Digital Ratio Controller

Similar documents
G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

MICROMASTER Encoder Module

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

CT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions

AF-300 E11 Adjustable Frequency Drive

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

LAUREL ELECTRONICS, INC.

Analogue output module DAO 081

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

K3NX Process Meter OPERATION MANUAL

Process Transmitter RMA 422

DCP100 Digital Control Programmer Specifications

Electrical connection

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Atlas Drop In Decoder

FOREST SHUTTLE S / L / M RECEIVER

USER GUIDE for the. HES92020, HES92021, HES92220 & HES92221 DIMMER Modules

Standard RS232 RS ma

Turnout Decoder TD Maxi. User Manual - version 0.1.6

ARC HEIGHT CONTROL (ARC VOLTAGE CONTROL) MODEL : HAC-01-A-1M

INST No.CP CP Computing unit. Instruction Manual. Important Notice. Keep this manual with due care after understanding operation.

Understanding VFD. Variable Frequency Drive. nfi. nfi

Electronic Lineshaft With Alignment F7 Drive Software Technical Manual

Revision 1.2d

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Quick Operation Guide of LTN7700/7600 Series NVR

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Standard signal metering in wall-mounting case

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Single Axis Position Controller

Transmitter Interface Program

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

TABLE OF CONTENTS. Instructions:

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Operating instructions Electronic preset counter Type series 717

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Electrical connection

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Low-cost labelling system

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

AUTOMATIC VIDEO LOSS A/B SWITCH

Absolute Rotary Encoder E6CP

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346

GAUGEMASTER PRODIGY EXPRESS

Ø50mm Shaft Multi-Turn Absolute Type

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

Label Applicator HERMA 400

APPLICATIONS. Automatic warehouse. Trasportation lines

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

PRINCIPLES AND APPLICATIONS

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

RF Wireless Receiver (Model S4PU-DC-ANT3)

Set Point Controller OC557. Operator s Manual

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

Digital output modules

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Wall-/Pipe-Mount Level Indicator

Absolute Encoders Multiturn

Installing the FOREST SHUTTLE S / L

Process transmitter RMA422

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

DIRECT DRIVE ROTARY TABLES SRT SERIES

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

263 Series LED Bargraph Indicator and Controllers

Series Digital Dimmer. User Manual (VER: 2.0) Net.DO LIGHTING CONTROL EQUIPMENT CO.,LTD

Automatic Transfer Switch Control PLC Operator s Manual

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

HS-509 VIBRATION TRIP MODULE

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Gamma instabus. Technical product information

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

BY 125 Low Cost Synchronous-Controller Operating Instructions for Operator Software OS3.x

Smart-Encoder : Optical Incremental

Pixel LED SPI Digital Controller

Registers type ILR7XX and ILR7XXT

SPECIFICATION NO Model 207 Automatic GTAW Welding System

CDHD Servo Drive. Technical Training Manual. Manual Revision: 2.0 Firmware Version: 1.3.x Software Version: 1.3.x.x

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

ELCOM. Part Application Instruction. Release (V S 0.5) YS Kim S Jeong. OS Program Change to V S1.5 YS Kim S Jeong

Owners SW-LCD 2.0 Manual & Specifications

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Multi-Zone Programmable RGB ColorPlus LED Touch Controller (Remote Control) and RGB ColorPlus LED Touch Controller (Receiver)

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Transcription:

Digital Ratio Controller RSC-406 Control Panel USER S MANUAL RATIO CONTROLLER SPEED RUN PRG ERR RATIO % CH RSC-406

Prelude Thank you for applying our RSC-406 Ratio Controller (abb.406) to you machinery equipment. Since the control systems change quickly with time, previous customers cannot use them until they acquaint all complicate parameters and programs very well. Now we develop the 406 series with strong function and simple operation. Please read this manual before operating 406. Also please keep this manual properly in order to arrange electric wires, set up parameters and trouble-shooting if required in the future. NOTE: (1).Must not arrange the electric wires or unload the connector of 406 when electricity is supplying. (2).Terminals 6~21 are reserved for signals feedback and output, please do not connect with other purposes. (3).Terminals 20(+) and 21(-) must not connect with AC voltage or wrong power source. (4).Please do not take apart the case of controller, and do not test voltage resistance on components of controller inside, either. The parameters of 406 have been set up properly, except on special occasion, please do not re-set them.

Contents 1.Characteristics of RSC-406 Page 3 2. Functions of Control Panel Page 4 3. External Dimensions for Installation. Page 5 4. Standard Connection.. Page 6 5. Connections of Control Loop. Page 7 6. Connections of VR Feedback Control Page 8 7. Connections of Auto/Manual Control Switch Page 9 8. Application of Speed Adjustment.. Page 10 9. Explanations of Terminals.. Page 11 10. Parameter Setting Method Page 13 11. Parameters Table.. Page 14 12. Parameter 01 Programming. Page 15 13. Setting of Ratio K and Speed K Page 16 14. Trouble-shooting.. Page 17 15. Note for Test-Run and Operation. Page 18 Ⅵ.Press or to modify the ratio value, which will show on Green LED of 406 control panel. Ⅶ.States on Test-run. Condition: Parameter 01 is set at 13 1. Normal 2. Starting master motor, but slave motor motionless. Cause: a. Start contacts (Terminals 15 & 16) no short-circuited b. Ratio set 0000 or Ratio K is 0000 c. Channels of Encoder E1 on master motor input contrary If Parameter 01set >8, this supposition is false. d. Signals of Encoder E1 on master motor no connect with Terminals 11 & 12 of 406, meanwhile RUN lamp will be blink. e. Wrong connection on Terminals 20(+) and 21(-) of D/A output, or D/A abnormality. 3. Starting master motor, and slave motor full speed Cause: a. Channels A.B of Encoder E2 on slave motor input contrary. If Parameter 01set >8, this supposition is false. b. Wrong connection of Encoder E2 input on slave motor or E2 abnormality. c. D/A abnormal, and total voltage output DC 10V d. Ratio set too high. 4. Unstable speed of slave motor Modifying Parameter 01 from 0013 to 0009, and test again. If test is O.K., it means the motor torque is insufficient to overcome the moment of inertia. Then modify Parameter 02 to be 40, Parameter 03 to be 20, and time of speed adjustment of inverter to be 2~3 sec. The Contents of this manual may be revised without prior notice. Address comments concerning this manual to: Chih Horng Scientific Co.

15. Note for Test-Run RSC-406 Ⅰ.Please confirm all cable conjunction to be correct first. 1. Power supply must be AC 220V±10% and connect with Terminals 1 & 2 of 406. 2. Channels A.B of Encoder (E1) on master motor, their signals output must connect with Terminals 11 & 12 of 406. 3. Channels A.B of Encoder (E2) on slave motor, their signals output must connect with Terminals 13 & 14 of 406. Please use metal shielded cable for connections of encoders on master (slave) motor. The metal shielded net can connect with Terminal 10 of 406. 4. Terminals 15 & 16 must be short-circuited as serial movement. 5. For parameter modification, Terminals 15 & 16 have to be open-circuited and Terminal 15 & 17 short-circuited. 6. Terminals 20(+) & 21(-) of 406 D/A output have to connect with Analogue cycle command contact of slave motor inverter. The voltage output of Terminal 20 is +0~10 VDC. Ⅱ.Time of speed adjustment of master motor driver should be set > 5 sec. 10 sec. would be better to get good effect. Ⅲ.Time of speed adjustment of slave motor inverter should be set < 0.5 sec. 0.3 sec. would be better to get good effect. If the time of speed adjustment have to be set> 1 sec. for special requirements, please consult our engineer. Ⅳ.Starting frequency of slave motor inverter would be better at 0.3Hz. 1.Characteristics of Control Panel RSC-406 1.This control system can meet with various kinds of DC Drivers, inverters, motor drivers, etc. to make ratio synchronous control. 2.For the accurate speed synchronous control of multi-motors, there is a special design-signal tracing mode which can clearly show the tiny speed change under test-run or operation, in order to select the most suitable parameter for getting the best performance of mechanical operation and design accuracy. 3. 406 has two LED displays (Red and Green) for showing ratio speed and linear speed. 4. 406 is equipped with self-diagnosis, which will find out the abnormal operation and help trouble-shooting. 5.The parameters of 406 can be adjusted according to the requirements of machinery and production, such as the adjustment for different mechanical gear proportion, selection of programming, calculus rate, time of load change and so on. 6. 406 is a closed loop design. It can get an accurate ration synchronous control of multi-motors by input the feedback signals from encoders A.B Channels. This design is also with high interference resistance. 7. 406 has simplified the parameters input. There are only few basic parameters needed to be input, which makes operation simple and more convenient. 8.The self-diagnosis of 406 can detect and correct the connection of encoders A.B channels automatically. It can save the time to reconnect the encoders. Ⅴ.Cable from 406 D/A output to inverter should be metal shielded and isolate from power line. The metal shielded net is connected with 0V contact of signal input of inverter.

2. Functions of Control Panel Green Operation Lamp Yellow Parameter modification Lamp Red Abnormality Lamp RATIO CONTROLLER RUN PRG ERR Parameter selection Button Acceleration Button Addition function: 1. Method for modifying speed: MODE + speed from slow to fast (Acceleration) MODE + speed from fast to slow (Deceleration) 2. Method for moving decimal point: SET + or to move the decimal points of Speed and Ratio. Deceleration Button SPEED RATIO % Parameter input Button Red LED Slave motor speed Green LED Ratio of Master / Slave motor 14. Trouble-Shooting Chart LED Red ERR Lamp RUN Lamp Problem & Cause 0000 Blink Slave motor speed: 0 E1 signal no input 3333 ON Slave motor speed: 0 Signal cables for E1/E2 connected contrary 6666 ON Slave motor speed: 0 A.B channels of signal cable for E1 connected contrary 9999 ON Slave motor speed: 0 A.B channels of signal cable for E2 connected contrary Recovery Check E1 encoder/coupling/ signal cable Re-connect signal cables for E1/E2 Re-connect the A.B channels of signal cable for E1 Re-connect the A.B channels of signal cable for E2 5555 ON Self-diagnosis appears internal abnormality Replace another new RSC-406 controller ON Slave motor full speed 1.Ratio K too high 2.Check encoder E2 3.Check connections 4.Check D/A of controller ON Slave motor speed: 0 Wrong connection between D/A output and Inverter, or Inverter abnormal Slave motor unstable speed, sudden fast and sudden slow Synchronous movement unstable. Ratio value set repeatedly. Check the connection of D/A to Inverter Check Inverter: Default or Abnormality 1. Inverter can t catch up with the fast calculation of 406. Modify Parameter 02 bigger. 2. Time of Speed adjustment of Inverter set improperly. Re-set the time at 0.3 sec. 1. Slip of Encoder and Motor. Check their fixation and coupling. 2. Encoder Signals missing. Check signals per revolution with ordered specification.

13. Setting of Linear Speed Ratio K and Linear Speed K (Values are both set at 1000 by factory) Example: 25M/min 3. External Dimensions for Installation 100m/m RATIO CONTROLLER SPEED A (Master motor) 20M/min 100m/m RUN PRG ERR RATIO % B (Slave motor) Hypothesis: A (Master motor) 25M/min and B (Slave motor) 20M/min are the actual speed How to get the Ratio K : In order to keep up with the actual speed 25M/min, Formula: A/B = 25/20 = 1.25, then Ratio K (Parameter 04) should be set at 1250 to get synchronous movement. How to get the Speed K : The speed displays on LED is 15M/min, which must be modified to 25M/min same as the actual speed, Formula: Actual speed/display speed = 25/15 = 1.666, then the Speed K (Parameter 05) should be set at 1666 to make speed display 25M/min. Press MODE + can accelerate, even on operation. Press MODE + can decelerate, even on operation. 160m/m Panel opening: 92 x 92 m/m 90m/m

4. Standard Connections DC12V E1 E1 E2 E2 TO:INVERTER 100mA D/A (+) (-) A B B A START +10% OUTPUT AC 220V FG ALARM Power source COM PRG -10% R +12V VR input (+) (-) DC IN Preserve 12. Parameter 01 Programming Parameter No. 01 Range Position Trace V/R Input Display Content Self-Diagnosis E1/E2 Channels 0000 NO NO Linear speed NO 0001 NO NO Signal trace NO 0002 NO YES Linear speed NO 0003 NO YES Signal trace NO 0004 YES NO Synchronous linear speed NO 0005 YES NO Synchronous signal trace NO 0006 YES YES Synchronous linear speed NO 0007 YES YES Synchronous signal trace NO 0008 NO NO Linear speed YES 0009 NO NO Signal trace YES 0010 NO YES Linear speed YES 0011 NO YES Signal trace YES 0012 YES NO Synchronous linear speed YES 0013 YES NO Synchronous signal trace YES 0014 YES YES Synchronous linear speed YES 0015 YES YES Synchronous signal trace YES Synchronous signal trace (signal trace) can display the signal difference between E1 and E2. Synchronous linear speed (linear speed) can display the speed or revolution of slave motor. Self-diagnosis E1/E2 channels can detect the A.B channels of encoders E1/E2. It can correct automatically if the connections of channels are reverse. Please note encoders E1 (master motor) and E2 (slave motor) must not be connected reverse.

11. Function: Parameters Table Parameter No. Function Range Factory Setting 01 406 Function 0~15 13 Selection 02 Response time 1~99 10 03 Complementary Time 1~99 1 04 Ratio K 100~9999 1000(100%) 05 Linear Speed K 100~9999 1000(100%) 06 *Additional Voltage per Start 07 Speed Adjustment 0~255 30 0~255 100(10.0%) User Setting Additional Voltage per Start: There will be an additional voltage as start the system. The max additional voltage is 10 VDC divided to 4096 ranks. Each rank is 0.0024 VDC. Factory setting is 30, so additional voltage will be 0.0024 x 30 = 0.072 VDC. 5. Connections of Control Loop Master Encoder 100 P/R Encoder 100 P/R motor VR Speed command for Master motor Inverter for Master motor Shielded cable with 4 cores Shielded cable with 4 cores COM PB1 E1 E2 START PRG PB2 +12V 0V A B B A Inverter for Slave motor General speaking, parameters 01~07 have been set by factory. Except for special requirements, it does not need to modify. 1 2 3 4 5 6 7 8 AC 220V FG Alarm Lamp for Stop machinery as abnormality

7. Connections of VR Feedback Control 10. Parameters Setting Method Example: (1) Modify Parameter 01 (function programming) from 13 to 12. (2) Assure Terminals 15 & 17 are short-circuited, and Terminals 15 & 16 are open-circuited. Master Encoder 100 P/R Encoder 100 P/R motor Step 1. Press MODE button PRG blink 01 Red LED VR Speed command for Master motor Inverter for Master motor Shielded cable with 4 cores Shielded cable with 4 cores COM PB1 Inverter for Slave motor 0013 Green LED Step 2. Press or button to modify value PRG blink 01 Parameter no. 0012 Value (programming) Step 3. Press SET button to confirm the value modification finished. E1 E2 START PRG PB2 +12V 0V A B B A Accomplishing setting, system will return to operation level. If need to modify other parameters, just repeat the procedure above. Press MODE button on and on, the red LED will display from 01~07 in a circle. +12V in 1 2 3 4 5 6 7 8 AC 220V FG Alarm Lamp for Stop machinery as abnormality

Parameter Terminals 15 & 17 are parameters setting. When Setting short-circuited, it is ready for setting or modifying. Please refer to the pages 13 & 14 for the parameters table and their setting method. 7. Connections of Auto/Manual Control Switch Speed Terminals 15 & 18 are ratio acceleration contact A. Adjustment Terminals 15 & 19 are ratio deceleration contact A. Speed rate can be modified on Parameter 07. D/A Output Terminals 20 & 21 are D/A output 0~10V to inverter or DC controller. Please use metal shielded cable and isolate from power lines. Power source (+) and (-) must not be reverse. Master motor Slave motor Inverter for slave motor IN 0V +12V X1 X1 X1 X1 VR manual adjustment

8. Application of Speed Adjustment Upon machinery start, motors will move synchronously. Operator put in cloths (material) which will look like lax. At the time, press button to make Terminals 15 & 18 short-circuited, then the speed of slave motor will suddenly increase 10% (Percentage can be set on Parameter 07). On the contrary, if want to let cloths (material) slacken from a tense state. Press button to make Terminals 15 & 19 short-circuited. Master motor Slave motor Linear speed 10M/min Linear speed 10M/min Cloths input laxly Master motor Slave motor 9. Explanations of Terminals Power source Terminals 1 & 2 are AC power input. Specification: AC 220V ± 10% 50/60 Hz Terminal 3 is F.G. (earth contact) Alarm Terminals 4 & 5 are error output contact A. When the signal difference between E1 and E2 cumulates up to 1000 P/R, Relay output; the difference less than 1000 P/R, Relay no output. Relay capacity: 1A 250 VAC External Terminals 6, 7 & 21 are external ratio control Control input. It is usually variable resistor control. VR resistance 2~5KΩ. Ratio adjustable range 25.5% (±12.7%) COM 15 Terminals 15 & 18 short circuiteded, Accelerate suddenly slave motor can accelerate to O O 18 11M/min, operator check the tension by sight and loosen the Decelerate suddenly button as the proper tension. O O 19 Terminals 15 & 19 short circuiteded, slave motor can decelerate to 9M/min, operator check the tension by sight and loosen the button as the proper tension. E1 and E2 Terminals 9 (+) and 10 (-) are power source of Encoder inputs encoder, DC 12V±3%, 100mA (MAX) Terminals 11 & 12 are signal inputs of encoder on master motor. Terminals 13 & 14 are signal inputs of encoder on slave motor. Start System Terminals 15 & 16 are to start system. It is autocontrol level when short-circuited. Master motor Slave motor