DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Similar documents
DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMP 331i / DMP 333i LMP 331 i

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Pressure transmitter For applications in hazardous areas Model IS-3

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor With analog output BI15-M30-LI-EXI

TFRN Industrial RTD temperature sensor. CombiTemp TM

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

TFRN Industrial RTD temperature sensor. CombiTemp TM

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

PMG. Vibration Energy Harvesters

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Photoelectrics Through-beam Type PA18C.T..., DC

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

RSCC. Load cells. Special features. Data sheet

Quality products from a single source

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Level Measurement silometer FMC 420, FMC 423

PROPORTIONAL VALVES Sentronic plus

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

APPLICATIONS. Automatic warehouse. Trasportation lines

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Selection matrix for electronic pressure switches

Single Point Flow Monitor SW118 SW119

APPLICATIONS. Automatic warehouse. Trasportation lines

Process transmitter RMA422

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Capacitance Level Measurement Electronic insert FEC 12

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Pressure transmitter COMPACT IO-Link,

Eddy Current Probe System

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Linear encoders without bearings incremental System for linear motion feedback

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Process Transmitter RMA 422

Flow Switch. Flow Switch

Micro-Machined Silicon Transducers

Absolute Encoders Multiturn

Mechanical flow switch for On/Off control

Panel-mounting Thermostats EM Series

The full range of performance

Quality products from a single source

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Speed sensor MiniCoder GEL 2471

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

3 Cleaning. 4 Technical data

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

TFR5 Room or outdoor temperature sensor. CombiTemp TM

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Capacitance Limit Detection nivotester FTC 420/421/422

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Level Measurement Point level measurement - RF Capacitance switches

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Capacitive sensor BCT5-S18-UP6X2T-H1151

Linear flow control with actuator IFC

SERIES 400 SERIES 620

Photoelectric Sensors E3F2

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

M5 plug connector, 3-pin or hard-wire encapsulated cable. With. With connection cable. M5 plug connector. Active face LED

Transcription:

DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire: 0 0 ma / 0 0 V Special characteristics mechanical connection: G/4" flush suitable for viscous and pasty media Optional versions several electrical connection specific versions IS-version Ex ia = intrinsically safe for gases and dusts The industrial pressure transmitter type DMP 9 with flush diaphragm has been especially designed for use in dosing systems. The transmitter is suited for pressure measuring of adhesive, highly viscous oils, colors and pastes, which stringently need the G/4" flush pressure port. BD SENSORS typically, a multitude of electrical connections, which the integration into the plants alleviate, stand by for users. The DMP 9 stands for highest economics and reliability, because material accumulation on impedance discontinuity, the drip on the blast pipe or the cob webbing of adhesive can be avoided. Preferred areas of use are Preferred using in Plant and Machine Engineering - especially conveyor plants and dosing systems Hydraulics Fuels / Oils Pasty media BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 5 / 98 - info@bdsensors.de

DMP 9 Input pressure range Nominal pressure gauge / abs. [bar] 60 00 60 50 400 600 Overpressure [bar] 0 0 600 600 050 050 Burst pressure [bar] 00 00 00 00 500 500 Nominal pressure P N < 60 bar on request Output signal / Supply Standard -wire: 4... 0 ma / V S = 8... V DC Option IS-protection -wire: 4... 0 ma / V S = 0... 8 V DC Options -wire -wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy ± 0.5 % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0 A] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Tolerance band ± % FSO in compensated range -0... 85 C Permissible temperatures Permissible temperatures medium: -40... 5 C electronics / environment: -40... 85 C storage: -40... 00 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 00 g / msec according to DIN EN 60068--7 Materials Pressure port stainless steel.4548 (7-4 PH ERS) for G/4" flush (DIN 85) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated Seals FKM on pressure port G/4" flush Diaphragm stainless steel.445 (6 L) Media wetted parts pressure port, diaphragm Explosion protection (only for 4... 0 ma / -wire) Approval DX9-DMP 9 Safety technical maximum values Permissible temperatures for environment Connecting cables (by factory) IBExU 0 ATEX 068 X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex iad 0 T85 C U i = 8 V DC, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh, C ignd 7 nf -0... 70 C cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight approx. 0 g Installation position any Operational life > 00 x 0 6 pressure cycles CE-conformity EMC Directive: 004/08/EC Pressure Equipment Directive: 97//EC (module A) 4 Pressure transmitters are calibrated in a vertical position with the pressure connection down. 4 This directive is only valid for devices with maximum permissible overpressure > 00 bar pressure measurement

DMP 9 Wiring diagrams -wire-system (current) p supply + -wire-system (current / voltage) supply + p V S V S supply I supply I/U signal + A/V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (for -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) 4 Mx / Metall (4-pin) Shield ground pin 5 4 field housing IN + IN OUT + cable colours (DIN 4700) wh (white) bn (brown) gn (green) gn/ye (green / yellow) standard option ISO 4400 Binder Series 7 5-pin Mx 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 5 compact field housing (IP 67) cable outlet, cable with ventilation tube (IP 68) 6 universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 metal (ordering code 880) and other versions on request 5 standard: m PVC cable without ventilation tube (permissible temperature: -5... 70 C) 6 different cable types and lengths available, permissible temperature depends on kind of cable www.bdsensors.com

DMP 9 Mechanical connections (dimensions in mm) with FKM seal on pressure port G/4" flush DIN 85 This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. pressure measurement Telefon +49 (0) 9 5 / 98-0 Telefax +49 (0) 9 5 / 98 - www.bdsensors.com info@bdsensors.de DMP9_E_007

Fax: +49 (0) 9 5 / 98 - Ordering code DMP 9 DMP 9 - - - - - - - Pressure gauge absolute Input [bar] Output 5 6 60 6 0 0 00 0 0 60 6 0 50 5 0 400 4 0 0 600 6 0 0 9 9 9 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire E Intrinsic safety 4 0 ma / -wire Accuracy 0.5 % Electrical connection Male and female plug ISO 4400 Male plug Binder series 7 (5-pin) Cable outlet with PVC cable Cable outlet Male plug Mx (4-pin) / metal 0 0 0 0 T A 0 T R 0 M 0 Compact field housing stainless steel.405 (0) 8 5 0 9 9 Mechanical connection G/4" DIN 85 with flush sensor F 0 9 9 Seals FKM on pressure port P Special version standard 0 0 0 9 9 nominal pressure gauge P N < 60 bar on request standard: m PVC cable without ventilation tube (permissible temperature: -5 70 C), cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable BD SENSORS GmbH BD-Sensors-Straße Telefon +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Telefax +49 (0) 9 5 / 98 - info@bdsensors.de 008 This ordering code contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.