SPECIFICATION NO NOTE

Similar documents
SPECIFICATION NO Model 207 Automatic GTAW Welding System

MODEL 227 POWER SUPPLY

515 PIPEMASTER. Features. Options PROGRAMMABLE POWER SOURCE FOR ORBITAL WELD HEADS

Modular Lube Lubrication Systems System Controls

Engineered to meet your needs T he oldest name in stud welding,

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Label Applicator HERMA 400

Cooling systems for ORBIMAT

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

ARC HEIGHT CONTROL (ARC VOLTAGE CONTROL) MODEL : HAC-01-A-1M

Part-Turn Electric Multi-Turn Electric

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

SHARP Plasma inverter cutting range

Stud Welding Equipment

Operating Instructions

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

INSTRUCTION MANUAL COMMANDER BDH MIG

PRESTOJET Plasma inverter cutting range

XMT 350 FieldPro Systems

ex 800 Series ematrix System

CITOCUT Plasma inverter cutting range

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate V3. Coolant systems are warranted for 1 year, parts and labor.

AF-300 E11 Adjustable Frequency Drive

INSTRUCTION MANUAL. J800 Weld Controller. 3/25/2018 Revision

Noise Detector ND-1 Operating Manual

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

Flat-Bed Module Recorders

CITOCUT Plasma inverter cutting range

I/A Series Hardware Fiber Optic LAN Converter

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

2.9 Sigma/ 2 Plunger Metering Pumps

MICROMASTER Encoder Module

MinarcTig Evo 200MLP

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Table of Contents. Amplifiers Broadband Telecommunications Line Extender [BLE-75**] FEATURES

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

PORTABLE TYPE ARC WELDING MACHINE

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

PROFESSIONAL 2 CHANNEL SOLID-STATE MIC / LINE PREAMPLIFIER USER S MANUAL

Luminaire installation box Surface-mounted box Ceiling installation box

SCALE & WEIGHT DISPLAYS

1/3 RACK-MOUNTED BLOCK CONVERTERS

MULTIBAND 1/3 RACK-MOUNTED

Winmate Communication INC.

TUSKIN Equipment Corporation

Gamma instabus. Technical product information

Circuit-Breakers for Motor Protection Series 8523/8

WELDING CONTROL UNIT: TE 450 USER MANUAL

e-vap 3kW Evaporation Sources

800 Displaying Series Flowmeter

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

Signet 2250 Hydrostatic Level Sensor

KEMPPI K5 WELDING EQUIPMENT. Kempact Pulse 3000 QUALITY, SPEED AND PRODUCTIVITY

Type MG-6 Auxiliary Relay Class 1E

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

UNIT V 8051 Microcontroller based Systems Design

Product Description Sheet Loctite CL10 Quad LED Controller

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

Single Axis Position Controller

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

USER & ENGINEER INSTRUCTION MANUAL

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

R-1580A Microwave Downconverter. Product Brochure

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

CTC Series. Compact Temperature Calibrator

P P S - M W S C A N 1 H

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

ADJUSTABLE SPEED DRIVES. nc1 Drive

Product Data Sheet 4656 EZ

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

Series 1100 ColorTS Servo Manual Registration System

FLOMAT Electromagnetic Insertion Flowmeter

X-Band Redundant LNB Systems

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

PipeWorxFieldPro System

Session 1 Introduction to Data Acquisition and Real-Time Control

Multi-functional safety relay modules PROTECT SRB-E

Processes TIG (GTAW) Pulsed TIG (GTAW-P) Stick (SMAW) Air carbon arc (CAC-A) 400: 1/4 in. maximum 800: 3/8 in. maximum

istep STEPPER MOTOR PUMP

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

TELEDYNE HASTINGS INSTRUMENTS

Advanced Test Equipment Rentals ATEC (2832)

INSTALLATION MANUAL. ION Series FIBER OPTIC ILLUMINATOR IP67 OUTDOOR RATED

VarioSynergic 3400 / 4000 / 5000 VarioSynergic / / MIG/MAG welding PERFECT WELDING

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Section C Recorders. DPR mm Digital Strip Chart Recorder

Transcription:

NOTE The Model 207-1 is a special version of the standard M-207 Power Supply. It has been altered for a special applications requiring low current operation at high arc voltages in ambient and pressurized helium atmospheres. Other than specification changes for output current and voltage the M-207-1 contains the same features as the standard M- 207. 1.0 Introduction The Model 207-1 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small size makes it especially useful in field applications where portability is required. It is intended for (but not limited to) totally Automatic Fusion (Autogenous) Welding of tube, pipe and fittings using AMI Model 9 Tube Welding Heads. The M-207-1 employs a constant-current Line Inverter as the Weld Current Power source and a 16-bit microprocessor with memory for control of all system functions. All functions are accurate and repeatable to better than +/- 1% providing that line voltage fluctuations and ambient temperature are within the stated limits. All Welding Function parameters (weld schedules) are entered via the computer key pad and display. All steps for entering these values are prompted by the display in plain language, no computer language or codes are needed. Weld Parameters for each specific application are only entered one time and are then retained within the system memory (by schedule number). The M-207-1 is built in a rugged housing that is designed to be portable. Operating AC power is supplied by line cord and gas is supplied by flexible hosing, so permanent connections are not required. The system requires an inert gas source with pressure regulator and flow meter (not supplied). The Chassis and Power Source are air-cooled. Torches and Weld Heads requiring Liquid cooling must use the Model 207-CW Modular Cooling Option which attaches to the M-207-1 to retain System portability. This specification details operating ranges, construction and general use. For specific information about Operation consult the Model 207 Operation Manual. 2.0 Features And System Configuration 1. Standard Features - The following are general features described in this specification: 1. All functions are Microprocessor controlled. 2. Memory storage for up to 100 Weld Procedures. 3. Ability to create, copy and modify schedules. 4. 100 Amperes of Straight Polarity GTAW current. Rev. 17 December 2012 Page 1 of 9

2.0 Features and System Configuration (continued) 5. Pulsed Current Controls form 0.05 to 50 PPS. 6. Multi-Levels of Pulsed Current Values. 7. Continuous or Stepped Arc Rotation controls. 8. Operates all AMI Model 9 Fusion Welding Heads 9. Operates Manual Welding Torch. 10. Complete Automatic Operation and Timing Controls including Prepurge, Postpurge, Upslope, downslope, Rotation Delays and Level Times. 11. Built-in Fault checks for the system Status and common operation errors (Gas Check, Coolant Check, etc.). 12. Multi-lingual Display Instructions in English, French or German (other languages will be available at later dates). 13. Built-in Printer for recording Weld Procedures. 2. System Configuration 1. Main Power Supply Console including: 1. 25 foot Input Power Cord 2. 100 Ampere Inverter Power Source 3. Computer Memory Module 4. Main Computer Electronics (weld functions) 5. Input Gas Panel (two port) 6. Weld Head Connect Panel including Ground, Electrode, Weld Head Electrical Connectors and two (2) Gas Output Connectors and Remote Pendant and Auxiliary Connector. 7. 2 Line by 40 Character Display (2 each) 8. Membrane Key Panel including Numeric Keys and all Set Up, Start/Stop Keys (jog, purge, etc.) and Program Selection Keys 9. Printer 2. 15-Foot Weld Adapter Cable including 1. Weld Head Arc Gas Hose 2. Electrode Cable 3. Ground Cable 4. Weld Head Electrical Cable 3. Enclosure Physical Construction 1. Material: Aluminum 2. Height: 10.9 (276.9 mm) cover closed. 9.3 (236.2 mm) cover removed. 3. Width: 22.75 (577.9 mm). Rev. 17 December 2012 Page 2 of 9

3. Enclosure Physical Construction (continued) 4. Depth: 19.25 (489.0 mm) including handle. 5. Weight: 78 lbs ( 35.4 kg) 3.0 Input Power, Inert Gas And Temperature Requirements 1. Input Power: The M-207-1, as standard, can operate on a variety of Single Phase AC input power as follows: 100 VAC +32%, -10%, 50/60 Hz, 30 ampere service. 110 VAC +20%, -18%, 50/60 Hz, 30 ampere service. 115 VAC +15%, -22%, 50/60 Hz, 30 ampere service. 120 VAC +10%, -25%, 50/60 Hz, 30 ampere service. 200 VAC +32%, -10%, 50/60 Hz, 20 ampere service. 208 VAC +27%, -13%, 50/60 Hz, 20 ampere service. 220 VAC +20%, -18%, 50/60 HZ, 20 ampere service. 230 VAC +15%, -22%, 50/60 Hz, 20 ampere service. 240 VAC +10%, -25%, 50/60 Hz, 20 ampere service. +/- % indicates the allowable input voltage fluctuation to maintain performance as specified. Ampere service rating is based on maximum welding current output with maximum Arc Voltage. 2. Inert Gas: The Model 207-1 is a Gas Tungsten Arc Welding (GTAW) Power Source only and as such requires Inert or Inert/Active Mixed Gas for operation. The Gas Line is provided with a Automatic/Manual Solenoid which controls the Pre Weld, Weld Post Weld purging of the Weld Zone. Input gas pressure must be regulated, by the user, to a maximum of 50 PSI +/- 5 PSI (3.4 +/- 0.3 bar). Connection to the Gas Source is via color coded impermeable Hosing (to prevent oxygen and water diffusion) and standard 5/8-16 NPT Gas fittings. Connection to the Gas Source is via color coded impermeable Hosing (to prevent oxygen and water diffusion) and standard 5/8-16 NPT Gas fittings. 3. Temperature - The M207-1 is designed to operate in an ambient temperature range between 0 degrees C (32 F) and 45 degrees C (110 F). 4.0 Weld Current Source And Controls 1. Output Current: 5 to 100 Amperes on 200 Amperes on 200 to 240 VAC. 5 to 70 Amperes on 100 to 120 VAC 2. Voltage: 75 to 80 VDC Open circuit (no current) depending on input VAC value. 30 VDC Maximum at 100 amperes. 43 VDC Maximum at 5 amperes. 3. Regulation: Constant Current, Straight Polarity. +/- 1% of program setting or 0.5 Ampere (whichever is greater) with input power fluctuations of +/- 10%. Rev. 17 December 2012 Page 3 of 9

4.0 Weld Current Source and Controls (continued) 4. Regulation Type: Line Inverter using 35 KHz switching frequency, closed loop, real time monitoring with solid-state, High-Speed switching regulation devices. 5. Duty Cycle: 100% at specified operating temperature and specified input VAC. 6. Current Controls: The system provides two (2) methods of Current Operation: Continuous (Cont.) Mode or Pulsed Mode. The Cont. Mode sets the system to regulate a single desired value of current. In the Pulsed Mode the System will automatically pulse between one desired current and another to perform pulsed arc welding. 5.0 Pulsed Arc Current In addition, the system provides (in either mode) the ability to automatically program changes in the current value. These changes are called Levels and the System can provide up to 100 Level changes per Automatic Weld Sequence. The desired Current Values, Current Mode, desired Pulsation Rate (pulse times) and Current Level values are entered into microprocessor memory (via key pad) and files by weld number/type/description. If desired, two (2) current values can be selected. The high current is designated the Primary current and the low current is designated the Background current. The frequency or pulse rate of switching between these currents is controlled by the Primary and Background Pulse time function with the following range: Primary Pulse Time - 0.01 to 10.00 Seconds, +/- 0.001 Background Pulse Time - 0.01 to 10.00 Seconds, +/- 0.001 This equates to a pulse frequency range of 0.05 to 50.00 pulses per second. Pulse width adjustment is a function of the Primary time versus the Background time. 6.0 Fixture Rotation Servo And Controls The M-207-1 is intended to (but not limited to) operate Model 9 Fusion Tube Welding Heads. These Heads encapsulate the Weld Zone (with inert gas) and the welding Arc (electrode) is rotated around the stationary Tube, Pipe or fitting to be welded. The M-207-1 is equipped standard with a Rotation Servo and controls to drive the Weld Head Rotation Motor. 1. Rotation Speed = 0.10 to 20.00 RPM There are over 23 versions of Model 9 Weld Heads and not all Heads have the same Rotation Speed Ranges. Rev. 17 December 2012 Page 4 of 9

6.0 Fixture Rotation Servo and Controls (continued) 2. Rotation Regulation - Closed-Loop Servo using Tachometer Feed-Back with regulation to +/- 1%*. * The Servo is rated to +/- 1% over its specified range, however, some M-9 Weld Heads have Low Speed minimums greater than 1%. Consult the individual Head Specification for details. 3. Rotation Controls - The System provides two (2) methods of Rotation Control: Continuous (Cont) Mode and Stepped Mode. The Cont. Mode sets the system to regulate a single desired value of speed. In the Stepped Mode the System will automatically pulse between a desired Primary speed and a desired background speed to perform Stepped arc welding. The Stepping is Synchronized to the Current Pulsation s. The desired Speed Value and Speed Mode are entered into the microprocessor memory (via key pad) and filed by weld number/type/description. 7.0 Arc Start System A High Frequency (HF) Arc Starter is provided, with a booster that momentarily increases the open circuit voltage during Arc Start. The HF Starter will reliably start the arc at current levels of 5 amperes or greater in a 1 BAR atmosphere of Argon or Helium using a suitably prepared thoriated or ceriated Tungsten Electrode with an Arc Gap of 0.025 inch or less and torch cables of 25 feet or less. Protective devices are installed in the HF Starter and at suitable points in the system to prevent HF feed through to power lines or to internal, sensitive components. 8.0 Metering During the Weld Sequence one of the Displays provides sliding Scale Indicators which displays Amperes, Arc Volts and Rotation Speed. The Meters are intended as an information and trouble shooting guide and are not intended to be used for Quality Control or calibration purposes. 9.0 Microprocessor The M-207-1 contains a 16 bit Microprocessor with BATRAM memory. The microprocessor is supplied with operating software which supplies all of the Standard functions of this Specification. All Standard commands are inputted into the microprocessor via the Display Panel Keys. All steps of operation and programming are prompted by the Displays (in English, French, or German) contained on the Display Panel. 10.0 EMI Suppression The M-207-1 is equipped with a heavy-duty Pi-Network filter, connected to the input power line, to prevent propagation of EMI either into or out of the M-207-1. All-metal enclosures and internal shields prevent radiated EMI. Rev. 17 December 2012 Page 5 of 9

11.0 Operation, Modes SPECIFICATION NO. 207-1 The M-207-1 has three (3) basic mode of operation. The modes are selected via a 3-way Keylock Mode Switch. The key can be removed to lock the system into any of its three modes as described below: 1. Operate Mode: The Operate Mode is really two-fold: Non Welding Functions and Automatic Weld Sequence. The following describes these two Operate Modes: Non Welding 1. Operator selection of any one of the possible 100 Weld Schedules contained in the System Memory. 2. Operator Override control for Current and Rotation Speed. Limits to Override can be pre-programmed (see Programming). 3. Weld Set-Up Controls for Jogging the Weld Head Electrode to the desired Start Position. 4. Manual Purge Controls for Jogging the Weld Head Electrode to the desired Start Position. 5. Manual Sequence Stop for Operator interruption of normal Weld Sequence without normal Stopping Sequence (Post Purge only). 6. All Stop function for Operator interruption of normal Stopping Sequence (Post Purge only). 7. Automatic Fault Detection for Gas Flow, Coolant Flow, overheating, etc. Engages All Stop Automatically. Automatic Weld Sequence: Sequence Start is initiated by the Operator and the following Events occur Automatically in the sequence described below: 8. Prepurge Time: 0 to 99 Seconds with automatic initiation of Arc Gas Solenoid at beginning of Sequence. 9. Arc Initiation (after prepurge): via Impulse HF Starter. 10. Arc Detection: After Arc Initiation the M-207-1 will detect if there is an Arc. If Arc Start is not successful it will notify the Operator to start over; if successful, the following will all Start at the Same Time. Current Upslope Time: 00.0 to 99.9 Seconds. The current will rise during this time to its maximum programmed value. Rotation Start Delay Time: 0.0 to 99.9 Seconds. Arc Rotation will be delayed for the programmed time to achieve penetration before moving. Pulsation Timers: 0.01 to 9.99 Primary 0.01 to 9.99 Background If Pulse Mode is programmed the Current will start to pulse at the programmed rate. Rev. 17 December 2012 Page 6 of 9

11.0 Operation Modes (continued) 10. (continued) Level 1 Time: SPECIFICATION NO. 207-1 000 to 999 Seconds This programmed function sets the period of time that the level 1 Primary current value will be used before switching to Level 2 or the End of Sequence. 11. Levels: After Upslope the Primary Current will be at its full programmed value and will remain at that value until the Level 1 time is over. Up to 99 Levels of Primary Current and Time for each can be programmed and the System will advance from Level to Level as each Level Time is completed. All Levels do not have to be programmed. When the last level Time (1, 2, 3, 8, 12, etc.) is complete the System will do the following: 12. Sequence Stop: When the last Programmed Level Time is over the System will do the following: Downslope Time: 0 to 99.9 seconds The current will progress to 0 Amperes during this time. When the current is less than 3 Amperes the Arc will go off. Rotation Delay: The Arc will continue to rotate for the same time as the Downslope and Stop rotating the Arc goes out. 13. Post-Purge Time: 0 to 999 Seconds When the Arc goes out the Gas will continue to flow until this programmed time is complete. 14. Return to Home and Reset: When the Post Purge Time is complete the Arc Gas Solenoid will turn off and Model 9 Rotors will Automatically return to the open position for Head removal. The System will reset to be able to repeat the Sequence on the next weld. 2. Operate Lock Mode: When the three-way Keylock is in this position the Selected Weld Schedule cannot be changed. If the key is removed this will prevent anyone from changing the set-up of the System. 3. Weld Programming: The Programming Mode is engaged by the Operating Mode Keylock Switch which can be locked in the Programming position. When engaged in the programming Mode the M-207-1 will perform the following: 1. The display will ask if the user wants to Create a new Weld Schedule, Copy an existing schedule, Modify an existing schedule, Transfer the Weld Schedule Memory to anther M207 or Delete a Weld Schedule. 2. When the above choice is made the display will prompt the Programmer for each step. 3. See the Model 207-1 Operation Manual for further Programming details. Rev. 17 December 2012 Page 7 of 9

11.0 Operation, Modes (continued) 4. Printer SPECIFICATION NO. 207-1 The M-207-1 is supplied Standard with a Printer and Print Select Key. The Printer can issue a copy of the following items: 1. A complete list of all Weld Schedules in memory including Day and Date of print. 2. A complete copy of all Program Parameters for any particular Weld Schedule including Day and Date of print. The System can be set up to issue a copy of this automatically after every weld. 3. A complete copy of all actual Function Values during a Weld including Day and Date of print and a statement as to whether or not the functions performed as programmed. 4. A complete Copy of all Weld numbers contained in the optional M-207- EMM (external Memory Module). 12.0 Additional Standard Features 1. Weld Count: The system will keep track of how many times a particular weld schedule has been used. 2. Tenth Increments: The system can be set up to be able to program Amperes and Weld Level time in increments of 0.1 instead of the standard 1 amp or 1 second. 3. External Sensor Fault: In addition to the built-in Faults (gas, coolant, voltage, etc.) the system can also be set up to accept an Oxygen Analyzer or Temperature Monitor. 4. Speed Math Function: M-9 Heads rotation is entered in RPM. Since the actual welding speed (surface speed) for any given RPM value changes as the weld diameter changes, the system can calculate the required RPM setting for any given weld diameter. By entering the weld O.D. and the desired welding speed, the system will automatically calculate and display the correct RPM setting. 5. Tungsten Length Math Function: Allows the system to calculate required tungsten length. 6. Rotation Calibration: Weld Head contain Tachometers and they must be calibrated to the M-207-1 they are being run on. A built-in Automatic Calibration feature is included in the M-207-1. 7. Remote Equipment Start/Stop - The M-207-1 has Input and Output Connectors to allow for the connection of external devices such as lathes or mills that may need to turn on during the welding sequence. Rev. 17 December 2012 Page 8 of 9

13.0 Options The Model 207-1 can operate a variety of options as follows: 1. Remote Operators Pendant - Option allows the operator to set up, select weld schedule and initiate Weld Sequence from a remote location. 2. M-207-CW Optional Cooling Package - An add-on liquid cooling unit for Weld Heads with duty cycles and weld currents requiring Liquid cooling of the Weld Head or Manual Torch. 3. M-207-EMM External Memory Module - Used to store, transfer or back-up copies of the M-207 memory. 4. Chart Recorder - The M-207-1 is supplied Standard with a Chart Recorder Output Port. When the Optional Chart recorder is connected the user can record the Amperes, Voltage and Travel Speed in continuous Real Time information. 5. Manual Welding Foot Controller - Provides Sequence Start/Stop and variable current. This option is required for manual welding. 6. Manual Welding Torch 7. Extension Cables for Operation of Weld Heads or Manual Torch up to 100 feet from the M-207-1. 8. Conversion to standard M-207 - The Transformer is designed to allow connection to convert back to meet the specifications (150 Ampere) of a standard system. This conversion must be factory installed and the system must be have factory installed and the system must be have factory calibration and certification (QC) performed after the conversion. THIS SPECIFICATION IS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 17 December 2012 Page 9 of 9