1 7008 Multi-channel Long Memory Digital Oscilloscope VIEW RECORDERS (70088) 6 5mm 7kg (6-3/ 8-3/ 6-3/" 37.5 lbs) Safety Standards; EN600 EMI Standard; EN550 Group Class A Immunity Standard; EN5008-: 995 The digital oscilloscope, with a maximum record length of 6 MW, features more than just a long record length. We designed this instrument to facilitate long record measurement work. This digital oscilloscope can efficiently capture abnormal phenomena buried in long data, allowing you to search for and analyze the causes of these abnormal phenomena. We made the record length per channel as long as possible to enable you to carry out efficient troubleshooting. We also designed the instrument to measure data in at least six channels, enabling you to determine the cause and effect relationship between each signal. The instrument also has excellent zoom operability to permit analysis of captured waveforms. Select the number of channels and record length suitable for your application. After the purchase, if you need more channels or a larger record length, your oscilloscope can be upgraded. SELECTION GUIDE Model Number of input channels Max Sampling rate Per channel 00 MS/s 00 MS/s 00 MS/s 00 MS/s 00 MS/s 00 MS/s 00 MS/s 00 MS/s 00 MS/s 00 MS/s 00 MS/s 00 MS/s Max M words M words M words M words FEATURES Max 8 analog inputs or analog inputs +3 bit digital inputs (optional) You can simultaneously observe signals from a maximum of 8 channels. Each channel is provided with a 00 MS/s A/D converter. Max 6M words By limiting the number of channels used to half the number of channels incorporated in the instrument, you can increase the maximum record length of per channel up to 6 M words. Dual zoom display The instrument supports a dual zoom display function which simultaneously displays the entire captured waveform together with two selected parts of the same waveform. History memory The history memory, which holds up to 8000 screens, can assist you in troubleshooting by letting you recall previous displays. Logic inputs (optional) logic probe offers 8 bit logic inputs in exchange for analog input. The feature provides mixed analog and digital signal observation. In its maximum configuration, the offers ch analog and 3 bit digital signal observation. Built-in 3.5 inch FDD Built-in MO drive (optional) Built-in printer (optional) FUNCTIONS EFFECTIVE UTILIZATION OF THE LONG MEMORY A long memory is useful not only for capturing single shot signals. The long memory of the can meet a variety of measurement needs. High Time Resolution Measurement Using the Long Memory When you need to capture fast noise and surge signals using a slow time/div range, a long record length is necessary. For instance, at 0 µs/div several tens of Kwords may be required. The MW record length of the supports a sampling rate of Record length Per channel M words M words M words M words Frequency band Number of channels that can be used at the max sampling rate or max record length 3 3 3
2 even when you are monitoring waveforms of several milliseconds. When you are observing transient phenomena or electronically controlled machine signals, the signals captured by the long memory are displayed on the screen in the correct orientation. Capturing Signals Using a Divided Long Memory History Memory Holds up to 8000 Past Images Troubleshooting of a designed circuit starts from capturing of an abnormal signal. Often, when you wish to capture an abnormal phenomenon, you do not know the correct trigger conditions for capturing the signal. You may be lucky enough to display the abnormal phenomenon on the screen by monitoring the signal for some time using simple trigger conditions. However, when you use a normal digital oscilloscope, an abnormal signal that appears momentarily is updated by the next signal. The history memory holds up to 8000 previous displays without any need for special settings. An abnormal phenomenon that appeared for only an instant can be recalled later. Example of a superimposed display of captured past screens Sequential Store Function with A Dead Time of 0 µs Normally, when a waveform is displayed on a digital oscilloscope in realtime, a dead time of several ms occurs. Consequently, you cannot use a normal digital oscilloscope for applications requiring acquisition of all the signals generated at intervals of ms or less. The sequential store function of the eliminates the process of displaying the acquired signals, thus enabling the signals to be captured with only a short dead time. Like the history memory function, the sequential store function enables signals that satisfy the trigger conditions for up to 8000 measurements to be acquired by the built-in memory. Difference between The History Memory Function and The Sequential Store Function Both the history memory function and the sequential store function use the memory divided into several blocks rather than as a single unit. The history memory function uses the divided memory blocks as a ring memory, and the contents of the oldest memory block are updated until the stop key is pressed. The sequential store function does not update the contents of the memory after acquiring the specified number of waveforms. As indicated in the figure below, when the sequential store function is used, signals are not displayed each time they are acquired into memory. History memory function: Effective for capturing abnormal signals whose nature is not known. Sequential store function: Effective for capturing signals generated at a rate of no more than several ms, without omission. Wave form display with sequential store-function Time Memory block of number of designations SIMPLE, VERSATILE ZOOM A zoom function that magnifies part of the captured signal is an important feature of a digital oscilloscope that has a long memory. The enables you to make various kinds of zoom displays by means of simple operations. Zoom that Can Simultaneously Display Traces with Intuitive Operations The zoom operation of the is the same as the popular zoom operation used in the DL50/D50L and DL000 series. The ASIC developed by YOKOGAWA processes the long memory at high speed, enabling you to display the desired area instantaneously. Various Zoom Displays The overall screen of a signal captured by the is defined as Main, and an enlarged screen of part of the waveform is defined as Zoom. You can set two enlarged areas Zoom (Z) and Zoom (Z) with respect to a captured waveform. You can combine the Main screen, the Z screen and the Z screen into a single screen. In the Main&Z&Z setting mode which simultaneously displays the Main screen and the two enlarged screens, Z and Z, a maximum of analog signals can be displayed simultaneously. Main display Main & Z & Z display By Using The Zoom Allocation Function, You Can Display An Enlarged Form of One or More of A Number of Waveforms on A Screen. When performing multi-channel measurements, if it is not necessary to enlarge all of the waveforms. You can use the zoom allocation function to display only certain selected waveforms in the Zoom screen in enlarged form. Wave form display with history memory function Time Memory (n) Memory (n+) When the zoom allocation function is not used When the zoom allocation function is used
3 VIEW RECORDERS YOU CAN SELECT A SIGNAL CAPTURING METHOD AND A DISPLAY METHOD THAT IS SUITABLE FOR THE PARTICULAR MEASUREMENT YOU WISH TO PERFORM. Envelope If you perform signal observation for at least several seconds, you cannot capture signals at the maximum sampling rate, even if you use a long memory of 6M words. However, by using the envelope mode of the, you can always store the peak value of the signal at a sampling rate of 00 MS/s, regardless of the Time/div setting. also be set using voltage values. You can use the measure save function. (which arranges the results of the past 5 measurements up to the point where signal acquisition stopped) to output these results in ASCII format. You can process these results using spreadsheet calculation software. Example of automatic measurement of waveform parameter When envelope is ON When envelope is OFF Box Average The resolution of the A/D converter of the is 8 bits. By using the box average function, you can capture signals at an equivalent resolution of up to bits depending upon the Time/ div setting. The box average function is also effective for capturing single shot signals. When box average is ON (After the signal is captured, zoom takes place in the voltage axis direction) When box average is OFF (After the signal is captured, zoom takes place in the voltage axis direction) Roll Mode Display The roll mode displays a low speed signal on the screen in such a way that it rolls, thus enabling it to be recorded on a pen recorder. This mode can also be used in combination with the envelope to capture surge signals of several tens of MHz, or in combination with the box average function to capture signals at high resolution. Histogram Analysis Wave statistical processing This function specifies the voltage and the time range. After a signal has been acquired a number of times, the frequency of occurrence of time values and voltage values are displayed. This is effective for analyzing jitter, for example. Statistical processing of the waveform parameter results The measurement results for the set number of acquisitions of the specified items of the waveform parameters are displayed in the form of a histogram. Voltage histogram display By displaying a histogram of voltage for each acquisition, you can analyze the waveform from a different angle. Waveform Calculation Software [User Define is An Option] The supports basic functions which performs addition, subtraction, multiplication and division phase performs a phase shift followed by before mentioned computations. Binary converts an analog signal into a bit patterns of ones and zeros, based on a defined threshold. User define math function (optional) enables you to combine various funtions to perform waveform calculation. Waveform display when the roll mode is used Example of roll mode display HIGH-SPEED PRIMARY PROCESSING OF CAPTURED SIGNALS The i960 Intel RISC processor installed in the automatically measures the waveform parameters, and also performs waveform calculations and other data processing, at high speed. Automatic Measurement of Waveform Parameters You can select various items such as amplitude, rise, and interchannel delay, from a total of items, for each channel. The reference values of the parameters related to the time axis can Example of a user define of the
4 The user define math function offers functions such as square root, exponential, common logarithms, differentiation, and integration, pulse-width, Hilbert transform, and FFT. These calculations are all performed in the Math and Math areas and you can also use calculation results from Math in Math functions. By combining these functions, you can perform calculations such as demodulation of FM modulated waveforms. Linear Scaling Function Converts Voltages into Physical Values. When recording an output from a sensor, for example, it is desirable to convert it directly into a physical value such as rpm or m/s rather than leaving it as a voltage. The linear scaling function of the assigns coefficients and offset values to enable the input voltage to be converted into a physical value. In addition, a unit can be attached to a converted result, enabling it to be displayed directly as a physical value. YOU CAN OUTPUT A CAPTURED WAVEFORM IN VARIOUS FORMS DEPENDING ON THE PARTICULAR APPLICATION. Outputting A Signal to The Built-in Printer (option) There are two ways you can output a signal to the built-in printer. The short copy format in which the screen data is printed and the long copy format in which signal data in the acquisition memory is printed out in an expanded form. Example of short copy Example of long copy TRIGGERS THAT ARE SUPPORTED BY THE Trigger functions for ease of operation Select one of two trigger settings, SIMPLE which is related to edge trigger settings, and ENHANCED which is related to other settings, according to your particular application. SIMPLE Settings related to the edge trigger Edge trigger Gate trigger A trigger is generated when the selected waveform crosses a set level. A vertial gate is placed ahead of the trigger point. A trigger occurs when the trigger conditions are met after the signal meets the gate condition(pass or bypass) A B (n) A Delay B Edge On A The trigger condition is satisfied when the B trigger occurs n times after the A trigger condition is met. The trigger condition is satisfied when the B trigger conditions are met after the A trigger occures and the set delay time has elapsed. The trigger occurs at the point in time at which the edge of a selected input channel is detected while the A pattern trigger condition exists. OR The trigger occurs when any one of the individual channnel edge triggers occur. ENHANCED Settings not related to the edge trigger B > Time B < Time A trigger is generated on the falling or rising edge of a pulse when the pulse width exceeds the preset time. The setable range is 90ns to 5s. A trigger is generated on the falling or rising edge of a pulse when the pulse width is less than the preset time. The minimum glitch detection is 5ns. B Time Out A trigger occurs when the B trigger condition remains true for the set period of time. TV Window Logic A trigger is generated by a video signal such as NTSC, PAL, HDTV, etc. A trigger occurs when the signal crosses the upper or lower defined levels. A trigger is defined by combination of the logic inputs.
5 VIEW RECORDERS Output to A Personal Computer Data can be transferred on-line via GP-IB, and also transferred off-line by using an FD or MO disk (a built-in MO drive is available as an option). Saving a hard copy image (image file) You can insert hard copy images saved in the in an image format, such as TIFF or BMP, directly into text made with a word processor. This enables you to efficiently create reports and papers using a word processor. You can save hard copy images not only in black and white but also in color or a gray scale. SPECIFICATIONS Vertical section Number of input channels:,, 6, 8 (Differs depending upon the model) Vertical resolution: 8 bits (in normal mode) Max bit (after average or box average processing) Max sampling rate: Normal (interleave mode) 00 MS/s (all channels simultaneously) Equivalent time 50 GS/s Frequency band (-3 db): DC to Voltage axis sensitivity: mv/div * to 5 V/div DC accuracy * : ±(.5% of 8 div + offset voltage accuracy) *5 Offset voltage accuracy: to 50 mv/div ±(% of set value + 0. mv) 00 to 500 mv/div ±(% of set value + mv) to 5 V/div ±(% of set value +0 mv) Inter-channel isolation: -0 db (typical. for the same range) Max input voltage: 50 V(DC + AC peak) ( khz max) (CAT I&II, 77Vrms) Input impedance: MΩ ±.5% (approx. 6 pf) Input coupling: AC/DC/GND Example of inserting a hard copy image on the screen of the into application software of a personal computer Saving acquired data You can save a captured waveform to an FD or an MO disk using a binary or ASCII format. If you save the waveform in a binary format, you can load it once again, or display it on a personal computer using viewer software that we provide. Measure save function (saves the results of automatically measuring a waveform parameter.) You can save the results of up to 5 parameter measurements to an FD or an MO disk using the ASCII format. You can read and analyze the results of spreadsheet calculations. LOGIC PROBE & LOGIC PROBE INPUT UNIT (optional) Eight-bit logic inputs become observable instead of one analog signal input. The probe and unit enables multi-channels to be simultaneously observed when measuring hybrid signals of mixed analog and digital data. These further support triggers using logic inputs. Horizontal section Sweep time: ns/div to 50 s/div Time axis accuracy: ±(0.0% ps) * Max record length: (500 kw/ch model) M words ( MW/ch model) (8 MW/ch model) External clock input: EXT CLOCK IN input 0 Hz to 00 MHz *3 Trigger Mode: AUTO/NORMAL (SINGLE acquisition by the single start key) Source: Input channel/ext Slope: Rise/fall/both Coupling: AC/DC Sensitivity: div p-p (DC to ) *6 Type: Edge/gate/A B (n) / A Delay B/ Edge On A / OR / B > Time B < Time / B Time Out/Window (CH only) TV (CH only) NTSC/PAL/HDTV A and B are defined by parallel pattern combination External trigger input: Range: ± V Trigger level: ± V/setting resolution 5 mv Frequency band: DC to 00 MHz Screen update speed When channel is used: Max 80 displays per screen When 8 channels are used: Max 7 displays per screen Storage media 3.5 inch FDD: 60 KB/70 KB/. MB/. MB(MS-DOS) 3.5 inch MO (option): 8 MB/30 MB read and write Display LCD: Number of display traces: 8.-inch TFT, color (60 80 dots) Max. 8 3 analog traces (in Zoom mode) Max. 3 analog digital traces (with /F3 option and logic probes, in Zoom mode) Logic probe Waveform calculations Types of calculations: Standard: +,,, phase, binary, power spectrum With user define math function (/M option): Math description: A formula can be defined in Math, Math area. Traces described in Math: C to C8 (From channel to channel 8) Traces described in Math: C to C8 (From channel to channel 8), Math Number of characters used in Math, Math : 50 characters * : Reference temperature condition (3± C, 55±0% RH) After calibration following warmup for 30 minutes * : Reference temperature condition (3± C, 55±0% RH) After warmup for 30 minutes * 3 : Continuous clock signal only * : mv/div can be realized at 5 mv/div zoom. * 5 : At a range other than mv/div. The voltage axis at the mv/div range is as follows: ±(3% of 8 div + offset voltage accuracy) * 6 : div p-p at mv/div (DC to )
6 Supported computation Calculus: DIF(), DDIF(), INTG(), IINTG() Pulse width computation: PWHH(), PWHL(), PWLH(), PWLL(), PWXX() FFT related: Linear spectrum, RMS spectrum Power spectrum, etc. Others: ABS(absolute value), SQR(squre root), LOG EXP, ATAN, MEAN(mean value) ^, ^3, ph (phase function), BIN (binary function) HLBT (Hilbert transform), Digital filter Record length used for calculations: 50 k words With /M option, the record length can be increased to M words (up to 0 K words in the case of the FFT) Standard Accessories Name Power cable Probe (700998) Instruction manual 3.5-inch floppy disk Quantity Number of channels Expansion function GO/NO-GO evaluation: Parameter evaluation: Evaluation can be made using a combination of 8 parameters. Waveform parameter automatic measurement: Up to items per trace. Parameters for 8 traces can be measured simultaneously. Max 8 items + statistical measurement results can be displayed. Image format saving: Snapshot: Accumulation: Roll mode: HP-GL, PostScript, TIFF, and BMP formats By pressing the snapshot key, waveforms can be accumulated on the screen without limit From screens to 8 screens, INFINITE (limitless time) Color accumulation From 00 ms/div; From 00 ms/div ( MW use) From 500 ms/div (8 MW use) ; From s /div (6 MW use) Sequential store function: Min. dead time 0 µs Envelope function: Peak value can be captured at 00 MS/s regardless of Time/div History memory function: Holds up to 8000 screens Interface GP-IB Electrical and mechanical specifications: IEEE std Protocol: IEEE std SCSI supported SCSI devices HDD: Drive formattable by EZ-SCSI MO drive: Up to 60 MB type. formattable by EZ-SCSI Zip drive: Lomega Zip drive compatible Logic probe input unit (/F3 option) specifications Number of logic input / connector 8 Number of usable connectors: Up to half of the analog input can be assigned for logic inputs. Input type: Ground common Display area: 8 bit digital signal is displayed in the corresponding analog signal display area Logic probe (700985) specifications Number of inputs: 8 Maximum input voltage: ± 0 V (DC + AC peak) Threshold level: Variable Frequency bandwidth: DC to 80 MHz Input impedance: MΩ ±.5%, 6 pf Signal input/output TRIG OUT: RGB output: Calibration output: TTL level VGA compatible, D-Sub 5 pin khz, V p-p, square wave Built-in printer (option) Printing method: Thermal write dot method ( mm width) Dot density: 6 dots/mm General specifications Operation temperature range: 5 to 0 C Operation humidity range: 0 to 85% RH (when printer is not used) 35 to 85% RH (when printer is used) Power source voltage: 90 to 3 V AC, 98 to 6 V AC (Automatically switched) Power source frequency: 8 to 63 Hz Power consumption: 650 VA max External dimensions: 6(W) (H) 5(D) mm (Excluding projection) Weight: Approx. 7 kg (main unit only) AVAILABLE MODELS Model Power voltage Power cable Option Suffix Codes D -F -Q -R /B5 /M /C3 /M /F3 Description ch, 500 kw/ch model ch, 500 kw/ch model 6 ch, 500 kw/ch model 8 ch, 500 kw/ch model ch, MW/ch model ch, MW/ch model 6 ch, MW/ch model 8 ch, MW/ch model ch, 8 MW/ch model ch, 8 MW/ch model 6 ch, 8 MW/ch model 8 ch, 8 MW/ch model 00 to 0 V 0 to 0 V UL, CSA standard VDE standard BS standard SAA standard Built-in printer * MW computation extension Internal MO drive * User define math function Logic probe input unit * 3 * roll chart (B9850NX) is included. * MO disk is included * 3 Logic probe (700985) is optional accessory. Please order the probe separately. (Number of usable logic probe varies depending on the model.) Accessories (optional) Name Ligic probe 50Ω terminator Code Spares Name Model/part No. Printer paper roll B9850NX passive probe Related Products Name Model/part name Isolation input unit DIMENSIONS (0.7) Specifications For logic input unit (/F3 option) Through type Order Q ty Specifications Order Q ty 30 m ( roll per instrument) 5 0 MΩ (0:),.5 m ( per instrument) Specifications channels, 30 MHz, with probes 6 (6.77) (6.58) (0.7) Order Q ty Unit: mm (approx. inch) 8 (.0) 0 (0.79) (8.7)
DIGITAL OSCILLOSCOPES & DIGITAL SCOPES
7050/7050/70505/7055 Digital Oscilloscopes DL540/DL540L/DL50/DL50L FUNCTIONS SIGL OBSERVATION USING LONG MEMORY Capturing Signals Using Long Memory for Accurate Waveforms The DL50/DL540 can continuously
More informationIn the development of electronic instruments or the analysis
DL2700 MULTICHANNEL, LONG-RECORDING DIGITAL OSCILLOSCOPE SHIBUYA Manabu * 1 FUKUZAWA Hitoshi * 1 TAKEZAWA Shigeru * 1 We have developed a digital oscilloscope with a maximum of 8 input channels, a maximum
More informationDIGITAL OSCILLOSCOPES
70530 & 70540 Digital Oscilloscopes DL 540C & DL 540CL The DL540CL, is Available with a New I 2 C* Bus Analysis Option. This Turns the DL540CL into an I 2 C Bus Analyzer. *: Serial interfaces between ICs
More informationDigital Storage Oscilloscopes 2550 Series
Data Sheet Digital Storage Oscilloscopes 2550 Series The 2550 series digital storage oscilloscopes provide high performance and value in 2-channel and 4-channel configurations. With bandwidth from 70 MHz
More informationWAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value
WAVEJET 300 SERIES OSCILLOSCOPES Unmatched Performance, Portability, and Value 1 WAVEJET 300 SERIES Unique Capabilities in a Low Bandwidth Oscilloscope The WaveJet 300 Series features unmatched performance
More informationWAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value
WAVEJET 300 SERIES OSCILLOSCOPES New Cover to Come Unmatched Performance, Portability, and Value ALL THE TOOLS YOU NEED Automatic Measurements Save time making measurements on your signals by using the
More informationScopeMeter 190 Series Specifications
Seite 1 von 7 ScopeMeter 190 Series Specifications Product Home Features Specifications Models, Options & Accessories Oscilloscope Mode Meter Mode Recorder Mode General Specifications Oscilloscope Mode
More informationAgilent Technologies 54522A
Agilent Technologies 54522A Data Sheet Product Specifications General Specifications Maximum Sample Rate 54522A 2 GSa/s Number of Channels (all are simultaneous acquisition) 54522A: 2 Record Length 32,768
More informationOscilloscope Guide Tektronix TDS3034B & TDS3052B
Tektronix TDS3034B & TDS3052B Version 2008-Jan-1 Dept. of Electrical & Computer Engineering Portland State University Copyright 2008 Portland State University 1 Basic Information This guide provides basic
More informationThe New Standard COLOR, Advanced Functions, Readability and Portability. Digital Oscilloscope
The New Standard COLOR, Advanced Functions, Readability and Portability Digital Oscilloscope DL540C/DL540CL 200 MS/s maximum sampling rate 50 MHz analog bandwidth Maximum record length: 2 M words for DL540CL,
More informationSMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.
9310A Family Digital Oscilloscopes 400 MHz Bandwidth, 100 MS/s Main Features Two and Four Channel Versions 50k, 200k and 1M Point Records DOS Compatible Floppy Disk, PCMCIA portable hard drive and Memory
More informationAnalog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube
TS-81000 DC 1 GHz, 4 CH, 15 traces TS-80600 DC 600 MHz, 4 CH, 15 traces There is the world, only Analog can capture it! State of the art Analog Oscilloscope As technology advanced rapidly, it is getting
More informationPortable Performance for Debug and Validation
WaveJet 300A Oscilloscopes 100 MHz 500 MHz Portable Performance for Debug and Validation A UNIQUE TOOLSET FOR PORTABLE OSCILLOSCOPES Key Features 100 MHz, 200 MHz, 350 MHz and 500 MHz bandwidths Sample
More informationNEW SPI bus (synchronous 8-bit serial bus) analysis function CAN bus signal analysis function (optional) with DL7200
Digital Oscilloscopes DL7200: Max. 2 GS/s; max. 6 MW/channel (with 70440) 4 MW/channel (with 70430) DL700: Max. GS/s; max. 8 MW/channel (with 70420) 2 MW/channel (with 7040) 4 analog input channels and
More informationSDS1000C Specifications
SDS1000C Specifications File Version V1.2 Siglent technology Co., Ltd CHARACTERISTIC: The highest Single real-time sampling rate can be up to 500MHzsa/s; Equivalent sampling rate is up to 10GSa/s. Memory
More informationExpect to Make Waves.
Expect to Make Waves. The New Oscilloscope Large 10.4" LCD touch screen Long capture time Extensive communication capabilities www.lecroy.com The New Oscillos From its large 10.4" LCD touch screen to its
More informationRIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.
RIGOL Data Sheet Product Overview DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial
More informationAnalog Arts SA985 SA975 SA935 SA915 Product Specifications [1]
www.analogarts.com Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1] 1. These models consist of an oscilloscope, a spectrum analyzer, a data recorder, and a frequency & phase meter. Oscilloscope/
More informationAnalog Arts SA985 SA975 SA935 SA915 Product Specifications
Analog Arts SA985 SA975 SA935 SA915 Product Specifications Oscilloscope/ Spectrum Analyzer/ Data Recorder Model SA985 SA975 SA935 SA915 Oscilloscope (Typical by Design) Bandwidth (Max at probe tip) [1]
More informationPRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment
Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency
More informationPicoScope 6407 Digitizer
YE AR PicoScope 6407 Digitizer HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator
More informationR3267/3273 Spectrum Analyzers
R3267/3273 Spectrum Analyzers For 3rd-Generation Mobile Communications Present Digital Communication standards (W-CDMA, PDC, PHS, IS-136, GSM, DECT, cdmaone ) R3267/3273 New communication technologies
More information2016 RIGOL TECHNOLOGIES, INC.
RIGOL Data Sheet Product Overview DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial
More informationMSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer
Link Instruments Innovative Test & Measurement solutions since 1986 Store Support Oscilloscopes Logic Analyzers Pattern Generators Accessories MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer $ The
More informationPROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES
Programmable DC Source Sink and Source Capability Conventional DC sources usually have the function of power supply (source) only without power absorption (sink) function. In addition to the source function,
More informationPicoScope 6407 Digitizer
YE AR HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator USB-connected Signals Analysis
More informationWaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz
WaveSurfer MXs The Specs You Want The Features You Need 200 MHz to 1 GHz The Essential Tools for Efficient Validation and Debug Leading Features Bandwidths from 200 MHz to 1 GHz Up to 5 GS/s Long Capture
More informationDigital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)
Digital Delay / Pulse Generator Digital delay and pulse generator (4-channel) Digital Delay/Pulse Generator Four independent delay channels Two fully defined pulse channels 5 ps delay resolution 50 ps
More informationHewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Frequency Hewlett Packard 3577A 5Hz - 200 MHz Network Analyzer Specifications SOURCE 5 Hz - 200 MHz 0.001 Hz Amplitude
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) This product is no longer carried in our catalog. AFG 2020 Characteristics Features Ordering Information Characteristics
More informationAgilent 5345A Universal Counter, 500 MHz
Agilent 5345A Universal Counter, 500 MHz Data Sheet Product Specifications Input Specifications (pulse and CW mode) 5356C Frequency Range 1.5-40 GHz Sensitivity (0-50 deg. C): 0.4-1.5 GHz -- 1.5-12.4 GHz
More informationReference. TDS7000 Series Digital Phosphor Oscilloscopes
Reference TDS7000 Series Digital Phosphor Oscilloscopes 07-070-00 0707000 To Use the Front Panel You can use the dedicated, front-panel knobs and buttons to do the most common operations. Turn INTENSITY
More informationSDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz
SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz Features 500MSa/s & 1GSa/s Sampling Rate 2 Channels / 4 Channels 7
More informationEMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C
A Electric Power / Controls 2 kw EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C GENERAL DESCRIPTION The Lab-Volt Data Acquisition and Management for Electromechanical Systems (LVDAM-EMS),
More informationTwo Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series
Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series U 10 to 25 MHz Bandwidths U Up to 200 MS/s Sampling Rate U Advanced Digital Triggers U Persistence Display Modes U Mask Limit
More informationADS1000C, CAL / CML Series
ADS1000C, CAL / Series DIGITAL STORAGE OSCILLOSCOPE 25MHz, 40MHz, 60MHz, 100MHz, 150MHz, 200MHz ADS1000 C Series ADS1000 CAL/ FEATURES APPLICATIONS 500MSa/s & 1GSa/s Sampling Rate 2 Channels 7 Widescreen
More informationSX-METRO A software package to meet all your needs
SX-METRO A software package to meet all your needs SX-METRO Software Front panel contact software The OX 863 and the OX 803 can be fitted with an RS232 interface (option) for controlling and programming
More informationMINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure
MINI PC SCOPE PCSU01 User manual Features test leads software download USB cable design enclosure Specifications oscilloscope: o bandwidth: DC to 200 khz ± 3 db o input impedance: 100 ko / 20 pf o maximum
More informationDDA-UG-E Rev E ISSUED: December 1999 ²
7LPHEDVH0RGHVDQG6HWXS 7LPHEDVH6DPSOLQJ0RGHV Depending on the timebase, you may choose from three sampling modes: Single-Shot, RIS (Random Interleaved Sampling), or Roll mode. Furthermore, for timebases
More informationDataSheet. SDS1000DL Series Digital Oscilloscope
DataSheet SDS1000DL Series Digital Oscilloscope CHARACTERISTIC: The highest Single real-time sampling rate can be up to 500MHzsa/s; Equivalent sampling rate is up to 50GSa/s. Memory Depth: 32Kpts Trigger
More informationModel 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02
Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 A fully integrated high-performance cross-correlation signal source analyzer from 5 MHz to 33+ GHz Key Features Complete broadband
More informationPORTABLE OSCILLOSCOPE
PORTABLE OSCILLOSCOPE Model OX 7104-CK 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Five complementary tools in one: Oscilloscope, Multimeter, FFT Analyzer, Harmonic Analyzer
More informationThe Measurement Tools and What They Do
2 The Measurement Tools The Measurement Tools and What They Do JITTERWIZARD The JitterWizard is a unique capability of the JitterPro package that performs the requisite scope setup chores while simplifying
More information2 MHz Lock-In Amplifier
2 MHz Lock-In Amplifier SR865 2 MHz dual phase lock-in amplifier SR865 2 MHz Lock-In Amplifier 1 mhz to 2 MHz frequency range Dual reference mode Low-noise current and voltage inputs Touchscreen data display
More informationWaveform Monitor/Vectorscope, PM 5661 Waveform Monitor/Vectorscope, Sc-H, PM 5661/70
Waveform Monitor/Vectorscope, PM 5661 Waveform Monitor/Vectorscope, Sc-H, PM 5661/70 Two instruments combined in one unit PM 5661/70 features Sc-H phase display Input Signal Subtraction (A-B) for easy
More informationData Pattern Generator
Data Pattern Generator DG2040 * DG2030 * DG2020A * P3410/P3420 Characteristics DG2040. Features Specs Ordering Information Pricing Information Print Data Sheet (61kB) Request a Quote Output Data Data Rate
More informationWVR500 Waveform/Vector Monitor
Service Manual WVR500 Waveform/Vector Monitor 070-8897-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are
More informationMICROWAVE MEASURING INSTRUMENTS
ICROWAVE SYSTE ANAYZER E453//, E538// 70 Hz band 70/140 Hz band Custom-made product OPTION The E453 and E538 series are used to measure the transmission line characteristics in the BB and IF bands in terrestrial
More informationAgilent Series Oscilloscopes
Agilent 54600-Series Oscilloscopes Data Sheet 60/100/150/500 MHz bandwidth models with 2 or 4 channels Easy-to-use analog front panel Fast, responsive display Automatic measurements Pretrigger viewing,
More information4 MHz Lock-In Amplifier
4 MHz Lock-In Amplifier SR865A 4 MHz dual phase lock-in amplifier SR865A 4 MHz Lock-In Amplifier 1 mhz to 4 MHz frequency range Low-noise current and voltage inputs Touchscreen data display - large numeric
More informationDigital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories
Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories SIGLENT TECHNOLOGIES 产品手册 PRODUCT CATALOG SIGLENT TECHNOLOGIES CO.,
More information~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.
-", " ; ~~~\_:;Jc:::~r ~.Yr / ~ jlf+ll t""'1 JJaJI..:.IWI."..JI 1. Analog bandwidth (-3dB ): 100 MHz 2. Analog input channels: 2 3. Calculated rise time: :5 3.5 ns 4. Time base range: 5 ns/div to 50 s/div
More information50 MHz Digital Storage Oscilloscope
DSC-5300 50 MHz Digital Storage Oscilloscope Applications The DSC-5300 Series Signal Generators are ideally suited for applications where value and quality are equally important such as for: zeducational
More informationPicoScope 4000 Automotive PC Oscilloscopes
PicoScope 4000 Automotive PC Oscilloscopes User's Manual ps4000a.en-1 Copyright 2008 Pico Technology Ltd. All rights reserved. Contents I Contents 1 Introduction...1 1 Overview...1...1 2 Minimum PC requirements...2
More informationBenefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope
Benefits of the R&S RTO Oscilloscope's Digital Trigger Application Note Products: R&S RTO Digital Oscilloscope The trigger is a key element of an oscilloscope. It captures specific signal events for detailed
More informationPicoScope 3000 Series Automotive User guide
PicoScope 3000 Series Automotive User guide PS3000A044 v1.0 I PicoScope 3000 Series Automotive PC Oscilloscopes Table of Contents 1 Introduction...2...2 1 Overview...2 2 Minimum PC requirements...2 3 Installation
More information, New REC&MEM Function New Recording Logger and Oscilloscope. MEMORY HiCORDER. Recorders / Digital Oscilloscope
MEMORY HiCORDER 8860-50,8861-50 Recorders / Digital Oscilloscope New REC&MEM Function New Recording Logger and Oscilloscope These models feature personal computer-like operability with mouse and keyboard
More informationDataSheet SDS1000CFL Series Digital Oscilloscope
DataSheet SDS1000CFL Series Digital Oscilloscope CHARACTERISTIC: The volume of the oscilloscope is cabinet and it is portable 7 Color TFT LCD display 2/4 channels, Bandwidth: 70MHz-300 MHz Single real-time
More information7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System
7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System A fully integrated high-performance cross-correlation signal source analyzer with platforms from 5MHz to 7GHz, 26GHz, and 40GHz Key
More informationDIGITAL TRANSMISSION MEASURING INSTRUMENTS
DIGITAL DATA ANALYZER MP1630B 10 khz to 200 MHz NEW GPIB OPTION The MP1630B is a general-purpose bit error measuring instrument that can provide simultaneous measurements of multi-channel signals and burst
More information8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Page 1 of 5 8500A The Giga-tronics 8500A Series Peak Power Meters THE ACCURACY STANDARD channel capability. For tests
More informationDigital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display
Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display SR850 DSP Lock-In Amplifier 1 mhz to 102.4 khz frequency range >100 db dynamic reserve 0.001 degree phase resolution Time constants
More informationData Pattern Generator DG2020A Data Sheet
Data Pattern Generator DG2020A Data Sheet DG2000 Series Features & Benefits Data Rate to 200 Mb/s Data Pattern Depth 64 K/channel Speeds Characterization Multiple Output Channels Increases Flexibility
More informationTSG 90 PATHFINDER NTSC Signal Generator
Service Manual TSG 90 PATHFINDER NTSC Signal Generator 070-8706-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless
More informationRICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury
RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury INTC 1307 Instrumentation Test Equipment Teaching Unit 8 Oscilloscopes Unit 8: Oscilloscopes
More informationR&S RT-Zxx High-Voltage and Current Probes Specifications
R&S RT-Zxx High-Voltage and Current Probes Specifications Test & Measurement Data Sheet 14.00 CONTENTS Definitions... 3 Probe/oscilloscope chart... 4 R&S RT-ZH10/-ZH11 high-voltage probes... 5 R&S RT-ZD01
More informationWAVERUNNER 104XI AND 204XI
WAVERUNNER 104XI AND 204XI Leading Features 1 and 2 GHz Bandwidths 5 GS/s Sample Rate (10 GS/s interleaved) 10 Mpts/Ch standard Large Display and Small (6" deep) footprint Most complete problem solving
More informationAgilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
More informationOSCILLOSCOPES-ANALYZERS
OSCILLOSCOPES-ANALYZERS portable and self-contained 40 and 100 MHz OX 7042 OX 7102 OX 7104 From the laboratory to the field, from diagnostics to appraisals, for desktop/portable use, a unique instrument!
More information16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE
PicoScope 4262 HIGH-RESOLUTION USB OSCILLOSCOPE A digital oscilloscope for the analog world Low noise Two channels 16 MS buffer 16-bit resolution 10 MS/s sampling 5 MHz bandwidth Advanced digital triggers
More informationHP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications
HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications 100 Hz to 26.5 GHz The HP 71910A/P is a receiver for monitoring signals from 100 Hz to 26.5 GHz. It provides a cost effective combination
More informationDatasheet SHF A
SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23D 12277 Berlin Germany Phone +49 30 772051-0 Fax ++49 30 7531078 E-Mail: sales@shf.de Web: http://www.shf.de Datasheet SHF 19120 A 2.85 GSa/s
More informationSpectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X
HMS-X_bro_de-en_3607-0181-3X_v0200.indd 1 Product Brochure 02.00 Test & Measurement Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X 15.03.2016 15:24:06 1 Basic Unit + 3 Options Key facts Frequency range: 100
More informationWhat to look for when choosing an oscilloscope
What to look for when choosing an oscilloscope Alan Tong (Pico Technology Ltd.) Introduction For many engineers, choosing a new oscilloscope can be daunting there are hundreds of different models to choose
More informationDigital Phosphor Oscilloscopes
Digital Phosphor Oscilloscopes TDS5000 Series FEATURES & BENEFITS 1 GHz, 500, 350 MHz Bandwidth Models 2 and 4 Channel Models 5 GS/s Maximum Real-time Sample Rate Up to 8 MB Record Length 100,000 wfms/s
More informationSpectrum Analyzer 1.6 GHz 3 GHz HMS-X
Spectrum Analyzer 1.6 GHz 3 GHz 1 Basic Unit + 3 Options Your Spectrum Analyzer Key facts Frequency range: 100 khz to 1.6 GHz/3 GHz* 1 Spectral purity greater than -100 dbc/hz (at 100 khz) SWEEP from 20
More informationOPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications
OPTICAL SPECTRUM ANALYZER 600 to 750 nm GPIB High Performance for DWDM Optical Communications The is a diffraction-grating spectrum analyzer for analyzing optical spectra in the 600 to 750 nm wavelength
More informationR&S RT-Zxx High-Bandwidth Probes Specifications
R&S RT-Zxx High-Bandwidth Probes Specifications Test & Measurement Data Sheet 14.00 CONTENTS Definitions... 3 Probe/oscilloscope chart... 4 R&S RT-ZZ80 transmission line probe... 5 R&S RT-ZS10/-ZS10E/-ZS20/-ZS30
More informationSELECTION GUIDE Series of RF and Universal Frequency Counter/Timers
SELECTION GUIDE 53200 Series of RF and Universal Frequency Counter/Timers With the Keysight Technologies, Inc. 53200 RF and Universal Frequency Counters/Timers, You Get: More bandwidth 350 MHz baseband
More informationATS MS/s 8-Bit PCI Digitizer
2 channels sampled at 8-bit resolution 50 MS/s simultaneous real-time sampling rate on each input ±20mV to ±20V input range 256 Kilo samples of on-board acquisition memory per channel AlazarDSO Oscilloscope
More informationLeCroy Digital Oscilloscopes
LeCroy Digital Oscilloscopes Get the Complete Picture Quick Reference Guide QUICKSTART TO SIGNAL VIEWING Quickly display a signal View with Analog Persistence 1. Connect your signal. When you use a probe,
More informationEASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.
Multichannel Scaler Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. The ideal solution for: Time-resolved single-photon counting Phosphorescence lifetime spectrometry Atmospheric and
More informationG4500. Portable Power Quality Analyser. Energy Efficiency through power quality
G4500 Portable Power Quality Analyser Energy Efficiency through power quality The BlackBox portable series power quality analyser takes power quality monitoring to a whole new level by using the revolutionary
More informationOverview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators
Know Your Oscilloscope Overview Front Panel Sharing Agilent s Resources with Engineering Educators www.educatorscorner.com Horizontal (time) controls Run control Special purpose menus/controls Trigger
More informationDataSheet SDS1000CML Series Digital Oscilloscope
DataSheet SDS1000CML Series Digital Oscilloscope CHARACTERISTIC: The highest Single real-time sampling rate can be up to1gsa/s; Equivalent sampling rate is up to 50GSa/s. Memory Depth: 2Mpts Trigger types:
More informationUser Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03
General Safety Summary General Safety Summary User Manual Digital Storage Oscilloscopes Models 2534, 2540 & 2542 Review the following safety precautions to avoid injury and prevent damage to this product
More informationSMS3000X Series Spectrum Analyzer
Data Sheet SMS3000X Series Spectrum Analyzer SMS3032X SMS3021X General Description SMS3000X series spectrum analyzer has a frequency range from 9 khz up to 2.1 GHz/3.2 GHz, it is light weight and small
More informationSDS1000CNL+ Series Digital Oscilloscope. DataSheet
SDS1000CNL+ Series Digital Oscilloscope DataSheet-2016.5 Key Features 70 MHz, 100 MHz bandwidth models SDS1072CNL+ SDS1102CNL+ Real-time sampling rate up to 1 GSa/s, Equivalent-time sampling rate up to
More informationAdvanced Test Equipment Rentals ATEC (2832)
E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar
More informationBurlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix
v1.2 Burlington County College INSTRUCTION GUIDE for the Hewlett Packard FUNCTION GENERATOR Model #33120A and Tektronix OSCILLOSCOPE Model #MSO2004B Summer 2014 Pg. 2 Scope-Gen Handout_pgs1-8_v1.2_SU14.doc
More informationPart 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories
Part 2 LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories LT4610SER01 OPTION LTC IN/OUT GPS IN CW IN AES/EBU/OUT SILENCE OUT WCLK OUT ETHERNET GENLOCK
More informationDigitizing Oscilloscopes
Digitizing Oscilloscopes This document is meant to be a reference to the operation of the digitizing oscilloscopes available in the laboratories. Major topics will be covered, but not all the features
More information2 MHz Lock-In Amplifier
2 MHz Lock-In Amplifier SR865 2 MHz dual phase lock-in amplifier SR865 2 MHz Lock-In Amplifier 1 mhz to 2 MHz frequency range Low-noise current and voltage inputs Touchscreen data display - large numeric
More informationGFT Channel Slave Generator
GFT1018 8 Channel Slave Generator Features 8 independent delay channels 1 ps time resolution < 100 ps rms jitter for optical triggered delays 1 second range Electrical or optical output Three trigger modes
More informationOSCILLOSCOPE AND DIGITAL MULTIMETER
Exp. No #0 OSCILLOSCOPE AND DIGITAL MULTIMETER Date: OBJECTIVE The purpose of the experiment is to understand the operation of cathode ray oscilloscope (CRO) and to become familiar with its usage. Also
More information1. Abstract. Mixed Signal Oscilloscope Ideal For Debugging Embedded Systems DLM2000 Series
Yokogawa Electric Corporation High Frequency Measurement Development Dept. C&M Business HQ. Motoaki Sugimoto 1. Abstract From digital home electronics to automobiles, a boom has recently occurred in various
More informationGFT Channel Digital Delay Generator
Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Fours Triggers Three are repetitive from three
More informationOver 5000 VXI cards and mainframes in stock. 1000's of pieces of Test Equipment in stock. Looking for Test Equipment? Visit us on the web at www.recycledequipment.com Recycled Equipment buys, sells, and
More informationSignal Stability Analyser
Signal Stability Analyser o Real Time Phase or Frequency Display o Real Time Data, Allan Variance and Phase Noise Plots o 1MHz to 65MHz medium resolution (12.5ps) o 5MHz and 10MHz high resolution (50fs)
More informationHigh Speed Data Acquisition Cards
High Speed Data Acquisition Cards TPCE TPCE-LE TPCE-I TPCX 2016 Elsys AG www.elsys-instruments.com 1 Product Overview Elsys Data Acquisition Cards are high speed high precision digitizer modules. Based
More information