Passive ECC Penetration Duct

Size: px
Start display at page:

Download "Passive ECC Penetration Duct"

Transcription

1 GENES4/ANP2003, Sep , 2003, Kyoto, JAPAN Paper 1124 Passive ECC Penetration Duct Tae-Soon Kwon *, Chul-Hwa Song, and Won-Pil Baek Korea Atomic Energy Research Institute (KAERI), Thermal Hydraulic Research, Daejeon, Korea The ECC penetration duct of the direct vessel injection () system for the emergency core cooling (ECC) system has been studied to prevent steam-water interaction in the downcomer increasing the ECC bypass fraction during the late reflood phase of a large break loss-of-coolant accident (LBLOCA. The ECC penetration duct is installed from the nozzle at the upper downcomer to the lower downcomer. The performance of the extension duct was evaluated for both LBLOCA and line break of the APR1400 using the MARS code, which is a multi-dimensional best-estimate thermal hydraulic code being developed by KAERI. The shape of an advanced extension duct, which has a two exits at both the top and bottom of the duct, was considered to prevent an inlet-to-outlet switching of the extension duct during the line break. A vent hole is considered at the top of the ECC penetration duct to have the role of the break suction point at the upper downcomer. The break flow is initiated at both holes during the blowdown phase. But, the major break flow is switched from the bottom of the duct to the vent hole at the top caused by the difference in the static head. The results show the new ECC penetration duct having a vent hole at the top of the duct is very useful for both the reflood phase of LBLOCA and the line break. However, the fuel cladding temperature of the simply extended duct into the lower downcomer without vent top holes exceeds the limit value of 1200K. The collapsed water level both at the downcomer and core is also very low compared to those of the typical nozzle. The locations of nozzles both at the lower downcomer below the cold leg about 2 m and at the upper downcomer above the cold leg about 2 m are tested for both the LBLOCA and line break accident. The downcomer boiling and the late reheating occurred when the nozzle was installed at the lower downcomer. KEYWORDS : ECC penetration duct, ECC bypass, line break, LBLOCA I. Introduction APR1400 is a 3983 MWt evolutionary pressurized water reactor with two reactor coolant loops, each of which consists of one steam generator, one hot leg and two cold legs. For the safety injection system, APR1400 has four mechanically separated hydraulic trains with an emergency core cooling system (ECCS) 1) with direct vessel injection (). Each hydraulic train, is composed of a high pressure safety injection pump (SIP) and a safety injection tank (SIT), is connected to the nozzle (21.59 cm I.D.) located approximately 2.1 m above the centerline of the cold legs. Since emergency core cooling (ECC) water is directly injected into the upper part of the reactor vessel downcomer, the thermal-hydraulic phenomena during lossof-coolant accidents (LOCAs) could be quite different from those observed in the previous commercial PWRs adopting cold leg injection (CLI) type. 2) The bypass fraction and liquid entrainment of ECC water in the system is strongly dependent on the steam-water interaction in the downcomer. The ECC water injected into the downcomer is entrained due to high speed steam flow in the circumferential direction during the reflood phase of a LBLOCA. Thus, the in-vessel extension duct of the nozzle is a very useful method to prevent a * Corresponding author, Tel , Fax , tskwon@kaeri.re.kr steam-water interaction in the downcomer of a reactor vessel. However, if the extension duct has the shape of a simply extended pipe into the lower downcomer, the exit of the extension pipe plays the role of the inlet suction when the line break occurrs. Thus, the collapsed water level of the downcomer may become much lower than those of a typical system without the extension duct. Therefore, the simple pipe inserted into the lower downcomer as an extension duct may not be applicable for the line break only the LBLOCA. The performance of the extension duct should be applicable for both the LBLOCA and line break. If the vent hole is considered at the top of the simplified extension duct like a square chamber or pipe vertically installed in the downcomer, the extension duct has two exits both at the top and bottom. Then the top vent hole at the upper downcomer has a role of inlet suction during the line break. Thus, this design feature has the possibility of preventing the inlet-to-outlet switching of the extension duct while the ECC water may be discharged through both the bottom and top exits during the ECC injection phase of a LBLOCA. The elevation of the nozzle affects the collapsed water level in the downcomer. The peak cladding temperature and the ECC bypass fraction also depend on the injection location of the ECC water. Two types of injection locations, as shown in Fig.1 (a) and (b), are considered at about 2 m above the cold leg and at about 2 m below the cold leg. The collapsed water level of the lower system may be much lower than that of the high system. Because the break suction elevation of the lower system is much lower than the elevation of the cold leg during the line break accident. For LBLOCA,

2 the lower system is more effective in preventing the direct bypass of the ECC water, especially the liquid entrainment. However, the elevation of the nozzle as a break location is more important in the line break accident because the downcomer water level is strongly dependent on the elevation of the nozzle. To prevent the water level decreasing, the suction elevation of the break flow should be located at least near or above the elevation of the cold legs. In this paper, the performances of the extension duct and the effect of the nozzle elevation are evaluated focused on the peak cladding temperature, collapsed water level, and reheating for both a LBLOCA and line break accidents. High C.L. Hot Leg C.L. Hot Leg Low MARS, the new features of RELAP5/MOD3.2.2 γ-version are also implemented. The MARS code has the capability of analyzing the one-dimensional and/or three-dimensional thermal-hydraulic system and fuel responses of light water reactor transients. In the analysis presented in this paper, a one-dimensional module of the MARS employing the extended 3-D feature of the RELAP5/MOD3 is used. For the approximation of the multi-dimensional effects in the downcomer region, x-, y-, and z- coordinate directional flow geometry input are employed to apply the onedimensional momentum equation to each of the coordinate directions. This feature makes it possible to treat the momentum of each direction being convected by the velocity in the same direction. In this paper, the 8.5 inches line break and cold leg double ended guillotine breaks are taken into account for a reference accident to evaluate the performance of the elevation and the extension duct of the nozzle. The major parameters for comparison include the pressurizer pressure, break flow, cladding temperature, collapsed water level of the core and downcomer, core reheating, and the safety injection flow etc. C.L. (a) High (a) Simple type (b) Low Fig.1 nozzle elevation Hot Leg C.L. Hot Leg (b) Top and bottom hole type Fig. 2 Schematic of break suction II. Analysis Method To investigate the major thermal-hydraulic phenomena of the APR1400, under the anticipated accidental conditions, safety analysis has been performed using the best estimate computer code MARS. 4) The MARS code used for the analysis has been developed at KAERI by unifying and restructuring the RELAP5/MOD3.2.1 and COBRA-TF, the one-dimensional module and the threedimensional module respectively. In the course of the code's development, many improved features have been implemented to extend the code's modeling capability and to enhance user friendliness. In the current version of III. Component Model 1. nozzle and Extension Duct The break point is considered at the nozzle mounted at the upper downcomer in the APR1400 as shown in Fig.1(a). Thus the elevation of the break nozzles both the extended type and typical types are at the same elevation of the mounting point of the typical nozzle in the APR1400. The schematic is shown in Fig.2(a) and (b). However, as shown in Fig.2(a) and (b), the break suction point is at the lowest point of the extension duct in the downcomer not the mounting point of the nozzle because the extended duct into the lower downcomer has a role as a break path during the line break flow. The design features of the extended duct of the system in this test are shown in Fig.3(a), (b) and (c). As shown in Fig.3(c), the shape of the extension duct with a vent hole is somewhat different from the simple pipe particularly it's mounting at the downcomer as shown in Fig.3(b). The flow area in the vertical part of the duct is two times the flow area of the nozzle, while the top vent hole has a flow area same as the nozzle's. In the present analysis, the nozzle is located at 2 m above the cold legs. The duct is extended up to 2 m below the cold legs. The break flow of the line break is discharged through the ECC penetration duct from the lower downcomer region or the core inlet region. In the simplified duct extended into the lower downcomer as shown in Fig.4(a), the collapsed water level of the downcomer may be low because the break suction point is the extended duct exit during the line break. As shown in Fig.5(a) and (b), the extension duct has an internal type of a flow channel so that it may mitigate the phasic interaction between the steam and ECC water in the downcomer region during the late reflood phase of a LBLOCA.

3 Nozzle D/C C.L. Hot Leg C.L. Hot Leg (a) Typical Break (b) Simply extended Cold legs Steam Cross Flow (a) Simply extended duct (b) with top vent hole Fig.4 Schematic of line break s ECC Water Fig.3 (c) Top vent hole duct Type of extension duct However, as shown in Fig.4(b), if a vent hole is considered at the top of the ECC penetration duct to have a role of a break suction point at the upper downcomer, the break flow is initiated at both holes during the blowdown phase. The major break flow is switched from the bottom of the duct to the vent hole at the top caused by a difference in the static head of the extended duct. The region where the lines and cold legs are connected is modeled as 6 columns that are split azimuthally every 60 and each column is set to have 5 axial nodes. The lower and upper regions of the downcomer are modeled as a BRANCH component. The core flow goes through two channels: the average core channel and guide tubes. The bypass flow is simplified to have two channel flows: flows through the guide tube and key alignment simulator. For the low elevation of the nozzle, as shown in Fig.1(a), it is considered to be 2 m below the cold legs. (a) Typical (b) Extended duct Fig.5 Schematic of LBLOCA with 2. Reactor Vessel and downcomer As shown in Fig.6, the annular section of the APR1400 downcomer is modeled as 6 columns that are split azimuthally every 60. These columns are also divided by 10 axial nodes and the cross flows between these nodes are modeled to simulate the multi-dimensional flow behavior. The first, third, fourth, and sixth columns replicate the downcomer regions connected to the 4 cold leg nozzles and 4 nozzles, while the second and fifth columns represent the downcomer regions connected in the hot leg nozzle. A broken and three intact cold legs, and 4 lines are connected to the normal direction to the outer surface of the downcomer. The injected vessel flow splits into four channels; average core channel, hottest rod channel, core shroud bypass channel, and core guide tubes. The split vessel flows gather in the upper plenum of the reactor vessel and go out to each hot leg. Fig. 6 MARS 1-D nodalization for APR Steam Generator and Steam Lines The APR1400 has two identical steam generators and the generated steam from each steam generator is collected in the common header and delivered to the turbine. In the nodalization of the APR1400, the steam generator is divided into the downcomer, economizer, evaporator and

4 riser, separator, steam dryer, and steam dome. 4.Safety Injection System As previously described, the APR1400 adopts the direct vessel injection method for the safety system. The safety injection system has four mechanically separated hydraulic trains. Each hydraulic train, is composed of a High Pressure Safety Injection Pump (SIP) and a Safety Injection Tank (SIT), which is connected to the nozzle located at 2 m above the centerline of the cold legs. The nozzle also has the extended duct into the lower downcomer annulus. In the present analysis, two trains of ECCS are considered under the single failure assumption (two SIPs are available) and the nodalizations for the ECCS of the APR Initial and Boundary Condition To simulate the transient phenomena, 102% of the normal power and 1.2 times decay power of the ANS'73 decay heat model are used in the prototype calculation. For the cold leg double-ended guillotine break, the break position is assumed to be at the pump discharge line. To simulate the break flow, two junctions from the pump side and vessel side, respectively, to the atmosphere are configured in the nodalization for the transient calculation. In the transient calculation, the containment pressure is assumed to be atmospheric pressure. IV. Results and Discussion 1. LBLOCA After the LBLOCA is initiated, the primary system pressure of the APR1400 is precipitously dropped, as shown in Fig.7(a), as the blowdown phase, and maintains the low primary pressure condition. As the emergency core cooling (ECC) water is actuated to inject, the core level is recovered by the safety injection tank flow as shown in Fig. 7(b). The fuel cladding temperature reaches the peak values during the reflood phase. The collapsed water level of the core is strongly dependent on the liquid entrainment of the ECC bypass in the downcomer. To continue the high downcomer water level, the ECC extension duct has the role of ECC water protector in the upper downcomer and cold leg nozzles region for ECC penetration to the lower down comer. Fig.7 shows the thermal-hydraulic responses using the ECC extension duct for the reflood phase of the LBLOCA, especially. The results show that the extension duct contributes to a high water level in the downcomer and core cooling. The comparison results are summarized in Table.1. As shown in Fig.7(a), the subcooling degree of coolant at the lower downcomer is much enhanced by the extension duct because the ECC water does not heat up by high temperature steam in the downcomer. The extension duct prevents the steam-water interaction in the downcomer. The core reflood rate is maintained by the increased subcooling degree of the coolant in the lower downcomer without downcomer boiling during the late reflood phase of LBLOCA. But, the additional head of the extension duct in the downcomer does not contribute to the pressure of the downcomer. If the liquid entrainment in the downcomer is mitigated sufficiently by the extension duct, the increased downcomer water level affects the void fraction or quality of the upstream condition of the break. As shown in Fig.7(b), the break flow is a little distorted. As shown in Fig.7(c), the water level of the downcomer shows that the extension duct is a very useful tool to maintain the DC water level by mitigating the steam-water interaction in the downcomer. For the first stage of the refill phase, the water level of the downcomer is refilled very fast by the SIT high flow, and maintains the high liquid level until the SIT is empty. The core reflood rate is governed by the collapsed water level of the downcomer during the reflood phase of the LBLOCA, and dependent on the ECC penetration rate and ECC bypass rate. If the ECC bypass in the downcomer is mitigated well by adapting the extension duct of the nozzle, the liquid level of the downcomer may increase up to the onset-of-sweep out liquid level during the period of SIT activation. The liquid level of the downcomer is governed by the sweep out near the broken cold leg. The excessive SIT flow above the sweep out level goes out through the break. However, the degree of subcooling and liquid level is governed by ECC bypass during the reflood phase. As shown in Fig.7(c) and (d), the extension duct increases the collapsed water level of the downcomer and core to about 2 m higher than that of the typical nozzle without any extension part. As shown in Fig.7(e), the peak cladding temperature in case of the typical nozzle shows the late reheating during the reflood phase after about 1600 seconds because the downcomer water level is much decreased due to the liquid entrainment in the downcomer. However, for the case of the installed extension duct, the reflood peak cladding temperature has much lower values compared to those of the typical case. Furthermore, late reheating during the reflood phase does not appear when the extension duct is used. The extension duct of the nozzle may increase the subcooling degree of the coolant in the lower downcomer because the ECC water does not heat up by the steam when the ECC water flows down. Thus downcomer boiling during the late reflood phase of the LBLOCA does not occur when the extension duct is used as a part of ECC system with. As shown in Fig.7(f), the safety injection flows are not different from the two injection types. The fluidic device model is applied in the injection flow rate, thus the high safety injection flow continues to about 200 sec. The downcomer water level is maintained at high level during the SIT activation. 2. Line Break 2.1 Elevation Effect : High and Low Downcomer The effect of the elevation of the nozzle is investigated under the same conditions except the elevation of the nozzle in the downcomer. After the line break is initiated, the primary system pressure dropped to a saturation condition of about 8 MPa, and maintains twophase blowdown in the saturation condition. As the primary coolant is further leaked out, the pressure curves show the

5 gradual decrease and secondary plateau at about 2MPa as shown in Fig.8(a). The pressure trends with respect to time agree well with each other before SIT initiation at 200 seconds. However, the pressure of the lower nozzle is lower than that of the high nozzle during the reflood phase after 300~400 seconds. : Typical (APR1400) : Extension Duct (e) Cladding temperature (a) Subcooling degree at lower downcomer Rx Side : No Ext. Rx Side : Ext. Pump Side : No Ext. Pump Side : Ext (b) Break flow rate (c) Collapsed D/C water level (d) Collapsed core water level Fig. 7 (f) SI flow rate LBLOCA transient for a typical nozzle (No. Ext.) vs. a simply extended nozzle. The break flowrate has a similar trend except for some perturbation around 400 seconds. This fluctuation means that the upstream of the break located at the lower downcomer is changed to a single phase by the SIT high injection flow. As shown in Fig.8(c), the water level of the downcomer shows that the coolant flows out the break nozzle in the lower downcomer. The DC water level is decreased with a level difference between the two nozzles in high and low elevation. For the first stage of the SIT discharge phase, the water level of the downcomer is refilled for a very short period by the SIT high flow. However, the liquid level of the downcomer is decreased by the sweep out phenomena near the broken nozzle. Thus the liquid level of the downcomer does not go up above the cold leg under the condition of the same HPSI flow. As shown in Fig.8(c) and (d), the water level of the downcomer and core in case of the lower nozzle is about lower 2~3 m than that of the high level nozzle without an extension part during the late reflood phase of the line break. However, the typical high nozzle maintained a high water level during the reflood phase of the line break. As shown in Fig.8(e), the peak cladding temperature of the low nozzle shows late reheating during the late reflood phase after about 1600 seconds because the downcomer water level is decreased by the low water level of the downcomer. However, for the case of the high, the reflood peak cladding temperature has wetted values compared to those of the low case.

6 As shown in Fig.8(f), the HPSI flows are not so different from two injection types. The downcomer water level is maintained by HPSI injection during the reflood phase. But, the HPSI flows are not so different for the two cases. Thus, the low downcomer water level is caused by the elevation of the nozzle in the low system. (d) Collapsed core water level (a) Pressurizer pressure (b) Break flow rate (c) Collapsed D/C water level Fig. 8 (e) Cladding temperature (f) SI flow rate line break transient for high and low level elevation of nozzle 2.2 Effect Of The Top Vent Hole of The Extension Duct To investigate the effect of the top vent hole of the extension duct in preventing the inlet-to-outlet switching of the extension duct, three types of the nozzles are considered. The first case is for a typical nozzle, which is installed at the upper downcomer in the APR1400 plant. The index of the first case is "No Ext." in Fig. 9. The elevation of the nozzle is the upper downcomer. The second case is for the extension duct of the nozzle into the lower downcomer. The extension duct has two exits at both the top and bottom. The bottom exit is for the ECC injection phase, and the top exit is for the steam suction for the line break. The index of the second case is "exit. with top hole" in Fig.9. The elevation of the exit for the ECC injection is the lower downcomer. Lastly, the third case is for the simple extension pipe without a top hole. The index of the third case is "Simple Ext." in Fig.9. The elevation of the nozzle is the lower downcomer. Thus, the static head in the extension duct may exist for the second case and the third case if the extension duct is filled with a liquid or two phase during the discharge phase including the break phase of the line break accident. In the simple extension duct as a pipe, the discharge outlet has the role of a break suction inlet when the line break occurs. Thus the exit in the downcomer during the discharge phase switches into the break suction inlet during the line break. The inlet-to-outlet switching of

7 the extension duct is the major phenomena in this test. Only in the simplified extension pipe, the inlet-to-outlet switching phenomenon occurs for the line break, not in the extension duct with a top vent hole. After the line break is initiated, the primary system pressure dropped to a saturation condition of about 8 MPa, and gradually decreases at about 2MPa as shown in Fig.9(a). The pressure trends with respect to time agree well with each other before the SIT initiated at around 200 seconds. However, the pressure of the simple extension nozzle is lower than that of the no extension nozzle during the reflood phase after 300~400 seconds. The ECC injection flowrate of the simple extension nozzle will becomes larger than that of the no extension nozzle because the system pressure is low as shown in Fig. 9(a). The break flowrate has a similar trend except some perturbation around 300~600 seconds. This fluctuation indicates that the upstream of the break node, located at the lower downcomer, is under the condition of a two-phase discharge condition. The safety injection water fills the downcomer from the bottom. Thus, the flow condition of the break suction in the lower downcomer is changed more easily to a two-phase or single-phase liquid from the steam condition after the refill phase than the other cases. Therefore, the break flow of the third case of the simple extension is higher than those of the other two cases. In the case of the top hole, the steam in the upper downcomer is mainly discharged because of the difference in the static head of the extension duct. Thus, the break flow rate in case of the no extension duct shows a trend nearly similar to the case of the extension duct with the top hole. As shown in Fig.9(c), the water level of the downcomer shows that the third case using a simple extension pipe without a top hole is much lower than those of the other cases. Fig.9(c) also shows that the effect of the inlet-tooutlet switching of the extension duct occurs during the line break. The collapsed water level of the downcomer is strongly dependent on the location of the break suction in the downcomer during the line break. As shown in Fig.9(e), the collapsed water level of the core has the similar trends with the downcomer water levels. The water level of the core for the third case with a simple extension pipe is lower than 3 m. The HPSI flows are not so different according to the injection types as shown in Fig.9(f). Therefore, the low water level is caused by inletto-outlet switching phenomena of the simplified extension pipe in the lower downcomer. As shown in Fig.9(e), the peak cladding temperature for the third case with a simple extension nozzle is heated up from the early reflood phase because the downcomer water level is decreased by the break suction in the lower downcomer for the break flow. However, for the case of the second one with the extension duct with the top hole, the cladding temperature shows continuously the wetted values during the reflood phase. The comparison results are summarized in Table 1. (a) Pressurizer pressure (b) Break flow rate (c) Collapsed D/C water level (d) Collapsed core water level

8 (e) Cladding temperature (f) SI flow rate No Ext.(High ) Ext. with top hole Simple Ext. Fig. 9 Line break ; No Ext. for Typical Type; Ext. for extension duct with vent hole; Simple Ext. for a simplified extension nozzle. Table 1 Comparison results for Types during the line break. The ECC penetration duct is installed from the nozzle at the upper downcomer to the lower downcomer. The shape of an advanced extension duct, which has two exits at both the top and bottom of the duct, was considered to prevent inlet-to-outlet switching of the extension duct during the line break. A vent hole is considered at the top of the ECC penetration duct for a role of break suction at the upper downcomer. The break flow is initiated at both holes during the blowdown phase. But, the major break flow is switched from the bottom exit of the duct to the vent hole at the top of duct caused by the difference in the static head. The results show that the new ECC penetration duct having a vent hole at the top of the duct is a very useful design for both the reflood phase of LBLOCA and the line break. The late reheating during the reflood phase of a LBLOCA was successfully prevented by extension duct having a top vent hole. In the extended duct without vent holes, however, the reflood PCT exceeds the limit value of 1200K for the low downcomer water level caused by the outlet-to-suction inlet switching of the simplified extension pipe into the lower downcomer during the line break even though its a useful tool in preventing the steam-water interaction during the refoold phase of the LBLOCA. The collapsed water level both at the downcomer and core is also very low compared to those of the typical type of the nozzle. Acknowledgment This research has been performed as a part of the nuclear R&D program supported by the Ministry of Commerce, Industry and Energy (MCIE) of the Korean government. V. Conclusion References 1) KEPCO, Standard Safety Analysis Report for Korean Next Generation Reactor, KEPCO report (1999). 2) Y. J. Chung et al. Test Requirements for the KNGR ECCS Performance Test, KAERI report, SA (1999). 3) C. H. Song et al., Scaling Analysis of the Integral Test Loop to Simulate Korean PWR Plants, KAERI/TR- 1783/2001, KAERI (2001). 4) J. J. Jeong et al., Development of a multi-dimensional Thermal-hydraulic System Code, MARS 1.3.1, Annals of Nuclear Energy, 26(18), (1999). The ECC penetration duct of the direct vessel injection () system for the emergency core cooling (ECC) system has been studied to prevent steam-water interaction in the downcomer which leads to increasing the ECC bypass fraction during the late reflood phase of a large break loss-of-coolant accident (LBLOCA), and to prevent the collapsed water level which is usually decreasing

Hydrodynamics of ECC Water Bypass and Refill of Lower Plenum at PWR-LOCA

Hydrodynamics of ECC Water Bypass and Refill of Lower Plenum at PWR-LOCA Journal of Nuclear Science and Technology SSN: 22-3131 (Print) 1881-1248 (Online) Journal homepage: http://www.tandfonline.com/loi/tnst2 Hydrodynamics of ECC Water Bypass and Refill of Lower Plenum at

More information

International Standard Problem No. 43: Results and Lessons Learned. Abstract

International Standard Problem No. 43: Results and Lessons Learned. Abstract International Standard Problem No. 43: Results and Lessons Learned Mirela Gavrilas United States Nuclear Regulatory Commission, Office of Nuclear Regulatory Research Abstract In 1997, OECD/CSNI approved

More information

THE DESIGN OF A LEAD-BISMUTH TARGET SYSTEM WITH A DUAL INJECTION TUBE

THE DESIGN OF A LEAD-BISMUTH TARGET SYSTEM WITH A DUAL INJECTION TUBE THE DESIGN OF A LEAD-BISMUTH TARGET SYSTEM WITH A DUAL INJECTION TUBE Chungho Cho, Yonghee Kim, Tae Yung Song, Won Seok Park Korea Atomic Energy Research Institute, Korea Abstract A spallation target system

More information

HIGH RESOLUTION THERMAL MIXING AT WESTINGHOUSE ODEN LOOP

HIGH RESOLUTION THERMAL MIXING AT WESTINGHOUSE ODEN LOOP HIGH RESOLUTION THERMAL MIXING AT WESTINGHOUSE ODEN LOOP L. David Smith, III Westinghouse Electric Company, Hopkins, SC, USA smith1ld@westinghouse.com Paul F. Joffre Westinghouse Electric Company, Windsor,

More information

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron Available online www.ejaet.com European Journal of Advances in Engineering and Technology, 2014, 1(1): 11-15 Research Article ISSN: 2394-658X Design, Fabrication and Testing of Gun-Collector Test Module

More information

The PEFP 20-MeV Proton Linear Accelerator

The PEFP 20-MeV Proton Linear Accelerator Journal of the Korean Physical Society, Vol. 52, No. 3, March 2008, pp. 721726 Review Articles The PEFP 20-MeV Proton Linear Accelerator Y. S. Cho, H. J. Kwon, J. H. Jang, H. S. Kim, K. T. Seol, D. I.

More information

TOSHIBA Industrial Magnetron E3328

TOSHIBA Industrial Magnetron E3328 TOSHIBA E3328 is a fixed frequency continuous wave magnetron intended for use in the industrial microwave heating applications. The average output power is 3kW in the frequency range from 2450 to 2470

More information

NEXT ION OPTICS SIMULATION VIA ffx

NEXT ION OPTICS SIMULATION VIA ffx 39 th Joint Propulsion Conference Huntsville, Alabama, 0-3 July 003 AIAA 003-4869 NEXT ION OPTICS SIMULATION VIA ffx Cody C. Farnell,* John D. Williams, and Paul J. Wilbur Colorado State University Fort

More information

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator Stanley Humphries, Copyright 2012 Field Precision PO Box 13595, Albuquerque, NM 87192 U.S.A. Telephone: +1-505-220-3975

More information

Development of a GUI-Based RETRAN Running Environment

Development of a GUI-Based RETRAN Running Environment INSIDE Featured Articles GUI-Based RETRAN... 1 OECD/NEA Analysis... 2 User Group Meeting... 3 Published by Computer Simulation & Analysis, Inc. for EPRI In Every Issue From the Editor... 3 R2 Trouble Reports...

More information

Does Feng-Shui Approach Improve The Indoor Environment Quality? The Viewpoint of The Toom Ventilation by CFD Simulation

Does Feng-Shui Approach Improve The Indoor Environment Quality? The Viewpoint of The Toom Ventilation by CFD Simulation Does Feng-Shui Approach Improve The Indoor Environment Quality? The Viewpoint of The Toom Ventilation by CFD Simulation Po-Cheng Chou 1, Chiu-Chi Hung 1, Che-Ming Chiang 2 ¹ Dept. of Interior Design, Shu-Te

More information

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow ...Simple Effective Inexpensive to operate Economical The Saudi Factory for Air Conditioning Units No air cooled condenser needed No chiller or cooling tower needed No major control center No refrigerant

More information

Ultra-Short Radius Multi Laterals For Improved Steam Distribution and Production

Ultra-Short Radius Multi Laterals For Improved Steam Distribution and Production Ultra-Short Radius Multi Laterals For Improved Steam Distribution and Production The SAGD Dream Clean sand Symmetric steam chamber development http://history.alberta.ca/energyheritage/images/content/sands/utf_sagd_diagram_ab_innovates.jpg

More information

ALDEN COMPUTATIONAL ANALYSIS OF WESTFALL S OPEN CHANNEL MIXER FOR THE COLBORNE SEWAGE TREATMENT PLANT. Solving Flow Problems Since 1894

ALDEN COMPUTATIONAL ANALYSIS OF WESTFALL S OPEN CHANNEL MIXER FOR THE COLBORNE SEWAGE TREATMENT PLANT. Solving Flow Problems Since 1894 Solving Flow Problems Since 1894 COMPUTATIONAL ANALYSIS OF WESTFALL S OPEN CHANNEL MIXER FOR THE COLBORNE SEWAGE TREATMENT PLANT Alden Report No: By: Kimbal Hall, PE Submitted to: Bob Glanville Westfall

More information

Screw pump Series ALLFUEL AFT

Screw pump Series ALLFUEL AFT Screw pump Series ALLFUEL AFT Utilization For pumping light and heavy fuel oil. Main field of application ALLFUEL Transfer (AFT) pumps are compact pump sets designed for closed circuit and transfer applications

More information

WAH WANG HOLDINGS (HONG KONG) CO., LTD.

WAH WANG HOLDINGS (HONG KONG) CO., LTD. Wah Wang Data Sheet For 5mm Super Flux White LED High Reliable Type High Power 3 LED Chips Series RF-M05V53WUR4-B4-Q Address : Unit C, D & E, 12/F., Po Shau Centre, No. 115 How Ming Street Kwun Tong, Kowloon,

More information

PEP-I1 RF Feedback System Simulation

PEP-I1 RF Feedback System Simulation SLAC-PUB-10378 PEP-I1 RF Feedback System Simulation Richard Tighe SLAC A model containing the fundamental impedance of the PEP- = I1 cavity along with the longitudinal beam dynamics and feedback system

More information

Interactive Virtual Laboratory for Distance Education in Nuclear Engineering. Abstract

Interactive Virtual Laboratory for Distance Education in Nuclear Engineering. Abstract Interactive Virtual Laboratory for Distance Education in Nuclear Engineering Prashant Jain, James Stubbins and Rizwan Uddin Department of Nuclear, Plasma and Radiological Engineering University of Illinois

More information

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist Agilent Site Preparation InfinityLab Checklist LC Series Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification

More information

Adebutaniser in BP s FCC unit

Adebutaniser in BP s FCC unit Better feed entry ups debutaniser capacity Points of transition, where streams enter or leave the tower, are some of the most common and severe tower bottlenecks. Combining hydraulic evaluation with field

More information

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit. EVF 300 series Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit. Installer manual ENGLISH Code 144F300E114 Page 1 of 62 Important

More information

UNITY 2 TM. Version 1.0. February 2008

UNITY 2 TM. Version 1.0. February 2008 UNITY 2 TM ULTRA 50:50 Operators Manual Version 1.0 February 2008 1. Loading tubes onto ULTRA 50:50...3 1.1. DiffLok analytical end caps for sample tubes...3 1.2. Capping tubes with DiffLok caps...3 1.3.

More information

Testing and Characterization of the MPA Pixel Readout ASIC for the Upgrade of the CMS Outer Tracker at the High Luminosity LHC

Testing and Characterization of the MPA Pixel Readout ASIC for the Upgrade of the CMS Outer Tracker at the High Luminosity LHC Testing and Characterization of the MPA Pixel Readout ASIC for the Upgrade of the CMS Outer Tracker at the High Luminosity LHC Dena Giovinazzo University of California, Santa Cruz Supervisors: Davide Ceresa

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST FANS. Model TVIFE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST FANS. Model TVIFE TURNING AIR INTO SOLUTIONS. 60 2 CA AM ted tes DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST S Model TVIFE CATALOG 1090 September 2016 LABORATORY EXHAUST S Overview TVIFE TVIFE Single Unit Twin City Fan

More information

The RETRAN. N e w s l e t t e r. Steering Committee for RETRAN Maintenance Group. September, Summary of Activities

The RETRAN. N e w s l e t t e r. Steering Committee for RETRAN Maintenance Group. September, Summary of Activities The RETRAN Published by Computer Simulation & Analysis, Inc. for the Electric Power Research Institute N e w s l e t t e r September, 1996 Summary of Activities This issue of the RETRAN Newsletter contains

More information

Application of the Hollow Cathode to DC Arcjet

Application of the Hollow Cathode to DC Arcjet Application of the Hollow Cathode to DC Arcjet IEPC-213-243 Presented at the 33rd International Electric Propulsion Conference, The George Washington University Washington, D.C. USA Masahiro Kinoshita.

More information

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh Design and Simulation of High Power RF Modulated Triode Electron Gun A. Poursaleh National Academy of Sciences of Armenia, Institute of Radio Physics & Electronics, Yerevan, Armenia poursaleh83@yahoo.com

More information

A New 4MW LHCD System for EAST

A New 4MW LHCD System for EAST 1 EXW/P7-29 A New 4MW LHCD System for EAST Jiafang SHAN 1), Yong YANG 1), Fukun LIU 1), Lianmin ZHAO 1) and LHCD Team 1) 1) Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, China E-mail

More information

Hollow Cathode and Thruster Discharge Chamber Plasma Measurements Using High-Speed Scanning Probes

Hollow Cathode and Thruster Discharge Chamber Plasma Measurements Using High-Speed Scanning Probes Hollow Cathode and Thruster Discharge Chamber Plasma Measurements Using High-Speed Scanning Probes IEPC--69 Presented at the 9 th International Electric Propulsion Conference, Princeton University, Kristina

More information

Bartels Micropumps. ( ) Rev. 2.8

Bartels Micropumps. ( ) Rev. 2.8 EN Bartels Micropumps Micropumps transporting the tiniest amounts of gases or liquids can be considered the heart of microfluidics. In many sectors they have become indispensable. Dosing lubricants, feeding

More information

Simulation of DFIG and FSIG wind farms in. MATLAB SimPowerSystems. Industrial Electrical Engineering and Automation.

Simulation of DFIG and FSIG wind farms in. MATLAB SimPowerSystems. Industrial Electrical Engineering and Automation. CODEN:LUTEDX/(TEIE-7235)/1-007/(2009) Industrial Electrical Engineering and Automation Simulation of DFIG and FSIG wind farms in MATLAB SimPowerSystems Francesco Sulla Division of Industrial Electrical

More information

Mechanical Considerations in the Outer Tracker and VXD. Bill Cooper Fermilab

Mechanical Considerations in the Outer Tracker and VXD. Bill Cooper Fermilab Mechanical Considerations in the Outer Tracker and VXD Fermilab August 23, 2005 1 Overview I ll describe developments since the SLAC workshop in mechanical design efforts at Fermilab related to SiD tracking.

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual LAM490 AutoEtch System Copyright 11.2015 by Hong Kong University of Science & Technology. All rights reserved. Page 1 Contents 1. Picture and Location 2. Process Capabilities

More information

BTC and SMT Rework Challenges

BTC and SMT Rework Challenges BTC and SMT Rework Challenges Joerg Nolte Ersa GmbH Wertheim, Germany Abstract Rising customer demands in the field of PCB repair are a daily occurrence as the rapid electronic industry follows new trends

More information

Accuracy improvement of indenting test results by using wireless cable indenting robot

Accuracy improvement of indenting test results by using wireless cable indenting robot Journal of Mechanical Science and Technology 6 (9) (0) 7~70 www.springerlink.com/content/78-9x DOI 0.007/s06-0-070-9 Accuracy improvement of indenting test results by using wireless cable indenting robot

More information

New Results on the Electron Cloud at the Los Alamos PSR

New Results on the Electron Cloud at the Los Alamos PSR New Results on the Electron Cloud at the Los Alamos PSR Robert Macek, LANL, 4/15/02 Co-authors: A. Browman, D. Fitzgerald, R. McCrady, T. Spickermann, & T. S. Wang - LANL For more information see the website

More information

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator 3.635.5275.254 IM-P486-18 CH Issue 3 PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator Installation, Start-up and Operation Manual 1. Safety information 2. General product information

More information

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions LMG257-185XTN Introduction 18.5" Sunlight Readable LCD Module The LMG257-185XTN is a 18.5" Sunlight Readable LCD module. The module consists of an AUO M185XTN01.2 TFT color LCD panel and a VHB (very high

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

Lecture 17 Microwave Tubes: Part I

Lecture 17 Microwave Tubes: Part I Basic Building Blocks of Microwave Engineering Prof. Amitabha Bhattacharya Department of Electronics and Communication Engineering Indian Institute of Technology, Kharagpur Lecture 17 Microwave Tubes:

More information

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) 172.02.02 Excerpt from the Product Section C02 Edition March 2007 Contents General Product Range, Features and

More information

Karl Heinz Feller. Arbeitsgruppe Instrumentelle Analytik FB Medizintechnik und Biotechnologie Ernst-Abbe-Fachhochschule Jena.

Karl Heinz Feller. Arbeitsgruppe Instrumentelle Analytik FB Medizintechnik und Biotechnologie Ernst-Abbe-Fachhochschule Jena. CFD Simulationen von mikrofluidischen Bauelementen zur Optimierung von chemischen Reaktionen Karl Heinz Feller Arbeitsgruppe Instrumentelle Analytik FB Medizintechnik und Biotechnologie Ernst-Abbe-Fachhochschule

More information

MODFLOW - Grid Approach

MODFLOW - Grid Approach GMS 7.0 TUTORIALS MODFLOW - Grid Approach 1 Introduction Two approaches can be used to construct a MODFLOW simulation in GMS: the grid approach and the conceptual model approach. The grid approach involves

More information

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline 3 cerl 3-1 cerl Overview As described before, the aim of the cerl in the R&D program includes the development of critical components for the ERL, as well as the construction of a test accelerator. The

More information

RELIABLE LED-LIT DLP REAR-PROJECTION CUBES PERFECT VISUAL SOLUTIONS

RELIABLE LED-LIT DLP REAR-PROJECTION CUBES PERFECT VISUAL SOLUTIONS RELIABLE LED-LIT DLP REAR-PROJECTION CUBES PERFECT VISUAL SOLUTIONS OUR eccube SERIES DEVELOPED FOR DEMANDING APPLICATIONS: SOLUTIONS FOR CONTROL SOLUTIONS FOR PRESENTATION & INFORMATION SOLUTIONS FOR

More information

Guided Wave Radar Level Meter

Guided Wave Radar Level Meter Guided Wave Radar Level Meter Guided Wave Radar Level Meter Instruction 1. Product Description 1.1 principle of measurement Guided Wave Radar is the measuring instruments that based on the time travel

More information

SOC Implementation for Christmas Lighting with Pattern Display Indication RAMANDEEP SINGH 1, AKANKSHA SHARMA 2, ANKUR AGGARWAL 3, ANKIT SATIJA 4 1

SOC Implementation for Christmas Lighting with Pattern Display Indication RAMANDEEP SINGH 1, AKANKSHA SHARMA 2, ANKUR AGGARWAL 3, ANKIT SATIJA 4 1 1016 SOC Implementation for Christmas Lighting with Pattern Display Indication RAMANDEEP SINGH 1, AKANKSHA SHARMA 2, ANKUR AGGARWAL 3, ANKIT SATIJA 4 1 Assistant Professor, Department of EECE, ITM University,

More information

SWITCHED INFINITY: SUPPORTING AN INFINITE HD LINEUP WITH SDV

SWITCHED INFINITY: SUPPORTING AN INFINITE HD LINEUP WITH SDV SWITCHED INFINITY: SUPPORTING AN INFINITE HD LINEUP WITH SDV First Presented at the SCTE Cable-Tec Expo 2010 John Civiletto, Executive Director of Platform Architecture. Cox Communications Ludovic Milin,

More information

v. 8.0 GMS 8.0 Tutorial MODFLOW Grid Approach Build a MODFLOW model on a 3D grid Prerequisite Tutorials None Time minutes

v. 8.0 GMS 8.0 Tutorial MODFLOW Grid Approach Build a MODFLOW model on a 3D grid Prerequisite Tutorials None Time minutes v. 8.0 GMS 8.0 Tutorial Build a MODFLOW model on a 3D grid Objectives The grid approach to MODFLOW pre-processing is described in this tutorial. In most cases, the conceptual model approach is more powerful

More information

800 Displaying Series Flowmeter

800 Displaying Series Flowmeter TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially

More information

Measurement of overtone frequencies of a toy piano and perception of its pitch

Measurement of overtone frequencies of a toy piano and perception of its pitch Measurement of overtone frequencies of a toy piano and perception of its pitch PACS: 43.75.Mn ABSTRACT Akira Nishimura Department of Media and Cultural Studies, Tokyo University of Information Sciences,

More information

MAMX Sub-Harmonic Pumped Mixer GHz Rev. V1. Functional Schematic. Features. Description. Pin Configuration 1

MAMX Sub-Harmonic Pumped Mixer GHz Rev. V1. Functional Schematic. Features. Description. Pin Configuration 1 MAMX-119 Features Up or Down Frequency Mixer Low Conversion Loss: 11 db 2xLO & 3xLO Rejection: db RF Frequency: 14 - LO Frequency: 4-2 GHz IF Frequency: DC - 7 GHz Lead-Free 1.x1.2 mm 6-lead TDFN Package

More information

CPI Gyrotrons For Fusion EC Heating

CPI Gyrotrons For Fusion EC Heating CPI Gyrotrons For Fusion EC Heating H. Jory, M. Blank, P. Borchard, P. Cahalan, S. Cauffman, T. S. Chu, and K. Felch CPI, Microwave Power Products Division 811 Hansen Way, Palo Alto, CA 94303, USA e-mail:

More information

Model Identification of Displacement Controlled Linear Actuator in Hydraulic System

Model Identification of Displacement Controlled Linear Actuator in Hydraulic System Journal of Engineering Science and Military Technologies ISSN: 4530-7532 DOI:10.21608/ejmtc.2017.1415.1057 Model Identification of Displacement Controlled Linear Actuator in Hydraulic System Original Article

More information

44 th Annual Canadian Mineral Processors Operators Conference Ottawa, Ontario, January 17-19, 2012

44 th Annual Canadian Mineral Processors Operators Conference Ottawa, Ontario, January 17-19, 2012 44 th Annual Canadian Mineral Processors Operators Conference Ottawa, Ontario, January 17-19, 2012 SECONDARY RECOVERY OF BITUMEN USING JAMESON DOWNCOMERS *O. Neiman 1, B. Hilscher 1, R. Siy 2 1 Syncrude

More information

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267 TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267 The company was created for the development and manufacture of precision microwave vacuum-electron-tube devices (VETD). The main product areas

More information

Performance Characteristics of Steady-State MPD Thrusters with Permanent Magnets and Multi Hollow Cathodes for Manned Mars Exploration

Performance Characteristics of Steady-State MPD Thrusters with Permanent Magnets and Multi Hollow Cathodes for Manned Mars Exploration Performance Characteristics of Steady-State MPD Thrusters with Permanent Magnets and Multi Hollow Cathodes for Manned Mars Exploration IEPC-2015-197 /ISTS-2015-b-197 Presented at Joint Conference of 30th

More information

Compressor rub verified by rotating phase symptoms

Compressor rub verified by rotating phase symptoms Compressor rub verified by rotating phase symptoms Nicolas Péton, Charles Grislin 1 and Guillame Christin 2 1 GE Measurement and Control, 14 rue de la Haltinière, 44303 Nantes, France 2 GE Measurement

More information

THE DIGITAL DELAY ADVANTAGE A guide to using Digital Delays. Synchronize loudspeakers Eliminate comb filter distortion Align acoustic image.

THE DIGITAL DELAY ADVANTAGE A guide to using Digital Delays. Synchronize loudspeakers Eliminate comb filter distortion Align acoustic image. THE DIGITAL DELAY ADVANTAGE A guide to using Digital Delays Synchronize loudspeakers Eliminate comb filter distortion Align acoustic image Contents THE DIGITAL DELAY ADVANTAGE...1 - Why Digital Delays?...

More information

SURFACE MOUNT LED LAMP STANDARD BRIGHT PLCC-2

SURFACE MOUNT LED LAMP STANDARD BRIGHT PLCC-2 PACKAGE DIMENSIONS 0.130 (3.3) 0.114 (2.9) Ø0.094 [Ø2.4] 0.118 (3.0) 0.102 (2.6) 0.091 (2.3) 0.083 (2.1) TOP POLARITY MARK 0.024 (0.6) 0.016 (0.4) 0.083 (2.1) 0.067 (1.7) 0.146 (3.7) 0.130 (3.3) SIDE 0.006

More information

Simulation of Micro Blanking Process of Square Hole with Fillet Based on DEFORM-3D

Simulation of Micro Blanking Process of Square Hole with Fillet Based on DEFORM-3D 3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015) Simulation of Micro Blanking Process of Square Hole with Fillet Based on DEFORM-3D Shining Zhou 1,a, Xiaolong

More information

45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests*

45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests* US High Gradient Research Collaboration Workshop. SLAC, May 23-25, 2007 45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests* V.P. Yakovlev 1, S.Yu. Kazakov 1,2, and J.L. Hirshfield 1,3 1

More information

DIFFERENTIAL CONDITIONAL CAPTURING FLIP-FLOP TECHNIQUE USED FOR LOW POWER CONSUMPTION IN CLOCKING SCHEME

DIFFERENTIAL CONDITIONAL CAPTURING FLIP-FLOP TECHNIQUE USED FOR LOW POWER CONSUMPTION IN CLOCKING SCHEME DIFFERENTIAL CONDITIONAL CAPTURING FLIP-FLOP TECHNIQUE USED FOR LOW POWER CONSUMPTION IN CLOCKING SCHEME Mr.N.Vetriselvan, Assistant Professor, Dhirajlal Gandhi College of Technology Mr.P.N.Palanisamy,

More information

Broken Wires Diagnosis Method Numerical Simulation Based on Smart Cable Structure

Broken Wires Diagnosis Method Numerical Simulation Based on Smart Cable Structure PHOTONIC SENSORS / Vol. 4, No. 4, 2014: 366 372 Broken Wires Diagnosis Method Numerical Simulation Based on Smart Cable Structure Sheng LI 1*, Min ZHOU 2, and Yan YANG 3 1 National Engineering Laboratory

More information

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION. Soft Starter Catalog 2018 Release n.

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION.   Soft Starter Catalog 2018 Release n. 380 to 600V Nominal current 6 to 200A ST with Soft Start STO with Soft Start + Overload Relay Internal by pass relay SOFT STARTER CD AUTOMATION POWERED BY INNOVATION We are delivering Real Cost Benefits

More information

Preliminary Study on Radio Frequency Neutralizer for Ion Engine

Preliminary Study on Radio Frequency Neutralizer for Ion Engine Preliminary Study on Radio Frequency Neutralizer for Ion Engine IEPC-2007-226 Presented at the 30 th International Electric Propulsion Conference, Florence, Italy Tomoyuki Hatakeyama *, Masatoshi Irie

More information

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications Reliability Guideline: Generating Unit Operations During Complete Loss of Communications Preamble It is in the public interest for the North American Electric Reliability Corporation (NERC) to develop

More information

CM MTC PARTS LIST

CM MTC PARTS LIST 8650 Enterprise Drive, Peosta IA 52068-0050 319-556-7484 / Fax 319-556-1235 CM-2400-0MTC PARTS LIST ENGINE OIL GRADE: ENGINE OIL CAPACITY: PUMP OIL: PUMP OIL CAPACITY: NOZZLE SIZE: 30W 21 oz. MI-T-M #AW-4085-0016

More information

Figure 2 Horizontal batch mixer data sheet Date: Name: Company: Address: Phone: Fax: Project Name: Material description: Material characterist

Figure 2 Horizontal batch mixer data sheet Date: Name: Company: Address: Phone: Fax:   Project Name: Material description: Material characterist What to consider when choosing a horizontal batch mixer Carl G. Ewing S. Howes Dry bulk solids mixing can be done with several kinds of mixers batch and continuous, horizontal and vertical, and agitated

More information

Steam Generator Tube Inspection I

Steam Generator Tube Inspection I Steam Generator Tube Inspection I Development of Smart Array Probe and Introduction of New Inspection System K. Maeda, J. Shimone, A. Nunoko, J. Akagawa, Y. Nagata, H. Izumida, Y. Harada, Nuclear Engineering,

More information

In batch mixing, ingredients are loaded into the mixer, the. What to consider when choosing a horizontal batch mixer

In batch mixing, ingredients are loaded into the mixer, the. What to consider when choosing a horizontal batch mixer As appeared in January 2011 PBE www.powderbulk.com What to consider when choosing a horizontal batch mixer Carl G. Ewing S. Howes Dry bulk solids mixing can be done with several kinds of mixers batch and

More information

AC05-76RL01830; NRC JCN N6398; Mr. Wallace Norris, Program Monitor.

AC05-76RL01830; NRC JCN N6398; Mr. Wallace Norris, Program Monitor. Developments in Ultrasonic Inspection II Ultrasonic Flaw Detection of Cracks and Machined Flawsas Observed through Austenitic Stainless Steel Piping Welds M.T. Anderson, A.D. Cinson, S.L. Crawford, S.E.

More information

Advanced Photon Source - Upgrades and Improvements

Advanced Photon Source - Upgrades and Improvements Advanced Photon Source - Upgrades and Improvements Horst W. Friedsam, Jaromir M. Penicka Argonne National Laboratory, Argonne, Illinois, USA 1. INTRODUCTION The APS has been operational since 1995. Recently

More information

CPD LED Course Notes. LED Technology, Lifetime, Efficiency and Comparison

CPD LED Course Notes. LED Technology, Lifetime, Efficiency and Comparison CPD LED Course Notes LED Technology, Lifetime, Efficiency and Comparison LED SPECIFICATION OVERVIEW Not all LED s are alike During Binning the higher the flux and lower the forward voltage the more efficient

More information

ITTC Recommended Procedures and Guidelines

ITTC Recommended Procedures and Guidelines Committee and Page 1 of 7 Table of Contents Committee and... 2 1. OVERVIEW... 2 2. MATERIALS... 2 2.1 Word Processing... 2 2.2 Confirmation... 2 3. PAGE GEOMETRY... 2 3.1 Top and Bottom Margins... 2 3.1.1

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 5.3 ACTIVE NOISE CONTROL

More information

Fluid Cooling P-BAR b Industrial BOL Series

Fluid Cooling P-BAR b Industrial BOL Series Fluid Cooling P-BAR b Industrial BOL Series 10 BRAZED ALUMINUM CONSTRUCTION Performance Notes Bar and plate brazed aluminum core Provides the best heat transfer per given envelope size while minimizing

More information

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist 1290 Site Preparation Infinity LC/1260 Checklist Infinity LC Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this

More information

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change without

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Complete Fine Beam Tube System 1013843 Instruction sheet 10/15 SD/ALF If it is to be expected that safe operation is impossible (e.g., in case of visible damage), the apparatus is

More information

SAFETY WARNINGS AND GUIDELINES

SAFETY WARNINGS AND GUIDELINES SAFETY WARNINGS AND GUIDELINES Please read this manual thoroughly, paying extra attention to these safety warnings and guidelines: Do not expose this monitor to water or moisture of any kind. Do not handle

More information

Highly Accelerated Stress Screening of the Atlas Liquid Argon Calorimeter Front End Boards

Highly Accelerated Stress Screening of the Atlas Liquid Argon Calorimeter Front End Boards Highly Accelerated Stress Screening of the Atlas Liquid Argon Calorimeter Front End Boards K. Benslama, G. Brooijmans, C.-Y. Chi, D. Dannheim, I. Katsanos, J. Parsons, S. Simion Nevis Labs, Columbia University

More information

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes Indian Journal of Pure & Applied Physics Vol. 53, April 2015, pp. 225-229 Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes Udit Narayan Pal a,b*, Jitendra Prajapati

More information

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance Table of Contents Introduction................................1 Axial pull test and horizontal shear test............2

More information

Series: BPV, BPLHS. Vertical Multi-Stage Family Curve, 3500 RPM - 60Hz. Family Curves. Vertical Multi-Stage Pumps.

Series: BPV, BPLHS. Vertical Multi-Stage Family Curve, 3500 RPM - 60Hz. Family Curves. Vertical Multi-Stage Pumps. Series:, BPLHS Family Curves Vertical Multi-Stage Family Curve, 3500 RPM - 60Hz. 1 5/11 Series: General Information The Burks Series is made up of pumps with all wetted parts made of stainless steel. For

More information

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments Dual line system Designed to work all the day, every day in extreme condition and difficult environments CONTENTS Applications 3 Description 4 Operation 5 Benefits 6 TWIN pump 7 TWIN measures 8 TWIN-PUMP

More information

WS2815 Intelligent control LED integrated light source

WS2815 Intelligent control LED integrated light source Features and Benefits The control circuit and RGB chip are integrated in a 5050 components, to form an external control pixel. 12V DC power supply, can effectively reduce the operating current of the pixel

More information

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling Commissioning the TAMUTRAP RFQ cooler/buncher E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling In order to efficiently load ions into a Penning trap, the ion beam should be

More information

1.5 GHz to 4.5 GHz, GaAs, MMIC, Double Balanced Mixer HMC213BMS8E

1.5 GHz to 4.5 GHz, GaAs, MMIC, Double Balanced Mixer HMC213BMS8E FEATURES Passive: no dc bias required Conversion loss: 1 db typical Input IP3: 21 dbm typical RoHS compliant, ultraminiature package: 8-lead MSOP APPLICATIONS Base stations Personal Computer Memory Card

More information

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) Central Vacuum Supply Systems 172.02.02 Excerpt from the Product Section C02 Edition 2010 Contents General Product

More information

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX: Operation is similar to standard centrifugal pumps, except the impeller is driven with a magnetic coupling, eliminating the need for a shaft seal. Magnetic drive pumps must be used where flooded suction

More information

Mounts Machinery Field IQ Manual for CFX/FM-750 Display (ver 2.0)

Mounts Machinery Field IQ Manual for CFX/FM-750 Display (ver 2.0) Mounts Machinery Field IQ Manual for CFX/FM-750 Display (ver 2.0) Setup, Calibration & Operation of Trimbles Field IQ Sprayer Control System, when used on the CFX-750 Display for Automatic Rate and Section

More information

Tray Specification. AlphaTRAY DESIGN SHEET. Standard Types: High Performance Types: DS-DT-01 Rev 3 OVERVIEW

Tray Specification. AlphaTRAY DESIGN SHEET. Standard Types: High Performance Types:  DS-DT-01 Rev 3 OVERVIEW OVERVIEW Conventional absorption, distillation or fractionating trays consist of vapour/liquid contacting decks or trays with segmented liquid downflow areas. Columns can contain any number of trays installed

More information

EAGLE RE-1 CONTROLLER

EAGLE RE-1 CONTROLLER EAGLE RE-1 CONTROLLER For Use On ALL MotoSAT Mounts Supported Systems HD SL5 DirecTV HD DP3 Dish Network HD SC2 SHAW HD DP3 BELL TV EXECUTIVE 18" DirecTV 101 Dish Network 119 MSC-60 SHAW MD-500 Dish Network

More information

Hitachi Kokusai Electric Comark LLC

Hitachi Kokusai Electric Comark LLC Hitachi Kokusai Electric Comark LLC TRANSMIT TER OF THE FUTURE Solid State. Broadband. Affordable. The future has arrived. With rapid changes in solid state RF device technologies and design techniques,

More information

Advanced Return Path Alignment & Maintenance Using the 9581 SST R4

Advanced Return Path Alignment & Maintenance Using the 9581 SST R4 Advanced Return Path Alignment & Maintenance Using Introduction The first step in developing a successful alignment and maintenance strategy for the return path depends on understanding what constitutes

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT A PLUS INDUSTRIES LIMITED. Plot-28, Milk Vita Rd., Section-07, Mirpur, Dhaka Factory List: 1. A Plus Industries Ltd. Inspected by: Yoon Report Generated by: Nezar Inspected

More information

Machinery Diagnostic Plots Part 1 ORBIT Back-to-Basics: What does the data really tell us?

Machinery Diagnostic Plots Part 1 ORBIT Back-to-Basics: What does the data really tell us? Machinery Diagnostic Plots Part 1 ORBIT Back-to-Basics: What does the data really tell us? Gaston Desimone Latin America Technical Leader Bently Nevada* Machinery Diagnostic Services (MDS) Buenos Aires

More information

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade The space-saving helper in filling stations, gastronomy and the trade The space-saving helper in the positive and negative range Straightforward mounting Integrated air baffle plate Extremely space-saving

More information

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION Cooled DFB Lasers in RF over Fiber Optics Applications BENEFITS SUMMARY Practical 10 db

More information