Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Similar documents
Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

PicoScope 6407 Digitizer

Digital Storage Oscilloscopes 2550 Series

PicoScope 6407 Digitizer

SDS1000C Specifications

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

ScopeMeter 190 Series Specifications

DataSheet. SDS1000DL Series Digital Oscilloscope

50 MHz Digital Storage Oscilloscope

DataSheet SDS1000CFL Series Digital Oscilloscope

DataSheet SDS1000CML Series Digital Oscilloscope

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

PicoScope 4000 Series PC Oscilloscopes

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.

PicoScope 4000 Automotive PC Oscilloscopes

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

PicoScope 4000 Series PC Oscilloscopes

ADS1000C, CAL / CML Series

2016 RIGOL TECHNOLOGIES, INC.

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

2 MHz Lock-In Amplifier

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

PicoScope 6000 Series HIGH-PERFORMANCE USB OSCILLOSCOPES

PicoScope 3000 Series Automotive User guide

R&S RT-Zxx High-Voltage and Current Probes Specifications

PicoScope 2000 Series 2-CHANNEL OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

PicoScope 3000 Series

Agilent Technologies 54522A

Expect to Make Waves.

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Agilent 5345A Universal Counter, 500 MHz

3000 Series. PicoScope. USB oscilloscopes

PicoScope 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

PicoScope 3000 Series HIGH-PERFORMANCE 4-CHANNEL OSCILLOSCOPES

Advanced Test Equipment Rentals ATEC (2832)

Oscilloscopes, logic analyzers ScopeLogicDAQ

PicoScope 3000 Series PC Oscilloscopes

SDS1000CNL+ Series Digital Oscilloscope. DataSheet

PicoScope 3000 Series

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Digitizing Oscilloscopes

PicoScope 2203, 2204, 2205 PC Oscilloscopes

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

SDS1000DL+/CML+ Series Digital Oscilloscope. DataSheet

PicoScope 2000 Series PC Oscilloscopes

2000 Series. PicoScope. The compact alternative to a benchtop oscilloscope

2000 Series. PicoScope. The compact alternative to a benchtop oscilloscope

2 MHz Lock-In Amplifier

System Requirements SA0314 Spectrum analyzer:

4 MHz Lock-In Amplifier

PicoScope 3000 Series USB OSCILLOSCOPES AND MIXED-SIGNAL OSCILLOSCOPES. 2 AnAlog ChAnnels serial DeCoDIng MATh ChAnnels

Portable Performance for Debug and Validation

ATS MS/s 8-Bit PCI Digitizer

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

20 GHz bandwidth 17.5 ps rise time

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

PicoScope 9200A PC Sampling Oscilloscopes for Windows PCs

2000 Series. PicoScope. The compact alternative to a benchtop oscilloscope

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

R3267/3273 Spectrum Analyzers

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Digitizing Oscilloscopes (2009)

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

What to look for when choosing an oscilloscope

Datasheet SHF A

PicoScope 6000 Series HIGH-PERFORMANCE USB OSCILLOSCOPES

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

R&S RT-Zxx Standard Probes Specifications

Introduction to the oscilloscope and digital data acquisition

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

WaveDriver 20 Potentiostat/Galvanostat System

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

MICROWAVE MEASURING INSTRUMENTS

Fluke /

PicoScope 9200A PC Sampling Oscilloscopes for Windows PCs

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories


PicoScope 9200A PC Sampling Oscilloscopes for Windows PCs

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

Choosing an Oscilloscope

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

Digital Oscilloscope. Characterisation, Measurement & Analysis

Spectrum Analyser Basics

20 years of ScopeMeter Test Tool Innovation Introducing the complete 190 Series II Technical Data. New 500 MHz

Transcription:

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Oscilloscope/ Spectrum Analyzer/ Data Recorder Model SA985 SA975 SA935 SA915 Oscilloscope (Typical by Design) Bandwidth (Max at probe tip) [1] @ 500 mv/ Div with 10X probe @ 50 mv/ Div with 1X probe @ 1 V/ Div with 10X probe @ 100 mv/ Div with 1X probe @ 2 V/ Div with 10X probe @ 200 mv/ Div with 1X probe @ 5 V/ Div with 10X probe @ 500 mv/ Div with 1X probe @ 200 V/ Div with 10X probe @ 20 mv/ Div with 1X probe 1 GHz 1 GHz 2 2 2 2 400 MHz 400 MHz 300 MHz 300 MHz 75 MHz 75 MHz Rise time 0.5 ns 1.0 ns 2.5 ns 5.0 ns Input channels 2 Vertical resolution 8 bits DC accuracy ±3% Input characteristics CMRR (Common Mode Rejection Ratio) Channel-to-Channel Over Range Crosstalk Input type Input coupling Input ranges (full scale) 10x probe 1x probe Overload protection Sampling rate (each channel) Real / per channel Effective / per channel 1 MΩ in parallel with 5 pf 30 db (@ ) 250 mv Single ended, BNC connector Software selectable AC/DC ±80 mv to ±80 V in 10 ranges ±8 mv to ±8 V in 10 ranges ±150 V (DC+AC peak) 125 MHz 100 GHz 25 GHz

Vertical Sensitivity 1x probe 10x probe Buffer memory size One channel in use Two channels in use 2 mv - 2 V / DIV 20 mv - 20 V / DIV 1024 KB 512 KB Time-base ranges 1 ns/div to 100 ms/div 5 ns/div to 100 ms/div Time-base ranges ( Data Recorder) 500 ns to 365 days with data recorder Time-base accuracy [2] 50 ppm 100 ppm 200 ppm Trigger modes Normal, auto, one shot, single, Ch1, CH2 Trigger threshold Internal External Basic triggers Adjustable 1.2 Volts External/ CH1/ CH2/ Alternative Rising edge/ Falling edge/ Auto/ Normal/ Single External trigger Trigger threshold Resolution Input characteristics Overload protection ± range setting (variable) 8 bits BNC, 1 MΩ ±10 V External trigger bandwidth 1 GHz 300 MHz Notes: 1- The bandwidth indicates the highest frequency at which a sine wave can be represented by the oscilloscope with a 10 db loss. This also applies for narrow band signals. For non-periodical wide band signals the bandwidth is limited by the Nyquist criteria. For the specified real time sampling rate of 120 MHz, the bandwidth is limited to about. 2- For a better performance, please contact the factory.

Model SA985 SA975 SA935 SA915 Spectrum Analyzer (Typical by Design) [3] The same specifications apply to the common features of the oscilloscope and the spectrum analyzer in the model. Frequency Bandwidth [4] 1 GHz 300 MHz Display Span 204.8 KHz to 60 MHz Resolution Spectrum Flatness ( Span / 2^18 ) 0.78 Hz to 195 Hz 1 db Frequency Error [5] 50 ppm 100 ppm 200 ppm Measurement Uncertainty > 3% (standard) >0.6% (special) Maximum number of bins 1M Dynamic Range 8 bits (<65 db) Distortion Spurious Response Frequency Response 50 db ±0.5 db Reference Levels (10 ranges) 1x Probe 10x Probe - 35 dbv to 25 dbv (0.6 to 5.623 VRMS) - 25 dbv to 35 dbv (0.06 to 56.23 VRMS) Display modes Sampling, peak hold, average, history Windowing types Rectangular, Bartlett, Gaussian (2.5, 3.5, 4.5), Triangular, Blackman, Blackman Harris, Hamming, Hanning, Welch, Kaiser Bessel, Flat Top,

Model SA985 SA975 SA935 SA915 Frequency Analyzer (All Models, Typical by Design) [3] The same specifications apply to the common features of the oscilloscope and the frequency and phase analyzer in the model. Bandwidth [4] 1 GHz 300 MHz Resolution 0.1 Hz Tolerance [5] 50 ppm 100 ppm 200 ppm Relative Tolerance 0.01 ppm 0.1 ppm 1 ppm Data Recorder (All Models, Typical by Design) [3] The same specifications apply to the common features of the oscilloscope and the data recorder in the model. Sampling Interval 102 MHz to 10 phz Time-base ranges 500 ns to 365 days Time Accuracy [5] 50 ppm 100 ppm 200 ppm Notes: 3- The relevant specification for the oscilloscope also applies to the spectrum analyzer, frequency analyzer, and data recorder of the corresponding model. 4- The bandwidth indicates the highest frequency at which a sine wave can be represented by the instrument with a 10 db loss. This also applies for narrow band signals. For non-periodical wide band signals the bandwidth is limited by the Nyquist criteria. For the specified real time sampling rate of 120 MHz, the bandwidth is limited to about. 5- For a better performance, please contact the factory.

Physical Properties Dimensions 128.0 x 77.0 x 31.6 (mm), 5.0 x 3.0 x 1.2 (inches) Weight 255 grams, 9 oz Other PC Requirements Recommended Environmental Operating environment Temperature range Humidity Storage environment Temperature range Humidity Software Operating system: 32/ 64-bit edition of Microsoft Windows XP (SP3), Vista, Windows 7/ Windows 8/ Windows 10 Ports: USB 2.0/ 3.0 compliant port 0 C to 40 C for normal operation 15 C to 32 C for quoted accuracy 5% to 80% RH, non condensing -20 C to +60 C 5% to 95% RH, non condensing Save setting, recall setting, save plot, recall/print plot, zoom in vertical, zoom in horizontal, pen editor, line editor, DSP, variable sampling rate