1 R&S SMW200A Release Notes Firmware Version Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, Munich, Germany Phone: Fax: Internet: Subject to change R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. PAD-T-M: /03.00/CI/1/EN Version 30 R&S SMW200A The software makes use of several valuable open source software packages. For information, see the "Open Source Acknowledgment" provided with the product. The following abbreviations are used throughout this document: R&S SMW200A is abbreviated as R&S SMW200A Release Notes Version 30

2 Contents Version Version Version Version Version Version Version Version Version Version Version Version Version Version Version Version Version Version Version Modifications to the Documentation Firmware Update Downgrade Update Information Updating the Firmware Alternative update procedures Firmware update over LAN Firmware update using ISO image Customer Support Release Notes

3 1 Information on the Current Version and History As of version , only signed updates are released in order to make the instruments even more secure. This will make it possible to detect all future unsigned or manipulated updates. The instrument's behavior can also configured via "Setup>Security>Security>>Secure Update Policy". These settings are password protected. For more information, see the R&S SMW User Manual. Through a modified check of the signature, the old releases , and generate the following message during the update process: This message can be ignored, press Ignore. 1.1 Version Released: August 2018 New Options SMW-K143 Cellular IoT Enhancements SMW-K443 Cellular IoT Enhancements (WinIQSIM2) SMW-K298 Modernized GPS, 1 SAT.(WINIQSIM2) SMW-K144 5G NR SMW-K444 5G NR (WinIQSIM2) Release Notes

4 New Functionality / Changed Behavior Modernized User Interface (in line with SMA100B, SMB100B and SMBV100B) :SYSTem:LOCK:REQuest:EXCLusive? and :SYSTem:LOCK:RELease:ALL allow to lock and unlock the instrument for exclusive access over the ethernet Ability to drive pulse modulator directly with marker signal from ARB or Extended Sequencer Bluetooth: enable all advertising packet types for dirty transmitter test Common: Support of Equipment Configuration Viewer Enhanced modulation flatness and image sideband suppression performance for SMW- B13XT. With DACW TAZ6 connectors ADV CLK and ADV TRG are supported for multi instrument issues (instead of Global Connectors) G New Radio Displaying the BWP offset also relative to PointA, not only to the first usable RB of a TxBW Dummy REs are now switched off by default Filter mode replaces filter per BWP switch Increased maximum number of allocations per user and BWP Optionally suppress subcarrier on output center Support for sample rate variation The RF upconverter phase rotation can optionally be included in the baseband signal calculation. Update to 3GPP specifications V15.2.0, V15.2.0, V15.2.0, V Uplink Support for PRACH channel Updated DMRS for transform precoding to recent 3GPP secification EUTRA/LTE All supported features are in line with 3GPP release 14, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v First version to support options K143/K443 (Cellular IoT Enhancements). Changed BCCH-NPDSCH scrambling according to recent specifications. The previous scrambling is still supported in a legacy mode DCI support for NB-IoT with two HARQ processes Improved K81 logging for emtc/nb-iot SIB1 PDSCH: 'LTE Cell' is added to switch the LTE carriers on and off, in NB-IoT Inband Mode Manual Scheduling is supported for NPDSCH in NB-IoT DL PDSCH-SIB1-BR channel is supported for emtc Time Plan is added for PDSCH-SIB1-BR in emtc DL Transport Block Size Indexes are increased from 10 to 13 for Standalone and Guardband modes for NB-IoT. UE Categories M2 and NB2 are added for emtc and NB-IoT Respectively The maximum number of DCI allocations for emtc is increased to Uplink Enhanced DMRS for PUSCH Release Notes

5 NPUSCH Repetitions 2,16,64 are supported for FRCs in NB-IoT Uplink PUSCH Repetitions 12,24 and PUCCH Repetitions 64,128 are supported for emtc Retuning symbols 0,1 and 2 are supported for emtc Sidelink/D2D SRS is supported for emtc Uplink V2X support Widebands of 5MHz and 20MHz are supported for emtc Support of PRACH Restricted Set B Repetitions 4,8,32 are supported for PUCCH Format2 in emtc CEMode B GNSS Added support for GPS-L5, Galileo-E5a and Galileo-E5b signals Routing GNSS streams to the desired output port (RFA, RFB, BBM1 or BBM2) is now managed intuitively in the output streams dialog. This includes automated stream mapper configuration, for example routing the L1 Band to RFA and adding the L2 with L5 Bands on RFB with the correct frequency offsets. Moreover, disabling this automatism is now also possible in order to preserve pre-configured routing upon changing simulation parameters K502 Wideband Ext. Seq RF Power Ramping with Burst Gate Marker now supported in Radar applications Release Notes

6 Fixed Issues 3GPP: incorrect trigger to signal timing for SMW-B9 option Added support for marker output on TMC connectors. This release has a fixed mapping: baseband marker 1 is output on TMC 1/3 and marker 2 on TMC 2/ Amplitude modulation clipping at 100% modulation depth Baseband marker output disabled with active envelope tracking DVB-S2 and DVB-S2X did not correctly work with data lists DVB-S2X: VL-SNR mode not working correctly Hardware missing error message appears, if SMW-K18 is not installed IEEE , for b CCK mode only: single trigger sequence length was slightly too short for longer sequences - MAC header sequence control did not increment per frame - signal was incorrect for data length > 1024 bytes with FCS enabled Incorrect trigger to signal timing for sample rates < 300kHz Noise generator source for analog AM/FM/PhiM not working Phase offset from I/Q Stream Mapper not working Phases between baseband streams not aligned with active baseband frequency offset Pulse generator sync output not working with pulse delay values between 10 ns and 55 ns Simultaneously loading multi segment waveforms to several ARBs occasionally not working correctly SMW-B9: incorrect LF generator frequency for advanced mode SMW-B9: residual DC offset for LF generator output in advanced mode SMW-K80 BERT: Incorrect configuration of threshold voltage for user 4-6 connectors Waveform files transferred by SCPI may be clipped to 64MSamples or 256MByte due to unintended internal limitation G New Radio Issue for PDCCH DMRS in case of interleaved CCE-to-REG mapping PBCH payload size has to be 32 bits but is only 31 bits Displayed playback rate is not always correct Issue for multi numerology scenarios Issue when using long ARB sequences Issues with overlapping allocations and different numerologies PDSCH/PUSCH bit mapping issue SCPI bug for PDSCH/PUSCH DMRS config type Slightly different PEP on different instruments Test model name is shown even after changing parameters Trigger delay does not work if unit "time" is used. Also, shown "Actual trigger delay" is wrong Visual update problems in the time plan Uplink Issue for BPSK Issue for PUSCH RB number, if transform precoding is enabled Issue with exemplary test model for transmit precoding EUTRA/LTE emtc PBCH is not correctly drawn in the time plan (not a signal issue) Issue for certain emtc PDSCH allocations Issue with SIB1-NB data sources of NB-IoT Issue with SIB1-NB scheduling repetitions Release Notes

7 Minor issue for DCI when DMRS Alternative Table is used The OCC sequence is wrong if the case of single AP transmission The OCC sequence is wrong if the DMRS alternative table is activated When Puncturing is switched on, LTE CRS signals are erroneously punctured in the NB-IoT Inband Mode The mapping of CRS is not correct in case of PBCH repetitions The precoding of the PDCCH region in case of a partial starting subframe is wrong The range of the field "HARQ Process number" in DCI Format 6-1A is wrong Changing the filter settings does not affect the signal in some cases Test Case Wizard The carrier power is wrong in Test Case Wizard (8.3.1, 8.3.7, 8.3.8) Uplink GUI issue for emtc start subframe Issue for slot numbers for FRCs for NB-IoT Minor issue in GUI The mapping of SRS is wrong when 4 SRS Combs are configured The power leveling is wrong in case of longer UpPTS for SRS UE Burst RMS Power doesn't work for PUCCH F4 and F GNSS Incorrect AWGN C/N in some cases Unwanted pseudo-range systematic bias of up to 2 meters is now removed The speed limit of 600 m/s for the B10 boards is now corrected. The issue lead to limiting the speed to 300 m/s instead Misalignment between RF signals, Trigger and Marker are now removed A channel budget issue when more than 24 channels are used and a new SV rises is solved. The error 'Value out of Range' upon first changing of the ref. power while the simulation is running is now fixed. The error Navigation Data FIFO underrun happening in certain configurations is now solved. Importing BeiDou, Galileo and GLONASS Alamanac files now disables not present SVs. This worked well previously only for GPS. fixed issues that happened while the simulation is running then changing the number of Baseband sources in advanced GNSS (K120), in the output stream dialog, Corrected wrong units in the orbit parameter display: Radian vs. Semicircles Radar Echo Generation Remote Connection to R&S-FSW via USB in External RF and I/Q Dialog not always working correctly K503 Realtime Ctrl. I/F Waveform list sometimes empty Release Notes

8 Known Issues ARB Waveforms are limited to 512MSamples Bugfix for pulse generator external gated mode In some rare cases while compensating frequency responses with high dynamic ranges ( > 15 db) and using ALC setting Sample & Hold, the absolute level compensation may have an additional level error. K19: HS DIG I/Q (40G/50G) connection via connector BBMM2 is instable in System Config Mode Standard and Advanced Wideband baseband: corrupted output of binary control lists at sequence end in some cases Wideband SMW, GSM: level at slot 8 for levatt 7 value is wrong Fading: The geometry-based SCM model is not emulating the channel properly OneWeb OneWeb Reference Signals, Querying the available reference signals by means of SCPI does not work EUTRA/LTE Test Case Wizard Uplink The Autofill feature for PDSCH scheduling mode Auto Sequence is not available for TDD duplexing mode. Improved On/Off ratio for TDD is not supported in combination with Best ACP or Auto filter optimization types Time plan windowing is not working correctly for emtc/nb-iot Home BS test cases ( , 6.2.7, 6.2.8) are not available in the test case wizard Test Case 8.2.1A is not available in the test case wizard NB-IoT and emtc data sources do not restart every transmission bundle even if restart data flag is not set. Real-time feedback is not supported for uplink MIMO and uplink carrier aggregation GNSS Carrier phase is not simulated correctly. Code phase is working properly. SBAS Generate Correction Data Automatically does not correctly sync with the simulated ionosphere and GPS orbit/clock errors leading to an error of few meters in the position calculated by the receiver when using the SBAS correction service. Instead the Replay Historical Data and Sync Atmosphere & SV errors can be used at the moment. HiL instabilities with system latency higher than 30 ms. Moreover this issue only exists when the streaming rates are slower than 50Hz. SV relative power offset might lead to an increased noise component in the signal spectrum when more than one baseband sources are combined for the given GNSS stream. It is recommended to use 1 baseband source per GNSS stream for sensitivity testing. in Re-trigger modes turning ON a SV on-the-fly followed by a trigger will lead to an inconsistent signal from that SV. The body mask and antenna pattern editors have assume a flipped direction of the z-axis Inconsistencies in the navigation data might cause some GNSS receivers to invalidate the signal of certain SVs for few seconds. Unwanted behavior when changing the start simulation time after importing constellation files (YUMA, RINEX, AGL etc.). It is recommended to change the time first if an import is needed Release Notes

9 Importing GLONASS Rinex does not synchronize Almanac data. It is recommended to work with AGL files Unwanted behavior when importing RINEX files for BeiDou, QZSS and GLONASS. It is recommended to work with YUMA and AGL formats instead Radar Echo Generation After changes on analyzer, latency is not reduced to minimum. Workaround: turn BB Input off and on again For 24 Moving Objects with different velocity after some minutes DSP- Error 0x8004 is observed For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again For signal routing BBin to REG A+B and Stream A mapped to RF B in Stream Mapper, signal generation not working in all cases For signal routing to both REGs and addition in Stream Mapper, Automatic System Latency measurement not working in all cases K503 Realtime Ctrl. I/F K503 Realtime Ctrl. I/F: Automatically applied Trigger Mode settings in Multi Instrument mode across basebands might be inconsistent K503 Realtime Ctrl. I/F: Marker of first pulse is sometimes missing K503 Realtime Ctrl. I/F: PDW Streaming before triggering causes loss of PDWs Release Notes

10 1.2 Version As of this version, only signed updates will be released in order to make the instruments even more secure. This will make it possible to detect all future unsigned or manipulated updates. The instrument's behavior can also configured via "Setup>Security>Security>>Secure Update Policy". These settings are password protected. For more information, see the R&S SMW User Manual. Through a modified check of the signature, the releases , and generate the following message during the update process: This message can be ignored, press Ignore. Released: April 2018 New Options SMW-K80: Bit Error Rate Tester SMW-K109: GNSS Real Time Interfaces SMW-K504: Realtime Contr. I/F EDR SMW-K525: Baseband Ext. to 1GHz BW SMW-K527: Baseband Ext. to 2GHz BW SMW-K414: OFDM Signal Generation (WinIQSim2) New Functionality / Changed Behavior Added phase offset parameter to digital impairments Extended Sequencer: mode Real Time Control Interface does not require SMW- K300/K301 options anymore Improved accuracy of marker to baseband signal timing for B9 option New ARB feature: RF Power Ramping with Burst Gate Marker to control the RF pulse modulator with the burst gate marker of the waveform file Release Notes

11 SMW-B10F added. This Hardware option is needed to allow the simulation of GNSS scenarios with user motion above 600 m/s. The SMW-B10F includes additionally all the functionality of SMW-B Graphics to visualize frequency range of all files and complex frequency response of all active concatenated files Error History Query: Reading the error history with :SYSTem:ERRor:HISTory? is deprecated. Instead use :SYSTem:ERRor:GNEXt? which returns the errors from a global error queue, not related to the scpi connections Starting with this version, it is not possibly any more to list the samba shares of the instrument without logging in as user "instrument" OneWeb Reference Signals, Reverse Link Added several new multi carrier files for reverse link User-Defined Signal Generation, Option SMW-K130 is renamed to OneWeb User-Defined Signal Generation Option SMW-K430 is renamed to OneWeb User-Defined Signal Generation with R&S WinIQSIM EUTRA/LTE For some system configurations in Advanced mode, upsampling 1 is used instead of NPBCH scrambling symbol rotation supported according to recent 3GPP specifications Alternative table for DMRS (Rel. 13) and semi open loop (Rel. 14) The EPDCCH is mapped to a valid candidate also when a limited number of configurable subframes is used Special subframe configuration 10 in downlink and uplink and PUSCH in special subframe Option K81 is renamed to LTE/5G logfile generation Uplink Support for 8 configurable users Uplink Extra UE delays can be configured Uplink SRS enhancements for Rel Uplink Realtime Feedback can now be used in coupled mode GNSS Hardware in the Loop (HiL) simulation is now supported with option SMW-K109. Supports both TCP/SCPI and UDP/RAW Up to 4 GNSS streams (i.e. unique combinations of Vehicle/Antenna/RFband) are now supported. This includes automatic connectivity and configuration of up to four RF outputs (two internal RFs and two external SGT100A) Speeds over 600m/s now supported with the B10F hardware option Automated calculation of output level is now available when adding GNSS in the stream mapper with other signals, such ARB or other standards Anti-Spoofing Flag in the GPS/LNAV navigation Message is now configurable Antenna position offsets added in the User Motion Log Monitoring View HW Channels is now available to visualize individual signal assignment in the HW Satellite position change is now updated on the ground tracks view while the simulation is running Static Multi-path now works with multiple antennas Release Notes

12 V5GTF Removed default DCI entry from downlink predefined configurations Uplink LDPC Channel Coding for xpusch Uplink parameters are configurable OFDM Signal Generation Increased maximum occupied number of subcarriers to 0.83 of FFT size Increased number of allocations to Introduced 'Reserved' as content type (affects K96 XML file generation) Minimum total number of subcarriers (FFT size) of 64 is supported Now a waveform playback option SMW-K414 is available in addition to SMW-K114 internal option. Waveforms geneated by means of Generate WV functionality of the former 5G Air Interface Candidates digital standard can still be played back if either SMW-K114 or SMW-K414 is installed Modulation type OFDM, also set as a new default Renamed digital standard to OFDM Signal Generation Custom Digital Modulation Added 512 and 2048 QAM modulations Added support for external data input on B9 option K502 Wideband Ext. Seq Added definable PDW marker flags for each pulse K503 Realtime Ctrl. I/F Added definable PDW marker flags for each pulse Added UDP protocol for optimized latency in HIL applications Increased maximum PDW rate for ARB waveforms from 600kPDWs to 800kPDWs Release Notes

13 Fixed Issues A problem with the indication of ethernet connections in the taskbar was solved. An error in a driver could lead to a deadlock when ftp connections to the instrument were opened and closed repeatedly Baseband Freq Offset in Advanced-Mode abs max value to large (only SMW-B9) BBin Peak Level < dBFS not working correctly (only SMW-B10) Creating multisegment waveform files with a high number of segments External inhibit in advanced coupled baseband modes Incorrect output of binary control list markers with B9 option Issues with very low peak levels in waveform files For some configurations of SMW equipped with SMW-B13XT, the phase compensation of SMW-K544 in channel RF B is not working Increased range of crestfactor setting to 80dB Main panel not ok if no fader or awgn is available (missing connection lines, optical problem only) Radar Echo Generator: No signal if REG A is routed to RF B Save / Recall does not work for IEEE Save/Recall in Fading Block in combination with Customized Dynamic Fading can provoke uncritical database error - (IdPDbFadGeoBAntColTx) OFDM Signal Generation Timeplan displays allocations not according their actual priority OneWeb User-Defined Signal Generation, Uplink Issue with DMRS for PUACH User-Defined Signal Generation, Uplink Physical cell ID group and physical layer ID are shown User-Defined Signal Generation, Issue for some SCPI commands EUTRA/LTE MIB-NB is wrong after 64 frames MPDCCH cannot be generated with more than one repetition SFN Restart Period 3GPP (1024 Frames) does not work in some advanced system configurations The Codeword Swap Flag leads to no allocation when active for DCI 2/2A The EPDCCH REs are mapped onto CSI-RS REs The subframes outside a LAA Burst are filled with Dummy Data The TBS is not correctly determined in case of Transmit Diversity for DCI 2/2A The transport block size in case of 33A is wrong When changing the LTE puncturing for NB-IoT, the signal is not updated reliably emtc cannot be configured with extended cyclic prefix Erroneous user interface behavior when switching the duplexing mode in emtc or NB-IoT Release Notes

14 In case of 20 MHz LTE channel BW played on B9 SMW in mode Digital Only (HS), one has to manually switch the filter to Best EVM no upsampling Issue for some NB-IoT transport block sizes Incorrect waveform when time domain windowing with certain types of baseband filters are enabled Uplink Filename misalignment for PUSCH logging with option K Uplink Minor GUI issue of the user antenna port mapping Uplink Minor issue in GUI for bit information Uplink Minor issue in SCPI return parameters for 256QAM FRCs Uplink Uplink Realtime feedback cannot always be configured if option K115 is present but not option K SCPI issue of the power offsets in th UE antenna port table in advanced system configurations Uplink Sporadic crashes when using uplink realtime feedback debug reports Uplink The PRACH signal is wrong for some specific configurations Uplink The scrambling is wrong in case of CE Mode B Uplink The SRS on the SCells cannot be configured for more than one frame Uplink UE release selector is not functional on specific instrument (option) configurations GNSS Extension to 48 channels with SMW-K99 available. Up to 144 Channels also available in combination with SMW-K AWGN Block in advanced GNSS works now in coupled mode also stabilization of the Advanced GNSS mode (SMW-K120) Issues starting the GNSS signal the first time after SMW reboots are now solved Satellite states changed by user, won t be overwritten when simulation restarts, unless Time or Position change The initial constellation is now recovered after GNSS was running for some time and then switched OFF The minimum or maximum number of SVs can now be set in tracking mode V5GTF Possible crash when configuring the user settings in basebands B, C or D Second AP of multi-ap xpdsch-dmrs is not mapped (Spatial Multiplexing) Uplink xpusch PN-datasource is not set back correctly K503 Realtime Ctrl. I/F K502 Wideband Ext. Seq Added socket status flag Sporadically no IP adress was obtained Fixed potential DSP deadlocks when obtaining an IP adress Fixed the reset time SCPI behavior. It could happen, that parts of a PDW where lost, causing random behavior Fixed potential memory corruption after changing the sequencer file Known Issues Release Notes

15 In some rare cases while compensating frequency responses with high dynamic ranges ( > 15 db) and using ALC setting Sample & Hold, the absolute level compensation may have an additional level error Main panel: connection lines missing if no fading and no AWGN is installed OneWeb Reference Signals: Querying the available reference signals by means of SCPI does not work Wideband SMW, GSM: level at slot 8 for levatt 7 value is wrong EUTRA/LTE Minor issue for the timeplan in case of LAA The Autofill feature for PDSCH scheduling mode Auto Sequence is not available for TDD duplexing mode Improved On/Off ratio for TDD is not supported in combination with Best ACP or Auto filter optimization types Time plan windowing is not working correctly for emtc/nb-iot Test Case Wizard Home BS test cases ( , 6.2.7, 6.2.8) are not available in the test case wizard Test Case Wizard Test Case 8.2.1A is not available in the test case wizard Uplink Uplink NB-IoT and emtc data sources do not restart every transmission bundle even if restart data flag is not set Real-time feedback is not supported for uplink MIMO and uplink carrier aggregation GNSS Unwanted pseudo-range systematic bias of up to 2 meters SV relative power offset might lead to an increased noise component in the signal spectrum when more than one baseband sources are combined for the given GNSS stream. It is recommended to use 1 baseband source per GNSS stream for sensitivity testing HiL instabilities with system latency higher than 30 ms. Moreover this issue only exists when the streaming rates are slower than 50Hz HiL Mode-B SCPI command shows instability in the simulated position. It is recommended to use Mode-A SCPI or UDP instead Importing GLONASS Rinex does not synchronize Almanac data. It is recommended to work with AGL files Misalignment of few milliseconds between 1PPS markers and the GNSS signals.the signal is delayed by us from expected absolute time.the marker is around 1.5 ms advanced from expected absolute time SBAS Generate Correction Data Automatically does not correctly sync to the pseudorange error profiles. Instead the Replay Historical Data and Sync Atmosphere & SV errors can be used at the moment Unwanted behavior when importing RINEX files for BeiDou, QZSS and GLONASS. It is recommended to work with YUMA and AGL formats instead Unwanted behavior when changing the start simulation time after importing constellation files (YUMA, RINEX, AGL etc.). It is recommended to change the time first if an import is needed The first changing of the ref. power while the simulation is running, might show the error 'Value out of Range'. This simulated power correct In advanced GNSS (K120), in the output stream dialog, changing the number of Baseband sources while the simulation is running, could lead to errors. It is recommended to stop the simulation before performing this change, then start it again Release Notes

16 Radar Echo Generation K503 Realtime Ctrl. I/F K502 Wideband Ext. Seq Devices with exactly two B14 options have wrong output stream assignment After changes on analyzer, latency is not reduced to minimum. Workaround: turn BB Input off and on again For 24 Moving Objects with different velocity after some minutes DSP- Error 0x8004 is observed For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again For signal routing BBin to REG A+B and Stream A mapped to RF B in Stream Mapper, signal generation not working in all cases For signal routing to both REGs and addition in Stream Mapper, Automatic System Latency measurement not working in all cases Object Configuration -> Object Hold Off not available Object Configuration -> Type = Moving -> Simulation Mode = One Way or Cyclic not available Object Preview -> Live Preview not available Remote Connection to R&S-FSW via USB in External RF and I/Q Dialog not always working correctly Falling edge of triangular chirp is currently errornous Falling edge of triangular chirp is currently errornous Release Notes

17 1.3 Version Released: December 2017 New Options SMW-K19: WB digital baseb. output SMW-K130: OneWeb SMW-K430: OneWeb WinIQSIM2 SMW-K552: Custom dig. baseb. conn. New Functionality / Changed Behavior DVB-S2/S2X option K116: Added new feature to alternate MODCOD in ACM mode with up to 100 different settings. Multiple entities option SMW-K76: on instruments with wideband baseband (SMW-B9, SMW-B13XT) DACW is required OneWeb EUTRA/LTE First version to support OneWeb K130/K430 options. The corresponding firmware extension needs to be installed on the instrument in order to be able to use OneWeb K130 or K430. Please ask your local sales contact or customer support for details. From this firmware version on, the corresponding firmware extension needs to be installed on the instrument in order to be able to use OneWeb K355. Please ask your local sales contact or customer support for details Compatibility Information: All supported features are in line with 3GPP release 14, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/-K105). Guardband NB-IoT carrier can be shifted in frequency completely flexibly. Improved filtering for NB-IoT standalone (200 khz channel bandwidth), causing a better EVM and ACP Uplink Extended range of I_HARQ_offset Uplink PUCCH formats 4 and Uplink Updated the FRC usability feature according to recent versions of 3GPP TS Uplink FRCs for NB-IoT Uplink PUSCH can be set to UCI only mode per subframe, by means of USH TB size CSI-RS for FD-MIMO/eFD-MIMO EPDCCH logging for K81 log file generation Functional improvements and user interface improvements for downlink emtc. Additional power reference mode in case of NB-IoT standalone downlink 200 khz channel bandwidth for easier leveling on the active signal parts By default, no emtc / NB-IoT DCIs are configured after preset Content coding for NB-IoT SIB1-NB Displaying RS power per RE relative to level display also for NB-IoT standalone 200 khz channel bandwidth case Release Notes

18 Enabling of MCS table 2 and Alt. TBS index can be done per cell For combinations of LTE with NB-IoT in inband mode, the LTE carrier can be punctured. Needed for test model configurations from 3GPP TS NB-IoT NPBCH is configurable flexibly in case of MIB encoding is switched off New UE categories according to recent versions of the specification Support for NPDSCH data source type data list Test models (N-TM) for NB-IoT View modes PRB/VRB for TDD G Air Interface Candidates Error message with allocation number is shown if custom IQ file cannot be not found Support for content type Pilot f-ofdm A VSE-K96 xml-settingsfile is automatically exported to K114 directory in the shared folder f-ofdm Increased the maximum number of symbols to V5GTF Adjustable number of symbols for xpdcch Coupled modes for up to eight baseband outputs Precoding type selection for channels xpbch (Tx diversity), xpdcch (Tx diversity), xpdsch (Tx diversity + spatial multiplexing) xpdcch encoding with DCI formats A1/A2/B1/B Uplink Uplink Custom Digital Modulation Radar Echo Generation AutoDCI mode, which automatically generates xpdsch/csi-rs allocations from xpdcch-xregs/cces. In predefined configuration Uplink_Config_2, n_xpucch^2 is 8 so that xpucch is positioned at PRBs# In predefined configuration Uplink_Config_2, xpucch-dmrs power is changed to 0dB Added new modulations 8FSK, 16FSK, 32FSK and 64FSK Added support for DVB-S2 modulations 16APSK and 32APSK Increased max. Object Velocity for Object Type "Moving": 1500 m/s Release Notes

19 Fixed Issues Internal BB frequency correction for devices equipped with ASATT13 working properly Custom Digital Modulation: Occasionally appearing error Baseband level measurement failed K501/K502: Single trigger option was not available for Master/Slave mode K502\K503: Relative phase settings, indicated by PHASE_MOD control bit, did not work Extended Sequencer: error reported by recall settings from archives (missing file *.ps_adr) Firmware runs out of memory and crashes if dialog Remote Access is open for some minutes IEEE : Fixed incorrect error message when setting unsupported parameters with SCPI IEEE ax: Modified SCPI commands for SIG-B DCM and SIG-B MCS Memory leak if ARB state is on MIMO 8x8: Changing subset via SAV/RCL does not work Output delay of digital outputs between SMW-B13(T)/K18 and SMW-B14 together with SMW-K74, -K75, -K76 adjusted. Establishing multiple remote connections during execution of a *RST potentially locks the instrument GNSS Various issues in recalling saved scenarios EUTRA/LTE Exchange of satellites while simulation is running causes large pseudo-range errors, causing receivers to lose the position fix after long simulation time Changing the ref power on-the-fly causes inconsistencies, not all changes take place. No signal after rebooting the machine and starting GNSS on baseband B. Toggling the state of baseband B leads to the generation of a valid signal. The initial constellation is not recovered after GNSS was running for some time and then switched OFF Carrier aggregation frequency shift range is wrong on SMW with B9 but without K526 option Uplink USH UCI channel coding is wrong in case of more than 22 bits Uplink Configurable range of SRS configuration is wrong Uplink Uplink Uplink If more than one NB-IoT transmission is configured in the NB-IoT table, some of them do not use channel coding although channel coding is enabled in the user interface. Recalling SRS settings from older firmware versions into more recent ones does not work reliably. The signal is not recalculated after changing only the VRB offset in the user interface AutoDCI for format 2/2A/2B/2C/2D does not work correctly if TB1 is disabled Auto-filled values in the antenna port mapping tables can be wrong in some configurations DCI field length is sometimes incorrect in case of EPDCCH DCI RBA content for emtc is incorrect EPDCCH DMRS is incorrectly mapped to antenna ports Firmware stability issue Minor GUI issue for user antenna mapping in case of EPDCCH Minor GUI issue in allocations' antenna port tables Release Notes

20 Minor GUI issue in DCI configuration The parameter Starting Symbol is not taken into account for emtc MPDCCH. User antenna port mapping is not configurable in case of EPDCCH with TM9/10. CC-RNTI DCI1C cannot be configured reliably for cross carrier scheduling cases Channel coding issue in case of 5 or 7 layers For DRS on carriers in LAA mode, the K113 option is incorrectly required IR soft buffer calculation fails in cases with different Tx modes in different cells and configured UE category LAA bursts can be configured in an overlapping way LAA can not be configured without K113 option NB-IoT antenna port mapping does not work reliably in case of coupled system configuration Recalling emtc allocations from save/recall files does not work reliably Simulated antenna parameter is visible in coupled system configurations, where it is not used at all Stability issues when configuring MBSFN Timeplan for emtc downlink cases is not supported TxMode 9 antenna port configuration save/recall does not work for emtc G Air Interface Candidates Maximum value for cyclic prefix is not the maximum value of total number of subcarriers (FFT Size). Alternative cyclic prefix is not limited to maximum value of total number of subcarriers (FFT Size) Relative power for user-specific and custom IQ allocations has no effect Timeplan does not consider alternative cyclic prefix for time-axis OneWeb Markers are not working correctly V5GTF If only one DL PCRS AP is active, xpdsch is mapped to resource elements of the inactive DL PCRS AP N_ID^PCRS/DMRS is used incorrectly Known Issues Fill User Correction Data With Sensor does not work in Path B Baseband Freq Offset in Advanced-Mode abs max value to large (only SMW-B9) BBin Peak Level < dBFS not working correctly (only SMW-B10) Save/Recall in Fading Block in combination with Customized Dynamic Fading can provoke uncritical " database error - (IdPDbFadGeoBAntColTx)" GNSS The extension to 48 channels with option K99 is not fully supported yet. Only 36 Channels are possible Release Notes

21 Extension to 4 output streams with option K120 is not yet supported. Only 2 streams are possible Unwanted pseudo-range systematic bias of up to 2 meters GNSS receivers would not track GLONASS and Galileo satellites that become visible after simulation start due to inconsistent navigation data. With GLONASS, these incoming satellites may additionally lead to simulation abortion with errors. Inconsistent power level when adding GNSS to other standards in the stream mapper. Automatic powering does not work in case the device ins configured with two baseband paths and one RF board EUTRA/LTE Changing the start simulation time can lead to divergence between almanac and ephemeris data. This happens typically for large changes in the order of 3 months or more. Unwanted behavior when changing the start simulation time after importing constellation files (YUMA, RINEX, AGL etc.). It is recommended to change the time first if an import is needed. Unwanted behavior when importing RINEX files for BeiDou, QZSS and GLONASS. It is recommended to work with YUMA and AGL formats instead. Misalignment of few milliseconds between 1PPS markers and the GNSS signals. Inconsistent behavior in automatic generation of SBAS correction data from pseudo-range error profiles. Improved On/Off ratio for TDD is not supported in combination with "Best ACP" or "Auto" filter optimization types. In case of 20 MHz LTE channel BW played on B9 SMW in mode "Digital Only (HS)", one has to manually switch the filter to "Best EVM no upsampling" , , Time plan windowing is not working correctly for emtc/nb-iot Uplink Uplink The "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not available for TDD duplexing mode. NB-IoT and emtc data sources do not restart every transmission bundle even if "restart data" flag is not set. Real-time feedback is not supported for uplink MIMO and uplink carrier aggregation Uplink Sporadic crashes when using uplink realtime feedback debug reports Test Case Wizard Test Case Wizard Home BS test cases ( , 6.2.7, 6.2.8) are not available in the test case wizard Test Case 8.2.1A is not available in the test case wizard Radar Echo Generation For signal routing to both REGs and addition in Stream Mapper, Automatic System Latency measurement not working in all cases. For signal routing BBin to REG A+B and Stream A mapped to RF B in Stream Mapper, signal generation not working in all cases After changes on analyzer, latency is not reduced to minimum. Workaround: turn BB Input off and on again For 24 Moving Objects with different velocity after some minutes DSP-Error 0x8004 is observed Release Notes

22 For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again Object Configuration -> Type = Moving -> Simulation Mode = One Way or Cyclic not available Object Configuration -> Object Hold Off not available Object Preview -> Live Preview not available K502 Wideband Ext. Seq. / K503 Realtime Ctrl. I/F Sporadic failure of obtaining an IP address on LAN interface after reconfiguration. Switching to another standard and back to K503 solves the problem The maximum achievable PDW rate in ARB mode is currently 666 kpdw/s. Please avoid using ARB snipplets shorter than 1.5 us , Release Notes

23 1.4 Version Released: August 2017 New Options SMW-K503: Realtime Ctrl. I/F SMW-K544: User-Def. FR Correction SMW-K821: MIMO subsets New Functionality / Changed Behavior Clock synchronization to NTP time server available , , SMW-K61: maximum number of carriers increased to User defined compensation bandwidth available EUTRA/LTE Compatibility Information: All supported features are in line with 3GPP release 14, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/-K105) Default value of link direction is now downlink also on instruments with K115 and without K55 option Configurable range of carrier power was extended Alternative TBS indices Enhancements to CSI-RS according to recent releases of the LTE specifications (discovery reference symbols). Enhancements to CSI-RS according to recent releases of the LTE specifications (multiple cells) Support for emtc downlink signals as part of K Uplink 5G Air Interface Candidates V5GTF Serial HARQ feedback for NB-IoT NPUSCH format 1and emtc PUSCH closed loop performance tests Increased maximum number of subcarriers Added dynamic cyclic prefixes (f-ofdm) Added dynamic cyclic prefixes (f-ofdm) User-defined filter extended for complex-valued coefficients (f-ofdm) Added "none" option as filter type (f-ofdm). Increased maximum number of allocations to signal generation with flexible configuration Release Notes

24 Fixed Issues Baseband signal routing (B->A) in special configurations not available via GUI SCPI command :SOURce2:BB:TETRa:STATe ON causing restart EUTRA/LTE After recall, the NB-IoT DCI parameters were sometimes wrong Correction for DCI format 0 in case of transmission mode Correction for DCI format 2D in case of TDD and 20 MHz channel bandwidth Correction for LAA modulation orders in case of incomplete subframes Fixed channel power in case of NB-IoT transmit diversity Fixed DCI format 1C auto generation in case of LAA Fixed EPDCCH-DMRS for Extended Cyclic Prefix Fixed EPDCCH-DMRS for AP109 in case of distributed transmission type. Fixed save/recall for NB-IoT channel coding settings Fixes for CSI-RS in case of extended CP or LAA For NB-IoT, sometimes the allocation table was not correctly updated after reconfiguring a DCI LAA could not be configured without K113 option LTE Dummy data (if configured) could interfere with NB-IoT inband users Minor fix for UE-specific RS with Extended CP PDCCH was sometimes shown to be active in the user interface although standalone NB-IoT was configured PDSCH CRC check failed in some cases for non-user DCIs Sometimes the PDSCH scheduling mode "Auto Sequence" was not configurable Sporadic crash if DCIs are configured for EPDCCH Stability improvements for MBSFN The DCI format 1C content was wrong in Auto Mode for LAA The number of physical bits was sometimes wrong for PDSCH The transport block size was wrong in AutoDci mode for cases where one codeword was mapped to three or four layers User interface improvements for NB-IoT Fix for user-defined filters Test Case Wizard On instruments with K115 but without K415 it was not possible to play back K415 waveform files The test case wizard did not set the link direction anymore Uplink After recall, the NB-IoT NPUSCH parameters were sometimes wrong Uplink Correction for NPUSCH DMRS in case of 3.75 khz subcarrier spacing and long repetitions Uplink Fix for uplink NB-IoT in case of more than one activated user Uplink Sporadic crash in case a lot of NB-IoT transmissions have been configured. Uplink Fixed calculation error in case of NB-IoT and more than one configured user Uplink Fixed sporadic crashes when using uplink feedback debug reports Uplink Signal quality improvement for NB-IoT NPRACH Uplink Sporadic crash when configuring NB-IoT uplink signals Uplink Sporadically there was a mismatch of SRS Subframe Configuration in the Carrier Aggregation PCell settings and the node settings Uplink Updates and minor corrections for TDD FRCs Uplink Recalling uplink settings from older firmware versions into more recent ones did not work reliably Release Notes

25 5G Air Interface Candidates OneWeb V5GTF Increased precision for subcarrier spacing parameter Fixed wrap-around of filtering (f-ofdm) Marker configuration has not been stored correctly in OneWeb waveform files Filtering was improved for a better EVM Uplink Power of xpdsch-dmrs increased by +6dB. Power of xpusch-dmrs increased by +6dB. Uplink Fixed xpusch-dmrs when RB offset is set >0. Uplink Blanked DL Sync subframes 0 and 25. No meaningful configuration was set after preset, resulting in an error message if signal was switched on without further configuration. Without an installed K55 option, the V5GTF scenarios were not shown in the user interface correctly Known Issues Multi instrument mode: Increased timing jitter between instruments equipped with B13XT wideband hardware option SMU remote compatibility: :SOURce1:IQ:GAIN and :SOURce1:BB:IQGain, 3dB settings lead to 2dB settings Dialog Remote Access causing crash when kept open No signal generated when User Filter is configured with Custom Digital Modulation on wideband SMW EUTRA/LTE Improved On/Off ratio for TDD is not supported in combination with "Best ACP" or "Auto" filter optimization types. The "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode Timeplan for emtc downlink cases is not yet supported Uplink Test Case Wizard Test Case Wizard Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation. Home BS test cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard Test Case 8.2.1A is not yet available in the test case wizard K78 Radar Echo Generation For signal routing to both REGs and addition in Stream Mapper, Automatic System Latency measurement not working in all cases , , After changes on analyzer, latency is not reduced to minimum. Workaround: turn BB Input off and on again. For 24 Moving Objects with different velocity after some minutes DSP-Error 0x8004 is observed For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases Release Notes

26 For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again. Object Configuration -> Type = Moving -> Simulation Mode = One Way or Cyclic not available K503 Realtime Ctrl. I/F Object Configuration -> Object Hold Off not available Object Preview -> Live Preview not available The flag to indicate if value in the PHS field inside the PDW body is absolute or relative to the previous phase value in the last PDW is not functional. The phase value is always assumed absolute and not relative to the last PDW Sporadic failure of obtaining an IP address on LAN interface after reconfiguration. Switching to another standard and back to K503 solves the problem. The maximum achievable PDW rate in ARB mode is currently 666 kpdw/s. Please avoid using ARB snippets shorter than 1.5 us FREQ_INC used by Real-Time PDWs in Frequency Increment - FMCW mode may cause errors at low values around 1 KHz Release Notes

27 1.5 Version Released: April 2017 New Options SMW-K117/417: Bluetooth 5.0 SMW-K118/K418: Verizon 5GTF Signals SMW-K119/K419: LTE Release 13/14 (available from May 2017) SMW-K142/K442: IEEE ax SMW-K355: OneWeb Reference Signals New Options (first time available with B9) SMW-K40: GSM/EDGE SMW-K41: EDGE+ SMW-K502: Wideband Ext. Sequencing SMW-K540: Envelope Tracking SMW-K541: Digital Predistortion New Functionality IP Address is displayed on main screen IDN String: version info has been shortened. Old: <main version>-<r&s Espresso version> New: <main version> In case of troubles with this new format, go to Remote Access / Instrument Emulations and switch to user defined *IDN? Identification. Then press Set to default and adapt the IDN String EUTRA/LTE All supported features are in line with 3GPP release 14, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/-K105). DRS for downlink LAA as part of options K119/K419 (available from May 2017). Release 13 downlink LAA (frame structure type 3) as part of options K119/K419 (available from May 2017). Support for downlink NB-IoT (Cat-NB1). Uplink Release 14 uplink 256QAM as part of options K119/K419 (available from May 2017). MBSFN can be enabled in PDSCH scheduling mode "Auto/DCI". K78 OTA Range Offset now m Release Notes

28 Restart Synchronization for both REG blocks Fixed Issues FREQ:RCL EXCL not working properly with SZU100A K820: Positioning menu for file load in Filename NRP-Z57 not working properly with SZU100A B13XT/AWGN noise only : baseband has to be switched on EUTRA/LTE Minor CRS fix for TDD special subframe config Minor fix for CRS reservation in case of TDD Minor fixes in the user interface , , , , , , Uplink Bugfix for NB-IoT NPRACH in case of many repetitions Uplink Bugfix for NB-IoT NPUSCH Uplink Bugfix for power reference mode UL Burst in case of SRS-only signals Uplink Calculation aborted for NB-IoT NPUSCH format 2 with 3.75 khz subcarrier spacing Uplink emtc retuning gaps could happen under rare circumstances even with hopping switched off Uplink Fix for emtc uplink repetitions in case of TDD Uplink Fix for NB-IoT NPUSCH in case of more than one configured transmission bundle , Uplink Fixed possible crash for large number of emtc PRACH preamble attempts Uplink Minor fixes in the user interface , , , , , Release Notes

29 Uplink NB-IoT users 2,3 and 4 did not work Test Case Wizard Minor fixes in the user interface Known Issues List mode, channel B: With B212/B220 and I/Q setting only working in live mode The execution time of the internal adjustment is too long Custom Digital Modulation: control lists are not supported EUTRA/LTE Improved On/Off ratio for TDD is not supported in combination with "Best ACP" or "Auto" filter optimization types The "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode Uplink Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation Test Case Wizard Home BS test cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard Test Case Wizard Test Case 8.2.1A is not yet available in the test case wizard K78 For signal routing to both REGs and addition in Stream Mapper, Automatic System Latency measurement not working in all cases. After changes on analyzer, latency is not reduced to minimum. Workaround: turn BB Input off and on again , , After changes on analyzer, latency is not reduced to minimum. Workaround: turn BB Input off and on again For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again Object Configuration -> Type = Moving -> Simulation Mode = One Way or Cyclic not available Object Configuration -> Object Hold Off not available Object Preview -> Live Preview not available Release Notes

30 1xB10, 1xB14, 1xK78 + NO K62 -> no correct Routing of BBin Release Notes

31 1.6 Version Released: February 2017 New Functionality Support of SZU100A, IQ UPCONVERTER Fixed Issues Sporadic error message with AM Known Issues NRP-Z57 not working properly with SZU100A FREQ:RCL EXCL not working properly with SZU100A Custom Digital Modulation: control lists are not supported B13XT/AWGN noise only : baseband has to be switched on Known Issues K78 (Radar Echo Generation) Object Configuration -> Type = Moving -> Simulation Mode = One Way or Cyclic not available Object Configuration -> Object Hold Off not available Object Preview -> Live Preview not available For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases For 24 Moving Objects with different velocity after some minutes DSP-Error 0x8004 is observed For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again. Release Notes

32 1.7 Version Released: November 2016 New Options SMW-K115 : Cellular IoT SMW-K116: DVB-S2 New Options (first time available with B9) SMW-K42: 3GPP FDD SMW-K46: CDMA2000 SMW-K47: 1xEV-DO Rev A SMW-K50: TD-SCDMA SMW-K51: TD-SCDMA enhanced SMW-K52: DVB-H/DVB-T SMW-K54: n SMW-K60: Bluetooth/DER SMW-K68: Tetra 2 SMW-K83: 3GPP FDD HSPA/HSPA+ (ex 43/45/59) SMW-K86: AC SMW-K87: 1xEV-DO Rev B New Functionality New SCPI command to get last calibration date (:CALibration:DATA:FACTory:DATE?) I/Q Stream mapper now working with B9/B13XT Extended display of new software components and data sheet version (menu Software/Options has been renamed to Version/Options) Possibility to export built-in help files to /var/user Fixed Issues Extended Sequencing (K501): baseband frequency and gain offset do not work , List mode with I/Q high quality mode: GSM signal not generated correctly Level mode Uninterrupted Level Settings" does not switch electronic attenuator when RF output is off Instruments with B120 and B220: no RF output on path B List mode with ALC OFF S&H: error message shows up Settings characteristic 'Constant phase' renamed to 'Continuous phase' ad : burst power depending on idle time SMW-K73: several bug fixes and minor improvements , AWGN/B13XT: noise only mode not working if baseband is switched off Marker output TMC1/2/3 sometimes ahead to I/Q analog out 1 by 25 µs (sporadic) Unwanted signals output during instrument is in armed trigger state Failed to access ARB waveform memory (B13XT/B9) Several bug fixes and minor improvements with B9 and custom dig. Modulation, ARB and MCCW Digital impairments (I/Q skew) not working at IQ/ Analog Out with B ,215292, ,252691, , Release Notes

33 All editors: save as.. not working Known Issues Custom Digital Modulation: control lists are not supported B13XT/AWGN noise only : baseband has to be switched on Known Issues K78 (Radar Echo Generation) Object Configuration -> Type = Moving -> Simulation Mode = One Way or Cyclic not available Object Configuration -> Object Hold Off not available Object Preview -> Live Preview not available For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases For 24 Moving Objects with different velocity after some minutes DSP-Error 0x8004 is observed For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again. EUTRA/LTE Compatibility Information All supported features are in line with 3GPP release 13, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/- K105) New Feature Filter optimization types Best Evm and Best Evm No Upsampling are now also supported on SMW with B9 options New Feature First version to support the options K115 and K415 (Cellular IoT) New Feature Support for user defined filters in LTE New Feature Support for the EPDCCH channel New Feature Uplink K81 logfile generation for NB-IoT and emtc uplink channels New Feature Uplink Support for emtc channels PUSCH, PUCCH and PRACH New Feature Uplink Support for NB-IoT channels NPUSCH and NPRACH in inband, guard band and standalone modes Changed Behavior The filter optimization type Best Evm is now the default value also on SMW with B9 options Changed Behavior In cases of carrier aggregation with mixed duplexing or mixed TDD parameters in different carriers, power reference mode "Frame RMS Power" is used Fixed Issue Discretely presetting the parameter "cut off frequency factor" (in filter optimization mode Best ACP) could cause the value to be wrong. Release Notes

34 Fixed Issue Fix for uplink or downlink carrier aggregation cases with disabled PCell Fixed Issue In case of downlink or uplink carrier aggregation, a configured carrier delay did not work properly in case of coupled system configurations , , Fixed Issue Minor fixes in the user interface Fixed Issue Bugfix for PDSCH with UE specific reference symbols and discontinuous RB allocation Fixed Issue Correction for DCIs in cases of carrier aggregation with mixed duplexing or mixed TDD parameters in different carriers Fixed Issue Further fix for Auto Sequence mode "Target Code Rate" Fixed Issue In special carrier aggregation cases, the parameter dependencies from the associated uplink carrier configuration were not properly resolved after recall Fixed Issue In special cases, configured DCIs were missing after recall Fixed Issue In special cases, the PDCCH region was not adapted correctly in special subframes Fixed Issue Level bugfix for exported waveform files in case of carrier aggregation with separate system configuration and mixed duplexing or mixed TDD parameters in different carriers , , , , Fixed Issue Minor fixes in the user interface Fixed Issue Recalling setup files from older firmware versions into recent ones did not reliably work in case of TDD with PDSCH scheduling modes AutoDci or Autosequence Fixed Issue Sometimes the time plan was drawn incorrectly in uplink carrier aggregation cases with mixed duplexing or mixed TDD parameters in different carriers Fixed Issue Uplink Corrected K81 logging point numbering for the logging points precoding and DFT precoding Fixed Issue Uplink Levelling fix for Reference Mode "UE Burst RMS Power" in case of very large values of the ARB sequence length Fixed Issue Uplink Minor fixes in the user interface Fixed Issue Uplink Sometimes the time plan was drawn incorrectly in uplink carrier aggregation cases with mixed duplexing or mixed TDD parameters in different carriers Open Issue Improved On/Off ratio for TDD is not supported in combination with "Best ACP" or "Auto" filter optimization types Open Issue The "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode Open Issue Uplink Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation Open Issue Test Case Wizard Open Issue Test Case Wizard Home BS test cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard. Test Case 8.2.1A is not yet available in the test case wizard. Release Notes

35 1.8 Version Released: September 2016 New Options SMW-K820 : Customized Dynamic Fading New Functionality Support of new NRPxxyN LAN power sensors Detection of NRPxxy USB sensors accelerated Radar Echo Generator (SMW-K78): delay calibration and several other improvements License Infos / Open Source Acknowledment displayed in Software Options Dialog B9: maximum symbol rate extended to 600 Msym/s B13XT: support of AWGN Fixed Issues Baseband level measurement failed B9: several improvements high quality mode Signal delay to external trigger too high (now: < 20 ns) LF outputs: source noise not working correctly ARB: multi-segment waveforms with more than 500 segments do not work DPD: gap between internal and external power measurement Tetra (SMW-K68): wrong TX frequency calculation Tetra (SMW-K68): RAB/SCH-Q-RA/channel 28 cannot be activated B9: external trigger using connector User3 not working B9/Custom Dig Mod: distorted signal with very short data lists WLAN n / MIMO: signal may be incorrect Instruments with/b106/b220/b20: B22 is used with path B (must be path A) B9: level error with AM modulation B9: sporadic I/Q swaps on I/Q outputs when IQ modulator settings are changed Fading: SCME Uma presets with deactivated polarization leads to wrong correlation MIMO 2x2x2 (SMW used as baseband fader): signal of entity 2 may be wrong B9/B13XT: wrong rear panel shown after Find connectors G (K114): fixed bug in f-ofdm filtering mode resulting in an improved EVM and OOB characteristics Known Issues Wideband instruments (2xB9) have to be switched off/on after software update Custom Digital Modulation: control lists are not supported B13XT/AWGN noise only : baseband has to be switched on Known Issues K78 (Radar Echo Generation) Object Configuration -> Type = Moving -> Simulation Mode = One Way or Cyclic not available Object Configuration -> Object Hold Off not available Object Preview -> Live Preview not available Release Notes

36 For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases For 24 Moving Objects with different velocity after some minutes DSP-Error 0x8004 is observed For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again. EUTRA/LTE Compatibility Information New Feature All supported features are in line with 3GPP release 12, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/- K103/-K104/-K105). Codebook indices now can be configured individually in PDSCH allocations even for "User" PDSCH allocations New feature DCI format 2D and transmission mode New Feature New Feature / New Feature carrier aggregation with mixed duplexing, according to release 12. carrier aggregation with mixed TDD uplink/downlink configuration or special subframe configuration, according to release 11. Independent PHICH configuration for individual downlink carriers New Feature Release 12 feature "Enhanced 4Tx Codebook" New Feature RLC counter for PDSCH scheduling mode "Auto Sequence" New Feature The TDD structure is displayed in case of carrier aggregation Changed Behavior Changed Behavior Changed Behavior Filter optimization type "Best Evm no upsampling" has been deactivated for B9 SMWs. Improved the UI behavior when setting cell indices in downlink or uplink carrier aggregation tables. The configuration of user specific antenna port tables (for user specific RS) can now be done independently for cases with different numbers of layers / Fixed Issue Not all subframes could be displayed in the time plan Fixed Issue On very high data rates for PDSCH or PUSCH the firmware could crash Fixed Issue Performance improvement for "Generate waveform file" Fixed Issue Fixed Issue Fixed Issue Sometimes the signal filtering stopped working after carrier aggregation was used in separate system configuration mode. The timing of triggered signals was sometimes wrong in coupled system configurations. Additional fixes for the DCI coding of the DAI in case of MBSFN Fixed Issue DCI bug fixes for DL carrier without associated uplink carrier / Fixed issue Fixed behavior for Auto Sequence mode "Target Code Rate" Fixed Issue Fixed GUI behavior of DCI configuration for SPS. Release Notes

37 Fixed Issue Fixed Issue / Fixed Issue Fixed Issue / Fixed Issue / Fixed Issue Fixed issue Fixed possible force close if carrier aggregation settings are reconfigured while the main LTE state is on. Fixed SCPI commands for configuring the cell specific downlink antenna port table. For PBCH SFN restart period "3GPP", the PBCH power sometimes was incorrect for coupled system configurations. For PDSCH scheduling mode "Auto Sequence", the "Autofill" feature did not work reliably for SCells. Improved GUI behavior of UL DCI RBA/MCS in case of PDSCH scheduling mode "Auto Sequence". In case of PDSCH scheduling mode "Auto Sequence" together with carrier aggregation, the DCI templates were possibly constructed for the wrong cell index. In cases with two codebook indices, the indices were not correctly transferred from user settings to allocation settings Fixed Issue Recalling DCI CCE indices did sometimes not work Fixed Issue Fixed Issue Fixed Issue Save/Recall of the "Associated UL Carrier" configuration did not work. The range of DCI CCE index could be wrong in case five carriers were active. The range of the random codebook index 2 sometimes was wrong Fixed Issue The range of the user codebook index was sometimes wrong / / Fixed Issue Uplink Fixed Issue Uplink Fixed Issue Uplink Configuring the PUSCH resource allocation in a specific order could cause error messages or even a firmware crash. GUI improvements for uplink carrier aggregation with mixed duplexing or mixed TDD settings. Loading TDD setup files from older firmware versions in newer firmware versions could cause corrupt settings Fixed Issue Uplink LTE realtime feedback debug reports are available again Fixed Issue Uplink PRACH subframe states have not been saved to setup files Fixed Issue Uplink Fixed Issue Uplink Open Issue Open Issue Saving uplink frame configuration settings to setup files did not work reliably. The PUSCH redundancy version was not configurable for UE2 to UE4. Improved On/Off ratio for TDD is not supported in combination with "Best ACP" or "Auto" filter optimization types. The "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode Open Issue The EPDCCH channel is not yet supported in this version Open Issue Uplink Open Issue Open Issue Test Case Wizard Test Case Wizard Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation. Home BS test cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard. Test Case Wizard: Test Case 8.2.1A is not yet available in the test case wizard. Release Notes

38 1.9 Version Released: May 2016 New Options SMW-K550 : Stream Extender SMW-K73 : OTA-MIMO Fading Enhancements SMW-K78 : Radar Echo Generation SMW-K141 : IEEE ad SMW-K501 : Extended Sequencing (SMW-B10 required) Wideband Options (available from ) SMW-B13XT: Wideband Baseband Main Module SMW-B9: Wideband Baseband Generator SMW-K515: ARB Memory extension to 2 GSamples SMW-K526: Baseband extension to 2 GHz bandwidth SMW-K17: Wideband differential I/Q outputs New Functionality Support of new power sensors NRP40S, NRP50S, NRP6A, NRP18A, NRP18T, NRP33T, NRP40T, NRP50T, NRP67T and NRP110T Remote emulation for Keysight PSG series added 5G Air Interface Candidates : Added wrap-around for filtering in f-ofdm Manual master trigger using connector User 6 Custom Digital Modulation : easy method to generate CW by selecting CW in Baseband from standard menu 40 GHz instruments : improved handling of overload protection 3GPP-FDD / Uplink - Closed loop power control for HSUPA/FRC - Compressed Mode for HSUPA, by means of User Scheduling - DCH and HSUPA/FRC channel coding for compressed Mode, by means of User Scheduling - Closed loop power control for compressed mode, by means of User Scheduling Fixed Issues External baseband clock sometimes not working correctly Fading simulation: correlation of SISO-paths not always correct Instruments equipped with 2xB10 and 2xB14 sometimes crash after activating baseband B Analog modulations not always deactivated in Advanced Modes like 4x1x Custom Digital Modulation: APCO modulation G: Problems if UFMC Preamble size is Instruments with two B14: baseband does not trigger Connected external RFs (SGS/SGT): sporadic connection problems Trigger Source Internal A for baseband B: trigger delay not correct Release Notes

39 Known Issues Custom Digital Modulation: shift between control and data list Known Issues K78 (Radar Echo Generation) Object Configuration -> Type = Moving -> Simulation Mode = One Way or Cyclic not available Object Configuration -> Object Hold Off not available Object Preview -> Live Preview not available For 2xK78 and addition of both streams in Stream Mapper: automatic level calculation not working correctly in all cases Automatic System Latency Calibration not available For 24 Moving Objects with different velocity after some minutes DSP-Error 0x8004 is observed For Moving Object with Start-Range > End-Range, Level might be clipped. Workaround: turn object off and on again. For Moving Object with Start-Range > End-Range and "Use Radar Range Ambiguity" = ON, delay calculation is not correct EUTRA/LTE Compatibility information New Feature All supported features are in line with 3GPP release 12, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/- K105). Additional leveling information is displayed when exporting waveform files in case of coupled system configuration New Feature Configuration of the MIB spare bits is possible now New Feature Uplink Changed Behavior The TDD structure is displayed in case of carrier aggregation. For TM9 users, the "codebook" feature now fills the PDSCH antenna port table according to the number of coupled outputs and the actually used number of beam forming layers instead of always 8 outputs and 8 layers. Also, the configurable range of the codebook index was increased in order to support all possible cases Changed Behavior Removed the unused channel type RSVD Changed Behavior Uplink Changed Behavior Uplink In case of uplink carrier aggregation with mixed duplexing or mixed TDD UL/DL configurations now the power reference mode "Frame RMS Power" is used. In case of uplink carrier aggregation, UE mode PRACH is not allowed , , Fixed Issue Minor fixes in the user interface Fixed Issue Fixed Issue Fixed Issue The time plan was displayed incorrectly in case of cyclic prefix type "user defined". Test Case Wizard Corrected the noise power in for test case Test Case Wizard In case of test case 8.3.8, the parameter n_pucch of antenna port 201 was wrong. Release Notes

40 Fixed Issue Fixed Issue Corrected the maximum length of the MBSFN notification pattern. Independently modifying several physical PDSCH allocations of the same 'User' could cause misaligned settings or even a force close , , , , Fixed Issue Minor fixes in the user interface Fixed Issue Fixed Issue Fixed Issue Fixed Issue Uplink The DCI coding of the Assignment Index (DAI) was incorrect in case of MBSFN. When using E-TMs on more than one component carrier, the PDCCH settings on the SCells were different from the PCell. The available range of transmission modes was sometimes not matching the global MIMO configuration. Depending on the actual instrument configuration, uplink carrier aggregation sometimes did not support mixed duplexing even if option K113 was installed , , , , , , , , , , , , , , Fixed Issue Uplink Minor fixes in the user interface Fixed Issue Uplink Fixed Issue Uplink Open issue Open issue Open issue Test Case Wizard Test Case Wizard Open issue Open issue Uplink Open issue Uplink Not all subframes were configurable in case of uplink carrier aggregation with mixed duplexing or mixed TDD UL/DL configuration. PUCCH allocation conflicts as well as some read only PUCCH information were not displayed correctly in the user interface. Improved On/Off ratio for TDD is not supported in combination with "Best ACP" or "Auto" filter optimization types. Home BS test cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard. Test Case 8.2.1A is not yet available in the test case wizard. The "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode. Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation. Real-time feedback: Debugging feature "Generate Debug Reports" is disabled in this version. Release Notes

41 1.10 Version Released: December 2015 New Options SMW-B140N : Frequency option 100 khz to 40 GHz, I/Q modulation bandwidth and minimum pulse width limited SMW-K308 : Direction Finding SMW-K113 : LTE Release 12 SMW-K114 : 5G Air Interface Candidates New Functionality SMW-K75 : Support of MIMO-Modes 1x4x8, 1x8x4 and 2x4x4 B131/B140: Accelerated switching time between frequency ranges below/above 19.5GHz Improved handling of reference mode noise with coupled AWGN Fixed Issues ARB/multi-segment waveforms: ID and name cannot be read by SCPI Suppression of reference oscillator unlocked messages during boot-up ---- Improvements for trigger coupling baseband A -> baseband B SYST:FPR;*OPC? returns too soon Measured external clock sometimes wrong WLAN 11b: odd of PSDU data length causes CRC error in DUT SOURce1:SWE:FREQ:POINts? sometimes returns a value too small Tetra: clipping not working Waveform transfers by SCPI (MMEM.DATA) sometimes leads to crashes EUTRA/LTE Compatibility information New feature All supported features are in line with 3GPP release 12, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/- K105). First version to support the LTE options K113 and K413 (EUTRA/LTE Release 12) New feature 256QAM modulation for PDSCH and PMCH New feature New 256QAM test models (E-TMs) of 3GPP TS New Feature Support for DCI format 1C with eimta-rnti New feature Uplink Aperiodic SRS (SRS trigger type 1) New feature Uplink Changed behavior Support of release 12 mixed duplexing configurations in uplink carrier aggregation. The carrier aggregation table baseband column is now hidden in case of separate system configurations. Release Notes

42 Fixed issue Fixed issue Directly after upgrading the firmware version the filter optimization mode "Auto" was not set. Filter optimization mode "Auto" was not set after recalling files from previous firmware versions Fixed issue Bugfix for conflicting PDSCH and CSI-RS allocations Fixed issue In case of carrier aggregation, the PDSCH scheduling mode "Auto DCI" could cause wrong allocations for specific cell index values Fixed issue Minor fix in the user interface Fixed issue Minor fix in the user interface Fixed issue Minor fix in the user interface Fixed issue Fixed issue Uplink Fixed issue Uplink Using PDSCH scheduling mode "Auto Sequence" together with carrier aggregation could make the firmware crash. Configuring the enhanced channel settings was not possible for some subframe configurations. For complex system configurations, configuring the uplink antenna port table could lead to error messages Fixed issue Uplink Minor fix in the user interface Fixed issue Uplink Minor fix in the user interface Fixed issue Uplink Minor fix in the user interface Fixed issue Uplink Minor fix in the user interface Fixed issue Uplink Minor fix in the user interface Fixed issue Uplink Recalling setup files from old firmware versions could cause error messages due to an invalid uplink antenna port mapping Fixed issue Uplink SRS in special subframes was not displayed in timeplan Fixed issue Uplink SRS was sometimes displayed incorrectly in timeplan Fixed issue Fixed issue Test Case Wizard Test Case Wizard Open issue Open issue Open issue Uplink Open issue Uplink Open issue Uplink Open issue Open issue Open issue Test Case Wizard Test Case Wizard Test Case Wizard For test case 8.3.8, the wrong number of PUCCH antenna ports was set. The test case wizard did not reset the unused stream mapper settings. Improved On/Off ratio for TDD is not supported in combination with "Best ACP" or "Auto" filter optimization types. The "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode. PUCCH allocation conflicts as well as some read only PUCCH information are not displayed correctly in the user interface. Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation. Real-time feedback: Debugging feature "Generate Debug Reports" is disabled in this version. Home BS test cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard. In case of test case 8.3.8, the parameter n_pucch of antenna port 201 is set to 0. Test Case 8.2.1A is not yet available in the test case wizard. Release Notes

43 1.11 Version Released: September 2015 New Options SMW-K75 : Higher Order MIMO (eg. 2x2x4, 2x4x2) SMW-B93 : Solid State Drive (SSD) SMW-B83/B84: Rear Connectors 20 Ghz Path A/B New Functionality Support of MW4OPU WinIQSIM2 waveforms can now be used with internal firmware option too. Example: waveform contains K255 option. Instrument is equipped with K55 but not with K255. Waveform can be played anyway. NFC: maximum number of command blocks extended to 300 DPD and ET: several improvements (eg. new SCPI commands to read operating points) Extended customer support info (Setup/Maintenance/Create R&S Support Information) VSWR display in RF level dialog Fixed Issues List mode: import/export to/from CSV does not work MIMO 4x1x1 : block diagram shows redundant control NFC: wrong range of power offset NFC: The total sequence duration was displayed wrongly GPP/FDD: Correction of interval ranges in the HS-DPCCH PCI/CQI table GPP/FDD: In case several basebands calculated simultaneously, the calculation could have failed Baseband Input: auto level set and sample rate measurement not working correctly 15456, ET: characteristic displayed sometimes wrong after switching to power scale Baseband gain does not work, when signals are added before fader Custom DigMod / external data : upper limit of symbol rate sometimes wrong Pattern editors: no valid range displayed in tool tip Fader: sporadic DSP error after retriggering Custom DigMod / GSM : some strange effects with power ramping 13569, Release Notes

44 EUTRA/LTE Compatibilit y information Compatibilit y information New feature New feature Uplink All supported features are in line with 3GPP release 11, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/-K105). Configuration of associated uplink carriers in case of downlink carrier aggregation (15307, 15771). Support of release 11 mixed TDD UL/DL configurations in uplink carrier aggregation (15292). Changed behavior Harmonized the SCPI commands for different antenna port tables (15352). Changed behavior Changed behavior In mode "SISO+BF" it is now possible to switch off antenna port 0 on individual baseband outputs (14466). More flexibility in mapping antenna ports to baseband outputs (14677, 15700). Changed behavior Uplink A configured SFN offset is visualized in the time plan (14732). Fixed issue Minor GUI improvements (15213, 15431, 14992, 15383, 15200, 15323). Fixed issue Fixed issue Fixed issue Fixed issue Fixed issue Fixed issue Fixed issue Fixed issue Test Case Wizard: Stream mapper was not reliably configured in case of nondefault routing (15688). Test Case Wizard: Test cases and were not configurable by means of SCPI (15493). The possible range of delta f in the downlink and uplink carrier aggregation tables was sometimes wrong (15657). Correction for random codebook feature in case of single layer users with transmission mode 8 (15486). CSI-RS were sent in wrong subframes in case the periodicity was configured to be more than one frame (15235). Overlapping resource allocations were not possible for MU-MIMO with beamforming users (15433). Sometimes the PHICH ACK/NACK pattern length was incorrect after preset (15655). Zeros were appended to DCI format 1A even in case of no associated uplink carrier (15236). Fixed issue Uplink Fixed leveling in case of uplink carrier aggregation (15415, 15407). Fixed issue Open issue Open issue Uplink The power offset of the uplink antenna port mapping was not taken into account in single carrier cases (15841). Home BS test cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard (13287). Improved On/Off ratio for TDD is not supported in combination with "Best ACP" or "Auto" filter optimization types (14432). Open issue Test Case 8.2.1A is not yet available in the test case wizard (13641). Open issue Open issue Open issue Uplink Uplink The "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode (13681). Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation (14433). Real-time feedback: Debugging feature "Generate Debug Reports" is disabled in this version (13804). Release Notes

45 1.12 Version Released: June 2015 New Options SMW-B83 : Rear Panel Connectors for RF path A (20/31.8/40 GHz) and I/Q SMW-B84 : Rear Panel Connectors for RF path B (20 GHz) New Functionality New instrument home page with - LXI features - Web Control (VNC based remote operation) - SCPI Remote trace (command logging) DPD (K541): - characteristics can be displayed linear (voltage based) - accelerated setting times - normalized shaping and inversion added MAC address is displayed at the bottom of network settings Individual output states for I/Q Digital streams More flexible remote control of external devices (SGT/SGS) Custom Digital Modulation: support of external data Custom Digital Modulation: support of symbol rates down to 50 Hz Fixed Issues Baseband Powers not working correctly for baseband E-H 15126, Sporadic error Synchronization error on reference pll please check ext. reference connection with SSYN ( xx) WLAN: signal does not start with single trigger and duration > SL Using 8x1x1 with only two B14 options : calculation of maximum ARB clock rate wrong SCPI: Some fading command do not work properly w/o option K ARB / multi segment waveforms: external trigger not working correctly In single mode C2K: downlink s F-FCH and F-SCH s more params button can t be open Several minor problems when SMW is controlling SGS/SGT ET/DPD (K540/K541) : wrong output power in some cases SCPI: Armed Retrig Mode not working with MIMO 4xN Setups ET (K540): several minor bugs and enhancements 14720, 14719, 14709,14568, 14391,14314, 13885, SMW/SGT Setup: AWGN level sometimes not correct Fading: With Mutli-Entity-Modes 5x1x1 8x1x1, Doppler shift too small by a factor of Tetra: Power ramping of QAM modulated signals not correct ARB/coupled sources: changing clock frequency of baseband B has no effect BB powers is not working correctly with >=4 streams or multi gated , 13440, External clock not working correctly SCPI: SOUR:BB:W3GP:MST1:ENH:DPDC:INT2 ON not working Release Notes

46 SCPI/List node : lists with less items than rows are filled up with wrong value Slow IQ (K551): signal at FADING output sometimes corrupted Tetra: error message shows up when activating T4 signals longer than BBMM1/2 output signals is delayed if I/Q OUT 1/2 is deactivated (approx. 70 µs) Tetra: Crest factor is wrong SMW/SGT: several minor bugs and enhancements 14224, 14223, 14166, 14157, 13900, GSM: stream C and D are delayed by approx. 190 µs List mode: Only working for B212 and B220 in live mode Fading: not working correctly in 2x2x2 mode when external I/Q data is used Some digitals standards do not work in 3x1x1 or 4x1x1 mode with only two faders (B14) Analog I/Q outputs deliver wrong voltage in mode differential/fixed EUTRA/LTE Compatibilit y Information This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/K105). New Feature New marker type "SFN restart period". New Feature Test case wizard now supports two-antenna-port PUCCH test cases and of 3GPP TS New Feature Uplink More flexible settings for uplink carrier aggregation (User settings, delay, power offset). Changed Behavior Changed Behavior Changed Behavior Changed Behavior Changed Behavior Changed the default PDSCH user specific antenna port mapping for advanced system configurations to a be more meaningful. Some filter improvements for special cases with carrier aggregation or high FFT size. antenna port table now shows cell number instead of cell index. time plan cell selection is now done by means of the cell number instead of the cell index. Uplink Increased the maximum possible number of PUSCH CQI bits to Fixed Issue "Generate Waveform" did not apply correct filtering anymore. Fixed Issue Accessing the file manager was not possible from within the K81 logging settings. Fixed Issue Carrier aggregation frequency offset did not work in case of only one activated carrier. Fixed Issue Fixes for carrier aggregation with different channel bandwidths on different carriers. Fixed Issue Minor fixes in the user interface. Fixed Issue Test case wizard: Bugfix for wanted signal level in test case 7.4 (only medium range BS class). Fixed Issue Test case wizard: Filter settings could be wrong after applying the same test case twice. Fixed Issue Test Case Wizard: Further bug fixes for TC 7.6 in case the outputs are swapped. (Useful for different RF frequency ranges). Release Notes

47 EUTRA/LTE (continued) Fixed Issue Test case wizard: Some settings were not visible for test case 7.4. Fixed Issue The maximum possible value for the ARB sequence length was wrong for basebands C and D. Fixed Issue "RS power per RE relative to level display" was sometimes 0 db. Fixed Issue "RS power per RE relative to level display" was sometimes wrong for carrier aggregation cases. Fixed Issue Allocation conflict was shown when two beamforming users shared the same frequency resources. Fixed Issue Auto sequence and MBSFN is not possible to activate simultaneously anymore. Fixed Issue Bugfix for "auto sequence". Fixed Issue Bugfix for DCI format 3 bit coding. Fixed Issue Delay setting for downlink carrier aggregation did not work for coupled system configurations. Fixed Issue MBSFN: Read-only allocation numbering was inconsistent. Fixed Issue Fixed possible force close when changing the number of layers of a PDSCH. Fixed Issue Uplink Fixed possible force close when SRS SFN offset is different from 0. Fixed Issue Uplink Minor fixes for uplink carrier aggregation. Fixed Issue Uplink PRACH was generated on all cells if uplink carrier aggregation was on and a UE was configured for PRACH. Open Issue Home BS Test Cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard. Open Issue Improved On/Off ratio for TDD is not supported in combination with ACPoptimized filter. Open Issue Test Case 8.2.1A is not yet available in the test case wizard. Open Issue "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode. Open issue Uplink Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation. Open issue Uplink Real-time feedback: Debugging feature "Generate Debug Reports" is disabled in this version. Known Issues This firmware release does not support R&S EXBOX-B85 (please use firmware version instead) External clock: measured and displayed value sometimes not correct (display problem only, output signal is correct) Digital I/Q In: Auto Level Set not working Selftest (protection level 1) : module tests not yet supported Release Notes

48 1.13 Version Released: March 2015 To use the same naming scheme as other R&S products, the default host name has been changed from rssmw200a<serial number> (for example rssmw200a123456) to SMW200A-<serial number> (SMW200A ). This new naming scheme is not used automatically by updating the firmware. Additionally a factory preset has to be performed. New Functionality Support of new processor board IPC11/2 Support of list mode (fast switching of frequency and/or level) Table editors like UCOR are now more user-friendly Tutorials: new modes for infinite loops and other improvements Fading K72: New presets and other improvements for SCME/WINNER SCPI: better error message when trying to write a read-only parameter Fading: ac also available for SISO modes SCPI: Alternative way to create waveforms by :MMEM:DATA:UNPR Fixed Issues 2x2x4 Mode: Mapping of fader outputs wrong (internal graphics only) ARB multi-segment: changes in trigger delay changes the active segment GSM: trigger delay does not work x1x2 Mode: some streams do not contain valid signals User Key/SCPI sequence: sporadic crashes with long sequences ARB multi-segment: Generation of waveforms bigger than 256 Ms shows error GUI: some elements do not show Show SCPI in context menu GSM/waveform : EVM too bad AWGN/CW interferer: signal shows spurs with negative ratio Remote: BB:ARB:TRIG:RMOD? takes more than 50 ms ARB multi-segment: SMW becomes very slow after long operation Release Notes

49 EUTRA/LTE Compatibilit y Information Compatibilit y Information All supported features are in line with 3GPP Release 11, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/K105). New Feature Uplink Uplink Carrier Aggregation (13329, 14575). Changed Behavior Test Case Wizard: Bug fix for TC 7.6 in case the outputs are swapped (13226). Fixed Issue Test Case Wizard: Bug fix for TC 7.6 in case the outputs are swapped (13226). Fixed Issue Fixed the leveling of coupled TDD carrier aggregation scenarios with different bandwidths on different carriers (11442). Fixed Issue For cases with more than two transmission layers and UE specific reference symbols, the leveling of the reference signals against the PDSCH was wrong. Fixed Issue Uplink The coding of PUSCH RI bits was wrong in case more than 11 RI bits were configured. Open Issue Test Cases for uplink transmission on more than one antenna port ( A, 8.3.7, 8.3.8) are not yet available in the test case wizard (13641, 14233). Open Issue Home BS Test Cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard (13287). Open Issue Improved On/Off ratio for TDD is not supported in combination with ACPoptimized filter (14432). Open Issue "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode (13681). Open Issue Uplink Real-time feedback is not yet supported for uplink MIMO and uplink carrier aggregation (14433). Open Issue Uplink Real-time feedback: Debugging feature "Generate Debug Reports" is disabled in this version (13804). Known Issues Selftest (protection level 1) : module tests not yet supported External clock not functional B212/B220: List mode only working in Live mode 1.14 Version Released: February 2015 New Functionality Support of new options SMW-B131 / SMW-B140 : Frequency options up to 40 GHz (Path A) SMW-K76 Multiple Entities SMW-K89 / SMW-K289 NFC A/B/F SMW-K112 / SMW-K412 LTE Release 11 and Enhanced Features SMW-K542 Baseband Power Sweep SMW-K551 Slow IQ Release Notes

50 SMW-K300 Pulse Sequencing (supporting old K6 waveforms) SMW-K301 Enhanced Pulse Sequencing SMW-K350 DFS Signal Generation SMW-K256 XM Radio SMW-K407 Beidou 1 Satellite Support of new power sensors NRP8S, NRP18S and NRP33S Undo/Redo (by context menu, full history by Setup/Settings) Several built-in tutorials (Setup/Help/Tutorials) -> see new application card how to generate tutorials by your own Remote: value out range error message now contains add. Information Value of digital attenuation now taken into account for level display User Interface / security: new modes Touchscreen off and VNC only Accelerated switching time SOURce1:IQ:STATe ON/OFF System Configuration Selection of signal output configuration (incl. Digital Only Multiplexed ) Support of up to 8 entities (requires new prefix Entity for SCPI remote control New baseband source config Coupled Sources per Entity mode Baseband Fading can be retriggered by baseband Improved graphics: marker values with units, persistence, reference traces Active graphics are recovered after restarting (and part of save/recall) Fading: VAMOS support added Several improvements with digital I/Q IN and OUT interfaces Several improvements handling multi segment waveforms Fading(K72: customized fading profile added Improved stability with external RF sources like SGT100A (including delay compensation) SGS100A with SGU100A is supported as external RF Digital I/Q IN : possibility for I/Q swap added Several improvements with digital predistortion and envelope tracking AWGN: C/N extended to +45 db Fading: new fading profile n-SISO RF/Level/ALC: support added for driver amplifiers ARB: Level mode introduced Bluetooth: new parameter Slot timing Fading (SCME/WINNER): calculation of polarization correlation matrix B90: frequency sweep now allowed with active LO coupling Fixed Issues Remote Emulation of SMU : some missing commands FSIM: Hardcopy includes BUSY-LED Changes is fading, AWGN, phase and frequency offset retrigger the baseband Several external connectors can be used for same internal signal Release Notes

51 Baseband Powers shows dbm with some signal routings Context menu: Several non-working display of SCPI commands and more Graphics do not show signal, if baseband is not routed to output Sporadic startup problem (progress bar never disappears) GPP-FDD: loading DL test models does not reset OCNS state RF: data valid signal sometimes not correct when changing frequency or level ARB: short drop out after starting in single trigger mode WLAN: wrong output level (sporadic) Instruments w/o option K18 show hardware missing at startup GSM: waveform files cannot be generated Digmod: BPSK with split phase filter generates bad signal Baseband power shows wrong value with MIMO 4x BB:ARB:WAV:CATalog? sometimes returns truncated file names Setting times too long when power sensor is connected DPD/ET : digital attenuation not taken into account Digmod: user mapping and user coding not working under all circumstances 12876,13110 Fading: Summation ratio snot working Input trigger polarity not changed during *RST Tetra: illegal combinations of modes and channel types Digmod: APCO filter uses wrong roll off SGS as external RF: up to 1dB output level error User preset (if a file named UserPreset.savrcltxt is placed at /var/user) not working I/Q signals are swapped after changing MIMO configuration ARB: last marker slope delayed B90: MIMO coupling did not work correctly below 200 MHz Tetra: RAB could not generate second half slot,, some minor bugs in code interleaver Release Notes

52 3GPP New Feature Uplink Now simultaneous external HARQ feedback and external uplink power control is possible (12913). New Feature Uplink Now UE2-4 can be power controlled according to the UE1 power control steps (12914). New Feature Uplink Now PRACH/PCPCH repetition periods other than the ARB sequence length are possible (12996). Fixed Issue Minor corrections in the user interface (12157,14105,13222,14044,13378,11873,14036,11884,11128,14031,11872,13350). Fixed Issue The filter type "Gauss (Pure)" was not remote configurable (13367). Fixed Issue Uplink Bug fix for power control in case the up range is not a multiple of the step size. Fixed Issue Uplink In case of HS-DPCCH slot format 1, transmissions happened in the wrong slots of the very first radio frame (13541). Fixed Issue Uplink User Scheduling showed false warnings about misplaced DPDCH, E-DCH and power control commands if these were not present in the User Scheduling file (12869). Fixed Issue Uplink The PRACH/PCPCH structure in the user interface showed wrong level offsets for power reference modes different from "RMS power". Fixed Issue Uplink When selecting an uplink test model, a warning "value out of range" was shown. The signal was correct anyhow (12395). EUTRA/LTE Compatibilit y Information Compatibilit y Information All supported features are in line with 3GPP Release 11, i.e. the following official 3GPP specifications are implemented: TS v , TS v , TS v This version is compatible with Rohde & Schwarz EUTRA/LTE Analysis Software Version 3.4 SP1 (FSx-K100/-K101/-K102/-K103/-K104/K105). New Feature First version to support the LTE options K112 and K412 (LTE Release 11 and enhanced features) (12544). New Feature New release 11 special subframe configurations 9 (for normal cyclic prefix) and 7 (for extended cyclic prefix). New Feature Test Case Wizard: Included release 12 in the release selection and extended the test cases to 8 Rx antennas where applicable. New Feature New PDSCH scheduling mode "Auto Sequence" (13681). New Feature Uplink Extended PUCCH format 3 according to release 11. New Feature Uplink Longer PUSCH RI and CQI patterns are possible now (13309). New Feature Uplink OCC for PUSCH, possibility to switch off OCC in case of single antenna port transmission. New Feature Uplink PUCCH and SRS transmission via more than one antenna port. New Feature Uplink Spatial multiplexing for PUSCH (Uplink MIMO, Uplink Transmission Mode 2). New Feature Uplink Extended the K81 logging functionality for uplink direction. Changed Behavior Changed Behavior Changed Behavior Changed Behavior Changed Behavior Test case wizard: RF outputs can be swapped now for test case (13226). Added LTE support for SMW system configuration modes "Coupled per entity". Improved the K81 logging functionality in case of SMW "Coupled" system configuration modes. Increased the maximum number of entries of the PDCCH DCI table. In TM8/TM9 beamforming cases with "Codebook" mapping, the default power allocation in the antenna port table was changed by 3 db in order to match typical use cases (13454). Release Notes

53 Changed Behavior Changed Behavior Changed Behavior Changed Behavior Changed Behavior Changed Behavior Changed Behavior Removed the reserved "RSVD" channel type (13492). Individual users can be switched off now (13851, 13798) Uplink Uplink Uplink The maximum possible number of downlink subframe table allocations was reduced for high bandwidth cases. Unused downlink allocations are not shown in the subframe configuration table anymore. Changed the PRACH skipping of root Zadoof-Chu sequences according to the 3GPP clarification R (13467). Non-standard values for n(2)_dmrs are not supported anymore. UE release selection "Release 10" was renamed to "LTE-Advanced" (13666). Fixed Issue Marker rise/fall offsets did not work for marker type "Frame Active Marker". Fixed Issue Test case wizard: In , the wrong fading scenario was set ("HST" instead of "HST DL+UL") (13530). Fixed Issue Minor fixes in the user interface (13166, 14212, 13548). Fixed Issue Test case wizard: For some SMW hardware / software configurations, not all AWGN blocks were switched off for test cases that did not need AWGN (13586). Fixed Issue Internal armed triggering failed in baseband C and D in case of SMW system configuration mode "separate" (13855). Fixed Issue DCI formats 2, 2A: An active "Transport Block to Code Word Swap Flag" caused an undefined behavior in cases of only one transport block. Fixed Issue Fixed a possible firmware crash in case of entering the enhanced PBCH settings dialog if the option K85 was not available (13155). Fixed Issue In PDSCH mode "Auto DCI", the transport block size was derived wrongly from the MCS in some multi-layer cases. Fixed Issue Bug fix for cases when CSI-RS collide with CRS in the same symbol. Fixed Issue Various fixes for PDSCH scheduling mode "Auto-DCI" and for the DCI table (13697). Fixed Issue The PBCH power was reset after configuring DCIs in PDSCH scheduling mode "Auto-DCI" (13478). Fixed Issue In SMW system configuration modes "separate", wrong precoding codebooks were used in case the simulated antenna was not "Antenna 1" (13567). Fixed Issue DCI parameter "SRS Request" was missing for some DCI formats (13233). Fixed Issue On recalling a setup file with a P_A value different from default, the PDSCH power was not corrected accordingly (13209). Fixed Issue The number of PHICH groups was not determined correctly in Auto DCI mode. Fixed Issue The PBCH data source was not used correctly in case of Scheduling Mode "Auto-DCI". Fixed Issue The PDCCH could not be switched off properly in individual subframes in case of Scheduling Mode "Auto-DCI" (13227). Fixed Issue The PDSCH power was not determined correctly in Scheduling Mode "Auto-DCI" in case of 4 Tx Diversity. Fixed Issue The value range of the "SRS Request" field in the DCI configuration was wrong. Fixed Issue Bug fix for CSI-RS with extended cyclic prefix. Fixed Issue Bug fix for the selection of the simulated antenna in "SISO+BF" case. Fixed Issue PDSCH Scheduling Mode "Auto DCI": Bug fix for semi persistent scheduling in case the PDCCH is switched off. Fixed Issue Uplink Bug fix for PRACH restricted set. Release Notes

54 Fixed Issue Uplink Correction of FRC A of TS Fixed Issue Uplink Correction of the channel coding of PUSCH HARQ ACK information in case more the 11 bits are coded. Fixed Issue Uplink PUSCH mode UCI-only: The number of coded RI bits was determined incorrectly. Fixed Issue Uplink RI coding on PUSCH was wrong for cases with more than 2 RI bits. Fixed Issue Uplink A ULSCH transport block size of 0 was configurable. Open Issue Test Cases for uplink transmission on more than one antenna port ( A, 8.3.7, 8.3.8) are not yet available in the test case wizard (13641, 14233). Open Issue Home BS Test Cases ( , 6.2.7, 6.2.8) are not yet available in the test case wizard (13287). Open Issue Improved On/Off ratio for TDD is not supported in combination with ACPoptimized filter (14432). Open Issue "Autofill" feature for PDSCH scheduling mode "Auto Sequence" is not yet available for TDD duplexing mode (13681). Open issue Uplink Real-time feedback is not yet supported for uplink MIMO (14433). Open issue Uplink Real-time feedback: Debugging feature "Generate Debug Reports" is disabled in this version (13804). Known Issues Selftest (protection level 1) : module tests not yet supported External clock not functional 1.15 Version Released: April 2014 New Functionality Support of new options SMW-B120 / SMW-B220 : Frequency options up to 20 GHz (Path A / Path B) Support of new modules SSYN: , SYNEX: , , , WLAN: idle time resolution improved to 0.1 µs Fixed Issues SCPI-Recording : Some missing commands (pulse modulation) xEVDO : some stability issues 12744, GPP-Waveforms generated by WinIQSM2 not supported Several digital standards: small memory leaks after signal calculation 12630, 12541, 12540, Custom Digital Modulation: using CLIST for User1 not always working Fading/MIMO : correlation matrix not always recalculated after changing MIMO-Mode Tetra : burst power too low Release Notes

55 FM/AM : activating both modulations simultaneously leads to error message Bluetooth: data order wrong and whitening sequence shifted Known Issues Selftest (protection level 1) : module tests not yet supported Baseband External clock not functional Signal is retriggered after changing fading or baseband routing Fading: if not in bypass mode, signal starts only 50 ms delayed Custom digital modulation: User mapping/filer may cause errors Some MIMO-Configurations not yet fully supported Digital Inputs / Outputs on FADER boards not supported 1.16 Version Released: January 2014 New Functionality Support of new options SMW-K541 AM/AM, AM/PM Predistortion SMW-B81 Rear connectors path A SMW-B82 Rear connectors path B New commands to control external RF sources from remote (like :SCONfiguration:EXTernal:IQOutput1:REMote SOOUR1:FREQ 2.1 GHZ ) Improved operation: selection of digital standard in baseband block starts with last used entry Baseband/common trigger source: support of individual trigger delays ARB: waveform info now shows additional information I/Q graphics is now able to scale in µs Minor reduction of settling times WLAN: added beacon frames for 11b and HT capability Fixed Issues LF sweep in path B not working x1x2 MIMO supported with only two fading options B Baseband signal interrupted when RF state is switched User key dialog does not support all necessary characters from keyboard Signal trigger not working when basebands are added and baseband state A is off LF generator 2 of modulation A does not work with pulse, triangle or trapezoid shapes Release Notes

56 User Interface (mouse/vnc operation after touch gestures) : context menus sometimes not working properly SMW becomes very slow with VNC access when invalid DNS server address is used GPP: Signals with realtime components stopped working whenever the "Generate Waveform" functionality was used WLAN: several smaller issues fixed Known Issues Selftest (protection level 1) : module tests not yet supported Baseband External clock not functional Signal is retriggered after changing fading or baseband routing Fading: if not in bypass mode, signal starts only 50 ms delayed Some MIMO-Configurations not yet fully supported Digital Inputs / Outputs on FADER boards not supported 1.17 Version Released: October 2013 Fixed Issues ARB/multi segment: markers and play list not functional AWGN : noise level not always calculated correctly (LF level without effect) User correction with more than entries not working GPP : some minor fixes UL-DTX (GUI only) Digital modulation : CW Mode signal not available at Local Connectors Additionally several minor issues, only relevant for manufacturing, have been fixed. Known Issues Selftest (protection level 1) : module tests not yet supported User Interface (mouse/vnc operation after touch gestures) : context menus sometimes not working properly Baseband External clock not functional Signal is retriggered after changing fading or baseband routing Fading: if not in bypass mode, signal starts only 50 ms delayed ARB: Waveform info does not show marker info and needed options Tetra (multi-carrier modes) sometimes invalid signal output Some MIMO-Configurations not yet fully supported Release Notes

57 Digital Inputs / Outputs on FADER boards not supported 1.18 Version Released: September 2013 New Functionality Support of new options SMW-K244 GPS (using R&S WinIQSIM2 SMW-K266 Galileo 1 satellite (using R&S WinIQSIM2 SMW-K294 Glonass 1 satellite (using R&S WinIQSIM2 SMW-K540 Envelope tracking SMW-K739 Differential analog I/Q inputs for RF path A Access to network shares (file servers) supported (Save/Recall -> File Manager) New security features to disable Write nonvolatile memory, display and keyboard/touch screen Improved error message after incomplete SCPI commands Sweep running display in the block diagram (head panel) Improved scrolling with touch screen (gravity effect and within tables) User interface for RF level dialog extended Touch panel test integrated Baseband Full support for MIMO Mode 1x3x3, 1x8x1, 1x8x2 Support for MIMO Mode 1x1x8, 1x2x8 with subset Analog I/Q outputs: resolution of offset improved to 100 µv Custom digital modulation: support of QAM4096 Accelerated calculation of long waveforms (e.g. 3GPP-FDD) Extended bias range for digital I/Q out WLAN now supports coupled baseband sources Graphics support triggered mode (by marker 1) Fading Correlation matrix (AoA/AoD) : number of clusters extended to 6 Display of user settings file name New profile for ac-mimo (TGac channel model) Modified Functionality Common trigger parameters forced in case of added basebands (baseband signals can be added before or after fading or within stream mapper) NRP-Z power viewer: aperture time added and sensors always start with average power even if wideband sensor Exporting SCPI lists from Save/Recall dialog now uses extension txt Remote control: default directory for MMEM commands changed to /var/user Release Notes

58 IEEE WLAN : sub-standard ( a/g, b/g, p/j, n, ac) selectable Fixed Issues Correct handling of I/Q modulator state when (de-)activating baseband blocks System Configuration: 2 x 2 x 2 : AWGN configuration in block 2 not correct User correction / Fill with sensor not working with all start/stop frequencies Baseband phase offset setting causes gap in the RF signal Custom digital modulation : QAM symbol rate limited to 25 MHz (instead of 50 MHz) Baseband signal of path B delayed compared to path A when routing A->A+B Tabbed dialogs : change of tabs not correctly working with roll key navigation Info/History : messages of path B are shown with path=a in first column GPP test case wizard : trigger setting not applied MIMO 2x2: Sync output to external trigger not working for baseband B User interface / list boxes : unsuited values are not grayed GSM sometimes shows problems with DSP after start up Digital impairments : skew settings not working correctly No signal valid signal available at user connector Pulse modulation graph always low Digital I/Q in : Auto setting sometimes causes crashes External trigger not working with custom digital modulation Hard key Next Window not working perfectly Digital modulation : trigger mode Single not working Custom digital modulation : list management moved to list select dialog File manager : folders sometimes do not open up after single touch K522 : Wrong bandwidth limitation to 100 MHz w/o B14 (fading simulator) Instruments with single baseband and double RF : sporadic errors with AWGN in path B ARB : trigger delay not working correctly Very large waveforms not displayed with MMEM:CAT? Marker signal sticks to high for some µs after trigger event Fading (HST) : initial propagation delay leads to shift in marker timing Routing of baseband signals remains unchanged after switching system configuration Fading : insertion loss display not working Baseband signal is retriggered after changing frequency or phase offset Baseband Powers : measurement results are not reliable with AWGN and C/N < 0 db Configuration 1BB +2HF: LevAtt in RF B does not work Digital modulation: QAM1024 with pattern and gauss filter: crest factor wrong GPP Fixed Issues: Clipping for Generate Waveform File did not work. Fixed. H-Set Mode Constant-NACK : The Transport Block Size Index was signaled incorrectly in the HS-SCCH. Fixed. Additionally several minor issues like missing help links, SCPI command display or optical glitches could be fixed. Known Issues Selftest (protection level 1) : module tests not yet supported Release Notes

59 Baseband External clock not functional Signal is retriggered after changing fading or baseband routing Fading: if not in bypass mode, signal starts only 50 ms delayed ARB: Waveform info does not show marker info and needed options ARB/multi segment: markers and play list not functional Tetra (multi-carrier modes) sometimes invalid signal output Some MIMO-Configurations not yet fully supported Digital Inputs / Outputs on FADER boards not supported 1.19 Version Released: April 2013 Known Issues SMU emulation not yet 100% covered Signal Valid line (by default mapped to user connector 5) always is LOW Progress bar sometimes not visible not working correctly Context menu (touching longer than 1 s) : not all features available for all parameters where applicable Pulse modulation : pulse graph does not show trace Selftest (protection level 1) : module tests not yet supported USB remote control : transfer of large files sometimes fails Baseband External trigger not working with custom digital modulation External clock not functional Coupled baseband sources not fully supported for all standards where applicable Single trigger not functional Signal is retriggered after changing AWGN or similar settings Baseband Input Settings : Auto Setting not working ARB : Waveform info does not show marker info and needed options ARB/multi segment : next segment trigger sometimes not working Tetra (multi-carrier modes) sometimes invalid signal output Graphics : hardware trigger not working 3GPP : Test case wizard sometimes does not set the correct trigger mode Baseband Powers : measurement results are not reliable when using AWGN with C/N < 0 db Release Notes

60 GSM : instrument may generate dsp communication errors if GSM was activated during last shutdown. In this case, reboot instrument and press for the first two seconds after power on. Some MIMO-Configurations not yet fully supported 1x1x8, 1x2x8, 1x8x1,1x8x2 Fading : AoA/AoD not fully supported Digital Inputs / Outputs on FADER boards not supported Release Notes

61 Modifications to the Documentation 2 Modifications to the Documentation The current documentation is up-to-date. Release Notes

62 Firmware Update 3 Firmware Update 3.1 Downgrade ly it is not recommended to use an earlier version than the latest version available. In some cases the older versions do not support the hardware used in your instrument. Before installing this firmware, check if this could happen: Start System Config / Setup / Instrument Assembly / Software/Options In the tab Firmware, you find the If the version to be installed is greater or equal than the Min.Version, the hardware will be supported after downgrading. (However, this cannot be guaranteed for all software options) If the version to be installed is lesser than the Min.Version, not all of the modules will be supported. You instrument will not work after downgrading! Downgrading may fail using standard rsu-files (eg. due to changes in the instrument configuration file). In this case, press PRESET-Button during power-on or install ISO image available from service department. 3.2 Update Information The update procedure requires that the instrument is operational. There is no need to uninstall the current firmware. Instrument settings are preserved during the update, including user data and network settings. Release Notes

LTE-A Base Station Performance Tests According to TS Rel. 12 Application Note

LTE-A Base Station Performance Tests According to TS Rel. 12 Application Note LTE-A Base Station Performance Tests According to TS 36.141 Rel. 12 Application Note Products: ı R&S SMW200A ı R&S SGS100A ı R&S SGT100A 3GPP TS36.141 defines conformance tests for E- UTRA base stations

More information

Pre-5G-NR Signal Generation and Analysis Application Note

Pre-5G-NR Signal Generation and Analysis Application Note Pre-5G-NR Signal Generation and Analysis Application Note Products: R&S SMW200A R&S VSE R&S SMW-K114 R&S VSE-K96 R&S FSW R&S FSVA R&S FPS This application note shows how to use Rohde & Schwarz signal generators

More information

Digital Standards for Signal Generators Specifications

Digital Standards for Signal Generators Specifications Digital Standards for Signal Generators Specifications R&S SMW200A vector signal generator, R&S SMBV100A vector signal generator Data Sheet Version 14.00 CONTENTS Introduction... 4 Notations and abbreviations...

More information

EUTRA/LTE Measurement Application Specifications

EUTRA/LTE Measurement Application Specifications EUTRA/LTE Measurement Application Specifications R&S VSE-K10x R&S FSx-K10x R&S FS-K10xPC Test & Measurement Data Sheet 02.00 CONTENTS Definitions... 3 Specifications... 4 General remarks... 4 Overview...

More information

LTE-A Base Station Receiver Tests According to TS Rel. 13

LTE-A Base Station Receiver Tests According to TS Rel. 13 LTE-A Base Station Receiver Tests According to TS36.141 Rel. 13 Application Note Products: R&S SMW200A R&S SMF100A R&S FSW R&S SMB100A R&S FSV R&S SGS100A R&S FSVA R&S SGT100A R&S FPS 3GPP TS36.141 defines

More information

Higher Order MIMO Testing with the R&S SMW200A Vector Signal Generator

Higher Order MIMO Testing with the R&S SMW200A Vector Signal Generator Application Note C. Tröster-Schmid 01.2016-1GP97_1E Higher Order MIMO Testing with the R&S SMW200A Vector Signal Generator Application Note Products: R&S SMW200A R&S SGS100A R&S SGT100A Due to its outstanding

More information

Digital Standards for Signal Generators Specifications

Digital Standards for Signal Generators Specifications Digital Standards for Signal Generators Specifications R&S SMW200A vector signal generator, R&S SMBV100A vector signal generator Data Sheet Version 13.01 CONTENTS Introduction... 4 Notations and abbreviations...

More information

LTE Bitstream Verification. Application Note. Products: R&S SMW200A R&S SMU200A R&S SMx-K55 R&S SMx-K81 R&S FS-K10xPC R&S FSW R&S FSQ R&S FSV R&S FPS

LTE Bitstream Verification. Application Note. Products: R&S SMW200A R&S SMU200A R&S SMx-K55 R&S SMx-K81 R&S FS-K10xPC R&S FSW R&S FSQ R&S FSV R&S FPS Application Note Bernhard Schulz, Fabian Liebl 01.2015-1MA161_1e LTE Bitstream Verification Application Note Products: R&S SMW200A R&S SMU200A R&S SMx-K55 R&S SMx-K81 R&S FS-K10xPC R&S FSW R&S FSQ R&S

More information

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies Agilent Technologies N5106A PXB MIMO Receiver Tester Messages Agilent Technologies Notices Agilent Technologies, Inc. 2008 2009 No part of this manual may be reproduced in any form or by any means (including

More information

EUTRA/LTE Downlink Specifications

EUTRA/LTE Downlink Specifications Test & Measurement Data Sheet 03.00 EUTRA/LTE Downlink Specifications R&S FS-K100PC/-K102PC/-K104PC R&S FSV-K100/-K102/-K104 R&S FSQ-K100/-K102/-K104 R&S FSW-K100/-K102/-K104 CONTENTS Definitions... 3

More information

Digital Standards for Signal Generators Specifications

Digital Standards for Signal Generators Specifications Digital Standards for Signal Generators Specifications R&S SMW200A, R&S SMU200A, R&S SMATE200A, R&S SMJ100A, R&S SMBV100A, R&S AMU200A, R&S AFQ100A, R&S AFQ100B Test & Measurement Data Sheet 08.00 CONTENTS

More information

R&S FSW-K144 5G NR Measurement Application Specifications

R&S FSW-K144 5G NR Measurement Application Specifications R&S FSW-K144 5G NR Measurement Application Specifications Data Sheet Version 01.00 CONTENTS Definitions... 3 Specifications... 4 Overview... 4 Assignment of option numbers to link modes... 4 Supported

More information

LTE RF Measurements with the R&S CMW500 according to 3GPP TS Application Note. Products: R&S CMW500

LTE RF Measurements with the R&S CMW500 according to 3GPP TS Application Note. Products: R&S CMW500 Jenny Chen May 2014 1CM94_5e LTE RF Measurements with the R&S CMW500 according to 3GPP TS 36.521-1 Application Note Products: R&S CMW500 The 3GPP TS 36.521-1 Radio transmission and reception LTE User Equipment

More information

LTE Downlink MIMO Verification

LTE Downlink MIMO Verification LTE Downlink MIMO Verification with R&S SMU200A and R&S FSW Application Note Products: R&S SMU200A R&S SMATE200A R&S AMU200A R&S FSW R&S FSQ R&S FSG R&S FSV Multiple Input Multiple Output (MIMO) is an

More information

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications Test & Measurement Data Sheet 01.00 CONTENTS Definitions... 3 Specifications... 4 Frequency... 4 Level... 4 Signal acquisition...

More information

R&S FPS-K18 Amplifier Measurements Specifications

R&S FPS-K18 Amplifier Measurements Specifications R&S FPS-K18 Amplifier Measurements Specifications Data Sheet Version 02.00 Specifications The specifications of the R&S FPS-K18 amplifier measurements are based on the data sheet of the R&S FPS signal

More information

Generating WLAN IEEE ax Signals Application Note

Generating WLAN IEEE ax Signals Application Note Generating WLAN IEEE 802.11ax Signals Application Note Products: R&S SMW200A R&S SMBV100A R&S SGT100A R&S WinIQSIM2 TM Rohde & Schwarz signal generators can generate standard-compliant WLAN IEEE 802.11ax

More information

Multi-Channel Signal Generation Applications with R&S SMW200A Overview Application Note

Multi-Channel Signal Generation Applications with R&S SMW200A Overview Application Note Multi-Channel Signal Generation Applications with R&S SMW200A Overview Application Note Products: R&S SMW200A R&S SGT100A R&S SGS100A R&S SGU100A The R&S SMW200A vector signal generator has the outstanding

More information

Digital Standards for Signal Generators Specifications

Digital Standards for Signal Generators Specifications Digital Standards for Signal Generators Specifications R&S SMU200A, R&S SMATE200A, R&S SMJ100A, R&S SMBV100A, R&S AMU200A, R&S AFQ100A, R&S AFQ100B Test & Measurement Data Sheet 07.00 CONTENTS Introduction...

More information

1xEV-DO Test Solutions

1xEV-DO Test Solutions Products: R&S SMU200A Vector Signal Generator, R&S FSP, R&S FSU, R&S FSQ Spectrum Analyzers, R&S CMU200 Radio Communication Tester xev-do Test Solutions Application Note MA2 This application note provides

More information

LTE-A Base Station Transmitter Tests According to TS Rel. 13. Application Note. Products: R&S SMW200A R&S FSW R&S FSV R&S SMBV100A R&S FSVA

LTE-A Base Station Transmitter Tests According to TS Rel. 13. Application Note. Products: R&S SMW200A R&S FSW R&S FSV R&S SMBV100A R&S FSVA LTE-A Base Station Transmitter Tests According to TS 36.141 Rel. 13 Application Note Products: R&S FSW R&S SMW200A R&S FSV R&S SMBV100A R&S FSVA R&S FPS R&S VSE 3GPP TS36.141 defines conformance tests

More information

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications R&S FSQ-K91/K91n/K91ac WLAN 802.11a/b/g/j/n/ac Application Firmware Specifications Test & Measurement Data Sheet 03.00 CONTENTS OFDM analysis (IEEE 802.11a, IEEE 802.11g OFDM, IEEE 802.11j, )... 3 Frequency...3

More information

WCDMA Base Station Performance Tests according to TS25.141

WCDMA Base Station Performance Tests according to TS25.141 Application Note Schulz 5.2015 1MA78_0e WCDMA Base Station Performance Tests according to TS25.141 Application Note Products: R&S SMW200A R&S SMU200A R&S AMU200A R&S SMATE200A 3GPP TS25.141 defines conformance

More information

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications FSV_K76_dat-sw_en_5214-1572-22_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications 07.08.2013 18:42:49 CONTENTS Specifications... 3 Frequency... 3

More information

EUTRA/LTE and LTE-Advanced Signal Analysis Transmitter measurements on LTE signals

EUTRA/LTE and LTE-Advanced Signal Analysis Transmitter measurements on LTE signals EUTRA/LTE and LTE-Advanced Signal Analysis Transmitter measurements on LTE signals R&S FS-K100PC/-K101PC/-K102PC/-K103PC/-K104PC/-K105PC Test & Measurement Product Brochure 03.00 EUTRA/LTE and LTE-Advanced

More information

WaveDevice Hardware Modules

WaveDevice Hardware Modules WaveDevice Hardware Modules Highlights Fully configurable 802.11 a/b/g/n/ac access points Multiple AP support. Up to 64 APs supported per Golden AP Port Support for Ixia simulated Wi-Fi Clients with WaveBlade

More information

LTE Beamforming Measurements. Application Note

LTE Beamforming Measurements. Application Note Application Note Bernhard Schulz April 03-MA87_e LTE Beamforming Measurements Application Note Products: R&S SMW00A R&S SMU00A R&S SMU-K55 R&S SMBV00A R&S SMJ00A R&S SMATE00A R&S EX-IQ-Box R&S OSP R&S

More information

GENERAL PURPOSE Signal generators. R&S SMBV100A vector signal generator allrounder and specialist at the same time

GENERAL PURPOSE Signal generators. R&S SMBV100A vector signal generator allrounder and specialist at the same time R&S SMBV100A vector signal generator allrounder and specialist at the same time 36 The attractively priced R&S SMBV100A offers performance that was previously available only in considerably more expensive

More information

This application note is a simple step-by-step guide that introduces a practical method to perform reliable small cell planning.

This application note is a simple step-by-step guide that introduces a practical method to perform reliable small cell planning. Application Note Samuel Tretter 1.2017 1MA297_0e Reliable small cell planning using LTE test transmitter Application Note Products: R&S SGT100A R&S TSME R&S ROMES4 Reliable small cell planning is essential

More information

Internet of Things. RF-Test. Eduardo Inzunza Speaker Title 18-Jun-2017

Internet of Things. RF-Test. Eduardo Inzunza Speaker Title 18-Jun-2017 Internet of Things RF-Test Eduardo Inzunza Speaker Title 18-Jun-2017 Topics IoT Introduction IoT Spectrum Analysis IoT Signal Analysis does not create an obligation for to deliver any of the features,

More information

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream SFD_bro_en_3607-3739-12_v0100.indd 1 Product Brochure 01.00 Test & Measurement Broadcast & Media year 24.05.2016

More information

LTE-A Base Station Transmitter Tests According to TS Rel. 12. Application Note. Products: R&S SMW200A R&S FSW R&S FSV R&S SMBV100A R&S FSVA

LTE-A Base Station Transmitter Tests According to TS Rel. 12. Application Note. Products: R&S SMW200A R&S FSW R&S FSV R&S SMBV100A R&S FSVA LTE-A Base Station Transmitter Tests According to TS 36.141 Rel. 12 Application Note Products: R&S FSW R&S SMW200A R&S FSV R&S SMBV100A R&S FSVA R&S FPS 3GPP TS36.141 defines conformance tests for E- UTRA

More information

XRAN-FH.WP.0-v01.00 White Paper

XRAN-FH.WP.0-v01.00 White Paper White Paper xran Fronthaul Working Group White Paper The present document shall be handled under appropriate xran IPR rules. 0 xran.org All Rights Reserved Revision History Date Revision Author Description

More information

Correlated Receiver Diversity Simulations with R&S SFU

Correlated Receiver Diversity Simulations with R&S SFU Application Note Marius Schipper 10.2012-7BM76_2E Correlated Receiver Diversity Simulations with R&S SFU Application Note Products: R&S SFU R&S SFE R&S SFE100 R&S SFC R&S SMU200A Receiver diversity improves

More information

W-CDMA Base Station Transmitter Tests According to TS Rel. 10

W-CDMA Base Station Transmitter Tests According to TS Rel. 10 W-CDMA Base Station Transmitter Tests According to TS25.141 Rel. 10 Application Note Products: R&S FSW R&S FSQ R&S FSV R&S SMW200A R&S SMU200A R&S SMJ100A R&S FPS 3GPP TS25.141 [1] defines conformance

More information

R&S VSE Vector Signal Explorer Base Software Specifications

R&S VSE Vector Signal Explorer Base Software Specifications R&S VSE Vector Signal Explorer Base Software Specifications Data Sheet Version 11.00 CONTENTS Definitions... 3 Specifications... 4 Minimum system requirements for the R&S VSE... 4 Running on a PC... 4

More information

GALILEO Timing Receiver

GALILEO Timing Receiver GALILEO Timing Receiver The Space Technology GALILEO Timing Receiver is a triple carrier single channel high tracking performances Navigation receiver, specialized for Time and Frequency transfer application.

More information

Guidelines for MIMO Test Setups Part 2 Application Note

Guidelines for MIMO Test Setups Part 2 Application Note Guidelines for MIMO Test Setups Part 2 Application Note Products: R&S SMU200A R&S AMU200A R&S SMATE200A R&S SMBV100A R&S AMU-Z7 Multiple antenna systems, known as MIMO systems, form an essential part of

More information

R&S CMW500 Digital IQ with CADENCE Emulator Application Note

R&S CMW500 Digital IQ with CADENCE Emulator Application Note R&S CMW500 Digital IQ with CADENCE Emulator Application Note Products: R&S CMW500 R&S EX-IQ-BOX R&S FSQ R&S FSV R&S EXBOX-Z3 This application note explains how to bring a CADENCE system which is attached

More information

Versatile RF Fading Simulator With R&S FSQ/FSG/FSV and R&S SMU Application Note

Versatile RF Fading Simulator With R&S FSQ/FSG/FSV and R&S SMU Application Note Versatile RF Fading Simulator With R&S FSQ/FSG/FSV and R&S SMU Application Note Products: R&S SMU200A R&S SMU-B17 R&S SMU-B14 R&S FSQ R&S FSG R&S FSQ-B17 R&S FSV R&S FSV-B17 R&S FSV-B70 Fading in the baseband

More information

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz Broadcast Product Brochure 02.00 R&S ETH Handheld TV Analyzer At a glance The R&S ETH handheld TV analyzer was specially designed

More information

Tests on 3G-Base Stations to TS with FSIQ and SMIQ

Tests on 3G-Base Stations to TS with FSIQ and SMIQ Products: FSIQ, SMIQ Tests on 3G-Base Stations to TS 25.141 with FSIQ and SMIQ This application note describes how to measure the various WCDMA signals which are used for transmitter tests on FDD base

More information

R&S CONTEST ITS Test cases and applications

R&S CONTEST ITS Test cases and applications CONTEST_ITS_Test_Cases_dat-sw_en_3607-0352-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S CONTEST ITS Test cases and applications 31.05.2016 14:03:11 CONTENTS Definitions... 3 CONTEST basic

More information

Generating Signals for WLAN ac

Generating Signals for WLAN ac Application Note C. Tröster 07.2012-1GP94_0E Generating Signals for WLAN 802.11ac Application Note Products: R&S SMU200A R&S SMATE200A R&S SMBV100A R&S SMJ100A R&S SGS100A R&S AMU200A R&S AFQ100A R&S AFQ100B

More information

LabWindows/CVI, VXIpnp driver history for the R&S SGMA Vector RF Source

LabWindows/CVI, VXIpnp driver history for the R&S SGMA Vector RF Source Miloslav Macko January 31, 2017 LabWindows/CVI, VXIpnp driver history for the R&S SGMA Vector RF Source Products: R&S SGT100A Driver history for LabWindows/CVI and VXIplug&play Instrument Driver for C/C++,

More information

LabWindows/CVI, VXIpnp driver history for the R&S Spectrum Analyzers Driver Documentation

LabWindows/CVI, VXIpnp driver history for the R&S Spectrum Analyzers Driver Documentation Miloslav Macko May 18, 2016 LabWindows/CVI, VXIpnp driver history for the R&S Spectrum Analyzers Driver Documentation Products: R&S FSUP R&S FSH4/8 R&S FSMR R&S ZVH R&S ESL R&S FSC Driver history for LabWindows/CVI

More information

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications FSV-K73_dat-sw_en_5214-0976-22_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications 01.08.2013 17:36:27 CONTENTS Specifications... 3 Frequency...

More information

R&S VSE Vector Signal Explorer Base Software Specifications

R&S VSE Vector Signal Explorer Base Software Specifications Data Sheet Version 10.00 R&S VSE Vector Signal Explorer Base Software Specifications VSE_dat-sw_en_3607-1371-22_v1000_cover.indd 1 26.04.2018 10:05:34 CONTENTS Definitions... 3 Specifications... 4 Minimum

More information

PRACTICAL PERFORMANCE MEASUREMENTS OF LTE BROADCAST (EMBMS) FOR TV APPLICATIONS

PRACTICAL PERFORMANCE MEASUREMENTS OF LTE BROADCAST (EMBMS) FOR TV APPLICATIONS PRACTICAL PERFORMANCE MEASUREMENTS OF LTE BROADCAST (EMBMS) FOR TV APPLICATIONS David Vargas*, Jordi Joan Gimenez**, Tom Ellinor*, Andrew Murphy*, Benjamin Lembke** and Khishigbayar Dushchuluun** * British

More information

Converting MediaFLO Waveform Files to R&S SFU / SFE / SFE100 ARB Format Using IQWIZARD/WinIQSIM TM for R&S SFx-K35 ARB

Converting MediaFLO Waveform Files to R&S SFU / SFE / SFE100 ARB Format Using IQWIZARD/WinIQSIM TM for R&S SFx-K35 ARB Products: R&S SFU Broadcast Test System, R&S SFE Broadcast Tester, R&S SFE100 Test Transmitter Converting MediaFLO Waveform Files to R&S SFU / SFE / SFE100 ARB Format Using IQWIZARD/WinIQSIM TM for R&S

More information

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper Products: ı ı R&S FSW R&S FSW-K50 Spurious emission search with spectrum analyzers is one of the most demanding measurements in

More information

WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications

WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications R&S VSE-K91x R&S FSW-K91x R&S FPS-K91x Data Sheet Version 02.00 CONTENTS Definitions... 3 Specifications... 4 General remarks...

More information

R&S WMS32 Release Notes Software Version V

R&S WMS32 Release Notes Software Version V R&S WMS32 Release Notes Software Version V10.38.00 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

The Internet of Things in a Cellular World

The Internet of Things in a Cellular World The Internet of Things in a Cellular World Everything is connected!!! John Bews The Internet of Things in a Cellular World Agenda IoT Concept Cellular Networks and IoT LTE Refresher Reducing Cost and Complexity

More information

Tests on 3G-Base Stations to TS with R&S Spectrum Analyzers and SMIQ Vector Signal Generator

Tests on 3G-Base Stations to TS with R&S Spectrum Analyzers and SMIQ Vector Signal Generator Products: FSP, FSIQ, FSU, FSQ, SMIQ Tests on 3G-Base Stations to TS 25.141 with R&S Spectrum Analyzers and SMIQ Vector Signal Generator This application note describes how to measure the various WCDMA

More information

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations DTA-2115B Verification of Specifations APPLICATION NOTE January 2018 Table of Contents 1. Introduction... 3 General Description of the DTA-2115B... 3 Purpose of this Application Note... 3 2. Measurements...

More information

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 A fully integrated high-performance cross-correlation signal source analyzer from 5 MHz to 33+ GHz Key Features Complete broadband

More information

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25) Appendices 1 (25) Project designation R5 RIC Document title CONTENTS 2 (25) 1 References... 4 2 Dimensions... 5 3 Connectors... 6 3.1 Power input... 6 3.2 Video I... 6 3.3 Video Q... 6 3.4 Sync... 6 3.5

More information

RFEX V Release Notes

RFEX V Release Notes RFEX V6.1.50 Release Notes Products: R&S RFEX R&S RFEX-Fast This document gives an overview of the additional features and improvements that are implemented with version 6.1.50 Release Note

More information

NB-IoT Testing using Sage Instruments UCTT 8901

NB-IoT Testing using Sage Instruments UCTT 8901 SAGE INSTRUMENTS - Page 1 NB-IoT Testing using Sage Instruments UCTT 8901 1. The need for NB-IoT testing NB-IoT stands for Narrow-Band-Internet-of-Things. It is a 5G cellular based wireless wide area networking

More information

R&S BCDRIVE R&S ETC-K930 Broadcast Drive Test Manual

R&S BCDRIVE R&S ETC-K930 Broadcast Drive Test Manual R&S BCDRIVE R&S ETC-K930 Broadcast Drive Test Manual 2115.1347.02 05 Broadcast and Media Manual The Manual describes the following R&S Broadcast Drive Test software. 2115.1360.02 2115.1360.03 2116.5146.02

More information

ANSI/SCTE 40 Conformance Testing Using the R&S SFU, R&S SFE and R&S SFE100

ANSI/SCTE 40 Conformance Testing Using the R&S SFU, R&S SFE and R&S SFE100 R&S SFU broadcast test system ANSI/SCTE 40 Conformance Testing Using the R&S SFU, R&S SFE and R&S SFE100 Application Note The Society of Cable Telecommunications Engineers (SCTE) defined the ANSI/SCTE

More information

DOCSIS 3.1 Full channel loading Maximizing data throughput

DOCSIS 3.1 Full channel loading Maximizing data throughput DOCSIS 3.1 Full channel loading Maximizing data throughput Test and measurement High-end solutions Turn your signals into success. Introduction With over 80 years of experience in the field of RF test

More information

Arbitrary Waveform Generator

Arbitrary Waveform Generator 1 Arbitrary Waveform Generator Client: Agilent Technologies Client Representatives: Art Lizotte, John Michael O Brien Team: Matt Buland, Luke Dunekacke, Drew Koelling 2 Client Description: Agilent Technologies

More information

Be ahead in 5G. Turn visions into reality.

Be ahead in 5G. Turn visions into reality. e n e Be ahead in 5G. Turn visions into reality. 5G test solutions ) www.rohde-schwarz.com/5g 20937_003_5G Flyer_3606-8620-32_V0100_170310.indd 3 5G test challenge: Measuring new 5G systems 5G challenges

More information

DVB-T Bursted Noise Signal Generation

DVB-T Bursted Noise Signal Generation Products: R&S AFQ100A, R&S AFQ100B, R&S SMU, R&S FSL, R&S FSP, R&S FSQ, R&S FSU, R&S FSV, R&S AMU DVB-T Bursted Noise Signal Generation DVB-T Bursted Noise is a tool for generation of DVB-T compatible

More information

Arbitrary Waveform Sequencing with Rohde & Schwarz Vector Signal Generators. Application Note. Products: R&S SMBV100A R&S SMW200A R&S SMU200A

Arbitrary Waveform Sequencing with Rohde & Schwarz Vector Signal Generators. Application Note. Products: R&S SMBV100A R&S SMW200A R&S SMU200A Application Note C. Tröster 05.204-GP53_3E Arbitrary Waveform Sequencing with Rohde & Schwarz Vector Signal Generators Application Note Products: R&S SMBV00A R&S SMW200A R&S SMU200A R&S SMJ200A R&S AMU200A

More information

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0. SM06 Advanced Composite Video Interface: HD-SDI to acvi converter module User Manual Revision 0.4 1 st May 2017 Page 1 of 26 Revision History Date Revisions Version 17-07-2016 First Draft. 0.1 28-08-2016

More information

DVB-T2 modulator design supporting multiple PLP and auxiliary streams

DVB-T2 modulator design supporting multiple PLP and auxiliary streams > BMSB-2010 - mm2010-86 < 1 DVB-T2 modulator design supporting multiple PLP and auxiliary streams Correia S., Vélez M., Prieto G., Eizmendi I., Berjon-Eriz G., Fernández C., Ordiales J.L. Abstract This

More information

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006 Specifications Version 03.00 Bluetooth Tester CBT January 2006 Specifications CONTENTS UNIT SPECIFICATIONS...3 TIMEBASE TCXO...3 REFERENCE FREQUENCY INPUT...3 RF GENERATOR...3 RF ANALYZER...5 Power meter

More information

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ Products: AMIQ, SMIQ AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ The software AMIQ-K2 enables you to read, convert, and transfer various-format I/Q data files to AMIQ format. AMIQ-K2

More information

VR5 HD Spatial Channel Emulator

VR5 HD Spatial Channel Emulator spirent Wireless Channel Emulator The world s most advanced platform for creating realistic RF environments used to test highantenna-count wireless receivers in MIMO and beamforming technologies. Multiple

More information

Challenge Series Satellite High Speed DVB-S2 Modulator. 70/140 MHz IF Output L-Band Output. VideoACM. Flexibility, backward compatibility

Challenge Series Satellite High Speed DVB-S2 Modulator. 70/140 MHz IF Output L-Band Output. VideoACM. Flexibility, backward compatibility 70/140 MHz IF Output L-Band Output CCM, VCM, ACM Functionality The satellite high speed DVB-S2 modulator with 70 MHz/140 MHz IF or L-Band output provides high flexibility for the station design. The modulator

More information

Application Note DT-AN DTU-315 Verification of Specifications

Application Note DT-AN DTU-315 Verification of Specifications DTU-315 Verification of Specifications APPLICATION NOTE January 2018 Table of Contents 1. Introduction... 3 General Description of the DTU-315... 3 Purpose of this Application Note... 3 2. Measurements...

More information

NPR - Noise Power Ratio Signal Generation and Measurement

NPR - Noise Power Ratio Signal Generation and Measurement Products: AMIQ, SMIQ, SMR, FSEx, FSIQ, FSP, FSU NPR - Noise Power Ratio Signal Generation and Measurement Noise Power Ratio (NPR) is an add-on tool for WinIQSim to generate noise power ratio stimulus signals

More information

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications Data Sheet Version 02.00 CONTENTS Definitions... 3 Specifications... 4 Level... 5 Result display... 6 Trigger... 7 Ordering information...

More information

Tests On 3GPP WCDMA FDD Node Bs in Accordance with Standard TS

Tests On 3GPP WCDMA FDD Node Bs in Accordance with Standard TS Rohde & Schwarz products: WCDMA BS Test Set R&S FSMU-W, Signal Analyzer R&S FSQ, Vector Signal Generator R&S SMU200A and Microwave Signal Generator R&S SMR Tests On 3GPP WCDMA FDD Node Bs in Accordance

More information

Advanced Z7 OEM Universal Modulator

Advanced Z7 OEM Universal Modulator Product Features Direct RF output from 470 MHz to 860 MHz in 0.1 Hz steps (30 MHz to 1 GHz optional) Superior Shoulders and MER SFN and MFN Support Digital Adaptive Linear and Non-Linear Pre-correction

More information

Oscilloscopes for debugging automotive Ethernet networks

Oscilloscopes for debugging automotive Ethernet networks Application Brochure Version 01.00 Oscilloscopes for debugging automotive Ethernet networks Oscilloscopes_for_app-bro_en_3607-2484-92_v0100.indd 1 30.07.2018 12:10:02 Comprehensive analysis allows faster

More information

DM240XR Digital Video Broadcast Modulator With AutoEQ. Satellite Modems

DM240XR Digital Video Broadcast Modulator With AutoEQ. Satellite Modems DM240XR Digital Video Broadcast Modulator With AutoEQ Satellite Modems DVB Performance The DM240XR is DVB-S2 ready and can easily be upgraded in the field. The DM240XR provides a Typical Users comprehensive

More information

FullMAX Air Inetrface Parameters for Upper 700 MHz A Block v1.0

FullMAX Air Inetrface Parameters for Upper 700 MHz A Block v1.0 FullMAX Air Inetrface Parameters for Upper 700 MHz A Block v1.0 March 23, 2015 By Menashe Shahar, CTO, Full Spectrum Inc. This document describes the FullMAX Air Interface Parameters for operation in the

More information

Speeding up Spectrum Analyzer Measurements Application Note

Speeding up Spectrum Analyzer Measurements Application Note Speeding up Spectrum Analyzer Measurements Application Note Products: R&S FPS R&S FSW R&S FSV R&S SGT100A R&S SMW200A R&S SMBV100A Test time is a critical parameter when it comes to evaluating the cost

More information

Satellite Digital Broadcasting Systems

Satellite Digital Broadcasting Systems Technologies and Services of Digital Broadcasting (11) Satellite Digital Broadcasting Systems "Technologies and Services of Digital Broadcasting" (in Japanese, ISBN4-339-01162-2) is published by CORONA

More information

PXI UMTS DL Measurement Suite Data Sheet

PXI UMTS DL Measurement Suite Data Sheet PXI UMTS DL Measurement Suite Data Sheet The most important thing we build is trust Transceiver measurements of transmit power, modulation signal quality, spectral emissions and receive sensitivity using

More information

SPG700 Multiformat Reference Sync Generator Release Notes

SPG700 Multiformat Reference Sync Generator Release Notes xx ZZZ SPG700 Multiformat Reference Sync Generator Release Notes This document supports firmware version 3.0. www.tek.com *P077123104* 077-1231-04 Copyright Tektronix. All rights reserved. Licensed software

More information

4T2-Portable test set DVB terrestrial analyser system

4T2-Portable test set DVB terrestrial analyser system 1a test set DVB terrestrial analyser system COFDM analyser with MER performance >42 db in real-time 4k capable diversity receiver Spectrum, impulse response, group delay, and CCDF Automated multi-channel

More information

Datasheet SHF A

Datasheet SHF A SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23D 12277 Berlin Germany Phone +49 30 772051-0 Fax ++49 30 7531078 E-Mail: sales@shf.de Web: http://www.shf.de Datasheet SHF 19120 A 2.85 GSa/s

More information

SAGE Instruments UCTT 8901 Release Notes

SAGE Instruments UCTT 8901 Release Notes SAGE Instruments UCTT 8901 Release Notes Friday June 20, 2014, Sage Instruments is excited to announce a major new release for its wireless base station test tool, model 8901 UCTT. Release Summary This

More information

R&S SGT100A SGMA Vector RF Source Specifications

R&S SGT100A SGMA Vector RF Source Specifications R&S SGT100A SGMA Vector RF Source Specifications year Data Sheet Version 07.00 CONTENTS Definitions... 3 Key features... 4 Specifications... 5 RF performance... 5 Frequency... 5 Reference frequency...

More information

T80-K1 V2.22 Release Note

T80-K1 V2.22 Release Note T80-K1 V2.22 Release Note Products: R&S T80-K1 This document gives an overview of the additional features and improvements that are implemented with version 2.22 Release Note -

More information

BER MEASUREMENT IN THE NOISY CHANNEL

BER MEASUREMENT IN THE NOISY CHANNEL BER MEASUREMENT IN THE NOISY CHANNEL PREPARATION... 2 overview... 2 the basic system... 3 a more detailed description... 4 theoretical predictions... 5 EXPERIMENT... 6 the ERROR COUNTING UTILITIES module...

More information

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System 7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System A fully integrated high-performance cross-correlation signal source analyzer with platforms from 5MHz to 7GHz, 26GHz, and 40GHz Key

More information

Keysight E4729A SystemVue Consulting Services

Keysight E4729A SystemVue Consulting Services Keysight E4729A SystemVue Consulting Services DOCSIS 3.1 Baseband Verification Library SystemVue Algorithm Reference Library for Data-Over-Cable Service Interface Specifications (DOCSIS 3.1), Intended

More information

SIC receiver in a mobile MIMO-OFDM system with optimization for HARQ operation

SIC receiver in a mobile MIMO-OFDM system with optimization for HARQ operation SIC receiver in a mobile MIMO-OFDM system with optimization for HARQ operation Michael Ohm Alcatel-Lucent Bell Labs Lorenzstr. 1, 743 Stuttgart Michael.Ohm@alcatel-lucent.de Abstract We study the benfits

More information

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications Test & Measurement Data Sheet 01.01 CONTENTS R&S FSV-K8 Bluetooth /EDR measurement application... 3 Frequency...3 Measurement parameters...3

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

IEEE Broadband Wireless Access Working Group <http://ieee802.org/16>

IEEE Broadband Wireless Access Working Group <http://ieee802.org/16> 2004-01-13 IEEE C802.16-03/87r1 Project Title Date Submitted Source(s) Re: Abstract Purpose Notice Release Patent Policy and Procedures IEEE 802.16 Broadband Wireless Access Working Group

More information

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope Benefits of the R&S RTO Oscilloscope's Digital Trigger Application Note Products: R&S RTO Digital Oscilloscope The trigger is a key element of an oscilloscope. It captures specific signal events for detailed

More information