RICHARD B FISHER BUILDING TECHNICAL SPECIFICATIONS

Size: px
Start display at page:

Download "RICHARD B FISHER BUILDING TECHNICAL SPECIFICATIONS"

Transcription

1 BAM Fisher 321 Ashland Place Brooklyn, NY Revised by JE February 2015 RICHARD B FISHER BUILDING TECHNICAL SPECIFICATIONS BAM's technical specifications, seating charts, photos, stage drawings and more can be found on our private box.net website. Plans and Sections are available in AutoCAD, Vectorworks, and PDF (1/4 imperial and 1:50 metric scale). BAM s Production Manager for the site address and password. SEATING CAPACITY Stage 204 (maximum) Mezzanine 85 (maximum) LOAD-IN AREA The loading ramp is at street level and is in the alley between the BAM Opera House and the Fisher Building. The door opens directly onto the SR section of the stage. Directly outside the door is an 8-6 (2.59m) wide by 19-3 (5.87m) long platform. The platform is connected to the sidewalk via a 4-0 (1.22m) wide by 48-0 (14.63m) ramp. The loading door measures 6-0 (1.82m) wide by 7-4 (2.23m) high. The ramp and platform have a maximum weight limit of 1000lbs. All theatrical equipment will need to be able to make the turn into the door. January 2015 BAM Richard B Fisher Building Technical Specifications Page 1

2 FISHMAN STAGE DIMENSIONS Plans and Sections are available in AutoCAD, Vectorworks, and PDF (1/4 imperial and 1:50 metric scale). STAGE (NO SEATS) BALCONY GRID SEATING RISERS (COLLAPSED) TO BACK WALL SL WALL TO SR WALL DECK TO BOTTOM OF MEZZANINE WIDTH OF MEZZANINE WIDTH OF OPENING BETWEEN MEZZANINE DECK TO BOTTOM OF MESH GRID MEZZANINE TO BOTTOM OF MESH GRID MESH GRID TO UNISTRUT GRID MESH GRID TO LIGHTING PIPES 1-7 MESH GRID TO LIGHITNG PIPES A-C 53-3 (16.23m) (17.63m) 9-10 (3m) 8-0 (2.44m) 42-7½ (12.99m) 21-5 (6.53m) 10-7 (3.23m) 7-1 (2.16m) (1.08m) (1.13m) Dimensions for different seating arrangements can be requested. Please see the contact information at the end of this document. February 2015 BAM Richard B Fisher Building Technical Specifications Page 2

3 FISHMAN CARPENTRY CROSSOVERS Crossovers are possible under the stage. Stairway entrances downstairs are located UR and UL, and have restricted height and width. The lobby may also be used during performances for entrances DR and DL. STAGE FLOOR The floor is a sprung dance floor with a black ¼ masonite surface. Reversible (black and white) marley flooring is available. Each of the (7) available Marley floor pieces are 6 6 ¾ x 55 (2m x 16.76m). SOFT GOODS INVENTORY MAIN CURTAIN (2) Split ink blue velour 50% fullness each side 19 5 h x 23 w (5.92m x 6.17m) (1) Ink blue velour border 50% fullness 5 h x 42 w (1.52m x 12.80m) LEGS (4) Pair black velour 20 3h x 8 w (6.17m x 2.44m) BORDERS (3) Black velour 5 h x 42 w (1.52m x 12.80m) BLACKOUT DROPS (1) Black velour blackout drop 20 3 h x 42 w (6.17m x 12.80m) SCRIMS (1) Black sharkstooth scrim 20 3 h x 42 w (6.17m x 12.80m) (1) White sharkstooth scrim 20 5 h x 42 w (6.22m x 12.80m) PLASTIC CYC (1) White 20 5 h x 42 w (6.22m x 12.80m) OTHER (1) Full stage traveler track UNDER BALCONY MASKING (22) Black velour 8 10 h x 8 w (2.69m x 2.44m) STAGE RIGGING CHAIN HOIST MOTORS (4) Half ton CM chain hoist motors (4) Quarter ton StageMaker chain hoist motors PLATFORMS There are (46) 3 x6 aluminum framed stock platforms that can be legged up to any height. Standard platform heights are in 7 increments. The platforms are also used for audience seating in certain configurations. Availability of all platforms will be determined by BAM s Production Manager. February 2015 BAM Richard B Fisher Building Technical Specifications Page 3

4 FISHMAN ELECTRICS OVERVIEW Except during the Next Wave Festival there is a Repertory Light Plot in use. For Rep Plot policy and relevant inventory please see the Rep Plot Information section below. During the Next Wave Festival or when the Rep Plot is not in use, all inventory in the space is available. Please see the Fishman Lighting Inventory section below for the complete inventory. There are (6) Vari*Lites in the space: (3) stage left and (3) stage right. They are permanently installed and may not be moved or removed. There is a LEX PowerGate, 400A 120V/208V AC, three phase company switch in the basement. All CamLok connections are female. There is a Hubbell Circuit Lock 100A 120V/208V AC, three phase company switch on the Tension Grid level. There are (13) ETC NET3 2-port gateways available for DMX control, which connect to the lighting network. Connection points are located on the grid, balcony, and stage levels. DIMMERS There is a dimmer-per-circuit system in place. There are a total of 2.4kw ETC Sensor CEM+ dimmers. There are (36) at stage level, (12) at balcony level, and (216) at grid level. There are a total of (8) 110v and (4) 220v relays throughout the stage and grid levels. Dimmers and relay panels are located on the Mezzanine Level, Stage Left. CONTROL CONSOLE The Control Booth is located in the rear of the balcony level in the booth. The windows be can opened or removed. ETC ION console with synchronized backup and the following features: Full featured moving and conventional lighting console NET3 (ACN based) network system with 32 DMX universes DMX input/output available via Ethernet ports and portable ETC NET3 2-port gateways Offline programming on PC (Vista or XP) and native on Macintosh (OS X Power PC or Intel) Show data importing from Obsession, Express/ion, Emphasis and Strand 500/300 series show files via ASCII Ion web site: There is an RVI unit with dual monitors, keyboard, and mouse. HOUSE LIGHTS Optional dimming is available at the lighting console. The house lights can also be controlled via the Unison touchscreen panel in the booth. PERSONNEL LIFTS (1) Genie Runabout GR-20 single lift - maximum platform height 20-0 (6.10m) February 2015 BAM Richard B Fisher Building Technical Specifications Page 4

5 COMPLETE FISHMAN LIGHTING INVENTORY (7) ETC Source Four 14 (17) ETC Source Four 19 (41) ETC Source Four 26 (51) ETC Source Four 36 (25) ETC Source Four 50 (54) ETC Source Four PAR, with VNSP, NSP, MFL, and WFL lenses (10) ETC Source Four PAR XWFL lenses (4) Altman 6 Fresnels, 1kw (4) ARRI T2 7 Fresnels, 2kw (7) L& E MR16 Mini Strips, 6 0 length, 3-circuit, 30 lamps per circuit (24) Altman Focusing CYC Lights, 1kw, can be used as individual units or sets of 3 (6) Altman Spectra PAR 100, with VNSP, NSP, MFL, and WFL lenses (8) Altman Spectra CYC 200 (10) Vari*Lite VL1100TS ERS (1) Le Maitre Neutron XS Hazer, DMX controlled (1) Delta 3000 Fog Machine, DMX controlled (30) Source Four full top hats (22) Source Four short top hats (30) Source Four half hats (eyelashes) (35) Source Four short half hats (eyelashes) (12) Source Four 3 color extenders (16) Source Four 6 color extenders (10) Source Four PAR top hats (30) Source Four PAR 4 way barn doors (6) Altman Spectra PAR 4 way barn doors (4) ARRI Fresnel 4 way barn doors (45) Source Four PAR color extenders (10) Source Four drop-in irises (30) Source Four A size template holders (25) Source Four B size template holders (4) Source Four A size glass template holders (20) Donuts (25) 12 sidearms (35) 18 sidearms (18) 24 sidearms (2) 36 sidearms (12) 50lb Boom Bases (18) 10lb 6 Round floor bases (2) Vari*Lite floor stands REP PLOT INFORMATION There are nine (9) units in the Rep Plot that can be refocused. Please see the Rep Plot for indication of these specific units. Additional costs will likely apply for moving, adding, and/or refocusing beyond these (9) units. All units can be recolored. The following inventory is available to be added to the Rep Plot. Separate packages are available for booms and cyc lights, but will incur additional costs. ADDTIONAL INVENTORY (7) ETC Source Four 14 (8) ETC Source Four 19 (23) ETC Source Four 26 (14) ETC Source Four 36 (25) ETC Source Four 50 (24) ETC Source Four PAR, with VNSP, NSP, MFL, and WFL lenses (4) Vari*Lite VL1100TS ERS February 2015 BAM Richard B Fisher Building Technical Specifications Page 5

6 (6) Altman 6 Fresnels, 1k (4) ARRI T2 7 Fresnels, 2k (7) L& E MR16 Mini Strips, 6 0 length, 3-circuit, 30 lamps per circuit (24) Altman Focusing CYC Lights, 1kw (8 sets of three) (6) Altman Spectra PAR 100, with VNSP, NSP, MFL, and WFL lenses (8) Altman Spectra CYC 200 (12) Source Four full top hats (22) Source Four short top hats (30) Source Four half hats (eyelashes) (35) Source Four short half hats (eyelashes) (12) Source Four 3 color extenders (16) Source Four 6 color extenders (4) Source Four PAR top hats (9) Source Four PAR 4 way barn doors (6) Altman Spectra PAR 4 way barn doors (4) ARRI Fresnel 4 way barn doors (21) Source Four PAR color extenders (10) Source Four drop-in irises (25) Source Four A size template holders (25) Source Four B size template holders (4) Source Four A size glass template holders (20) Donuts (25) 12 sidearms (23) 18 sidearms (18) 24 sidearms (2) 36 sidearms (18) 10lb 6 Round floor bases (12) 50lb Boom Bases (2) Vari*Lite floor stands February 2015 BAM Richard B Fisher Building Technical Specifications Page 6

7 FISHMAN SOUND SYSTEM OVERVIEW The system consists of two zones, Center and Surround (House Left, House Right, Rear of House, and Stage). The Center Zone is made up of: Left, Right, Center, Delays and Sub. The Surround Zone consists of (18) loudspeakers: (6) on the North wall, (6) on the South Wall, (3) on the East Wall, and (3) on the West Wall. All zones can be controlled separately. Please see drawing package for specific loudspeaker locations. All loudspeakers are time-aligned with preset delays via the Meyer Galileo Loudspeaker Management System. Standard EQ consists of a low pass on the mains and a high pass on the subs. There is a Hubbell Circuit-Lock, 100A 120V/208VAC, three phase isolated ground company switch in the basement. The theater is equipped with a Sennheiser InfraRed Assistive Listening System. (4) Channel Clear-Com party line system with multiple drops at key locations throughout stage, house and all technical areas, along with an (8) channel CellCom wireless com system. There is a Cat6 infrastructure with tie lines throughout the building. MIXING LOCATIONS The Control Booth is located in the rear of the balcony level in the booth with windows. The windows be can opened or removed. An in house mix position is available in the balcony at the rear of the seating risers, just in front of the booth. (7) seats need to be removed to allow enough space for the mixing console and egress. This position is subject to approval by the Production Manager and General Manager. MIXING CONSOLE (1) Yamaha M7CL-48ES (3) Yamaha SB168-ES EtherSound stage boxes (2) MY16-AUD (1) MY16-AT LOUDSPEAKERS AND SYSTEM PROCESSING MAIN ZONE LEFT (1) Meyer UPA-1P (hung just above the tension grid) RIGHT (1) Meyer UPA-1P (hung just above the tension grid) CENTER (1) Meyer UPA-1P (hung just above the tension grid) DELAY (3) Meyer UPA-1P (hung just above the tension grid) SUBS (2) Meyer 500-HP (on balcony, USL and USR) SURROUND ZONES STAGE RIGHT (6) Meyer UPM-1P STAGE LEFT (6) Meyer UPM-1P UP STAGE (3) Meyer UPM-1P DOWN STAGE (3) Meyer UPM-1P ADDITIONAL LOUDSPEAKERS FOR GENERAL USE PER AVAILABILITY (2) Meyer UPA-1P (2) Meyer UPA-2P (4) Meyer UPJunior (2) Meyer 500-HP (2) Meyer UMS-1P SYSTEM PROCESSING (1) Meyer Galileo 408 (Main System) (1) Meyer Galileo 616 (Surround System) February 2015 BAM Richard B Fisher Building Technical Specifications Page 7

8 PLAYBACK COMPUTER PLAYBACK (1) Apple MacMini with QLab 3.0 (connects to console via Dante) CD/SOLID STATE RECORDER (1) Tascam SS-CDR200 MICROPHONE - FOR GENERAL USE PER AVAILABILITY SHURE (4) SM 57-LC (4) SM 58-LC (4) SM 58S-LC (2) BETA 87A (2) SM81 (2) SM137 (4) MX202B/C (2) MX418C SENNHEISER (2) MD-421 II (1) e 906 (2) e 604 DPA (4) DPA d:fine Black (2) DPA-4088 Black (3) DPA-4060 Black AKG (2) C414 XLS DIRECT BOXES (2) Whirlwind HOTBOX Active DI (2) Whirlwind DIRECT-JT Passive DI (2) BSS AR-133 (4) Radial ProD2 Stereo DI (1) Radial ProAV1 (1) Radial ProAV2 ACCESORIES (1) Radial Reamp (1) Artcessories MyMonitor (Personal Monitor Mixer) RF MICS AND SYSTEMS (2) Shure ULXD4Q G50 Receivers (8 channels) (8) Shure ULXD1 G50 Transmitters (8) Shure ULXD2 G50 Transmitters February 2015 BAM Richard B Fisher Building Technical Specifications Page 8

9 FISHMAN VIDEO Availability of all projection equipment will be determined by BAM s Production Manager. There is optical glass in the center pane of the Control Booth windows and the smaller outside panes to prevent loss of image quality. There is a Cat6 infrastructure with tie lines throughout the building. These can be patched into a Cisco Catalyst 2960-S Ethernet switch. There is a 3G-SDI infrastructure with tie lines throughout the building. PROJECTORS (3) Panasonic PT-DZ6710U DLP Multi Media Projector (6000 ANSI Lumens) ACCESSORIES (3) lens (Standard Lens) (2) lens (ET-DLE250) (1) lens (ET-DLE80) (1) Draper Screen 12 6 x20 (3.81m x 6.10m) (1) Barco DCS 200 Dual Channel Switcher (3) Chief RPMA6500 Mounts (1) BrightEye Mitto (DVI to HD-SDI) (8) TrippLite VGA Extenders (3) Aja HD5DA (HD/SD Distribution Amp) (3) Aja HI5 (HD-SDI to HDMI) (1) BlackMagic Audio to SDI Mini Converter (1) Bright Eye NXT 410 Clean HDMI Router PROPERTIES MUSIC STANDS (10) with lights, as available ORCHESTRA CHAIRS (10) Black Wenger Musician s Chairs LECTERNS (2) Lecterns TABLES & CHAIRS 6 plastic folding tables and folding chairs are available as necessary. WARDROBE FACILITIES There is a well-equipped separate wardrobe room located in the basement equipped with a laundry room with (2) front loading washing machines & (2) front loading dryers. WARDROBE EQUIPMENT (8) rolling clothing racks (2) steamers (2) clothing irons (2) ironing boards (2) portable sewing machines February 2015 BAM Richard B Fisher Building Technical Specifications Page 9

10 DRESSING ROOMS KEYS Dressing room locks are opened with a number code. They are available from the Production and Artist Services staffs. There are two dressing rooms, each accommodating 10 people. FLOOR PLAN OF ROOMS There is one ADA accessible room at stage level, two group dressing rooms in the basement (up to 20 people), and two group dressing rooms on the 4 th floor (up to 12 people). Access from the stage to the dressing rooms is via stairs. BATHROOMS AND FACILITIES All dressing rooms are equipped with bathroom facilities. Basement and 4 th Floor dressing rooms are also equipped with showers. VISITING COMPANY OFFICE There is an office in the basement designated for use by visiting companies with the following available for use: Computer with internet access. Printer. Phone line. GREEN ROOM There is no green room on the premises. Coffee and beverages are set up at the basement level. February 2015 BAM Richard B Fisher Building Technical Specifications Page 10

11 HILLMAN REHEARSAL STUDIO Plans and Sections are available in AutoCAD, Vectorworks, and PDF (1/4 imperial and 1:50 metric scale). The Hillman is on the fourth floor of the Fisher Building, with access via an elevator (elevator load-in dimensions:9 x 4 ) There are windows on the Ashland Pl side of the room, and mirrors on the other. A sunshade and blackout out shade are installed to cover the windows as needed. There is a double dance bar installed along the mirror wall. A split moleskin velour curtain is installed to cover the mirrored wall. STUDIO DIMENSIONS BALLET BAR TO WINDOWS NORTH WALL TO SOUTH WALL FLOOR TO BOTTOM OF TECH GALLERY 34-7 (10.54m) 43-0 (13.1m) (3.6m) February 2015 BAM Richard B Fisher Building Technical Specifications Page 11

12 STUDIO FLOOR The floor is a sprung dance floor with a wood surface. Reversible (black and grey) marley flooring is available. Each of the (5) available Marley floor pieces are 6 6 ¾ x 42 (2m x 12.8m). Availability of platforms, and theatrical seats will be determined by BAM s Production Manager. Folding chairs and 6 tables are available as necessary TRUSS (3) 30 total length made up of (3) 10 sections of 12 x 12 JT Supertruss are hung in the Hillman. Capacity is 2,000lbs for an evenly distributed load, and 1,500lbs for a point load. HILLMAN ELECTRICS There is a Hubbell Circuit-Lock, 100A 120V/208VAC, three phase company switch located in an adjacent room off the South Side of the studio. DIMMERS All dimmers are part of the dimmer-per-circuit system in place. There are (84) 2.4kw ETC Sensor dimmers; (60) on the tech gallery level, (24) on the floor level. Dimmers are located in the Fishman Space dimmer room. CONTROL CONSOLE HOUSE LIGHTS ETC ION (see specs above) Dimmable at console REP LIGHT PLOT (3) 19 Source Fours 575w (2) 26 Source Fours 575w (7) 36 Source Fours 575w (16) 50 Source Fours 575w (3) 6 Fresnels 1kw 575w HILLMAN SOUND LOUDSPEAKERS (4) Meyer UPA-1P (hung at each corner of the room) MIXING CONSOLE (1) Yamaha QL3 w/ RIO1608 Stage Box PLAYBACK (1) Tascam SS-CDR200 RF MICS AND SYSTEMS (1) Shure ULXD4Q G50 Receivers (4 channels) (4) Shure ULXD1 G50 Transmitters (4) Shure ULXD2 G50 Transmitters HILLMAN VIDEO PROJECTORS (1) Panasonic PT-DZ6710U DLP Multi Media Projector (6000 ANSI Lumens) ACCESSORIES (1) lens (Standard Lens) (1) Draper Screen 8 3/4 x14 (2.7m x 4.3m) (1) Chief RPMA6500 Mount February 2015 BAM Richard B Fisher Building Technical Specifications Page 12

13 INTERNATIONAL FREIGHT Normal U.S. Customs clearance usually takes 3-4 days But there can sometimes be added security holds which could delay clearance for another 4-5 days if they decide to X-ray the container(s), or another, additional two weeks if they decide to de-van the shipment for inspection. While Customs does regularly see BAM as the consignee on a lot of theatrical shipments that do not have problems clearing Customs, and consequently will infrequently if ever go to the extra lengths to inspect our freight, it's always possible, and we will try to plan for the worst case-- so we suggest that a minimum of two weeks and preferably three would be advisable between arrival in New York and the needed load in date at BAM. OPEN FLAME and EFFECTS Companies coming into BAM must provide BAM with all necessary flame proofing documentation for their scenery, stage properties, and costumes, and information as necessary for all open flame effects, including the use of cigarettes, etc. BAM will make all reasonable efforts to obtain the appropriate open flame permits; however, the use of all open flame is at the sole discretion of the New York City Fire Department. For further information, please contact: Production Department Brooklyn Academy of Music 30 Lafayette Ave. Brooklyn, New York , USA Telephone: (718) Fax: (718) February 2015 BAM Richard B Fisher Building Technical Specifications Page 13

TECHNICAL SPECIFICATIONS Richard B. Fisher Building

TECHNICAL SPECIFICATIONS Richard B. Fisher Building TECHNICAL SPECIFICATIONS Richard B. Fisher Building Version: January, 2018 Brooklyn Academy of Music Revised: January 31, 2018 30 Lafayette Ave Revised By: R. Gastelum Brooklyn NY, 11217 Phone: 718 636

More information

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY VICTORIA THEATER TECHNICAL SPECIFICATIONS Correct as of 11.08.07 Page 1 of 7 LOAD IN The Victoria Theater stage is directly accessible via loading dock

More information

Lighting Information

Lighting Information Lighting Information PLEASE NOTE THAT THE ENTIRE INVENTORY MAY NOT BE AVAILABLE FOR YOUR PRODUCTION. PLEASE CONFIRM INVENTORY WITH THE TECHNICAL DIRECTOR AT LEAST 30 DAYS PRIOR TO YOUR EVENT. Welcome to

More information

Technical Information Packet As of October 2017

Technical Information Packet As of October 2017 Technical Information Packet As of October 2017 Contents General Information Theatre Specifications Soft Goods Lighting Sound Video Assisted Listening Dressing Rooms / Performer Support Burlington Map

More information

Downtown Arts Center Tech Packet. General Information

Downtown Arts Center Tech Packet. General Information General Information Box Office: 859.425.2550 City Gallery: 859.425.2562 Center Director: 859.425.2349 Technical Director: 859.425.2582 www.lexingtonky.gov/dac Address: Downtown Arts Center 141 East Main

More information

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013 TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA 01420 UPDATED March 2013 Cultural Affairs Office: 978-665-3709 Web Site: www.fitchburgstate.edu/cultural

More information

SCHEDULE F EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE

SCHEDULE F EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE INCLUDED EQUIPMENT SCHEDULE F EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE Current as of July 18, 2018 ** The equipment specifications and inventory provided below is subject to change before the start

More information

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee Audio Equipment (Audio Equipment Continued...) Console Cable MIDAS VERONA ( channels)

More information

Project manager (PM): Pamela Næss Mail: Phone:

Project manager (PM): Pamela Næss Mail: Phone: TECHNICAL SPECIFICATIONS FOLKETEATERET OSLO AS STORGATA 21-23, 0184 OSLO NORWAY (LOAD IN THROUGH CARPORT AT YOUNGSTORGET 2) CAPACITY 1395 PEOPLE 764 ORCESTRA AND 615 BALCONY 2x6 seat boxes on orchestra,

More information

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION Stage Stage Dimensions: Theater dimensions: Mainstage - 60 0 wide x 28 9 deep. Proscenium arch - 41 6 wide x 28 0 tall. Load gallery on SR

More information

SHUBERT THEATER 247 College Street, New Haven, CT

SHUBERT THEATER 247 College Street, New Haven, CT SHUBERT THEATER 247 College Street, New Haven, CT 06510 203-624-1825 TECHNICAL SPECIFICATIONS and EQUIPMENT INVENTORY HALL SEATING CAPACITY Orchestra 665 Mezzanine 474 Balcony 392 Boxes 60 TOTAL 1591 STAGE

More information

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details. Technical Information Centerville Performing Arts Center Centerville High School 500 E. Franklin Street, Centerville, OH 45459 Theatre Manager: Mike Cordonnier Office: 937-439-3535, Fax: 937-439-3574 E-Mail:

More information

Marjorie S. Deane Little Theater

Marjorie S. Deane Little Theater THEATER LOCATION Marjorie S. Deane Little Theater Public access at 5 West 63 rd street, New York, NY 10023. performances only at 10 West 64 th street. Directions to Loading Entrance at 10 West 64 th street:

More information

EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE

EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE INCLUDED EQUIPMENT EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE Current as of May 19, 2017 ** The equipment specifications and inventory provided below is subject to change before the start of your rental,

More information

TECHNICAL SPECIFICATIONS HOWARD GILMAN OPERA HOUSE

TECHNICAL SPECIFICATIONS HOWARD GILMAN OPERA HOUSE TECHNICAL SPECIFICATIONS HOWARD GILMAN OPERA HOUSE Version: January 2018 Brooklyn Academy of Music Revised: January 31, 2018 30 Lafayette Ave Revised By: R. Gastelum Brooklyn NY, 11217 Phone: 718 636 4146

More information

Project manager (PM): Pamela Næss Mail: Phone:

Project manager (PM): Pamela Næss Mail: Phone: TECHNICAL SPECIFICATIONS FOLKETEATERET OSLO AS STORGATA 21-23, 0184 OSLO NORWAY (LOAD IN THROUGH CARPORT AT YOUNGSTORGET 2) CAPACITY 1395 PEOPLE 764 ORCESTRA AND 615 BALCONY 2x6 seat boxes on orchestra,

More information

Technical Specifications

Technical Specifications FOLLY THEATER 300 W. 12th Street Kansas City, Missouri 64105 Technical Specifications CONTACT INFORMATION Stephanie Spatz-Ornburn, Event Manager Lee Saylor, Technical Director Business Office: (816) 842-5500

More information

EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE

EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE INCLUDED EQUIPMENT EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE Current as of October 20, 2016 ** The equipment specifications and inventory provided below is subject to change before the start of

More information

TECHNICAL SPECIFICATIONS LEPERCQ

TECHNICAL SPECIFICATIONS LEPERCQ TECHNICAL SPECIFICATIONS LEPERCQ Version: January 2018 Brooklyn Academy of Music Revised: January 31, 2018 30 Lafayette Ave Revised By: R. Gastelum Brooklyn NY, 11217 Phone: 718 636 4146 Fax: 718 857 166

More information

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Dr. Fred Speckeen Theatre. Information and Technical Specifications Dr. Fred Speckeen Theatre Information and Technical Specifications Location Fairview Alberta Part of the Recreational complex of GPRC Fairview Loading Dock is at the East end Capacity The FST seats a maximum

More information

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER THEATER SPECIFICATIONS SEATING CAPACITY: 502 seats, as well as 8 spaces for wheel chairs, all on one biraked level. STAGE DIMENSIONS: DECK: Height from House floor = 3 5 Depth from Proscenium Arch to Cyclorama

More information

Patriots Theater at the War Memorial Technical Data

Patriots Theater at the War Memorial Technical Data Patriots Theater at the War Memorial Technical Data Stage House Dimensions Proscenium Opening: 50-0 wide x 25-0 high Batten Travel: 48-10 Batten Length: 60-0 Stage depth: 26 smoke pocket to back wall Pit

More information

FOX THEATRE ST. LOUIS

FOX THEATRE ST. LOUIS FOX THEATRE PAGE 1 OF 7 FOX THEATRE ST. LOUIS CONTACT INFORMATION THEATRE ADDRESS: STAFF CONTACTS: Fox Theatre 527 N. Grand St. Louis, MO 63103 John Wolf Vice President of Theatre Operations 314-657-5060

More information

Technical Services and Specification

Technical Services and Specification Technical Services and Specification BRAUNTEX PERFORMING ARTS THEATRE ASSOCIATION, INC. 290 West San Antonio New Braunfels, TX 78130 (830) 627-0808 FAX (830) 627-0809 Operations Manager: Ben Nowotny -

More information

EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE

EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE INCLUDED EQUIPMENT EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE Current as of May 19, 2017 ** The equipment specifications and inventory provided below is subject to change before the start of your

More information

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY CENTER ARTS EDUCATION TECHNICAL SPECIFICATIONS Page 1 of 5 LOADING ACCESS The Center for Arts Education has no loading dock and limited loading doors.

More information

Technical Specifications. Taylor Little Theater

Technical Specifications. Taylor Little Theater 501 East 38 th Street Erie, PA 16546 Technical Specifications Taylor Little Theater in Weber Hall Revised: March 12, 2013 SEATING CAPACITY 250 SEATS Handicap and wheelchair accessible TELEPHONE NUMBERS

More information

Technical Specifications

Technical Specifications Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts

More information

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616) 1 Seating Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI 49544 Phone: (616) 647-0939 Fax: (616) 647-0149 Technical Specifications As of June 2009 Total Seating Capacity 756 + 4 wheelchair spaces

More information

Technical Information

Technical Information Technical Information For more information please call Booking Agent and Manager: James Marsh 781-586-6770 General Information www.lynnauditorium.com The Lynn Memorial Auditorium is located in historic

More information

TECHNICAL SPECIFICATIONS HARVEY THEATER

TECHNICAL SPECIFICATIONS HARVEY THEATER TECHNICAL SPECIFICATIONS HARVEY THEATER Version: January 2018 Brooklyn Academy of Music Revised: January 31, 2018 30 Lafayette Ave Revised By: R. Gastelum Brooklyn NY, 11217 Phone: 718 636 4146 Fax: 718

More information

Main Stage Technical Specs - Hall #2

Main Stage Technical Specs - Hall #2 Main Stage Technical Specs - Hall #2 Proscenium: - Height:...20' (06.10m) - Width:...31' 10"(09.70m) Apron: - Depth:...4' (01.22m) - Width:...45' 6" (13.87m) - Height:...3' 7" (01.09m) Stage: - Maximum

More information

Technical Information

Technical Information 5/3/2006 1 Hamilton Place Theatre / Studio at Hamilton Place / Copps Coliseum / Hamilton Place Convention Centre Ronald V. Joyce Centre for the Performing Arts Technical Information Building with members

More information

Dr JOHN GALLAGHER CONCERT CHAMBER

Dr JOHN GALLAGHER CONCERT CHAMBER 1 TECHNICAL SPECIFICATIONS Dr JOHN GALLAGHER CONCERT CHAMBER STAGE DIMENSIONS 12.5m wide at the downstage edge tapering to 10.7m wide at the far upstage wall. 8m in depth Elevated 0.9m from main auditorium

More information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface

More information

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3 2017 Technical Specs updated: Jan 2017 Executive Director: Greg Ray Technical Director: Vonny Boarts Email: vonny@thestatetheatre.org www.thestatetheatre.org SEATING CAPACITY The State Theatre features

More information

Quick-Advance Fact Sheet

Quick-Advance Fact Sheet Quick-Advance Fact Sheet Venue Contact and Load In Information Riviera Theatre and Performing Arts Center- Capacity- Venue Mailing Address: Webster St., North Tonawanda, NY Venue Phone:.. Chuck Antolina,

More information

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER Updated: June 27, 2011 TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER TELEPHONE NUMBERS: General Administrative Offices 253.591.5890 Production Stage Manager 253.591.5898 Facsimile 253.591.2027

More information

Jane Mallet Theatre Technical Specifications

Jane Mallet Theatre Technical Specifications TECHNICAL SPECIFICATIONS Stage Technician Unions Stage I.A.T.S.E. Local 58 Stage Door Entrance Scott Street (West side of building South of Front St.) Seating Capacity Lower Orchestra 252 Cross Aisle*

More information

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018 GENERAL THEATRE INFORMATION: Stage Floor: Dance Floor: HALL: Standard Stage: Sprung hard wood, painted black. Pit area: Nivoflex adjustable risers, hardwood ply top. Pit area is not sprung. Note: Neither

More information

Concert Hall Technical Specifications

Concert Hall Technical Specifications Concert Hall Technical Specifications Revised 12-14-2017 4132 East Pecos Road Gilbert, AZ 85295 Phone: (480) 279-7190 Fax: (480) 279-7590 Website: www.higleyarts.org HCPA Overview The Higley Center for

More information

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min. TECHNICAL RIDER Company: WINTER GUESTS Performance: Simulacrum This rider should be included in the contract when the performance is booked, and any deviations must be clarified with technical manager

More information

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL. TECHNICAL INFORMATION MAIN HOUSE STAGE DIMENSIONS The main stage is a flat floor sprung hardboard stage with a proscenium opening of 10.5m x 9.1m depth. The proscenium height is variable by the house border

More information

Technical Specifications and Inventory Spring 2018

Technical Specifications and Inventory Spring 2018 African American Performing Arts Center Technical Specifications and Inventory Spring 2018 Annette Caine, Executive Director 505-222-9756 annette@aapacnm.org James Lewis, Facility Manager 505-222-0778

More information

Technical Specifications

Technical Specifications FOLLY THEATER 300 W. 12th Street Kansas City, Missouri 64105 Technical Specifications Stephanie Spatz-Ornburn, Event Manager Lee Saylor, Technical Director Business Office: (816) 842-5500 Production Office:

More information

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information WRIGHT AUDITORIUM TECHNICAL INFORMATION 1. Contact Information 2. General Information 3. Dimensional Information House Goods House Accessories Dressing Rooms (Description) 4. Lighting Information Lighting

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet Pentas 2 The Kuala Lumpur Performing Arts Centre (klpac) Updated: 15 th July 2017 Table of Contents 1. General - Stage - Back Stage / Stand-by Area - Dressing Rooms - Security 2. Staging

More information

SAINT ANSELM COLLEGE DANA CENTER

SAINT ANSELM COLLEGE DANA CENTER SAINT ANSELM COLLEGE DANA CENTER Facility Information Facility: DANA CENTER KOONZ THEATRE : on campus use lower entrance Capacity: 580 (continental seating) Office Phone: (603) 641-7710 Director: Robert

More information

Arcadia Performing Arts Center Technical Specifications and Information

Arcadia Performing Arts Center Technical Specifications and Information Arcadia Performing Arts Center Technical Specifications and Information Mailing Address: P.O. Box 661178 Arcadia, CA 91066 Physical Address: 188 Campus Dr. Arcadia, CA 91007 HOUSE CAPACITY Auditorium Seating

More information

Sandusky State Theatre Technical Specifications

Sandusky State Theatre Technical Specifications Sandusky State Theatre Technical Specifications Updated Jan 14, 2014 Tim Kostel Technical Director Sandusky State Theatre 107 Columbus Ave. Sandusky, OH 44870 419.626.1347 419.626.9835 fax tkostel@sanduskystate.com

More information

Schauer Arts and Activities Center Technical Information Touring Companies

Schauer Arts and Activities Center Technical Information Touring Companies Schauer Arts and Activities Center Technical Information Touring Companies 147 N Rural Street Revised July 2016 Hartford, WI 53027 www.schauercenter.org This document available at: www.schauercenter.org

More information

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6 Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6 The information below has been provided by the Technical Director of the Dance Centre. Please

More information

DEREHAM MEMORIAL HALL

DEREHAM MEMORIAL HALL DEREHAM MEMORIAL HALL is a multi purpose venue incorporating a 294 seat proscenium arch theatre. A standard stage, lighting and sound rig as set out below will be provided, unless otherwise agreed. Any

More information

Facility Information

Facility Information 20 Facility Information Please note: The information contained in this document is for planning purposes only and is subject to change at any time. The measurements contained herein are approximate. Please

More information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface

More information

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used. Technical Specifications: Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used. Proscenium Opening Height: 16 ft. Width: 36 ft. Drapes in, approx.

More information

VENUE TECHNICAL REQUIREMENTS

VENUE TECHNICAL REQUIREMENTS VENUE TECHNICAL REQUIREMENTS INTRODUCTION The following are minimum standards required for an Aspen Santa Fe Ballet production. Final production requirements may change based on requested ballets within

More information

Main House Technical Specifications

Main House Technical Specifications Main House Technical Specifications Technicians Senior Technician - Stephen Payne Technician - Drew White Technician - Joanne Marshall Arena Theatre Wulfruna Street Wolverhampton WV1 1SE Tel: 01902 321

More information

Technical Specification Pavilion Dance

Technical Specification Pavilion Dance Technical Specification Pavilion Dance Contact Information Position Name Email Phone Number Technical Manager Technician Neil Kingston Louise Buckton neil@pdsw.org.uk louiseb@pdsw.org.uk 01202 203630 01202

More information

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5 Lighting -Lighting control PC with Horizon software and a 24 sub master wing. 2 Universes of DMX distributed via PathPort nodes. Our standard rep plot features 2 full stage back light washs of 20 PAR 64

More information

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS Auditorium Seating The Visy Theatre is a versatile venue with many configurations. The standard venue hire includes the venue in standard mode with a capacity of 200. The table and diagram below detail

More information

Technical Specifications

Technical Specifications Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts

More information

Z SPACE Technical Specifications. Stage & Rigging

Z SPACE Technical Specifications. Stage & Rigging Stage & Rigging Stage D anser Sprung Oak Dance Floor treated with Masonite and Roscoe marley dance flooring Dimensions: 43 w x 64 d. Rep. stage layout is as follows: Rear Projection Screen (15 h x 26.5

More information

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website: Facility Name: FISHER THEATER GENERAL INFORMATION Facility Name: Mailing Address: Phone Number: E-mail Address: IOWA STATE CENTER Scheman Building Suite 102, 1805 Center Drive, Ames, IA 50011 515-294-3347

More information

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony. ANVIL CENTRE THEATRE S technologically advanced, flexible space is ideal for performing arts productions, dance recitals, music shows, digital and analog presentations, cabarets, banquets, and business

More information

Concert Hall Technical Specifications

Concert Hall Technical Specifications Concert Hall Technical Specifications Revised 11/1/2014 4132 East Pecos Road Gilbert, AZ 85295 Phone: (480) 279-7190 Fax: (480) 279-7590 Website: www.higleyarts.org HCPA Overview The Higley Center for

More information

Visy Theatre technical information and general specifications 2019

Visy Theatre technical information and general specifications 2019 Visy Theatre technical information and general specifications 2019 General Information THEATRE ACCESS Artist access to the Visy Theatre is via either the lower loading dock or through the backstage doors

More information

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information Stage Dimensions Fly System Stage Floor Proscenium Opening (fixed size) Width 11.44m (37 6 ) Height

More information

Blue Bridge Repertory Theatre Technical Specifications

Blue Bridge Repertory Theatre Technical Specifications Blue Bridge Repertory Theatre Technical Specifications Blue Bridge Repertory Theatre makes its home at the historic Roxy Theatre in Quadra Village, adjacent to Downtown Victoria. It is wheelchair-accessible,

More information

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston Studio Theatre Technical Specifications Theatre Manager Kim Scarlata 209.831.6205 Box Office Coordinator Laura Johnston 209.831.6208 Theatre Operations & Technical Assistant Matthew Morgan 209.831.6275

More information

Centre Stage and City Room at Surrey City Hall Venue Information

Centre Stage and City Room at Surrey City Hall Venue Information Centre Stage and City Room at Surrey City Hall Venue Information This document will help ensure that your event is as successful as possible. If your questions aren t answered here contact Neil Scott,

More information

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET ARTPARK MAINSTAGE THEATER TECHNICAL PACKET LOCATION: 450 South 4 th Street, Lewiston, NY 14092 CONTACT: Sonia Kozlova Clark, Executive Director: sclark@artpark.net 716-754-9000 x 117 Susan Stimson, Production

More information

Ferst Center for the Arts Technical Specifications (Revised May 2016)

Ferst Center for the Arts Technical Specifications (Revised May 2016) Ferst Center for the Arts Technical Specifications (Revised May 2016) Office of the Arts Georgia Tech 349 Ferst Drive NW Atlanta, GA 30332-0468 404-894-9601 Box Office 404-894-2787 Administrative Office

More information

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422 T1 National Theater Total Seating Capacity: 1714 + 10 wheelchair spaces Total Orchestra Pit seats: 93 Orchestra Pit Section 1: 44 Orchestra Pit Section 2: 49 Auditorium (Basement 1): 324 Under Balcony

More information

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway INCOMPLETE AS OF 09-04-2017 DRAFT PURPOSES ONLY 1 of 13 Contents Contents Pg 2 Address Pg 3 Staff Pg 3 Telephone

More information

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre TECHNICAL INFORMATION HAYMARKET THEATRE VIRGINIA TECH CAMPUS Blacksburg, Virginia Office: 540-231-3499 Email: production@vt.edu Version Date: January 25, 2018 Virginia Tech does not discriminate against

More information

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR Lane Community College Performance Hall 4000 E. 30 th Eugene, OR. 97405 Technical: (541) 463-5643 Office: (541) 463-3108 Fax (541)463-4172 I. Information Direct all technical questions to James McConkey,

More information

CENTRE FOR PERFORMING ARTS

CENTRE FOR PERFORMING ARTS CENTRE FOR PERFORMING ARTS Venue, Facilities & Equipment CPA VENUE AREA SIZE FUNCTION Dressing Room (Female) 6 x 12m Dress and makeup room with attached toilet and shower facilities Dressing Room (Male)

More information

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts Blaisdell Hall. 300 Campus Drive. Bradford PA. 16701 1 Table of Contents: General Information...Pg 2 KOA/Speer Lobby..Pg 3 KOA Art

More information

The Breen Center for the Performing Arts Saint Ignatius High School

The Breen Center for the Performing Arts Saint Ignatius High School The Breen Center for the Performing Arts Saint Ignatius High School RENTAL INFORMATION, POLICIES AND SETUP DETAILS Performance space: The Proscenium is 48-0 wide and 25-0 high. There are two proscenium

More information

Dale F. Halton Theater Technical Specifications

Dale F. Halton Theater Technical Specifications Dale F. Halton Theater Technical Specifications Mailing Address Dale F. Halton Theater Overcash Performing Arts Center Central Piedmont Community College P. O. Box 35009 Charlotte, North Carolina 28235-5009

More information

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO. Updated on Monday, 29 January 2018 Get In 1) Via Small Goods lift (Street Level) dimensions 1.10m (W) x 1.10m (L) x 2.10m (H) 2) Via Goods lift dimensions 2.5m (W) x 4.0m (L) x 3.0m (H) and along a corridor

More information

Technical Specifications

Technical Specifications Technical Specifications 3865 North Wickham Road Melbourne, Florida 32935 Main Office (321) 433-5719 Ticket Office (321) 242-2219 Rob Adams Technical Operations Director (321) 433-5822 adamsro@easternflorida.edu

More information

Technical Specification (Studio Theatre)

Technical Specification (Studio Theatre) Technical Specification (Studio Theatre) TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of Under the Management of Theater Location 315 West Broadway Louisville, Kentucky 40202-2105 THEATRE STAFF Vice President of Operations: Chuck Schmidt (502) 566-5113 Facility Rental: Brandy Leitner (502)

More information

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS STAGE DIMENSIONS Apron to Back Wall Columns 31 6 Apron to Back Wall 33 5 Curtain Line to Back Wall Columns 23 9 Curtain Line to Back Wall 25 8 Curtain

More information

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013 Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013 27 West Main Street Norwich, NY 13815 www.chenangoarts.org 607-336-2787 Table of Contents AUDITORIUM... 2 STAGE... 2 RIGGING...

More information

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115 Egyptian Theatre 135 N. Second Street DeKalb, Illinois 60115 Telephone: (815) 758-1215 Box Office: (815) 758-1225 Fax: (815) 748-3292 Owned & Operated by: Preservation of Egyptian Theatre (P.E.T.) a 501(c)(3)

More information

Stage. Get In & Parking

Stage. Get In & Parking Stage Capacity Stage Rigging Masking Auditorium 230 seats or 216 seats if front row removed. Wheelchair positions front row and upper auditorium right. Raked seating upper & lower house. 9.45m wide x 6.9m

More information

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black) AUDITORIUM PERFORMANCE AREA Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black) Standard (with THRUST seating) 6.1m Wide

More information

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015 THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015 CONTACTS Matt Schliesman, Executive Director 913 South 8 th Street Email: matts@cccshows.org Peggy A.

More information

The ACT Facility Technical Specifications Main Stage Information

The ACT Facility Technical Specifications Main Stage Information 1 The ACT Facility Technical Specifications Main Stage Information Stage: Proscenium Height - 25 Proscenium Width - 40 Grid Height 55 In front of main drape to curved apron furthest edge - 12 6 Curved

More information

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way Theatre Specifications Toombs Auditorium Address: 3001 East First St. Vidalia GA 30474 Julie Busby, Auditorium Manager Phone: 912-538-3135 Fax: 912-538-3164 E-mail: jbusby@southeasterntech.edu Seating

More information

New Theatre Royal Lincoln Technical Information

New Theatre Royal Lincoln Technical Information 1 New Theatre Royal Lincoln Technical Information Please note that some items on our tech spec are subject to a recharge. Please contact Steve Chambers the Technical Manager on 07985 275522 or email technical@newtheatreroyallincoln.com

More information

RPAC REDLANDS PERFORMING ARTS CENTRE

RPAC REDLANDS PERFORMING ARTS CENTRE RPAC REDLANDS PERFORMING ARTS CENTRE CONCERT HALL Technical Specifications STAGE FACILITIES Soft Proscenium Theatre mode (see stage masking) Concert Platform (open area with acoustic walls on PS, OP and

More information

Technical Specifications Updated 01/10/2017. Stage

Technical Specifications Updated 01/10/2017. Stage Stage Capacity Setting Line Stage Please see your contract for capacity. Setting line(s) is 1.35m from the step of row A of the seating bank or 1.35 from the onstage edge of seats. All fire paths should

More information

Latrobe Performing Arts Centre

Latrobe Performing Arts Centre Latrobe Performing Arts Centre Traralgon Town Hall Technical Specifications Updated 24/5/07 Technical Manager: Phone number: 03 5176 3426 Mobile Number: 0428 378 121 Fax number: 03 5176 3426 Email address:

More information

The Bailey Theatre Technical Data

The Bailey Theatre Technical Data The Bailey Theatre Technical Data The Bailey Theatre is a 100-year old vaudeville theatre that has been renovated and upgraded to a modern, multipurpose, live performance venue. Construction was completed

More information

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM Auditorium Technical Specifications 1. Seating *fixed seating for 1508 *16 additional handicap access spaces 2. Stage

More information

Matt Dann Cultural Centre

Matt Dann Cultural Centre Matt Dann Cultural Centre Matt Dann Theatre Technical Specifications 13/07/09 Technical Manager: Brad Holder Phone number: 08 9158 9369 Mobile Number: 0447 632 936 Fax number: 08 9172 2472 Email address:

More information