NEW CYCLOTRON DEVELOPMENTS AT IBA

Similar documents
Recent developments in cyclotrons for proton therapy at IBA

III. Proton-therapytherapy. Rome SB - 3/5 1

THE IBA SUPERCONDUCTING SYNCHROCYCLOTRON PROJECT S2C2

Cyclotron Institute upgrade project. H. L. Clark, F. Abegglen, G. Chubarian, G. Derrig, G. Kim, D. May, and G. Tabacaru

Particle Beam Production - A Synchrotron-Based System - Prof. Dr. Thomas Haberer Scientific-technical Director Heidelberg Iontherapy Center

Cyclotron Institute upgrade project. H. L. Clark, F. Abegglen, G. Chubarian, G. Derrig, G. Kim, D. May, B. Roeder and G. Tabacaru

45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests*

Hadron Therapy Technologies

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

4.4 Injector Linear Accelerator

PRESENT STATUS OF J-PARC

OPERATIONAL EXPERIENCE AT J-PARC

EPJ Web of Conferences 95,

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

A NOVEL GANTRY FOR PROTON THERAPY AT THE PAUL SCHERRER INSTITUTE

LHC Beam Instrumentation Further Discussion

COMMISSIONING SCENARIOS FOR THE J-PARC ACCELERATOR COMPLEX

PEP II Design Outline

THE NEW AXIAL BUNCHER AT INFN-LNS

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Particle Therapy with the Varian / ACCEL 250 MeV S.C. Proton Cyclotron

The PEFP 20-MeV Proton Linear Accelerator

100 MeV H - CYCLOTRON DEVELOPMENT AND 800 MeV PROTON CYCLOTRON PROPOSAL*

PEP-I1 RF Feedback System Simulation

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

DIRECT DRIVE ROTARY TABLES SRT SERIES

BEAM DIAGNOSTICS IN THE CNAO INJECTION LINES COMMISSIONING

The ESS Accelerator. For Norwegian Industry and Research. Oslo, 24 Sept Håkan Danared Deputy Head Accelerator Division Group Leader Beam Physics

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Development of New Carbon Therapy Facility and Future Plan of HIMAC

Upgrading LHC Luminosity

1.0 Abstract : 2.0 The drift tube Linac for LEHIPA

HIGH-INTENSITY PROTON BEAMS AT CERN AND THE SPL STUDY

CERN S PROTON SYNCHROTRON COMPLEX OPERATION TEAMS AND DIAGNOSTICS APPLICATIONS

Beam instrumentation at the 1-MW proton J-PARC RCS

Low Frequency Gyrotrons for Fusion

ESS: The Machine. Bucharest, 24 April Håkan Danared Deputy Head Accelerator Division. H. Danared Industry & Partner Days Bucharest Page 1

Design of the linear accelerator for the MYRRHA project

Detailed Design Report

New Filling Pattern for SLS-FEMTO

Basic rules for the design of RF Controls in High Intensity Proton Linacs. Particularities of proton linacs wrt electron linacs

Status of CTF3. G.Geschonke CERN, AB

Improvements to Siemens Eclipse PET Cyclotron Penning Ion Source

Design Studies For The LCLS 120 Hz RF Gun Injector

Recent ITER-Relevant Gyrotron Tests

Implementing a Proton Beam Scanning System within an Operating Clinical Facility

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

G. Pittá(*), S. Braccini TERA Foundation, Novara, Italy (*) Corresponding author.

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

30 GHz Power Production / Beam Line

Status of BESSY II and berlinpro. Wolfgang Anders. Helmholtz-Zentrum Berlin for Materials and Energy (HZB) 20th ESLS-RF Meeting

Proton Engineering Frontier Project

DC ELV Accelerators: Development and Application

CPI Gyrotrons For Fusion EC Heating

FIRST SIMULTANEOUS TOP-UP OPERATION OF THREE DIFFERENT RINGS IN KEK INJECTOR LINAC

The Construction Status of CSNS Linac

BEAM DYNAMICS AND EXPERIMENT OF CPHS LINAC *

Studies on an S-band bunching system with hybrid buncher

Activities from Cyclotron facility at German Cancer Research Center (DKFZ), Heidelberg

Present Status and Future Upgrade of KEKB Injector Linac

arxiv:hep-ex/ v1 27 Nov 2003

Promises and Perils of Proton Therapy Beam Delivery (Implications) or Towards Cost Effective Particle Therapy

2008 JINST 3 S LHC Machine THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS. Lyndon Evans 1 and Philip Bryant (editors) 2

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

TRIUMF CYCLOTRON MAIN MAGNET POWER SUPPLY REPLACEMENT

RF Power Generation II

SPEAR 3: Operations Update and Impact of Top-Off Injection

DESIGN OF 1.2-GEV SCL AS NEW INJECTOR FOR THE BNL AGS*

KEKB Accelerator Physics Report

THE OPERATION EXPERIENCE AT KOMAC*

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

* National Laboratory for High Energy Physics (KEK) **** Institute for Nuclear Study, University of Tokyo (INS)

The field cage for a large TPC prototype

NEW METHOD FOR KLYSTRON MODELING

North Damping Ring RF

The Elettra Storage Ring and Top-Up Operation

A HIGH-POWER SUPERCONDUCTING H - LINAC (SPL) AT CERN

RF Design of the LCLS Gun C.Limborg, Z.Li, L.Xiao, J.F. Schmerge, D.Dowell, S.Gierman, E.Bong, S.Gilevich February 9, 2005

RF plans for ESS. Morten Jensen. ESLS-RF 2013 Berlin

Digital BPMs and Orbit Feedback Systems

LCLS Injector Technical Review

LIGHT PROTON THERAPY PROJECT

HIGH POWER BEAM DUMP AND TARGET / ACCELERATOR INTERFACE PROCEDURES *

Program to improve the ion beam formation and transmission at JYFL

The European Spallation Source

Joint Institute for Nuclear Research Flerov Laboratory of Nuclear Reactions

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

UPGRADE OF THE PSI CYCLOTRON FACILITY TO 1.8 MW

CEPC Klystron Development

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

DIAGNOSTIC INSTRUMENTATION FOR MEDICAL ACCELERATOR FACILITIES

ABORT DIAGNOSTICS AND ANALYSIS DURING KEKB OPERATION

vacuum analysis surface science plasma diagnostics gas analysis

Synergies: Therapy & Thorium, FFAG & RCS

Transcription:

NEW CYCLOTRON DEVELOPMENTS AT Y. Jongen, W. Kleeven and S.Zaremba, Chemin du Cyclotron 3, B-1348 Louvain-la-Neuve, Belgium Abstract This paper describes some recent cyclotron developments done at - Ion Beam Applications s.a. For radioisotope production, the self-extracting cyclotron now works very reliably at extracted beam currents above 1 ma, producing Pd103 for Brachytherapy devices. Based on a better understanding of the self-extraction process gained with this first machine, an improved design has been made, reducing the extraction losses to less than 10% and allowing extracted currents in excess of 2.5 ma. In the field of protontherapy, progress has been made in the fast and accurate control of the extracted beam current, allowing to slave the extracted beam to an external control signal up to 2.5 khz, and this over a large dynamic range which is essential for high performance proton therapy using pencil beam scanning techniques. For the radiotherapy of cancer using Carbon beams, has made the design of a fixed field, fixed frequency, elliptical gap, K = 1200 superconducting cyclotron, allowing to accelerate ions with Q/M = 0.5 to 300 MeV/U. new development efforts have been on the target design. The target material consists of a thin Rhodium wire that is wound around an aluminum drum which is rotating around its axis and which is placed at angle of about 15 degrees with respect to the beam direction. Cooling of the Rhodium wire has been substantially improved by applying a convective flow of helium on the rotating drum. Figure 2 shows the target station that is placed in a separate vault at about 8 meters from the cyclotron. THE SELF-EXTRACTING CYCLOTRON Current Status of the Prototype The self-extracting cyclotron [1] is a high-intensity 14 MeV H + machine for isotope production. Figure 1 shows of photograph of the interior of this machine. There is no electrostatic deflector. Extraction is achieved with a special shaping of the magnetic field. There are two long poles and two short poles, both with an elliptical gap profile; this provides a steep fall off of the magnetic field at the pole radii. An extraction groove is machined in the iron of one of the longer poles. First harmonic coils create an orbit separation at the entrance of the extraction path and extract the beam. A high power low activation beam catcher is used to collect beam that is not properly extracted. The prototype machine is in use for production of Pd-103. Commercial use of the machine started in 2002 and since then the beam current on target could be gradually increased and now routine productions of up to 3 weeks of duration with 1 ma of beam current on target are normal. Beams of more than 1.5 ma have been extracted and transported. The extraction efficiency is 80% for low beam intensity and decreases to about 75% for production intensity (1 ma). This slight decrease is probably due to an increase of dee-voltage ripple induced by variations of the cavity beam loading resulting from ion source plasma noise. The machine is very easy to operate and also extremely stable and reliable. The main Figure 1: Median plane view and extraction path in the prototype self-extracting cyclotron, showing the groove in the pole, the gradient corrector and the beam separator. The harmonic coils are placed underneath the pole covers Figure 2: The Pd-103 target station is irradiated by the self-extracted beam of the SEC prototype

Development of an Improved Magnetic Design Although the prototype SEC is operating reliably in an industrial environment, the extraction efficiency of 75% and the corresponding beam loss on the beam separator limits the maximum beam current. It was only after building and operating the prototype that we came to understand better the physics and full optimisation scheme of self-extraction. Therefore, the following improved concepts have been developed: Instead of milling a groove parallel to the beam trajectory into a circular pole, we decided to make the pole edge parallel to the beam trajectory. The pole surface is therefore machined on a NC milling machine instead of on a NC lathe. By this, a sharper field transition from the isochronous region to the extraction path is achieved. Since the groove is inducing a strong sextupole in the extracted beam optics, it has been changed by a kind of plateau. As can be seen from Figure 3, this results in a sharp drop of the field in the extraction path with about 3 kg, but there is no subsequent field rise (sextupole) as is found in the prototype. The vertical pole gap near extraction has been optimised such that the radial tune function ν R shows a slow transition from 1.1 down to about 0.6 in the last ten turns before extraction. This is illustrated in Figure 4. The low value of ν R results in a large turn separation via the mechanism of precessional extraction. This behaviour of ν R obtained with a field bump between 450 mm and 520 mm as illustrated in Figure 3. Of course such a shaping of the radial tune influences the isochronism of the field but the induced RF phase motion is still limited and fully acceptable as is shown in Figure 5. Figure 3: Magnetic field on the middle of the extractionsector. The field bump in between 450 mm and 520 mm creates the required fall of the ν R function near extraction. The extraction path in between 520 mm and 560 mm is created by machining of the plateau in the pole. The dotted line gives the filed on the other three sectors, which have an extended radius Extensive use of the OPERA3D finite element code of Vector Fields was made in order to include those features and optimise the magnet. Figure 6 shows the modelling of the extraction sector. As can be seen, iron is removed from underneath the pole tip, in order to be able to properly adjust the magnetic flux flow towards the extraction path. At the same time extensive orbit tracking simulations were performed in order to find the extraction efficiency and the extracted beam quality. The Advanced Orbit Code (AOC) was used to simulate fully accelerated beams (each containing multiple-thousands of particles) from the ion source up to the exit of the cyclotron. These simulations took into account precise OPERA3D electrical field maps from the central region but also from the full dee-structure as well as the precise isochronised OPERA3D magnetic field maps. During these calculations the three freely available magnetic field parameters (two harmonic coil settings and the main coil) Figure 4: Shaping of the radial tune function near extraction as needed for increasing the turn separation were optimised in order to find the maximum extraction efficiency. These computations were done on a cluster of 11 personal computers in order to gain calculation speed. With these simulations an extraction efficiency of at least 90% is predicted for the improved design and an extracted beam emittance of about 100 π mm-mrad. These values must be compared to 75% and 300 π mm-mrad

respectively for the prototype. We have good confidence in these figures, because the same simulations were carried out for the prototype and here, good agreement with the experimental values were found. Figure 5: RF phase slip for the new SEC magnetic design. The phase motion near extraction relates to the corresponding shape of radial tune as shown in Figure 2 Figure 6: The OPERA3D software was used extensively for modelling the SEC II. Iron is removed underneath the pole tip on the extraction sector in order to adjust the magnetic flux towards the extraction path PROTON THERAPY SYSTEMS Overview During the last 10 years, took a leadership position on the proton therapy market (see Table 1). NPTC - Northeast Proton Therapy Center at MGH in Boston MA, USA was the first proton therapy project. The C230 cyclotron was developed with the Japanese company SHI - Sumitomo Heavy Industries. Treatment of patient started on November 8 th, 2001. The cumulative up-time of 95 percent confirms the reliability of equipment. The collaboration between and SHI was very successful. The second SHI and proton therapy system was constructed by SHI in NCC National Cancer Center in Kashiwa. The first treatment of patients has been done even before NPTC. Today (October 2004), field engineers perform initial beam tests and validation of other equipment in Wanjie Tumor Hospital in Zibo, China. We expect that the first treatment of a patient in the fixed beam room will take place before the end of this year. At the same time at, we test C230 cyclotron destined for Florida Proton Therapy Institute at University of Florida in Jacksonville FL, USA. Table 1: Sales of proton therapy systems Year Customer Provider 1995 MGH, Boston MA, USA 1996 NCC, Kashiwa, Japan SHI/ 1996-99 Tsukuba University Hitachi Wakasa Wan Energy Research Center Shizuoka Prefecture Hitachi Mitsubi shi 2001 PSI Villigen, Switzerland Accel Wanjie Tumor Hospital Zibo, China Chang An PMC Beijing, China 2002 Rinecker PTC Munchen, Germany Korean NCC - Seoul IUCF (MPRI), Bloomington IN, USA M.D. Anderson CC, Houston TX, USA 2004 University of Florida, Jacksonville FL, USA Accel Hitachi

Fast beam current adjustment The high dynamic beam adjustment is necessary for Pencil Beam Scanning (PBS) and to compensate the spread of Bragg peak tilt due to imperfect machining of range modulator wheel. The current adjustment is done by an electronic unit that controls the ion source arc power supply. Input signals are coming from treatment rooms and from an ionization chamber located at the cyclotron exit which measures the beam current. The feedback system in this case is complex due to delay caused by the beam acceleration. The arc current to beam current ratio is non-linear and also may drift over long time periods. The beam is noisy at higher frequencies. Disturbances as deflector or RF system discharge can cause the beam to disappear for some short instant. In such moment, the adjustment system should not increase the arc current. To improve the adjustment we added feed-front predictive system. Before each irradiation the proton therapy system performs 10 sweeps and records values of the arc current and the extracted beam current. In this way we obtain the look-up table that can be used later. The error signal between extracted current and the given function uses the look-up table to adjust settings of the ion source arc power supply. CARBON-PROTON, 300 MEV/U, Q/M=1/2 SUPER-CONDUCTING CYCLOTRON FOR HADRON THERAPY This cyclotron is based on the design of the current PT (proton therapy) C230 cyclotron. It can accelerate ions with Q/M = ½, such as 12 C 6+, 10 B 5+, 6 Li 3+, 4 He 2+ and H 2 + at an energy of 300 MeV/u. The acceleration of Q/M = 1/2 ions at 300 MeV/u requires a larger extraction radius of 1.48 m and a larger average magnetic field of 3.7 Tesla at extraction. At extraction radius, the hill field is 4.5 T and the valley field is 2.45 T. The spiral angle increases from zero in the center to 66 at extraction radius. The RF frequency is 86 MHz, on the fourth harmonic mode. The RF cavity is almost exactly a scaled up version of the cavity of the 235 MeV proton cyclotron. The azimuthal length of dee is 35 degrees and nominal dee voltage is 200 kv. Dee voltage varies with radius to maximize kinetic energy gain per turn in the extraction region. The outside diameter is only 5.88 meter, in contrast with 4.7 m for the current 230 MeV proton cyclotron. The magnet height is 3.2 m and the mass of the steel is about 656 Tons. An artist view of the cyclotron is presented on Figure 7. The super-conducting coils have a relatively modest current density. The super-conducting wire, based on Nb- Ti filaments has a large copper to superconductor ratio, resulting in a cryo-stable design. The coil operates at 4.2 K in a helium bath. Like in the latest super-conducting cyclotrons, the helium evaporated in the super-conducting coils in re-liquefied by a set of five cryo-generators located in a re-liquefaction reservoir adjacent to the coils Two or three external ions sources are mounted on a switching magnet on top of the cyclotron. The C 6+ are produced by a high performance ECR source provided by Pantechnik (Caen, France). The alphas are also produced by a small ECR source, while the H 2 + are produced by a multicusp ion source. In order to allow a quick change between ion species, all three ion sources are kept in operation. The selection of the beam is made by the switching magnet also placed on top of the axial injection line. All species have a Q/M ratio of 1/2 and all ion sources are at the same potential, so that only a small retuning of the frequency is needed to switch from H 2 + to alphas or to C 6+. We expect that the time to switch species can be not more than two minutes, the same as the time needed to retune the beam transport line between different treatment rooms. The beam is injected in the cyclotron by a quite classical axial injection line with a pseudocylindrical spiral inflector. The extraction uses an electrostatic deflector and gradient corrector quite similar to the deflector used in the PT cyclotron. In addition, extraction by stripping of the H 2 + could be considered to get protons of kinetic energy lower than 300 MeV/u. Figure 7. Artist view of the median plane in Carbonproton, 300 MeV/u, super-conducting cyclotron. 110 MEV, H - AND H + HIGH CURRENT CYCLOTRON FOR TRADE This cyclotron was design for the ENEA in Italy (prof. Carlo Rubbia). The proton beam of this cyclotron was foreseen to drive-in sub critical mode a low power (2 MW thermal power) TRIGA reactor of the ENEA located in

Casaccia (Italy). TRADE stands for TRiga Accelerator Driven Experiment. The TRADE experiment is funded by the EC, but the needed cyclotron will be purchased by the ENEA. For this cyclotron, the requirements were: a beam of extracted protons (H + ) having kinetic energy of 110 MeV, the beam current of 2 ma. A beam will be extracted also as H - to be injected by stripping in a booster synchrotron. the bias of the source is increased to 60 kv. To avoid problems of arcing in the inflector, the concept of a magnetostatic inflector with symmetry of revolution was developed. The Figure 8 presents this concept. In the self-extraction mode, the beam separator was replaced by stripper foil, in such a way that the beam not properly extracted by self-extraction was extracted by stripping. In this way a true 100% extraction efficiency is always achieved. CONCLUSIONS Since 1986, is a key player in the development of not only cyclotrons but also several other types of industrial accelerators. The self-extracting cyclotron now has become a reality as an industrial high current machine for isotope production. During the last 15 years has accumulated a large amount of experience in the field of proton therapy and was able to obtain the CE-clearance (Europe) and FDA-approval (USA) for its equipment With the proposed new concepts for hadron therapy and the Trade-experiment, wants to continue its efforts towards future developments in the field of cyclotrons Figure 8. View of a magnetostatic inflector with symmetry of revolution in the end of axial injection line. proposed an H - negative ion cyclotron, where the beam could be extracted either by self-extraction or by stripping. The original aspect of this design is that the sectors are not circular, but the outside border of the sectors follows the trajectory of the beam. To reach 2 ma, and to overcome space charge limits in the axial injection, REFERENCES [1] W. Kleeven, S. Lucas et.al., The self-extracting cyclotron project, Proceedings of the XXXIII European Cyclotron Progress Meeting, ECPM2002, NUKLEONIKA 48, supplement 2 (2003)59-67.