Agilent M9362A-D01-F26 PXIe Quad Downconverter

Similar documents
Agilent M9361A PXI Downconverter

Agilent M9202A PXI-Express Wideband IF Digitizer

Agilent Series Harmonic Mixers

Exceptional performance

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Agilent N4876A 28 Gb/s Multiplexer 2:1

Keysight Technologies Achieve High-Quality Compliance Test Results Using A Top-Quality Test Fixture. Application Note

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Agilent Understanding the Agilent 34405A DMM Operation Application Note

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Keysight Technologies ad Integrated RF Test Solution

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details

Agilent N5183A MXG Microwave Signal Generator

Agilent 87405C 100 MHz to 18 GHz Preamplifier

FlexRay Physical Layer Eye-diagram Mask Testing

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

Keysight Technologies Segmented Memory Acquisition for InfiniiVision Series Oscilloscopes. Data Sheet

Keysight Technologies Millimeter Wave Frequency Extenders From Virginia Diodes Inc. for the Keysight X-Series Signal Analyzers. Technical Overview

Agilent N4876A 28 Gb/s Multiplexer 2:1

Agilent Series Preselected Millimeter Mixers

Logic Analysis Fundamentals

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

Agilent M9703A. Challenge the Boundaries of Test Agilent Modular Products. Data Sheet. AXIe High-Speed Digitizer/ Wideband Digital Receiver

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Instrumentation Grade RF & Microwave Subsystems

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

A Simple, Yet Powerful Method to Characterize Differential Interconnects

Keysight Technologies Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details. Application Note

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

PXI MICROWAVE. Model PXI-1420

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

Selecting the Right Oscilloscope for Protocol Analysis Applications

CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes

Keysight Technologies

Wideband Downconverters With Signatec 14-Bit Digitizers

Electrical Sampling Modules

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

Low Cost, High Speed Spectrum Analyzers For RF Manufacturing APPLICATION NOTE

Agilent Modular Instrumentation

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

Agilent 87075C Multiport Test Set Product Overview

Keysight N1085A PAM-4 Measurement Application For 86100D DCA-X Series Oscilloscopes. Data Sheet

Wideband Downconverter Solutions

46 GBaud Multi-Format Optical Transmitter

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

Keysight Technologies N5998A HDMI Protocol/Audio/Video Analyzer and Generator

Time-Saving Features in Economy Oscilloscopes Streamline Test

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

RF Semiconductor Test AXRF RF Port Upgrade Kits

Keysight Technologies RS-232/UART Triggering and Hardware-Based Decode (N5457A) for InfiniiVision Oscilloscopes

Agilent N4965A Multi-Channel BERT 12.5 Gb/s Data Sheet

STEVAL-ILL015V1. High brightness RGB LED array with LED error detection based on the STP24DP05 and STM32. Features. Description

Tektronix Logic Analyzer Probes P6900 Series Datasheet for DDR Memory Applications

Keysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution

Automated Limit Testing

Keysight Technologies Decoding Automotive Key Fob Communication based on Manchester-encoded ASK Modulation

Obsolete Product(s) - Obsolete Product(s)

Keysight Technologies

Keysight E4729A SystemVue Consulting Services

Agilent Technologies N5454A Segmented Memory Acquisition for Agilent InfiniiVision Series Oscilloscopes

R&S ZN-Z85 Switch Matrix Specifications

Keysight Technologies U3801A/02A IoT Fundamentals Applied Courseware. Data Sheet

USB Smart Power Sensor

USB Smart Power Sensor

Optical Sampling Modules 80C01 80C02 80C07B 80C08C 80C10 80C11 80C12

Agilent V3500A Handheld RF Power Meter

VXIbus Microwave Downconverter

NI PXI/PXIe-2543 Specifications

Keysight Technologies Oscilloscope Memory Architectures Why All Acquisition Memory is Not Created Equal. Application Note

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

R-1580A Microwave Downconverter. Product Brochure

Dual Scope Synchronization

Arbitrary Waveform Generators AWGSYNC01 Synchronization Hub Datasheet

Extension kit for R&S Vector Network Analysers

Video Reference Timing with Tektronix Signal Generators

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

SPC564A80CAL176 SPC564A70CAL176

Agilent U2000 Series USB Power Sensors

STEVAL-IKR001V7D. Sub Ghz transceiver daughterboard with power amplifier based on the SPIRIT1. Features. Description

AR SWORD Digital Receiver EXciter (DREX)

Agilent N5120A Baseband Studio for CPRI RE Test

ROBOT-M24LR16E-A. Evaluation board for the M24LR16E-R dual interface EEPROM. Features. Description

Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster. Application Note

Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope Wireless LAN Example Application

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

STEVAL-CCM003V1. Graphic panel with ZigBee features based on the STM32 and SPZBE260 module. Features. Description

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Keysight E6650A EXF Wireless Test Set for Femtocell. Data Sheet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent 83000A Series Microwave System Amplifiers

Electrical and Optical Clock Data Recovery Solutions up to 32 Gb/s

GM69010H DisplayPort, HDMI, and component input receiver Features Applications

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

Transcription:

Agilent M9362A-D01-F26 PXIe Quad Downconverter 10 MHz to 26.5 GHz Data Sheet Challenge the Boundaries of Test Agilent Modular Products

OVERVIEW Introduction The Agilent M9362A-D01-F26 is a PXIe 3-slot, 4-channel, coherent microwave downconverter with frequency coverage from 10 MHz to 26.5 GHz and 1.5 GHz of instantaneous bandwidth. The M9362A-D01-F26 is well suited for wideband signal capture where multiple channels are required for applications such as multi-channel coherent signal analysis, radar, SIGNIT, ELINT, MASINT, EW signal capture and analysis, and RF and microwave recording and analysis. Product description When combined with an Agilent M9302A Local Oscillator and one or more Agilent M9210A 4GS/s Digitizers, the M9362A- D01-F26 Downconverter can be used to synchronously capture up to 4 signals in up to 1.4 GHz bandwidth, with 10-bit resolution. Applications Features Frequency range: 10 MHz to 26.5 GHz 1.5 GHz bandwidth per channel Four-channel coherent downconversion Chassis slot compatibility: PXIe Hybrid, PXIe PXIe form factor Customer values Wide bandwidth, multi-channel downconversion in small form factor Synchronize multiple M9362A-D01-F26 downconverters for greater than 4 coherent channels Conforms to Modular Open Systems Approach (MOSA) Aerospace and defense Wireless communications Radar and wideband signal capture 2

EASY SETUP... TEST... AND MAINTENANCE Hardware platform Compliance The M9362A-D01-F26 is PXI compliant using either a PXIe or PXIe Hybrid slot. Designed to benefit from fast data interfaces, the product can be integrated with other test and automation modules in PXIe or PXIe Hybrid chassis slots. The PXI format offers high performance in a small, rugged package. It is an ideal deployment platform for many automated test systems. A wide array of complementary PXI products are currently available. Products include multimeters, waveform generators, local oscillators, digitizers, and switch multiplexers. Software platform IO libraries Agilent IO Libraries Suite offers FAST and EASY connection to instruments and the newest version extends that capability to include modular instruments. The Agilent IO Libraries Suite helps you display ALL of the modules in your system, whether they are PXI, PXIe, or PCIe. From here you can view information about the installed software or start the module s soft front panel. Launch the module s soft front panel directly from Agilent Connection Expert. Find the right driver from Agilent Connection Expert. Calibration intervals A functional certificate is supplied with the M9362A-D01-F26. No annual calibration is required. Figure 1. Agilent IO Libraries Suite 16.1 3

TECHNICAL SPECIFICATIONS All specifications are nominal unless otherwise noted. Input and output ports Frequency range and connectors Port Frequency range Connectors RF port 0.01 to 26.5 GHz 3.5 mm female LO port 0.01 to 26.5 GHz 3.5 mm female IF port 0.007 to 1.5 GHz SMA female Input and output power levels Input power damage levels RF port LO port Optimum power levels LO power RF power RF input @ 1 db compression Ports A through D IF output level 1 +18 dbm +5 dbm 0 dbm (± 1 db) -10 dbm > -10 dbm Conversion Gain (at -10 dbm input) Gain (db) 4 2 0-2 -4-6 -8-10 -12 Port A Port B Port C Port D -14 0 5 10 15 20 25 30 Frequency (GHz) Figure 2. Conversion Gain 1 IF output level is based on the RF input @ 1 db compression 4

Additional characteristics Noise figure Channel to channel isolation LO to IF leakage 24 db < -80 db < -20 db Port match RF port input match RF Input Port Match 0-5 -10-15 Input Match (db) -20-25 -30 Port A Port B Port C Port D -35-40 -45-50 0 5 10 15 20 25 30 Frequency (GHz) Figure 3. RF input port match 5

TECHNICAL SPECIFICATIONS All specifications are nominal unless otherwise noted. System requirements Operating systems Windows XP, Service Pack 3 or later (32-bit) 1 Windows 7 (32-bit and 64-bit) Starter, Home Basic, Home Premium, Professional, Ultimate, Enterprise Processor speed Available memory Available disk space 1 600 MHz or higher required 800 MHz recommended 256 MB minimum (1 GB or greater recommended) 1.5 GB available hard disk space, includes: 1 GB available for Microsoft.NET Framework 3.5 SP1 2 100 MB for Agilent IO Libraries Suite 1 GHz 32-bit (x86), 1 GHz 64-bit (x64), no support for Itanium 64 1 GB minimum 2 1.5 GB available hard disk space, includes: 1 GB available for Microsoft.NET Framework 3.5 SP1 2 100 MB for Agilent IO Libraries Suite Video Super VGA (800x600) 256 colors or more Support for DirectX 9 graphics with 128 MB graphics memory recommended (Super VGA graphics is supported) Browser Microsoft Internet Explorer 6.0 or greater Microsoft Internet Explorer 7 or greater 1. Because of the installation procedure, less memory may required for operation than is required for installation. 2..NET Framework Runtime Components are installed by default with Windows Vista and Windows 7. Therefore, you may not need this amount of available disk space Definitions for specifications Specifications describe the warranted performance of calibrated instruments that have been stored for a minimum of 2 hours within the operating temperature range of 0 to 55 C, unless otherwise stated, and after a 45 minute warm-up period. Data represented in this document are specifications unless otherwise noted. Characteristics describe product performance that is useful in the application of the product, but that is not covered by the product warranty. Characteristics are often referred to as Typical or Nominal values. Characteristic are represented in italics. Typical describes characteristic performance, which 80% of instruments are expected to meet when operated over a 20 to 30 C temperature range. Typical performance is not warranted. Nominal describes representative performance that is useful in the application of the product when operated over a 20 to 30 C temperature range. Nominal performance is not warranted. Note: All graphs contain measured data from several units at room temperature unless otherwise noted 6

RECOMMENDED CONFIGURATIONS Quad DC M9362A-D01-F26 Channels Digitizers M9210A 1, 3 Sample rate Analog bandwidth per channel 1 1 1 4 GS 1.4 GHz 1 1 2 1 2 GS 1.4 GHz 1 Local oscillator M9302A² Quad DC M9362A-D01-F26 Channels Digitizers M9210A 1, 3 Sample rate Analog bandwidth per channel 1 2 2 4 GS 1.4 GHz 1 1 4 2 2 GS 1.4 GHz 1 Local oscillator M9302A² 7

RECOMMENDED CONFIGURATIONS Quad DC M9362A-D01-F26 Channels Digitizers M9210A 1, 3 Sample rate Analog bandwidth per channel 1 3 3 4 GS 1.4 GHz 1 Local oscillator M9302A² Quad DC M9362A-D01-F26 Channels Digitizers M9210A 1, 3 Sample rate Analog bandwidth per channel 2 6 3 2 GS 1.4 GHz 1 Local oscillator M9302A² 1. The module displayed is the Agilent M9210A PXI-H High-speed Digitizing Scope: 10-bit, 2-4 GS/s 2. The module displayed is the Agilent M9302A PXI Local Oscillator, VCO-based, with frequency range from 2.75 GHz to 10 GHz, optimized for fast settling time to allow for fast frequency down conversion applications. 3. Maximum number of digitizers on AS Bus2 is three. 8

ORDERING Hardware Model M9362A-D01-F26 1 M9362AD01-CA1 M9362AD01-CA2 M9362AD01-CA3 M9362AD01-CA4 Recommended configuration Description PXIe Quad Downconverter: 10 MHz to 26.5 GHz IF Jumper Cables For Use With 4-M9202A Single CH Digitizers IF Jumper Cables For Use With 2-M9202A Dual CH Digitizers IF Jumper Cables For Use With The M9210A LO Interconnect Kit For Use With The M9302A Includes software and product information on CD RF IN A RF IN B RF IN C RF IN D IF OUT A IF OUT B IF OUT C IF OUT D LO OUT 1 For the M9362A-D01-F26 to work properly, at least one PXIe chassis and one PXIe controller type must be available. Related products LO IN Figure 4. M9362A-DO1-F26 PXIe Quad Downconverter block diagram Model M9210A M9302A M9018A M9036A Description PXI-H High-speed Digitizing Scope: 10-bit PXI Local Oscillator: 3 GHz to 10 GHz 18-slot PXIe chassis PXIe Embedded Controller Software Model Supported application development environments (ADE) Description Agilent IO Libraries: Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB WARRANTY AND CALIBRATION Figure 5. Example of a 2-channel, 400 MHz analysis Advantage Services: Calibration and warranty Agilent Advantage Services is committed to your success throughout your equipment s lifetime. Warranty Standard warranty on the M9362A-D01 is 1 year. 9

The modular tangram The four-sided geometric symbol that appears in this document is called a tangram. The goal of this seven-piece puzzle is to create identifiable shapes from simple to complex. As with a tangram, the possibilities may seem infinite as you begin to create a new test system. With a set of clearly defined elements hardware, software Agilent can help you create the system you need, from simple to complex. Challenge the Boundaries of Test Agilent Modular Products myagilent myagilent www.agilent.com/find/myagilent www.pxisa.org Agilent SolutionPartners www.agilent.com/find/solutionpartners www.agilent.com www.agilent.com/find/modular www.agilent.com/find/m9362a-d01 For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Brazil Mexico United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries Europe & Middle East Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom (877) 894 4414 (11) 4197 3600 01800 5064 800 (800) 829 4444 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100 32 (0) 2 404 93 40 45 45 80 12 15 358 (0) 10 855 2100 0825 010 700* *0.125 /minute 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus (BP-11-07-13) Product specifications and descriptions in this document subject to change without notice. PICMG and the PICMG logo, CompactPCI and the CompactPCI logo, AdvancedTCA and the AdvancedTCA logo are US registered trademarks of the PCI Industrial Computers Manufacturers Group. PCIe and PCI EXPRESS are registered trademarks and/or service marks of PCI-SIG. Agilent Technologies, Inc. 2013 Published in USA, November 20, 2013 5990-6624EN