G0 Laser Status Parity Controls Injector Diagnostics

Similar documents
Status of the Jefferson Lab Polarized Beam Physics Program and Preparations for Upcoming Parity Experiments

Polarized Source Development Run Results

Parity Quality Beam (PQB) Study

Photoinjector Laser Operation and Cathode Performance

POLARIZED LIGHT SOURCES FOR PHOTOCATHODE ELECTRON GUNS AT SLAC?

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

The FLASH objective: SASE between 60 and 13 nm

Photo cathode RF gun -

RF considerations for SwissFEL

Hall-B Beamline Commissioning Plan for CLAS12

KARA and FLUTE RF Overview/status

DAQ Systems in Hall A

Digital BPMs and Orbit Feedback Systems

P. Emma, et al. LCLS Operations Lectures

Current status of XFEL/SPring-8 project and SCSS test accelerator

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

Linac 4 Instrumentation K.Hanke CERN

Simulations on Beam Monitor Systems for Longitudinal Feedback Schemes at FLASH.

Drive Laser Operations

The Elettra Storage Ring and Top-Up Operation

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

Summary of the 1 st Beam Line Review Meeting Injector ( )

5 MeV Mott Polarization Measurement Procedure--DRAFT

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

4.4 Injector Linear Accelerator

First Simultaneous Top-up Operation of Three Different Rings in KEK Injector Linac

LHC Beam Instrumentation Further Discussion

GFT Channel Digital Delay Generator

Screen investigations for low energetic electron beams at PITZ

PQB Meeting. Caryn Palatchi 02/15/2018

PEP II Design Outline

Design Studies For The LCLS 120 Hz RF Gun Injector

Future Performance of the LCLS

Status of the X-ray FEL control system at SPring-8

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

Fast Orbit Feedback at the SLS. Outline

Precision measurements of beam current, position and phase for an e+e- linear collider

Upgrading LHC Luminosity

Recent APS Storage Ring Instrumentation Developments. Glenn Decker Advanced Photon Source Beam Diagnostics March 1, 2010

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

Beam Instrumentation for X-ray FELs

Status of SOLARIS. Paweł Borowiec On behalf of Solaris Team

Suppression of Timing drift between laser and electron beam driven photo-cathode RF gun

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

An Operational Diagnostic Complement for Positrons at CEBAF/JLab

Accelerator Instrumentation RD. Monday, July 14, 2003 Marc Ross

Development of BPM Electronics at the JLAB FEL

Summary of recent photocathode studies

ModBox-1310nm-1550nm-NRZ 1310nm & 1550 nm, 28 Gb/s, 44 Gb/s Reference Transmitters

Update on DAQ for 12 GeV Hall C. Brad Sawatzky

CHEETAH-X Compact Picosecond Laser. Customized systems with SESAM technology*

Beam Position Monitor Developments at PSI

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

Beam Losses During LCLS Injector Phase-1 1 Operation

System: status and evolution. Javier Serrano

40-Meter Subsystems: As LIGO-Like as Possible

Activities on FEL Development and Application at Kyoto University

Operational experience with the SOLEIL LINAC and Status of the ThomX LINAC project

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

Soft x-ray optical diagnostics, concepts and issues for NGLS

Present Status and Future Upgrade of KEKB Injector Linac

Beamline improvement during g2p experiment. Pengjia Zhu

ModBox-1310nm-1550nm-28Gbaud-PAM nm & 1550 nm, 28 Gbaud PAM-4 Reference Transmitter

The PEFP 20-MeV Proton Linear Accelerator

ModBox-CBand-NRZ series C-Band, 28 Gb/s, 44 Gb/s, 50 Gb/s Reference Transmitters

Update on DAQ for 12 GeV Hall C

Sérgio Rodrigo Marques

Status of SOLARIS Arkadiusz Kisiel

Cathode Studies at FLASH: CW and Pulsed QE measurements

Status of CTF3. G.Geschonke CERN, AB

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

Compact, e-beam based mm-and THzwave light sources

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

GFT Channel Slave Generator

CLIC Feasibility Demonstration at CTF3

NSLS-II RF Systems James Rose, Radio Frequency Group Leader PAC 2011

30 GHz Power Production / Beam Line

LCLS-II Injector Tuning Procedures. F. Zhou (SLAC) & F. Sannibale (LBNL) 2/6/2017

North Damping Ring RF

ModBox-850nm-NRZ-series

Detailed Design Report

AREAL- Phase 1. B. Grigoryan on behalf of AREAL team

RX40_V1_0 Measurement Report F.Faccio

FEL TEST PLAN WORKSHEET

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Implementation of the feed forward correction for the FLASH photo injector laser and future plans for a feedback system

Status of KEK X-band Test Facility and its future plans

Capability Improvements: Polarized Photoinjector*

Status of RF Power and Acceleration of the MAX IV - LINAC

Intra-train Longitudinal Feedback for Beam Stabilization at FLASH

TLB-2020-L. Full L Band Tunable CW Laser. 20 mw Full Band Tunable CW Laser Butterfly. Features. Applications. Benefits

BCM Calibration for E Abstract

Trigger-timing signal distribution system for the KEK electron/positron injector linac

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

SC24 Magnetic Field Cancelling System

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Operation of CEBAF photoguns at average beam current > 1 ma

Commissioning and Initial Performance of the Belle II itop PID Subdetector

DVO700 P FIBRE OPTIC TRANSMITTER

Transcription:

G0 Laser Status Parity Controls Injector Diagnostics G0 Collaboration Mtg Jefferson Lab August 16, 2002 G0 Collaboration Mtg (August 16, 2002), 1

Installed new AOM homebuilt laser G0 Collaboration Mtg (August 16, 2002), 2

Homebuilt laser results Reminder: the new AOM provides better pulse-picking, i.e., better extinction ratio for mode-locking. Found that by using a cleaner RF source the optical pulses shortened from ~260 ps to about ~ 180 ps fwhm. Installed the improved homebuilt G0 laser with new AOM and better RF source on August 8th. The new optical pulse-mode generator is working spendidly; this is the system using a Pockels cell and fast high voltage switching supply from Lasermetrics. G0 Collaboration Mtg (August 16, 2002), 3

Homebuilt beam results - August 8th Quickly delivered 12 µa beam to FC2 with better than 50% transmission, an improvement over tests with past lasers. Found that we would lose G0 beam shortly after the gun when exceeding 50 µa from gun. We could not determine where or why the beam vanished. Delivered > 20 µa to FC1, but were limited to ~ 17 µa at FC2 because of BLM trips at aperture A3. Bleedthrough/leakage very small (not measurable) with this laser. Electron bunch grows dramatically with increasing G0 beam current. Current (µa) 2 181 5 227 10 272 16 318 31 409 Bunchlength (ps) >46 Double pulse G0 Collaboration Mtg (August 16, 2002), 4

Homebuilt beam results - August 9th Harp scans with G0 beam at varying beam intensity were taken in the 100keV region to provide data on beam "disappearance > 50µA. QE vs beam current with diode and G0 lasers were measured. Performed 30 Hz noise measurement. At the end of the second day, using nominal setting we delivered (with the use of the prebuncher): 11µA to in line dump with 80% transmission, 17µA to in line dump with 38% transmission, without BLM trips. The above measurements were performed with an injector that was capable for delivering >100 µa of diode beam. G0 Collaboration Mtg (August 16, 2002), 5

QE ok, yet beam loss onset appears Gun current Pcup current G0 Collaboration Mtg (August 16, 2002), 6

30 Hz Noise Measurement I = 10µA at 5 MeV BCM σ < 0.2% G0 Collaboration Mtg (August 16, 2002), 7

Time-Bandwidth Laser The TIGER laser arrived Wednesday and was unboxed... G0 Collaboration Mtg (August 16, 2002), 8

Time-Bandwidth Laser Thursday, with the Time Bandwidth designer the system was connected, turned on and began pulsing... G0 Collaboration Mtg (August 16, 2002), 9

Time-Bandwidth Laser Passive mode-locking is achieved using SESAM technology and a PLL to the reference 31.1875 MHz RF source. G0 Collaboration Mtg (August 16, 2002), 10

Time-Bandwidth Laser Performance Measured > 300 mw at 840 nm; tunable from 770-860 nm. Measured pulse width ~ 70 ps fwhm. Etalons for 15 ps, 33 ps, 50 ps, and 70 ps received. Phase jitter measured < 700 fs. Laser has met spec. Training and testing in progress. G0 Collaboration Mtg (August 16, 2002), 11

Parity controls overview 3 hall operation means our laser configuration has constraints Independent intensity control for each end station. This mean additionally providing parity quality intensity and position devices for both G0 and HAPPEx2. Hall B continues running a diode laser and TACO intensity feedback. Independent position feedback for the parity Halls (A&C). Asymmetry Lock Server provides G0 access to control parity devices G0 Collaboration Mtg (August 16, 2002), 12

Parity devices common to all lasers PZT X/Ykinematicmount Insertable l/2 waveplate for systematic helicity reversal 20 mm l/4 waveplate Pockels cell for CP and PITA Rotatable l/2 waveplate G0 Collaboration Mtg (August 16, 2002), 13

Parity devices independent to a laser Independent intensity control using 10 mm LV IA Pockels cell Independent position control using pico-pzt kinematic mount G0 Collaboration Mtg (August 16, 2002), 14

Independent intensity control λ/10 α IA V Output Beam Follows laser directly Stable slope ~300 ppm/v Low cell voltage Low insertion loss Compact footprint (Tsentalovich, BATES) G0 Collaboration Mtg (August 16, 2002), 15

IA bench test G0 Collaboration Mtg (August 16, 2002), 16

IA beam test (Hall A) G0 Collaboration Mtg (August 16, 2002), 17

Independent position control We use a mirror mounted to a kinematic stage with PZT stacks for laser deflection. The common mirror is ~10 cm upstream of the Pockels cell. To achieve independent postion control we retrofit a picomotor controlled mirror with a PZT kinematic mount. This doubles the moment arm to the cathode, but also increases the distance (100 cm) to the Pockels cell. G0 Collaboration Mtg (August 16, 2002), 18

Issues regarding position feedback HC motion at injector apertures produce charge asymmetry. Original aperture set produced Q asym ~ 300-400 ppm/volt. 2x aperture set reduced to this to < 40 ppm/volt. A 3x+ aperture set exists and hasn t yet been tested. HC motion on the cathode QE surface produces charge asymmetry. A clean measurement to determine contribution from cathode QE surface vs. apertures remains to be tested soon (next week?). PZT kinematic mount is not perfect. Recent bench tests using 10V modulation shows no cross-talk at the orthogonal stack, but about 0.1% cross-talk at the coupled stack. Test also shows ~0.5% ringing for 5 msec at each stack. Better news is PZT feedback probably requires <1 Volt. HAPPEx2 is considering the possibility of employing HC magnets. G0 Collaboration Mtg (August 16, 2002), 19

Asymmetry Lock Server ALS provides G0 access via EPICS to control parity devices Good track record and is being improved for User readback G0 Collaboration Mtg (August 16, 2002), 20

Injector beam monitors BPM s # Energy Quality 1 100 kev Prior to any apertures 3 100 kev Between Wien & A1 1 100 kev Between A1 & A2 1 100 kev After chopper 3 5 MeV After all apertures BCM s # Energy Quality 1 5 MeV After all apertures S/H s # Energy Quality 6 100 kev Temporary 3 100 kev Permanent 3 5 MeV Permanent G0 Collaboration Mtg (August 16, 2002), 21

Injector DAQ 32 channel scaler based DAQ Triumf V/F s BPM s = 4 channels BCM = 1 channel Improve laser setup EES recently ran cables from tunnel to DAQ to analyze photodiode signals from tunnel. Jeff Secrest & Sue Witherspoon Upgrade DAQ to Ops IOC w/ PowerPC Implement EPICS analysis output Improve data storage HAPPEx2 ADC DAQ Located in same crate Analyzes mostly same signals Redundancy/debugging G0 Collaboration Mtg (August 16, 2002), 22

Injector beam monitoring Because injector diagnostics see all 3 beams HC measurement and feedback is presently limited. A drawing board idea for independent capability: Requires a beam intensity modulation (~1 khz) RF VME boards with DSP to use lock-in technique Project has Operations support Initial test using the injector BCM before 2003 G0 Collaboration Mtg (August 16, 2002), 23

Timeline & Conclusions We are in the midst of reaching many important G0 milestones. We are making progress both on the laser front, beam transport front, and parity front. Next week we will: complete injector parity controls installation prepare an injector setup for G0 beam perform injector parity measurements deliver that beam to Hall C Now, Mark can tell us what he s planning and hoping for... G0 Collaboration Mtg (August 16, 2002), 24