Advanced Test Equipment Rentals ATEC (2832)

Similar documents
Agilent 8153A Lightwave Multimeter Technical Specifications

HP 70950B OPTICAL SPECTRUM ANALYZER

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

Agilent 81600B Tunable Laser Source Family

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Keysight Technologies Power Sensor Modules Optical Heads Return Loss Modules. Data Sheet

MAP Optical Power Meter Module (mopm-b1)

Configuring the HP 4396B for O/E Testing. Application Note

25.6 Mb/s (4B/5B) Line Interface

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

OSICS 8-Channel Modular Platform for DWDM Testing

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Broadcast Television Measurements

Agilent 87075C Multiport Test Set Product Overview

MTP1000 with LaserBlade, VOABlade, PowerBlade & SwitchBlade Smarter Modular Test Platform

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

Model 4700 Photodiode Characterizer

1.5/45 Mb/s (DS1/DS3) Line Interface

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

iqs-1600/iqs-1700/ohs-1700 POWER METER AND OPTICAL HEAD SERIES

Keysight Technologies

MTS/T-BERD Platforms WDMPMD Module

OpticalProducts. Illuminating Your Network. Testing the World s Networks

46 GBaud Multi-Format Optical Transmitter

Advanced Test Equipment Rentals ATEC (2832)

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

OTS-300 Express Series Power Meters/Sources and Testers

MTS/T-BERD 8000 Platform

ModBox-1310nm-1550nm-28Gbaud-PAM nm & 1550 nm, 28 Gbaud PAM-4 Reference Transmitter

Optical Component Environmental Test System

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

ModBox-850nm-NRZ-series

OP750. Multichannel Source Instruction Manual

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

Prisma Optical Networks Ancillary Modules

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

Optical Channel Analyzer

OSA20 KEY FEATURES SPEC SHEET OPTICAL SPECTRUM ANALYZER

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

Optical Test and Measurement System AQ8200 Series

Multiwavelength Gain Module EDFA

ED5229GT-E Series. Page 1 of 8

Agilent 81480B, 81680B, 81640B and Agilent 81672B, 81482B, 81682B, & 81642B Tunable Laser Modules. User s Guide

Agilent 11713A Attenuator/Switch Driver

ModBox-CBand-NRZ series C-Band, 28 Gb/s, 44 Gb/s, 50 Gb/s Reference Transmitters

ModBox-1310nm-1550nm-NRZ 1310nm & 1550 nm, 28 Gb/s, 44 Gb/s Reference Transmitters

ED5229GT-E/GTRE Series


Light Source. Specification & User Manual

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

TUNABLE EXTERNAL CAVITY LASERS

AQ2200Series. Ideal Measurement Solution for Optical Devices and Optical Transmission Systems. Multi Application Test System

Exceptional performance

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

MPX / MPZ series. Low frequencies to 32 GHz Phase Modulators. Modulator. Features. Applications. MPX-LN series Performance Highlights

Hand-held Design Brings Peak Performance to the Field. Optical Multimeter AQ2150A

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

JD725A Cable and Antenna Analyzer - Dual Port

THE ART OF ENGINEERING

SCM820 Digital IntelliMix Automatic Mixer SEAMLESS MIXING. ADVANCED CONTROL.

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

O-to-E and E-to-O Converters

Options: - Master Patchcord - Launch cable - Set of optical adapters

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

USB Smart Power Sensor

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

LASERS. Fabry Perot (FP) Distributed Feedback (DFB) Vertical Cavity Surface Emitting Laser (VCSEL)

Compact live fiber identifier with integrated optical power meter

TUNABLE EXTERNAL CAVITY LASERS

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

R&S RSC Step Attenuator Where precise signal levels count

FORWARD PATH TRANSMITTERS

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

POLARIZED FIBER OPTIC SOURCE

Compact EGC Fiber Deep Nodes A90100 and A90300

Photonics solutions For innovative photonics

Full-featured CW Microwave Counters for Field, Factory or Lab

Fiber-Coupled Tunable Optical Filters. Applications. Optical Calibration Instruments and Artifacts.

Alternative Fiber Coupler Options

HP 37722A telecom analyzer HP 37732A telecom/datacom analyzer. Technical specifications

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

Keysight Technologies ad Integrated RF Test Solution

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

MILLIMETER WAVE VNA MODULE BROCHURE

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Cisco RF Gateway 1. Product Overview

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

6 3 0 N M, S I N G L E M O D E F U S E D F I B E R O P T I C C OUPLERS / TA P S

Headend Optics Platform (CH3000)

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: www.agilent.com/comms/lightwave You can also contact one of the following centers and ask for a test and measurement sales representative. United States: Agilent Technologies Test and Measurement Call Center P.O. Box 4026 Englewood, CO 80155-4026 (tel) 1 800 452 4844 Canada: Agilent Technologies Canada Inc. 5150 Spectrum Way Mississauga, Ontario L4W 5G1 (tel) 1 877 894 4414 Europe: Agilent Technologies Test & Measurement European Marketing Organisation P.O. Box 999 1180 AZ Amstelveen The Netherlands (tel) (31 20) 547 9999 Japan: Agilent Technologies Japan Ltd. Measurement Assistance Center 9-1, Takakura-Cho, Hachioji-Shi, Tokyo 192-8510, Japan (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Latin America: Agilent Technologies Latin American Region Headquarters 5200 Blue Lagoon Drive, Suite #950 Miami, Florida 33126 U.S.A. (tel) (305) 267 4245 (fax) (305) 267 4286 Australia/New Zealand: Agilent Technologies Australia Pty Ltd 347 Burwood Highway Forest Hill, Victoria 3131 (tel) 1-800 629 485 (Australia) (fax) (61 3) 9272 0749 (tel) 0 800 738 378 (New Zealand) (fax) (64 4) 802 6881 Asia Pacific: Agilent Technologies 24/F, Cityplaza One, 1111 King s Road, Taikoo Shing, Hong Kong (tel) (852)-3197-7777 (fax) (852)-2506-9284 Related Agilent Literature 8163A Lightwave Multimeter Ordering Guide, p/n 5968-3582E 8163A Lightwave Multimeter Technical Specifications, p/n 5962-9321E 8163A Lightwave Multimeter Configuration Guide, p/n 5968-3581E Technical data is subject to change Copyright 1999 Agilent Technologies Printed in Germany 12/99 (B.O.L.A.Y. GmbH) P/N 5968-3404E

Working together should be a standard. Product Overview Agilent 8163A Lightwave Multimeter precise reliable fast www.agilent.com/comms/lightwave

The New Standard Features and Benefits High High Bandwidth The Agilent 8163A Lightwave Multimeter is a basic measurement tool in the fiber optic industry. It ensures accurate and fast results, even for your most demanding measurements on optical components and systems. The 8163A Lightwave Multimeter is the successor to the highly popular 8153A Lightwave Multimeter. It builds on all the key attributes that made the 8153A Lightwave Multimeter the standard in Research and Development and in Manufacturing. Its modular format makes it flexible enough to meet your changing measurement needs, whether you are measuring optical power, insertion loss or return loss for single- or multimode components. The lightwave multimeter system includes the mainframe and a variety of plug-in modules for set-ups requiring: single or dual channel power meters, single or dual fixed light sources, compact tunable laser modules The Agilent family of optical component test equipment. Because working together should be a standard. The 8163A Lightwave Multimeter helps ease your work-load by offering several advanced functions that turn your 8163A into a powerful measurement system. Without needing an external controller, built-in application software guides you through the step-by-step procedures needed for measurement tasks such as measuring loss, monitoring stability or logging data. For example, for long term monitoring you only need to input the total measurement time and the averaging time per sample the 8163A Lightwave Multimeter does the rest. After the test is complete, the result can be displayed numerically or graphically on the display or the result can be sent to a printer. You can easily integrate the 8163A Lightwave Multimeter into your test environment by using plug & play drivers over GPIB, or by using the configurable hardware input and output trigger ports.

Best possible measurement results Precise, sensitive, stable and fast power measurements You can be sure of the best possible measurement results thanks to the excellent accuracy, high linearity and low polarization dependent loss (PDL) of our full range of power sensors and optical heads. To meet your test requirements, our range of sensors and heads cover the important wavelengths and power ranges you need. And you will like the measurement speed which can come down to 100 µs. A broad variety of advanced interfaces and adapters makes it easy to connect your test devices. Measurements requiring a stable fixed source To take the uncertainty out of monitoring loss over long periods of time, Agilent s sources are stabilized and very insensitive to backreflections. For your convenience there are single and dual wavelength source modules, available with an output power of up to +13 dbm. The output power of the sources can be attenuated for applications where you need lower power levels. Measurements requiring a tunable source If you need to make measurements at various fixed wavelengths, or if the test device must be characterized as a function of wavelength, then the compact tunable laser module is the ideal candidate for your test needs. In combination with a power sensor or an optical head you can setup a complete measurement system for wavelength dependent loss. To help you work efficiently and quickly and to increase your throughput and yield, the input ports are designed to eliminate multiple reflections the cause of many measurement errors. The Agilent 8163A Lightwave Multimeter allows engineers to count on the accuracy of their measurements more than ever. DWDM

Upgradable Firmware To protect your investment for the future, the Agilent 8163A Lightwave Multimeter is designed for easy firmware upgrades as new modules and features become available. Compatibility To protect your existing investment the 8163A mainframe is compatible with the modules from the 8153A Lightwave Multimeter series. Also you can use both the modules of the 8163A and 8153A series together in the 8163A Lightwave Multimeter Mainframe. The programming syntax used by the 8163A Multimeter mainframe is compatible with the 8164A Lightwave Measurement System (the tunable laser family), the 8166A Lightwave Multichannel System and with the 8153A Lightwave Multimeter. The 8163A mainframe is compatible in height and width with the 8153A series, making it easy for you to add or substitute the 8163A to your rack systems. Working together should be a standard. Flexible enough to meet changing measurement needs. High Precision High Precision

Selected Specifications 1) 8163A Lightwave Multimeter Display: Interfaces: Graphical display, monochrome GPIB, RS232C, Parallel Printer Interface (Centronics) Programming*: SCPI Standard, compatible with programming syntax of 8164A Lightwave Measurement System, 8166A Lightwave Multichannel System, 8153A Lightwave Multimeter. *for details please refer to Programming guide P/N 08164-91016 Agilent 81632A 81635A 81633A 81634A Power Sensor Modules (InGaAs) (InGaAs) dual (InGaAs) (InGaAs) Wavelength Range 800 nm to 1650 nm 800 nm to 1700 nm Power Range +10 dbm to -80 dbm +10 dbm to -90 dbm +10 dbm to -110 dbm Uncertainty (accuracy) <±3% (1200 nm to 1630 nm) <±2.5% (1000 nm to 1630 nm) at reference conditions Relative Uncertainty due to Polarization typ ±0.015 db <±0.005 db due to Spectral Ripple typ ±0.015 db <±0.005 db Linearity (power) (CW +10 dbm to -60 dbm) (CW +10 dbm (CW +10 dbm at 23 C ±5 C <±0.02 db ±20 pw to -70 dbm) to -90 dbm) <±0.015 db ±2 pw <±0.015 db ±0.2 pw Agilent 81623A 81624A 81625A Optical Heads 2) (Ge, ø 5 mm) (InGaAs, ø 5 mm) (InGaAs, ø 5 mm) Wavelength Range 750 nm to 1800 nm 800 nm to 1700 nm 850 nm to 1650 nm Power Range +10 dbm to -80 dbm +10 dbm to -90 dbm +20 dbm to -80 dbm Uncertainty (accuracy) <±2.2% <±2.2% <±2.5% at reference conditions (1000 nm to 1650 nm) (1000 nm to 1630 nm) (950 nm to 1630 nm) Relative Uncertainty due to Polarization ±0.005 db ±0.005 db due to Spectral Ripple (typ. ±0.002 db) (typ. ±0.002 db) Linearity (power) (CW +10 dbm to -60 dbm) (CW +10 dbm to -70 dbm) (CW +20 dbm to -60 dbm) at 23 C ±5 C <±0.025 db ±100 pw <±0.02 db ±5 pw <±0.02 db ±100 pw 1) For full specifications, and the test conditions, see the Technical Specifications p/n 5962-9321E 2) All optical heads have to be operated with the single (81618A) or dual (81619A) Interface Module.

Agilent Standard Source Modules 81650A 81651A 81652A 81654A (Fabry-Perot Laser) Center Wavelength 1310 nm 1550 nm 1550 nm/1625 nm 1310 nm/1550 nm ±15 nm ±15 nm ±15 nm ±15 nm Output Power Short term (15 min) CW power stability Long term (24 h) CW power stability CW power stability to back reflection (RL 14 db) Compact Tunable Laser Source Module Wavelength Range Output Power Power Stability Signal to Source Spontaneous Emission Ratio (typ.) Wavelength Repeatability Wavelength Stability (typ., 24h) 81689A 1525 nm to 1575 nm +6 dbm ±0.03 db 39 db/nm ±0.05 nm <±0.02 nm >0 dbm <±0.005 db typ <±0.003 db with coherence control active typ ±0.03 db typ ±0.003 db Agilent High Power Source Modules 81655A 81656A 81657A (Fabry-Perot Laser) Center Wavelength 1310 nm ±15 nm 1550 nm ±15 nm 1310 nm/1550 nm ±15 nm Output Power Short term (15 min) CW power stability Long term (24 h) CW power stability CW power stability to back reflection (RL 14 db) >+13 dbm <±0.005 db typ <±0.003 db with coherence control active typ ±0.03 db typ ±0.003 db Bandwidth High Bandwidth

High Bandwidth Connection to Test Devices The 8163A Lightwave Multimeter supports a wide range of fiber connectors. For details please refer to the 8163A Configuration Guide. This gives information on the connector interfaces and bare fiber adapters for use with these modules, as well as the filter holders, filters, lenses and connector adapters required for the optical heads. Ordering Information The 8163A Mainframe has two slots for any combination of the modules listed in this document, or modules of the 8153A Lightwave Multimeter series. Agilent 8163A Lightwave Multimeter Stimulus Response Solution Connector interfaces should also be ordered for each input and output, as well as any bare fiber adapters you require. If you want to use optical heads, you also need an interface module 81618A (single) or 81619A (dual) and you may need filter holders, filters, lenses and connector adapters. DWDM Working together should be a standard.