7 Lighting Technology
|
|
- Aleesha Caldwell
- 5 years ago
- Views:
Transcription
1 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection in accordance with EN and dust protection as per EN For use in Zone 2 Zone 21 and Zone 22 Max. possible lamp capacity high-pressure sodium lamps up to 600 W metal-halide lamps up to 400 W halogen lamps up to 1000 W Stainless steel housing, available in three sizes Broad or narrow beam reflectors and/or asymmetrical lamp fitting, Standard: broad beam Options (all stainless steel components) light visor, detachable: blocks light escape above and lateral from the unit baffle screen, detachable: prevents lateral eye contact (up to 45 ); also serves as a protective grating mounting base (rotatable): for permanent installation of the floodlight to walls and columns pole mounting attachment explosion protected floodlight as spotlight with asymmetrical flat optics reflector 7/1Zones 2, 21 & 22General Catalogue
2 Floodlight 7 Selection table Version Lamp capacity Temperature class at T a = Floodlight size 1 Floodlight size 2 Floodlight size 3 T o max. at T a= Lamps 1) Power 40 C 50 C T o at T a = 40 C Ordering code Weight E 27 E 27 max. 150 W max. T3 T2 T3 T2 155 C 200 C 6521/ ,400 High-pressure lamps E 27 HIT 70 W T4 T3 120 C 6521/ ,600 E W T3 120 C 6521/ ,600 E 27 HIT 100 W T3 T3 140 C 6521/ ,000 E 27 HIE 150 W T3 T2 165 C 6521/ ,070 E W T3 T3 180 C 6521/ ,200 High-pressure lamps E 40 HIT / 150 W T3 T3 140 C 6521/ ,400 E 40 HIT / T3 T3 145 C 6521/ ,900 E W T2 T2 230 C 6521/ ,200 High-pressure lamps E 40 HIT / E 40 HIT / T4 T4 125 C 6521/ , W T3 T3 160 C 6521/ ,300 E W T2 T2 190 C 6521/ ,900 Add. to ordering code Reflector, symmetrical Reflector, asymmetrical broad-beamed (standard) 6521/ broad-beamed 6521/ narrow-beamed 6521/ Compensation without 6521/ with 6521/ Cable entry standard: c) 3x M 20 x / x cable entry 1x stopping plug 1x cable entry with blind plugs as test holes kg special: c) 2x M 25 x 1.5 1x cable entry 1x stopping plug1x M 20 cable entry with blind plugsas test holes 6521/ other: Cable entries per customer order 6521/ Rated voltage Specify rated voltage Please pay attention to the information on the next page. 7/2
3 7 Floodlight Note 1) HIT HIT / Metal halide lamps High-pressure sodium lamps Metal halide lamps / High-pressure sodium lamps - The floodlights are delivered without lamps; mounting bracket is delivered standard. Additional mounting accessories must be ordered separately. - Cable gland M 20 x 1.5; connection range d 6 mm mm. Cable gland M 25 x 1.5; connection range d 10 mm mm. Technical Data Explosion protection Gas explosion protection Zone 2: E II 3 G EEx nr II T 1) Dust explosion protection Zone 21: E II 2 D IP 66 T O max. 1) Zone 22: E II 3 D IP 66 T O max. 1) Certificates 1) see selection table Gas explosion protection Zone 2: SNCH 03 ATEX 3515 Dust explosion protection Zone 21: SNCH 03 ATEX 3514 Zone 22: SNCH 03 ATEX 3515 Conformity Rated voltage Rated current CE 0102 to 94/9 EG 220 V V, AC, + 6 %, 50 Hz, others available on request Dimensions 6521/3. Halogen lamps * * Metal-halide lamps * HIT * High-pressurelampe sodium lamps * * Size 6521/31 Size 6521/32 Size 6521/33 Power I N Power I N Power I N 100 W 150 W 0.44 A 0.65 A 1.1 A 70 W 150 W 500 W 2.17 A 500 W 1000 W 2.17 A 4.35 A 400 W 1.0 A 1.8 A 70 W 3.0 A 150 W 3.0 A 4.2 A 400 W 600 W 0.98 A 1.8 A 3.0 A 3.0 A 4.45 A 6.2 A Power factor cos p High-pressure lamps, compensated, cos p > 0.9 Protection class Connection Material Housing Front cover Gaskets Reflector Housing lock Installation orientation Mounting I (with internal PE connection) L1 + N + PE, for 2.5 mm 2 single-wire and fine-strand flexible Cage clamp terminals, 2 clamping points Sheet steel, stainless steel Safety glass; temperature change resistant Silicone Aluminium, anodized Hexagonal socket screws, M 5, stainless steel Hinged enclosure cover Horizontal lamp axis Degree of protection IP 66 and EN Ambient temperature 20 C C / 50 C U-shaped mounting bracket made of stainless steel; pivots around floodlight axis (infinitely adjustable) 7/3
4 Floodlight 7 Technical Data Cable entries made of metal Standard: 1x M 25 x 1.5 cable gland, clamping area d 10 mm mm 1x M 25 x 1.5 stopping plug 1x M 25 x 1.5 cable entry (with blind plugs - as test holes) Special: 1x M 20 x 1.5 cable gland, clamping area d 6 mm mm 1x M 20 x 1.5 stopping plug 1x M 20 x 1.5 cable entry (with blind plugs - as test holes) Other: specific customer orders possible Dimension drawings (all dimensions in mm) - subject to alterations 09721E E00 Size 1, 6521/31 1) Size 2, 6521/32 1) 1) Shown with baffle sreen and light visor, both parts are accessories and are not included in the standard scope of delivery Size 3, 6521/33 1) 09723E00 7/4
5 7 Floodlight Dimension drawings (all dimensions in mm) - subject to alterations D d E E00 Mounting base (rotatable) Pole mounting attachment Accessories Accessories and Spare Parts Designation Illustration Description Ordering code Weight Power Voltage Lighting current kg 150 W E V 2500 Im 230 W E V 4200 Im 500 W E V Im 1000 W E V Im , , , ,152 Metal-halide lamps HIT / HIE Power Voltage Lighting current 70 W E V 6500 Im , W E V 8000 Im , E W E V Im , W E V Im ,206 E V Im , W E V Im ,235 High-pressure sodium lamps Power Voltage Lighting current 70 W E V 6000 Im , W E V Im ,170 E V Im , W E V Im , W E V lm ,220 7/5
6 Floodlight 7 Accessories and Spare Parts Designation Illustration Description Ordering code Weight Light visor Baffle screen Mounting base (rotatable) Pole mounting attachment Window Cable gland Stopping plug 09785E E E E E E E00 Stainless steel for Attaches to front cover for 6521/ ,450 for 6521/ ,900 for 6521/ ,200 Stainless steel for Attaches to front cover for 6521/ ,940 for 6521/ ,100 for 6521/ ,900 Stainless steel for all sizes ,235 For installation on end of pole (stainless steel) d 60 mm ,430 d 76 mm ,260 d 89 mm ,180 (replacement glass) for 6521/ ,530 for 6521/ ,100 for 6521/ ,600 Brass, nickel-plated with O-ring M ,010 M ,010 Brass, nickel-plated with O-ring M ,010 M ,010 kg We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustrations cannot be considered binding. 7/6
Pendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationPendant Light Fittings Series 6050
> Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A
More informationEx td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread
I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem
More informationI Ex-protected connectors exlink I
Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity
More informationEXPlora. Introduction
Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant
More informationEXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder
EXEL - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22 Reinforced polyester resin body G13 bi-pin lamp holder Internal emergency batteries
More information9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218
9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,
More information3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications
. Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire
More informationEXLUX ECOLUX 6480 Series
EXLUX ECOLUX 6480 Series L I G H T I N G 6000 6008 6400 6408 6600 6608 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent
More informationSICOMPACT A2 MIDI. Product family datasheet. Asymmetrical floodlights for outdoor use. Areas of application _ Sport arenas _ High-security areas
SICOMPACT A2 MIDI Asymmetrical floodlights for outdoor use Areas of application _ Sport arenas _ High-security areas Product benefits _ No light spill _ Variable installation possibilities _ Greater safety
More informationEXLUX ECOLUX C-LUX 6480 Series
EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent
More informationJUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat
More informationLIGHTING SOLUTIONS. The bright side of the ship
LIGHTING SOLUTIONS The bright side of the ship Philosophy Three things you should know about us 1Established by experienced specialists in 1995, Lightpartner has developed into the leading provider of
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationCircuit-Breakers for Motor Protection Series 8523/8
> Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting
More informationLighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof
ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof 2 x 58 W Compliance Data: ATEX IECEx: ATEX IECEx CE Ex d IIB Ex d IIC
More informationEX-PROTECTED PORTABLE POWER SUPPLY UNITS
EX-PROTECTED PORTABLE POWER SUPPLY UNTS 125 A for Zone 1 Special requirements apply for power distributions for the use and operation of portable equipment in hazardous areas in Zones 1, 2, 21 and 22.
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationJUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell
More informationSERIES 400 SERIES 620
x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationNessie Coils for VDH and VDHT valves
Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationExplosion Proof Audible Signal db(a) Series YA60
> Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationTFRH Hygienic RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy
More informationCoils for solenoid valves
MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.
More informationOptiVision Tame your floodlighting
OptiVision Tame your floodlighting Putting people s rights in a new light People near floodlight installations have a right to peace and tranquillity. environmentally friendly floodlighting has become
More informationOperating instructions
108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.
More informationLED HIGHBAY I-VALO XENRE
LED HIGHBAY I-VALO XENRE I-VALO XENRE Light source Ta class Input power Lumen output Colour temperature MacAdam value Efficacy of the luminaire Ingress protection Light distributions Cover material Body
More informationXML LED X M L L E D. Explosionproof Linear LED Lighting
LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending)
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationSITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43
Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.
More informationLt DELTA USA, Inc
Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6
More informationHorn loudspeaker, Ex proof, short/long flare
Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure
More informationIllustrated Feature. Options
Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups
More informationFilters for Power Lines (Low Leakage Current)
Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures
More informationExplosion Proof Audible Signal db(a) Series YA60
> Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable
More informationArenaVision MVF404 exceptional optical efficiency
Lighting ArenaVision MVF404 exceptional optical efficiency ArenaVision MVF404 The ArenaVision MVF404 floodlight designed for outdoor sports stadiums dramatically increases the theatrical and emotional
More informationArenaVision MVF404 exceptional optical efficiency
Lighting exceptional optical efficiency The floodlight designed for outdoor sports stadiums dramatically increases the theatrical and emotional impact of sports for TV audiences and spectators, while allowing
More informationOptical Signal Devices. Free-standing Beacons
Free-standing Beacons Overview Free-standing Permanent Beacons Flashing Beacons 200/203 201/204 (LED) 209 209 (LED) 210/213 211/214 (LED) 219 219 (LED) 202 Flashing 205 Flashing 209 Flashing Beacon 212
More informationRevision 1.0 Parts List Minor
Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded view...
More informationSensor technologies Proximity sensors Series ST4. Brochure
Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with
More informationwww.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~
More information19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43
19" TiRAX cabinet system from page 3 19" NETcell cabinet system from page 31 Open 19" racks from page 43 all-mounting/stand-alone distribution systems from page 53 all-mounting enclosure systems from page
More informationRevision 1.0 Parts List Salvador 1~, 3~
Revision.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded
More informationDewatering. Series description Wilo-Drain STS 65. Submersible sewage pump
Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring
More informationCAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry
CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001
More informationUSER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.
d.o.o. tel. 049 900, fax 049 46 450 email: tepex@tepex.hr www.tepex.hr USER MANUAL FOR EPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE. Doc. No: TEPEx.RS.058 Ver : 0 Date: 11.014. SADRŽAJ 1. Manufacturer
More informationLinear flow control with actuator IFC
Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20
More informationLIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances
Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups
More information3 Cleaning. 4 Technical data
EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution
More informationM A R I N E B R I G H T S O L U T I O N S
M A R I N E B R I G H T S O L U T I O N S L I G H T I N G F I X T U R E S Sea Bright has become a well-known and sought brand for the design and manufacture of lighting fixtures. The company is oriented
More information2.9 Sigma/ 2 Plunger Metering Pumps
.9 Sigma/ Plunger Metering Pumps.9Sigma/ Plunger Metering Pumps.9.1 Sigma Plunger Metering Pumps The Sigma/ motor plunger metering pump has a high-strength inner metal housing for those component parts
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationLinear flow controls VFC Linear flow controls with actuator IFC
Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or
More informationFor Sales & Information, Call Toll Free: (888)
PCR Outline Dimensions 2.75" (69.8 mm) 0.44" (11 mm) 0.25" (6.3 mm) (-) (+) 15.8" (401 mm) 9.3" (236 mm) Nameplate 1.25" (31.8 mm) 3.0" (76 mm) 7.40" (188 mm) 12.63" (321 mm) R 0.219" (R 5.56 mm) Serial
More informationS020 fluorescent tube luminary
S020 fluorescent tube luminary DESCRIPTION: Fluorescent lamps S020 are suitable above all for uniform lighting of bigger areas. Lamps from the range S020 are manufactured from extruded aluminium profile
More informationGrounding-type plugs and sockets K Product information
Product information Plugs and sockets for harsh conditions. SCHUO by MENNEES with the hammer symbol. Acc. to VDE 0105 part 115. Made of high-grade AMAPLAST. Acc. to VDE 0620 for harsh conditions. Application
More informationFigure 1: Device components
Order No. : 2860 10 Order No. : 2830 10 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe
More informationRevision 3.0 Parts List Salvador 1~, 3~
Revision 3.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data
More informationENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:
ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental
More informationRevision 2.0 Parts List Minor
Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3 Exploded
More informationChapter 1 Facade and path luminaires
Chapter 1 Facade and path luminaires 1 Facade and path luminaires Overview CL Ceiling 10 MINI Page 1.8 CL Ceiling 10 MIDI Page 1.8 CL Spotlight 10 LED Page 1.24 CL Spotlight 10 Page 1.28 6m CL Spotlight
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationThe Tego Ceiling System
The Tego Ceiling System T +32 (0)67 89 49 29 page 1 welcome@transelec-group.be Ceiling System The Ceiling System is a multifunctional ceiling with numerous qualities. The ceiling is constructed by channels
More informationTECHNICAL INFORMATION
OCTALUMINA 120: PARTS LIST AND TECHNICAL INFORMATION HIGH POWER LEDS INNER CORNER LABELED FRAME MOUNTED POWER SUPPLY UNIT EASY PLUG-IN CONNECTION BRACING TECHNIQUE CABLE OUTLET AT THE BOTTOM SYSTEM PACKAGING
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full
More informationLiner Quattro AC XB RGBW
Date: Quantity: Company: Project: Liner Quattro AC XB RGBW The Liner Quattro AC XB RGBW is an AC line powered, high brightness luminaire. The luminaire is controllable via DMX512 with auto-addressing for
More informationMax. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm
21.610/1 RAK: Universal thermostat How energy efficiency is improved Demand-led controlling, monitoring and limiting, without auxiliary energy. Areas of application For controlling and monitoring the temperature
More informationwith additional normally-open signalling contact l With integrated AS interface Safety at Work.
Safety Hinge Switch SHS3 In addition to the plug connection version, an SHS with fixed cable connection at the rear is also available Right and left hinged systems possible for optimum cable routing Mounting
More informationSafety dialogue solutions
Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,
More informationPROPORTIONAL VALVES Sentronic plus
04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital
More informationOkta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz
Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Similar Image Dimensions Technical Data Ambient temperature 5-40 C Cooling method, standard
More informationPanel-Mounted Thermostat
Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief
More informationDMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.
DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output
More informationLinealux L5 Linear Facade
The Linealux L5 is a high power architectural grade luminaire that combines technology and performance in a stylish linear form factor. Available in white, colour changing and tunable white light engines,
More informationKVT Split cable glands
KVT Split cable glands Description Type Order Inserts KT Thread PU No. small large Thread length KVT is a circular split frame for quick and easy installation of cables or complete cable harnesses. Polyamide
More informationMAXX BOX. MX102/202 Series. MAXX Box
MX102/202 Series MAXX Box MAXX BOX 1 C O N T E N T S SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 Ordering Information... 4 Specifications... 5 Environmental... 5 Electrical... 5 Physical...
More informationTYPE APPROVAL CERTIFICATE
DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-12360 This is to certify that the Cable Gland with type designation(s) ADE & RE; AD; FF; MM; SP; ET; LN. Manufactured by COOPER CAPRI SAS
More informationENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:
ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationWater temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %
Main Applications Disinfection of Primary, secondary and tertiary treated wastewater effluents for discharge Wastewater for reuse (e.g. for irrigation of parks, agriculture) Process water for industrial
More informationRevision 2.0 Parts List Minette 1~, 3~
Revision.0 www.grindex.com Parts List 80.7 Minette ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3
More information-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.
Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.6 N LE 3 NEBV Connecting cables for valves Connection technology on left, field device side B2 Socket type B to industry standard,
More informationLevel Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB
Level Switch LS Ex KS Ex RS Ex Manual Level Switch Ex Manual version 3.0 March 2013 2 1. Table of contents 1. Table of contents...3 2. Manufacturer information...4 Manufacturer Declaration of Conformity...4
More informationMechanical flow switch for On/Off control
Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More informationSAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations
LED Class I, Division 2, Groups A, B, C, & D Class II, Divisions 1 & 2, Groups E, F & G Class III UL 1598A Marine Outside Type UL 1598 Wet Locations UL 844 Hazardous Locations UL 8750 LED Safety Tested
More informationUp to 85% higher Service Life due to efficient sealing method.
Robot Accessories Feeding through Up to 85% higher Service Life due to efficient sealing method. 346 Robot Accessories Feeding through Feeding through DDF 2 Rotary Feed-through Series Size Page DDF 2 348
More information