RADIOGRAPHIC PERFORMANCE OF CYGNUS 1 AND THE FEBETRON 705

Similar documents
TEST WIRE FOR HIGH VOLTAGE POWER SUPPLY CROWBAR SYSTEM

Fig. 1. Hawk switch/load vacuum section in the standard configuration.

HIGH VOLTAGE SWITCH PERFORMANCE OF THE EIMAC X-2159 TETRODE ABSTRACT

STUDIES OF ENHANCED EDGE EMISSION OF A LARGE AREA CATHODE *

A Comparison of the Temporal Characteristics of LCS, LCoS, Laser, And CRT Projectors

REPORT DOCUMENTATION PAGE

DESIGN AND PERFORMANCE OF THE MARX GENERATOR FOR THE DARHT SECOND AXIS ELECTRON INJECTOR*

w. R. Scarlett, K. R. Andrews, H. Jansen

REFLEX TRIODE X-RAY SOURCE RESEARCH ON GAMBLE II

Applying LaPO 4 Phosphor via Spinning for BetaPhotovoltaic Devices

Computational Studies of X-ray Framing Cameras for the National Ignition Facility

Search Strategies for a Wide-Field Electro-Optic Sensor

A Look-up-table Approach to Inverting Remotely Sensed Ocean Color Data

RATE-ADAPTIVE VIDEO CODING (RAVC)

THE EXPLOSIVE PULSED POWER TEST FACILITY AT AFRL

UNITED STATES AIR FORCE RESEARCH LABORATORY

-REO. * This work supported by U.S. Dept. of Energy under

Continued Development of the Look-up-table (LUT) Methodology for Interpretation of Remotely Sensed Ocean

29.1 PULSED POWER BIBLIOGRAPHY. R. L. Druce and A. H. Guenther Air Force Weapons Laboratory (CA) Kirtland AFB Albuquerque, NM 87117

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

THE LIQUID METAL PLASMA VALVE CLOSIN"G SWITCH. John R. Bayless Hughes Research Laboratories 3011 Malibu Canyon Road Malibu, California

Elements of a Television System

Processing the Output of TOSOM

AFRL-RY-WP-TR

Standard Operating Procedure of nanoir2-s

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Multiple Target Laser Designator (MTLD)

REPORT DOCUMENTATION PAGE

4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER. 6. AUTHOR(S) 5d. PROJECT NUMBER

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

More Info at Open Access Database Process Control for Computed Tomography using Digital Detector Arrays

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Current Status of the Laser Diode Array Projector Technology

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland

TESLA FEL-Report

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

Beam test of the QMB6 calibration board and HBU0 prototype

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

The State of Remote Scientific Visualization Providing Local Graphics Performance to Remote ARL MSRC Users

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

DARHT II Scaled Accelerator Tests on the ETA II Accelerator*

Intra-oral X-ray unit with high frequency DC generator. Product Data

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

Computer Graphics Hardware

Mahdad Manavi LOTS Technology, Inc.

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

This work was supported by FINEP (Research and Projects Financing) under contract

Progress Update FDC Prototype Test Stand Development Upcoming Work

CBF500 High resolution Streak camera

TIL311 HEXADECIMAL DISPLAY WITH LOGIC

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

Display Systems. Viewing Images Rochester Institute of Technology

Modulation transfer function of a liquid crystal spatial light modulator

Swept-tuned spectrum analyzer. Gianfranco Miele, Ph.D

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

A New 4MW LHCD System for EAST

Quadrupoles have become the most widely used

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

Light Emitting Diodes (LEDs)

INSTRUMENT CATHODE-RAY TUBE

Low-Energy Electron Linacs and Their Applications in Cargo Inspection

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Mechanical aspects, FEA validation and geometry optimization

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

PV Series 850 nm VCSELs. Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)


Reading. Display Devices. Light Gathering. The human retina

2.2. VIDEO DISPLAY DEVICES

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

25W 9xxnm Uncooled Multimode Laser Diode Module

EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

ITS-I. Test station for evaluation of image quality of image intensifier tubes. Fig. 1. Photo of the ITS-I test station: a)photo, b)block diagram

New Filling Pattern for SLS-FEMTO

The hybrid photon detectors for the LHCb-RICH counters

REAL-TIME DISPLAY OF RADIATION FIELD INTENSITY DISTRIBUTION. P. A. Berardo J. A. Willis

Challenges in the design of a RGB LED display for indoor applications

DELTA MODULATION AND DPCM CODING OF COLOR SIGNALS

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

Pulsed Klystrons for Next Generation Neutron Sources Edward L. Eisen - CPI, Inc. Palo Alto, CA, USA

High-Current Hollow Cathode Development *

Industrial Diode Laser (IDL) System IDL Series

CMPE 466 COMPUTER GRAPHICS

Comp 410/510. Computer Graphics Spring Introduction to Graphics Systems

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

Fiber Type Core/Cladding (um) Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

RF MEMS IMPROVEMENT PROGRAM

Thyratrons. High Energy Switches. Features. Description

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

Y.XST225-VF. INTERCONTROLE Escoffier 1 XYLON MG225VF RX PDS

Compact Size Perfect for rack mount router and other applications with space limitations.

3-D position sensitive CdZnTe gamma-ray spectrometers

IMPROVEMENTS IN LOW POWER, END-WINDOW, TRANSMISSION-TARGET X-RAY TUBES

arxiv:hep-ex/ v1 27 Nov 2003

Transcription:

RADIOGRAPHIC PERFORMANCE OF CYGNUS 1 AND THE FEBETRON 705 E. Rose ξ, R. Carlson, J. Smith Los Alamos National Laboratory, PO Box 1663, Mail Stop P-947 Los Alamos, NM 87545, USA Abstract Spot sizes are measured for medium energy x-ray generators. The Cygnus x-ray source [1] is developed for support of the Sub-Critical Experiments Program at the Nevada Test Site. Cygnus uses proven pulsed power technology to drive a rod pinch diode at 2.25 megavolts. Four rads at one meter is achieved in a 50-ns FWHM pulse and the radiographic spot size is as small as 1 mmdiameter. Radiographic spot size is measured employing roll bars and resolution targets. Images are recorded on film and storage phosphor, digitized, and analyzed. The Febetron 705 x-ray source operates at 2.3 megavolts and is rated at 500 millirads at one meter. A demountable diode tube provides the ability to replace the standard diode with custom hardware. Spot sizes for standard hardware are measured. New diode designs are investigated in an effort to generate smaller radiographic spot sizes to produce improved radiographic images. I. IMPORTANCE OF SMALL SPOT SIZE The control of several parameters are required to produce a radiograph of high quality. Three obvious contributors to quality are: film blur, motion blur and spot size. This paper deals with spot size. Small spot size contributes to a high quality radiograph by casting a sharp shadow. Another way to express this, in mathematical terms, is that a small spot has high spatial frequency components. Small features in the object will be illuminated by high spatial frequency components of the irradiating beam and obscured by low spatial frequency components. One way to minimize the problem of large spot size is to bring the recording medium close to the object. Photographic contact prints use this method. However, images are limited to a one-to-one magnification. For x- ray radiography, objects are often three dimensional, so strict contact with the recording medium cannot be maintained. Radiographs of objects in the process of exploding also recommend themselves for techniques that remove the recording medium from intimate contact with the object. Typical recording media include film, storage phosphors and digital cameras. We have endeavored to produce an x-ray generator capable of producing a nominal 1-mm spot size to meet the requirements of our experiment. II. CYGNUS I Two Cygnus x-ray generators are designed for use underground. This requirement has driven the design to produce a narrow generator, with the Marx bank, pulse forming line, inductive voltage adder and diode in line with each other. Two x-ray generators allow images to be obtained from two views at two times. Two generators, placed in line with each other, create a narrow footprint, consistent with underground siting. The x-ray generating diode is of the rod pinch type [2]. A thin anode rod protrudes through an annular cathode. A positive pulse on the anode produces electrons from the cathode. There is an interaction between electric forces from the diode and magnetic forces from the electron current, complicated by plasma generation on the anode. The rod pinch diode on Cygnus is remarkable for producing a 1-mm scale spot size for 50 ns with relatively constant impedance, approximately 35 ohms. Figure 1. Operation of Cygnus with a rod pinch diode. Voltage waveform peaks at 2.2 MV. Current peaks at 60 ka. Impedance falls during the pulse. Radiation is monitored using thermoluminescent detectors and a PIN diode. Four rads at a meter is Work supported by the US Dept of Energy under contract W-7405-ENG-36. ξ email: ear@lanl.gov 0-7803-7915-2/03/$17.00 2003IEEE. 756

Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE JUN 2003 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Radiographic Performance Of Cygnus 1 And The Febetron 705 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Los Alamos National Laboratory, PO Box 1663, Mail Stop P-947 Los Alamos, NM 87545, USA 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release, distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES See also ADM002371. 2013 IEEE Pulsed Power Conference, Digest of Technical Papers 1976-2013, and Abstracts of the 2013 IEEE International Conference on Plasma Science. IEEE International Pulsed Power Conference (19th). Held in San Francisco, CA on 16-21 June 2013. U.S. Government or Federal Purpose Rights License. 14. ABSTRACT Spot sizes are measured for medium energy x-ray generators. The Cygnus x-ray source [1] is developed for support of the Sub-Critical Experiments Program at the Nevada Test Site. Cygnus uses proven pulsed power technology to drive a rod pinch diode at 2.25 megavolts. Four rads at one meter is achieved in a 50-ns FWHM pulse and the radiographic spot size is as small as 1 mmdiameter. Radiographic spot size is measured employing roll bars and resolution targets. Images are recorded on film and storage phosphor, digitized, and analyzed. The Febetron 705 x-ray source operates at 2.3 megavolts and is rated at 500 millirads at one meter. A demountable diode tube provides the ability to replace the standard diode with custom hardware. Spot sizes for standard hardware are measured. New diode designs are investigated in an effort to generate smaller radiographic spot sizes to produce improved radiographic images. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR a. REPORT b. ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 4 19a. NAME OF RESPONSIBLE PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

measured. The PIN diode waveform scales with the current and voltage waveforms. III. SPOT SIZE MEASUREMENTS Spot sizes were measured with two techniques: roll bar and resolution target. A. Roll Bar Method A roll bar is set up between the diode and a film cassette or a storage phosphor. The roll bar is a thick [10 cm] piece of tungsten in the shape of an L. The facing surfaces of the L are machined with a 1-m radius, to simplify alignment. Each leg of the L is 16 cm long. The shadow cast by the roll bar is recorded on the film or storage phosphor. The film cassette is loaded (starting with the material closest to the radiation) with 20 mils of lead, Fuji industrial x-ray film [150 NIF], 20 mils of lead, Kodak Industrex AA400 film [100 NIF}, 40 mils of lead. The loading sequence ensures a wide dynamic range. By way of illustration, assume an ideal x-ray spot that is circular and of uniform intensity, as in Figure 2. The image produced by an ideal roll bar is the same as that produced by an opaque half-plane. As a point is moved from shadow to light, the shape of the intensity curve produces the step response function of Figure 3. The step response function is differentiated in space to yield the line spread function of Figure 4. The line spread function contains spatial frequency information about the original x-ray source. This information can be recovered by performing a Fourier transform on the line spread function, shown in Figure 5. The spot size is defined by the 50% point on the modulation transfer function curve. The inverse of the spatial frequency, divided by 1.4, gives the spot diameter. Figure 3. Step response function of the circular spot. Figure 4. Line spread function of the circular spot. Figure 5. Modulation transfer function of the circular spot, plotted on logarithmic scales. The modulation transfer function for three easily modeled beam profiles is shown in Figure 6. All have a 1-mm diameter spot size. (At higher spatial frequencies, the Bennett curve lies above the gaussian curve.) Figure 2. Point spread function of a circular spot with uniform intensity. B. Roll Bar Results Cygnus was operated at 2.25 MV with 0.5-mm diameter gold rods and tapered 0.75-diameter tungsten rods. Although gold rods produced smaller spots, reliability of diode operation was compromised and a few misfires resulted. Tungsten rods produced slightly larger spots, but high reliability, leading to a decision to use tungsten rods for radiography. 757

Data were obtained for scans across the shadows cast by the X and Y legs of the L-shaped roll bar and for both sets of film. Some results are shown in Figures 7 and 8. spatial filter. The resulting image is characterized by a modulation ratio of maxima and minima in the intensity. Figure 6. Modulation transfer functions for circular, gaussian and Bennett profile x-ray spots. Figure 7. Spot size by shot for 0.5-mm diam gold rods. Figure 9. Resolution target, marked in lines per mm. The pictured resolution target has a rectangular pattern. The target used in the Cygnus experiments was fabricated from 3-mm thick tungsten, 8 cm square. Patterns were obtained using film and storage phosphor. Analysis was performed by matching synthetic radiographs of circular x-ray sources with the experimental results and comparing modulations, defined as the difference in maximal and minimal intensities divided by the sum of intensities. Another analysis technique uses a deconvolution of the image and resolution target to recover the x-ray spot characteristics. The analysis of data using the resolution target method has not progressed as far as the roll bar method. Results so far indicate that the two methods agree. D. Resolution Target Results Figure 10 shows experimental results from a 0.75-mm diameter tungsten rod. The modulation decreases as the spatial frequency increases. Figure 8. Spot size by shot for 0.75-mm diam tungsten rods. The spot diameter for gold rods was 1.08 mm [+-0.05 mm]. The spot diameter for tungsten rods was 1.19 mm [+-0.05 mm]. There was no significant difference between X and Y spot sizes or between the film types. C. Resolution Target Method A second method of analyzing spot size uses a resolution target, shown in Figure 9. The resolution target simulates passing the x-ray source through a sinusoidal IV. FEBETRON 705 The Febetron 705 is a commercially produced x-ray generator, rated at 2.3 MV and 500 millirads at a meter, depending on the diode used. A demountable tube is available, allowing the use of small, expendable anodes. This capability offers the promise of engineering new diode configurations for the Febetron 705 that reduce the spot size. Earlier experiments with a standard diode indicated that the Febetron 705 produced a 9-mm diameter spot size. Our goal is to achieve a 1-mm-scale spot size, comparable to Cygnus. 758

Figure 10. Resolution target images. From left to right and top to bottom: 1.5, 1.2, 0.9 and 0.7 line pairs per mm. Currently, the Febetron 705 is installed in a laboratory, and equipped with a new flange set that allows experimenters to operate with a standard diode tube, demountable diode tube or resistive load. A common diagnostic set is available. A voltage monitor of the E-dot type came as original equipment and has been calibrated against a voltage divider, consisting of a liquid resistor and current viewing resistor, in series. A current monitor of the Rogowski type is mounted in a flange common to all load configurations. We have the ability to monitor voltage and current characteristics of new diode designs, an essential element in understanding and optimizing performance. A key feature of the Febetron 705 is the rapid shot rate with standard diodes. Cygnus can produce three rod pinch shots per day, whereas the Febetron 705 can produce dozens of shots per day. Diagnostic issues associated with Cygnus - such as spot size, dose and energy spectrum are being addressed. Figure 11 shows the voltage pulse shape of the Febetron 705 with a standard diode tube. FWHM pulse width with a 420-ohm resistive load is 80 ns. FWHM pulse width with the diode is 25 ns. Figure 11. Febetron voltage pulse with a 420-ohm resistive load and with a standard diode. V. SUMMARY Cygnus has been operated at 2.25 MV, producing 4 rads at a meter with a 1.2-mm diameter spot size, as determined by roll bar measurements. The second Cygnus x-ray generator is also operating at Titan-PSD. Radiographic experiments are anticipated within the year. A Febetron 705 has been equipped to pursue issues with the Cygnus x-ray generator and small spot size development. VI. REFERENCES [1] J. R. Smith, et al, Performance of the Cygnus X-ray Source, 14th International Conference on High-Power Particle Beams, 2002, p. 135. [2] G. Cooperstein, et al, Theoretical Modeling and Experimental Characterization of a Rod-pinch Diode, Physics of Plasmas 8, 4618-4636, 2001. VII. ACKNOWLEDGEMENTS Steve Lutz (Bechtel Nevada) and Scott Watson (Los Alamos National Laboratory) made significant contributions to the data analysis. 759