medlab One Channel ECG OEM Module EG 01000

Similar documents
LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

SignalTap Plus System Analyzer

Advanced Test Equipment Rentals ATEC (2832)

Hardware & software Specifications

4 MHz Lock-In Amplifier

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

LAUREL ELECTRONICS, INC.

Product Information. EIB 700 Series External Interface Box

2 MHz Lock-In Amplifier

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

TL7650/TL7651/TL7652 Dual HD-SDI / DVI(HDMI) Output Video Transceiver. TL765x Series Features. Block Diagram TL7650. Dual HD-SDI + DVI(HDMI)

SingMai Electronics SM06. Advanced Composite Video Interface: DVI/HD-SDI to acvi converter module. User Manual. Revision th December 2016

WaveDriver 20 Potentiostat/Galvanostat System

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

3-in 1- out DVI Switcher

High Speed Data Acquisition Cards

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface

SC24 Magnetic Field Cancelling System

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

Synthesized Clock Generator

VIDEO ALARM VERIFICATION UNIT VIVER

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

Noise Detector ND-1 Operating Manual

SDI-MP1010-GM-60P-M-RA 3G/HD-SDI Output Video Transceiver. SDI-MP1010-GM-60P-M-RA Features. Block Diagram SDI-MP1010-GM-60P-M-RA.

TL8651 3G/HD-SDI Output Video Transceiver. TL8651 Features. Block Diagram TL8651 3G/HD-SDI. 1080p p50

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

SC24 Magnetic Field Cancelling System

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Aegis Electronic Group

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

VBOX 3i Dual Antenna Measures Slip and Pitch/Roll (RLVB3iSL)

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

Operating Instructions Rev. No. 4.1 July 07, LTC and VITC Reader with Serial Interface TC 60 RLV

ET-YFB100G S P E C F I L E. Digital Interface Box. As of December Specifications and appearance are subject to change without notice.

Configuration Vestas VMP3500

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

EGM Einthoven Goldberger Module Type 701

Transmitter optics with 9x white light LED (optics cover made of glass)

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

VBOX3i Dual Antenna. Measures Slip and Pitch/Roll (RLVB3iSL) Features

Variable gain and stable detection even at high gains

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

VBOX 3i. 100Hz GPS Data Logger (VB3i-V3) Features

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

What is sync? Why is sync important? How can sync signals be compromised within an A/V system?... 3

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Technical data. General specifications. Indicators/operating means

User Manual POE. Twisted Pair POE Extender

WaveNow USB Potentiostat / Galvanostat

Development of an Analog ECG Simulator using Standalone Embedded System

GFT Channel Digital Delay Generator

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

HDS-21RS Owner s Manual 2 x 1 HDMI Switch with Scaling

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

User Manual DVM-HDBT-EX3

TL7050 Dual 3G/HD-SDI + DVI(HDMI) Output Video Transceiver. TL Features. Block Diagram TL7050. Dual 3G-SDI + DVI(HDMI) Output

TransitHound Cellphone Detector User Manual Version 1.3

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

HITACHI. Instruction Manual VL-21A

TempScan/1100 & MultiScan/1200

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

RS-232 to Multi-Mode Fiber Optic Media Converter

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

EEG CB1512 Caption Legalizer & Relocating Bridge

WaveMaker III Gartech Enterprises Inc. 12/17/2012

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

TL7050 Dual 3G/HD-SDI + DVI(HDMI) Output Video Transceiver. TL Features. Block Diagram TL7050

PicoScope 6407 Digitizer

Experiment 9 Analog/Digital Conversion

L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

VGA Port. Chapter 5. Pin 5 Pin 10. Pin 1. Pin 6. Pin 11. Pin 15. DB15 VGA Connector (front view) DB15 Connector. Red (R12) Green (T12) Blue (R11)

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

Portable in vivo Recording System

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

R&S ZVA110 Vector Network Analyzer Specifications

OPTICAL POWER METER WITH SMART DETECTOR HEAD

EEG A1452 SCTE-104 Inserter Frame Card

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

BeneHeart R3. Electrocardiograph

PROLINX GS7032 Digital Video Serializer

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

VBOX 3i Dual Antenna RTK

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

SPECTRO Series SPECTRO-3-50-FCL. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 10)

Transcription:

medlab One Channel ECG OEM Module EG 01000 Technical Manual Copyright Medlab 2012 Version 2.4 11.06.2012 1 Version 2.4 11.06.2012

Revision: 2.0 Completely revised the document 03.10.2007 2.1 Corrected error in S command description 31.05.2008 Corrected wave samples numerical range 2.2 Corrected amplitude definition 14.07.2008 2.3 Corrected typing errors 2.4 Changed manufacturer address 11.06.2012 Copyright Medlab 2012 All rights reserved Medlab does not assume any responsibility for use of the product described, no patent licenses are implied and Medlab reserves the right at any time without notice to change said product and specifications. For the most current product information visit us at www.medlab.eu. Version 2.4 11.06.2012 2

Contents Mechanical Dimensions, Overview 4 Scaling and Physical Units 5 Specifications 6 Connector Assignment 7 Serial Transmission 8 Software Protocol 9 PC Test Program 10 Filter Adjustment 11 Regulatory Considerations 12 3 Version 2.4 11.06.2012

Mechanical dimensions of the module 77.3 74.7 27.3 2.54 5.08 3.1 33.8 49.6 52.5 2.8 3.3 Mechanical drawing of the PCB. All values are in mm. Overview The scope of this document is the description and specification of Medlab s ECG board EG1000. It will help anybody who is familiar with programming and medical electronics to integrate the board into their own electronic system. The EG1000 measures one channel of a patient s ECG using a three lead cable. What is actually measured is the differential input voltage between the red and yellow input clamps of the cable. These leads carry the differential voltage to the input stage of the amplifier, the third lead, usually coloured in green. It is the isolated ground of the module and it should not be connected to the mains ground of the medical system (neither protective nor functional earth). The EG1000 has a fully IEC601 compliant isolation on board, and if properly integrated, can be used to develop a medical device of type CF isolation class. No connections except those to the patient cable shall be made on the input side of the module (see drawing on the next page). Possible applications include: Basic ECG monitoring, triggering of CT systems, triggering of ultrasound systems, triggering of lithotripters, ECG recording in labs or university classes aso. Version 2.4 11.06.2012 4

Isolation barrier; do not mount or connect anything here JP 1 Connector for serial interface 2 1 16 1 JP 2 Connector for patient cable Do not connect any electrical equipment except for the patient cable on this side Scaling and Physical Units The scaling of ECG curves is traditionally done in the physical unit "cm/mv" for the y-axis and "mm/sec" for the x-axis. This is a remainder from the times when the amplified signal was written directly on paper using strip recorders. Since it is not defined what kind of display is interfaced by the user to the EG01000, we use the direct AD converter values (0 to 255) for the y-axis and the numbers of sample points sent per second for the x-axis (s -1,Hz) in this description. The zero line is always in the middle of the range, e.g. 128 or 0x80. For the medium amplification stage (A1), a 1mV signal is equal to 75 steps, e.g. the signal swings between 90 and 165. For the low amplification stage (A0) the resolution is half as high, e.g. the 1mV signal swings between 110 and 147. For the high amplification stage (A2), the 1mV signal s amplitude lies between 50 and 200. The traditional resolutions for the time axis are 12.5 mm/sec, 25 mm/sec and 50 mm/ sec. The three most commonly used ranges for the amplification are 2 cm/mv, 1 cm/mv and 0.5 cm/mv. 5 Version 2.4 11.06.2012

Technical data (Specifications) Mechanical data: See page 4, board drawing. 77x52.5 PCB, max. thickness 10 mm Attachment: Four M3 screws. Nylon screws are recommended Weight: 28 g Operating voltage: 5 Volt, +- 10 % Power consumption: Input: Isolation: Patient Isolation: Amplification: Data transmission: Filtering: Maximum DC offset: 26..30 ma (150 mw) while measuring Defibrillation protected 4000 Volts RMS CF Three levels, user selectable Three transmission speeds, 50/100/300 Hertz 50 Hz and 60 Hz notch filter included 300 mv Amplifier frequency range: 0.3 to 30 Hz. Pulse detection: Protocol: Connector: 30.. 250 bpm +- 1%, +- 1 Digit, 8 beat averaging Bidirectional serial protocol at 9600 Baud (8,N,1) 16 pin interface connector, 2 rows of 8 pins, 2.54 mm Version 2.4 11.06.2012 6

Connectors (see drawing on page 4 for location) Header for host connection: JP1: 1 Ground 2 Ground 3 Txd (TTL level) 4 Txd (RS232 level +- 5 Volt) 5 Rxd (TTL level) 6 RxD(RS232 level +- 5 Volt) 7 Not connected 8 Not connected 9 Not connected 10 Not connected 11 Not connected 12 Not connected 13 Shutdown, VCC level here powers down whole board 14 Not connected 15 VCC input 16 VCC input Header for patient cable connection JP2: 1 Positive input 2 Not used 3 Patient ground 4 Not used 5 Negative input Three Lead Patient Cable Shield Shield Shield yellow black red Left Arm Right Leg Right Arm yellow black red Left Leg Right Leg Right Arm yellow black red Left Leg Right Leg Left Arm Einthoven I Einthoven II Einthoven III 7 Version 2.4 11.06.2012

Serial Transmission The module connection is done by serial, asynchronous communication at 9600 baud, 8 data bits, one stop bit, no parity bit. Both CMOS (0..5 volts) and RS232 (+/- 5 volts) voltage levels are available. The RS232 levels are helpful during the evaluation of the board. This can be done using any PC and a special software. It is recommended to do the connection in the final system using the CMOS levels, since this saves parts and energy on the host side of the data stream: No level translators are needed on the host side. The EG01000 sends a continous data stream and receives commands. Commands are one byte characters, some of them have one byte as additional parameter, others are executed after the ECG board receives the command byte alone. There is a command that changes the number of ECG trace sample values sent per second ("S", like "speed"). This command takes one byte between "0" (ASCII 0x30) and "2" (ASCII 0x32) as its parameter. Command "A", like "amplification" also requires one parameter between "0" and "2" to switch the amplification of the ECG amplifier of the module. Command "M", like "mode" brings the module into an internal simulation mode, where no real samples, but a previously stored waveform is transmitted to the host. Sending "N" like "normal" returns the module to the normal state. This is extremely helpful during the integration of the board into the host system. Command "C", like "calibration", switches the trace to a 1 mv reference curve for about 1 second. After that, the module returns to send ECG sample values. Commands "5" and "6" change the internal notch filter of the module to 50 or 60 Hz. The module powers up with both amplification and speed set to level 0, which means lowest amplification stage and transmission of 300 sample points per second. Simulation mode is off at power up, the notch filter is set to 50 Hz. The neutral line of the ECG always lies at 128, the module transmits unsigned byte data. While a lead off condition is active, a pulse value of 0 and a neutral line of 128 are being transmitted. Version 2.4 11.06.2012 8

Serial Transmission Protocol All data is transmitted at 9600 baud, 8 bits, 1 stop bit, no parity. Each time a pulse is detected by the board s internal algorithm, a block with a new, averaged pulse rate is transmitted. The pulse detector is of high quality, and the point in time when the pulse marker (0xFA) is transmitted can be used for triggering applications that require to synchronize other devices to a patient s R-wave. The ECG wave sample points are transmitted continuously with 50, 100, or 300 bytes per second, according to the user s last command. The curve sample points lie between 0 and 246. Values that are higher than 246 (0xF6) are used for marking the following byte as a new data value according to the following definitions: Marker byte Meaning of following byte(s) Commands accepted by the module 0xF8 0xFA 0xFB 0x11 wave sample points follow Pulse value follows Info byte follows The only info byte defined is 0x11, "LEAD OFF" Others may be added in the future "M" switch to simulation mode "N" switch back to normal mode "S" "0" send ECG trace with 300 Hz "S" "1" send ECG trace with 100 Hz "S" "2" send ECG trace with 50 Hz "A" "0" amplification stage 0 "A" "1" amplification stage 1 "A" "2" amplification stage 2 "5" turn on 50 Hz notch filter "6" turn on 60 Hz notch filter "C" calibrate, send 1mV pulse Definition of data stream sent by the module Example of a received data stream at the host side: 0xF8 0x20 0x23 0x25 0xFA 0x80 0xF8 0x25 0x25 0x26,... Wave Marker ECG sample points Pulse = 128 Wave Marker ECG Sample points Time This data stream is simple to decode, has nearly no overhead and is still self-synchronizing in case a byte is lost during transmission. 9 Version 2.4 11.06.2012

Test Program For easy integration of the module into medical systems, a test software has been made available. The EG01000 can be connected directly to a PC, the received data is shown on the screen. To run the program, connect the EG01000 board to the serial port of a PC. If the PC has no serial port, please use a USB to RS232 adapter and install the driver of this adapter first. Connect the power input to a 5 volts DC source. Then start the program on your PC and select the serial port number in the "Port" menu. Commands can be sent to the board by pressing the command buttons in the application. Since the same software can be used for EG01000 and the three channel EG01010 board, some buttons have no function when used with the EG01000. The software is available free of charge under: www.medlab.eu, on the page that describes the EG01000. The software is written in Visual Basic 6 and the source code is also included in the download package. Version 2.4 11.06.2012 10

Filtering The bandwidth of the filter for the ECG signal is always a compromise between signal stability and fidelity in the reproduction of the real form of the ECG: The critical part is the highpass filter that eliminates the drift of the trace due to DC voltages building up at the electrodes. On our ECG board, this filter can be adapted by changing R1 or C1 on the board. The -3db frequency of the highpass can be calculated with the formula: f = 1/(2* PI * R1 * C1). When the board is delivered, this frequency is adjusted to 0.30 Hz by using 150 nf for C1 and 3.3 Megohm for R1. R1 C1 Regulatory considerations The module described in this document is not a final medical product. That means that it cannot be used as a standalone unit to do measurements on a patient. Therefore, the EG01000 is not CE-marked. The customer has to undertake the procedure of CE-marking with the final product that he develops using the PCB. However, due to the large experience, Medlab is able to support customers during the certification process. The device is not 510k registered, which is not possible for a module. Only final products that will be sold in the USA have to - and can - undertake the process of 510K approval. 11 Version 2.4 11.06.2012

medlab medizinische Diagnosegeräte GmbH Helmholtzstrasse 1 76297 Stutensee (Karlsruhe) Germany Tel. +49(0)7244 741100 support@medlab.eu www.medlab.eu Version 2.4 11.06.2012 12