Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Similar documents
Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Technical Information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Technical Specifications

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Patriots Theater at the War Memorial Technical Data

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

The ACT Facility Technical Specifications Main Stage Information

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Sandusky State Theatre Technical Specifications

SHUBERT THEATER 247 College Street, New Haven, CT

Concert Hall Technical Specifications

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Main Stage Technical Specs - Hall #2

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Technical Services and Specification

Concert Hall Technical Specifications

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specifications

Technical Data Sheet

Technical Specifications and Inventory Spring 2018

Shouson Theatre Venue Specifications (updated Jan 2017)

Dr. Fred Speckeen Theatre. Information and Technical Specifications

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Main House Technical Specification

Technical Specifications

Dale F. Halton Theater Technical Specifications

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

SAINT ANSELM COLLEGE DANA CENTER

TECHNICAL SPECIFICATIONS

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Schauer Arts and Activities Center Technical Information Touring Companies

Theatre Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Bloomington Center for the Performing Arts. Technical Specifications

Z SPACE Technical Specifications. Stage & Rigging

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Vern Riffe Center for the Arts Technical Information Packet for Users Seating capacity Stage configuration CONCERT HALL PROSCENIUM THEATER

Ferst Center for the Arts Technical Specifications (Revised May 2016)

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Marjorie S. Deane Little Theater

Downtown Arts Center Tech Packet. General Information

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Technical Specifications. Taylor Little Theater

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Anvil Theatre. Technical Information

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Technical Information

Technical Specifications

2017 TECHNICAL SPECIFICATIONS

DOMINO THEATRE INC. THEATRE TECHNICAL SPECIFICATIONS AND INFORMATION

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Arcadia Performing Arts Center Technical Specifications and Information

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Quick-Advance Fact Sheet

Dinkelspiel Auditorium - Technical Specifications

Performing Arts Theatre

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

CENTRE FOR PERFORMING ARTS

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Specification Pavilion Dance

TECHNICAL PACKAGE.

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

THE MORTENSEN HALL. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Technical Specification

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

SECREST AUDITORIUM TECHNICAL PACKAGE

Jane Mallet Theatre Technical Specifications

Matt Dann Cultural Centre

NORTH CHARLESTON PERFORMING ARTS

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

VENUE TECHNICAL REQUIREMENTS

NORTH CHARLESTON PERFORMING ARTS

TECHNICAL INFORMATION & SERVICES

Technical Specifications

Powerhouse Theatre technical information and general specifications 2017

The Fredericton Playhouse Studio 686 Queen street * e3b 1c

Visy Theatre technical information and general specifications 2019

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Theatre Technical Specifications

HORIZON STAGE TECH PACKAGE September 2018

Theater Technical Information

The Breen Center for the Performing Arts Saint Ignatius High School

The Bailey Theatre Technical Data

EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE

Transcription:

GENERAL THEATRE INFORMATION: Stage Floor: Dance Floor: HALL: Standard Stage: Sprung hard wood, painted black. Pit area: Nivoflex adjustable risers, hardwood ply top. Pit area is not sprung. Note: Neither standard stage or pit area may be drilled, screwed, nailed or stapled into Harlequin reversible black/grey floor. Panels run upstage/downstage when installed to a maximum depth of 37 (11.28m). Normally used with standard stage extended by three rows of pit area (31 (9.45m) from U.S. gallery to D.S. edge). Use of rosin is not allowed on either surface. Ladders: One (1) Upright 24 AWP One (1) 10 step ladder Two (2) 6 step ladder Dressing Rooms: There are Four (4) dressing rooms at the basement level. Each room has mirrors with lights around their perimeter. There are two (2) shared washrooms with a toilet and sink. There is one (1) shared shower Dressing Room 1 four (4) people, one (1) sink Dressing Room 2 eight people, two (2) sinks Dressing Room 3 two (2) people, one (1) sink Dressing Room 4 two (2) people, no sink Please note: Dressing rooms can accommodate more people than indicated. Laundry/Wardrobe Room: Theatre Personnel: Coin operated washer and dryer, $1.00/load, quarters only. Also equipped with domestic iron and board, steamer, one (1) large sink and costume racks. Minimum technical crew consists of a Head Electrician, an Audio Engineer and a Stage Carpenter. Other personnel may be added in consultation with, and at the sole discretion of the Production Manager. Seating: 422 Maximum capacity in full round. 354 in Standard Proscenium set up. The stage/seating relationship can be changed to suit your performance. This must be coordinated in advance with the Manager, Technical Production. Please be aware that seats cannot be sold until this information is provided. LOAD IN: The theatre is located at 231 Queens Quay W., access at Lower Simcoe St. The loading dock is on the north side of the building, is at standard dock height and can accommodate a 26 truck. The loading dock door has a maximum opening of 85 x 85 (2.16m x 2.16m). Page 1 of 5

STAGE: On-stage Dimensions: NOTE: ALL CRITICAL DIMENSIONS SHOULD BE MEASURED ON SITE Depth Standard (rear gallery to pit line) 22 0 (6.7m) Depth Gallery to gallery(house and stage) 66 4 (20.19m) Depth upstage wall (under gallery) to back of house 79 9 (24.30m) Width gallery pipe to gallery pipe 27 0 (8.22m) Width gallery face to gallery face 28 0 (8.53m) Width wall to wall (under galleries) 40 0 (12.19m) Height stage to bottom of first gallery 7 7 (2.31m) Height stage to bottom of second gallery 15 11 (4.84m) Height stage to tech. gallery 25 11 (7.89) Height stage to grid 39 0 (11.88m) Stage Door Openings: Up Stage Left 78"W x 78"H (1.98m x 1.98m) Up Stage Right 71 W x 79 H (1.8m x 2m) Pit Dimensions: Depth 21 5 (6.55m Width 27 9 (8.45m) Riser Units 361/2" x 83" (.93m x 2.11m) Moveable levels 0'0", -8",-16",-24",-33"(0cm, -20cm,-41cm,-61cm,-84cm) Wing space: Storage space: Extremely limited. Audience sightlines project to the offstage walls (red brick). Limited. Small backstage area includes crossover. Stage Drapes: Main Curtain: none (may use traveler) Legs: 4 pairs 8' x 29'6" (2.43m x 8.99m) 1 pair 3 x 29 6 (0.91m x 8.99m) Borders: 4-12' x 29'6" (3.65m x 8.99m) o 1 11 x 29 6 (3.35m x 8.99m) o 1 10 x 296 (3.05m x 8.99m) Traveler: 1 w/track 28' w x 26' h (8.53m x 8.99m) Scrim: Black 28' x 26' (8.53m x 7.92m) Cyclorama: (cotton) 28' x 29'6" (8.53m x 8.99m) Fly System: There is no fixed fly system. Overhead grid allows fairly flexible rigging points however scenery moving during a show has specific challenges. All rigging must be discussed in detail with the Manager of Technical Production at least eight (8) weeks in advance of your show. PROPERTIES: (15) Music Stands with lights (12) Chairs Tables by prior arrangement. Property inventory is subject to change. Please confirm with the Harbourfront Centre Theatre Manager, Technical Production that all items will be available for your event. OAD Page 2 of 5

LIGHTING: Control Location: Control room at back of house - first Gallery Control System: ETC ION with fader wing (Operated only by Harbourfront Centre personnel.) 2 DMX 512 outputs for control of 1024 dimmers/attributes. 10000 cues 1000 groups 999999 macros 10000 Presets 2 timed/manual fader pairs and 40 submasters/40 pages 4 encoder wheels Rate and level wheels, Master slider and black out button Dimmers: Lighting Instruments: Strand CD80. 192 dimmer per circuit system, 1801.2Kw and 222.4Kw. (18) 12 Colortran leko 1K (6 iris) (20) 20 Colortran leko 1K (32) 30 Colortran leko 1K Please note that fixture must be disassembled to install the iris kit. Iris units have a slightly smaller beam spread. (17) 40 Colortran leko 1K (18) 6" Colortran fresnels 1K (6) CCT fresnels 1K (Mounted on floor stands) (24) ETC SOURCE IV PAR 750w (16) PAR 64 Note that the 4 groups of 3 ETC pars on the upstage Tech. Gallery and third catwalk are the "House Plot" and must be restored if moved. (24) Source IV 50/ 575W (14) ETC 26 Source Four (10) ETC 36 Source Four Colortran & Source IV Lamps - Type "A" Gobo PAR 36 house lights under all catwalks (18) 25 surrounding pillar strip lights 15 watts house lights (6) LCG Pin Spots. *ALL HOUSE LIGHTS CONTROLLED BY SEPARATE PENDANT. NOT TIED INTO DMX SYSTEM* All connectors are 20 amp twist (Nema L5-20) VIDEO: Control Location: Control room at back of house - first Gallery Control System: SANYO PLC-WM550L 5.5k lumen projector (1) 12 x16 4:3 front projection screen (2) 12 x16 4:3 Rear projection screen Fixed position centre of Catwalk #2 VGA HDMI Page 3 of 5

SOUND: Control Location: Control room at back of house - First Balcony Console: DigiCO SD9 24 motorized faders. Drive Rack with 48 inputs. MADI DigiGrid Mic input, LRM outputs and group outputs are 3 pin XLR, pin 2 hot. P.A.: House: (4) Meyer UPA-1 via two Meyer Ultraseries M-1Processors (2) Subwoofers - Meyer USW via one Meyer Ultraseries B-1 processor (Mono) Monitors: (8) Apogee AE3m monitors Amplification: (3) Ashley FET 2000 (House) (2) Labgruppen 4ch (Monitors) Microphones and D.I. s: (6) Shure SM-58 (6) Shure Beta-58 (4) ShureSM-57 (2) Shure Beta-57 (1) Shure Beta 52 (3) Shure Beta 56a (2) Shure SM 94 (4) SEN. 421 (6) SM-81 (2) AKG D-112 (1) SM-99 (4) AT 5100 Condenser (3) Crown 160 PCC (4) Countryman active DI's (1) J48 Active DI (1) JDI Passive DI (4) Sennheiser EW135G3 Wireless w/handheld & Laveliers. (2) DPA 4099 geadset microphones for wireless mics Playback/Record: (1) Denon DN-C635 CD Player (1) Denon DN4500 Dual CD Player (1) Tascam CD-RW700 Recorder Signal Processing: (4) Klark Teknics DN 360 (1) PreSonus ACP88 comp/gate (2) SPX 2000 Reverb COMMUNICATIONS: Intercom: 6 belt packs and head sets 3 wireless belt packs and headsets. Program and Program sound to dressing rooms, booth and FOH. Paging Paging to dressing rooms from U.S.R. and booth Page 4 of 5

Page 5 of 5