Film Capacitors Power Factor Correction

Similar documents
Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Power over Ethernet Transformers 60 W series

Film Capacitors Power Factor Correction

Film Capacitors AC Capacitors Application note

SAW components. SAW RF filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Base stations LTE band 27. Date: October 31, 2016 Version: 2.

Power Factor Correction Power Quality Solutions

Power Factor Correction Power Quality Solutions

3 line filters for converters and power electronics

EMC filters. 4-line filters for installations and systems Rated current 6 to 125 A. Date: January 2006

KRF EMC Filters Installation, Operation and Maintenance Manual

MIKRO POWER FACTOR CORRECTION COMPONENTS

Filters for Power Lines (Low Leakage Current)

POWER FACTOR CORRECTION

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

Surface Mount Multilayer Ceramic Chip Capacitors for High Frequency

Surface Mount Multilayer Ceramic Chip Capacitors for High Temperatures 200 C

Capacitors and banks 50 Hz 0 400/415 V network voltage

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

TRF STEP-DOWN TRANSFORMER USER MANUAL

LED MODULES READYLINE DL

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Instructions. P MHz 1X/10X Passive Probe

Price List. AC-mfd Capacitors.

Horn loudspeaker, Ex proof, short/long flare

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

AC Line Rated Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Product Data Sheet 8506 VW-691

Technical Information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Indoor Linear 80W Driver SI-C215280N2KR

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

Pendant Light Fitting IEC Series 6470/2

Operating instructions

Emergency lighting units EM powerled

R.2. Power capacitors, LV. Power factor correction and harmonic filtering. Homepage : Circutor-NRW Büro Köln

LED control gear Compact fixed output

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

TRISHALA ELECTROLYTICS PVT LTD BANGALORE

Trusted 40 Channel 120 Vac Digital Input FTA

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Emergency lighting units EM powerled

Model Number Structure

LED Driver Compact fixed output

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Colour Explosion Proof Video Camera USER MANUAL VID-C

LED Driver Linear / area fixed output

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LED Driver Compact fixed output

Gear Pump Units For single-line centralized lubrication systems

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Installation instructions Ex frames

Datasheet - SRB301LC 24VAC/DC

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Datasheet - SRB-E-201ST

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Installation instructions Cable transit device Roxtec RS ES Ex

LED Driver Compact dimming

Power Injector 1520 Series

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

llen-bradley 194R-HM4-NFPA3

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Trusted 40 Channel 120 Vac Digital Input FTA

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

Video Accessory IC Series Sync Separation ICs with Built-in AFC BA7046F, BA7071F Rev.A 1/9

Jul03 Rev C EC

Ordering details. Approval. Classification

Keysight 16048G/H Test Leads

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Modular pulse operated latching relay 16 A

Transcription:

Series/Type: Ordering code: Date: January 2018 Version: 9 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF. Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! Identification/Classification 1 Film Capacitors Power Factor Correction (header 1 + top left bar): Identification/Classification 2 (header 2 + bottom left header bar): Ordering code: (top right header bar) Series/Type: (bottom right header bar) Preliminary data (optional): Department: CAP FILM P PM PFC Date: January 2018 Version: 9 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company.

Construction Dielectric: Polypropylene film Non-PCB, Semi-dry biodegradable resin Extruded round aluminum can with stud Degree of protection: IP00 (optionally IP54 with terminal cover; additional cable gland at cable entry required) Features Single-phase, provided with discharge resistors Double safety system: overpressure disconnector, self-healing technology Naturally air cooled (or forced air cooling) Indoor mounting Typical applications For Power Factor Correction Terminals Fast-on terminals B32300A* series Screw terminals B32301A* series7 Mounting Threaded stud at bottom of can (max. torque for M12 = 10 Nm) Technical data and specifications Characteristics Rated capacitance C R Tolerance 5 / +10% Rated voltage V R Rated frequency f R 50 and 60 Hz Output Rated current I R Please read Cautions and warnings and Page 2 of 11

Maximum ratings V max I max I S *Power dissipation * Without discharge resistor V R + 10 % (up to 8 h daily) / V R + 15 % (up to 30 min daily) / V R + 20 % (up to 5 min daily) / V R + 30 % (up to 1 min daily) Up to 1.3 I R (up to 1.5 I R including combined effects of harmonics, overvoltages and capacitance tolerance) Up to 200 I R (A) 0.2 W/kvar (dielectric) and 0.45 W / kvar (total) Test data V TT V TC *tan δ (50 Hz) 1.0 10-3 * Without discharge resistor 2.15 V R during 2 s 3000 V AC / 50 Hz during 10 s Climatic category 40/D T min -40 ºC T max +55 ºC Storage temperature -40 C +85 C T max Hotspot +85 ºC Humidity Av. rel. < 95% Degree of protection Maximum altitude IP00 (optionally IP54 with terminal cover; additional cable gland at cable entry required) 4000 m Mean life expectancy Up to 135000 hours at temperature class -40/C t LD Up to 100000 hours at temperature class -40/D Max. 5000 switchings per year acc. to IEC 60831 Design data Dimensions (d h) Weight approx Impregnation Fixing Max. torque (Al can stud) Mounting position Non PCB, resin filling: soft polyurethane resin Threaded bolt M12 10 Nm Only in the vertical position. See Maintenance and Installation Manual for further details. Please read Cautions and warnings and Page 3 of 11

Terminals Protection degree Maximum terminal current Creepage distance (min) Clearance (min) IP00 for B32300 (optional IP54 with plastic terminal cap, additional cable gland at cable entry required); IP20 for B32301 15 A (fast-on terminals) / 50 A (screw terminals) 12.7 mm 9.6 mm Safety Mechanical safety Max. short circuit current Discharge resistor time Overpressure disconnector (AFC: 10 ka according UL 810 standard) 60 s to 75 V or less Reference standards IEC 60831 1/2, UL 810-5th edition Label design Please read Cautions and warnings and Page 4 of 11

Ordering codes Type 50 Hz 60 Hz C R d h Weight Ordering code Packing Output I unit R Output I R kvar A kvar A µf mm kg pcs Rated voltage 230 V AC, 50/60 Hz, single phase MKD230-I-0.8 0.8 3.5 1.0 4.2 48 63.5 x 64.5 0.3 B32300A2002A830 12 MKD230-I-1.7 1.7 7.4 2.0 8.9 102 63.5 x 102 0.4 B32300A2012A730 12 MKD230-I-2.5 2.5 10.9 3.0 13.1 151 63.5 x 127 0.5 B32300A2022A530 12 Rated voltage 250 V AC, 50/60 Hz, single phase MKD250-I-0.8 0.8 3.2 1.0 3.8 41 50 x 77 0.2 B32300A2002A850 50 MKD250-I-1.7 1.7 6.8 2.0 8.2 87 63.5 x 92 0.4 B32300A2012A750 12 MKD250-I-2.0 2.0 7.8 2.4 9.4 100 63.5 x 92 0.4 B32300A2022A050 12 MKD250-I-2.5 2.5 10.0 3.0 12.0 127 63.5 x 102 0.5 B32300A2022A550 12 MKD250-I-5.0 5.0 20.0 6.0 24.0 255 75 x 166 0.7 B32301A2052#050* 6 MKD250-I-7.5 7.5 30.0 9.0 36.0 382 85 x 196 1.1 B32301A2072#550* 4 MKD250-I-10 10.0 40.0 12.0 48.0 510 85 x 216 1.2 B32301A2102#050* 4 Rated voltage 400 V AC, 50/60 Hz, single phase MKD400-I-0.8 0.8 2.0 1.0 2.4 16 50 x 64.5 0.2 B32300A4002A800 50 MKD400-I-1.7 1.7 4.3 2.0 5.2 34 63.5 x 62.5 0.3 B32300A4012A700 12 MKD400-I-2.5 2.5 6.3 3.0 7.6 50 63.5 x 77 0.3 B32300A4022A500 12 MKD400-I-3.3 3.3 8.3 4.0 10.0 66 63.5 x 102 0.4 B32300A4032A300 12 MKD400-I-4.2 4.2 10.5 5.0 12.6 84 63.5 x 102 0.4 B32300A4051A000 12 MKD400-I-5.0 5.0 12.5 6.0 15.0 100 63.5 x 127 0.5 B32300A4052A000 12 Rated voltage 415 V AC, 50/60 Hz, single phase MKD415-I-0.8 0.8 1.9 1.0 2.3 15 50 x 64.5 0.2 B32300A4082A310 50 MKD415-I-1.7 1.7 4.0 2.0 4.8 31 63.5 x 64.5 0.3 B32300A4012A710 12 MKD415-I-2.5 2.5 6.0 3.0 7.2 46 63.5 x 102 0.4 B32300A4022A510 12 MKD415-I-3.3 3.3 8.0 4.0 9.6 61 63.5 x 102 0.4 B32300A4032A310 12 MKD415-I-5.0 5.0 12.0 6.0 14.4 92 63.5 x 127 0.6 B32300A4052A010 12 Rated voltage 440 V AC, 50/60 Hz, single phase MKD440-I-0.7 0.7 1.6 0.8 1.9 12 50 x 64.5 0.2 B32300A4001A840 50 MKD440-I-1.4 1.4 3.2 1.7 3.8 23 63.5 x 64.5 0.3 B32300A4011A740 12 MKD440-I-2.1 2.1 4.8 2.5 5.8 35 63.5 x 77 0.3 B32300A4021A540 12 MKD440-I-2.8 2.8 6.4 3.4 7.7 46 63.5 x 102 0.4 B32300A4031A340 12 MKD440-I-3.3 3.3 7.5 4.0 9.0 54 63.5 x 102 0.4 B32300A4032A340 12 MKD440-I-4.2 4.2 9.5 5.0 11.4 69 63.5 x 127 0.5 B32300A4051A040 12 MKD440-I-5.0 5.0 11.4 6.0 13.7 82 63.5 x 127 0.5 B32300A4052A040 12 * Available either as B32301A****A*** series (2-terminal design, integrated resistor) or series (4-terminal design, pluggable ceramic resistor). Please replace # with the right character before ordering. Please read Cautions and warnings and Page 5 of 11

Type 50 Hz 60 Hz C R d h Weight Ordering code Packing unit µf mm kg pcs Output kvar I R A Output kvar I R A Rated voltage 480 V AC, 50/60 Hz, single-phase MKD480-I-0.7 0.7 1.5 0.8 1.8 10 50 x 64.5 0.2 B32300A4001A880 50 MKD480-I-1.4 1.4 2.9 1.7 3.5 19 63.5 x 64.5 0.3 B32300A4011A780 12 MKD480-I-2.1 2.1 4.4 2.5 5.3 29 63.5 x 77 0.3 B32300A4021A580 12 MKD480-I-2.8 2.8 5.8 3.4 7.0 39 63.5 x 102 0.4 B32300A4031A380 12 Rated voltage 525 V AC, 50/60 Hz, single-phase MKD525-I-1.4 1.4 2.7 1.7 3.2 16 63.5 x 64.5 0.3 B32300A5011A730 12 MKD525-I-2.8 2.8 5.3 3.4 6.4 32 63.5 x 102 0.4 B32300A5031A320 12 MKD525-I-3.3 3.3 6.3 4.0 7.6 38 63.5 x 102 0.4 B32300A5032A320 12 MKD525-I-4.2 4.2 8.0 5.0 9.6 49 63.5 x 127 0.5 B32300A5051A020 12 MKD525-I-25.0 25.0 47.6 30.0 57.1 289 116 x 200 1.9 B32301A5252#025* 4 * Available either as B32301A****A*** series (2-terminal design, integrated resistor) or series (4-terminal design, pluggable ceramic resistor). Please replace # with the right character before ordering. Important remark Hereafter mentioned capacitors with the wildcard character # are available either with integrated resistors with 2 terminals (B32301*****A*** series) or with pluggable ceramic base discharge resistor with 4 terminals (B32301*****B*** series). The main difference between B32301A****A*** series and series is the way of assembling the discharge resistor. The resistor of B32301A****A*** series is assembled inside of capacitor terminal cover, the ceramic resistor of is plugged into the terminal pin. Please read Cautions and warnings and Page 6 of 11

Dimensional drawings B32300A* B32301A****A*** Please read Cautions and warnings and Page 7 of 11

Cautions and Warnings These figures apply to the capacitor alone. Because the fixing and the terminals may influence the vibration properties, it is necessary to check stability when a capacitor is built in and exposed to vibration. Irrespective of this, you are advised not to locate capacitors where vibration amplitude reaches the maximum in strongly vibrating equipment. Mechanical protection The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided. Grounding The threaded bottom stud of the capacitor has to be used for grounding. In case grounding is done via metal chassis that the capacitor is mounted to, the layer of varnish beneath the washer and nut should be removed. The maximum tightening torque is 10 Nm. Maintenance Check tightness of the connections/terminals periodically. Take current reading twice a year and compare with nominal current. Use a harmonic analyser or true effective RMS-meter. In case of current above the nominal current check your application for modifications. If a significant increase in the amount of non-linear loads has been detected, then a consultant has to be called in for a harmonic study. In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered. Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After 60 seconds the voltage between the terminals must decline to less than 75 V. Check the temperature of capacitors directly after operation for a longer period, but make sure that the capacitors have been switched off. In case of excessive temperature of individual capacitors, it is recommended to replace these capacitors, as this should be an indication for loss factor increase, which is a sign for reaching end of life. Storage and operating conditions Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning especially of the terminals is required to avoid conductive path between phases and/or phases and ground. Note For detailed information about PFC capacitors and cautions, refer to the latest version of EPCOS PFC Product Profile. Please read Cautions and warnings and Page 8 of 11

Display of ordering codes for EPCOS products The ordering code for one and the same EPCOS product can be represented differently in data sheets, data books, other publications, on the EPCOS website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes Please read Cautions and warnings and Page 9 of 11

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association (ZVEI). 7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The IATF certifications confirm our compliance with requirements regarding the quality management system in the automotive industry. Referring to customer requirements and customer specific requirements ( CSR ) TDK always has and will continue to have the policy of respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to emphasize that only requirements mutually agreed upon can and will be implemented in our Quality Management System. For clarification purposes we like to point out that obligations from IATF 16949 shall only become legally binding if individually agreed upon. Page 10 of 11

Important notes 8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Release 2018-06 Page 11 of 11