Remote-Field Examination Using Array Sensors
|
|
- Nickolas Hines
- 6 years ago
- Views:
Transcription
1 ECT This image cannot currently be displayed. Remote-Field Examination Using Sensors Presented by: Brian K. Beresford TechCorr &. Manager Tubular Integrity Services Presented at: The International Chemical and Petroleum Industry Technology (ICPIIT) X Conference in Houston, Texas, June 2007.
2 Acknowledgements Dennis O'Quinn Chevron, Cedar Bayou, Texas Max Kidd Equistar Chemical, Channelview, Texas Will Rettman Petro Canada Oil & Gas Fort McMurray, Alberta ECT
3 Overview Introduction Analysis Technique Detection Method Remote Field Bobbin Probe Technology Disadvantages Remote Field Probe Technology Advantages Chevron Vs. Bobbin Test Bundle Results Vs. Bobbin Equistar C-Scan Results Petro Canada Oil & Gas Vs. Bobbin Results Conclusions ECT
4 Introduction This paper presents the results from a remote field array examination and demonstration of SA-214, ¾ X.072 exchanger tubing. The exchanger was found to be fouled due to product build-up. Tube cleanliness was a concern and two cleaning methods were employed to compare the effects of the acquisition and analysis of the data. All tubes were examined with a remote field bobbin probe and an array probe to compare the averaging effect of the bobbin. ECT
5 Introduction (Cont d) Tubes sections from the same exchanger had been found to have leaked or corroded in the past and the failure mechanisms had been attributed to multiple inside diameter pitting located in the same circumference of the tube. TechCorr developed a remote field eddy current array inspection and analysis procedure for detecting and sizing corrosion pits on the internal surface. ECT
6 Analysis Technique The remote field eddy current array sensitivity was required to detect multiple inside diameter pits in the same circumference using a voltage curve for multiple pitting and a phase curve for single pitting. The probe chosen was a remote field eddy current array probe built by Carbon Steel. Carbon Steel s EZ- analysis software played a big part in the ease (EZ) in which the speed of the analysis was done. This was accomplished by employing the Auto Normalization buttons. This analysis was tried with other competitors software and was found to take 3-4 times longer to complete the analysis. ECT
7 Detection Method With considerations of the material and the size of the tube as well as the type of the defects to be inspected, an remote field eddy current inspection technique was considered to be the best choice. IRIS was tried with no success even after water blasting eight (8) tubes and grit blasting six (6) tubes. ECT
8 Remote Field Bobbin Technology Probe Disadvantages Averages over the circumference 360 Vector addition of multiple defects Limited to no defect morphology circumferential extent ECT
9 Remote Field Probe Technology Advantages Segmented coils decreases affects of averaging Increased signal to noise ratio Limits vector addition of multiple defects Provides more detailed information on defect morphology ECT
10 Remote Field Probe C-scan Technology A C-Scan Presentation of the data is now possible using the array probe technology. This presentation is extremely useful during the analysis phases of the programs. Metal loss can be attributed to specific quadrants within the tube being inspected. The below image shows metal wall loss in the third quadrant, where as the other sections of the tube are near nominal. ECT
11 Chevron VS Bobbin There was a difference between the bobbin and array percent wall loss. The array data appears to be more accurate in sizing small volume pitting compared to the bobbin data based on the pulled tube results. The tube was then longitudinally split in half and the internal surface cleaned using a wire brush for examination of the internal surface. ECT
12 Chevron Results Tube cleanliness was a concern only for the water blast tubes. The Grit blast tubes produced better RFT data. Less noise. ECT
13 Chevron Defect Bar Chart ECT
14 Chevron Bobbin Defect Bar Chart As per the pulled tube results bobbin data overcalled the pitting depth. ECT
15 VS Bobbin in Test Bundle Raw data from a specific tube was released to TechCorr from a customers test bundle to show the sensitivity and accuracy of technology. The tube specifications were SA-214, ¾ X.109 exchanger tubing. This tube had a large volume 360º flaw, a 180º flaw and a small pin hole drilled in the tube. The bobbin data from the test bundle revealed that the pin hole was so small in volume and because of the averaging affect the pin hole only revealed a 34% wall 137º. The array data revealed that the pin hole in the test bundle matched the TWH in the calibration standard. As revealed in the array defect printout below its much easier to identify the defect mythology. ECT
16 Bobbin Test Bundle Result The bobbin data revealed a 137º 34% wall loss (The TWH in calibration standard 90º) ECT
17 Test Bundle Result The array data revealed a 112º on coil #5 100% wall loss (The TWH in calibration standard 112º) 100% TWH (Pin Hole) 360º Flaw all 6 coils hit TWH 180º Flaw 3 coils hit ECT
18 Test Bundle Calibration Standard ¾ X The calibration standard 112º and the 20% 155º TWH ECT
19 Equistar Exchanger Results Equistar requested that TehhCorr perform a reexamination on a specific exchanger that was examined by another company to compare the sensitivity and accuracy of technology. The tube specifications were SA-214, ¾ X.083, 20 feet in length. The array examination revealed mostly outside diameter 360º corrosion and some isolated pitting. The bobbin data and array data were compared and it concluded that the array data was more accurate than the bobbin data. The pin hole was so small in volume and because of the averaging affect the pin hole only revealed a 34% wall 137º. The defects were visually noticeable. As revealed in the array defect printout below its much easier to identify the defect morphology. ECT
20 Pitting & Corrosion Defect Distribution Map ECT
21 Side View Drawing of Exchanger Showing Damage Location ECT
22 Equistar of SA-214 ¾ x.083 C-Scan Voltage Curve ECT
23 Equistar Calibration Standard 100% Thru Wall Hole 60% Single Flat Bottom Hole 20% Outside Diameter Groove ECT 60% 270º Fret
24 Equistar Calibration Standard Continued ECT 360º Tapered Flaw
25 E-3706-A Exchanger 360º Corrosion Stationary End Floating End ECT Notice all 6 channels hitting and the response from the C-scan Plot
26 Petro Canada Oil & Gas of Exchanger E-112. Vs. Bobbin Petro Canada requested TechCorr to examine 100% of their exchanger utilizing remote field eddy current utilizing and Bobbin probes. The tube material specification was ¾ x.083 SA-214. The array in this case was more sensitive to pitting located on the near and far side of the tube support. After the initial calibration setup we than rotated the tube support horizontal. By rotating the tube support horizontal it makes strip chart review easier. ECT
27 Petro Canada Oil & Gas Vs. Bobbin Defect Count Bobbin Probe Inspected 129 Tubes Total Defects 97 Probe Inspected 129 Tubes Total Defects 240 ECT
28 Row 27 Tube 1 (100% Through Wall Hole) The array probe Row 27 Tube 1 Through Wall Hole ECT
29 Vs. Bobbin Indication Defect on back side of tube support Percent wall loss with 32% ECT Defect on back side of tube support Percent wall loss with Bobbin 4%
30 Conclusions technology is more sensitive and accurate than bobbin. More sensitive to defects near tube supports. Utilizing the proper software increase the speed of the analysis. Auto normalization is a key ingredient to the analysis. provides more detailed information on defect morphology Segmented coils decreases affects of averaging ECT
31 ECT For Additional Information Please Visit Our Website
MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire
MultiMac SM Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Features of the MultiMac SM Electronics Simultaneous Coil and/or Rotary Probe operation Differential
More informationMultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire
MultiMac Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Inspection Features Versatile Threshold Selection Challenging test conditions are made simple
More informationSteam Generator Tube Inspection I
Steam Generator Tube Inspection I Development of Smart Array Probe and Introduction of New Inspection System K. Maeda, J. Shimone, A. Nunoko, J. Akagawa, Y. Nagata, H. Izumida, Y. Harada, Nuclear Engineering,
More informationRG NDT INTERNATIONAL INC. Drill Pipe and Tubing Inspection System
RG NDT INTERNATIONAL INC Computerized Drill Pipe Manual 165 Oates Road Houston, Texas 77013 Phone: 713-673-5928 Fax: 713-673-5957 ELECTRONIC DRILL PIPE DESK MOTORIZED BUGGY DRIVE HEAD 2 Table of Contents
More informationThe Use of the Balanced Field Electromagnetic. Technique to Size Corrosion Fatigue Cracking in. Boiler Tubes
STATE OF THE ART PRODUCTS & SERVICES FOR NON-DESTRUCTIVE TESTING The Use of the Balanced Field Electromagnetic Technique to Size Corrosion Fatigue Cracking in Boiler Tubes AUTHOR: REPORT #: SHAWN GOWATSKI
More informationRG NDT INTERNATIONAL INC
RG NDT INTERNATIONAL INC User Manual 165 Oates Road Houston, Texas 77013 Phone: 713-673-5928 Fax: 713-673-5957 GENERAL OVERVIEW Features two (2) inline inspection stations for the detection of: 1. Transverse
More informationAPPLICATION OF PHASED ARRAY ULTRASONIC TEST EQUIPMENT TO THE QUALIFICATION OF RAILWAY COMPONENTS
APPLICATION OF PHASED ARRAY ULTRASONIC TEST EQUIPMENT TO THE QUALIFICATION OF RAILWAY COMPONENTS K C Arcus J Cookson P J Mutton SUMMARY Phased array ultrasonic testing is becoming common in a wide range
More informationCiva Modelling for Internal Ultrasonic Tube Testing
Civa Modelling for Internal Ultrasonic Tube Testing More info about this article: http://www.ndt.net/?id=22360 Ed Ginzel 1 1 Materials Research Institute, Waterloo, Ontario, Canada e-mail: eginzel@mri.on.ca
More informationINTRODUCTION. The sketch above shows the initial concept for the HRSG Internal Access Tool. 535 Old Frankstown Road Pittsburgh, PA
INTRODUCTION Most Heat Recovery Steam Generators (HRSGs) are not designed to allow access to the majority of the finned tubes for inspection. These tubes are spaced tightly together and are welded to headers.
More informationA COMPUTERIZED SYSTEM FOR THE ADVANCED INSPECTION OF REACTOR VESSEL STUDS AND NUTS BY COMBINED MULTI-FREQUENCY EDDY CURRENT AND ULTRASONIC TECHNIQUE
More Info at Open Access Database www.ndt.net/?id=18566 A COMPUTERIZED SYSTEM FOR THE ADVANCED INSPECTION OF REACTOR VESSEL STUDS AND NUTS BY COMBINED MULTI-FREQUENCY EDDY CURRENT AND ULTRASONIC TECHNIQUE
More informationHRSG FINNED TUBE STUDY USING THE LOW FREQUENCY ELECTROMAGNETIC TECHNIQUE TO EXAMINE TUBES FROM THE OUTSIDE DIAMETER TESTEX, INC.
Report#: SPG11-01-14 STATE OF THE ART PRODUCTS & SERVICES FOR NON-DESTRUCTIVE TESTING HRSG FINNED TUBE STUDY USING THE LOW FREQUENCY ELECTROMAGNETIC TECHNIQUE TO EXAMINE TUBES FROM THE OUTSIDE DIAMETER
More informationUltrasonic Testing adapts to meet the needs of the Automotive Tube Industry
Ultrasonic Testing adapts to meet the needs of the Automotive Tube Industry By Mark Palynchuk, Western Instruments Inc. Mill-Line Ultrasonic Testing (UT) has typically been limited to wall thicknesses
More informationPractical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing
ECNDT 2006 - Th.1.1.4 Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing R.H. PAWELLETZ, E. EUFRASIO, Vallourec & Mannesmann do Brazil, Belo Horizonte,
More informationPRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING
PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING R.H. Pawelletz, E. Eufrasio, Vallourec & Mannesmann do Brazil, Belo Horizonte, Brazil; B. M. Bisiaux,
More informationCIRCOGRAPH. Non-Destructive Eddy Current Testing of Long Products such as Wires, Bars and Tubes
CIRCOGRAPH Non-Destructive Eddy Current Testing of Long Products such as Wires, Bars and Tubes FOERSTER DIVISION TEST SYSTEMS (TS) The Company FOERSTER is a global technology leader for nondestructive
More informationEDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION
EDDY CURRENT MAGE PROCESSNG FOR CRACK SZE CHARACTERZATON R.O. McCary General Electric Co., Corporate Research and Development P. 0. Box 8 Schenectady, N. Y. 12309 NTRODUCTON Estimation of crack length
More informationEDDYCHEK 5. Innovative eddy current testing for quality and process control. Touchscreen. Networking. All major applications.
EDDYCHEK 5 Innovative eddy current testing for quality and process control All major applications 2 channel testing Touchscreen Reporting Networking Eddy current testing: essential Full-body testing with
More informationProgressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )
Progressive Scan CCD Color Camera KP-FD30M Specifications ( Revision.1 ) Sep 10, 2004 1. General The KP-FD30M is a single CCD type RGB color camera which utilized the progressive scan CCD image sensor
More informationSC26 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields
More informationNDT Supply.com P.O. BOX 7350 Shawnee Mission, KS USA
NDT Technologies, Inc. Wire Rope Inspection Using proven MFL Technology. NDT Technologies has over 30 years of experience dedicated to developing and improving Wire Rope Inspection equipment and methods.
More informationi-pcgrid Workshop 2018
i-pcgrid Workshop 2018 Power Line Carrier Holes and Field Trial Tests Presented by: Tony Bell PLC Product Manager AMETEK Power Instruments Pulsar Products www.ametekpower.com 1 DEFINITION of Carrier Holes
More informationSIMET AVIKO D INSTRUCTION MANUAL SORTING Solutions, Ltd.
SIMET AVIKO D INSTRUCTION MANUAL 1870 SORTING Solutions, Ltd. 1. TABLE OF CONTENTS 1. TABLE OF CONTENTS...1 2. INTRODUCTION...2 2.1. Application...2 2.2. Operating Conditions...2 2.3. Electro - Optical
More informationLecture 18 Design For Test (DFT)
Lecture 18 Design For Test (DFT) Xuan Silvia Zhang Washington University in St. Louis http://classes.engineering.wustl.edu/ese461/ ASIC Test Two Stages Wafer test, one die at a time, using probe card production
More informationStart Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:
If there is a short circuit in the cable, it will display as follows: Push key (No) to exit calibration function. Push key (Yes) to repeat measurement process. 11 Note: The calibration will recover the
More informationApplication Note AN-708 Vibration Measurements with the Vibration Synchronization Module
Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module Introduction The vibration module allows complete analysis of cyclical events using low-speed cameras. This is accomplished
More informationIntelligent Pendulum Hardness Tester BEVS 1306 User Manual
Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1 Content 1. Company Profile... 3 2. Product Introduction... 3 3. Operation Instruction...
More informationCover Sheet. Scanning Report of Flexible Riser Pipe Section EVI /7/2005. Inspection Report
Cover Sheet Document Number EVI-2005-0002 Document Date 7/7/2005 Document Title Customer -other- AEA Technologies Type Inspection Report Prepared by: Date: Reviewed by: Date: Approved by: Date: Evisive,
More informationNDT Supply.com 7952 Nieman Road Lenexa, KS USA
ETher ETherCheck Combined Eddy Current & Bond Testing Flaw Detector The ETherCheck is a combined Eddy Current and Bond Testing Flaw Detector which comes with a rich range of features offered by a best
More informationSuper Idea for Ultrasonic Inspection
Super Idea for Ultrasonic Inspection Ultrasound Inspection Ultrasound phased array (PA) and Time Of Flight Diffraction (TOFD), two of the new NDT technologies, have become one important development trend
More informationNew appraoch for X-ray weld inspection of pipeline segments
New appraoch for X-ray weld inspection of pipeline segments Lennart Schulenburg VisiConsult X-ray Systems & Solutions GmbH 1 Overview Weld inspection in heavy industries ( Pipe and Tank ) Analogue Film
More informationQuick Start. RSHS1000 Series Handheld Digital Oscilloscope
Quick Start RSHS1000 Series Handheld Digital Oscilloscope General Safety Summary Carefully read the following safety precautions to avoid personal injury and prevent damage to the instrument or any products
More informationBitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.
BitWise. Instructions for New Features in ToF-AMS DAQ V2.1 Prepared by Joel Kimmel University of Colorado at Boulder & Aerodyne Research Inc. Last Revised 15-Jun-07 BitWise (V2.1 and later) includes features
More informationMSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer
Link Instruments Innovative Test & Measurement solutions since 1986 Store Support Oscilloscopes Logic Analyzers Pattern Generators Accessories MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer $ The
More informationMEC -Pipe Crawler FLEXIBLE RISER INSPECTION REPORT
MEC -Pipe Crawler FLEXIBLE RISER INSPECTION REPORT Client: Client a Facility: Site FPU Items Inspected: 13 Flexible Riser Inspection Method: MEC -FIT technology Commencement Date: 11 th September 2015
More informationManipulator Technical Specification Welding/Cutting expert
Manipulator Technical Specification Welding/Cutting expert www.timewelder.com 0 Welding Manipulator Product introduction Welding manipulator is divided into standard (TZ), heavy duty (TZH) types, suitable
More informationSecrets of the Studio. TELEVISION CAMERAS Technology and Practise Part 1 Chris Phillips
Secrets of the Studio TELEVISION CAMERAS Technology and Practise Part 1 Chris Phillips Television Cameras Origins in Film Television Principles Camera Technology Studio Line-up Developments Questions of
More informationA449-6S 70 CENTIMETER FM YAGI ANTENNA MHz
ASSEMBLY AND INSTALLATION A449-6S 70 CENTIMETER FM YAGI ANTENNA 440-450 MHz COMMUNICATIONS ANTENNAS 951425 (7/93) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN
More informationWheelProbe2. Simplicity Capability Reliability
WheelProbe2 Simplicity Capability Reliability From the innovators who brought the idea to the market over a decade ago, Sonatest is proud to extend its WheelProbe family by introducing the New Generation
More informationORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA
BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps
More informationWheelProbe 2. Innovation, Flexibility, Performance
WheelProbe 2 Innovation, Flexibility, Performance Composite inspection WP2 allows you to build the most efficient solutions for scanning large areas of composite. As the best alternative to immersion inspection
More informationMTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement
A worldwide leader in precision measurement solutions MTI-2100 FOTONIC SENSOR High resolution, non-contact measurement of vibration and displacement MTI-2100 Fotonic TM Sensor Unmatched Resolution and
More information800 Displaying Series Flowmeter
TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially
More informationPracticum 3, Fall 2010
A. F. Miller 2010 T1 Measurement 1 Practicum 3, Fall 2010 Measuring the longitudinal relaxation time: T1. Strychnine, dissolved CDCl3 The T1 is the characteristic time of relaxation of Z magnetization
More informationMAKE AN RGB CONTROL KNOB.
MAKE AN RGB CONTROL KNOB. This is a knob based colour changing controller that uses a custom programmed microcontroller to pack a lot of features into a small affordable kit. The module can drive up to
More informationThe Measurement Tools and What They Do
2 The Measurement Tools The Measurement Tools and What They Do JITTERWIZARD The JitterWizard is a unique capability of the JitterPro package that performs the requisite scope setup chores while simplifying
More informationThe NorCal SMT Dummy Load Assembly and Operating Manual Rev. 1.0 January 4, 2005
The NorCal SMT Dummy Load Assembly and Operating Manual Rev. 1.0 January 4, 2005 Copyright 2005 W3CD 1 1. Introduction The NorCal SMT Dummy Load is a practice kit for anyone wishing to gain some experience
More informationMinimize your cost for Phased Array & TOFD
Minimize your cost for Phased Array & TOFD Latest ultrasonic flaw detector from SIUI, incorporates the latest advancements in Encoder In/Out UT/ TOFD Probe high-performance Phased Array and TOFD detection
More informationmass flow meter for Gases
User Manual deltaflowc mass flow meter for Gases 1 1. Welcome to systec Controls Thank you very much for using deltaflowc. deltaflowc is a state-of-the art mass flow meter for gases. This user manual guides
More informationSC24 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface
More informationProduct Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes
Product Manual MNX10015 / REV C MODEL SB142, SB242 Dual Output Series Switch Boxes Contents Section I Overview Introduction.... 2 Description... 2 Section II Installation Mounting... 3 Electrical Connections...
More informationSection C Recorders. DPR mm Digital Strip Chart Recorder
91-00-01-01 Section C Recorders Contents Product Type Literature No. Overview 40-00-02-02 LeaderLine PC Software 51-52-03-16 SCF Software Configuration Tool 51-52-03-26 SDA Software Data Analysis Tool
More informationLMA-300 TRIPPLE-FUNCTION WIRE ROPE INSPECTION SYSTEM Including CC-04-USB Signal Console. Operation and Maintenance Manual
LMA-300 TRIPPLE-FUNCTION WIRE ROPE INSPECTION SYSTEM Including CC-04-USB Signal Console Operation and Maintenance Manual WARRANTY: NDT Technologies, Inc. warrants products manufactured by NDT Technologies,
More informationColour Explosion Proof Video Camera USER MANUAL VID-C
Colour Explosion Proof Video Camera USER MANUAL VID-C Part Number: MAN-0036-00 Rev 4 Copyright 2002 Net Safety Monitoring Inc. Printed in Canada This manual is provided for informational purposes only.
More informationEddy Current Technology. eddyliner. digital
Eddy Current Technology eddyliner Digital eddy current test instrument for one channel nondestructive testing of metal components, mass produced parts and semi-finished products according to the Preventive
More informationManual. USP-mini. icroflown Technologies. Address: PO Box CE Arnhem The Netherlands Charting sound fields
icroflown Technologies Charting sound fields USP-mini Manual MFPA-V1.0 2014-11 Address: PO Box 2205 6802 CE Arnhem The Netherlands info@microflown.com Microflown Technologies Manual USP mini Page 2 of
More informationSC24 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface
More informationLaboratory 11. Required Components: Objectives. Introduction. Digital Displays and Logic (modified from lab text by Alciatore)
Laboratory 11 Digital Displays and Logic (modified from lab text by Alciatore) Required Components: 2x lk resistors 1x 10M resistor 3x 0.1 F capacitor 1x 555 timer 1x 7490 decade counter 1x 7447 BCD to
More informationQuality Control. Chapter 23
Chapter 23 Quality Control LEARNING OBJECTIVES After studying this chapter, students will be able to: Explain the need for quality control. Point out the difference between the two basic quality control
More informationINSTRUMENT CATHODE-RAY TUBE
Instrument cathode-ray tube D14-363GY/123 INSTRUMENT CATHODE-RAY TUBE mono accelerator 14 cm diagonal rectangular flat face internal graticule low power quick heating cathode high brightness, long-life
More informationStructural Diagnostics, Inc. Leaders In Automated Ultrasonic Testing. Immersion Tanks Large Gantries Custom Systems
sdi Structural Diagnostics, Inc. sdi Leaders In Automated Ultrasonic Testing Immersion Tanks Large Gantries Custom Systems SDI-MasterScan Motion Control and WinScan Analysis The SDI MasterScan/WinScan
More informationIllumination Challenges in Non- Industrial Vision Applications. Simon Stanley Managing Director ProPhotonix IRL Ltd
Illumination Challenges in Non- Industrial Vision Applications Simon Stanley Managing Director ProPhotonix IRL Ltd ProPhotonix designs and manufactures high-quality LED systems and laser modules for the
More informationEDDYCHEK 5 Innovative eddy current testing for quality and process control
EDDYCHEK 5 Innovative eddy current testing for quality and process control All major applications 2 channel testing Touchscreen Reporting Networking Eddy current testing essential quality assurance Full-body
More informationSCALE & WEIGHT DISPLAYS
The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 102 2010 Cable Retention Force Testing of Trunk & Distribution Connectors NOTICE The Society of Cable Telecommunications
More information4 MHz Lock-In Amplifier
4 MHz Lock-In Amplifier SR865A 4 MHz dual phase lock-in amplifier SR865A 4 MHz Lock-In Amplifier 1 mhz to 4 MHz frequency range Low-noise current and voltage inputs Touchscreen data display - large numeric
More informationMinimize your cost for Phased Array & TOFD
Minimize your cost for Phased Array & TOFD Latest ultrasonic flaw detector from SIUI, SyncScan incorporates the latest advancements in high-performance Phased Array and TOFD detection into one compact
More informationReport. Report number: 1 Page 1 of 19
Page 1 of 19 Report Issue Date: September 12 2010 10:33:22 Session name: Case Study 1 Date of inspection: Inspection site: End customer: Company performing inspection: Description of inspection: Inspected
More informationRx antennas at IV3PRK: the 4-Square Rx Vertical Array
Rx antennas at IV3PRK: the 4-Square Rx Vertical Array Part 1: EZNEC modeling and the array design by Pierluigi Luis Mansutti IV3PRK After long studies and modelling with Flags and Pennants phasing, followed
More informationCapstone Experiment Setups & Procedures PHYS 1111L/2211L
Capstone Experiment Setups & Procedures PHYS 1111L/2211L Picket Fence 1. Plug the photogate into port 1 of DIGITAL INPUTS on the 850 interface box. Setup icon. the 850 box. Click on the port 1 plug in
More informationUSER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0
by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information
More informationPogoStick and Research Pogo App Operator s Guide
PogoStick and Research Pogo App Operator s Guide Research POGO App Overview Getting Started with the Research POGO App When you first start the Research POGO App, you will be asked to log into your Precision
More informationTWO BUNCHES WITH NS-SEPARATION WITH LCLS*
TWO BUNCHES WITH NS-SEPARATION WITH LCLS* F.-J. Decker, S. Gilevich, Z. Huang, H. Loos, A. Marinelli, C.A. Stan, J.L. Turner, Z. van Hoover, S. Vetter, SLAC, Menlo Park, CA 94025, USA Abstract The Linac
More informationCALIBRATION OF SOLUTION SECONDARY CURRENT FOR 9180 controls with SC software PAGE 1 OF 5
CALIBRATION OF SECONDARY CURRENT PAGE 1 OF 5 Your control has been factory calibrated to match a Unitrol standard. Unfortunately there is no practical U.S. standard for calibration of nonsinusoidal AC
More informationUpflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace
Product Data Upflow/ Horizontal Left/Right, Downflow Two Condensing Gas Fired Furnace Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA S9V2B060U3PSAA S9V2B060U4PSAA S9V2B080U3PSAA
More informationRPV and Primary Circuit Inspection. Pressure Vessel Inspection Codes for phased Arrays M. Moles, Olympus NDT, Canada
RPV and Primary Circuit Inspection Pressure Vessel Inspection Codes for phased Arrays M. Moles, Olympus NDT, Canada ABSTRACT Pressure vessel and piping welds require inspection to code worldwide to minimize
More informationMEGALEX Carbon fiber sucker rods 4/25/2011 1
4/25/2011 1 Presenter MEGALEX Mitchell Hale, P.E. Professional Professional Engineer, California US Patent #4869322 Sequential Hydraulic Fracturing of a Subsurface Formation 1989 Education BS Petroleum
More information5.1 + Stereo Monitor Controller
Broadcast Devices, Inc. Technical Reference Manual 5.1 + Stereo Monitor Controller Broadcast Devices, Inc. 2066 E. Main Street Cortlandt Manor, NY 10567 Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide
More informationMulti-Frame Matrix Capture Common File Format (MFMC- CFF) Requirements Capture
University of Bristol NDT Laboratory Multi-Frame Matrix Capture Common File Format (MFMC- CFF) Requirements Capture Martin Mienczakowski, September 2014 OVERVIEW A project has been launched at the University
More informationARS x4 MATRIX SWITCHER Instruction Manual
ARS-8400 8x4 MATRIX SWITCHER Instruction Manual Thank you for purchasing one of our products. Please read this manual before using this product. When using this product, always follow the instructions
More informationContents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4
LANsmart Pro user manual Introduction LANsmart Pro is a hand-held, multifunction Cable Map Tester and Cable Length Meter. It has an integrated Analog and Digital Tone Generator, Port Finder, and Quick
More informationAPPLICATION NOTE. Practical Tips for Using Metalic Time Domain Reflectometers (The EZ Way) What is a Time Domain Reflectometer?
a publication of R MEETING YOUR TESTING NEEDS TODAY AND TOMORROW Publication Number TTS3-0901 APPLICATION NOTE Practical Tips for Using Metalic Time Domain Reflectometers (The EZ Way) What is a Time Domain
More informationINSTALLATION MANUAL FOR THE TIMING LIGHT
INSTALLATION MANUAL FOR THE TIMING LIGHT May 12 2014 SPORTS SPLIT STEP 12566 LAZY ACRES CRT NEVADA CITY, CA 95959 www.sports-split-step.com vicborg70@gmail.com 530-272-7345 1 1. The installation of the
More informationAxle Assembly Poke-Yoke
Indiana University Purdue University Fort Wayne Opus: Research & Creativity at IPFW Manufacturing & Construction Engineering Technology and Interior Design Senior Design Projects School of Engineering,
More informationAdapter Selection. Entry Size (Continued) Table E. Multiplication. factors for wire bundles. with Equal Size Wires. This table provides multiplication
Table E. Multiplication Factors for Wire Bundles with Equal Size Wires This table provides multiplication factors for wire bundles of to 6 wires. To determine the approximate diameter of a wire bundle
More informationApplication Note Using Buffered Outputs and Patch Panels with the SETPOINT Machinery Protection System
Application Note Using Buffered Outputs and Patch Panels with the SETPOINT Machinery Protection System Doc 1446106 Page 1 of 8 Overview The SETPOINT Machinery Protection System provides three separate
More informationTech Note: How to measure additive phase noise of amplifiers using the 7000 Series
Berkeley Nucleonics Corporation Tech Note: How to measure additive phase noise of amplifiers using the 7000 Series Additive phase noise, also known as residual phase noise, is the self phase noise of a
More informationTesting and Characterization of the MPA Pixel Readout ASIC for the Upgrade of the CMS Outer Tracker at the High Luminosity LHC
Testing and Characterization of the MPA Pixel Readout ASIC for the Upgrade of the CMS Outer Tracker at the High Luminosity LHC Dena Giovinazzo University of California, Santa Cruz Supervisors: Davide Ceresa
More informationColor mixing or White-light LED (Light Emitting Diode) ERS-style product
WHT Color mixing or White-light LED (Light Emitting Diode) ERS-style product GENERAL PHYSICAL A. The product shall be an Ovation E-910FC as manufactured by Chauvet & Sons, LLC or approved equal. 1. The
More informationOPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)
user instructions 711 HULMAN STREET PO BOX 2128 TERRE HAUTE, IN 47802 812-235-6167 FAX 812-234-6975 OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES) Models: 104A PLSM112;
More informationConcept of Operations (CONOPS)
PRODUCT 0-6873-P1 TxDOT PROJECT NUMBER 0-6873 Concept of Operations (CONOPS) Jorge A. Prozzi Christian Claudel Andre Smit Praveen Pasupathy Hao Liu Ambika Verma June 2016; Published March 2017 http://library.ctr.utexas.edu/ctr-publications/0-6873-p1.pdf
More informationPERFORMANCE SPECIFICATION SHEET
INCH-POUND 5 October 2016 SUPERSEDING w/amendment 2 July 2016 PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUG, ELECTRICAL, COAXIAL, RADIO FREQUENCY, SERIES SMA (CABLED) PIN CONTACT, RIGHT ANGLE, CLASS
More information1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT
1995 Metric CSJ 0508-01-258 SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1.0 Description This Item shall govern for the furnishing and installation of color Single
More informationPRODUCT MANUAL. Chroma Flow PRO RGB LED Controller. and Receiver. Product Description. Main Functions: This manual reviews: Receiver.
Product Description The next generation of color changing Chroma Flow LED controllers is here with the new and even more advanced Chroma Flow PRO. The Chroma Flow PRO is a hand-held wireless remote control
More informationOperating Instructions
CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target
More informationMinimize your cost for Phased Array & TOFD
Minimize your cost for & TOFD Latest ultrasonic flaw detector from SIUI, SyncScan incorporates the latest advancements in high-performance and TOFD detection into one compact and durable unit. SyncScan
More informationDurham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications
Durham Magneto Optics Ltd NanoMOKE 3 Wafer Mapper Specifications Overview The NanoMOKE 3 Wafer Mapper is an ultrahigh sensitivity Kerr effect magnetometer specially configured for measuring magnetic hysteresis
More informationQuality products from a single source
Velocity sensors Quality products from a single source For more than 50 years Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.
More informationIGNITION TRANSFORMER FOR BURNERS
IGNITION TRANSFORMER FOR BURNERS TAR SERIES FEATURES TAR10 Bulletin E5004 rev06 13/11/03 115 / 230 V 50 / 60 Hz 2 / 1 A 220 VA Intermittence every 3 minutes: 20% 1.3 kg 38 cm Type of H.T. cable siliconic
More informationNominal Feet Feet List Price Pipe Item # I.D. x Length O.D. Per Bag Per Crate Per 100 Feet
Page 1, May 2006 CPVC Copper Tube Size Pipe & Fittings CPVC Copper Tube Size Pipe Tubing for use with CPVC CTS fittings for hot or cold water applications. Complies with ASTM D2846. Working pressure: 100
More informationA COMPARISON OF Mll...LIMETER WAVE AND EDDY CURRENT DETECTION OF SURFACE BREAKING DEFECTS IN CONDUCTING MATERIALS
A COMPARISON OF Mll...LIMTR WAV AND DDY CURRNT DTCTION OF SURFAC BRAKING DFCTS IN CONDUCTING MATRIALS S. Ross lectrical and Computer ngineering Department Iowa State University Ames, Iowa 5 11 M. Lusk
More information