3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 RRAINREPWH RR2 ain Repeater Lutron Catalog Number anufacturer Description Weight per unit Product Category RRAINREPWH Lutron Radiora 2 Enhancement and Interface, 20V ain Repeater With Astronomic Timeclock, and Ports.0 (lbs/each) Lighting Controls Features amperage rating 0.95@20 V/0.47@240V/0.4@277V Ballast Factor.7 in Frequency Range 43.0 Hz to 437.0 Hz or 868.25 Hz to 869.850 Hz input DC/300 ma Lamp Type T8/U-Bend fluorescent aterial PLASTIC inimum Starting Temperature 0 degrees Celsius Number of Lamps 3 in Factor Greater than or equal to 0.95 start type Programmed rapid Voltage Rating DC/300 ma Wattage SVX007A-4ABB9C7D3 aterial, Color, and Finish Color Dimensions and Weight Height Length Width Descriptions Description Long Description Product Type special features WHITE.06 in 5.25 in (33.4 mm) 4.25 in RR2 AIN REPEATER RadioRA 2 Enhancement and Interface, 20V main repeater with astronomic timeclock, and ethernet ports RADIORA2 ain Repeater Extend the range of Radio Frequency () signals that are sent between devices. Ensure error-free communication between system components and prevent interference from neighboring systems. Repeater has an range of 30 ft (9 m).
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 anufacturer Information Brand Lutron GTIN 00027557774659 anufacturers Part Number RR-AIN-REP-WH sub brand RadioRA2 UPC 027557774659 Taxonomies, Classifications, and Categories Category Description All Data Type Repeater, main Packaging Carton Package 24 Weight Per each Uses, Certifications, and Standards Application Enclosure environmental conditions Frequency Rating ounting Operating Temperature standard Temperature Rating LIGHTING CONTROL Plastic 0% to 90% humidity, non-condensing. Indoor use only. 50/60 HZ WALLBOX 0-40 C UL, CSA, Class P thermal protected, ANSI, FCC 0 to 40 degrees Celsius
RadioRA 2 Repeaters extend the range of Radio Frequency () signals that are sent between devices. Repeaters ensure error-free communication between system components and prevent interference from neighboring systems. For systems that extend up to 30 ft (9 m), one () ain Repeater is required to set up the system. Up to four (4) Auxiliary Repeaters can be added to extend the range for larger system applications. Each Repeater has an range of 30 ft (9 m), covering a total area of approximately 2500 ft 2 (232 m 2 ). product specifications 369227f 02.9.4 ain Repeater odels odel Number* Repeater Type Frequency Antenna Length Region RR-AIN-REP-WH RR-AIN-REP-WHBA RR-AUX-REP-WH RR-AUX-REP-WHBA ain Auxiliary 434 Hz 6.25 in (58.8 mm) North America, Brazil (BA models only RRK-AIN-REP-WH RRK-AUX-REP-WH ain Auxiliary 868 Hz 3.3 in (79.4 mm) Europe * Available only in White (WH) Auxiliary Repeater Technical Support: 800.523.9466 (USA)
Specifications product specifications 369227f 02.9.4 odel Numbers Typical Consumption Regulatory Approvals Environment Low-Voltage Wire Type s ESD Protection Surge Protection Failure ounting Connections Warranty RR-AIN-REP-WH, RR-AIN-REP-WHBA, RR-AUX-REP-WH, RR-AUX-REP-WHBA, RRK-AIN-REP-WH, RRK-AUX-REP-WH ain / Auxiliary Repeater: - 300 ma See Low-Voltage Transformer spec (Lutron P/N 36956) ain Repeater: 3. W conditions: one LED on, cable plugged in, powered by the - adapter Auxiliary Repeater: 0.6 W conditions: one LED on, powered by the - adapter ain / Aux (-WH only): culus listed; FCC certified; Industry Canada certified; COFETEL certified; ASEP certified; Bermuda Department of Telecommunications type approval; CRC certified; INDOTEL certified; SUTEL certified ain / Aux (-WHBA only): ANATEL certified ain / Aux (RRK only): CE marked Adapter (T20-9DC-3-BL): culus listed; NO certified Ambient operating temperature: 32 F to 04 F (0 C to 40 C), 0% to 90% humidity, non-condensing. Indoor use only Two pairs: one pair 8 AWG (.0 mm 2 ), one pair 22 AWG to 8 AWG (0.5 mm 2 to.0 mm 2 ) twisted shielded IEC PELV/NEC Class 2 cable Repeaters communicate with the system through. All devices must be located within 30 ft (9 m) of a Repeater. All Repeaters must be within 60 ft (8 m) of another Repeater. System devices operate on frequencies between 43.0 Hz to 437.0 Hz or 868.25 Hz to 869.850 Hz ed to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 6000-4-2. ed to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.4-99 Recommended Practice on Surge Voltages in Low-Voltage AC Circuits failure memory: should power be interrupted, the Repeater will return to its previous state when power is restored ount on a wall, ceiling, or level surface using the two #6 (3) screws provided ain Repeater:, and RS485 /TechnicalDocumentLibrary/Warranty.pdf /TechnicalDocumentLibrary/Intl_Warranty.pdf Design Features button: enters the system diagnostic mode. Can be programmed from a PC. RS485 port to connect to other Repeaters through a wired link (daisy-chain). ain Repeaters allow configuration and integration to the system through or ports (see chart to the right). System with 2 ain Repeaters must be connected via. Configuration Integration P P P 2 Technical Support: 800.523.9466 (USA)
Dimensions All dimensions are shown as: in (mm) product specifications 369227f 02.9.4 Front View See table 0.63 (6) Side View ain Repeater ounting Hole Detail Diameter 0.9 (4.8) 0.23 (5.8) 5.25 (33.4) odel Diameter 0.3 (7.9) Antenna Dimension Integrate Program / Integrate 2.72 (70) RR-AIN-REP-WH RR-AIN-REP-WHBA RR-AUX-REP-WH RR-AUX-REP-WHBA 6.25 (58.8) CO ounting holes 3.75 (95.3) 6 (27) RRK-AIN-REP-WH RRK-AUX-REP-WH 3.3 (79.4) 4.25 (08) ounting Vertical Horizontal Ceiling Wall #6 (3) screw recommended (2 included) Level Surface 3 Technical Support: 800.523.9466 (USA)
Operation product specifications 369227f 02.9.4 ain Repeater CO Integrate Program / Integrate LEDs Display the status of the Repeaters in the system while in mode. and LEDs Display the Tx / Rx activity on the and wired links. (Green = Tx; Orange = Rx) and Buttons Press and hold to enter the system into mode or mode. and LEDs Flash green to indicate that the system is in mode or mode. and Configuration ain or Auxiliary Repeater 30 ft (9 m) maximum 30 ft (9 m) maximum Link (Daisy-chain) 000 ft (305 m) maximum IEC PELV / NEC Class 2 cable. Two pairs: one pair 8 AWG (.0 mm 2 ), one pair 22 AWG to 8 AWG (0.5 mm 2 to.0 mm 2 ) twisted shielded. Link 60 ft (8 m) maximum 4 Technical Support: 800.523.9466 (USA)
CO Integrate CO CO Program / Integrate CO Integrate Program / Integrate RadioRA 2 Repeaters Qualified Level 2 (L2) dealers/installers can upgrade their software to provide support for a 200 device system by enabling the addition of a second main repeater subnet to the system. product specifications 369227f 02.9.4 Using Two ain Repeaters for Qualified Dealers/Installers Only PC ain repeater subnet # ain ain Repeater Router/HUB/Switch 2 ain repeater subnet #2 ain ain Repeater Note: To learn how you can become a qualified L2 dealer/ installer, please contact your local Lutron representative. Auxiliary Auxiliary Auxiliary Repeater Auxiliary Repeater Optional 3 RS485 Dimmer Keypad Dimmer Keypad The two main repeaters must be connected by during and after PC programming. The two main repeaters do not communicate over the link. 2 The two main repeaters may be connected over by one of the following: a. Router b. HUB or switch (only if static IP addresses are being used) c. After PC programming is complete, direct connection without a router, HUB, or switch (only if static IP addresses are being used) 3 Auxiliary repeaters and main repeaters on the same subnet can be optionally connected by RS485 wired links when the repeater range is exceeded. a. The RS485 wired link cannot be connected between the two main repeater subnets b. The RS485 wired link cannot be connected between two main repeaters. c. RS485 wired links can be used between any combination of main and auxiliary repeaters on the same subnet. 5 Technical Support: 800.523.9466 (USA)
Connections ain Repeater product specifications 369227f 02.9.4 Top View range To Repeater: 60 ft (8 m) To other devices: 30 ft (9 m) Bottom View Jack (to adapter)* IEC PELV / NEC Class 2 Link (Daisy Chain) maximum 000 ft (305 m) GND Antenna 9V RS485 Cable maximum 50 ft (5 m) CAT5 Cable maximum 328 ft (00 m) and Pin Numbering 6 7 8 9 5 8765432 Pin # T D 2 R D 3 GND 5 Pin # T + Ve T Ve 2 R + Ve 3 R Ve 6 Auxiliary Repeater Top View range To Repeater: 60 ft (8 m) To other devices: 30 ft (9 m) Bottom View Jack (to adapter)* IEC PELV / NEC Class 2 Link (Daisy Chain) maximum 000 ft (305 m) GND Antenna 9V RS485 * See Low-Voltage Transformer spec (Lutron P/N 36956) 6 Technical Support: 800.523.9466 (USA)