Thermo-Simple 1 version 2 (TS.1 ver.2) 2013
|
|
- Tyrone Parks
- 6 years ago
- Views:
Transcription
1 Refrigeration Innovation Thermo-Simple 1 version 2 Manual Refrigeration Innovation 1250 Harter Avenue Suite E Woodland, CA P: Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 1 of 31
2 TABLE OF CONTENTS TABLE OF CONTENTS... 2 HARDWARE CONFIGURATIONS... 4 MULTI-NODE (SPINE) CONFIGURATIONS... 4 Power Supply for Multi-Node... 4 Junction Box (For Single Temperature Case)... 5 Junction Box (For Dual Temperature Case)... 6 Junction Box (Analog Output)... 6 Temperature vs. Voltage Chart... 7 SINGLE NODE CONFIGURATION... 8 Power Supply... 8 Dual temperature Power harness... 8 HARDWARE INSTALLATION... 9 MOUNTING PLATE SCREW CLEARANCES DISPLAY SCREW CLEARANCES DISPLAY UNIT DISPLAY MAGNETIC SWITCHES FEATURES AND FUNCTIONS Unlocking Display DISPLAY UNIT SETTINGS Function #1: Default Temperature Scale Function #2: Enable/Disable Defrost Indicator Function #3: Enable/Disable Freeze Alarm Function #4: Color Scheme Function #12: Alarm Flag Function #5: Set-Point Dual Set-Points (5.0 F and 40.0 F) F F (Dual Temp Low Setting) F F (Dual Temp Hi Setting) F with Freeze Alarm F F with Freeze Alarm F for Hot Foods Function #6: Defrost Timer WIRELESS INTERFACE SETTINGS Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 2 of 31
3 Function #7: Turn On/Off Wireless Module, and View Display Unit ID Turning Wireless Module ON View Wireless ID and Display unit ID Turning Wireless Module OFF Function #9: Replacing Display Unit Function #8: Assigning/Viewing Output Channel Channel Commission Code (CC Code) Function #13: Delete/Changing Output Channel Function #10: Assigning New Multi-Node ID Function #11: Replacing/Viewing Existing Multi-Node ID Replacing Existing Multi-Node ID Viewing Existing Multi-Node ID WIRED INTERFACE SETTINGS Function #14: Enable/Disable Analog Output ADVANCED SETTINGS Function #15: Enable Demo Mode WARRANTY Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 3 of 31
4 HARDWARE CONFIGURATIONS MULTI-NODE (SPINE) CONFIGURATIONS This configuration allows a single power supply to power up to 6 Thermo-Simple 1 and/or 2. Power Supply PN: PS Spine Cable 6 feet PN: Spine-6 Spine Cable 13 feet PN: Spine-13 Spine Cable 25 feet PN: Spine-25 Junction Box (Single Temp.) PN: ST-3 Junction Box (Dual Temp.) PN: ST-3-DT Sensor 6 feet PN: H3-6 Sensor 13 feet PN: H3-13 Sensor 25 feet PN: H3-25 Power Harness PN: H2-S Contact Cover PN: TS1-PC Mounting Harness PN: TS1-MP Display Unit PN: TS1-DS Power Supply for Multi-Node The power supply for Multi-Node Configuration is not interchangeable with Single Node power supply. This is due to different load requirements. INPUT Plug type: NEMA 1-15p Voltage: Vac(50-60 Hz) Current: 0.2 A OUTPUT Plug type: RJ45 (8 Positions 8 Contacts) Voltage: 12 Vdc Current: 1.5 A Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 4 of 31
5 Junction Box (For Single Temperature Case) There are three RJ45 receptacles. The main power receptacles are the 2 on left and right hand side. The third receptacle on the bottom provides regulated power output for Thermo-Simple thermometers. NOTE ON JUNCTION BOX CONNECTIONS: DO NOT connect Thermo-Simple Power harness, H2 harness, into any of the 2 main power receptacles. DO NOT connect Power Supply or Spine cable, into the third output receptacles. For proper connection please refer to the Multi-Node (Spine) Configuration diagram. SPINE Port: Connect Power Supply or Spine Cable here. WARNING: DO NOT connect H2-S Power harness in here. Thermo Simple Port: Connect Power harness (H2-S) here. WARNING: DO NOT connect Power Supply or Spine cable in here. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 5 of 31
6 Junction Box (For Dual Temperature Case) For dual temperature case, the set-point can be automatically switched between 5.0 F and 40.0 F depending on the Dual Temperature switch on the case. Therefore when the dual temperature case is switch between Frozen Food Case to Fresh Food Case, the display unit will automatically change its set-point to match the case temperature setting. This is for use only with 120v Low Temp solenoid applications. For dry contact applications see Page 8 For use only with 120 VAC Low Temperature Solenoid Application Voltage input from low temperature solenoid goes here. There is no polarity ( Hot and Neutral at 120Vac) Junction Box (Analog Output) For wired analog output application, the display unit temperature is expressed in voltage. The voltage can be measured from t he DAC OUT connector. It can be wired to any analog input boards in EMS Controller. EMS controller requires 0-5 VDC Analog Input Board and setting prior to connecting wires from ST-3 to analog input point. Analog Output (Volt DC) Top: + Bottom: -/Common Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 6 of 31
7 Temperature vs. Voltage Chart Voltage C F Voltage C F To setup the EMS Controller Analog Input Linear Analog Input set to Fahrenheit, voltage offset of: V and Gain of Linear Analog Input set to Centigrade, voltage offset of: V and Gain of Alternate Setting with 2 End-points: 0 Volts = 32 C (-25.6 F) 5 Volts = C ( F) Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 7 of 31
8 SINGLE NODE CONFIGURATION Node configuration is suitable for isolated cases, one power supply per Thermo-Simple device." Power Supply PN: PS Single Temp. Power Harness PN: H2-N Dual Temp. Power Harness PN: H2-N-DT Sensor 6 feet PN: H3-6 Sensor 13 feet PN: H3-13 Sensor 25 feet PN: H3-25 Dual Temp. Input Not available on Single Temp. Power Harness Mounting Harness PN: TS1-MP Display Unit PN: TS1-DS Power Supply INPUT Plug type: NEMA 1-15p Voltage: Vac (50-60 Hz) Current: 0.2 A OUTPUT Plug type: Molex 2 Pin Voltage: 12 Vdc Current: 0.35 A Dual temperature Power harness For dual temperature case with Dry Contact switch control. The dual temperature cable wire is orange and white orange. T here s no polarity. The wires connect to the switch in series. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 8 of 31
9 With Dual-Temp power harness the set-point can be automatically switched between 5.0 F (Low Temperature) and 40.0 F (Medium Temperature) depending on the Dual Temperature switch position on the case. When the switch is open, the set-point becomes F (Medium Temperature). When the switch is close, the set-point becomes +5.0 F (Low Temperature). When the case switches from F (Medium Temperature) to +5.0 F (Low Temperature) there will be a 30 minute delay to allow time for the case to cool down. However, when the case switches from +5.0 F (Low Temperature) to F (Medium Temperature) there will be no delay. When the dual temperature case is switch between Frozen Food Case to Fresh Food Case, the Thermo-Simple will change between +40 and +5 settings immediately. HARDWARE INSTALLATION Thermo-Simple 1 Version 2 consists of 2 main components. The first part, installed first in a case, is the Mounting Plate. The second part, attached to the Mounting Plate, is the Display Unit. The spring contact provides power and temperature reading to the Display unit. In order for the spring contact to work properly, it is imperative to use #6 Pan Head screws on the Mounting Plate and #4 Undercut Countersunk with length no longer than 3/16 inch. Display Screw: #4 x 3/16 40 Undercut-Countersunk self tapping screws Display Unit Mounting Plate Screws: #6 Pan head self tapping screws Spring Contact Mounting Plate Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 9 of 31
10 MOUNTING PLATE SCREW CLEARANCES Spring Contact Connection between Mounting Plate and Device s Main Boards It is critical that #6 or #8 Low Profile Pan Head screws are used to ensure proper device operation. DISPLAY SCREW CLEARANCES Main Board and Mounting Plate Clearances This clearance CANNOT be compromised for normal operation Clearance between #6 and #4 x screws MUST be maintained to ensure secured engagement between the Mounting Plate and the Device. Using longer and/or unspecified head type on #4 screws can compromise device operations It is critical that #4 x 3/16 Flathead Undercut Countersunk screws are used to ensure proper engagement between the Mounting Plate spring connector and the Device. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 10 of 31
11 DISPLAY UNIT DISPLAY Incoming Data Indicator (wireless system only) Temperature Scale Positive/Negative Temperature indicator Outgoing Data Indicator (wireless system only) Numeral Indicator (Temperature/Set-Point/ Device s Address/Status) TS.1.v2 displays temperature in its default state. It also displays incoming and outgoing communication between the device and the wireless network a wireless system. MAGNETIC SWITCHES Function/Enter /Confirm Switch Show Set-Point Setting Next/Up Switch Temp. Scale/Cancel/Escape Switch Show Last Alarm (in Hours) Previous/Down Switch To trigger the magnetic switch on the TS.1 device, a Refrigeration Innovation Magnet Tool is needed. In absence of the Magnet Tool, the magnetic switch on the TS.1 device can be triggered by any strong magnet (Neodymium rare-earth type). A typical refrigerator door magnet or whiteboard magnet are NOT strong enough). Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 11 of 31
12 FEATURES AND FUNCTIONS Unlocking Display After 4.5 minutes after being powered on. The display unit will automatically lock itself to prevent unintended changes. To unlock and change settings: 1. Trigger F/X switch. 2. Using Up/Down arrow turns the first digit to 5. Then set it by triggering the F/X switch 3. Repeat step 2 until all three digits are set to 567. The display unit will ask you to confirm this unlocking procedure. 4. Trigger F/X switch to confirm unlocking procedure. 5. The unit is now unlocked. You can now access Function #1 to #19 using the Up/Down switch. DISPLAY UNIT SETTINGS These functions list checks and changes the display unit internal settings. Function #1: Default Temperature Scale Changing default temperature scale. To change default temperature scale, unlock the display unit first, and then follow these steps: 1. Trigger F/X switch. The display unit will ask for what Function to select. 2. Select #1 using Up/Down switch. 3. Then trigger F/X switch again to confirm function selection. The display unit will show the current default temperature scale. 4. Select default temperature scale using Up/Down arrow 5. Trigger F/X switch to confirm your selection. The display unit default temperature scale is now in Celsius. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 12 of 31
13 Function #2: Enable/Disable Defrost Indicator When a refrigeration unit goes out of temperature, there may be nothing wrong at all. It is part of the refrigeration unit cycle to defrost. During this cycle by default the display unit will indicate def. If defrost indicator is disabled, the display unit will indicate temperature reading. Trigger the F/C switch to see temperature reading during this cycle. To enable/disable defrost indicator, unlock the display unit first, and then follow these steps: 1. Trigger F/X switch. The display unit will ask for what Function to select. 2. Select #2 using Up/Down switch 3. Then trigger F/X switch again to confirm function selection. The display unit will show the current Defrost indicator. +def means that the defrost indicator is on. -def means that the defrost indicator is off. 4. Turn off (or on) defrost indicator using Up/Down switch. 5. Trigger F/X switch to confirm your selection. Defrost indicator is now off. Function #3: Enable/Disable Freeze Alarm In some refrigeration case containing dairy, fresh produce, and other similar ingredients, it is necessary to keep the ingredients fresh and cool but not frozen. For these cases enabling freeze alarm on the display unit may be appropriate. By default, freeze alarm is disabled. If enabled, display unit will start flashing blue if the temperature drops below 33.5 F To enable/disable freeze alarm, unlock the display unit first, and then follow these steps: 1. Trigger F/X switch, the display unit will ask for what Function to select. 2. Select #3 using Up/Down switch Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 13 of 31
14 3. Then trigger F/X switch again to confirm function selection. The display unit will show the current Freeze alarm setting -Fr means that the freeze alarm is off +Fr means that the freeze alarm is on 4. Turn on (or off) freeze alarm using Up/Down switch. 5. Trigger F/X switch to confirm your selection. Freeze alarm is now enabled. Function #4: Color Scheme There are 3 color schemes available. 1. Blue Green Amber (BGA): Amber Alarm Solid Blue Frozen Status Solid Green Fresh Status Flashing Amber (after defrost / first 60 / first 90 minutes) Out of Temp. Alarm 2. Green Amber Red (GAR): Amber and Red Alarm Solid Green Fresh/Frozen Status Flashing Yellow Short duration over temp. alarm (first 60 / first 90 minutes ) Flashing Red Long duration over temp. alarm (After the first 60/ first 90 minutes of an Amber alarm) 3. No color (only temperature display) The default color scheme setting is BGA. To change the color scheme, unlock the display unit first, and then follow these steps: 1. Trigger F/X switch, the display unit will ask for what function to select. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 14 of 31
15 2. Select #4 using Up/Down switch 3. Then trigger F/X switch again to confirm function selection. The display will show the current color scheme. bga means Blue Green Amber. GAr means Green Amber Red. n-c means No color. 4. Select any color scheme using Up/Down switch. 5. Trigger F/X switch to confirm you selection. The color scheme is now Green Amber Red. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 15 of 31
16 Function #12: Alarm Flag If the unit ever went out of temperature the display unit will alternate between temperature reading and ALA. This means that even though the case is back in temperature, it has been out of temperature for more than 60 minutes previously. First 60 minutes after defrost timer is up (70 minutes on set-points with freeze alarm) The units will shows ALA on display along with flashing amber/yellow for the first 60 minutes after 60 minutes defrost timer is up. (70 minutes after 70 minutes defrost timer is up on set-point with freeze alarm) Master Alarm will turn on within 60 minutes (Wireless System Only) Display Alternates After an alarm condition has gone away The unit will go back to normal operation, however the display will alternate between ALA and the actual temperature, alternating approximately every three seconds. Magnet End To clear the alarm condition, Tap F/C here FIRST Tap F/C switch once using a RI Magik Wand or any strong magnet. Once the temperature goes back below (or over, for hot food set-point 142F), the TS.2 unit will display the temperature and ALA repetitively until F/C switch has been triggered. By default, the Alarm Flag is disabled To enable, unlock the display unit, and follow these steps: Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 16 of 31
17 1. Trigger F/X switch, the display unit will ask what function to select. 2. Using Up/Down switch select # Trigger F/X switch, the confirm function selection The display unit will show current ALA status. -ALA 4. Using Up/Down switch, turn ALA display on (or off) +ALA 5. Trigger F/X switch to confirm ALA setting Function #5: Set-Point Set-Point is a temperature point where a case turns from being in good status to alarm (out of temperature) status. There are 8 different set-points. Dual Set-Points (5.0 F and 40.0 F) For dual temperature case, the set-point can be automatically switched between 5.0 F and 40.0 F depending on the Dual Temperature switch on the case. Therefore when the dual temperature case is changes between Frozen Food Case to Fresh Food Case, the display unit will automatically change its set-point to match the case temperature setting. 0.0 F LED COLOR and STATE DESCRIPTIONS SOLID BLUE on BGA SOLID GREEN on GAR Below set-point. (-2 degree Fahrenheit) SOLID BLUE on BGA SOLID GREEN on GAR At set-point. (0 degrees Fahrenheit) SOLID PURPLE & def Above set-point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set-point for more than 60 minutes. (First Alarm with optional Red alarm) FLASHING RED (on GAR only) Above set-point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set-point: - Ice Cream - Frozen Foood 5.0 F (Dual Temp Low Setting) Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 17 of 31
18 LED COLOR and STATE DESCRIPTIONS SOLID BLUE on BGA SOLID GREEN on GAR Below set-point. (0 degree Fahrenheit) SOLID BLUE on BGA SOLID GREE on GAR At set-point. (5 degrees Fahrenheit) SOLID PURPLE & def Above set-point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set-point for more than 60 minutes. (First Alarm with optional Red alarm) FLASHING RED (on GAR only) Above set-point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set-point: - Ice Cream - Frozen Food 36.0 F LED COLOR and STATE DESCRIPTIONS SOLID GREEN Below set-point. (34.4 degree Fahrenheit) SOLID GREEN At set-point. (36 degrees Fahrenheit) SOLID PURPLE & def Above set-point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set-point for more than 60 minutes. (First Alarm with optional Red alarm) FLASHING RED (on GAR only) Above set-point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set-point: - Fresh Meat - Fresh Fish 40.0 F (Dual Temp Hi Setting) LED COLOR and STATE DESCRIPTIONS Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 18 of 31
19 SOLID GREEN Below set-point. (34.4 degree Fahrenheit) SOLID GREEN At set-point. (40 degree Fahrenheit) SOLID PURPLE & def Above set-point for the first time Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set-point for more than 60 minutes. (First Alarm with optional Red alarm) FLASHING RED (on GAR only) Above set-point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set-point: - Fresh Meat - Fresh Fish 43.0 F with Freeze Alarm LED COLOR and STATE DESCRIPTIONS FLASHING BLUE on BGA FLASHING RED on GAR Below freezing point. (Freeze Alarm starts at 33.5 degree Fahrenheit) SOLID GREEN At or below set-point. (43 degree Fahrenheit) SOLID PURPLE & def Above set-point for the first time. Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set-point for more than 60 minutes. (First Alarm with optional Red alarm) FLASHING RED (on GAR only) Above set-point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set-point: - Fresh Produce - Fresh Fruit 52.0 F LED COLOR and STATE DESCRIPTIONS Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 19 of 31
20 SOLID GREEN Below set-point. (40 degree Fahrenheit) SOLID GREEN At or below set-point. (52 degree Fahrenheit) FLASHING AMBER Above set-point for more than 60 minutes. (First Alarm with optional Red alarm) FLASHING RED (on GAR only) Above set-point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set-point: - Cheese - Delicatessens 57.0 F with Freeze Alarm LED COLOR and STATE DESCRIPTIONS FLASHING BLUE on BGA FLASHING RED on GAR Below freezing point. (Freeze Alarm starts at 33.5 degree Fahrenheit) SOLID GREEN At or below set-point. (57 degree Fahrenheit) SOLID PURPLE & def Above set-point for the first time Device assumes case is in Defrost for the first 60 minutes. FLASHING AMBER Above set-point for more than 60 minutes. (First Alarm with optional Red alarm) FLASHING RED (on GAR only) Above set-point for more than 120 minutes. (Second Alarm after Amber Alarm) Suggested Product for this Set-point: - Fresh Milk - Dairy Products 142 F for Hot Foods LED COLOR and STATE NO COLOR DESCRIPTIONS Case heaters are off or have been on for less than 60 minutes. Device assumes case is heating up for the first 60 minutes in this set-point. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 20 of 31
21 SOLID GREEN Case has reached or is above set-point. (Above 142 degree Fahrenheit) FLASHING AMBER Case has never reached set-point or has been below set-point for more than 60 minutes. Device assumes case failure and triggers the Amber Alarm. Any food should be removed until the case is repaired. Case has been below the set-point for more than 4 hours. FLASHING RED If prepared food has been in the case up to a Red Alarm the food should be discarded. (Second Alarm after Amber Alarm) Suggested Product for this Set-point: - Hot Foods - Prepared Foods The default set-point is 40.0 F. To change the set-point, unlock the display unit first, and then follow these steps: 1. Trigger F/X switch, the display will ask for what function to select. 2. Select #5 using Up/Down switch 3. Then trigger F/X switch again to confirm function selection. The display unit will show the current set-point. (or 4.4 C if the default temperature scale is in Celsius) 4. Select any set-point using Up/Down switch. (or C if the default temperature scale is in Celsius) 5. Trigger F/X switch to confirm your selection. The set-point is now 5.0 F (or C if the default temperature scale is in Celsius) Function #6: Defrost Timer On larger case it may takes more time to get back into temperature after defrost cycle has end. For that the display unit can be adjusted for 60 or 90 minutes defrost cycle. The default defrost timer is 60 minutes. To change the defrost timer, unlock the display unit first, and then follow these steps: 1. Trigger F/X switch, the display unit will ask for what function to select. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 21 of 31
22 2. Select #6 using Up/Down switch 3. Then trigger F/X Switch again to confirm function selection. the display unit will show the current defrost timer in minutes d60 means the defrost timer is 60 minutes before going into alarm mode 4. Change the defrost timer to 90 minutes using Up/Down switch. 5. Trigger F/X switch again to confirm you selection. The defrost timer is now set to 90 minutes before going into alarm. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 22 of 31
23 WIRELESS INTERFACE SETTINGS For this function list to have any effect, a Wireless Display Unit is required. The difference between Non-Wireless and Wireless Display unit This is a Non-Wireless Display Unit. There is no wireless module installed This is Wireless Display Unit. There is a wireless module installed. These functions list governs how the display unit interfaces and communicates through wireless network. With in a single wireless network (a single Wireless ID), the Display Unit ID is unique. There can be more than one wireless network running at the same time. In this case, two or more display units may have the same ID but they belong to different Wireless ID s Wireless ID #AA Wireless ID #AB Wireless ID #BB Display Unit ID #1 Display Unit ID #1 Display Unit ID #1 Display Unit ID #2 Display Unit ID #2 Display Unit ID #2 Display Unit ID #3 Display Unit ID #3 Display Unit ID #3 Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 23 of 31
24 Function #7: Turn On/Off Wireless Module, and View Display Unit ID If the display unit is part of the Wireless Network, this is the function to check for the display unit ID. By default the display unit is not jointed (Wireless Module turned off) to any wireless network. Turning Wireless Module ON To turn on wireless module, unlock the display unit first, and then follow these steps: 1. Trigger F/X switch, the display unit will ask for what function to select. 2. Select #7 using Up/Down switch. 3. Trigger F/X switch to confirm function selection. It will show -Jna, since wireless module is turned off 4. Using Up/Down switch. Turn wireless module on 5. Trigger F/X switch to confirm your selection. The display unit will then ask for wireless ID to join to. Note that the first dash is blinking Using Up/Down switch, set the first digit of the wireless ID to joint to. Select any character between 1 to 9 and also between A to F In this case, I ve selected D as the first digit 6. Trigger F/X switch to confirm your selection. Note that the second digit is now blinking. Using Up/Down switch set the second digit of the wireless ID to joint to. Select any character between 1 to 9 and also between A to F In this case, I ve selected 9 as the second digit. 7. Trigger F/X switch again to save and confirm the Wireless ID for the display unit to join. The display unit will count up as the Wireless Module is turning on. Note how the counts is adjusted to the left Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 24 of 31
25 8. Please wait as the Wireless Module is obtaining Display Unit ID The Display Unit ID will be displayed adjusted to the right. In this case the display unit has obtained the ID #4 on Wireless ID # D9 9. Trigger F/C to go back to temperature display. However, you may want to set output channel for this device. Please refer to Function #8: Setting Output Channel View Wireless ID and Display unit ID In the case of replacement, maintenance, or documentary purposes, it is useful to know the Display Unit ID and what Wireless ID a particular display unit is connected/jointed to. To check the Display Unit ID and Wireless ID for a particular display, unlock the display unit first, and then follow these steps: 1. Trigger F/X switch, the display unit will ask what function to select. 2. Select #7 using Up/Down switch 3. Trigger F/X switch. If the unit displays -Jna the wireless module is off If the unit displays +Jna the wireless module in on. In this case the wireless module is on. 4. Trigger F/X switch to check Wireless ID If the unit displays, that mean that the unit has not been jointed to any wireless network before. In this case, the unit is connected to Wireless ID # D9 5. Trigger F/X switch again to check Display Unit ID The display unit will count up as the Wireless Module is turning on. Note how the counts is adjusted to the left 6. Please wait as the Wireless Module is obtaining Display Unit ID The Display Unit ID will be displayed adjusted to the right. In this case the display unit has obtained the ID #4 on Wireless ID # D9 7. Trigger F/C to go back to temperature display. Turning Wireless Module OFF In the case of replacement, maintenance, or documentary purposes, it is useful to turn off wireless module on a display unit. To turn off wireless module, unlock the display unit first, and then follow these steps: Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 25 of 31
26 1. Trigger F/X switch, the display unit will ask what function to select. 2. Select #7 using Up/Down switch 3. Trigger F/X switch, if the unit displays -Jna the wireless module is already turned off In this case the wireless module is on. 4. Select -Jna using Up/Down switch 5. Trigger F/X switch to confirm. Wireless module is now off. The unit will display temperature reading. Note that the arrows are now no longer blinking. Function #9: Replacing Display Unit To replace an existing display unit, the following information from the existing display unit must be obtained: 1. Display Unit ID # Please refer to Function #7 to obtain Display Unit ID # from the existing unit 2. Wireless ID # Please refer to Function #7 to obtain Wireless ID # from the existing unit Once this information has been obtain from the existing display unit. Unlock the replacement unit, if it s locked. Then perform the following on the replacement unit: 1. Trigger F/X switch, the display unit will ask for what function to select. 2. Using Up/Down switch, select # The display unit will ask for the Wireless ID # of the existing display unit to be replaced. P 4. Using Up/Down key select the first digit of the Wireless ID # Pd In this case the display unit to be replaced belonged to Wireless ID # that starts with a D 5. Trigger F/X switch to confirm the first digit. Using the Up/Down key select the second digit of the Wireless ID # Pd2 In this case the display unit to be replaced belonged to Wireless ID # D2 6. Trigger F/X switch to confirm you selection. rpl (or did for display ID) 7. Using Up/Down key select the Display Unit ID # to replace (on Wireless ID # D2) 4 In this case, we are replacing Display Unit ID #4 Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 26 of 31
27 8. Trigger the F/X key to confirm display unit ID #. The display unit will count up as the Wireless Module is turning on. Note how the counts is adjusted to the left 9. Please wait as the Wireless Module is replacing Display Unit ID The Display Unit ID will be displayed adjusted to the right. This display unit is successfully replaced. Function #8: Assigning/Viewing Output Channel For the Energy Management Controller to receive temperature data from the display unit, we need to assign an output channel f or it. Output channel is a path from the Display Unit to the Energy Management (EMS) Controller. So that temperature data from the display unit can be properly routed to the EMS Controller. Display unit are assigned an output channel by entering a Board #, Point #, and Sensor #. By default, Output Channel is not set. To assign or view output channel, unlock the display unit, and then follow these steps: 1. Trigger F/X switch, the display unit will ask what function to select. 2. Select #8 using Up/Down switch 3. Trigger F/X switch. If display unit has an output channel, then it will display the Board number. In this case, the output channel has not been set yet. 4. Using Up/Down switch, select board number from In this case, we are routing the display unit temperature data to board #5. 5. Trigger F/X switch to confirm board number selection. Display unit will ask for a point number in board #5. If display unit has an output channel, then it will display the Point number In this case, the output channel has not been set yet. 6. Using Up/Down switch, select point number. In this case, we are routing the display unit temperature data to board #5 and point #1 Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 27 of 31
28 7. Trigger F/X switch to confirm point number selection. Display unit will ask for sensor #. If display unit has an output channel, then it will display the Sensor number In this case, the output channel has not been set yet. 8. Using Up/Down switch, select sensor number. In this case, we are routing the display unit temperature data from Sensor #1 to board #5 and point #1 9. Trigger F/X switch to confirm sensor number selection. Wait for display unit Channel Commission Code (CC Code) Here is the Code Table: Channel Commission Code (CC Code) Code Descriptions -0- Output channel point has been commission/decommissioned successfully, green LED -1- Output channel point has been assigned to a different display unit, red LED -2- Output channel point has been assigned to another sensor# on this display unit, red LED -3- Sensor # is already assigned to a different output channel point, red LED -4- Output channel has not been assigned, Red LED -5- Controller (PANID?) does not exsist, red LED Board Number is out of range, red LED Please make sure there are input board installed Point number is out of range. Some input boards such as Micro-Thermo or Danfoss only goes up to 8 and 4 channels in a board. -8- Sensor number in out of range, red LED Function #13: Delete/Changing Output Channel When a refrigeration unit is replace with a different one, there may be a need to delete associated output channel. To delete/change existing output channel, unlock the display unit, and follow these steps: 1. Trigger F/X, the display unit will ask what function to select. 2. Using Up/Down switch select Function # Trigger F/X switch to confirm function selection. Function #10: Assigning New Multi-Node ID Multi-Node ID is another form of Display Unit ID# for display unit in Multi-Node configuration. A power supply called the Row Control Computer (RCC) is required. This function is suitable for assigning new display unit. By default, the display unit has no multi-node ID. To add a multi-node ID to RCC register, unlock the display unit, and follow these steps: Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 28 of 31
29 1. Trigger F/X switch, the unit will ask what function to select. 2. Using Up/Down switch select # The display unit will prompt, that it is ready to add multi-node ID# +Add 4. Trigger F/X switch to confirm your selection. The display will blink 3 dashes as it waits for multi-node ID # (blinking) 5. Once the display is showing a number and blinking. Multi-Node ID has been assigned successfully. In this case the RCC has assigned Multi-Node ID # 4 Function #11: Replacing/Viewing Existing Multi-Node ID Multi-Node ID is another form of Display Unit ID# for display unit in Multi-Node configuration. A power supply called the Row Control Computer (RCC) is required. This function is suitable for replacing a display unit that has specific Multi-Node ID. Do not assign new display unit using this function. RCC will not recognize Multi-Node ID# set using this function. By default, the new display unit has no multi-node ID. Replacing Existing Multi-Node ID To set the new display unit to existing Multi-Node ID, unlock the display unit, and then follow these steps: 1. Trigger F/X switch, the display unit will ask what function to select. 2. Using Up/Down arrows, select # Trigger F/X switch to confirm function selection. If the new unit has old Multi-Node ID, it will display it. In this case the unit is factory default. 4. Using Up/Down switches, select existing Multi-Node ID. 2 In this case, we re replacing an existing display unit with Multi-node ID #2 5. Trigger F/X switch, to confirm selection in/out arrows 2 (blinking) The display unit is success fully replaced. Viewing Existing Multi-Node ID To view Multi-Node ID on the display unit, unlock the display unit, and then follow these steps: 1. Trigger F/X switch, the display will ask what function to select. 2. Using Up/Down arrow, select #11 11 Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 29 of 31
30 3. Trigger F/X switch to confirm function selection. By default, the unit should not have any Multi-Node ID # ( ) In this case the unit Multi-Node ID is Trigger F/C switch to go back to temperature display DO NOT trigger any other switch. You may changes the Multi-Node ID and interrupt network communication. WIRED INTERFACE SETTINGS Function #14: Enable/Disable Analog Output The display unit is capable of providing an Analog Voltage to allow direct connection to any device with an Analog input for reading temperature. This allows direct connection from the unit to the EMS Controller. This function requires Multi-Node (Spine) Hardware Configuration By default the analog output is disabled. To enable analog output, unlock the display unit, and follow these steps: 1. Trigger F/X switch, the display unit will ask what function to select 2. Select #14 using Up/Down switch Trigger F/X switch to confirm function selection. The display will show current state of Analog Output -DAc In this case the analog output is disabled. 4. Using Up/Down enable analog output +DAc 5. Trigger F/X switch to confirm selection Analog output is now enabled ADVANCED SETTINGS Additional settings are available to simplify tasks and troubleshooting. Function #15: Enable Demo Mode To show case the capability and simplicity of the product this function is available. By default, this function is disabled. To enable this function, unlock the display unit, and follow these steps: 1. Trigger F/X switch, the display unit will ask what function to select. 2. Select #15 using Up/Down switch Trigger F/X switch to confirm function selection. WARRANTY 2-Year Warranty Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 30 of 31
31 Thermo-Simple 1 version 2 from Refrigeration Innovation, (the "Product"), is warranted against defects in materials and workmanship under normal use, for a period of 2-years from the date of purchase. In the event of a product failure due to materials or workmanship, Refrigeration Innovation will repair or replace the defective product. For warranty service, return the defective product to Refrigeration Innovation, shipping prepaid, for prompt repair or replacement. The foregoing sets forth the full extent of Refrigeration Innovation s warranties regarding the Product. Repair or replacement at Refrigeration Innovation s option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND REFRIGERATION INNOVATION SPECIFICALLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL REFRIGERATION INNOVATION, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOSS OF PRODUCT, LOST PROFITS OR SAVINGS, OR OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. THEREFORE, THE FOREGOING EXCLUSIONS MAY NOT APPLY IN ALL CASES. This warranty provides specific legal rights. Other rights which vary from state to state may also apply. Refrigeration Innovation, LLC Harter Avenue, Suite E, Woodland, CA Page 31 of 31
Defrost Control Installation and Programming of Version 3.1 Cards
Defrost Control Installation and Programming of Version 3.1 Cards INDEX 1. Introduction 2. Installation 3. Operation 4. Programming 5. Description Lists 6. Configuration Sheet NOTE: throughout the text,
More informationExtender w/ RS-232 and 2-way IR
Extender w/ RS-232 and 2-way IR GTB-UHD2IRS-ELRPOL-BLK User Manual Release A3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions.
More informationAE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT
FN: 341MAN1.DOC AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT DESCRIPTION AE Series Process Indicators are available with 1", 2.3", 4", 8", or 12" high digits,
More informationAudio. 4K Ultra HD Extender. w/ RS-232 and 2-way IR GTB-UHD2IRS-ELRPOL-BLK. User Manual. Release A2
Audio 3GSDI Embedder 4K Ultra HD Extender w/ RS-232 and 2-way IR GTB-UHD2IRS-ELRPOL-BLK User Manual Release A2 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed
More informationST-4000 SIGNAL LEVEL METER
ST-4000 SIGNAL LEVEL METER Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter.... 3 Quick Use Instructions.. 3 Main
More informationUSER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1
by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information
More informationModel Number ALS-ELUM-RGB-CNTRL-1. elum RGB Controller
Model Number ALS-ELUM-RGB-CNTRL-1 Installation INSTRUCTIONS elum RGB Controller Table of Contents 1.0 General Information..... 2.0 Connections...... 3.0 Switches......... 4.0 Indicators... 5.0 DMX Operation...
More informationAES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:
More informationUSER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0
by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information
More informationST-4000D SIGNAL LEVEL METER
ST-4000D SIGNAL LEVEL METER Rev 100606 Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter...... 3 Quick Use Instructions.....
More informationHTP1502W1 Remote Controlled Multicolor Lighting System
Page 1 of 8 CHATSWORTH, CALIFORNIA 91311 USA www.cyron.com HTP1502W1 Remote Controlled Multicolor Lighting System Thank you for purchasing CYRON HTP1502W1 LED Lighting System. This system will bring the
More informationOPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)
user instructions 711 HULMAN STREET PO BOX 2128 TERRE HAUTE, IN 47802 812-235-6167 FAX 812-234-6975 OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES) Models: 104A PLSM112;
More informationCC2000 SERIES SYSTEM CLOCKS / DISPLAYS
FN:CC2KMAN1.DOC CC2000 SERIES SYSTEM CLOCKS / DISPLAYS DESCRIPTION CC2000 Series System Clocks provide an economical solution for any size clock system. They are easily corrected by master clock systems
More informationAEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS
FN:200FMAN1.DOC AEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS DESCRIPTION AEXX-200F Series Line Frequency Monitors are precision large digital displays that measure power line frequency with a 0.01
More informationSTD-525T PRECISION TIMER
FN:STD525TM1.DOC STD-525T PRECISION TIMER DESCRIPTION The STD-525T Precision Timer measures and displays accurate elapsed time in minutes, seconds, tenths of seconds, and hundredths of seconds (MM.SS.TH)
More informationAtlona HDBaseT-Lite Transmitter over Single CAT5e/6/7
Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7 AT-HDTX User Manual Table of Contents 1. Introduction... 3 2. Package Contents... 3 3. Features... 3 4. Specifications... 3 5. Panel Descriptions a.
More informationAES-404 Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web: www.broadcast-devices.com
More informationSCALE & WEIGHT DISPLAYS
The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters
More informationDigital Lighting Systems, Inc.
, Inc. Series DMX CHASER/CROSS-FADER Controllers MODE RUN RATE MAX. MIN. Lighting Animation Controller FADE AUTO STOP BLK. OUT DIM1 DIM2 DIM3 DIM4 MODEL NUMBERS 2 2C Miami, Fl. USA digitallighting.com
More informationWarner Photoscanner MCS-500 Series LED Photoelectric Control
Warner Photoscanner MCS-500 Series LED Photoelectric Control P-241-100 819-0504 Installation & Operating Instructions Contents Description.............................. 2 Specifications.........................
More informationUser Manual. AtlonA. 1 x 10 VGA with Stereo Audio Distribution Amplifier over CAT5/6 compatible with AT-VGA300RL AT-VGA10SS
User Manual AtlonA 1 x 10 VGA with Stereo Audio Distribution Amplifier over CAT5/6 compatible with AT-VGA300RL AT-VGA10SS TABLE OF CONTENTS 1. Introduction... 3 2. Package Contents... 3 3. Features...
More informationFOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)
FOTS100 User Manual BIOPAC Systems, Inc. 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066, Fax (805) 685-0067 WWW.BIOPAC.COM 1 WARRANTY All products manufactured by Opsens inc. are warranted to be free
More informationLow Voltage Multifunctional LED Controller / DMX Decoder. Specification
Low Voltage Multifunctional LED Controller / DMX Decoder Specification High Power DMX Decoder & Driver Meets DMX 512/1990 Protocol LT-300 can drive up to 8A current on each channel Capable of driving many
More informationKNX Dimmer RGBW - User Manual
KNX Dimmer RGBW - User Manual Item No.: LC-013-004 1. Product Description With the KNX Dimmer RGBW it is possible to control of RGBW, WW-CW LED or 4 independent channels with integrated KNX BCU. Simple
More informationCH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide
1 1 CH1 CH2 1 1 CH4 CH 1 CH3 6s Master /Fade CH6 1 SC1 6s SC4 SC2 SC SC3 SC6 Off/Pro AL Fade 6 Pro User guide CONTENTS INTRODUCTION...2 Welcome 2 Safety 2 Supplied items 3 INSTALLATION...4 Mounting 4
More informationWarranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.
7 7 Port, or or Windows Port Warranty and Registration Warranty: One Year Registration: Please register your product at www.aitech.com 2007 AITech International. All rights reserved. WEB CABLE PLUS PC-TO-TV
More informationWaveRider Trouble Shooting Guide
WaveRider Trouble Shooting Guide www.heartlandmicropayments.com 2115 Chapman Road, Suite 159, Chattanooga TN 37421 800.332.4835 Table of Contents 1. Welcome... Page 3 2. Introduction... Page 4 3. System
More informationModel PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts
Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts INSTRUCTION MANUAL Sonics & Materials, Inc. 53 Church Hill Road Newtown, CT 06470 USA 203.270.4600 800.745.1105 203.270.4610 fax www.sonics.com
More informationVGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual
VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual INTRODUCTION Congratulations on your purchase of the VGA CAT-5 1:8 Distribution S. Your complete satisfaction
More informationModel R177M and R177S Baseband Switch
Model R177M and R177S Baseband Switch Installation Guide P/N 1340192 082304 Monroe Electronics 100 Housel Ave Lyndonville NY 14098-0535 800-821-6001 585-765-2254 fax 585-765-9330 www.monroe-electronics.com
More informationTC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual
TC3004 50Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication,
More informationChildren cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.
5.1 FLAT PANEL SPEAKER SYSTEM WITH POWERED SUBWOOFER Table of Contents: SAFETY AND SERVICE... 2 Operational Safety... 2 Location... 2 Ambient Temperature... 3 Electromagnetic Compliance... 3 Service...
More informationINSTALLATION MANUAL Model: HMDD. ATSC/QAM Digital Mini Demodulator
INSTALLATION MANUAL Model: HMDD ATSC/QAM Digital Mini Demodulator 1 PACKAGE CONTENTS This package contains: One HMDD ATSC/QAM Mini Demodulator One HMDD Installation Manual PRODUCT DESCRIPTION The HMDD
More informationOperating Manual for Clock / Auxiliary Displays for VHX systems
Operating Manual for Clock / Auxiliary Displays for VHX systems The VHX auxiliary display module is designed to work with a Dakota Digital VHX system and will not function properly on its own. With this
More informationUSER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)
USER MANUAL MODEL 460RC Rack-Mounted G.70 Coax to Twisted Pair Adapters (BALUNs) An ISO-900 Certified Company Part # 07M460RC-A Doc. #0908UA Revised //98 SALES OFFICE (0) 975-000 TECHNICAL SUPPORT (0)
More informationValcom Wired Digital Clock
Installation Manual V10.5 Valcom Wired Digital Clock V-D11025B, V-D11040B, V-D2425B, V-D2440B, V-2425B-6, and V-D2440B-6 Current as of February 2017 Valcom, Inc. Valcom Digital Series 2-Wire and 3-Wire
More informationSDI-HDSDXPRO. USER MANUAL Version 1.1
USER MANUAL Version 1.1 Index Description... 3 Features... 3 Connection Diagram... 4 Front Panel... 5 Rear Panel... 5 Dip Switch... 6 EDID Leaning... 7 Specifications... 8 Firmware Upload... 9 Update List...
More information1 x 10 Component Video with Stereo and Digital Audio Distribution Amplifier over CAT5/6 compatible with AT-COMP300RL AT-COMP10SS
1 x 10 Component Video with Stereo and Digital Audio Distribution Amplifier over CAT5/6 compatible with AT-COMP300RL AT-COMP10SS User Manual www.atlona.com TABLE OF CONTENTS 1. Introduction 2 2. Features
More information4X1 Gefen TV Switcher GTV-HDMI N. User Manual
4X1 Gefen TV Switcher GTV-HDMI1.3-441N User Manual INTRODUCTION Congratulations on your purchase of the 4x1 GefenTV Switcher. Your complete satisfaction is very important to us. GefenTV GefenTV is a unique
More informationAudio. Extender. for HDMI GBT-HDBT-POL. User Manual. Release A7
Audio 3GSDI Embedder Extender for HDMI GBT-HDBT-POL w/pol User Manual Release A7 Extender for HDMI w/pol Important Safety Information 1. Read these instructions. 2. Keep these instructions. 3. Heed all
More informationExtender for HDMI over one CAT5
1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:
More informationIn-Wall Control Mount for ipod Touch
In-Wall Control Mount for ipod Touch INTRODUCTION The Mirage KP-iOS is an in-wall system that allows ipod touch (4th generation) to become a semi-permanent fixture in your wall. The system allows you to
More informationUser Manual. AtlonA. Passive VGA Extender with Wall Plate or Box options up to 330ft over 1 x CAT5/6/7 Cable AT-VGA100-SR and AT-WPVGA-SR AT-WPVGA-SR
User Manual AtlonA Passive VGA Extender with Wall Plate or Box options up to 330ft over 1 x CAT5/6/7 Cable AT-VGA100-SR and AT-WPVGA-SR AT-WPVGA-SR Receiver Transmitter AT-VGA100-SR Receiver Transmitter
More informationFor use with QED and hardwired control panels ONLY!
K3129-5 10/98 6128WL Keypad/Receiver INSTALLATION INSTRUCTIONS For use with QED and hardwired control panels ONLY! General Information The 6128WL Keypad/Receiver is a combination unit. It replaces a 6128
More informationSetup Guide. Introduction
TM VGAEXTX1 Setup Guide Table of Contents 1) Introduction. 1 2) Specifications. 2 3) Package Contents. 2 ) Unit Layout & Description. 3 5) Connection and Operation. 6) Connection Diagram.......................
More informationQCA9-33 Active Combiner
Product Manual QCA9-33 Active Combiner April 13, 2012 Table of Contents Table of Contents... 2 Overview... 3 Specifications... 4 Installation... 5 Basic Setup... 5 16-Channel Operation... 5 16-64 Channel
More informationMiniModules. Reference Manual. Series P MX 3312/3313 D Dual Analog Audio Multiplexer. LYNX Technik AG
Reference Manual P MX 3312/3313 D Dual Analog Audio Multiplexer Series 3000 MiniModules LYNX Technik AG P MX 3312 D SDI IN n.c. SDI out 1 SDI out 2 SDI out 3 Audio in SDI out 4 Dual Analog Audio Multiplexer
More informationInstruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1
Instruction Manual 2.4G Digital Wireless Four Channel Transmitter System RVS-554W 1 NOTE! Please read all of the installation instructions carefully before installing the product. Improper installation
More informationSDI-SDHDXPRO User Manual. Version1.2
User Manual Version1.2 INDEX Description... 3 Feature... 3 Connection Diagram... 4 Front Panel... 5 Rear Panel... 5 Dip Switch... 6 Specifications... 7 Firmware Upload... 8 Update List... 10 Warranty...
More informationUSER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE
1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting and advanced relay sequencing. The contains
More informationVGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R
VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax
More information32 Channel CPCI Board User Manual
0 Sections Page 1.0 Introduction 1 2.0 Unpacking and Inspection 1 3.0 Hardware Configuration 1 4.0 Board Installation 5 5.0 I/O Connections and the Front Panel 5 5.1 Front Panel Layout 5 5.2 Input and
More informationAVE-301T AVE-301R AVE-304T AVE-308T AVE-316T
VGA and Audio CAT-5 AV Extender AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T User Manual V1.2 www.databay.com.tw www.green-box.com.tw Contents 1. Product Introduction...4 2. Product Features...5 3. System
More informationLBS-1 (Lowrance Broadband Sounder)
Pub. 988-0170-001 LBS-1 (Lowrance Broadband Sounder) Installation Instructions The LBS-1 is a digital sonar optimizer designed to enhance sonar echo clarity. The broadband sounder was created to deliver
More informationINSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR
INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form
More informationHDSP2X4. HDMI 2 x 4 Splitter with Full HD 1080p
HDSP2X4 HDMI 2 x 4 Splitter with Full HD 1080p TM TM HDSP2X4 Setup Guide Table of Contents 1) Introduction. 3 2) Specifications. 4 3) Package Contents 4 4) Unit Layout & Description 5 5) Connection and
More informationSprite TL Quick Start Guide
Sprite TL Quick Start Guide with 115 VAC Power Cord and 4-Conductor Signal Cable Reference Manual Sprite TL Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com
More informationProvides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.
USER S GUIDE PROGRAMMABLE 3-RELAY LOGIC MODULE 1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting
More informationWIRING INSTRUCTIONS CROP-LINK Drip Installation
WIRING INSTRUCTIONS 2011-14 CROP-LINK Drip Installation Items Covered In This Manual: Page 1: Crop Link Device Overview Page 2-3: Sensor Connections Page 4: Power and Relay Wiring Page 5-6: Specs and Warranty
More informationPSM-003. Micro Polarization Controller/Scrambler. User Guide
PSM-003 Micro Polarization Controller/Scrambler User Guide Version: 1.0 Date: August 23, 2012 General Photonics, Incorporated is located in Chino California. For more information visit the company's website
More informationJ C F A U D I O DA8-V DA8-V USER MANUAL JCF AUDIO, LLC CAMARILLO ST. NORTH HOLLYWOOD, CA
J C F A U D I O DA8-V DA8-V USER MANUAL JCF AUDIO, LLC. 11247 CAMARILLO ST. NORTH HOLLYWOOD, CA 91602 WWW.JCFAUDIO.COM contact@jcfaudio.com 11 2 4 7 C a m a r i l l o S t. N. H o l l y w o o d, C A 9 1
More informationSOURCE COMMANDER MSS433 A/V SELECTOR OWNER S MANUAL INSTALLATION GUIDE
SOURCE COMMANDER MSS433 R L V R L V R L V R L V M U L T I S T A T I O N A/V SELECTOR OWNER S MANUAL INSTALLATION GUIDE OWNER S MANUAL/INSTALLATION GUIDE WARNING! THE CLARION MSS433 MULTISTATION A/V SELECTOR
More informationSDI-HDRPTPRO. User Manual. HD-SDI Repeater with Signal Equalization & Re-clocking. Version 1.2
HD-SDI Repeater with Signal Equalization & Re-clocking User Manual Version 1.2 Index Introduction... 3 Features... 3 Package Includes... 3 Connection Diagram... 4 Front Panel... 5 Rear Panel... 5 Specifications...
More informationSentinel I24 Digital Input and Output Configuration
Application Bulletin: #155 Date: October 19, 2007 Sentinel I24 Digital Input and Output Configuration The Sentinel I24 can communicate with external hardware using digital inputs and outputs. There are
More informationInstruction Manual Model BlockUpconverter
Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationCHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC
CHECK LINE BY ELECTROMATIC Stationary Stroboscope Model LS-36-LED Operating Manual Table of Contents 1.0 Introduction... 02 1.1 Unpacking 1.2 Optional Accessories 2.0 Safety Information... 3 3.0 Controls...
More informationSAWM60 AUDIO/VIDEO MODULATOR
SAWM60 LIMITED WARRANTY Holland Electronics LLC, warrants that the product enclosed with this Limited Warranty statement will conform to the manufacturer s specifications and be free of defects in the
More informationHDMI Extender over UTP Cable
User Manual HDMI Extender over UTP Cable VHDE-300 Tx Rx Features.. Extends HDMI 1080p AV and IR Signals Transmission distance up to 60m/200ft via CAT6 cable or higher grade cable 5V DC, 1A Important Safety
More informationQDA4-44 RF Amp/Combiner
Product Manual QDA4-44 RF Amp/Combiner May 17, 2012 Table of Contents Table of Contents... 2 Overview... 3 Specifications... 4 Installation... 5 Basic Setup... 5 Rack Mounting... 6 RK2 Dual Rack Kit with
More informationVGA Extender LR EXT-VGA-141LR. User s Manual
VGA Extender LR EXT-VGA-141LR User s Manual ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru
More informationSetup Guide. Introduction
TM EXTX4 Setup Guide Table of Contents ) Introduction. 2) Specifications. 2 3) Package Contents. 2 4) Unit Layout & Description. 3 5) Connection and Operation. 3 6) Connection Diagram.......................
More informationHMA-860H AGILE MODULATOR
HMA-860H AGILE MODULATOR LIMITED WARRANTY Holland Electronics LLC, warrants that the product enclosed with this Limited Warranty statement will conform to the manufacturer s specifications and be free
More informationINSTALLATION MANUAL. Model: HDD. ATSC/QAM Digital to Analog Demodulator
INSTALLATION MANUAL Model: HDD ATSC/QAM Digital to Analog Demodulator Caution: These servicing instructions are for use by qualified service personnel only. To reduce the risks of electric shock, do not
More informationSR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013
SR - 516D DESK TOP DMX REMOTE STATION Version: 1.10 Date: 05/16/2013 Page 2 of 10 TABLE OF CONTENTS DESCRIPTION 3 POWER REQUIREMENTS 3 INSTALLATION 3 CONNECTIONS 3 POWER CONNECTIONS 3 DMX CONNECTIONS 3
More informationAES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-408 8 Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide
More informationModel Number Structure
Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control
More informationLavryBlack Series Model DA10 Digital to Analog Converter
LavryBlack Series Model DA10 Digital to Analog Converter Lavry Engineering, Inc. P.O. Box 4602 Rolling Bay, WA 98061 http://lavryengineering.com email: techsupport@lavryengineering.com January 14, 2008
More informationUC1000 Universal Controller
UC1000 Universal Controller Makes the KING Quest Satellite Antenna System compatible with DIRECTV DISH Bell TV Please read the! BEFORE YOU START! section on the inside of this cover before using the UC1000
More informationFN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N
FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N TABLE OF CONTENTS 1.0 INTRODUCTION 2.0 SPECIFICATIONS 3.0 INSTALLATION 4.0 GETTING STARTED 4.1 The Auto-Prompt Display 4.2 The Cursor, Entering Data 4.3
More informationUser Manual. VGA and Audio Cat-X AV Extender V1.0 AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T AVE-304TR AVE-308TR
VGA and Audio Cat-X AV Extender AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T AVE-304TR AVE-308TR User Manual V1.0 www.green-box.com.tw www.data-av.com Contents 1. Product Introduction...4 2. Product Features...5
More informationimso-104 Manual Revised August 5, 2011
imso-104 Manual Revised August 5, 2011 Section 1 Getting Started SAFETY 1.10 Quickstart Guide 1.20 SAFETY 1.30 Compatibility 1.31 Hardware 1.32 Software Section 2 How it works 2.10 Menus 2.20 Analog Channel
More informationDUAL/QUAD DISPLAY CONTROLLER Operation Manual
DUAL/QUAD DISPLAY CONTROLLER Operation Manual Model PXD524 MicroImage Video Systems division of World Video Sales Co., Inc PO Box 331 Boyertown, PA 19512 Phone 610-754-6800 Fax 610-754-9766 sales@mivs.com
More informationExtender for HDMI. gefentoolbox.com GTB-HDBT-POL GTB-HDBT-POL-BLK. User Manual
Extender for HDMI w/pol GTB-HDBT-POL GTB-HDBT-POL-BLK User Manual gefentoolbox.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support
More informationModel /29S RF Splitter
Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary
More information1X4 HDMI Splitter with 3D Support
AV Connectivity, Distribution And Beyond... VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES 1X4 HDMI Splitter with 3D Support Model #: SPLIT-HDM3D-4
More informationInstruction Manual Model # Block Upconverter
Instruction Manual Model 2115-278# Block Upconverter August 2018, Rev. A MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationPoE Over Coax Extender Kit
Comply with IEEE.802.3af User Manual Data Sheet PoE Over Coax Extender Kit PoEoC-15K PoEoC-15-HOST PoEoC-15-D Host Unit - PSE Side Device Unit PD Side By using RF technology, this kit can extend the transmission
More informationInstallation And Programming Guide
Installation And Programming Guide BISTRO 2 By NEWCO Enterprises Section 1 Installation Instructions Section 2 Set-Up Programming Instructions Section 3 Service Level Programming Instructions Section 1
More informationModel No. ST60-S (-SRN, -SRK, -DRN, -DRK)
12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrols.com Model No. ST60-S (-SRN, -SRK, -DRN, -DRK) VTR CONTROLLER Sony Protocol USER MANUAL Manual Version.........
More informationOwner's Manual LIGHTING CONTROL CONSOLE TEATRONICS LIGHTING CONTROLS, INC. PROCON II Los Osos Valley Rd., Ste. G Los Osos, CA 93402
Owner's Manual PROCON II LIGHTING CONTROL CONSOLE TEATRONICS LIGHTING CONTROLS, INC. 1236 Los Osos Valley Rd., Ste. G Los Osos, CA 93402 Phone: (805) 528-6900 PROCON II FAX: (805) 528-9345 12/01/94 Page//
More informationGRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle.
GRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle. You will need standard hand tools, a Test Light and a Digital
More informationDD624CS Hi-Def Video Circle & Cross Hair Overlay Generator. Users Manual. Colorado Video
DD624CS Hi-Def Video Circle & Cross Hair Overlay Generator Users Manual Colorado Video WARNING This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance
More informationInstallation and Operation Manual
PROBLEM SOLVED Installation and Operation Manual INC AES DA 2x6 Six-output, two-input AES/EBU Digital Audio Distribution Amplifier Manual update: 9/17/2015 If you need a firmware upgrade, contact Broadcast
More informationDICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating
/A Electronic Signal Data Logger Contents: Product Applications and Useful Features Product Transmitter / DicksonWare Software Product Frequently Asked Questions Warranty / Software & FAQs & Product Applications
More informationModel No. ST60-SPS (-SRN, -SRK, -DRN, -DRK)
12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com Model No. ST60-SPS (-SRN, -SRK, -DRN, -DRK) VTR CONTROLLER Sony Protocol USER MANUAL Table of
More informationSingle Station Waterproof Timer
Single Station Waterproof Timer Installation and Programming Guide Features Up to four irrigation cycles per day Easy installation and programming Battery powered Waterproof and weather resistant 1234
More informationHDMI 1.4 OVER SINGLE CAT5/6/7 EXTENDER WITH BI-DIRECTIONAL IR and RS232 TRANSMITTER & RECEIVER AT-HD4-100SR
User Manual AtlonA HDMI 1.4 OVER SINGLE CAT5/6/7 EXTENDER WITH BI-DIRECTIONAL IR and RS232 TRANSMITTER & RECEIVER AT-HD4-100SR TABLE OF CONTENTS 1. Introduction... 3 2. Package Contents... 3 3. Features...
More informationVGA Extender LR EXT-VGA-141LR. User s Manual
VGA Extender LR EXT-VGA-141LR User s Manual Congratulations on your purchase of the VGA Extender LR. Your complete satisfaction is very important to us. Gefen Gefen delivers innovative, progressive computer
More informationA new generation of access control.
TM A new generation of access control. 2 or 4 Door Expandable Controller INSTALLATION MANUAL Installation overview: Installation Diagram Switch Alpha 4 Alpha 4 + PoE Alpha 4 + PoE Alarm central Accessory
More informationDisplayPort Extender over 2 LC Fibers
DisplayPort Extender over 2 LC Fibers Audio 3GSDI Embedder EXT-DP-CP-2FO User Manual Release A2 DisplayPort Extender over 2 LC Fibers Important Safety Instructions 1. Read these instructions. 2. Keep these
More information