User s Guide CGETF10xx-1xx Slide-in-Module Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

Similar documents
User s Guide TN-J48xxx HP Compatible Small Form Factor Pluggables (SFPs) Transceiver Module

User s Guide SGETF10xx-1xx Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

User s Guide CSETF10xx-205 Slide-in-Module Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

User s Guide C3110: Gigabit Ethernet Copper & Fiber Ports 1000Base-T to 1000Base-SX/LX Connectivity

User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

USER S GUIDE CRS4Fxxxx-10x Slide-in-Module Media Converter RS485/422 Copper to Fiber

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode

User s Guide J/GE-CF-01(SX) Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

User s Guide CRS2F31xx-100 Slide-in-Module Media Converter RS-232 to Fiber

User s Guide SSETF10xx-205 Stand-Alone Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

User s Guide CETTF * Slide-in-Module Media Converter Ethernet Copper to Fiber 10Base-T to 10Base-FL

User s Guide SGETF10xx-10x Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

Port 2 - Duplex Fiber-Optic. 10/100/1000-Base-TX SGFEB

USER S GUIDE SRS4Fxxxx-10x Stand-Alone Media Converter RS485/422 Copper to Fiber

USER S GUIDE SRS4Fxxxx-10x Stand-Alone Media Converter RS485/422 Copper to Fiber

User s Guide J/RS232-xx-01 Stand-Alone Media Converter Just Convert-It RS-232 to Fiber

USER S GUIDE NEC-FXE-xx-01, 100Base-FX Express Card

User s Guide M/E-ISW-FX-01(xxx) Series Stand-Alone Industrial Media Converters Copper to Fiber 10/100Base-TX to 100Base-FX

User s Guide SRS2F Stand-Alone Media Converter RS-232 to Fiber

Standard Temperature Models: media converters that can be used in a standard temperature environment from 0 C to 50 C (32 F to 122 F)

33415 Rev. B Page 1 of 22

User s Guide E-100BTX-FX-05(XLW) Stand-Alone Media Converter Fast Ethernet Copper to Fiber 100Base-TX to 100Base-FX Extended Temperature

J/POE-CF-01 User s Guide

E-100BTX-FX-05 IN THE NETWORK

USER S GUIDE N-FXE-xxx-02, 100Base-FX Fiber Adaptor NIC Cards

M/E ISW FX 01 Series. User Guide. Contents. Introduction

User s Guide SPSVT26xx-10x Stand Alone Device High-Speed Serial V.35/X.21/RS449/RS530/RS232 Copper to Fiber

SVIDF201x-100. SVIDF201x-110

Part Number Port One - Copper Port Two - Duplex Fiber-Optic CSDTF ST, 850 nm multimode 2 km (1.2 miles)* CSDTF RJ-45 RJ-45

SPOEB10xx-100 User s Guide

User s Guide SBFTF10xx-10x Stand Alone Media Converter Copper to Fiber 10/100 Bridging (2 Ports) 10/100Base-TX to 100Base-FX

T1/E1 Twisted-Pair Copper to Fiber Media Converters USER S GUIDE COMPLIANCE INFORMATION. SSDTF10xx*-100

USER S GUIDE NEC-GXE-xx Base-X Fiber ExpressCard

M/E ISW FX 02 Series. Industrial Stand Alone Media Converters User Guide. Table of Contents

ST, 850 nm multimode 2 km (1.2 miles)* SSDTF RJ-45. ST, 1310 nm single mode 8 km (4.8 miles)* SSDTF RJ km (5,000 feet) *

Compliance Information

User Guide SBFTF10xx-1xx Stand-Alone Media Converters

User s Guide CMEFG10xx-1xx - Slide-in-Module SMEFG10xx-1xx - Stand-Alone Media Converters

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

M/GE-ISW-xx-01 User Guide. Contents. Introduction. Hardened Mini Gigabit Stand-Alone Media Converters

CAPTF33xx-1xx POTS to Fiber Optic Slide-In Card (SIC) User s Guide

Perle Fast Ethernet Media Converters

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Perle Fast Ethernet Media Converters

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

User Guide CPSVT26xx-10x Slide-in-Module Device

Small Form-Factor Pluggable (SFP) Module Installation Guide

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

FIBER OPTIC A/B SWITCH (Non-latching)

Synchronous Fiber Optic Modem

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

2-Port Hub Type 1 2-Port Hub Type 3 Unshielded 2-Port Hub Type 3 Shielded

User Guide. TN-QSFP-40G-xx Cisco Compatible 40G QSFP+ Contents. Introduction

CrystalView DVI Micro-DL Extender

Fibre Optic Modem ODW-622

E3/DS3 Fibre Extender

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Single mode 9/125µm, duplex

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

Ethernet Media Converters

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

ODW-621. RS-232 Point-to-point applications

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

RS-232 Line Booster SERIAL CABLE BOOSTER CHASSIS GROUND TX DATA RX DATA RTS CTS DSR SIGNAL GROUND

Fibre Optic Modem ODW-611

HD-One DX/DX500 HDMI Extender

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

OptEnet OC48 Regenerator Module User Manual

43-MILLIMETER COMPATIBLE SWIPE READER TECHNICAL REFERENCE MANUAL

Copyright Black Box Corporation. All rights reserved.

Product Operation Manual

twister Mbps TX-to-FX Media Converter

4 Wiring Brochure Wiring and installation of specific control

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

IEC G-port Gigabit smart rackmount Ethernet switches STAT PWR1 PWR2 FAULT FDX/HDX MODE. Warranty

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

opengear OPG-1L 50 MHz-2.3 GHz

100-MILLIMETER COMPATIBLE SWIPE READER TECHNICAL REFERENCE MANUAL

Owner s Manual. 10/100 Media Converters. Models: N SC-MM (850nm), N SC-15 (1310nm) 10/100/1000 Media Converters

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

TC3301. User's Manual

twister Mbps Multimode-to-Singlemode Media Converter

LONWORKS Fibre Optic Converter

I N S T R U C T I O N D A T A

USB-0100TX USB Fast Ethernet Converter. User s Guide

TOURNAMENT NOISE CANCELLING MICROPHONE*

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

RGBS Video Splitters MARCH 1994 AC063A AC063AE AC064A AC064AE AC065A AC065AE AC066A AC066AE

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

Fibre optic router for TP/FT-10 LRW-112PP

EDS-G205-1GTXSFP/G308 Series

Sync Genlock JULY 1993 AC083A. Sync Genlock

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Transcription:

User s Guide CGETF10xx-1xx Slide-in-Module Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX Transition Networks CGETF10xx-1xx Gigabit Ethernet media converter connects 1000Base-T shielded or unshielded twisted-pair copper cable to 1000Base-SX or 1000Base-LX, fiber-optic cable. The CGETF10xx-1xx is designed to be installed in the Transition Networks PointSystem chassis. Part Number Port One - Copper Port Two - Duplex Fiber-Optic CGETF1013-110 SC, 1000Base-SX, 850 nm multimode 220 m (721 ft)* (62.5/125 μm cable) 550 m (1,804 ft)* (50/125 μm cable) CGETF1014-110 CGETF1015-110 CGETF1017-110 CGETF1024-110 CGETF1035-110 SC, 1000Base-LX, 1310 nm single mode 10 km (6.2 miles)* SC, 1000Base-LX, 1310 nm single mode 25 km (15.5 miles)* SC, 1000Base-LX, 1550 nm single mode 65 km (40.4 miles)* SC, 1000Base-SX, 1310 nm extended multimode, 2 km (1.2 miles)* Note: 62.5/125 μm (fiber only) SC, 1000Base-LX, 1550 nm single mode 125 km (77.5 miles)* *Typical maximum cable distance. Actual distance is dependent upon the physical characteristics of the network installation. Note: The stand-alone version of the media converter is SGETF10xx-1xx. For more information, see the SGETF10xx-1xx user s guide on-line at: www.transition.com. Installation..................4 Operation...................7 Diagnostic Monitoring Interface (DMI).....................10 Cable Specifications..........11 Technical Specifications.......13 Troubleshooting.............14 Contact Us.................15 Compliance Information.......16

Part Number Port One - Copper Port Two - Single Fiber-Optic CGETF1040-110 SFP slots, see page 3 for SFP options. CGETF1029-110 CGETF1029-111 CGETF1029-112 CGETF1029-113 CGETF1029-116 CGETF1029-117 SC, 1000Base-LX, 1310 TX/1550 RX single mode, 20 km (12.4 miles)* SC, 1000Base-LX, 1550 TX/1310 RX single mode, 20 km (12.4 miles)* The CGETF1029-110 and the CGETF1029-111 are to be installed in the same network, where one is the local converter and the other is the remote converter. SC, 1000Base-LX, 1310 TX/1550 RX single mode, 40 km (24.8 miles)* SC, 1000Base-LX, 1550 TX/1310 RX single mode, 40 km (24.8 miles)* SC, 1000Base-LX, 1510 TX/1590 RX single mode, 80 km (49.7 miles)* SC, 1000Base-LX, 1590 TX/1510 RX single mode, 80 km (49.7 miles)* The CGETF1029-112 and the CGETF1029-113 are to be installed in the same network, where one is the local converter and the other is the remote converter. DMI Models (-1xx) The Diagnostic Monitoring Interface (DMI) models (listed below) allow diagnosing problems within the network. These devices have four functions: Transmit power Receive power Transmit bias current Temperature Within each function, the device will send a trap; i.e., error whenever a high or low warning event, or high or low alarm event occurs (for a total of 16 traps). In addition, if both the local and remote media converters are DMI models, the device will distinguish whether the trap event is from a local or a remote device. Part Number CGETF1040-110 Port One - Copper 1000-Base-TX RJ-45 100 m (328 ft) DMI Supported SFPs Sold separately, the following DMI supported SFP transceiver modules for port two are compatible with the CGETF1040-1xx converter and are available from Transition Networks. CGETF1040-110 Port Two - Fiber-Optic 1000Base-SX/LX TN-SFP-SX LC, 1000Base-SX, 850 nm multimode, 220-550 mm (720-1804 ft)* Without DMI TN-SFP-SXD LC, 1000Base-SX, 850 nm multimode, 220-550 mm (720-1804 ft)* TN-SFP-LX1 LC, 1000Base-LX, 1310 nm single mode, 10 km (6.2 miles)* TN-SFP-LX3 LC, 1000Base-LX, 1310 nm single mode, 30 km (18.8 miles)* TN-SFP-LX5 TN-SFP-LX8 TN-SFP-LX12 LC, 1000Base-LX, 1550 nm single mode, 50 km (31.2 miles)* LC, 1000Base-LX, 1550 nm single mode, 80 km (50.0 miles)* LC, 1000Base-LX, 1550 nm single mode, 120 km (74.6miles)* *Typical maximum cable distance. Actual distance is dependent upon the physical characteristics of the network. Note: Third-party Multi-Source Agreement (MSA) compliant Small Form Factor Pluggables (SFPs) can also be used in the CGETF1040-11x. 2 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 3

Installation CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the jumper, the 6-position switch, and installing the CGETF10xx-10x media converter into the PointSystem chassis. Failure to observe this caution could result in damage to the media converter. Set the 2-position jumper The jumper is located on the media converter circuit board, connector J5. Use a small needle-nosed pliers or similar device to set the jumper. Refer to the illustration on the right for hardware/software jumper positioning. Hardware Software The media converter s mode of operation is determined by the 6-position switch settings. Default is the Hardware position. The media converter s mode of operation is determined by the most recently saved onboard microprocessor settings. Set the 6-position switch The 6-position switch is located on the side of the media converter. Use a small flat-blade screwdriver to set the DIP switches. All switches are shown in the default position, UP. Note: Switch positions S2 and S3 function together to configure the media converter for Pause conditions. S1 Remote-Fault Detection up Disabled down Enable S2 & S3 work in combination Pause 10 sw position 2 up and 3 down: Symmetric 01 sw position 2 down and 3 up: Asymmetric 11 sw positions 2 and 3 up: Pause is OFF (default position) 00 sw positions 2 and 3 down: Symmetric and Asymmetric S4 Transparent Link Pass-Through up Enable Link Pass-Through down Disable Link Pass-Through H H Hardware Mode Software Mode 1. Remote Fiber Fault Detect 2. Pause (symmetric) 3. Pause (asymmetric) 4. Transparent Link Pass-Through 5. Auto-Negotiation 6. Loop Back S S Installation -- Continued Set the 6-position switch -- continued S5 S6 Fiber Auto-Negotiation up Disable Auto-Negotiation for the fiber link (default setting) down Enable Auto-Negotiation for the fiber link Loop Back up Disable RX/TX signal loop back (default setting) down Enable RX/TX signal loop back Install Mode During installation, set DIP switch 4 DOWN; leave all other switches in the UP position (default). This disables Transparent Link Pass-Through and Auto- Negotiation, allowing individual copper and fiber links to be established (both copper port LEDs will turn ON with each device-to-device connection) independent of having a complete end-to-end connection. Operation Mode After installation is complete (all copper and fiber ports connected and linked), set all switches to the UP position (default). Remote Fiber Fault Detect Remote fiber fault detect (RFD) monitors the status of the fiber link. Enable RFD in the remote converter only. CAUTION: If RFD is enabled in the device at each end of the link, a link passthrough event will put the converters into an unrecoverable state (unable to establish a link). Fiber Auto-Negotiation Fiber Auto-Negotiation allows the fiber interface to detect and then advertise the supported features of the remote device active only when a fiber cable is connected to a device with a negotiating port. The process is as follows: 1. The fiber interface detects the supported features of the remote partner. 2. These abilities are passed to the twisted-pair interface and advertised. 3. Once the twisted-pair interface has a link at the highest common capability, it passes the result to the fiber interface. 4. The fiber interfaces then start advertising these capabilities. At this point, the link between the fiber and the negotiating port is complete. If the CGETF10xx-1xx is connected via fiber to another CGETF10xx-1xx, both media converters must have the Fiber Auto-Negotiation setting disabled (switch 5 UP). Note: Transparent Link Pass-Through (switch position 4 enabled) cannot be turned OFF (disabled) when Fiber Auto-Negotiation is ON (enabled). 4 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 5

Installation -- Continued Install the slide-in-module IMPORTANT: Slots in the PointSystem chassis without a slide-in-module installed MUST have a protective plate covering the empty slot for Class A compliance. To install the CGETF10xx-1xx media converter slide-in-module: 1. Locate an empty slot on the PointSystem chassis. 2. Carefully slide the slide-in-module into the slot, aligning it with the slot guides. 3. Ensure that the slide-in-module is firmly seated inside the chassis. 4. Push in and rotate the panel fastener screw shown below clockwise to secure the module to the chassis front. Installation -- Continued Install the copper cable 1. Locate a 1000Base-T compliant copper cables with male, RJ-45 connectors installed at both ends. 2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the CGETF10xx-1xx media converter. 3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (switch, workstation, etc.). Point System Chassis Point System Chassis Panel Fastener RJ-45 Port Media Converter RJ-45 Port On other device (workstation, switch, etc.) Install the fiber cable Slot Media Converter 1. Locate a 1000Base-SX/LX compliant fiber cable with male, two-stranded TX to RX connectors installed at both ends. 2. Connect the fiber cable to the CGETF10xx-1xx media converter as described: Connect the male TX cable connector to the female TX port. Connect the male RX cable connector to the female RX port. 3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described: Connect the male TX cable connector to the female RX port. Connect the male RX cable connector to the female TX port. RX TX RX TX Operation Status LEDs Use the status LEDs to monitor the CGETF10xx-1xx media converter operation in the network. PWR (Power) ON = Connected to external AC power. LKF (Fiber link) ON = Fiber Connection RXC (Copper receive) Flashing = Receiving data on the copper link. ON = Copper Link connection Duplex ON = Full RXC LED LKF PWR TX 1000Base-X 1000Base-T RX Device Device Duplex LED 6 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 7

Operation -- Continued Remote-Fault Detect (RFD) Remote-Fault Detect monitors the status of the fiber link. When enabled, remote fault detection turns off the converter s fiber transmission when the fiber receiver goes down. RFD should only be enabled in the remote converter; if enabled in both, a link pass-through event will cause an unrecoverable condition between the converters. Pause The pause feature can improve network performance by allowing one end of the link to signal the other to discontinue frame transmission for a set period of time to relieve buffer congestion. The pause feature can be set to one of four settings: Disable (i.e., no pause) Symmetrical pause Asymmetric TX (transmit) pause Asymmetric RX (receive) pause Enable the pause feature if it is present on ALL network devices attached to the media converter(s); otherwise, disable this feature. Link Pass-Through The Link Pass-Through feature allows the media converter to monitor both the fiber and copper RX (receive) ports for loss of signal. Refer to the illustration below. For example, in the event of a loss of an RX signal (1), the media converter will automatically disable the fiber TX (transmit) signal (2), thus, passing through the link loss (3). The far-end device is automatically notified of the link loss (4), which prevents the loss of valuable data unknowingly transmitted over an invalid link. Near-End Device 1 original fault on the copper link media converter A disables the fiber TX link Media Converter A AutoCross (always on) 2 media converter B loses the fiber RX link Media Converter B The AutoCross feature allows either straight-through (MDI) or crossover (MDI-X) cables to be used when connecting to 10Base-T, 100Base-TX, or 1000Base-T devices, such as hubs, transceivers, or network interface cards (NICs). AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up to its companion device regardless of the cable configuration. 3 4 Far-End Device media converter B disables the copper link Operation -- Continued Transparent Link Pass-Through Transparent Link Pass-Through operates similar to Link Pass-Through with one exception: the fiber link between the converters remains active. A signal is passed through to the remote converter, causing it to shutdown the copper link, notifying the end device of the link failure. Auto-Negotiation Auto-Negotiation enables automatic configuration to achieve the best possible mode of operation over a link between devices. A device with this feature enabled will broadcast its speed (10Mbs, 100Mbs, etc.) and duplex (half/full) capabilities to another device with this feature, then negotiate the best mode of operation between them no user intervention required. Fiber Auto-Negotiation Fiber Auto-Negotiation allows the fiber interface to detect and then advertise the support capabilities of the remote device. This only occurs when a fiber cable is connected to a device with a negotiating port. Loop Back This diagnostic feature enables the media converter to loop back the signal from the RX port to the TX port for testing and troubleshooting purposes. Test signals from a bit-error test unit can then be inserted into either the copper or fiber link to test a particular segment. This type of diagnostic test can only be performed from the local to the remote device with loop back enabled on the remote device. SNMP Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring: Copper and fiber link/receive status Hardware switch settings Receive error count Also, use SNMP to enter network commands that: Enable/disable Remote Fault Fiber Detection Enable/disable Link Pass-Through Enable/disable Auto-Negotiation Symmetric pause Asymmetric TX (transmit) pause Asymmetric RX (receive) pause Disable pause See the on-line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage. 8 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 9

Diagnostic Monitoring Interface (DMI) The following DMI port screen and explanation table contains brief definitions of the DMI support offered on Transition Networks SFP optical interfaces. For further information, please see the help option on the CPSMM-xxx SNMP agent or Focal Point GUI. Variable Name Description DMI Rx Power Measured Receive optical power in microwatts and in decibels relative to 1mW. DMI Rx Power Alarm Alarm status of measured Receive optical power. DMI Temp Internally measured temperature of transceiver in degrees C and degrees F. DMI Temp Alarm Alarm status for internally measured temperature of transceiver. DMI Bias Current Measured transmit bias current in microamperes. DMI Bias Alarm Alarm status for measured transmit bias current for the interface. DMI Tx Power Measured transmit power, in microwatts and in decibels relative to 1mW.. DMI Tx Power Alarm Alarm status of measured transmit power. Rx Power Intrusion Threshold Instructs the converter to stop passing traffic when the receive power drops below the new threshold. This feature is sometimes referred to as 'Intrusion Detection, since tapping into a fiber to intercept traffic leads to a reduction in receive power. This value can be entered in microwatts or in decibels relative to 1mW. Cable Specifications The physical characteristics must meet or exceed IEEE 802.3 specifications. Fiber cable Bit Error Rate: <10-9 Single mode fiber (recommended): 9 μm Multimode fiber (recommended): 62.5/125 μm Multimode fiber (optional): 100/140, 85/140, 50/125 μm CGETF1013-110 850 nm multimode Fiber Optic Transmitter Power: min: -10.0 dbm max: -4.0 dbm Fiber Optic Receiver Sensitivity: min: -17.0 dbm max: 0.0 dbm 7.0 db CGETF1014-110 1310 nm single mode Fiber-optic Transmitter Power: min: -9.5 dbm max: -3.0 dbm Fiber-optic Receiver Sensitivity: min: -20.0 dbm max: -3.0 dbm 10.5 db CGETF1015-110 1310 nm single mode Fiber-optic Transmitter Power: min: -5.0 dbm max: -0.0 dbm Fiber-optic Receiver Sensitivity: min: -24.0 dbm max: -3.0 dbm 19.0 db CGETF1017-110 1550 nm single mode Fiber-optic Transmitter Power: min: -3.0 dbm max: 2.0 dbm Fiber-optic Receiver Sensitivity: min: -24.0 dbm max: -3.0 dbm 21.0 db CGETF1024-110 1300 nm extended multimode Fiber-optic Transmitter Power: min: -10.0 dbm max: -3.0 dbm Fiber-optic Receiver Sensitivity: min: -17.0 dbm max: -3.0 dbm 7.0 db CGETF1035-110 1550 nm single mode Fiber-optic Transmitter Power: min: 0.0 dbm max: 5.0 dbm Fiber-optic Receiver Sensitivity: min: -27.0 dbm max: -3.0 dbm 27.0 db CGETF1029-110 1310nm TX / 1550nm RX single mode CGETF1029-111 1550nm TX / 1310nm RX single mode Fiber-optic Transmitter Power: min: -8.0 dbm max: -3.0 dbm Fiber-optic Receiver Sensitivity: min: -21.0 dbm max: -3.0 dbm 13.0 db Note: This feature is not available on all devices. 10 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 11

Cable Specifications -- Continued Fiber cable - Continued CGETF1029-112 1310nm TX / 1550nm RX single mode CGETF1029-113 1550nm TX / 1310nm RX single mode Fiber-optic Transmitter Power: min: -3.0 dbm max: +2.0 dbm Fiber-optic Receiver Sensitivity: min: -23.0 dbm max: -3.0 dbm 20.0 db CGETF1029-116 1510nm TX / 1590nm RX single mode CGETF1029-117 1590nm TX / 1510nm RX single mode Fiber-optic Transmitter Power: min: -2.0 dbm max: +3.0 dbm Fiber-optic Receiver Sensitivity: min: -26.0 dbm max: -3.0 dbm 24.0 db Copper cable (Category 5 -- minimum requirement) Gauge = 24 to 22 AWG; Attenuation = 22.0 db /100m @ 100 MHz Straight-through OR crossover cable may be used. Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a gigabit network. Use only dedicated wire pairs for the active pins; e.g., blue/white & white/blue, orange/white & white/orange, etc. Do not use flat or silver satin wire. Technical Specifications For Transition Networks Model CGETF10xx-1xx or equivalent Standards: IEEE 802.3ab, IEEE 802.3 2000 Data Rate / Delay: 1000 Mbs/300 nsec Dimensions: 3.4" x 1.0" x 5.0" (86mm x 25mm x 127mm) Weight: 3 oz. (91 g) approximately Power Consumption: 5.4W 450mA @ 12VDC Packet Size: 10 Kbytes (maximum) MTBF* 381,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F) 1,344,000 hours (Bellcore7 V5.0) Operating Temp: Tmar** 0 C to 50 C (32 F to 122 F) Storage Temp: -15 C to 65 C (5 F to 149 F) Humidity: 10% to 90%, non condensing Altitude: 0 to 10,000 feet Warranty: Lifetime *MTBF is estimated using the predictability method. This method is based on MIL-217F at 25 C ambient temperature, typical enclosure heat rise of 10 C, and nominal operating conditions and parameters. Installation and configuration specific MTBF estimates are available upon request. Contact Technical Support. **Manufacturer s rated ambient temperature. For the most up-to-date information on the CGETF10xx-1xx media converter, view the user s guide on-line at: www.transition.com. The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC- 825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11. WARNING: Visible and invisible laser radiation when open. Do not stare into the beam or view the beam directly with optical instruments. Failure to observe this warning could result in an eye injury or blindness. WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure. IMPORTANT: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-building (inside plant) link segments that are not subject to lightening transients or power faults. Copperbased media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-building (outside plant) link segments that are subject to lightening transients or power faults. 12 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 13

Troubleshooting If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action: 1. Is the PWR (power) LED illuminated? NO Is the media converter inserted properly into the chassis? Is the power cord installed properly in the chassis and at the external power source and does the external power source provide power? YES Proceed to step 2. 2. Is the RXC (copper link) LED illuminated? NO Check the twisted-pair copper cables for proper connection. YES Proceed to step 3. 3. Is the LKF (fiber link) LED illuminated? NO Check the fiber cables for proper connection. Verify that the TX and RX cables on the media converter are connected to the RX and TX ports, respectively, on the other device. If the converter is connected to another xgetf10xx-11x via fiber, make sure that the Auto-Negotiation (DIP switch 5) is disabled (UP) in hardware mode, or disabled via software in software mode. YES Proceed to step 4. 4. Is the RXC (copper receive) LED flashing? NO If there is activity on the 1000Base-T port, disconnect and reconnect the twisted-pair copper cable to restart the initialization process. Restart the workstation to restart the initialization process. YES Contact Us Technical support Technical support is available 24-hours a day US and Canada: 1-800-260-1312 International: 00-1-952-941-7600 Transition now Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link. Web-based seminars Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link. E-Mail Ask a question anytime by sending an e-mail to our technical support staff. techsupport@transition.com Address Transition Networks 10900 Red Circle Drive Minnetonka, MN 55343, U.S.A. telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322 Declaration of Conformity Name of Mfg: Transition Networks 10900 City West Parkway, Minnetonka MN 55343 U.S.A. Model: CGETF10xx-1xx Series Media Converters Part Number(s): CGETF1013-110, CGETF1014-110, CGETF1015-110, CGETF1017-110, CGETF1018-110, CGETF1024-110, CGETF1035-110, CGETF1040-110, CGETF1029-110, CGETF1029-111, CGETF1029-112, CGETF1029-113, CGETF1029-116, CGETF1029-117 Regulation: EMC Directive 89/336/EEC Purpose: To declare that the CGETF10xx-1xx to which this declaration refers is in conformity with the following standards: EN 55022:1994 + A1:1995 + A1:1997; EN 55024:1998 + Al:2001 + A2:2003 I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Stephen Anderson, Vice-President of Engineering June, 2008 Date 14 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 15

Compliance Information CE Mark FCC regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense. Canadian regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. European regulations Warning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll is der Benutzer für Gegenmaßnahmen verantwortlich. Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées. In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document. CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network. Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG- Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität. Trademark notice All trademarks and registered trademarks are the property of their respective owners. Copyright restrictions 2003-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical - without written permission from Transition Networks. 16 Printed in the U.S.A. 33333.E