DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire: 0 0 ma / 0 0 V Special characteristics mechanical connection: G/4" flush suitable for viscous and pasty media Optional versions several electrical connection specific versions IS-version Ex ia = intrinsically safe for gases and dusts The industrial pressure transmitter type DMP 9 with flush diaphragm has been especially designed for use in dosing systems. The transmitter is suited for pressure measuring of adhesive, highly viscous oils, colors and pastes, which stringently need the G/4" flush pressure port. BD SENSORS typically, a multitude of electrical connections, which the integration into the plants alleviate, stand by for users. The DMP 9 stands for highest economics and reliability, because material accumulation on impedance discontinuity, the drip on the blast pipe or the cob webbing of adhesive can be avoided. Preferred areas of use are Preferred using in Plant and Machine Engineering - especially conveyor plants and dosing systems Hydraulics Fuels / Oils Pasty media BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 5 / 98 - info@bdsensors.de
DMP 9 Input pressure range Nominal pressure gauge / abs. [bar] 60 00 60 50 400 600 Overpressure [bar] 0 0 600 600 050 050 Burst pressure [bar] 00 00 00 00 500 500 Nominal pressure P N < 60 bar on request Output signal / Supply Standard -wire: 4... 0 ma / V S = 8... V DC Option IS-protection -wire: 4... 0 ma / V S = 0... 8 V DC Options -wire -wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy ± 0.5 % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0 A] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Tolerance band ± % FSO in compensated range -0... 85 C Permissible temperatures Permissible temperatures medium: -40... 5 C electronics / environment: -40... 85 C storage: -40... 00 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 00 g / msec according to DIN EN 60068--7 Materials Pressure port stainless steel.4548 (7-4 PH ERS) for G/4" flush (DIN 85) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated Seals FKM on pressure port G/4" flush Diaphragm stainless steel.445 (6 L) Media wetted parts pressure port, diaphragm Explosion protection (only for 4... 0 ma / -wire) Approval DX9-DMP 9 Safety technical maximum values Permissible temperatures for environment Connecting cables (by factory) IBExU 0 ATEX 068 X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex iad 0 T85 C U i = 8 V DC, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh, C ignd 7 nf -0... 70 C cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight approx. 0 g Installation position any Operational life > 00 x 0 6 pressure cycles CE-conformity EMC Directive: 004/08/EC Pressure Equipment Directive: 97//EC (module A) 4 Pressure transmitters are calibrated in a vertical position with the pressure connection down. 4 This directive is only valid for devices with maximum permissible overpressure > 00 bar pressure measurement
DMP 9 Wiring diagrams -wire-system (current) p supply + -wire-system (current / voltage) supply + p V S V S supply I supply I/U signal + A/V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (for -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) 4 Mx / Metall (4-pin) Shield ground pin 5 4 field housing IN + IN OUT + cable colours (DIN 4700) wh (white) bn (brown) gn (green) gn/ye (green / yellow) standard option ISO 4400 Binder Series 7 5-pin Mx 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 5 compact field housing (IP 67) cable outlet, cable with ventilation tube (IP 68) 6 universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 metal (ordering code 880) and other versions on request 5 standard: m PVC cable without ventilation tube (permissible temperature: -5... 70 C) 6 different cable types and lengths available, permissible temperature depends on kind of cable www.bdsensors.com
DMP 9 Mechanical connections (dimensions in mm) with FKM seal on pressure port G/4" flush DIN 85 This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. pressure measurement Telefon +49 (0) 9 5 / 98-0 Telefax +49 (0) 9 5 / 98 - www.bdsensors.com info@bdsensors.de DMP9_E_007
Fax: +49 (0) 9 5 / 98 - Ordering code DMP 9 DMP 9 - - - - - - - Pressure gauge absolute Input [bar] Output 5 6 60 6 0 0 00 0 0 60 6 0 50 5 0 400 4 0 0 600 6 0 0 9 9 9 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire E Intrinsic safety 4 0 ma / -wire Accuracy 0.5 % Electrical connection Male and female plug ISO 4400 Male plug Binder series 7 (5-pin) Cable outlet with PVC cable Cable outlet Male plug Mx (4-pin) / metal 0 0 0 0 T A 0 T R 0 M 0 Compact field housing stainless steel.405 (0) 8 5 0 9 9 Mechanical connection G/4" DIN 85 with flush sensor F 0 9 9 Seals FKM on pressure port P Special version standard 0 0 0 9 9 nominal pressure gauge P N < 60 bar on request standard: m PVC cable without ventilation tube (permissible temperature: -5 70 C), cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable BD SENSORS GmbH BD-Sensors-Straße Telefon +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Telefax +49 (0) 9 5 / 98 - info@bdsensors.de 008 This ordering code contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.