Installation Guide. CTI/8 RS422/BBVCoax Telemetry Interface 8 channel. Building Block Video Ltd., 17 Apex Park,

Similar documents
Installation Guide. CTI/16 RS422/BBV Coax Telemetry Interface 16 channel. Building Block Video Ltd., Diplocks 17 Apex Park Industrial Estate,

Installation Guide. CTI/16 RS422/BBV Coax Telemetry Interface 16 channel. Building Block Video Ltd., Diplocks 17 Apex Park Industrial Estate,

Installation Guide. CTI/1 RS422/BBV Coax Telemetry Interface Single Channel

BBV REAL TIME HQ DISPLAY QUAD MANUAL

Installation Guide RX10X. Multi Protocol Dome Interface Receiver

Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide

Rx400DC TELEMETRY RECEIVER INSTALLATION GUIDE

SCT CAMERA CONTROL CODE TRANSLATOR AD MANCHESTER to PELCO RS-422 Ver. 1.51

KBC1 / KBC2. Installation and Operation Guide

SY-HDBT-100 Extender Set

Model: AV D Keyboard Controller. User Manual. Please Read this User Manual throughout before using.

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

ARS x4 MATRIX SWITCHER Instruction Manual

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

SY-HDBT-SLIM-100S Extender Set

Active UTP Transceiver Hub Installation Guide

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

AU-A300 Integrated 2 Channel Zone Amplifier OPERATION MANUAL

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

User Manual POE. Twisted Pair POE Extender

DIGI-BSR-4K Installation Guide

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

PRO-SDI44/84/124/164. 4x4/8x4/12x4/16x4 3G-SDI Matrix Switchers OPERATION MANUAL

Model 1421 Distribution Amplifier

ZIG-POC-100. HDBaseT HDMI Extender

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

High Definition Digital Video Tracking Matrix Switcher

Quick Operation Guide of LTN7700/7600 Series NVR

EL-5500 Advanced HDMI/VGA Presentation Switch OPERATION MANUAL

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

ZIG-POEPRO-70A. HDBaseT HDMI Extender

SIMATRIX NEO V2 Modular Video Matrix

Active UTP Transceiver Hub

User Manual TP422P-4K. Ultra-thin HDBaseT Extender. All Rights Reserved. Version: TP422P-4K_2016V1.1

CMSDI G-SDI Matrix

EGE-IR Bi-directional Infrared Matrix

MS2540 Current Loop Receiver with RS485 Communication

CMLUX-4H4CAT. 4 by 4 HDMI V1.3 over CAT 6 Matrix with IR Return Control. Operation Manual CMLUX-4H4CAT

switching, distribution, interfacing and control products for computer graphic, multi-media and audio visual systems integration

VGA & RS-232 & Audio CAT5 Extender with RGB Delay Control Quick Installation Guide

4 Channel Video and IP Over Fiber Extender Kit with RS485 Data. User Manual L-4VID-1IP-FE-TX-RX

CP-255ID CV, SV, VGA and DVI to DVI Scaler / Converter OPERATION MANUAL

Operating Manual. CAT5 Audio Balun KD-CAT5XST

PU-4H4HBT 4 x 4 HDMI HDBaseT Matrix (inc. PoE) OPERATIONS MANUAL

Model#: IN-MDRI3MF. Hardware User Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04

HDBaseT Extender Set 100m User Guide

OWNER S MANUAL. HDBaseT EXTENDER B-500-EXT-330-RS-IP

E3/DS3 Fibre Extender

Multi-Channel Passive Transceiver Hubs Installation Sheet

Operating Instructions

Model#: IN-DI2MIRF 2MP Indoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

PoE Over Coax Extender Kit

Quick Installation Guide

.Power Distribution Center. PD-1. Instruction Manual

Salient Systems June, N Mopac Expy, Bldg 3, Ste 700 Austin, Texas FAX

CH-1605RXV 4K UHD+ HDMI over HDBaseT 2.0 Receiver (PD) with HDR/ARC

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

Monochrome Video Monitors

SD/HD/3G-SDI Video + Power + Data RS-485 Transmission over Coax Kit

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

VG A 88 VGA88. 8x8 VGA Matrix Switcher. VGA88 manual.indd 1 12/3/07 2:24:47 PM

TBC & Matrix Switcher TBC-5000 Instruction Manual

NS-3 RF Noise Source Operation Manual

Model: UHD41-ARC. Installation Guide

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

-TECH DIGITAL. Explore The High DefinitionWorld. Website: Hot Line: [US] USER MANUAL

Marshall Electronics. Broadcast A/V Division VAC-HT12-KIT. 4K HDBaseT Extender Kit. User Manual

PU-304-KIT Digital Audio over CAT6 Extender TXRX Set OPERATIONS MANUAL

User Manual TPU421. Ultra-thin HDBaseT Extender. All Rights Reserved. Version: TPU421_2016V1.0

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ITC-200B Quick Start Guide

Zigen ZIG-PAX. Premium Digital / Analog Audio Extender. 4K 60 Hz 4:4:4 HDCP 2.2 ZigNet, Full Web Interface and System Diagnostics

Installation Note. Agilent 89441A Option AYC Installation Kit

Stratos Duo RGB. User Manual. Order code: EQLED371

User Manual. HDBT-EC Set. 4K HDBaseT Extender HDMI HDBaseT Extender Pair with PoC & Bi-Directional IR Support 4K UHD

DXI SAC Software: Configuring a CCTV Switcher. Table of Contents

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

CP-255ID Multi-Format to DVI Scaler

Salient Systems July, N. MoPac Expy. Building 3, Suite 700 Austin, TX FAX

CH-1602TX & CH-1602RX HDMI/Audio over CAT5e/6/7 Extender with 48V PoE

3GSDI Audio Embedder

RS-232 to Multi-Mode Fiber Optic Media Converter

CONTRACTORS SPECIFICATION

ORDER CODE: EQLED65 USER MANUAL

ANI-PiP-LITE. HDMI 2x1 Multi-Viewer with PIP INSTRUCTION MANUAL. A-NeuVideo.com Frisco, Texas (469) AUDIO / VIDEO MANUFACTURER

HDBaseT EXTENDER B-600-EXT-330-RS-IP INSTALLATION MANUAL

ACTIVE IF SPLITTER/COMBINER UHP-IFS

VGA, Audio & RS-232 Serial with IR Pass-Thru over Single CAT5 /RJ45 Extender Kit

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

CH-2538TXWPKD 4K UHD HDMI/VGA over HDBaseT Wallplate Transmitter. CH-2527RX 4K UHD HDMI over HDBaseT Receiver. Operation Manual

AMU2-2MHD+ Audio monitoring Unit

music hall pa2.2 INSTRUCTION MANUAL music hall

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SW2 SWITCH 3: CONTROL SYSTEM COMPATIBILITY

192 Channel DMX Controller

Transcription:

CTI/8 RS422/BBVCoax Telemetry Interface 8 channel Installation Guide Building Block Video Ltd., 17 Apex Park, Diplocks Building Industrial Block Video Estate, Ltd Hailsham, 17 Apex Park East Sussex, BN27 3JU UK. Tel: Diplocks +44(0)1323 Industrial 842727 Estate Fax: Hailsham, +44(0)1323 East Sussex, 842728 BN27 3JU, UK Support: Tel: + 44 +44(0)1323 842727 444600 www.bbvcctv.com Fax: + 44 (0) 1323 842728 Support: + 44 (0) 1323 444600 www.bbvcctv.com

Contents Pre-installation checks & safety procedures 3 Introduction 4 Unpacking 4 Technical Specification 5 CTI/16 & CTI/8 Software version history 5 Test Mode 6 Setting the protocol & baud rate 7 Address setting 8 Advanced features table 9 CTI/8 Connection details 10 Diagnostic LEDs 11 Intellex DVR controlling domes up the coax via CTI/8 telemetry interface 12 DVX to CTI/8 driving RX100/VCL 13 Vicon matrix controlling CTI/8 with 360 Vision domes 14 2060 Dennard domes with up the coax control & 4 local alarms 15 Philips Bi-Phase matrix to CTI/8 driving an RX55X 16 CTI 8 Manual V15.2 July 2010.doc Page 2/20

PRE-INSTALLATI CHECKS AND SAFETY PROCEDURES Unpacking - Inspect the packaging for signs of damage. If damage has occurred, advise the carrier and/or the suppliers immediately. Unpack the receiver carefully and check that all the items are present and correct (see checklist on box). If any item is missing contact the supplier. Retain Packaging - The shipping carton is the safest container in which to transport the unit. Retain undamaged packaging for possible future use. IMPTANT SAFETY PRECAUTIS Read & retain instructions - All relevant safety, installation and operating instructions should be read & retained before attempting to install, connect or operate the unit. Water and moisture - Do not expose the internal electronics of this unit to water or dampness. Power sources - This unit should be operated only from the supplied power supply. Servicing - Servicing of the unit should only be undertaken by qualified service personnel. Damage requiring service - Servicing by qualified personnel should be carried out under the following conditions: (a) When the power supply cord or plug is damaged; (b) If liquid has been spilled, or objects have fallen into, the unit; (c) If the internal electronics of the unit have been exposed to rain or water; (d) If the unit does not operate normally by following the operating instructions. (e) If the unit has been dropped or the enclosure is damaged; Replacement parts - If replacement parts are required, ensure that only replacement parts recommended by the product manufacturer are used. Safety check - Upon completion of any service or repairs to the unit, safety checks should be performed to ensure that the unit is in proper operating condition. Coax grounding - If an outside cable system is connected to the unit, be sure the cable system is grounded. Pre-installation checks - It is recommended that the unit be bench tested prior to installation on the site. Adhere to Safety Standards - All normal safety precautions as laid down by British Standards and the Health and Safety at Work Act should be observed. WARNING TO PREVENT DANGER OF FIRE SHOCK, DO NOT EXPOSE THE INTERNAL COMPENTS OF THIS EQUIPMENT TO RAIN MOISTURE. CTI 8 Manual V15.2 July 2010.doc Page 3/20

INTRODUCTI The CTI/8 is designed to provide conversion from RS422/485 data to BBV Coax Telemetry based systems. Up the Coax telemetry allows upgrading of static cameras to PTZ without the need for additional cabling. It has one RS422/485 input that is dipswitch selectable. The baud rates & parity for Pelco P/D & Vicon protocols are variable. Sixteen individual outputs are provided. Each output connects to a single receiver. Each unit is supplied with a break out box and 0.5m Cat 6 patch cable. Multiple CTI/8s can be cascaded together giving up to 128 camera outputs. Please Note: Camera address will be limited to the maximum number supported by the individual protocol. Please note: Menu Access commands of cameras can vary between control equipment even if using the same protocol. For Example: In Pelco D protocol - dome menu access commands can be either Goto Preset 95 or Save Preset 95. Enter = Goto Preset 1 or Iris Open / Close Protocols currently supported are: BBV, Pelco P/D, Pelco P DM, VCL, Dennard, Philips, Sensormatic RS422, Molynx & Vicon. The CTI/8 has been tested with the BBV FBM/256 Matrix & Starcard Converter, BBV TX1500/96 Matrix & Starcard Converter, Pelco KBD300, DM DS2, VCL VCTM16 Matrix & Maxcom 8 Matrix & Keyboard, Philips Allegiant 32 Camera Matrix LTC8301/50 & Bi Phase to RS232 Converter LTC8780/50, American Dynamics Intellex LT V4 Software, Molynx TTX600 Keyboard & TTX6164T Matrix and Vicon VI411-DVC keyboard Unpacking Inspect the packaging for signs of damage. If damage has occurred, advise the carriers and/or the suppliers immediately. Unpack the interface carefully and check all the items are included: CTI/8 RS422/BBV Coax Telemetry Interface 8 channel CAT6 patch cable Break out box Mounting brackets 9V dc PSU Manual Warranty card X X X X X X X CTI 8 Manual V15.2 July 2010.doc Page 4/20

Technical Specification Power Requirements Inputs 9Vdc 500mA 2 Wire RS485, 2 Wire RS422 Simplex and 4 Wire Full Duplex (input protocol switch selectable) Maximum cable distance: Belden 8723 = 1200m Outputs Facilities 8 x BBV Coax Telemetry Maximum Cable Distance LEDs as power & data indication RG59 = 250m CT125 = 500m Boxed Dimensions Installation Supplied in 19 1 U rack mountable case Length 425mm Depth 110mm Height 43mm The unit is designed to either be fitted into a 19 rack or wall mounted via the fixing brackets supplied CTI/8 Manual & Software Version History Version 15.2 June 2010-1. Change to the Test mode page Version 15A June 2010-1. Change to the Sensormatic commands on page 9 Version 15 11 December 2009-1. Added Test feature. Pan Left & Right via dipswitches Version 1 8 May 2008-1. CTI/8 Released Version 13 15 October 2007-1. Bug fix for address 27 in Dennard RS485 Protocol Version 12 10 October 2007-1. Bug fix for address 2 & 3 in Dennard RS485 Protocol Version 11 3 September 2007-1. Updated Support of VCL Telemetry from Maxcom 8 Matrix -2. Manual Update Version 10 15 August 2007-1. Bug fix of VCL Telemetry from Maxcom 8 Matrix Version 9 10 July 2007-1. Updated Support of VCL Telemetry from Maxcom 8 Matrix Version 8 17 March 2007-1. Updated support of Hash Command release time -2. Manual update Version 7 13 February 2007-1. Added continuous sending of telemetry for legacy coax receivers Version 6 8 January 2007-1. Molynx Protocol Speed table recalibration Version 5 11 December 2006-1. Bug fix for Accumulative Delays in Pelco P & D and Dennard RS485 Routines - 2. Updated watchdog routine - 3. Added support for Sensormatic RS422 Protocol - 4. Added support for Molynx RS485 Protocol - 5. Added support for Vicon RS485 Protocol variable Baud Rate Version 4 18 November 2005-1. Added support for Pelco P/D Protocol variable Baud Rate & Parity settings - 2. Added support for Pelco P DM Auxiliary outputs Version 3 27 June 2005-1. Added support for Dennard 2050 Protocol Version 2 25 May 2005-1. Added support for Philips RS485 Protocol Version 1 11 November 2005-1. CTI/16 Released Support of BBV, Dennard, Philips, Pelco P & D and VCL RS485 input protocols converting to BBV Coax output protocol CTI 8 Manual V15.2 July 2010.doc Page 5/20

Test Mode This feature enables the Camera to be driven left or right from the Coax Telemetry Interface directly. SW2 Sets Test Mode SW1 Sets Camera Number & Direction 7 = Pan Left 8 = Pan Right SW1 Cam 1 Pan Left SW1 Cam 2 Pan Left SW1 Cam 3 Pan Left SW1 Cam 4 Pan Left SW1 Cam 5 Pan Left SW1 Cam 6 Pan Left SW1 Cam 7 Pan Left SW1 Cam 8 Pan Left CTI 8 Manual V15.2 July 2010.doc Page 6/20

Setting the Protocol and baud rate The CTI/8 will only output BBV Coax Telemetry on the 8 Coax output channels The CTI/8 supports various RS422/485 input Protocols SW2 Sets Protocol & Baud Rate SW1 Sets Address & Parity 7 & 8 OFF = None Parity 7 & 8 = Odd Parity 7 OFF & 8 = Even Parity Input Termination SW2 BBV 9600 N 8 1 SW2 Pelco P 9600 N 8 1 SW2 Pelco P 4800 N 8 1 SW2 Pelco P 2400 N 8 1 SW2 Pelco P DM 9600 N 8 1 SW2 Pelco P DM 4800 N 8 1 SW2 Pelco P DM 2400 N 8 1 SW2 Pelco D 9600 N 8 1 SW2 Pelco D 4800 N 8 1 SW2 Pelco D 2400 N 8 1 SW2 VCL 9600 N 8 1 SW2 Dennard 9600 N 8 1 SW2 Philips 9600 N 8 1 SW2 Sensormatic 4800 N 8 2 SW2 Molynx 9600 E 8 1 1 2 3 4 5 5 6 7 7 8 SW2 Vicon 19200 N 8 1 SW2 Vicon 9600 N 8 1 SW2 Vicon 4800 N 8 1 CTI 8 Manual V15.2 July 2010.doc Page 7/20

Address Settings A maximum of 16 x CTI/8 can be cascaded together N.B. Refer to input Protocol documents for maximum address supported i.e. Pelco P max addr = 32 SW1 Sets Address Address Range 1-8 Address Range 17-24 Address Range 33-40 Address Range 49-57 Address Range 65-73 Address Range 81-89 Address Range 97-104 Address Range 113-121 Address Range 129-137 Address Range 145-153 Address Range 161-169 Address Range 177-185 Address Range 193-201 Address Range 209-217 Address Range 225-233 Address Range 242-249 CTI 8 Manual V15.2 July 2010.doc Page 8/20

Advanced Features Table BBV COAX OUTPUT BBV Tx1500 1# 2# 3# 4# START 1 PATROL START 2 PATROL 1# 2# 3# 4# 1 PATROL 2 PATROL START AUTOPAN AUTOPAN PELCO SAVE PRESET 95 PRESET 61 PRESET 33 PRESET 62 PRESET 94 PRESET 63 PRESET 64 PRESET 66 PRESET 67 PRESET 68 VCL PRESET 95 PRESET 61 PRESET 62 PRESET 63 PRESET 64 PRESET 66 PRESET 67 PRESET 67 DENNARD SAVE PRESET 95 PRESET 61 PRESET 33 PRESET 62 PRESET 94 PRESET 63 PRESET 64 PRESET 66 PRESET 67 PRESET 67 PHILIPS AUX 46 PRESET 61 AUX 63 PRESET 62 AUX 100 /OFF PRESET 63 SET 899 PRESET 64 PRESET 66 PRESET 67 PRESET 67 SENSMATIC MOLYNX VIC START PATTERN 3 REPEATED 5 TIMES FOLLOWED BY SAVE PRESET 1 PRESET 61 SEE note 1 AUX 1 PRESET 61 SAVE PRESET 94 95 PRESET 61 START PATTERN 3 REPEATED 5 TIMES FOLLOWED BY SAVE PRESET 1 PRESET 62 SEE note 1 AUX 2 PRESET 62 START PATTERN 3 REPEATED 5 TIMES FOLLOWED BY SAVE PRESET 1 PRESET 63 SEE note 1 HOME PRESET 63 START PATTERN 3 REPEATED 5 TIMES FOLLOWED BY SAVE PRESET 2 PRESET 64 SEE note 1 CAMERA On/Off PRESET 64 PRESET 62 PRESET 63 PRESET 64 PRESET 71 PRESET 66 PRESET 66 PRESET 72 PRESET 67 PRESET 67 PRESET 73 PRESET 67 PRESET 67 NOTE1. 5min time out / Goto Preset 6 to Cancel When using BBV422 & Pelco P you can toggle wash, wipe & lights with Goto Preset commands: Preset 81 Wash on, Preset 82 Wash off, Preset 83 Wipe on, Preset 84 Wipe off, Preset 85 Lights on & Preset 86 Lights off. CTI 8 Manual V15.2 July 2010.doc Page 9/20

CTI/8 Connection Details The CTI/8 unit is supplied with a Cat 6 Patch cable and a Break Out Box. GREEN RED TXB (FROM Controller) = 5 (CAT5) WHITE/BLUE 4 = TXA (FROM Controller) (CAT5) BLUE YELLOW BLACK Connection information RXB (TO Controller) = 6 (CAT5) GREEN BROWN ANGE 3 = RXA (TO Controller) (CAT5) WHITE/GREEN TXA (FROM Controller) DATA + from the DVR/ MATRIX to CTI/8 Gnd = 7 (CAT5) WHITE/BROWN 2 =NC (CAT5) ANGE TXB (FROM Controller) DATA - from the DVR/ MATRIX to CTI/8 WHITE BLUE RXA (TO Controller) DATA + to the DVR/ MATRIX from CTI/8 Gnd = 8 (CAT5) BROWN 1 =NC (CAT5) WHITE/ANGE RXB (TO Controller) DATA - to the DVR/ MATRIX from CTI/8 see RS422 NOTE RJ45 Surface Socket FARNELL No 454-485 RS422 NOTE Some systems require RS422 FULL DUPLEX before they will work. Some Sensormatic systems require a 4 Wire connection. Diagnostic LEDs CTI 8 Manual V15.2 July 2010.doc Page 10/20

LD10 J19 POWER INPUT 9-12 DC 500mA SW2 BBV422 SW1 Address Range 1-8 SW1 SW2 SW1 SW2 J9 02008 iss 3 Bit 7 Tx Termination Bit 8 Rx Termination BBV LD8 LD7 LD6 LD5 LD4 LD3 LD2 LD1 LD10 POWER LED RS422/485 PT LD 10 LD 1-4 LD10 will flash when the CTI/8 is sending data to the coax driver chips, even if there are no video sources. If there are no video sources you will see LD1 to 4 flash in sequence. This is a good way to test if the CTI/8 is connected & configured correctly. When a video source is applied to either input the associated LED will be on constantly. CTI 8 Manual V15.2 July 2010.doc Page 11/20

I Intellex DVR controlling domes UP-THE-COAX via CTI/8 Telemetry interface Sensormatic Mark Mercer JVC TK - C676 Pelco Domes Pelco Esprit Bosch Domes All Dennard Domes Panasonic Aritech LG Domes VCL Honeywell Please note this is a small selection of the domes that can be controlled by the BBV RX100. For a full list of domes please refer to the BBV website www.bbvcctv.com. The CTI can control the full range of BBV Receivers Coax to Dome RS485 to Dome Rx100 RG59 <250m CT125 <500m CTI/8 8 Camera Coax Telemetry Interface R L H T O X Edgeport/1 USB Converter RS232 kit (RS232 to RS422 converter) CTI 8 Manual V15.2 July 2010.doc Page 12/20 Forward Vision

DVX to CTI/8 driving RX100/VCL Rx100 VCL Pelco D 2400 N 8 1 RS422 Simplex Pelco D 2400 E 8 1 RS422 Simplex CTI/8 Coax CTI 8 Manual V15.2 July 2010.doc Page 13/20 LAN DVX LAN IP SWITCH Twisted Pair RS422 Simplex RX100 to Dome Max Distance 5m Max Distance Coax RG59=250m CT125=500m VCL Dome PC with DVX Viwer

VIC MATRIX CTROLLING CTI/8 WITH 360 VISI DOMES Coax Distance 250M RG59 500M CT125 CTI/8 VIC SIMPLEX COAX VIC KEYBOARD NETWK CTI 8 Manual V15.2 July 2010.doc Page 14/20

2060 Dennard Domes with up the coax control and 4 local alarms Rx100 Dennard 250M RG59 / 500M CT125 CTI/8 BiPHASE LTC8780/50 CTI 8 Manual V15.2 July 2010.doc Page 15/20 RS232 RS422/485 RS232 kit

Bi-Phase Coax Philips Bi-Phase Matrix RX55X Multiple protcol telemetry receiver RS232 R X T X CTI/8 CTI 8 Manual V15.2 July 2010.doc Page 16/20 Philips Kbd RS422 SIMPLEX Philips Bi-Phase Matrix to CTI/8 driving RX55X Bi-Phase Coax Philips G3 Dome RS232 kit Max Distance Coax RG59=250m CT125=500m Coax

- Blank for your notes - CTI 8 Manual V15.2 July 2010.doc Page 17/20

- Blank for your notes - CTI 8 Manual V15.2 July 2010.doc Page 18/20

- Blank for your notes - CTI 8 Manual V15.2 July 2010.doc Page 19/20

Extend your BBV Warranty from 12 months to 3 years As of the 1 st September 2008 BBV have offered our customers the opportunity to extend the standard 12 month warranty to 3 years. You must register for the extended warranty within 12 months of the date of manufacture. How to register for the 3 year warranty Registering for the new, longer 3 year warranty term is quick and easy. Either: Complete the warranty application card that comes in the box with your BBV product, and return it FREEPOST to BBV: BBV 3 Year Warranty If this card is returned with the serial number of the product and the Installation company details BBV will extend the warranty period from 12 Months to 36 Months. Number of Units, Start Serial No. Final Serial No. Contact Name. Company Name. Please could you send me information Phone Number. especially on: Site Name. Rx100s Address 1. Rx45x & Rx55x Address 2. FBM Video Matrices Address 3. Tx1500 Video Matrices Post Code. Starcard & Starcard Converters e-mail address. BBV Quad Do you read. Pick A Point I do not require any other further product information, Please refer to WWW.BBVCCTV.COM for terms, conditions & exclusions VAT Reg. No. 621758439 Registered in England No. 2852921 Registered office: 17 Apex Park Diplocks Way Hailsham East Sussex UK BN27 3JU Or alternatively: Register online at: www.bbvcctv.com Simply enter your details on the Warranty Cover page.