Observation of vacuum arc cathode spot with high speed framing camera

Similar documents
CBF500 High resolution Streak camera

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Thyratrons. High Energy Switches. Features. Description

Large Area, High Speed Photo-detectors Readout

An RF Excited Plasma Cathode Electron Beam Gun Design

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

KLYSTRON GUN ARCING AND MODULATOR PROTECTION

ELECTRON OPTICS OF ST-X, ST-Y SERIES OF STREAK & FRAMING CAMERA TUBES

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

4.9 BEAM BLANKING AND PULSING OPTIONS

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

RECENT PROGRESS IN UPGRADE OF THE HIGH INTENSITY THzzz zz-fel AT OzSAKzA UNIVERSITYzzzz

Detailed Design Report

vacuum analysis surface science plasma diagnostics gas analysis

Uniformity of Plasma Density and Film Thickness of Coatings Deposited Inside a Cylindrical Tube by Radio Frequency Sputtering

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

STUDIES OF ENHANCED EDGE EMISSION OF A LARGE AREA CATHODE *

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

Closed Cycle Cryogenic Probe Station

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

Cathode Spot Movement in Vacuum Arc Using Silicon Cathode

Physics of high-current diode

Generation of Novel Waveforms Using PSPL Pulse Generators

This work was supported by FINEP (Research and Projects Financing) under contract

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

The extremely compact laser head is approximately 480 mm long and can

4. ANALOG TV SIGNALS MEASUREMENT

GFT Channel Digital Delay Generator

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

Operating Instructions for PMT Tube P3

The hybrid photon detectors for the LHCb-RICH counters

Screen investigations for low energetic electron beams at PITZ

2x1 prototype plasma-electrode Pockels cell (PEPC) for the National Ignition Facility

HIGH VOLTAGE DISCHARGES AS ELECTRON BEAM SOURCE FOR CALIBRATION MEASUREMENTS UDC: M. Magureanu, N. B. Mandache

A New 4MW LHCD System for EAST

Investigation of Radio Frequency Breakdown in Fusion Experiments

Computational Studies of X-ray Framing Cameras for the National Ignition Facility

THE CARE AND FEEDING OF CROWBAR THYRATRONS

Applications. l Image input devices l Optical sensing devices

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

Large-Scale Polysilicon Surface Micro-Machined Spatial Light Modulator

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

CCD220 Back Illuminated L3Vision Sensor Electron Multiplying Adaptive Optics CCD

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

RF Power Generation II

INSTRUMENT CATHODE-RAY TUBE

HIGH VOLTAGE SWITCH PERFORMANCE OF THE EIMAC X-2159 TETRODE ABSTRACT

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Impact of DMD-SLMs errors on reconstructed Fourier holograms quality

w. R. Scarlett, K. R. Andrews, H. Jansen

Universal streak camera C10910 series

GFT Channel Slave Generator

Elements of a Television System

RADIOGRAPHIC PERFORMANCE OF CYGNUS 1 AND THE FEBETRON 705

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Advanced Test Equipment Rentals ATEC (2832)

NEW ACHIEVEMENTS IN THE FIELD OF DEVELOPMENT OF MOBILE X-RAY TV- SYSTEM

Reprint of Poster Presentation EML, May Welleman, E. Ramezani, J. Walmeyer, S. Gekenidis

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

DPD80 Infrared Datasheet

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Wavelength selective electro-optic flip-flop

These are used for producing a narrow and sharply focus beam of electrons.

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

RF Solutions for Science.

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

Performance Characteristics of Steady-State MPD Thrusters with Permanent Magnets and Multi Hollow Cathodes for Manned Mars Exploration

CATHODE-RAY OSCILLOSCOPE (CRO)

TIL311 HEXADECIMAL DISPLAY WITH LOGIC

Agilent Technologies 54522A

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR

PULSE & DELAY GENERATOR. Output Amplitude HIGH SPEED DIGITIZER. BW / max. Sample Rate STREAK CAMERA

LED Display Product Data Sheet LTP-1557TBE Spec No.: DS Effective Date: 06/16/2010 LITE-ON DCC RELEASE

Physics Requirements for the CXI Ion Time-of-Flight

ECB DIGITAL ELECTRONICS PROJECT BASED LEARNING PROJECT REPORT ON 7 SEGMENT DIGITAL STOP WATCH USING DECODER

Trigger-timing signal distribution system for the KEK electron/positron injector linac

3B SCIENTIFIC PHYSICS

SINGLE DIGIT LED DISPLAY (0.50 Inch) LSD505/61-XX DATA SHEET

HY-32 Deuterium Triode Thyratron

Experimental Astrophysics Group, Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

Camera Interface Guide

TESLA FEL-Report

Design Studies For The LCLS 120 Hz RF Gun Injector

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1210

Development of high power gyrotron and EC technologies for ITER

Chapter 2 Circuits and Drives for Liquid Crystal Devices

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

LM MHz RGB Video Amplifier System with OSD

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

Transcription:

Observation of vacuum arc cathode spot with high speed framing camera Maxim B. Bochkarev* a, Vitaly B. Lebedev b, Gregory G. Feldman b a Institute of Electrophysics, Amundsena Str. 106, 620016 Ekaterinburg, Russia; b BIFO Company, Ozernaya 46, 119361, Moscow, Russia ABSTRACT A copper vacuum arc cathode spot at current 10-100 A was imaged by three-frame camera K 001 1 (BIFO Company, Russia) with frame exposures 30 ns and 6 ns and spatial resolution up to 7 µm. It was found that spot splitting into separate fragments occurs at currents higher than 50 A. The average fragment size was found to be 20 µm at current about 10 A (cathode spot consists of a single fragment). With the rise of the arc current the average fragment size rises too and reaches 50 µm at current 100 A (cathode spot consists of two or three fragments). The overall dimension of region occupied by cathode spot fragments rises from 20 µm at current 12 A to 120 µm at current 100 A. Observations with high temporal resolution (exposure time 6 ns) reveal the significant changes of cathode spot brightness occurring within about 10 ns time interval. Keywords: cathode spot, ecton, vacuum arc, framing camera 1. INTRODUCTION Vacuum arc current at the cathode passes through tiny luminous objects less than 100 µm in diameter called cathode spots. The cathode spots chaotically move over the surface and provide both the electrons for current flow and the medium (ions, plasma) to account for negative space charge of electrons, thus resulting in high current and low voltage (about 20 V for copper) vacuum discharge. The cathode processes of plasma injection are highly non-stationary and the instabilities of the current, voltage, radiation, plasma and ion flows are the main features of vacuum arc discharge 2,3. The vacuum arc cathode spot structure and dynamics has been thoroughly investigated last years with high speed imaging techniques 4,5,6,7,8. It was found that high speed images reveal the cathode spot internal structure, it consists of fragments of size from few microns to tens microns and carrying a current of few Amps and up to tens Amps. These fragments are highly non-stationary and appear and disappear within few nanoseconds or tens of nanoseconds. Such a behavior has its natural explanation within the ecton model of cathode spot operation 9,10. The model presumes that the basic process of the cathode spot fragment is an ecton the explosion of cathode metal micro-volume that produce plasma for current flow through the discharge. Meanwhile no investigations were made on the dependence of cathode spot structure on arc current. The aim of present work is to perform measurements of the number of fragments within the cathode spot as a function of arc current. 2. EXPERIMENTAL SET UP AND PROSEDURE Experiments were made in stainless steel vacuum chamber evacuated to 10-8 torr by oil-free pumping system. The bandwidth of the chamber is about 1 GHz. The view of the electrode system is shown in Fig.1. The cathode spot was ignited on the lateral side of the cathode by auxiliary trigger pin electrode made of tungsten with the tip of 20 µm. Cathode was a 3 mm long piece of OFHC copper wire of diameter 300 µm at the tip, the anode was a tungsten wire 200 µm of diameter. Anode to cathode distance was 150-200 µm. Before the measurements the cathode surface was cleaned by multiple arcing with current 20 A rms and pulse duration 100 µs, for it is known 11 that the arc itself is reliable technique to remove surface contaminations. The electrical circuit diagram of arc power supply and measurements is maxim@iep.uran.ru; phone 7 343 267 87 81, fax 7 343 267 87 94; www.iep.uran.ru 27th International Congress on High-Speed Photography and Photonics, edited by Xun Hou, Wei Zhao, Baoli Yao, Proc. of SPIE Vol. 6279, 62792E, (2007) 0277-786X/07/$15 doi: 10.1117/12.725236 Proc. of SPIE Vol. 6279 62792E-1

Fig.1. View of electrode system. I cathode Discharge power supply Us RCH RL/M : : C Vacuum chamber ::c-r R-: ' High voltage pulser 20 kv, 40 ns, 75 Ohm C - Cathode Shunt T- Trigger Fig.2. Electrical scheme of measurements and discharge power supply. Arc current 1 to osc. 50 Ohm 1 sf frame 2nd frame 3rd frame a b Fig.3. Lower trace- arc current. Upper trace camera trigger pulse; a -time 200 ns/div, current - 30 A/div. b time 100 ns/div, current 6 A/div. given in Fig.2. High voltage pulse generator (HVPG) is based on co-axial cables of 75 Ω impedance, pulse amplitude is 15 20 kv. HVPG produces two pulses simultaneously, one for arc ignition (duration 40 ns, current 4 A) and another for framing camera triggering. For currents 30 100 A the main discharge was fed by low inductance RC- circuit (R 10 Ω, C 0,1 µf) connected to the anode, initially the capacitor was charged to a dc voltage, thus the discharge current was decreasing. The discharge duration was 1 2 µs depending on dc charging level. For currents 10-30 A we used a piece Proc. of SPIE Vol. 6279 62792E-2

KOOl STREAK &3 FRAME CAMERA MICROSCOPE DISCHARGE CHAMBER Fig.4. Scheme of optical measurements ARC IGNITION PULSE GERIN NIGH VOLTAGE POWER SUPPLY rigger OUT U. Fig.5. Experimental arrangement. of coaxial cable of 75 Ω impedance and electrical length 350 ns instead of RC-circuit. The arc current was measured by 0.34 Ω resistor in the cathode circuit by using the Tektronix 684B digital oscilloscope that has 1 GHz bandwidth and up to 5 Ghz sampling rate. An example of the arc current waveforms is given in Fig.3, the pulse that triggers the K001 camera is also shown. All experiments were performed at fixed delay of camera trigger to arc ignition, and it was set to 300 ns. The scheme of optical measurements is shown in Fig.4. Cathode spot was observed end on through the glass window and photo-port of Stemi 2000C Carl Zeiss stereomicroscope (glass optics) by using K001 1 universal image converter camera. This camera operates in spectral range of 380 800 nm and has a several picosecond limiting temporal resolution in streak mode and near 4GHz maximum frame repetition rate with 160 ps frame duration in threeframing mode. Figure 5 represents the view of the experimental arrangement. Microscope has a numerical aperture N.A.= 0,085 and theoretical spatial resolution of magnifying optics at 400 nm wavelength is 2,9 µm. The spatial resolution at the photocathode of K001 camera in framing mode is 3 pl/mm that means approx. 7 µm spatial resolution in the object plane at our magnification, magnification was 23 times and 1 µm in object plane corresponds to 1 pixel of the final image. We used two regimes of camera in framing mode (Table 1). Table 1. Camera regimes used in the experiment Exposure Interframe period Dark time time Delay from the trigger pulse to the start of the first frame 30 ns 77 ns 47 ns 190 ns 6 ns 11,35 ns 5,35 ns 85 ns Proc. of SPIE Vol. 6279 62792E-3

1oo a b c Fig.6. Frame sequences from top to bottom; a 17 A, b- 34 A, c - 50 A. Exposure time 30 ns. a b c Fig.7. Frame sequences from top to bottom; a 50 A, b- 75 A, c - 100 A. Exposure time 30 ns. 3. RESULTS AND DISCUSSION Due to the lack of light intensity we were able to start measurements from current level 10 A. From this current and up to 50 A the cathode spot consists of only single fragment. An example of frame sequence with exposure 30 ns at currents 17 A, 34 A and 50 A is shown in Fig. 6. At current 50 A the elongation of cathode spot could be seen, while no division into fragments occurs. Nevertheless, sometimes at current 50 A cathode spot division is observable. Figure 7 represents the cathode spot division into two or, as in the case of Fig.7c, presumably into three fragments. We have never seen three distinctly separated fragments in our experiments. This finding contradicts to available literature data when authors 4,5,6 agree that at currents 60 80 A cathode spot has 4-6 separate fragments carrying a current approximately 10 A each. The possible explanation is that authors mentioned above carried measurements after tens microseconds after the arc ignition, in our case the time elapsed from arc ignition is approx. 500 ns and the cathode processes is not steadied yet. Proc. of SPIE Vol. 6279 62792E-4

100 jn a b c Fig.8. Frame sequences from top to bottom; a 50 A, b- 100 A, c - 100 A. Exposure time 6 ns. =. n Cu, > 1 =. = luminosity dimension, pm = = = = = Fig.9. Overall spot dimensions (solid line) and the size of individual fragments of which the spot consists (dashed line) as a function of arc current. Data for exposure time 30 ns. Observations with higher temporal resolution (exposure time 6 ns) reveal the spot brightness fluctuations occurring in 10 ns time scale (inter-frame period 11,35 ns) that illustrated in Fig.8. for currents 50 and 100 A. For lower currents the luminosity of spot is too weak to be observable at such short an exposure. In general our observations confirm the literature data concerning luminosity dynamics of cathode spot and fragments, namely the changes of luminosity occur on tens nanosecond time scale and the appearance and disappearance of cathode spot fragments can occur within 10 ns time interval. Finally, the Fig.9 represents the results of measurements with the exposure time 30 ns of overall spot Proc. of SPIE Vol. 6279 62792E-5

dimensions (solid line) and the size of individual fragments of which the spot consists as a function of arc current. The dimensions of the luminous objects were measured as full width at half maximum of luminosity profiles.. 4. CONCLUSIONS It was found that spot splitting into separate fragments occurs at currents higher than 50 A. The average fragment size was found to be 20 µm at current about 10 A (cathode spot consists of a single fragment). With the rise of the arc current the average fragment size rises too and reaches 50 µm at current 100 A (cathode spot consists of two or three fragments). The overall dimension of region occupied by cathode spot fragments rises from 20 µm at current 12 A to 120 µm at current 100A. ACKNOWLEDGEMENTS This work was supported by Russian Fundamental Research Foundation under Award 05 02 17612. REFERENCES 1. K001 streak & 3-frame camera, http//www.bifocompany.com 2. L. P. Harris, Arc cathode phenomena, in Vacuum Arcs, J. M. Lafferty, Ed. New York: Wiley, 1980. 3. B. Juttner, V. F. Puchkarev, "Cathode spots. Phenomenology", in "Handbook of Vacuum Arc Science and Technology", R. L. Boxman, P. J. Martin and D. M. Sanders, Eds. Park Ridge, NJ: Noyes, 1995. 4. B. Juttner, The dynamics of arc cathode spots in vacuum, Journ. Phys. D: Appl. Phys., 28, 516-522, 1995. 5. P. Siemroth, T. Schulke and T. Witke, Investigation of cathode spots and plasma formation of vacuum arc by high speed microscopy and spectroscopy, IEEE Trans. Plasma Sci., 25(4), 571 579.,1997. 6. B. Juttner, The dynamics of arc cathode spots in vacuum: new measurements, Journ. Phys. D: Appl. Phys., 30, 221-229, 1997. 7. B. Juttner, The dynamics of arc cathode spots in vacuum. Part III: measurements with improved resolution and UV radiation, Journ. Phys. D: Appl. Phys., 31, 1728-1736, 1998. 8. A. Anders, S. Anders, B.Juttner and B. Pursch, Vacuum arc cathode spot parameters from high-resolution luminosity measurements, J. Appl. Phys. 71 (10), 4763-4770 (1992). 9. G.A. Mesyats, Ecton mechanism of the vacuum arc cathode spot, IEEE Trans. Plasma Sci., 23(6), 879 883, 1995. 10. S.A. Barengolts, G.A. Mesyats, and D.L. Shmelev, Structure and time behavior of vacuum arc cathode spots, IEEE Trans. Plasma Sci., 31(5), 809 816, 2003. 11. J. Achtert et al., Influence of surface contamination on cathode processes of vacuum discharges, Beitr. Plasma Phys., 17, 419-431, 1977. Proc. of SPIE Vol. 6279 62792E-6