductor cable core or unit, symmetrical stranded or twisted together. Rated Temperature: the maximum continuous temperature that the cable can withstand during its lifetime. It is generally limited the thermal aging characteristics of the plastics used to insulate and/or jacket the wire. Rated Voltage: the maximum voltage at which a cable can operate for extended periods without undue degradation or safety hazard. Resistance: the electrical resistance of a conductor measures its opposition to the passage of an electric current; the inverse quantity is electrical conductance, measuring how easily electricity fl ows along a certain path. The unit of electrical resistance is the ohm (Ω), while electrical conductance is measured in Siemens (S). Return Loss (RL): the Return or Refl ection Loss of a line is the ratio of the power refl ected back from the line to the power transmitted into the line. RL is expressed in decibels. The RL of coaxial cables is the loss of signal power resulting from the refl ection caused at a discontinuity in the cable. This discontinuity can be fl uctuations in dimensions and/or dielectric. Return Loss is also one of many parameters regulated the requirements established for Category 5e and onwards cables. It is a measure of the refl ected energy from a transmitted signal. The larger the value, the less energy that is refl ected. Poor Return Loss fi gures of a circuit are quite often caused poor termination (connectors). Screen: a cable screen acts as a Faraday cage to reduce electrical noise from affecting the signals, and to reduce electromagnetic radiation that may interfere with other parts in a cable or other cables. The screen minimizes capacitive coupled noise from other electrical sources. For more info regarding screens: see also the Technical Information section. Sheath: the outer covering of a cable, standard in accordance with BS EN 50290-2 and grey for PVC, purple for HFFR and black for PE. Shield = See Screen. SMATV = Satellite Master Antenna Television, and refers to a system that uses multiple satellite and broadcast signals to create a single integrated cable signal for distribution to a cabling network Solid BC: one solid conductor of bare copper. Solid TC: one solid conductor of tinned copper GLOSSARY 47 Lay-length: The length measured along the axis of a wire or cable required for a single strand (in stranded wire) or conductor (in cable) to make one complete turn about the axis of the conductor or cable. In a twisted pair cable, the lay length is the distance it takes for the two wires to completely twist around each other. Lay length is also known as pitch length. T.C. = TC = Tinned Copper TIA: the Telecommunications Industry Association is accredited the American National Standards Institute (ANSI) to develop voluntary industry standards for a wide variety of telecommunications products. Local Area Network (LAN): any communication network for connecting computers within a building or small group of buildings. m = metre: S.I. unit of measure of length MHz = Megahertz: 1 MHz = one million Hertz. Near End Crosstalk (NEXT): Interference between two pairs in a cable measured at the same end of the cable as the transmitter. Operating temperature (range): the temperature range across which the cable can operate. Polyolefien: is a polymer produced polymerisation of a simple olefi n (also called an alkene) as a monomer, for example Polyethylene or Polypropylene. PA = Polyamide PE = Polyethylene. PP = Polypropylene. PVC = Polyvinyl Chloride. Twisted pair: a type of wiring in which two conductors are twisted together for the purposes of cancelling out electromagnetic interference (EMI) from external sources; for instance, electromagnetic radiation from unshielded twisted pair (UTP) cables, and crosstalk between neighbouring pairs. Volt = Voltage = unit of electric, expressed with the symbol V. Wire = with Insulation and also referred to as a Core in some specifi cations.

ID.CHART n Ref. n Page SAS0201HBAXH C1001-B3 5100FE 21 SSS0201HBAXH C1002-B3 5100UE 21 SAS0301HBAXX C1003-B3 5101FE 21 SSS0301HBAXX C1004-B3 5101UE 21 SAS0401HBAXX C1005-B3 5102FE 21 SSS0401HBAXX C1006-B3 5102UE 21 SAS0203HBAXH C1007-B3 5200FE 21 SSS0203HBAXH C1008-B3 5200UE 21 SAS0303HBAXX C1009-B3 5201FE 21 SSS0303HBAXX C1010-B3 5201UE 21 SAS0403HBAXX C1011-B3 5202FE 21 SSS0403HBAXX C1012-B3 5202UE 21 SAS0205HBAXH C1013-B3 5300FE 21 SSS0205HBAXH C1014-B3 5300UE 21 SAS0305HBAXX C1015-B3 5301FE 21 SSS0305HBAXX C1016-B3 5301UE 21 n Ref. n Page MAS2075HEAAX-OIL C1090-B3 40 MAS0115HEAAX-OIL C1091-B3 40 MAS0215HEAAX-OIL C1092-B3 40 MAS0515HEAAX-OIL C1093-B3 40 MAS1015HEAAX-OIL C1094-B3 40 MAS2015HEAAX-OIL C1095-B3 40 MAS0150AEAAX-OIL C1096-B3 40 MAS0250AEAAX-OIL C1097-B3 40 MAS0550AEAAX-OIL C1098-B3 40 MAS1050AEAAX-OIL C1099-B3 40 MAS2050AEAAX-OIL C1100-B3 40 MAS0175AEAAX-OIL C1101-B3 40 MAS0275AEAAX-OIL C1102-B3 40 MAS0575AEAAX-OIL C1103-B3 40 MAS1075AEAAX-OIL C1104-B3 40 MAS2075AEAAX-OIL C1105-B3 40 n Ref. n Page SSS1501HEAAX-T C1146-B3 38 SSS2501HEAAX-T C1147-B3 38 SSS3601HEAAX-T C1148-B3 38 SSR0310HFESL-F3 C1149-B3 26 SSR0311HFESL-F3 C1150-B3 26 SSR0314HFESL-F3 C1151-B3 26 SSR0318HFESL-F3 C1152-B3 26 SSS0340HFESL-F3 C1153-B3 26 SSS0822HEAAX-T C1154-B3 38 SSS1222HEAAX-T C1155-B3 38 SSS2022HEAAX-T C1156-B3 38 SSS3622HEAAX-T C1157-B3 38 SSS0250HEAAX-T C1158-B3 38 SAR0310HFESL-F3 C1159-B3 26 SAR0311HFESL-F3 C1160-B3 26 SAR0314HFESL-F3 C1161-B3 26 SAS0405HBAXX C1017-B3 5302FE 21 SSS0405HBAXX C1018-B3 5302UE 21 SAS0206HBAXH C1019-B3 5400FE 21 SSS0206HBAXH C1020-B3 5400UE 21 MAS0115AEAAX-OIL C1106-B3 40 MAS0215AEAAX-OIL C1107-B3 40 MAS0515AEAAX-OIL C1108-B3 40 MAS1015AEAAX-OIL C1109-B3 40 SAR0318HFESL-F3 C1162-B3 26 SAS0340HFESL-F3 C1163-B3 26 STS0201HEAAX-T C1164-B3 38 STS0201HEAAX-T C1165-B3 38 48 SAS0306HBAXX C1021-B3 5401FE 21 SSS0306HBAXX C1022-B3 5401UE 21 MAS2015AEAAX-OIL C1110-B3 40 MAC0250HEAAX-OIL C1111-B3 41 SSS0601HEAAX-T C1166-B3 38 STS2501HEAAX-T C1168-B3 38 SAS0406HBAXX C1023-B3 5402FE 21 MAC0550HEAAX-OIL C1112-B3 41 STS3601HEAAX-T C1169-B3 38 SSS0406HBAXX C1024-B3 5402UE 21 MAC1050HEAAX-OIL C1113-B3 41 MAS0105HBEDX-T C1171-B3 19 RG59-FA C1025-B3 9100 29 MAC2050HEAAX-OIL C1114-B3 41 MAS0205HBEDX-T C1172-B3 19 RG6-FA C1026-B3 9116 29 MAC0275HEAAX-OIL C1115-B3 41 MAS0305HBEDX-T C1173-B3 19 RG11-FA C1027-B3 1523A 29 MAC0575HEAAX-OIL C1116-B3 41 MAS0405HBEDX-T C1174-B3 19 RG59 C1028-B3 543945 28 MAC1075HEAAX-OIL C1117-B3 41 MAS0505HBEDX-T C1175-B3 19 RG6 C1029-B3 533945 28 MAC2075HEAAX-OIL C1118-B3 41 MAS0605HBEDX-T C1176-B3 19 RG11 C1030-B3 513945 28 MAC0215HEAAX-OIL C1119-B3 41 STS0450HEAAX-T C1177-B3 38 Cat3-2P C1031-B3 1227A1 36 MAC0515HEAAX-OIL C1120-B3 41 STS0650HEAAX-T C1178-B3 38 Cat3-25P C1032-B3 1232A1 36 MAC1015HEAAX-OIL C1121-B3 41 STS1850HEAAX-T C1180-B3 38 Cat3-50P C1033-B3 36 MAC2015HEAAX-OIL C1122-B3 41 MAS0108HBAAH-T C1181-B3 9501 14 Cat3-100P C1034-B3 36 MAC0250AEAAX-OIL C1123-B3 41 MAS0208HBAAH-T C1182-B3 9502 14 UTPLevel5-4x2x0.22 C1035-B3 1583A 33 MAC0550AEAAX-OIL C1124-B3 41 MAS0308HBAAH-T C1183-B3 9503 14 FTPLevel5-4x2x0.22 C1036-B3 1633E 33 MAC1050AEAAX-OIL C1125-B3 41 MAS0408HBAAH-T C1184-B3 9504 14 UTPLevel6-4x2x0.22 C1037-B3 7965E 33 MAC2050AEAAX-OIL C1126-B3 41 MAS0508HBAAH-T C1185-B3 9505 14 FTPLevel6-4x2x0.22 C1038-B3 7860E 33 MAC0275AEAAX-OIL C1127-B3 41 MAS0608HBAAH-T C1186-B3 9506 14 SFTPLevel7 C1039-B3 1885ENH 34 MAC0575AEAAX-OIL C1128-B3 41 MAS0708HBAAH-T C1187-B3 9507 14 SAR0203HFCCH C1040-B3 9574 24 MAC1075AEAAX-OIL C1129-B3 41 MAS0808HBAAH-T C1188-B3 9508 14 SAR0202HFCCH C1041-B3 9575 24 SAR0201HFCCH C1042-B3 9581 24 MAC2075AEAAX-OIL C1130-B3 41 MAC0215AEAAX-OIL C1131-B3 41 MAR0108HBADX-T C1189-B3 9841 12 MAR0208HBADX-T C1190-B3 9842 12 SAR0252HFCCH C1043-B3 9583 24 MAC0515AEAAX-OIL C1132-B3 41 MAR0308HBADX-T C1191-B3 9843 12 SAR0214HFESL-F3 C1044-B3 26 MAC1015AEAAX-OIL C1133-B3 41 MAR0408HBADX-T C1192-B3 9844 12 SAR0218HFESL-F3 C1045-B3 26 MAC2015AEAAX-OIL C1134-B3 41 MAS0105HBAAN-T C1193-B3 8760 18 UFTPLevel6-4x2x0.22 C1053-B3 34 SSR0203HFCCH C1135-B3 9571 24 MAS0106HBAAN-T C1195-B3 8762 18 MAR0107HBADX-T C1080-B3 3105A 12 SSR0202HFCCH C1136-B3 9572 24 MAP0207HBADX-T C1196-B3 8723 17 MAS0150HEAAX-OIL C1081-B3 40 SSR0201HFCCH C1137-B3 9580 24 MAP0307HBADX-T C1197-B3 8777 17 MAS0250HEAAX-OIL C1082-B3 40 SSR0252HFCCH C1138-B3 9582 24 MSE0103HBAAN-T C1198-B3 8471 18 MAS0550HEAAX-OIL C1083-B3 40 SSR0210HFESL-F3 C1139-B3 26 MAS0107HBAAN-T C1199-B3 8761 18 MAS1050HEAAX-OIL C1084-B3 40 SSR0211HFESL-F3 C1140-B3 26 UUTPLevel6-4x2x0.22 C1200-B3 34 MAS2050HEAAX-OIL C1085-B3 40 SSR0214HFESL-F3 C1141-B3 26 SFTPLevel7-ZA C1201-B3 34 MAS0175HEAAX-OIL C1086-B3 40 SSR0218HFESL-F3 C1142-B3 26 MSE0105HBAAN-T C1203-B3 9740 18 MAS0275HEAAX-OIL C1087-B3 40 SSS0240HFESL-F3 C1143-B3 26 SAS0605HBAXX C1211-B3 5304FE 21 MAS0575HEAAX-OIL C1088-B3 40 STS0601HEAAX-T C1144-B3 38 SSS0605HBAXX C1212-B3 5304UE 21 MAS1075HEAAX-OIL C1089-B3 40 SSS0901HEAAX-T C1145-B3 38 MAS0103HBAAN-T C1213-B3 8719 18

n Ref. n Page MAP0607HBADX-T C1214-B3 8778 17 MAS0208HIADH C1217-B3 YE00820 15 MAS0208HIEDH C1218-B3 YE00906 15 MAS0108HIADH C1219-B3 YE00819 15 MAS0108HIEDH C1220-B3 YE00905 15 MSE0101HBAAN-T C1222-B3 8473 18 MAS0101HBAAN-T C1224-B3 8720 18 SAS0207HBAXH C1226-B3 5500FE 21 SSS0207HBAXH C1227-B3 5500UE 21 SAS0307HBAXX C1228-B3 5501FE 21 RG59-FTC C1229-B3 1505A 30 SAS0407HBAXX C1230-B3 5502FE 21 SSS0407HBAXX C1231-B3 5502UE 21 SAS0837HBAXX C1232-B3 5506FE 21 SSS0807HBAXX C1233-B3 5506UE 21 UTPLevel5-4x2x0.22ZA C1235-B3 33 n Ref. n Page - - - - - - - - - - - - SAS0240HFESL-F3 C1289-B3 26 MAR0207HBADX-T C1295-B3 3107A 12 MAR0307HBADX-T C1296-B3 3108A 12 MAR0407HBADX-T C1297-B3 3109A 12 MSE0106HBAAN-T C1300-B3 8205 18 MSE0107HBAAN-T C1301-B3 8442 18 MSE0152HBAAN-T C1302-B3 8477 18 MAS0152HXEDN-T C1303-B3 8718NH 18 MSE0152HXEDN-T C1304-B3 8477NH 18 MAS0101HXEDN-T C1305-B3 8720NH 18 MSE0101HXEDN-T C1306-B3 8473NH 18 MSE0103HXEDN-T C1307-B3 8471NH 18 MAS0106HXEDN-T C1308-B3 8762NH 18 n Ref. n Page SAS0403HXEDX C1715-B3 4202FE 22 SSS0403HXEDX C1716-B3 4202UE 22 SAS0603HXEDX C1717-B3 4204FE 22 SSS0603HXEDX C1718-B3 4204UE 22 SAS0803HXEDX C1719-B3 4206FE 22 SSS0803HXEDX C1720-B3 4206UE 22 SAS0205HXEDH C1721-B3 4300FE 22 SSS0205HXEDH C1722-B3 4300UE 22 SAS0305HXEDX C1723-B3 4301FE 22 SSS0305HXEDX C1724-B3 4301UE 22 SAS0405HXEDX C1725-B3 4302FE 22 SSS0305HXEDX C1726-B3 4302UE 22 SAS0605HXEDX C1727-B3 4304FE 22 SSS0605HXEDX C1728-B3 4304UE 22 SAS0805HXEDX C1729-B3 4306FE 22 SSS0805HXEDX C1730-B3 4306UE 22 ID.CHART FTPLevel5-4x2x0.22ZA C1236-B3 33 MSE0106HXEDN-T C1309-B3 8205NH 18 SAS0206HXEDH C1731-B3 4400FE 22 UTPLevel6-4x2x0.22ZA C1237-B3 33 MAS0107HXEDN-T C1310-B3 8761NH 18 SSS0206HXEDH C1732-B3 4400UE 22 FTPLevel6-4x2x0.22ZA C1238-B3 33 MSE0107HXEDN-T C1311-B3 8442NH 18 SAS0306HXEDX C1733-B3 4401FE 22 RG11-QS C1241-B3 1617A 29 MAS0152HBAAN-T C1313-B3 18 SSS0306HXEDX C1734-B3 4401UE 22 SAS0601HBAXX C1248-B3 5104FE 21 SSS0601HBAXX C1249-B3 5104UE 21 SAS0801HBAXX C1250-B3 5106FE 21 MAP0607HBEDX-T C1314-B3 8778NH 17 MAR0108HXEDX-T C1318-B3 9841NH 12 MAR0208HXEDX-T C1319-B3 9842NH 12 SAS0406HXEDX C1735-B3 4402FE 22 SSS0406HXEDX C1736-B3 4402UE 22 SAS0606HXEDX C1737-B3 4404FE 22 49 SSS0801HBAXX C1251-B3 5106UE 21 MAR0308HXEDX-T C1320-B3 9843NH 12 SSS0606HXEDX C1738-B3 4404UE 22 SAS0603HBAXX C1252-B3 5204FE 21 MAR0408HXEDX-T C1321-B3 9844NH 12 SAS0806HXEDX C1739-B3 4406FE 22 SSS0603HBAXX C1253-B3 5204UE 21 SAS0252HBAXH C1322-B3 5000FE 21 SSS0806HXEDX C1740-B3 4406UE 22 SAS0803HBAXX C1254-B3 5206FE 21 SSS0252HBAXH C1323-B3 5000UE 21 SAS0207HXEDH C1741-B3 4500FE 22 SSS0803HBAXX C1255-B3 5206UE 21 SAS0352HBAXX C1324-B3 21 SSS0207HXEDH C1742-B3 4500UE 22 RG59-QS C1256-B3 29 SSS0352HBAXX C1325-B3 21 SAS0307HXEDX C1743-B3 4501FE 22 RG6-QS C1257-B3 29 SAS0452HBAXX C1326-B3 21 SSS0307HXEDX C1744-B3 4501UE 22 SAS0805HBAXX C1258-B3 5306FE 21 SSS0452HBAXX C1327-B3 21 SAS0407HXEDX C1745-B3 4502FE 22 SSS0805HBAXX C1259-B3 5306UE 21 SAS0652HBAXX C1330-B3 21 SSS0407HXEDX C1746-B3 4502UE 22 SAS0606HBAXX C1260-B3 5404FE 21 SSS0652HBAXX C1331-B3 21 SAS0607HXEDX C1747-B3 4504FE 22 SSS0606HBAXX C1261-B3 5404UE 21 SAS0852HBAXX C1332-B3 21 SSS0607HXEDX C1748-B3 4504UE 22 SAS0806HBAXX C1262-B3 5406FE 21 SSS0852HBAXX C1333-B3 21 SAS0807HXEDX C1749-B3 4506FE 22 SSS0806HBAXX C1263-B3 5406UE 21 SAS0252HXEDH C1334-B3 4000FE 22 SSS0807HXEDX C1750-B3 4506UE 22 SAS0637HBAXX C1264-B3 5504FE 21 SSS0252HXEDH C1335-B3 4000UE 22 SSS0607HBAXX C1265-B3 5504UE 21 SAS0352HXEDX C1336-B3 4001UE 22 Cat3-6P C1266-B3 36 SSS0352HXEDX C1337-B3 22 Cat3-12P C1267-B3 36 SAS0452HXEDX C1338-B3 22 Cat3-150P C1268-B3 36 SSS0452HXEDX C1339-B3 22 Cat3-200P C1269-B3 36 SAS0652HXEDX C1342-B3 22 MAS0103HXEDN-T C1270-B3 8719NH 18 SSS0652HXEDX C1343-B3 22 MSE0105HXEDN-T C1271-B3 9740NH 18 SAS0852HXEDX C1344-B3 22 MAS0105HXEDN-T C1272-B3 8760NH 18 SSS0852HXEDX C1345-B3 22 RG59-FLEX C1275-B3 9259 28 MSE0107HXEDX C1346-B3 7701NH 16 RG6-FLEX C1276-B3 28 MSE0207HXEDX C1347-B3 7702NH 16 RG11-FLEX C1277-B3 28 MAS0107HXEDX C1348-B3 7703NH 16 SSS0307HBAXX-B3 C1278-B3 5501UE 21 MAC0207HXEDX C1349-B3 7704NH 16 RG6-FTC C1279-B3 1694A 30 SAS0205HBOXH C1351-B3 23 RG11-FTC C1280-B3 7731A 30 SAS0305HBOXH C1352-B3 23 MAP0207HBEDX-T C1281-B3 8723NH 17 SAS0405HBOXH C1353-B3 23 MAP0307HBEDX-T C1282-B3 8777NH 17 SAS0605HBOXH C1354-B3 23 SAR0211HFESL-F3 C1283-B3 26 SAS0805HBOXH C1355-B3 23 SAR0210HFESL-F3 C1284-B3 26 SAS1005HBOXH C1356-B3 23 - - - SAS2005HBOXH C1357-B3 23

ID.CHART n Ref. n Page SSS0201HEAAX-T C1360-B3 38 SSS0201HEAAX-T C1361-B3 38 SSS0401HEAAX-T C1362-B3 38 SSS5001HEAAX-T C1364-B3 38 STS5001HEAAX-T C1365-B3 38 SSS0222HEAAX-T C1366-B3 38 SSS0322HEAAX-T C1367-B3 38 SSS0422HEAAX-T C1368-B3 38 SSS0622HEAAX-T C1369-B3 38 SSS0350HEAAX-T C1370-B3 38 SSS0450HEAAX-T C1371-B3 38 SSS0650HEAAX-T C1372-B3 38 SSS1250HEAAX-T C1373-B3 38 SSS1850HEAAX-T C1374-B3 38 STS1250HEAAX-T C1375-B3 38 RG59-ZA-FTC C1378-B3 30 RG6-ZA-FTC C1379-B3 30 RG11-ZA-FTC C1380-B3 30 MAP0208HBADX-T C1382-B3 9729 13 MAP0308HBADX-T C1383-B3 9730 13 n Ref. n Page SSS0375HBAAC C1631-B3 43 SSS0310HBAAC C1632-B3 43 SSS0315HBAAC C1633-B3 43 SSS0325HBAAC C1634-B3 43 SSS0475HBAAC C1635-B3 43 SSS0410HBAAC C1636-B3 43 SSS0415HBAAC C1637-B3 43 SSS0425HBAAC C1638-B3 43 SSS0515HBAAC C1639-B3 43 SSS0525HBAAC C1640-B3 43 SSS0715HBAAC C1641-B3 43 SSS0725HBAAC C1642-B3 43 SSS0815HBAAC C1643-B3 43 SSS0825HBAAC C1644-B3 43 SSS1275HBAAC C1645-B3 43 SSS1215HBAAC C1646-B3 43 SSS1225HBAAC C1647-B3 43 SSS1875HBAAC C1648-B3 43 SSS1815HBAAC C1649-B3 43 SSS1825HBAAC C1650-B3 43 50 MAP0408HBADX-T C1384-B3 9728 13 MAP0608HBADX-T C1386-B3 13 SAS0203HBOXH C1391-B3 23 SAS0303HBOXH C1392-B3 23 SAS0403HBOXH C1393-B3 23 SAS0603HBOXH C1394-B3 23 SAS0803HBOXH C1395-B3 23 SAS1003HBOXH C1396-B3 23 SAS2003HBOXH C1397-B3 23 RG59-ZA C1428-B3 28 RG6-ZA C1429-B3 28 RG11-ZA C1430-B3 28 STS0422HEAAX-T C1471-B3 38 STS0622HEAAX-T C1472-B3 38 STS0822HEAAX-T C1473-B3 38 STS1222HEAAX-T C1474-B3 38 STS2022HEAAX-T C1475-B3 38 STS3622HEAAX-T C1476-B3 38 UTPLevel5-4x2x0.22-Patch C1500-B3 35 UTPLevel5-4x2x0.22ZA-Patch C1510-B3 35 STS0210ABAAC C1651-B3 43 STS0215ABAAC C1652-B3 43 STS0375ABAAC C1655-B3 43 STS0310ABAAC C1656-B3 43 STS0315ABAAC C1657-B3 43 STS0325ABAAC C1658-B3 43 STS0340ABAAC C1659-B3 43 STS0410ABAAC C1660-B3 43 STS0415ABAAC C1661-B3 43 STS0425ABAAC C1662-B3 43 STS0440ABAAC C1663-B3 43 STS0460ABAAC C1664-B3 43 STS0510ABAAC C1665-B3 43 STS0515ABAAC C1666-B3 43 STS0615ABAAC C1668-B3 43 STS0710ABAAC C1669-B3 43 STS0715ABAAC C1670-B3 43 STS1210ABAAC C1671-B3 43 STS1215ABAAC C1672-B3 43 STS1810ABAAC C1673-B3 43 FTPLevel5-4x2x0.22-Patch C1520-B3 35 FTPLevel5-4x2x0.22ZA-Patch C1530-B3 35 STS1815ABAAC C1674-B3 43 STS2510ABAAC C1675-B3 43 UTPLevel6-4x2x0.22-Patch C1540-B3 35 UTPLevel6-4x2x0.22ZA-Patch C1550-B3 35 FTPLevel6-4x2x0.22-Patch C1560-B3 35 FTPLevel6-4x2x0.22ZA-Patch C1570-B3 35 STS0375HBAAC C1620-B3 43 STS0310HBAAC C1621-B3 43 STS0315HBAAC C1622-B3 43 STS0325HBAAC C1623-B3 43 STS0475HBAAC C1624-B3 43 STS0410HBAAC C1625-B3 43 STS0415HBAAC C1626-B3 43 STS0425HBAAC C1627-B3 43 STS0515HBAAC C1628-B3 43 STS0525HBAAC C1629-B3 43 SAS0201HXEDH C1701-B3 4100FE 22 SSS0201HXEDH C1702-B3 4100UE 22 SAS0301HXEDX C1703-B3 4101FE 22 SSS0301HXEDX C1704-B3 4101UE 22 SAS0401HXEDX C1705-B3 4102FE 22 SSS0401HXEDX C1706-B3 4102UE 22 SAS0601HXEDX C1707-B3 4104FE 22 SSS0601HXEDX C1708-B3 4104UE 22 SAS0801HXEDX C1709-B3 4106FE 22 SSS0801HXEDX C1710-B3 4106UE 22 SAS0203HXEDH C1711-B3 4200FE 22 SSS0203HXEDH C1712-B3 4200UE 22 SAS0303HXEDX C1713-B3 4201FE 22 SSS0303HXEDX C1714-B3 4201UE 22

COUNTRY PROJECT CONTRACTOR TYPE OF CABLE RUSSIA ST. PETERSBURG AIRPORT ALFA IMPORT LAN CABLES TELEPHONE CABLES UAE DUBAI MARINA MOTT MCDONALD LOUD SPEAKER CABLES - FIRE RESISTANT CABLES IRAQ IRAQ (BASSORA) SHERATON HOTEL RAMFIRECRO - F3 FIRE PLANET LEBANON LEBANON ABC MALL MAC CORP RAMFIRECRO - F3 FIRE PLANET LEBANON LEBANON SOUKS OF BEIRUT MAC CORP RAMFIRECRO - F3 FIRE PLANET BULGARIA MINISTRY OF INTERNAL AFFAIRS TELETEK SECURITY ALARM CABLES BOSNIA AND HERZEGOVINA CENTRAL BANK A.F.P. d.o.o. Security, fire alarm and fire resistant Cables BOSNIA AND HERZEGOVINA HYPO ALPE, ADRIA-BANK DD, MOSTAR A.F.P. d.o.o. Security, fire alarm and fire resistant Cables BOSNIA AND HERZEGOVINA JP ELEKTROPRIVREDA, MOSTAR A.F.P. d.o.o. Security, fire alarm and fire resistant Cables BOSNIA AND HERZEGOVINA JP HT - ERONET, MOSTAR A.F.P. d.o.o. Security, fire alarm and fire resistant Cables BOSNIA AND HERZEGOVINA UNICREDIT BANK, MOSTAR A.F.P. d.o.o. Security, fire alarm and fire resistant Cables ISLAND HELLISHEIDI POWER STATION S.G. - S. GUDJONSSON EHF SIGNAL AND CONTROL HALOGEN FREE CABLES ABU DHABI AL SALAM TUNNEL MUNICIPALITY OF ABU DHABI / SIRTI SPECIAL HYBRID CABLE PROJECT LIST 51

N O T E S 52