Tube Roller Shakers. User Guide. Version 1.2

Similar documents
Tube Rotator. User Guide. Version 1.2

Advanced Digital Melting Point Apparatus

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer

EN - English Washington Street Melrose, MA Phone Toll Free Revision 4 20/06/17

OPERATING MANUAL. Cole-Parmer Stir-Pak. Mixer Head Model Numbers , , , , & Mixer Controller Model Numbers

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex

OPERATING MANUAL FIXED FLOW PUMP DRIVES

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

PT-C-HDADE. User Manual. HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model PT-C-HDADE. Designed in Germany

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

Orbit TM DIGITAL SHAKERS

HulaMixer Sample Mixer

MEISHU Phono INTEGRATED AMPLIFIER OWNER S INFORMATION

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

CONQUEROR STEREO POWER AMPLIFIER OWNER S INFORMATION

User Manual TL-2X1-HDV 2x1 HDMI & VGA Switcher All Rights Reserved Version: TL-2X1-HDV_160630

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

OTO Phono SE Signature

Instructions. P MHz 1X/10X Passive Probe

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

KHT 1000C HV-Probe Calibrator. Instruction Manual

3G/HD/SD-SDI to HDMI Converter

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

Thank you for purchasing SEIKO SHOOTING TIMER KT-401. Before using your SEIKO SHOOTING TIMER, please read this manual carefully for its proper use

DisplayPort to VGA Converter

8 Port HD/SD-SDI Switch

M2 RIAA PHONO STAGE OWNER S INFORMATION

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

BT Diverse Repeater. User Guide

1X4 HDMI Splitter with 3D Support

INSTRUCTION MANUAL PELLAR PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

.Power Distribution Center. PD-1. Instruction Manual

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

Magnetic Field Generator 1000

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

TRF STEP-DOWN TRANSFORMER USER MANUAL

Operation Manual VMS 3.0 Video System

PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

VK-P10SE WARRANTY REGISTRATION FORM

NS-3 RF Noise Source Operation Manual

Monochrome Video Monitors

/ PAT01 USER MANUAL

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

VGA to DVI Extender over Fiber SET

Owner Handbook. Jupiter Blackhole. LED UV Flood

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

Installation Manual Original Instructions - IW4001

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

FD Trinitron Colour Television

Vortex Mixers. Mini Vortex Mixers Heavy-Duty Vortex Mixers Microplate Vortex Mixers Multi-Tube Vortex Mixers. Asia Pacific

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

CVSB/ S-video/ HDMI to HDMI Scaler with 720p and 1080p Switching.

TVAC20000 User manual

INSTRUCTION MANUAL PULSUS PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

USERS MANUAL GR ONE 300 GR ONE 700 GR ONE 1400

English. User Manual sub8 Subwoofer SUBWOOFER. Supporting your digital lifestyle

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

DD624CS Hi-Def Video Circle & Cross Hair Overlay Generator. Users Manual. Colorado Video

Users Manual. Stroboscope. September 2014

Litile34 OPERATION MANUAL

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

ASP-FIBRS1 User Manual

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

Contents Introduction Safety Cleaning Connections Cartridge gain and loading Technical specification Fig.1 PS.30R/ PS.30RDT rear panel Fig.

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

Magnetic Stirrers Magnetic Stirr

VLHDMIEXTFIB_2017V1.0

Operating Manual. Mark Levinson Nº25 Dual Monaural Phono Preamplifier. Madrigal Audio Laboratories, Inc. 1

KRF EMC Filters Installation, Operation and Maintenance Manual

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

SCRIPT INNOVATIONS C- RAY PILL COUNTER OPERATORS MANUAL

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Power Injector 1520 Series

HD Digital MPEG2 Encoder / QAM Modulator

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0

AEQ TH-03 Digital Hybrid of 1 (TH-03.1) or 2 lines (TH-03.2) with Frequency Extender

Get Connected. Download the free Pure Connect app to immerse yourself in music.

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

TECHCONNECT TC-HDMIIP OWNERS MANUAL. TC-HDMIIP_manual_en.doc

10.4" LCD Monitor with Aluminum Front Bezel YPM1040PHB

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

VPM2. Operator's Manual

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

PRO Mixer Distro User Guide

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Transcription:

Tube Roller Shakers User Guide Version 1.2

Control panel Rollers Side retaining panels Analog models LED display Drip tray (not visible) Digital models Power On/Off and control dial Roller retaining panel Rear view (all models) Fig. 1: Front and rear views IEC power socket

Tube Roller Shakers Introduction Thank you for purchasing this Cole-Parmer product. To get the best performance from the equipment, and for your own safety, please read these instructions carefully before use. Before discarding the packaging check that all parts are present and correct. This equipment is designed to operate under the following conditions: For indoor use only Use in a well ventilated area Ambient temperature range 4 C to 60 C (39.2 F to 140 F) Altitude to 2000 m (6500 ft) Relative humidity not exceeding 80% Power supply fluctuation not exceeding 10% of nominal Overvoltage category II IEC60364-4-443 Pollution degree 2 IEC664 Use with a minimum distance all round of 200 mm (8 in.) from walls or other items If the equipment is not used in the manner described in this manual and with accessories other than those recommended by the manufacturer, the protection provided may be impaired. Electrical Installation THIS EQUIPMENT MUST BE GROUNDED Before connection please ensure that the line supply corresponds to that shown on the rating plate. Power requirements 120 V Models 230 V Models 04750-22 50 W 04750-20 50 W 04750-26 50 W 04750-24 50 W 04750-30 50 W 04750-28 50 W 04750-34 50 W 04750-32 50 W The 120 V Models are provided with a NEMA 5-15 plug. The 230 V Models are provided with a UK 3-pin and a Schuko 2-pin plug. Should the cable not be suitable for connecting to the power supply, replace the plug with a suitable alternative. THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN. NOTE: Refer to the equipment rating plate to ensure that the plug and fusing are suitable for the voltage and wattage stated. 3

The wires in the power cable (120 V) are colored as follows: BLACK - HOT/LIVE WHITE - NEUTRAL GREEN - EARTH The wires in the power cable (230 V) are colored as follows: BROWN - HOT/LIVE BLUE - NEUTRAL GREEN/YELLOW - EARTH IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN Should the power cable need replacing, a cable of 1 mm 2 of harmonized code H05W-F connected to an IEC320 plug should be used. The appropriate power cable should be connected BEFORE connection to the power supply. General Description The Cole-Parmer Tube Roller Shakers provide a gentle, but highly efficient, rocking and rolling action. The analog models rotate at a fixed speed of 33 rpm and rise and fall 16 mm. The digital models have adjustable speed control between 5 and 60 rpm, and an adjustable digital timer that automatically stops rotation after the set time (1 to 9999 minutes, 1 second to 90 minutes or 1 minute to 9 hours). Most sizes of vessel including Bijou bottles, Universal containers and other bottles can be accommodated. The Tube Roller Shaker is available in two sizes: 6 rollers for a space-saving footprint or 9 rollers for higher throughput. Individual rollers can be removed to allow mixing of larger vessels up to a maximum of 3 kg (6.5 lbs) total load. Removable side retaining panels prevent tubes rolling off the unit. A drip tray positioned beneath the rollers contains any spills which may occur. 04750-20 TUBE ROLLER SHAKER 6 ANALOG 220/230 V 50/60 HZ 04750-22 TUBE ROLLER SHAKER 6 ANALOG 120 V 50/60 HZ 04750-24 TUBE ROLLER SHAKER 6 DIGITAL 220/230 V 50/60 HZ 04750-26 TUBE ROLLER SHAKER 6 DIGITAL 120 V 50/60 HZ 04750-28 TUBE ROLLER SHAKER 9 ANALOG 220/230 V 50/60 HZ 04750-30 TUBE ROLLER SHAKER 9 ANALOG 120 V 50/60 HZ 04750-32 TUBE ROLLER SHAKER 9 DIGITAL 220/230 V 50/60 HZ 04750-34 TUBE ROLLER SHAKER 9 DIGITAL 120 V 50/60 HZ Available separately is a stacking kit (catalog number 04750-98) which allows up to two units to be stacked one on top of another, optimizing bench space; up to three units maximum can be stacked (requires two kits). Please visit the Cole-Parmer website www.coleparmer.com for further information. 4

Safety Advice Users should be aware of the following safety advice: The unit should be carried using both hands with the fingers under the side edges. NEVER move or carry the unit with containers on the top or while still connected to the power supply. DO NOT mix combustible liquids or use the equipment in hazardous atmospheres. In case of power interruption, a fault or mechanical failure, the unit will continue to operate on removal of fault. Mechanical energy can lead to breakage of glass vessels. Use with care. DO NOT position the unit such that it is difficult to disconnect it from the power by removing the power cable from the socket at the back. Operation Analog Models Fig. 2: Control panel for analog models. Position the tube roller shaker on a firm level surface and connect to the power supply. Place the samples to be mixed between the rollers. Once all the samples have been positioned, switch the tube roller shaker ON using the power On/Off switch. Digital Models Start/stop button Mode button rpm/time indicator Digital display Control dial Fig. 3: Control panel for digital models. Position the tube roller shaker on a firm level surface and connect to the power supply. Place the 5

samples to be mixed between the rollers. Once all the samples have been positioned, switch the tube roller shaker ON by pressing the control dial (see Fig. 3). The unit will carry out a self test routine and then the display will show the last stored set speed (red dot in the display shows RPM is selected). This can be adjusted by turning the control dial. Once the correct speed is displayed, press the start/stop button to begin motion. The speed can be adjusted without halting the unit. The unit can be halted at any time by pressing the start/stop button. Setting the Timer In order to use the timer press the mode button. The red dot on the display moves over to time. The display will show the last stored time in hours and minutes (H is displayed on the left hand side of digital display) or seconds and minutes depending on the timer unit selected (see the instructions below on how to change the timer unit). Select the desired count-down time using the control dial (--- indicates continuous, no timer set). When the display shows the correct time in minutes, press the start/stop button to begin operating. During operation, motion can be paused at any time by pressing the start/stop button. If the button is pressed again, motion will start again and the timer will continue to count down. The current timer or speed can be displayed or adjusted by using the mode button to toggle between the two and altered with the control dial, without halting the unit. When the timer reaches zero, the unit will be automatically halted and an alert will sound. Press the start/stop button to revert back to the saved time and speed values set (see instructions below to adjust saved values) or select new values following instructions given above. NOTE: To disable the timer and revert to continuous rotation, select - - - in the display during timer mode. To switch the unit OFF completely, press the control dial in. The display will show OFF. Saving Speed/Time Values In order to save a commonly used speed/time value, switch the unit ON by pressing the control dial in (see Fig. 3). Select both a speed value and a time value (either 1 to 9999 minutes, 1 second to 90 minutes or 1 minute to 9 hours or continuous - - -) using the instructions given above. Switch the unit OFF by pressing in the control dial. Wait 5 seconds and switch the unit back ON by pressing the control dial in. The input values are now saved in memory. They can be altered at any time by following the same procedure. NOTE: When the unit is switched OFF using the control dial, whatever values of speed/time were set prior to turning the unit off will be saved, and will be the values restored when the unit is switched back on. Changing the timer unit The unit timer is defaulted to minutes only (1 minute to 9999). To change to minutes and hours (1 minute to 9 hours, H is displayed in the left digit of the timer display), or to change to seconds and minutes (1 second to 90 minutes), turn the unit off using the control dial then switch the power off at the plug. Hold down both the start/stop button and the mode button while simultaneously 6

switching the power back on. The display will temporarily show 88:88 then OFF. Release the buttons. Using the control dial turn the unit on, the display will show nn:ss for minutes and seconds, H:nn for hours and minutes and nn for minutes. Turn the control dial to select the desired timer unit and then turn the unit off by pressing the control dial, OFF will be displayed. When the unit is next used the timer will have been altered to the set unit. Removing Individual Rollers Individual rollers can be removed to accommodate larger vessels. First, disconnect the power cable and remove the two side retaining panels by sliding upwards then pulling away from the unit (see Fig. 4). 1 2 Fig. 4: Removing the side retaining panels. Next pull the roller retaining panel upwards to remove (see Fig. 5). Fig. 5: Removing the roller retaining panel. 7

Select the roller(s) to be removed and push towards the front of the unit until the rear connector is free then lift out (see Fig. 6). 1 2 Fig. 6: Removing the roller. To replace a roller, locate the roller pin in the socket at the front of the unit, then push the connector back into the other end until it is secure. After removing or replacing rollers, replace the roller retaining panel and side retaining panels and reconnect the power cable.. Cleaning and Care WARNING: Ensure the unit is disconnected from the power supply before attempting maintenance or servicing. The unit should be cleaned using a damp cloth and a mild detergent solution. Cleaning is made easier if spillages are attended to promptly. In any case, spillages of acids and alkalies MUST be removed immediately as these chemicals can attack and damage the casework finish. Ensure that the appropriate safety precautions are observed. Accessories Stacking Kit 04750-98 Optimizes bench space by allowing up to two units to be stacked one on top of another; up to three units maximum can be stacked (requires two kits). Please visit the Cole-Parmer website www.coleparmer.com for further information. 8

Servicing and Repair This product range does not require any routine servicing. Note: There are no internal user replaceable parts. In the event of product failure it is recommended that any repair is only undertaken by suitably qualified personnel. For advice, please contact Cole-Parmer quoting the model and serial number. Only spare parts supplied by the manufacturer or its agent should be used. Fitting of non-approved parts may affect the performance of the safety features of the instrument. If in doubt, please contact Cole-Parmer. Warranty Cole-Parmer warrants this equipment to be free from defects in material and workmanship, when used under normal laboratory conditions, for a period of three (3) years. In the event of a justified claim, Cole-Parmer will replace any defective component or replace the unit free of charge. This warranty does NOT apply if: Any rollers have been damaged due to mechanical impact, scratching, chipping or chemical etching. Any repair has been made or attempted other than by the manufacturer or its agent. Any minor coating chips or scratches occur during normal use (i.e., wear and tear). Damage is caused by fire, accident, misuse, neglect, incorrect adjustment or repair, damage caused by installation, adaptation, modification or fitting of non-approved parts. 9

Technical Specification 120 V: 04750-22 120 V: 04750-26 120 V: 04750-30 120 V: 04750-34 230 V: 04750-20 230 V: 04750-24 230 V: 04750-28 230 V: 04750-32 Number of rollers 6 6 9 9 Speed 33 rpm 5 to 60 rpm 33 rpm 5 to 60 rpm Amplitude 16 mm (0.6 in.) 16 mm (0.6 in.) 16 mm (0.6 in.) 16 mm (0.6 in.) Maximum load 3 kg (6 lb) 3 kg (6 lb) 3 kg (6 lb) 3 kg (6 lb) Controls Analog Digital Analog Digital Timer No Yes No Yes Roller size 340x30 mm 340x30 mm 340x30 mm 340x30 mm (length x diameter) (13.4x1.2 in.) (13.4x1.2 in.) (13.4x1.2 in.) (13.4x1.2 in.) Overall dimensions 565x240x110 mm 565x240x110 mm 595x375x110 mm 595x375x110 mm (w x d x h) (22.2x9.4x4.3 in.) (22.2x9.4x4.3 in.) (23.4x14.75x4.3 in.) (23.4x14.75x4.3 in.) Net weight 5.6 kg (12.4 lb) 5.7 kg (12.5 lb) 7.5 kg (16.5 lb) 7.6 kg (16.8 lb) Electrical Supply 120 V, 50/60 Hz 120 V, 50/60 Hz 120 V, 50/60 Hz 120 V, 50/60 Hz or or or or 230 V, 50/60 Hz 230 V, 50/60 Hz 230 V, 50/60 Hz 230 V, 50/60 Hz 10

These products meet the relevant EC harmonized standards for radio frequency interference and may be expected not to interfere with, or be affected by, other equipment with similar qualifications. We cannot be sure that other equipment used in their vicinity will meet these standards and we cannot guarantee that interference will not occur in practice. Where there is a possibility that injury, damage or loss might occur if equipment malfunctions due to radio frequency interference, or for general advice before use, contact the manufacturer. Declaration of Conformity Catalog Number: Description: 04750-20 TUBE ROLLER SHAKER 6 ANALOG 220/230 V 50/60 HZ 04750-22 TUBE ROLLER SHAKER 6 ANALOG 120 V 50/60 HZ 04750-24 TUBE ROLLER SHAKER 6 DIGITAL 220/230 V 50/60 HZ 04750-26 TUBE ROLLER SHAKER 6 DIGITAL 120 V 50/60 HZ 04750-28 TUBE ROLLER SHAKER 9 ANALOG 220/230 V 50/60 HZ 04750-30 TUBE ROLLER SHAKER 9 ANALOG 120 V 50/60 HZ 04750-32 TUBE ROLLER SHAKER 9 DIGITAL 220/230 V 50/60 HZ 04750-34 TUBE ROLLER SHAKER 9 DIGITAL 120 V 50/60 HZ This product complies with the requirements of the EU Directives listed below: 2004/108/EC EMC Directive 2006/95/EC Low Voltage Directive (LVD) 2011/65/EC RoHs Directive

For technical, sales or servicing information, contact: Cole-Parmer 625 East Bunker Court Vernon Hills, IL 60061-1844 Toll-Free: 800-323-4340 Phone: 847-549-7600 Fax: 847-247-2929 www.coleparmer.com