LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Similar documents
LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2ME. Main. Device short name. Device application

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV2ME. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

A V 50Hz / V 60Hz

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

AS09..S 3-pole Contactors - Spring Terminals

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Series CT7N Bimetallic Overload Relays

Magnecraft Power Relays

Datasheet - SRB301LC 24VAC/DC

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Type: DILM25 10(24V50HZ) Article No.:

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Type: DILM12 10(24VDC) Article No.:

Ordering details. Approval. Classification

Minicontactorrelay,2NO/2NC,DCoperated

Safety dialogue solutions

Datasheet - SRB-E-201ST

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

02/11/2015

16 A and 25 A power contactors with or without handle

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

AC1036. Definite Purpose Contactors

Bulletin 190 IEC Modular Starter System

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Modular pulse operated latching relay 16 A

Circuit-Breakers for Motor Protection Series 8523/8

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

TeSys circuit-breakers

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Data Sheet Definite Purpose Contactors Ex9CK Series

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Manual Motor Starter Specifcations

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Kuhnke Technical Data. Contact Details

High performance circuit breakers

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Series CDP2 Definite Purpose Contactors

Interface Relays and Optocouplers Product group picture

Series CDP2 Definite Purpose Contactors

ALLEN BRADLEY TIMING RELAY

llen-bradley 194R-HM4-NFPA3

Magnetic and Hydraulic-Magnetic Circuit Breaker

Pluggable interface relays CR-M Miniature relays

DMX and 4000 air circuit breakers from 800 to 4000 A

Panel-mounting thermostats, type series EM

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Variable speed drives Altivar Process Three-phase supply voltage: V 50/60 Hz Wall-mounting drives

Power Circuit of a UL508A Panel. Typical UL489 Application

LED control gear Compact fixed output

Bulletin 100-G IEC Contactors

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Generator protection relay

Definite Purpose Contactors

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Transcription:

Characteristics TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 230 V AC 50/60 Hz coil Product availability : Stock - Normally stocked in distribution facility Price* : 172.00 USD Main Range of product Range Product name Product or component type Device short name Contactor application Utilisation category Poles description Pole contact composition System Voltage [Ie] rated operational current Motor power kw Motor power hp Control circuit type [Uc] control circuit voltage Auxiliary contact composition Jul 27, 2017 TeSys D TeSys TeSys D Contactor LC1D Motor control Resistive load AC-1 AC-4 AC-3 3P 3 NO <= 300 V DC power circuit <= 690 V AC 25...400 Hz power circuit 32 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit 50 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit 15 kw at 380...400 V AC 50/60 Hz AC-3 7.5 kw at 220...230 V AC 50/60 Hz AC-3 18.5 kw at 500 V AC 50/60 Hz AC-3 18.5 kw at 660...690 V AC 50/60 Hz AC-3 15 kw at 415...440 V AC 50/60 Hz AC-3 7.5 kw at 400 V AC 50/60 Hz AC-4 2 hp at 115 V AC 50/60 Hz 1 phase motors 5 hp at 230/240 V AC 50/60 Hz 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz 3 phases motors 10 hp at 230/240 V AC 50/60 Hz 3 phases motors 20 hp at 460/480 V AC 50/60 Hz 3 phases motors 30 hp at 575/600 V AC 50/60 Hz 3 phases motors AC 50/60 Hz 230 V AC 50/60 Hz 1 NO + 1 NC 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

[Uimp] rated impulse withstand voltage Conforming to IEC 60947 Overvoltage category [Ith] conventional free air thermal current III 50 A at <= 140 F (60 C) power circuit 10 A at <= 140 F (60 C) signalling circuit Irms rated making capacity 550 A at 440 V power circuit conforming to IEC 60947 140 A AC signalling circuit conforming to IEC 60947-5-1 250 A DC signalling circuit conforming to IEC 60947-5-1 Rated breaking capacity 550 A at 440 V power circuit conforming to IEC 60947 [Icw] rated short-time withstand current Associated fuse rating Average impedance [Ui] rated insulation voltage Electrical durability Power dissipation per pole Protective cover Mounting support 138 A <= 104 F (40 C) 1 min power circuit 260 A <= 104 F (40 C) 10 s power circuit 430 A <= 104 F (40 C) 1 s power circuit 60 A <= 104 F (40 C) 10 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 63 A gg at <= 690 V coordination type 1 power circuit 63 A gg at <= 690 V coordination type 2 power circuit 10 A gg signalling circuit conforming to IEC 60947-5-1 2 mohm at 50 Hz - Ith 50 A power circuit 600 V power circuit certifications CSA 600 V power circuit certifications UL 690 V power circuit conforming to IEC 60947-4-1 690 V signalling circuit conforming to IEC 60947-1 600 V signalling circuit certifications CSA 600 V signalling circuit certifications UL 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 2 W AC-3 5 W AC-1 With Plate Rail Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 Product certifications Connections - terminals CCC GL BV UL LROS (Lloyds register of shipping) RINA CSA DNV GOST Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (1.5...10 mm²) - cable stiffness: solid - Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - Power circuit: screw clamp terminals 2 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - Power circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (1...10 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible - with cable end 2

Tightening torque Operating time Power circuit: screw clamp terminals 2 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: solid - Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 22.12 lbf.in (2.5 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 22.12 lbf.in (2.5 N.m) - on screw clamp terminals - with screwdriver Philips No 2 4...19 ms opening 12...22 ms closing Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability Operating rate 15 Mcycles 3600 cyc/h at <= 140 F (60 C) Complementary Coil technology Control circuit voltage limits Inrush power in VA Hold-in power consumption in VA Heat dissipation Without built-in suppressor module 0.3...0.6 Uc drop-out at 140 F (60 C), AC 50/60 Hz 0.8...1.1 Uc operational at 140 F (60 C), AC 50 Hz 0.85...1.1 Uc operational at 140 F (60 C), AC 60 Hz 70 VA at 68 F (20 C) (cos ϕ 0.75) 60 Hz 70 VA at 68 F (20 C) (cos ϕ 0.75) 50 Hz 7.5 VA at 68 F (20 C) (cos ϕ 0.3) 60 Hz 7 VA at 68 F (20 C) (cos ϕ 0.3) 50 Hz 2...3 W at 50/60 Hz Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance Power range Motor starter type Contactor coil voltage 25...400 Hz 5 ma signalling circuit 17 V signalling circuit 1.5 ms on de-energisation (between NC and NO contact) 1.5 ms on energisation (between NC and NO contact) > 10 MOhm signalling circuit 7...11 kw 200...240 V 3 phases 15...25 kw 380...440 V 3 phases 15...25 kw 480...500 V 3 phases Direct on-line contactor 230 V AC standard Environment IP degree of protection IP2x front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation Ambient air temperature for storage Permissible ambient air temperature around the device Operating altitude -4...140 F (-20...60 C) -76...176 F (-60...80 C) -40...158 F (-40...70 C) at Uc 9842.52 ft (3000 m) without derating in temperature Fire resistance 1562 F (850 C) conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor closed 15 Gn for 11 ms Shocks contactor open 8 Gn for 11 ms 3.35 in (85 mm) 1.77 in (45 mm) 3.62 in (92 mm) 0.83 lb(us) (0.375 kg) 3

Ordering and shipping details Category 22345 - CTR,D-LINE,OPEN,NONREV-NEW Discount Schedule I12 GTIN 00785901296614 Nbr. of units in pkg. 1 Package weight(lbs) 0.95999999999999996 Returnability Y Country of origin ID Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 0627 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Available Contractual warranty Warranty period 18 months 4

Dimensions Drawings Dimensions (1) Including LAD 4BB (2) Minimum electrical clearance LC1 D25 D38 (3-pole) b without add-on blocks 85 b1 with LAD 4BB 98 with LA4 D 2 114 (1) with LA4 DF, DT 123 (1) with LA4 DW, DL 130 (1) c without cover or add-on blocks 90 with cover, without 92add-on blocks c1 with LAD N or C (2 or 4 contacts) 123 c2 with LA6 DK10, LAD 6K10 135 c3 with LAD T, R, S 143 with LAD T, R, S and 147 sealing cover (1) Including LAD 4BB. 5

Connections and Schema Wiring 6

Motor Starter BOM Our Proposal - Type 1 : Circuit Breaker + Contactor for Motor Power 15 kw and 415 VAC Motor Power (kw) Icu (ka) Breaker Contactor 15 10 GV2ME32 Non contractual pictures. Type 1 coordination requires that in a short-circuit condition, the contactor or starter must not present any danger to personnel or installations and must not be able to resume operation without repair or the replacement of parts. 7