Surface Mount Installation Manual

Similar documents
Surface Mount Installation Manual

A Division of Impact Lighting STAR PANEL INSTALLATION MANUAL

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

White Only. Twinkle Stars INCLUDED IN ALL KITS: 12 VOLT POWER SUPPLY 3 DRILL BITS TEMPLATE REFERENCE INCLUDED IN BELOW MODULES TL-FBK TL-CLB-FWK

PRODUCT MANUAL. Chroma Flow PRO RGB LED Controller. and Receiver. Product Description. Main Functions: This manual reviews: Receiver.

Cable System Installation Guide

TROV TROUBLE SHOOTING GUIDE. A comprehensive trouble shooting guide for TROV

INSTALLATION INSTRUCTIONS FOR

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

LeRIBSS MTC MANUAL. Issue #1. March, MTC Control Unit Definitions, Information and Specifications. MTC Control Unit Electronic Schematics

PROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

MP Maker Pro Mk.1. Quick Start Guide

ISE, Inc Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440) B Long Ranger Timer

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

1:8 CAT5 Distribution Amplifier

CAT EXT-CAT USER MANUAL

INSTALLATION MANUAL. ION Series FIBER OPTIC ILLUMINATOR IP67 OUTDOOR RATED

2178-L/S Series Fiber Optic Splice Case with Gasket

White Paper. Discone Antenna Design

IP-LINX. Installation Guide

USER MANUAL. GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

TV Lift System Model CL-65 Installation Instructions

NEO-STB-0004 Neo-Flash 300 RGB User Manual

QUICK INSTALLATION GUIDE

Projector Lift. User Guide INSTALLATION OPERATION SETUP PROGRAM IR REMOTE FACTORY RESET

VGA Extender LR EXT-VGA-141LR. User s Manual

NewScope-7A Operating Manual

DVI DL Super Booster Plus EXT-DVI-141DLBP. User Manual

IP-LINX Fiber :: X-XXXX

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

6000 Series Patch Panel Terminating Instructions

FOSC 450 C6 and D6 Closures

Installation Guide AT-HDR-EX-70-2PS

Stand Alone Serenity, Light, Sound, Rain Head

GENUINE PARTS CAUTION

RADIO FREQUENCY SYSTEMS

Optical Distribution Box 300 Installation Guide. Version : R0.0

Nanoleaf Light Panels

CAT Extender. EXT-CAT User Manual.

Absolute Rotary Encoder E6CP

ICS Digital Menu. Installation Guide Version 1.1

DX-10 tm Digital Interface User s Guide

VGA Extender LR EXT-VGA-141LR. User s Manual

Caution. Hanging the Screen:

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Master Clock Controller. User Guide. pyramidtimesystems.com

Manual. Simrad IS80 Heading Repeater HR80. English

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

MAKE AN RGB CONTROL KNOB.

Starling Tab-Tension 2 Series

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

Lumencove Family. The highest quality light from the tightest spaces

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

18mm ECAM Cable Entry Port

Motor Operated Solar Shade with Valance Installation and Care Instructions Complete Video Instructions Available Online at

Installation Instructions

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide

Video Wall Installation Guide User Guide

DD E SIG N E D & E N GIN EE R E. Holman Garden Lights App Instruction Manual. Android Android manual

Telecommunications Service Technician

Fiberglass - Technical Data

Model#: IN-DI2MIRF 2MP Indoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Follow The Leader In Shielded Technology

Master Clock Controller. User Guide. pyramidtimesystems.com

INSTALLATION INSTRUCTIONS

SPECIFICATION SHEET lumencove

Master Clock Controller. User Guide. pyramidtimesystems.com

Electric Motorized Projection Screen PowerMax Tension Series

Star Series Star Floor Kit (CLSSFK25-50 or CLSSFK50-50) LED driven Fiber Optic Lighting

Part names (continued) Remote control

Instruction Manual for Electronic Blowers and Flashboards

IPad 4 REPAIR GUIDE. Version Edition

3M Locator Plate N

HDMI Over IP Extender Kit - 4K

IPad 3 (glass) REPAIR GUIDE. Version Edition

Cellular Signal Booster

Service manual Cantano W/T

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m)

Satellite Dish Installation Manual (Ver. 2) 1

MS2540 Current Loop Receiver with RS485 Communication

4x4 Component Matrix over CAT-5

Multi-Media Installation Guide

3M Distribution Box (DDB)

Channel Cable Tray - Accessories

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

Hardware installation

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

Transcription:

Surface Mount Installation Manual VER 3.17

CONGRATULATIONS FOR PURCHASING EPIC SKY TECHNOLOGY STAR PANEL TM. WELCOME TO THE WORLD OF FIBER OPTIC STAR LIGHTS. Your package should include the following: Acoustical fiber optic panels Mounting anchors Low voltage jumper cables Lead wire(s) Hex tools poker tool Anchors template 12V power supply Cove lighting spacers (optional not always used. Spacers are used with the Thin-glow LED system.)* * Some installers use spacers for standard installation requireing more room for wires. Note: Sometimes there will be more than one lead wire and sometimes the wire(s) will already be attached to the power supply. POWER SPECIFICATIONS: Each panel draws 12V and 2.5W, or 0.2 amps max. Note: Some panels will come with a shooting star, which contain two (2) Epic Sky Technology Star Panel Board light sources and will increase the panel another 2.5W, for a total of 5W. TIP: Put latex gloves on to keep panels clean when handling. INSTALLATION (with 2 people using a stepladder): Square up the room. A room may look square, but it doesn t mean that it is square. Measure twice since all the panels are aligned off of the first panel. It s alignment in the room is critical. Being just a little out of square with the first panel could result in being way out of square when you get to the end of the room. Take your time squaring up the first panel. Using masking tape, pencil marks, and chalk lines will assist you in keeping the installation square and true. Locate where your first panel will be installed. RUNNING THE POWER: Based on site conditions and project design, there will generally be two options for power. The recommended way is to use a Remote Driver and pre-install a Epic Sky Technology Star Panel Leader Cable, or pre-wire an 18 AWG wire. TIP: After you finish running the power, after lead wires run, test every panel before it goes up, by plugging lead wire to the LED board, located in the center of the panel. REMOTE DRIVER The power supply has connectors for a power cable for the input of the line voltage. The selected outlet for powering the Driver should be controlled from a remote switch, or control system. (Not for controllable stars, these need constant power) Locate the Driver in a proper equipment area that is accessible and within 50 feet of the first Epic Sky Technology Star ceiling panel (generally in the center of the ceiling.) At this point, connect the Epic Sky Technology Star Panel Leader Cable and start daisy chaining the panels together, using the supplied Jumper Cables. Your leader cable should not be longer than 50 feet. Consult with a Epic Sky Technology Star Panel manufacturer if a longer leader cable is required. -1-

MOUNTING THE FIRST PANEL TIP: You can use a paint brush extension (available at most hardware stores) to hold the panel in place. Place the first panel on the ceiling and square in its proper orientation. (This should be performed by at least two people) Push the awl (poker tool) through the center of the round stickers to make an indent in the ceiling. This is done from the finished fabric side of the panel. Once all mounting points are marked on the ceiling, remove the panel. You may use our templates to guide you, please see page 5. TIP: While installing the panels, keep the plastic covers of the un-installed panels on so dust doesn t get on them (especially in construction areas.) See Chart A and Chart B STANDARD PANEL CHART (POWER CHART) A B POWER NO. OF SUPPLY PANELS 25W 10 panels 45W 18 panels EXAMPLE OF 25W POWER 60W 24 panels SUPPLY PANEL WIRING 80W 32 panels 100W 40 panels 150W 60 panels Power Supply 200 W 80 panels 250W 100 panels 300W 120 panels Epic Commander *If you have more than 120 panels, (upgraded unit to send communication) please contact us for assistance. CAT 5 BLUE CABLE (30FT.) Epic Power Adapter II (PE-PA2)(included) IN Advanced Rs232 Controller OUT PE-PA2 18/2 CAT 5 YELLOW CABLE (30FT.) PREWIRED EPIC LUMI LIGHTS PREWIRED EPIC LUMI LIGHTS MD MD SB SB PREWIRED EPIC LUMI LIGHTS PREWIRED EPIC LUMI LIGHTS MD MD SB SB MD = MINI DRIVER (EP-MD2) SB = STAR BOARD LED RIBBON CAN BE CONTROLLED & WIRED DIRECTLY TO THE EPIC ADVANCED RS232 CONTROLLER

INSTALLATION STEPS: Step 1. Position panel. Mark its location. Pa n e l Ex t e n s i o n optional: sold seperately Po s i t i o n p a n e l. M a r k i t s l o c a t i o n. Step 2. Put masking tape on panel face at anchor locations (optional). Position template: push scratch awl (poker tool) through panel at template marking hole. Indent wallboard behind panel. NOTE: To mark Harder wall material, i.e. concrete block, after marking the panel with the scratch awl, put a common nail in the hole and tap with it. Te m p l a t e For more details on marking the Star Panel please view page.7 After Step 2, remove panel Step 3. Screw Epic Sky Technology panel anchors to wall at pre-marked locations. (Consult manufacturer for recommended fasteners to use with anchors. Note: do not over-tighten. Anchors should be hand tight and able to turn on screw shaft. Step 4. Push hex insert firmly into anchor body. 4.1 Push pointed hex driver through panel to engage Epic Sky Technology Star Panel anchors. You can view installation video using anchors at the following address: http://www.epicskytech.com/install_gallery.html

TM TM Step 5. Re-position panel. Connect the lead wire to the LED board of the first panel Note: fully engage hex driver with metal insert before turning. Step 6. Turn Feature Presentaions Star panel anchors counter-clockwise (left) while pushing panel towards wall. Remove masking tape. Lightly rub fabric to hide hole locations. Note: 1 to 2 turns, do not over-tighten. Note: Our panel anchors have been tested to have a pullout strength exceeding 45 lb. in standard 6 lb./ft. 3 fiberglass insulation board. INSTALLING ADDITIONAL PANELS Leave the jumper hanging off the side of the first panel so you can connect the next panel. Because of the flat design of the Jumper Cable plugs, you can sandwich the Jumper Cables between the ceiling and panel, or run them along the 2 light cove on the back of all Surface Mount Panels. You may find that using white gaffers tape, glue dots, or double sided tape helpful in organizing the Jumper Cables during installation. Up to 12 Epic Sky Technology Star Panels can be connected together in any configuration per lead wire. If your installation requires more than 12 Epic Sky Technology Star Panels, then add an additional Leader Cable. The total quantity of panel depends on power supply size. NOTE: See Power Chart on Page 3 for power supply recommendation. Multiple lead wires may be necessary with one power supply (not included in package).

EPIC SKY TECHNOLOGY STAR PANEL 8 IN & 6 IN ANCHOR TEMPLATE MAY BE USED A S A PROTRACTOR ON PANEL. IF THERE IS A FIBER OR OBSTRUCTION YOU MAY GO AROUND IT AND SCREW IN ANCHOR. USE YOUR JUDGEMENT. Note: Some install anchores at 4 inches away, please use your discretion. STEP 1 A) Place anchor template on any corner of the Star Panel and mark the area at 8 inch for anchor installation B) Place anchor template on any side of the Star Panel and mark the area at 6 inch for anchor installation STEP 2 Poke a hole with the Poker tool on the marked areas. STEP 3 Fasten the anchor to the ceiling; use a hex tool to turn anchor to adhere the star panel to the ceiling. * Used also for marking speaker and downlight light areas on the Star Panel.

IF USING CUT-OUT TEMPLATE (NOT INCLUDED IN STAR CEILING SYSTEM) This template is a universal marking guide and cut-out stencil used for marking the center of a down-light, vent, speaker, or any hole that needs to be marked and cut in a Epic Sky Technology Star Panel. Secure the large thumbtack in the center of the Cut-out Template using double-sided tape. Then use double sided tape or thumbtacks to hold the template centered on the ceiling over the opening or area you need to cut out. Properly align the panel and push it up into the thumbtack(s) (Thumbtacks do not come in the package.) Take the panel down, note the location of the thumbtack mark on the back of the panel. Mark the location of the hole on the fabric face of the panel. Now flip the panel over so it is fabric side up. Place the template centered over the hole and insert the awl. Now you have the template so that it rotates around the awl. Note: The circumference of the hole that is required (this hole should be slightly larger than what is required for the fixture opening, but smaller than the fixtures trim ring.) Place the hot knife in the appropriate slot on the template, and slowly rotate the hot knife and template all the way around the cut and cinch the fabric. Remove the awl and template, peel off the fabric circle and use the serrated knife to cut the two inches of insulation. Your perfectly located hole is done.

COMMAND SHEET Epic Sky Technology - LED Star Board (9600 8 N 1) All commands must be terminated by a carriage return. Commands are repeated out the serial port to pass to the next controller or device. The *E symbol means that those command values are stored in EEPROM and will load on power up Command Action Notes ess Scintillation Scintillation Sparkle Mode es1 Sparkle Stars sparkle es2 Sparkle Fast Stars Sparkle Fast es3 Sparkle Really Fast Stars Sparkle Really Fast esr Rain Shower Stars in Rain Shower mode est Party Mode Stars all on with strobe/fade out pattern esldxxx *E Stars on Solid xxx is the level, 1-255, 255 is the brightest ecn Constellation On Solid All LED s on solid - separate than star commands ecs Constellation Sparkle Constellations sparkle eco Constellation Off Only Constellations turn off eclvxxx *E Constellation Solid Level xxx is the level, 1-255, 255 is the brightest! Trigger Shooting Star Immediately trigger shooting star ssq Shooting Star 10 Seconds Shooting Star every 10 seconds, Adjustable via RS-232 ss1 Shooting Star 1 Minute Shooting Star every minute ss2 Shooting Star 2 Minutes Shooting Star every 2 minutes ss5 Shooting Star 5 Minutes Shooting Star every 5 minutes ssz Shooting Star 10 Minutes Shooting Star every 10 minutes sso Shooting Star Off Boards in shooting star mode will turn off ssg Shooting Star On Shooting star on mso Meteor Shower On Meteor Shower mode (DIP switches must be set correctly) Default rate is every 2 minutes msf Meteor Shower Off Stops the meteor shower ssd Power on Setting Return to Power on DIP Switch Setting esdmxxx *E Dim Setting (stars only) Brightness level of stars, 1 to 255, Default is 255 (brightest) espkxxx *E Star Sparkle Speed Sparkle Speed, 0-255, default is 17, the higher the number, the slower the sparkle mtspxxx *E Meteor Shower Speed xxx is the The Speed of the Meteors in the Shower, 0-255, Default is 50 (higher is slower) mttmxxx *E Time Between Meteors Time in 1/10 s of a second between each meteor in the shower (0-255) default is 7 mtinxxx *E Meteor Shower Interval Time in seconds between meteor showers (0-255) default is 120 mtnmxxx *E Meteor Number Number of meteors per shower (1-255) default is 19 ssspxxx *E Shooting Star Speed xxx = 0 (fastest) to 254 (slowest), default is 40 sstmxxx *E Shooting Star Interval Interval Between Shooting Stars in seconds, 0-255, Default is 10 eso Stars Off All Stars Off esn Stars On Turns on the stars in the last mode they were in globalloff All Off All Stars off, regardless of mode *NOTE* The Epic Star Boards will read the DIP switch setting on power up, check that the boards are in the right mode before installing in a ceiling.

EPIC STARS DIP SWITCH SETTINGS The E C STA BOA D odel allo a ariety o e ect incl ding Star E ect ( parkle cintillation rain tro e etc ) and pecial e ect ( hooting tar eteor ho er) The Dip S itch et the progra (Shooting tar 10 Min etting i ho n in pict re) Mode Switch 1 Switch 2 Switch 3 Switch 4 Scintillation Up Up Up Up All on 50% Down Up Up Up All On 25% Up Down Up Up Meteor Shower Down Down Up Up Sparkle Up Up Down Up Sparkle Fast Down Up Down Up Sparkle Really Fast Up Down Down Up Constellation Mode Down Down Down Up Shooting Star 10 Sec Up Up Up Down Shooting Star 1 Min Down Up Up Down Shooting Star 2 Min Up Down Up Down Shooting Star 5 Min Down Down Up Down Shooting Star 10 Min Up Up Down Down Rain Mode Down Up Down Down Party (Strobe) mode Up Down Down Down All on 100% Down Down Down Down *NOTE* The Epic Star Boards will read the DIP switch setting on power up, check that the boards are in the right mode before installing in a ceiling. Note: All commands need to be followed by a carriage return (/r) and not a new line.