STRUCTURED CABLE SYSTEM (SCS)

Similar documents
California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

SECTION FIBER OPTIC STATION CABLES

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION TESTING OF COPPER CABLES

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

SECTION COMMUNICATIONS HORIZONTAL CABLING

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

CHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus

CABLING STANDARDS FOR

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Section Communications Optical Fiber Backbone Cabling

DESIGN!!GUIDELINES!!!!!

Multi-Media Installation Guide

SECTION 7 -- CROSS-CONNECT SYSTEMS

B. All work shall be in accordance with Building Industry Consulting Services International (BICSI) guidelines.

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

ADDENDUM NO. 2 This addendum consists of 8 pages. Kenai Peninsula Borough Purchasing & Contracting

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

Telecommunication Infrastructure Project September 20, 2002

SECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

The University of Texas at Austin September 30, 2011

Volition TM RJ45 K5e Jacks

Target Interface / Construction Compliance Inspection Checklist

Division 27 COMMUNICATION/DATA, PATHWAYS, AND WIRING

Liberty Mutual Structured Cabling Specification Bid and Build Structured Cabling Technical Specification for:

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

LITWARRANTY Rev. 5 W a r r a n t y P r o g r a m S t r u c t u r e d C a b l i n g S y s t e m s

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

UNM IT/Telecommunications Guide Specification Labeling 11/07/

Request for Purchase DESIGN AND INSTALLATION OF STRUCTURED COMMUNICATIONS CABLE SYSTEMS

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

PREMIUM 5e F/UTP PRODUCTS

SECTION CONTROL, COMMUNICATION AND SIGNAL WIRING

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

HDBT Installation Guide

Cable Installation Tips

A. The requirements of Section govern the work specified in this section.

SECTION COMMUNICATIONS HORIZONTAL CABLING

Technical Specifications Florida Gulf Coast University

Project No. # Page 1

DS1 Cross-Aisle Panel

SOLICITATION ADDENDUM NO. 1 ITB THE FOLLOWING CHANGES TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED.

Request for Quote E- Rate Eligible Services Scope of Work - Wireless LAN and Cabling for Access Points

WJHW, Inc. 6 April 2016 Texas Tech University Issue for CD Set Sports Performance Complex Lubbock, Texas

STANDARDS SECTION (16651) COMMUNICATIONS DISTRIBUTION SYSTEM (Rev. Jun 2011)

Cable Installation Tips

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cable Management and Ladder Rack

Information Technology Services DESIGN AND INSTALLATION STANDARDS

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

Family Health Centers, Inc. Request for Proposal. for. Family Health Centers East Broadway Data and Communications Cabling Project

SPECIAL SPECIFICATION 8540 Telecommunication Cable

Telecommunications Cabling System Technical Specification for the K-12 Educational Environment Enhanced Category 5

Edition 1, August 2011 Copyright 2011 Smart-e (UK) Ltd.

DATA/TELECOMMUNICATIONS REQUEST FOR PRICING

Public Works Division Lighting District Fiber Optic Specifications April 2009

user guide SLX-111 also available: SLX-100, SLX-214 transmitter & receiver pair tel: +44 (0) ,

Request for Proposal (RFP)

UTP ACTIVE TRANSCEIVER HUB

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

PLU-TV & AT&T CATV CLASSROOM/OFFICE BUILDING EQUIPMENT LISTS & DIAGRAMS CLT CATV.doc CENTER FOR LEARNING & TECHNOLOGY (CLT)

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

SPECIAL SPECIFICATION 6559 Telecommunication Cable

Primex Wireless, Inc. July, Wells Street Lake Geneva, WI

SECTION 686 VIDEO DECODER DESCRIPTION

DSX-1 Cross-Connect Procedures

Underground Installation of Optical Fiber Cable by Pulling

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE AND COMPONENTS. January 20, 2017

Effective earthing of screened cables

SECTION COMMUNICATIONS STRUCTURED CABLING

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

CATEGORY 6 CABLING SOLUTIONS

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0553 Identification for Communications Systems

CATEGORY 6A CABLING SOLUTIONS

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

Request for Quote E- Rate Eligible Services Scope of Work Network Infrastructure and Structured Cabling

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

SECTION O FIBER OPTICS

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE AND COMPONENTS. July 19, 2013

Mfgr. Berk Tek ea , Berk Tek ea , Berk Tek ea. Berk Tek ea ,350.

Aerial Cable Installation Best Practices

SECTION COMMUNICATIONS CABLING. (Sub-Sub-Bid Required, Part of Sub-Bid Section ELECTRICAL)

SECTION TELECOMMUNICATIONS FIBER OPTIC DISTRIBUTION

CATEGORY 6A CABLING SOLUTIONS

Transcription:

PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated or to be incorporated in such construction and all services, facilities, tools and equipment necessary or used to perform and complete such construction. The work of this section shall include, but is not limited to, the following: 1. A complete structured cabling system composed of Category 6 unshielded twisted pair station cabling system with all cables, termination hardware, outlets and necessary installation and supporting hardware in accordance with the strictest manufacturer written recommendation, the specification, and Cal Poly ITS Telecomm Labeling, Design & Syntax Standards in Appendix B. 1.02 QUALITY ASSURANCE A. Refer to Section 27-00-00 for general details. B. As noted in Section 27-00-00, all contractors and installers working on structured cabling system elements shall hold a current manufacturer s certification for each individual component they install. 1.03 CODES, STANDARDS AND GUIDELINES A. Except as modified by governing codes and by the Contract Documents, comply with the applicable provisions and recommendations in Section 27-00-00. B. The Cal Poly ITS Telecom group, Telecommunications Standards Document and the Labeling, Design and Syntax Standards in Appendix B. 1.04 SUBMITTALS A. Refer to Section 27-00-00 for general details. B. Shop Drawings: 1. None Required C. Submit Manufacturer s Cut Sheets for the following: 1. Any products not specifically listed in the PRODUCTS section shall require a submittal of the manufacturer s cut sheets and approval by the Cal Poly ITS Telecomm group. D. Manufacturers Testing: 1. Submit as testing results as required by Section 27-08-13. E. Documentation supporting the proposed warranty and all terms and conditions. F. All certifications (individual and company) as required by guarantor of the above mentioned warranty shall be submitted. These certifications shall only include those persons with direct association with this project and includes the expiration date and full name of each individual for which the certification is issued. 1 of 6

1.05 IDENTIFICATION A. Cable labels shall be placed on both ends of all cables. B. 1 white nylon with black lettering cable labels. C. Labels containing a unique cable number shall be placed on both ends of all cables, 6 inches from the termination and/or terminal block. (See the Cal Poly ITS Telecomm group Labeling, Design and Syntax Standard in Appendix B) D. Subsequent to placing and terminating cables, the Contractor shall place the appropriate cable label on all cables as defined above. E. If at any time during the job the cable label becomes illegible or removed for whatever reason, the Contractor shall immediately replace it with a duplicate pre-printed cable label at the Contractor s expense. F. All cable labels shall be easily accessible, both physically and visually, upon completion of the job. G. Refer to Section 27-05-53 for additional details. 1.06 DEFINITIONS A. N/A 1.07 WARRANTY A. Refer to Section 27-00-00 for general details. B. All components used in horizontal cabling systems shall be warranted for a minimum period of 20 years from the date of installation against defects in materials, equipment and workmanship. This warranty shall also include the performance of these systems. This warranty shall include transmission requirements as specified in applicable ANSI/TIA/EIA/IEC/ISO standards for each cable system specified. This warranty shall also include all current and future applications designed for and available for each cable system. PART 2 PRODUCTS 1. Warranty shall be guaranteed by a single reputable manufacturer: 2.01 PRODUCT CONSISTENCY a. AMP, Inc. or Cal Poly ITS Telecomm group approved equal A. Product Consistency: Any given item of equipment or material shall be the product of one manufacturer throughout the facility. Multiple manufacturers of any one item shall not be permitted, unless specifically noted otherwise. 2.02 COPPER STATION CABLES GENERAL A. Cable jacket marking: Must be legible and shall contain the following information: 1. Manufacturer s name and/or trade mark 2. Copper Conductor Gauge 3. Pair Count 4. UL listing 2 of 6

5. Category rating 6. Sequential distance markings, in one foot increments 2.03 CAT 6 HORIZONTAL CABLE A. UTP Station Cable for voice and data: 4 unshielded twisted pairs of 23 AWG solid copper conductors. Individually insulated conductors under a common sheath. B. Cable must be plenum rated. C. Cable must meet requirements for Category 6 of ANSI/TIA/EIA-568 D. Station cable jacket shall be white. E. Approved Manufacturers: Commscope, Belden, Hitachi, AMP, Belkin or Cal Poly ITS Telecomm group approved equal PART 3 EXECUTION 3.01 GENERAL A. Location and placement of termination blocks, patch panels and other distribution hardware shall be shown on the Drawings or defined therein. B. All cross-connects shall be installed by the Cal Poly ITS Telecomm group after all station cable test reports have been reviewed and approved. C. Station cable shall be designed and installed such that the installed length (Permanent Link) is a maximum of 290 feet from faceplate to the patch panel in the ER/TR. (See Fig. #161 in Appendix B) 3.02 QUANTITIES A. Quantities of system elements shown on the drawings shall be illustrative only and are meant to indicate the general configuration of the work. The Contractor shall be responsible for providing the correct quantities of materials to construct a system that meets the intent of these Specifications and the relevant codes. 3.03 INSTALLATION A. The Contractor shall install each cable as an uninterrupted conductor section between the designated termination points, unless otherwise directed by the cable installation specifications. There shall be no splices or mechanical couplers installed between the cable points of origin and termination. B. Unless otherwise noted, all cables shall be routed through the building ITS Telecomm cable tray or conduit. C. All horizontal cables shall be plenum rated except where run under the slab or exposed to moisture. Cables run under the slab or exposed to moisture shall be OSP cable, see 27-13-14 for more details. D. Non-telecomm cable runs shall not be tie-wrapped to any Structured Cable System supporting devices (including cable trays, wire basket, conduit, etc.), except when supported by ladder racking within the EF/TR/ER. E. At the same time cable is pulled into a pathway, also install a pull string to facilitate future cable pulls. 1. Pull string shall be nylon with 210 lb. pulling tension. Pull string is to be tied off at each end. 3 of 6

F. Install station cabling, faceplates and jacks as detailed in the Specifications and Drawings. The typical configuration for faceplates shall be three unshielded twisted pair (UTP) cables of 4 pairs each, in nonresidential spaces unless otherwise noted. Structured cable shall be terminated to a jack or plug of the proper Category using the 568A termination standard. (See the Cal Poly ITS Telecomm Labeling, Design & Syntax Standards in Appendix B) G. Non Typical Station Outlets: 1. Security Cameras, Wireless Access Point Locations, Wall Phones, Card Access Devices, Key Boxes and other special use outlets/faceplates shall require differing quantities of station cables, have different termination requirements and shall require approval in writing in advance by the Cal Poly ITS Telecomm group. 2. See section 27-15-43 for termination details, and see Drawings for specific location details. H. Terminate all four pairs of each cable on one faceplate 8p8c jack. I. Leave 15 of slack for each cable measured from the face of the wall, at each jack location. J. Leave 6 of slack at any transition or pull point to maintain cable bend radius, and prevent damage to the cable. K. Leave 12 of slack for the pull string at the faceplate end, and 36 of slack at the far end of the pathway. L. Cable Termination 1. Station cable shall terminate in a specific EF/TR/ER designated on the Drawings to serve that location. 2. Station cable shall terminate on the proper distribution panel in the appropriate TR/ER equipment rack. 3. Leave a minimum of 6 of slack for each cable at the point of termination. 4. Maintain pair twists of Station cable up to the point of termination. Under no circumstances shall cable pairs be untwisted or otherwise altered prior to termination. 5. Do not bend Station cables to a radius of less than four (4) times the cable diameter. 6. Cabling installation shall meet all manufacturer s written instructions. 7. See Specification Section 27-11-19 for more detail on patch panel terminations. 3.04 GROUNDING & BONDING A. N/A B. Refer to Section 27-05-26 for additional details. 3.05 TESTING A. For testing details see Section 27-08-13 3.06 ACCEPTANCE A. Upon receipt of the Contractor s documentation of testing, Cal Poly ITS Telecomm group representatives will review/observe the installation and may randomly request tests of the cables/wires installed. Once the installation and testing has been completed and the Cal Poly ITS Telecomm group representative is satisfied that all work is in accordance with the Contract 4 of 6

Documents, the representative will notify the Contractor and/or Cal Poly Project Manager in writing or via email. 3.07 RECORD (AS-BUILT) DRAWINGS A. The Project Record Drawings shall show the types and locations of all Station cabling. Drawings shall include identifying information from the cable identification labels. END OF SECTION 5 of 6

DOCUMENT VERSION CONTROL REVISION DATE AUTHOR REASON 1 02/20/2014 R. VOLK INITIAL DOCUMENT RECREATION 02/20/2014 DW&MH PRIMARY REVIEW COMPLETE 6 of 6