Key Features and Functions. General Description

Similar documents
Key Features and functions. General Description

Ps Black (typ.) (typ.) Current Consumption

UA70-R. 20W Ps IMD < -47dB Red Field (without precorrection) 10Wrms shoulder < -36dBc (with precorrection)

20Wrms DVB-T/60W ps UHF Amplifier

15D05A Broadband Solid State Power Amplifier

NuPower Xtender TM VU4GX02 VHF/UHF Solid State Bidirectional Amplifier

05E05A S-Band Solid State Power Amplifier

Instruction Manual Model BlockUpconverter

Instruction Manual Model # Block Upconverter

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

AMIGO- 8VSB (ATSC) digital Modulator

QPC6222SR GENERAL PURPOSE DPDT TRANSFER SWITCH. Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information

Features. Parameter Min. Typ. Max. Min. Typ. Max. Units

TGA GHz 30W GaN Power Amplifier

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Modular Block Converter Systems

ALPAN W Compact DTV Transmitters 3-4U 19 HE DIGITAL ANALOG

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

USB-TG124A Tracking Generator User Manual

TGA2807-SM TGA2807. CATV Ultra Linear Gain Amplifier. Applications. Ordering Information. CATV EDGE QAM Cards CMTS Equipment

TGA2218-SM GHz 12 W GaN Power Amplifier

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Power Amplifier 0.5 W 2.4 GHz AM TR Features. Functional Schematic. Description. Pin Configuration 1. Ordering Information

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

= +25 C, IF= 100 MHz, LO = +17 dbm*

Parameter Min. Typ. Max. Min. Typ. Max. Units

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Features. = +25 C, 50 Ohm System

= +25 C, IF= 100 MHz, LO = +15 dbm*

= +25 C, IF= 100 MHz, LO = +15 dbm*

MULTIBAND 1/3 RACK-MOUNTED

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

4W High Linearity InGaP HBT Amplifier. Product Description

GaAs MMIC Double Balanced Mixer

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

USB Smart Power Sensor

GaAs MMIC Double Balanced Mixer

TGP2108-SM 2.5-4GHz 6-Bit Digital Phase Shifter

OBSOLETE HMC908LC5 MIXERS - I/Q MIXERS, IRMS & RECEIVERS - SMT. GaAs MMIC I/Q DOWNCONVERTER 9-12 GHz. Typical Applications. Functional Diagram

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Parameter Min. Typ. Max. Min. Typ. Max. Units

Parameter Input Output Min Typ Max Diode Option (GHz) (GHz) Input drive level (dbm)

Features. Gain Variation Over Temperature db/ C

TGA2239. Product Description. Product Features. Functional Block Diagram. Applications. Ordering Information. Part No.

DA : Series of Narrowband or Wideband Distribution Amplifiers

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

RF V W-CDMA BAND 2 LINEAR PA MODULE

TGP2109-SM GHz 6-Bit Digital Phase Shifter. Product Description. Functional Block Diagram. Product Features. Applications. Ordering Information

Model /29S RF Splitter

USB Smart Power Sensor

The Hmc869LC5 is ideal for: Point-to-Point and Point-to-Multi-Point Radio. Parameter Min. Typ. Max. Units

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MICROLITHIC DOUBLE-BALANCED I/Q MIXER

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Features. = +25 C, IF= 100 MHz, LO= +13 dbm* Parameter Min. Typ. Max. Min. Typ. Max. Units

2W SDARS ECHO Repeater

TGA2238-CP 8 11 GHz 50 W GaN Power Amplifier

Wide Band Power Amplifier 6GHz~12GHz. Parameter Min. Typ. Max. Units Frequency Range 6 12 GHz Gain db Gain Flatness ±2.0 ±3.

1/3 RACK-MOUNTED BLOCK CONVERTERS

Parameter Input Output Min Typ Max Diode Option (GHz) (GHz) Input drive level (dbm)

= +25 C, IF= 100 MHz, LO = +15 dbm*

Parameter Symbol Units MIN MAX. RF Input Power (CW) Pin dbm +20. LO Input Power (CW) Pin dbm +27

Features. Parameter Min. Typ. Max. Units

RF1119ATR7. SP4T (Single Pole Four Throw Switch) Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Data Sheet. AMMP GHz x2 Frequency Multiplier. Features. Description. Applications. Functional Block Diagram.

Parameter LO RF IF Min Typ Max Diode Option (GHz) (GHz) (GHz) LO drive level (dbm)

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

OBSOLETE HMC215LP4 / 215LP4E. GaAs MMIC MIXER w/ INTEGRATED LO AMPLIFIER, GHz. Typical Applications. Features. Functional Diagram

TGA GHz 5 W GaN Power Amplifier

MICROLITHIC DOUBLE-BALANCED I/Q MIXER

Parameter LO RF IF Min Typ Max Diode Option (GHz) (GHz) (GHz) LO drive level (dbm)

Features. = +25 C, As a Function of LO Drive & Vdd. IF = 1 GHz LO = -4 dbm & Vdd = +4V

Features. = +25 C, Vdd = +7V, Idd = 820 ma [1]

SYNTHESIZED COMMUNICATION CONVERTERS

Absolute Maximum Ratings Parameter Rating Unit VDD, CTLA, CTLB, CTLC, CTLD 6.0 V Maximum Input Power TX1 (GSM850/900), 50Ω +37(T AMB =25 C) dbm TX2 (G

GaAs DOUBLE-BALANCED MIXER

HIGH-LINEARITY TRIPLE-BALANCED MIXERS T3-0838

MICROLITHIC DOUBLE-BALANCED MIXER

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

MICROLITHIC DOUBLE-BALANCED MIXER

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

TGP Bit Digital Phase Shifter

MICROLITHIC DOUBLE-BALANCED I/Q MIXER

GaAs DOUBLE-BALANCED MIXER

6 GHz to 26 GHz, GaAs MMIC Fundamental Mixer HMC773A

v SUCCESSIVE DETECTION LOG VIDEO AMPLIFIER (SDLVA) 1-20 GHz Features Parameter Conditions Typ. Units Input Frequency Range 1-20 GHz

GaAs DOUBLE-BALANCED MIXER

THALNA. 600W Air Cooled DTV Transmitters HE UHF 1HPA

MICROLITHIC DOUBLE-BALANCED MIXER

TGL2209 SM 8 12 GHz 50 Watt VPIN Limiter

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

HMC-C078. SDLVAs. Features. Typical Applications. General Description. Functional Diagram

GaAs MMIC High Dynamic Range Mixer

Transcription:

AU301-DP Product Name GR03490 Manufacturer's Part Number Technical Specification Summary Frequency Range 470-862MHz Typ. Gain 56 db P1dB 1900 W Typ. Efficiency > 40% At 1dBcp Analogue TV 1400 Wps Temperature Range -5 to + 45 ºC DVB 430 Wrms Max VSWR 3:1 DTV 560 Wrms Working Class AB Two tone 1600 Wpep Supply Voltage 43,0 V Key Features and Functions Full LDMOS Power Amplifier 1400 W ps Out 430 Wrms Out DVB-T DTV (8 VSB): 560Wrms BroadBand (470-862 MHz) No internal cabling Easy maintenance without special tools RS232-RS485 interface Control software included Extremely strong mechanical structure Requires external PSU (see PS200-D series from Res-Ingenium) General Description AU301-DP is a full LDMOS Broadcast Power Amplifier specifically designed for digital applications. The unit is the state of the art in terms of easy assembly, reliability and performances. The complete unit is compliant to all relevant international standards. Actual Power Amplifier Picture Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 1 of 10

Electrical Specifications Parameter Min. Typ. Max Units Notes Frequency 470 862 MHz Full coverage without tuning P1dB 1900 W In CW mode Power 1600 W PEP 2 tones, 1 khz spacing (-30 dbc) IMD3-33 dbc 2 tones, 1 khz spacing (1,6 kw PEP) Power Input 7 dbm Max value in CW mode @ 1dBcp Gain 56 db At 1600 W PEP / 430 W rms DVB-T V Supply 43 Vdc By External Power Supply Drain Current 80 Adc For 1600 W PEP Drain Current 63 Adc For 430 Watt rms with DVB-T signal Input return loss -14-16 db Phase Variation ± 10 º Unit to unit Gain Variation ± 2,0 db Fine ADJ available F2 Second Harmonic -35-25 dbc F3 Third Harmonic -45-30 dbc Baseplate Temp. -10 +75 ºC Video Parameter Min. Typ. Max Units Notes Analog Power 1400,0 W ps Common amplification IMD -55,0-50,0 dbc At 1400 Wps, inside the Channel [#] Differential Gain 3,5 6,0 % Error at 1400 Wps [#] Lum. Non Lin. 4,5 7,0 % Error at 1400 Wps [#] Differential Phase 2,0 4,0 Deg. Error at 1400 Wps [#] ICPM (peak to peak) 2,5 5,0 Deg. Error at 1400 Wps [#] Digital Power (DTV ) 560,0 W rms Digital Power (DVB-T) 430,0 W rms M.E.R. (DVB-T) 30,0 db Shoulders (DVB-T) -33,0-35,0 dbc At ± 4.2 MHz / 360 W rms Shoulders (DVB-T) -30,0-33,0 dbc At ± 4.2 MHz / 430 W rms [#] Analog TV signal, dual sound (-13, -20 dbc) RED field, without Precorrection All Specifications are valid for load impedance 50 Ohm, Vdc=43.0Vdc, Idrain=78A max ABSOLUTE Maximum Ratings Parameter Value Units Notes Output Power 1500 W in CW mode Input Power 7,0 dbm in CW mode Operating Voltage 50 Vdc Stable operations 43 Vdc Bias Current 10,0 A Quiescent current for four LDU661 pallets Drain Current 90 A with Tj @ 175 ºC (see the Device data) VSWR 2:1 All phase angle / High Mismatch Protection set @ 2:1 Storage Temp. -20 + 80 ºC Base Plate temp. 75 ºC Heatsink Temperature Electrical Interfaces RF input RF output RF Monitor RS232 RS485 Local Enable Local Enable N female on Rear Panel 7/16 DIN female on Rear Panel SMA connector on Rear Panel Dsub 9 Pin on front and rear panel Dsub 9 Pin on rear panel Switch front panel Two-pole connector on the rear panel Remote control ENABLE RF Enable / Disable (On / Stand By) Note: An output on the rear panel can manage the external Power Supply ON/OFF. The external PS will be switched OFF in case of alarm Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 2 of 10

Mechanical specifications AU301-DP General data and layout Dimensions. Physical Dimensions Weight Air flow 19 Inch x 3 Units x 600mm (23,62") depth 25 kg. / 55.0 Pounds 500 cubic meters per hour at max fan speed. Front Panel Functions RS232 RESET Mains Vdc Rear Panel Connections RF Out Gain Adjustment ENABLE Switch External Enable Derating Fault RF Monitor 1 2 3 4 External Senses -VDC Poles 1 EXT. ENABLE GND RS232 2 GND RF Input 3 P.Supply Enable +VDC Poles RS485 4 +5Vdc +43 Volt Impedance Selector Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 3 of 10

READABLE DATA BY REMOTE COMPUTER OR CONTROL LOGIC UNIT (via RS232 / RS485) Parameter Alarms / Status Enable ON / STAND BY RF Faults ACTIVE if Gain < 6dB referred to nominal C max ACTIVE when RF Thermal Protection is ON Pin max ACTIVE when RF Overdrive Protection is ON VSWR max ACTIVE if VSWR max Protection is ON Max Current (I max) ACTIVE when Current is too high Parameter Alarms / Status Measurements RF Power Input RF Power Output RF Power Driver RF Temperature RF Temperature 2 VDC IDC Final 1 IDC Final 2 IDC Driver Input level expressed in [micro Watt] Output level expressed in [Watt] Driver level expressed in [Watt] RF Heatsink Temperature expressed in C (half section) RF Heatsink Temperature expressed in C (half section) Main Power Supply / Input Voltage Supply Current of half section (two LDU661) expressed in Ampere Supply Current of half section (two LDU661) expressed in Ampere Supply Current of Predriver and Driver expressed in Ampere Self Protection Thermal Protection Overdrive High Output Mismatch Max Current High Temperture protection Pin max must be set on the working channel with the used DVB-T signal VSWR max must be set on the working channel with the used DVB-T signal High Current protection External High Power Supply Technical Specifications V out I out Load Regulation Output Ripple Sense Enable 43 Volt DC 2 x 30 A or 1x 60 A with DVB-T signal 3 x 30 A or 1 x 90 A with Analog TV signal ± 0.5% from 10% up to 100% dynamic load change 400mV max External Sense for both sections (if double). Sense Impedance 6.8 KΩ each positive/gnd wire AU301-D provides a signal 0/5V (0 = disable; 5 = enable). Open collector with internal pull-up. This signal must be used to enable the power supply. External Service Power Supply Technical Specifications V out I out Load Regulation Output Ripple Enable 5 Volt DC 0,5 A ± 0.5% from 10% up to 100% dynamic load change 50mV max This voltage must be present anytime to power the logic control unit. Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 4 of 10

Graphs and Charts Plot 1. Typ S21 small signal Gain, and S11 Input Return Loss Plot 2. Typ S21 RF Monitor vs Main Output Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 5 of 10

Plot 3,4,5. Typ. Two Tone Test @ 1600 Watt PEP. 400 Watt CW each Carrier, 1 khz spacing Test condition: VDC=43 Volt 3 rd order IMD measurements Freq. Pout PEP 3 rd order I total [MHz] [Watt] [dbc] [A] 470 1600-34,50 72,0 660 1600-33,83 77,0 862 1600-38,05 78,0-31,00-32,00-33,00-34,00-35,00-36,00-37,00-38,00-39,00 470 660 862 Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 6 of 10

DVB-T Typ. Performances @ 360 Watt rms Output (without precorrection) CH F. [MHz] Shoulder I Total P. coms. Eff. @ -4,2 @ +4,2 [A] [Watt] [%] 21 474-32,85-33,82 51,40 2210,2 16,29 31 554-34,53-35,92 55,20 2373,6 15,17 41 634-34,06-37,55 56,50 2429,5 14,82 51 714-36,29-37,43 49,80 2141,4 16,81 61 794-33,29-34,65 46,90 2016,7 17,85 69 858-35,92-35,92 48,90 2102,7 17,12 Shoulder [dbc] -25,00-27,00-29,00-31,00-33,00-35,00-37,00-39,00 21 31 41 51 61 69 Channel -4.2MHz +4,2MHz Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 7 of 10

DVB-T Typ. Performances @ 430 Watt rms Output (without precorrection) CH F. [MHz] Shoulder I Total P. coms. Eff. @ -4,2 @ +4,2 [A] [Watt] [%] 21 474-29,95-30,58 62,20 2674,6 16,08 31 554-33,47-35,85 61,90 2661,7 16,16 41 634-32,05-33,43 59,90 2575,7 16,69 51 714-34,32-35,71 51,40 2210,2 19,46 61 794-33,26-32,72 52,70 2266,1 18,98 69 858-33,35-33,24 53,40 2296,2 18,73 Shoulder [dbc] -25,00-27,00-29,00-31,00-33,00-35,00-37,00 21 31 41 51 61 69 Channel -4.2MHz +4,2MHz Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 8 of 10

Integration and important Operating instructions The AU301-DP is designed for operation up to 430Wrms (DVB signal) with very high linearity, and TV Analog Signal up to 1400 Watt peak synk, in common amplification, dual sound. This design uses 6th generation family LDMOS devices that are capable of very high peak power as long as the average power does not exceed specified ratings. The devices are protected by an internal circuit, for Overdrive and high Mismatch load. However is mandatory to handle with care the Input level during the "precorrection operations" due to possible very fast and high spikes coming from the source. The AU301-DP must allow the nominal voltage before applying RF driver signal or damage can result to the amplifier. For this reason the voltage must be applied before the RF driver signal. Additionally, the input signal, must be removed before powering down to prevent damage to the amplifier. You can accomplish this by removing the RF driver signal and powering down the power amplifier. The AU301-DP has not the internal Power Supply. It must be supplied by an external Power Supply following the P.S. supply indicated on this document. RES-Ingenium can provide two kinds of Power Supply: - PS200 series equipped with 1 kw slots - PS200-D3 @ 43 Volt (equipped with 3 Slots) for any Digital Operations - PS200-D6 @ 43 Volt (equipped with 6 Slots) for any TV Analog Operations and CW - Compact 43Volt / 4kW Power Supply (19 Inch, 2 HE) for any operation In case of installation in a site with no air filter is strongly reccomended to buy the "Air Filter Kit Accessory" coeded as GR04190 easy to install on the front panel. When the AU301-DP in installed in a 19 Inch std Rack is important to leave a right space on the rear zone to facilitate the exhausted air extraction. It's suggested to leave one free unit (1 HE) at the top of the Amplifier. In case of use of more AU301-DP in parallel an appropriate power combiner has to be used. The connection between the Amplifiers and Power Combiner Input Ports is strongly reccomended to use"low Loss Cables" type. The Amplifier is equipped with an RF Monitor Output available by a SMA connector where is possible to test the performances when the it's on duty. The RF Monitor Output is normally > -40 db referred to the main output in order to have a right signal managed by std Instrumentation. Anyway a SMA pad can be put in series to reuduce the RF monitor amplitude. The Amplifier is delivered in cartoon box packaging. Use all professional caution during unpacking, handling and mounting. Please consult RES-INGENIUM factory with any integration questions. Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 9 of 10

Ordering informations Product Name Manufacturer's Part n. Feature Description AU301-DP GR03490 Standard version GR04190 AIR FILTER KIT Notices and Warnings Res-Ingenium Via dei Vasari, 17 Zona Industriale Fontanelle di Bardano 05018 Orvieto (TR) - ITALY Telephone: +39 0736 316333 Fax: +39 0763 316002 Internet: res-ingenium.com E-Mail: sales@res-ingenium.com V.A.T. reg.n. 01359920558 IMPORTANT NOTICE RES-INGENIUM RESERVES THE RIGHT TO MAKE CHANGES TO THE PRODUCT(S) OR INFORMATION CONTAINED HEREIN WITHOUT NOTICE. RES-INGENIUM ASSUMES NO RESPONSIBILITY FOR ANY ERRORS WHICH MAY APPEAR IN THIS DOCUMENT. WARRANTY INFORMATION APPLICABLE TO THE PRODUCT IDENTIFIED HEREIN IS AVAILABLE UPON REQUEST. NOTHING CONTAINED HEREIN SHALL CONSTITUTE A WARRANTY, REPRESENTATION OR GUARANTEE OF ANY KIND. RES-INGENIUM EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS AND/OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY, AND OF FITNESS FOR A PARTICULAR PURPOSE, USE OR APPLICATION. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Res-Ingenium. WARNING RES-INGENIUM PRODUCTS ARE NOT INTENDED FOR USE IN LIFE SUPPORT APPLIANCES, DEVICES OR SYSTEMS. USE OF A RES-INGENIUM PRODUCT IN ANY SUCH APPLICATION WITHOUT WRITTEN CONSENT IS PROHIBITED. Release Date 24/06/2009 File: AU301-DP_Datasheet_Rev 3.xls Page 10 of 10