THE REPUBLIC CULTURAL CENTRE TECHNICAL FACILITIES (STUDIO)

Similar documents
Technical Specification (Drama Theatre)

Technical Specification (Studio Theatre)

Technical Specification (Studio Theatre)

Technical Specification (Drama Theatre)

Theatre Technical Specifications

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Data Sheet

CENTRE FOR PERFORMING ARTS

Technical Specification Pavilion Dance

2017 TECHNICAL SPECIFICATIONS

Technical Services and Specification

Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Downtown Arts Center Tech Packet. General Information

Matt Dann Cultural Centre

RPAC REDLANDS PERFORMING ARTS CENTRE

Powerhouse Theatre technical information and general specifications 2017

TECHNICAL SPECIFICATIONS

HIRE AND TECHNICAL INFORMATION

Theatre Technical Specifications

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Specification

Technical Specification Ardhowen Theatre

Technical Specifications (Concert Hall)

TECHNICAL SPECIFICATIONS

Main House Technical Specifications

Theatre Technical Specification

DEREHAM MEMORIAL HALL

Technical Specification for the Alley Theatre, Strabane

THE STREET THEATRE. Technical Specifications

Technical Specifications Updated 01/10/2017. Stage

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Shouson Theatre Venue Specifications (updated Jan 2017)

Main House Technical Specification

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Stage. Get In & Parking

Technical Specifications

Jane Mallet Theatre Technical Specifications

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Technical Pack. Attenborough Arts Centre

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

BLACK BOX 7 /1/ 15. Technical Information TABLE OF CONTENTS STAGING. Page. 2 Loading Area Stage Specifications 3 Rigging Specifications Accessories

Technical Director of Production Andrew Quick Ext 252

Technical Specification. Updated: April 2016

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Dr JOHN GALLAGHER CONCERT CHAMBER

SHUBERT THEATER 247 College Street, New Haven, CT

The Anvil Technical Specifications

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Access to back stage is off Fletcher St on the eastern side of the building

Technical Information

Dale F. Halton Theater Technical Specifications

There are 10 dressing rooms in Theatre Kerkrade.

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Mics, DIs, Stands, and Cables

Auditorium: 16m x 24m (including stage area) Variable acoustics to suit different performance types

Technical Specifications and Inventory Spring 2018

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Information

350 fixed seats with the capabilities of an additional 50 removable seats.

Sandusky State Theatre Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Hopgood Theatre NOARLUNGA CENTRE

Technical Specifications. Taylor Little Theater

Louis Koo Cinema Venue Specifications (updated 2018)

CHELSEA THEATRE. Technical Specifications

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Visy Theatre technical information and general specifications 2019

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

THEATRE EQUIPMENT DECEMBER 2017

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Barney Simon Theatre Technical Specifications

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Dinkelspiel Auditorium - Technical Specifications

JERWOOD VANBRUGH THEATRE

Technical Specification

Technical Specifications

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

AKI STUDIO THEATRE Information and Technical Specifications

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Summary. Access and Parking

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Marjorie S. Deane Little Theater

Main Stage Technical Specs - Hall #2

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

ROSE THEATRE BASEMENT

The Breen Center for the Performing Arts Saint Ignatius High School

MONASH University Academy of Performing Arts

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

The Haymarket Basingstoke Technical Specifications

Technical Specification

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Transcription:

STUDIO STUDIO SEATING CAPACITY: 346 (maximum) Stalls (Level 2) fixed seats 235 retractable seats 111 Total: 346 Wheelchair Space available in front of Row A Control for Sound is situated at the audience cockpit Control for Communications and Video are situated at the backstage Control Rooms for Lighting situated on Level 3 Refer to Studio Seating Plan for details STUDIO ACOUSTICS Reverberation Time is between 1.0 1.6 seconds (unoccupied) and 1.0 1.3 seconds (occupied). Noise Criterion (NC) is 25. LOADING/UNLOADING (shared with THEATRE and LAB) Access from street level via Woodlands Drive 91 / Republic Crescent to the TRCC Loading Bay. Dock Leveller is provided measuring 1.80mm x 2.50mm x 0.85m (dock height) Loading Bay driveway entrance clearance height 4.50m Loading Bay to loading platform roller shutter W 5.40m x H 4.50m Loading Door to Stage W 3.00m x H 4.00m Cargo Lift (max. 3000kg) for access to Level 2 and Level 3 facilities Cargo Lift dimensions W 3.00m x D 2.20m x H 2.70m. STAGE FACILITIES Flying Systems Comprises a combination of: a) 2 sets motorised flying Linesets for lighting fixtures at 1.6m apart, each measuring L 9.00m x 50mm H pipes with a spread load of 500kg b) 1 set motorised Projection Screen 5m (W) x 3m (H) fixed position at the rear stage All Flying battens & bars are fixed and cannot be changed.

STAGE SPECIFICATIONS Semi-circular maple timber sprung flooring of the following dimensions: Flat Floor Stage Opening Measurement in metres Width (DS) 17.63 Width (US) 7.13 Edge of stage to rear wall 6.28 Edge of stage to projection screen 5.98 Edge of bleacher to rear wall (retracted) 13.36 Edge of bleacher to projection screen (retracted) 13.06 Height stage level to tip of: Ceiling (sloped) 10 ~ 11.20 Refer to Studio Stage Plan for details Rigging Access Equipment 01 x Genie AWP-25S Aerial Work Platform (9.6m working height, platform height 7.6m) Operator must have valid MEWP certification Portable Ladders will be available

LIGHTING SYSTEM Console Zero88 ORB Lighting Console c/w 2048 Control Channels, fully patchable to 4 DMX Universes. Output via 5 Pin XLR and Ethernet Racks and Dimmers 01 x 72 Channel Rack, dual CEM complete with 24 dual 5kw dimmer modules, 4 dual 5kw Relays and 2 dual 5kw non-dim modules for UPS, each equipped with individual RCD protection. All lighting receptacles are 16A CEE17 throughout House Light System 5 stage dimming module for in-house ceiling lighting Additional Power 08 x Floor CCTI 16A, and domestic 3-pin 13A 240V switched socket outlets are available at various locations on and around stage area. Approval from TRCC management must be sought before any of hirer s own electrical equipment is attached to, or used in conjunction with TRCC s own electrical fittings. *note: Singapore power is 400 volts 3 phase, and 230 volts single phase 50 Hz.

LIGHTING INVENTORY Studio House Rig (*subject to additional rental charges): FOH: FOH: (W) Qty 19 ETC Source 4 Profile Spot 750W 07 14 ETC Source 4 Profile Spot 750W 08 Overhead: (W) Qty ETC Source 4 Parnel 750W 24 50 ETC Source 4 Profile Spot 750W 08 *Martin MAC700 Wash Moving Lights 700W 04 *Martin MAC700 Spot Moving Lights 700W 04 Side Booms (1 pair): 26 ETC Source 4 Profile Spot 750W 04 PAR64 Parcans 1000W 12 Additional Lighting Inventory (*subject to additional rental charges): Consoles *Avolites Pearl 2008 Lighting Console - 01 *Avolites Pearl Tiger Lighting Console - 01 *Avolites Tiger Touch Lighting Console - 01 Fixtures *Robert Juliat Super Korrigan HMI Followspot 1200W 02 *Varilite VL3000Q Moving Lights 1200W 10 *Clay Paky Alpha 300 Beam Moving Lights 300W 10 ETC Source 4 Parnel 750W 50 ETC Source 4 Profile Spot 750W 40 Misc Accessories ETC Source 4 Parnel Top Hat - ETC Source 4 Profile Spot Drop-in Iris - ETC Source 4 Gobo Holder B Size - 60 B Size Standard Gobos Martin JEM Hazer Pro Martin JEM ZR-35 Fog Machine - - - 02 02

SOUND SYSTEM House Console Yamaha M7CL-48 Digital Live Sound Mixing Console comes with FOH & Stage Racks for 48 channel inputs & 16 channel outputs, on-board EQ, dynamics and complete suite of DSP plug-ins. Sound Reinforcement Systems ITEM QTY Main Left & Right Loudspeaker System CODA Audio Ultra Compact Line Array System, per cluster consist of: CODA Audio LA4A dual 5 with 4 waveguide CODA Audio LA4 15 subwoofer 04 02 Fixed and Stage Portable Foldback and Monitors Loudspeakers NEXO PS10/PS15 Loudspeakers Power Amplifiers to power the Loudspeakers System CODA Audio DSC260N DSP Controller Camco Vortex 6 Power Amplifiers Yamaha Power Amplifiers Model PC 9500N and PC4800N with NEXO controllers Playback Equipment Denon DND-6000 Dual CD Player Tascam CD-RW 2000 CD Recorder 01 01 Wireless Microphones Installed (*subject to additional rental charges): ITEM TYPE QTY Shure UHF-R Wireless Set* Handheld (Beta87A) or Headset (WBH53) 04 (first 4 pieces are free of charge) Wired Microphones (subject to additional rental charges) An assortment of microphones - Shure, AKG, Neumann, Sennheiser, etc. and direct injection (DI) boxes are also available. Refer to additional Equipment Rental Rates

COMMUNICATIONS SYSTEM ClearCom MS-812A Analog Partyline Production Intercom with connection to Sound Control, Lighting Control, Follow-spots, FOH Gallery, Stage Left & Right and other technical locations. Stage Manager s Desk A Stage Manager s work desk is available backstage Production Desk (Director s) A portable Director s work desk is available. Production Communications System Clear-Com MS-812A Analog Partyline Production Intercom Master Station (Wired) Headsets and Beltpacks Clear-Com RS-602 dual channel wired beltpack comes with single muff headset Paging System Yamaha Programmable Paging System for backstage, dressing rooms & all operation areas, corridors, passages ways, etc. Audio Show Relay Sound from the performance is routed to dressing rooms, passages, etc. Foyers Chime To alert patrons that it is about time to open the performance, amplified chimes signals are relayed to the loudspeakers in the foyers before the opening and intermission. Late-Comers Video Show Relay For late-comers, live video and audio signals are relayed to 42 LCD TV located at the stall and circle foyers. Production CCTV To assist production, Panasonic colour cum infrared (night-vision) cameras are used to capture the production and relay the signals to 7 LCD at the Director s desk and various technical locations with 15 LCD TV.

PROJECTION SYSTEM (subject to additional rental charges) Front Projection Panasonic PT-DS100X 3 Chip DLP Projector with ET-D75LE30 / 2.6 5.1 Long-Throw Zoom lens & complete with A/V Switcher, Converter, Audio Monitors and LCD VDUs. 01 set of Motorised Front Projection Screen complete with frame, Dimension 5m (W) x 3.2m (H) Playback Decks 01 x Pioneer DVD Player 02 x VGA (15-pin D-Sub) for Computer 01 x RGBHV (5-BNC) for Video Devices 01 x HDMI for Computer and Media Players ADDITIONAL EQUIPMENT (*subject to additional rental charges) Item Description *Stage Risers with skirting (black) - 8 ft (W) x 4 ft (D) x 16 or 24 (H) adjustable Republic Polytechnic Rostrum Qty 24 02 *Wenger Orchestra Chair 80 *Wenger Music Stand *Wenger High Stool *Dance Mat (Black) *Grand Piano - Kawai SK7 *Baby Grand Piano - Yamaha DC2A with Disklavier *Upright Piano - Yamaha U5 80 5 1 set 1 1 1

DRESSING ROOMS Dressing rooms fitted with paging loudspeaker, dressing full length and table with mirrors lights, washbasins, costume racks and pin boards. Level 2 Ladies and Gents Toilets with hot/cold showers 2 Group Dressing Rooms for 5 8pax 2 Dressing Rooms for 2 4pax 1 Handicap Toilet 1 Green Room with attached Pantry Other Supporting Facilities (subject to additional rental charges) 1 VIP Reception Room 1 VIP Holding Room 6 Practice Rooms 1 Art Studio 1 Conference Room 2 Dance Studio Note: All inventory subject to availability. Kindly contact TRCC Production Department for additional information. Full list of additional equipment available upon request. In our efforts to serve you better, we would like to have your production requirements at the earliest possible time, preferably two weeks before your presentation. They are important to us as we would like to make it happen. Otherwise, depending on the availability of facilities, we will allot our usual basic to cater for your needs. The above information is correct as of 5 June 2018 and is subject to changes without prior notice.