Technical requirements & conditions for hirers

Similar documents
Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

JERWOOD VANBRUGH THEATRE

Main House Technical Specification

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Matthew Flinders Theatre

Please carefully read this entire form before completing any information.

DEREHAM MEMORIAL HALL

THE ROUNDHOUSE THEATRE

Hopgood Theatre NOARLUNGA CENTRE

ISLAND HALL TECHNICAL INFORMATION

New Theatre Royal Lincoln Technical Information

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

INFORMATION PACK & SCHEDULE OF RATES 2015

Notes for Lighting and Sound Technicians

ROSE THEATRE BASEMENT

The Georgian Theatre Royal Technical Information For Visiting Companies

Information for Incoming Companies

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

ENTERTAINMENT VENUES INVERCARGILL CITY COUNCIL OWNED VENUES, INVERCARGILL, NEW ZEALAND

Theatre Technical Specification

Notes for Lighting and Sound Technicians (A Supplement to Notes for Playing Companies)

Technical Specification Ardhowen Theatre

The Lantern Technical Information

Hirers Technical Information Pack

the CenterStage Policies & Procedures

INFORMATION FOR VISITING COMPANIES

THE MINACK THEATRE. Notes for Playing Companies. Please note 2016 amendment to Section 5 - Public Liability & Employer Liability Insurance

Pleasance London Main House Visiting Company Information Pack May 2017

Hopgood Theatre NOARLUNGA CENTRE

TECHNICAL REQUIREMENT FORM

TECHNICAL INFORMATION

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

USE OF JOHN M. GREENE HALL

Scale of Hire Charges

CONTENTS GENERAL INFORMATION AND CONDITIONS OF HIRE

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

The Standard Bank Studio is a music venue made from the choir stalls and the stage of the Cape Town City Hall Auditorium. It

The Mannie Manim Technical Specifications

Technical Information

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Queensland Performing Arts Centre

Technical Information

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Barney Simon Theatre Technical Specifications

Please note we do have some regular volunteer technicians but there is no full time technical manager.

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Phoenix Theatre Elwood

Technical Specifications Updated 01/10/2017. Stage

WHO WE ARE As a home is not just a house, a Theatre is not just a space.

Matt Dann Cultural Centre

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

The Haymarket Basingstoke Technical Specifications

ARTISTIC RENTALS RATE CARD. Royal Festival Hall AUDITORIUM CAPACITIES ARTISTIC HIRE RATES

ROSE THEATRE MAIN THEATRE

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Technical Pack. Attenborough Arts Centre

National Folk Festival PA Specs 2018 MARQUEE

CENTRE FOR PERFORMING ARTS

WHO WE ARE As a home is not just a house, a Theatre is not just a space.

Technical Specifications

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

SECREST AUDITORIUM TECHNICAL PACKAGE

2012 HSC Entertainment Industry Sample Answers

Cromer Road Holt Norfolk NR25 6EA

Darlington Hippodrome Technical Specification

Dr JOHN GALLAGHER CONCERT CHAMBER

Theatre Technical Specifications

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Compass Theatre - Technical Information Pack

Technical Specification

Lancaster Performing Arts Center RENTAL FEES and Policies

TOURING RIDER Where Magic & Motion Meet!

TERMS AND CONDITIONS FOR RENTAL OF THE EARL CAMERON THEATRE AND CITY HALL FOYER. Please Read Entire Document Prior To Signing

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

APPENDIX J Richmond High School Performing Arts Theater Usage Policy (December 2018)

DANCE BASE TECHNICAL SPECIFICATION

Rider Part1: Technical Requirements, A Cappella Show

GENERAL INFORMATION FOR HIRERS

PSYCHIC SALLY PRODUCTION RIDER & FOH REQUESTS (UPDATED 2016)

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Theatre Royal Pre-Production Requirements

Technical Specifications

MAJESTIC (Circus Tent)

HOUSE / TECHNICAL / FESTIVAL RULES

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

Where performance matters

The Elbert Theatre Rental Application Packet

Summary. Access and Parking

TECHNICAL SPECIFICATIONS

WHO WE ARE As a home is not just a house, a Theatre is not just a space.

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Stage. Get In & Parking

Technical Specification

Concert Hall Technical Specifications

ARTISTIC RENTALS RATE CARD. Queen Elizabeth Hall AUDITORIUM CAPACITIES ARTISTIC HIRE RATES

BRAMALL INTRODUCING THE. Venue hire for classical & pop music, spoken word & comedy

Shouson Theatre Venue Specifications (updated Jan 2017)

Transcription:

Technical requirements & conditions for hirers This form is designed as the basis for a pre-production meeting between the Stage Manager/Hirer and the Mechanics Technical Manager at which production details for the show will be discussed. Please read carefully and complete all areas of the following document. To arrange the meeting please contact Lee Rothwell on 01282 477180 or Lrothwell@burnley.gov.uk at your earliest convenience. The Mechanics Technical Manager and the hirer should sign this form when both parties are agreed on the out come of the production meeting. Please note: If this meeting does not take place at least five weeks prior to the performance, we may not be able to supply your specifications. 1. Portable Appliance Testing All Electrical equipment brought into the Mechanics must be P.A.T tested and accompanied by a valid Test Certificate; otherwise you will not be permitted to use it. This test cannot be carried out at the Mechanics 2. Scenery/back drops. All scenery/ backdrops & set brought into the Mechanics must be made up of fire retardant material or be fire proofed. Proof of compliance with the above will be required. 3. Access to the Building Time of access to the building for get-ins, rehearsals and performances must be stated clearly at the meeting. Please be very clear as to when you require access to the Theatre, as staff rotas are compiled from the information you give and you will be charged accordingly. Access to the building on Get-In & rehearsal nights is via the top Manchester Road entrance only and it is the responsibility of the hirer to sign in & out Performers and Crew at this point as the door is locked shut and unmanned. 4. Heath & Safety Engineers and SM s or DSM s, must be electrically competent, have a proven working knowledge of Lighting & Sound Consoles, Hemps and Erecting Scenery. If competence cannot be proven to the Technical /Stage Manager they will not permit the equipment to be used. The roof space above the auditorium [Lighting Gantries FOH 1-3] is a Permit To Work Area and only persons with a Working At Heights Certificate will be permitted to work in this area. This should be discussed with your Lighting Technician, Designer or Tour Manager to consider the implications. There will be one member of the Mechanics technical team on duty each session in a supervisory and advisory capacity only 5.The Get-Out Must take place straight after your last Performance. The stage, control room and dressing rooms must be left tidy and all equipment returned back to storage. The Hirer s responsible representative, should notify the Mechanics Duty Technician when get-out has been completed. 6. Early Delivery & Late Collection Scenery, Props etc, is the responsibility of the hirer/society a representative must be in attendance to receive and dispatch the goods especially if the goods need to be signed for. Temporary storage of scenery, props or costumes can be arranged at the production meeting but could incur an additional charge. The Mechanics will not be held responsible for any equipment temporally stored by your Society or Company.

Show / Event Details Name of Society / Company Name of Show / Event Stage Manager / Hirer Contact Details Name: Address: Telephone: E-mail address: Post Code: Mobile: It is the Stage Manager & Hirers ultimate responsibility to ensure that: All hiring terms and conditions are carried out correctly. Health and Safety regulations and procedures are adhered to. All production details agreed on this form are met and understood. All the Theatre, Lighting and Sound equipment is looked after and restored back to the Mechanics standard rig Formats on the Get-Out and any additional equipment is returned back to storage. Access Dates: Performance Dates From: / / To: / / Early Delivery if any: Date: Time: Technical Rehearsal Date: Time: from: to: FULL DRESS REHEARSAL: Date: Time: from: to: Get-Out: Must take place straight after the last Performance. Late Collection: Date: Time: A representative of the hirer/society must be present to return goods especially if they have to be signed for. Access & Performance Times Performance nights only Time access required to Dressing Rooms and Stage Areas Under normal circumstances this would be1hr prior to doors Start Time: Approx Interval Time: Approx Finish Time:

Lighting The following is supplied as standard: 120 way ETC Sensor Dimmers controlled by 1 x Chamsys Magicq 100. Which of the following facilities do you require? Do you require the Mechanics Basic Theatre Lighting Rig: YES NO This made up of 30 x 1kw PC s & 8 x 1kw Profiles & 10 x 650wt 16/30 profiles. OR Do you require the Mechanics Basic Music Lighting Rig: YES NO This made up of 40 x 1kw Par 64 s & 8 x ACL s. Do you require the Mechanics Follow spots? YES NO How many? (Max. 2 x 1.2kw [MSR] spots available) * Do you require the services of the Mechanics Lighting Engineer? YES NO to Rig, De-Rig, Focus and Programme the lighting console * Do you require the services of the Mechanics Follow Spots Operators? YES NO *These services are not included in the hire fee. All extra costs can be supplied on request. Additional Lighting Equipment is available for hire. Please ask for information and hire charges. Are you using any of your own Lighting System or Generics? YES NO Notes Visiting Lighting Engineer / Designer Contact Details. Name: Telephone: E-mail address: Mobile: The Lighting Engineer must be electrically competent and have a proven working knowledge of lighting systems. Should competence not be proven to the Resident Stage Manager they will not be permitted to use the equipment. All electrical equipment hired or belonging to the Hirer and brought onto the Mechanics premises requires a fully valid PAT Test Certificate otherwise you will not be permitted to use it under any circumstances. It is the sole responsibly of the Lighting Engineer to return ALL Lanterns, TRS, Gels and Extra back to storage during the Get-Out, which will commence straight after the last performance. The Front of house Lighting Grid is a Permit To Work area only persons with a valid Working At Heights Certificate will be allowed access to this area.

PA System Do you require the Mechanics 3kw PA System YES NO We can supply the following: Allen & Health GL2400 32 Channel Desk, 2 x CD player, 1X MD Player AND Lexicon & TC Electronic FX Unit, Kling & Freitag cabinets, which are made up of 2 x 12 Horn x 400wt & 4 x 6 Horn 165wt cabinets which include 2 delays all powered by Amcron amps. 2 X on stage monitors, 2 X Mics with XLR leads are supplied with the system. Other equipment is available for hire. Please call for more information and hire charges. Are you using you own PA system? YES NO If you re mixing position is to be located in the auditorium with theatre seating format, rows F & G 12 15 must be removed from sale to accommodate the sound console and racks. A 63amp single-phase clean power supply is located Stage Left on stage. If yes please specify below what you will intend to bring with you Notes Visiting Sound Engineer Contact Details. Name: Telephone: E-mail address: Mobile: The Sound Engineer when using In-House equipment must be electrically competent and have a proven working knowledge of sound systems. If competence cannot be proven to the Resident Stage Manager they will not be permitted to use the equipment. All electrical equipment hired or belonging to the Hirer and brought onto the Mechanics premises requires a fully valid PAT Test Certificate otherwise you will not be permitted to use it under any circumstances. It is the sole responsibly of the Visiting Sound Engineer to Re-set the Desk and return all Mic Cables, Mics, Stands and Extra back to storage Mics during the Get-Out, which will commence straight after the last performance.

Stage Facilities & Details. Stage Management / Prompt Side: location stage left there is communication between Control Room, Stage and Opposite Prompt, via com s, a show relay to dressing rooms and call facilities to Dressing Rooms and FOH. A TV Monitor is located prompt side and in the dressing room foyer relaying vision from the stage. The Proscenium is 27ft 10 [8.5Mtrs] wide and the Height 13ft 9 [4.2Mtrs]. The stage is 23ft 6 [7.15Mtrs] deep the clearance height on stage with lanterns hung and trusses on limit is 16ft 4 [5Mtrs] Height to grid is 16ft 2 (4.9Mtrs]. Stage Power is located prompt side, stage left and consists of a 32, 63 & 125amp Single and 3 Phase Supplies, there is a 63amp Clean Supply for sound use only. Flying Facilities are all hemp bars. Stage Curtains are operated from Prompt corner or control room they are variable speed and on the fastest speed take 7 seconds to open or close. Safety Curtain is operated from Prompt side stage left. Do you require a Stage Extension? YES NO A row of auditorium seating will be removed when using the forestage 4ft (1.2Mtrs). A minimum gap of 1.2 metres (4 ft) must be maintained between the front of the stage extension and the front row of the auditorium seating to comply with Health and Safety requirements and must never be less than this at any time. Special Effects 1. Pyrotechnics YES NO 2. Smoke Machine YES NO 3. Haze Machine YES NO 4. Strobes YES NO The use of strobe(s) requires you to inform the audience in advance before you use them. 5. Firearms / Weapons (Guns, Swords & Knifes) YES NO BLANK FIRING ONLY & BLUNT Licensing require the item to be locked away securely when not in use. 6. Naked Flame YES 7. Smoking on stage YES NO Please note: 1, 2 and 3 will incur a hire charge when supplied by Mechanics. 5 may need Police Clearance. Written permission from Environmental Health and /or Fire Brigade must be obtained before using certain pyrotechnic devices, firearms and naked flames and will require 4 5 weeks minimum notice to receive permission. 1, 4, 5, 6 & 7 are subject to Health & Safety approval and a Full Risk Assessment. Failure to complete the above section may result in permission not being granted

Rostra Metal Multi Height Rostra 8ft x 6ft YES NO How many? Heights are 2 6 /3 /3 6 /4 [0.75/0.9/1.05/1.2mtrs] (4 available) Wooden Rostra 3ft 3 x 6ft 7 [1mtr x 2mrts] (8 available) YES NO How many? Height 2ft 6 [0.75mtr] Metal Rostra 8ft x 4ft [2.4Mtrs x 1.2Mtrs] YES NO How many? Heights are 4, 1ft & 2ft [0.01/0.03/0.06mtrs](4 available) Orchestra Do you require an Orchestra Pit? YES NO Music Stands YES NO How many? (Max. 12 available) Conductor s Stand YES NO (1 available) A Row in the auditorium will be removed if you require a 6ft deep Orchestra pit. If you require both Stage Extension & orchestra pit rows A, B & C will be removed. Piano Grand Piano (C) YES NO (This piano cannot be removed from the stage) Steinway Upright YES NO Will you require the pianos to be tuned? YES NO If so to what pitch? Only the Mechanics authorised tuner may carry out piano tuning. Phone number available on request.

Dressing Room Facilities 5 x dressing rooms, one with disabled access. Dressing Rooms are located on the next level up from the stage via a staircase. A TV Monitor is located in the dressing room foyer relaying vision from the stage. If you require accommodation for over 30 cast members you must book the Tudor room. Dressing rooms will be locked 20mins after performance comes down Under stage area cannot be used as a dressing room Do you require dressing room facilities? YES NO Notes and Details of any other requirements Availability of items requested on this form are not guaranteed until the form has been signed and approved by the Mechanics Technical Manager Hirer Signed by: Position: Print name: Mechanics Technical Team Signed by: Position: Date: This document must be completed in full and signed by both Hirer and the Mechanics Technical Manager no less than six weeks prior to your event so that we can do event. This will enable us to ensure that your event is a success. If you require assistance please call Lee Rothwell on 01282 477180 or E-mail Lrothwell@burnley.gov.uk