QC External Synchronization (SYN) S32

Similar documents
Major Differences Between the DT9847 Series Modules

MTL Software. Overview

Getting Started with the LabVIEW Sound and Vibration Toolkit

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

Using the BHM binaural head microphone

A New "Duration-Adapted TR" Waveform Capture Method Eliminates Severe Limitations

Building Video and Audio Test Systems. NI Technical Symposium 2008

News from Rohde&Schwarz Number 195 (2008/I)

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

3G/HD/SD dual channel audio embedder/de-embedder

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

ex 800 Series ematrix System

Pre-processing of revolution speed data in ArtemiS SUITE 1

C8000. switch over & ducking

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

Revision History. SDG2000X Firmware Revision History and Update Instructions

Broadcast Television Measurements

Next Generation Software Solution for Sound Engineering

USER GUIDE FOR NETmc MARINE X-Ops

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

THE LXI IVI PROGRAMMING MODEL FOR SYNCHRONIZATION AND TRIGGERING

TF5 / TF3 / TF1 DIGITAL MIXING CONSOLE. TF Editor User Guide

OptoFidelity Video Multimeter User Manual Version 2017Q1.0

Radio for Everyone...

4 MHz Lock-In Amplifier

MULTIMIX 8/4 DIGITAL AUDIO-PROCESSING

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

The high-end network analyzers from Rohde & Schwarz now include an option for pulse profile measurements plus, the new R&S ZVA 40 covers the

RECOMMENDATION ITU-R BT (Questions ITU-R 25/11, ITU-R 60/11 and ITU-R 61/11)

Syrah. Flux All 1rights reserved

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV

Supervision of Analogue Signal Paths in Legacy Media Migration Processes using Digital Signal Processing

Product Information. EIB 700 Series External Interface Box

4T2 Portable. digital broadcast measurement receiver. Advanced Broadcast Components Ltd. Wacholderstrasse Bad Segeberg

Logic Analysis Basics

AcoustiSoft RPlusD ver

AWS-750. Anycast Touch portable live content producer. Overview

DIGITAL MIXING CONSOLE. TF Editor V3.6 User's Guide

Logic Analysis Basics

ExtIO Plugin User Guide

Mobile DTV Viewer. User Manual. Mobile DTV ATSC-M/H DVB-H 1Seg. Digital TV ATSC DVB-T, DVB-T2 ISDB-T V 4. decontis GmbH Sachsenstr.

rega ITE audifon GmbH & Co. KG Werner-von-Siemens-Straße 2 D Kölleda Tel Fax

Measuring Delays. A Step by Step instruction. (c) 2017 by Thomas Neumann

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

Calibrate, Characterize and Emulate Systems Using RFXpress in AWG Series

Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

AN4184 Application note

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

PulseCounter Neutron & Gamma Spectrometry Software Manual

Lab 1 Introduction to the Software Development Environment and Signal Sampling

Agilent Technologies Pulse Pattern and Data Generators Digital Stimulus Solutions

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels

CBF500 High resolution Streak camera

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual

quantumdata 980 Series Test Systems Overview of UHD and HDR Support

980 Protocol Analyzer General Presentation. Quantum Data Inc Big Timber Road Elgin, IL USA Phone: (847)

Oscilloscopes, logic analyzers ScopeLogicDAQ

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

MODEL 5493A DTMF MODEM

Oculomatic Pro. Setup and User Guide. 4/19/ rev

USER S GUIDE DSR-1 DE-ESSER. Plug-in for Mackie Digital Mixers

SigPlay User s Guide

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

FS3. Quick Start Guide. Overview. FS3 Control

Agilent Parallel Bit Error Ratio Tester. System Setup Examples

013-RD

E4416A EPM-P Series Single Channel Power Meter

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

DNT0212 Network Processor

RF (Wireless) Fundamentals 1- Day Seminar

Signal Stability Analyser

Model 7130 HD Downconverter and Distribution Amplifier Data Pack

Correlated Receiver Diversity Simulations with R&S SFU

Label Applicator HERMA 400

Video VBOX Pro RLVD10P2P/RLVD10P2PV/RLVD10P4PV/RLVD20P2PV/RLVD20P4PV. Features

Natural Radio. News, Comments and Letters About Natural Radio January 2003 Copyright 2003 by Mark S. Karney

Maintenance/ Discontinued

AT70XUSB. Digital Video Interfacing Products

DNT0212 Network Processor

Video VBOX Waterproof

SC26 Magnetic Field Cancelling System

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

DW Drum Enhancer. User Manual Version 1.

Video Analyzer UAF. Perfection in video analysis

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

TV Synchronism Generation with PIC Microcontroller

Technical data. General specifications. Indicators/operating means

Advanced Test Equipment Rentals ATEC (2832)

TSG 90 PATHFINDER NTSC Signal Generator

Performing a Sound Level Measurement

R&S EDS300 DME/Pulse Analyzer Specifications

Transcription:

Frequence sponse KLIPPEL Frequence sponse KLIPPEL QC External Synchronization (SYN) S32 Module of the KLIPPEL ANALYZER SYSTEM (QC Version 6.1, db-lab 210) Document vision 1.2 FEATURES On-line detection and compensation delays in the measurement chain (e.g. due to 3rd party audio devices) Trigger measurement with incoming synchronization signal Fast and robust synchronization Integration in Klippel QC Tolerant towards for sample rate deviation Tolerant towards multi-way sound propagations (e.g. reflections) Fast setup Customizable sync requests in a task BENEFITS Cope with varying delays in openloop setups (e.g. Bluetooth) Use autonomous playback/recording devices Independent of signal amplitude Electric or acoustical measurement channels Test devices with dedicated audio device Test devices with unknown delay (e.g. 3 rd party audio devices, USB speaker, Bluetooth devices) Ultra-fast testing despite unknown delays DESCRIPTION The External Synchronization (SYN) is an add-on to the QC framework of the Klippel Analyzer System. The module can be applied with all QC measurement tasks for easy setup and handling via the standard user interface. Furthermore, stand-alone devices (e.g. CD/mp3- Player or tablet computers) with autonomous playback can trigger the analysis by playing back the sync signal. Synchronization through the measurement channel allows on-line detection and compensation of varying delays in the measurement chain (e.g. Bluetooth/USB speaker). refger refger Applications: USB/Bluetooth/digital speakers Headphones Media players (CD, mp3/ogg/flac/, mobile phones, tablets) Dictaphones Automobile audio systems Article number 1001-107

QC External Synchronization (SYN) 1 Overview S32 CONTENT 1 Overview... 2 2 Examples... 3 3 quirements... 5 4 Parameters... 6 5 sults... 7 1 Overview 1.1 Summary 1.2 Principle The External Synchronization (SYN) provides synchronization through the measurement channel. A synchronization signal (trigger) is detected in the incoming data stream (e.g. signal captured by the microphone). Subsequent measurements and analyses are triggered at the correct points of time. This technique is necessary to perform high-speed measurements by providing synchronous excitation and analysis for audio devices with unknown or variable delay (e.g. Bluetooth speaker) or audio devices that do not provide an accessible signal input (e.g. tablet computer or media player without AUX input). The External Synchronization uses a linear modeling technique (impulse response) to detect a synchronization signal in the incoming data stream. The analysis is performed block-wise and the crest factor of each block s impulse response is evaluated to find a valid synchronization. 1.3 Activation and Execution Mode Selection The External Synchronization can be activated in Control:Start for each QC test. The defined execution mode applies to the complete test. SYN Dynamic SYN Static modes See application examples USB speaker and Bluetooth speaker below. The dynamic execution mode allows synchronizing through the measurement channel, while keeping the test dynamical. This mode is usually applied for devices under test with unknown/changing delay with available signal input and output streams. See application example Automobile audio system below. The static execution modes (Capture, Playback, Export and Import) use either the internal signal generator or the internal data acquisition. Arbitrary definable synchronization requests ( trigger points ) allow a flexible triggering of the analysis at the correct point of time. KLIPPEL Analyzer System Page 2 of 7

Start analysis task 1 QC External Synchronization (SYN) 2 Examples S32 Task 1 Task 2 t.. point of time T.. duration Sync (Tsync1) DelayBefore (Tdb1) Sweep (Tsw1) DelayAfter (Tda1) DelayBefore (Tdb2) Sweep (Tsw2) Sync found tsync1 time ttask1 = tsync1 + Tsync1 + Tdb1 Start analysis task 2 ttask2 = ttask1 + Tsw1 + Tda1 + Tdb2 Synchronization quests This execution mode is usually applied for devices with inaccessible signal input. For media players the is exported and copied to the device s storage. The playback of the stimulus is completely asynchronous to the analysis in that case. The timing of the complete must be defined before the measurement. If a SYN execution mode is active, every compatible measurement task may define synchronization requests, which starts a synchronization search in the input signal before the measurement. Several request templates provide a flexible, yet easy configuration. 2 Examples 2.1 USB Speaker Frequence sponse K LIP PE L USB Multimedia Speaker Mic The stimulus is played back with a 3rd party audio device (USB audio device) with unknown delay. The synchronization is performed dynamically through the acoustical measurement channel. Subsequent measurements use the detected delay to trigger the analysis in the quasi-synchronous playback process. For test signal playback, the speaker audio device is directly used as output sound device. Optionally, additional hardware like 2 nd microphone, temperature/humidity sensor, footswitch, etc. may be used. KLIPPEL Analyzer System Page 3 of 7

K LIP PE L QC External Synchronization (SYN) 2 Examples S32 2.2 Bluetooth Speaker Frequence sponse refger 2.3 Automobile audio system This setup is similar to the USB speaker example above, but the test signals are transferred wirelessly via Bluetooth. Stimulus Stimulus Exported WAVE file Frequence sponse K LIP PE L Microphone If the device under test (in this example an automobile audio system) does not provide an accessible auxiliary signal input, the stimulus must be transferred offline to the audio system. This requires fixed timing modes by using static delays between the measurements. The stimulus is generated and exported by the QC system and copied to a suitable medium (e.g. CD or memory card). The playback is performed autonomously by the device under test. The playback of the sync signal triggers the analysis at the correct point of time. KLIPPEL Analyzer System Page 4 of 7

REC QC External Synchronization (SYN) 3 quirements S32 2.4 Handheld cording Device Stimulus Frequence sponse K LIP PE L corded response 3 quirements 3.1 Hardware 3.2 Software 3.3 License For measurements with handheld recording devices that do not provide a signal output or are used for mobile recordings distant from the analyzing system the measured response shall be analyzed offline. While recording, the microphone signal is stored in the device s memory. The audio file is imported by the QC software for analysis. Note: The stimulus may be exported to a WAVE file or directly played back. No additional hardware is needed. The SYN applies to QC operations only and is available for Klippel QC version 4 or later or db-lab QC in R&D framework from version 210. The activation and selection execution mode is available in the Control:Start task. The following tasks are able to request synchronization: Sound Pressure (SPL) Air Leak Detection (ALD) Coherence Equalization & Alignment (EQA) Multitone Distortion (MTD) Signal Test A license and a USB license dongle are required to activate the SYN. KLIPPEL Analyzer System Page 5 of 7

QC External Synchronization (SYN) 4 Parameters S32 4 Parameters CATEGORY EXECUTION (CONTROL:START) Parameter Description Available feature options External Synchronization Allows the selecting a SYN execution mode to define synchronization requests SYN: dynamic (Playback + Capture) SYN: static Capture (+Export) SYN: static Import (+Playback) CATEGORY EXECUTION (MEASUREMENT TASKS) External Synchronization quest and parameterize the synchronization performed before the measurement. *Custom parameters (available for custom synchronization requests) No synchronization request Template: sync2stimulus (stimulus, with 50% repetition) Template: low-frequency DUT (2 s pink noise sync signal) Template: mid-frequency DUT (0.5 s pink noise signal) Template: high-frequency DUT (0.1 s white noise signal) Custom (enables custom parameters *) *Sync quest *ID (only for pink/white noise) *Sample rate tolerance *Crest limit *Level (only for pink/white noise) Defines the synchronization signal type Unique identifier for noise synchronization signals Activates sample rate tolerance for the synchronization. For sync2stim, the end of the stimulus is repeated. If the sample rate tolerance is active, synchronization a sample rate deviation of +/- 10% is detected. crest factor limit of impulse response for a valid synchronization peak level ratio of synchronization signal and measurement stimulus Min Default Max Unit Sync2Stimulus Pink noise sync signal White noise sync signal 1 taskid 1e5 off on 10 25 db -3 0 db *Time (only for pink/white noise) Duration of synchronization signal 0.1 0.5 5 s Max. Sync Tries High pass *Input routing Number of synchronization tries. Only available in dynamic mode. High pass for synchronization process Input routing for synchronization process 1 3 Same as measurement Mic1 Line1 Mic2 Line2 200 Hz KLIPPEL Analyzer System Page 6 of 7

QC External Synchronization (SYN) 5 sults S32 *Output routing Output routing for synchronization Same as measurement *Expert parameters Activation of expert parameters to allow fine tuning of synchronization and processing * only visible with a custom synchronization request Out 1 Out 2 Out 1 + 2 ExtSync.MaxTol (maximum tolerance in db to force selecting the incidence of direct sound, typically -3.. -6 db) ExtSync.AnaSyncRatio (ratio analysis block size to synchronization signal duration, typically 1.5.. 3) ExtSync.Timeout (timeout for synchronization, typically 5.. 60 s) ExtSync.SrtRatio (ratio of repeated part to complete stimulus, typically 0.1.. 0.9) ExtSync.WaitBeforeSync (time in seconds the sync search is delayed) 5 sults The main benefit of the SYN module is the triggering of analysis on the correct point of time. Beside the alignment of analysis and measurement several parameters are available in the HTML and Log output. Parameter SYN Delay SYN Crest Factor SYN Sample rate factor Description Detected delay between playback and capture process. This is the delay that is compensated in subsequent measurements. Detected crest factor of successful synchronization Detected sample rate deviation between capture and playback processes. Find explanations for symbols at: http://www.klippel.de/know-how/literature.html Last updated: July 09, 2018 KLIPPEL Analyzer System Page 7 of 7