Mortara X-Scribe Tango+ Interface Notes

Similar documents
Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Philips StressVue Tango M2 Interface Notes

Pulse Biomedical QRS-Card Tango M2 Interface Notes

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Cardioline Cube Stress Tango M2 Interface Notes

Burdick Quest Tango M2 Interface Notes

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

Schiller AT-10 plus Tango M2 Interface Notes

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

GWL/ Power Group Technology Solutions Stay Powered for the Future

Quick Start Guide Building and Scheduling a Show

RF Solution for LED Display Screen

YAMAHA 03D SERIAL AUDIO MIXER

Camera Setup Instructions

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

1 Synchronising Xsens with the Delsys Trigno EMG System

Audio Design Associates (ADA)

Honeywell HomMed Wireless Scale Quick Reference Guide

EEG A1452 SCTE-104 Inserter Frame Card

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

YAMAHA 03D SERIAL AUDIO MIXER

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

Interface sheet - Edan ST-1212 Stress - CPET ergometer

Data Acquisition Instructions

Auxiliary states devices

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

Interface sheet - Nihon Kohden 1550K - CPET Treadmill

Absolute volume control is also possible with SP Controls option Audio Follow Video Preamplifer.

SXGA096 DESIGN REFERENCE BOARD

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

2 Connect your video source

User Manual for ICP DAS WISE Monitoring IoT Kit -Microsoft Azure IoT Starter Kit-

DX-10 tm Digital Interface User s Guide

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

Cablecast Server. Setup Guide. c Tightrope Media Systems For Cablecast version Build 74

Cisco/Scientific Atlanta 330 & 430. HD Television. Sun City & Hilton Head Island. Q u i c k TELEPHONE TELEVISION INTERNET WIRELESS SECURITY

Interface sheet - Korr Cardio Coach Monitor - CPET Ergometer

R4 AIS Class B Transponder

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

How-to Note: Quickstart: ITM9000 [This note applies to ITM9000 (handheld tester)] Contents. Overview. Materials Included

SignalTap: An In-System Logic Analyzer

Multi RF Deck / Multi Control Head

Integration of the Zetasizer µv and OmniFACE into an SEC system

VNS2200 Amplifier & Controller Installation Guide

R Series Quick Reference Guide

2 Connect your video source

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

Modbus for SKF IMx and Analyst

RADIO FREQUENCY SYSTEMS

Operating Instructions

Revision Protocol Date Author Company Description January Paul DOS REMEDIO S. Imagine Communications

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

Guide For Setting Up Your Fortec Lifetime Ultra Receiver

Installation Note. Agilent 89441A Option AYC Installation Kit

Weschler AMT Software for the Enhanced Version Transformer Advantage

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

medlab One Channel ECG OEM Module EG 01000

Amino. Digital Television. Sun City & Hilton Head Island

DXP A0808 Quick Start

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

Using LightSpace CMS for User Created Calibration LUTs

CI-218 / CI-303 / CI430

Revision Protocol Date Author Company Description 1.1 May 14, Seth LOUTH Revised for formatting

P-2 Installing the monitor (continued) Carry out as necessary

Configuration Vestas VMP3500

CHAPTER 3 EXPERIMENTAL SETUP

PLASMA MONITOR (PT20 UVVis) USER GUIDE

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Table of Contents. Versa TILE & Versa DRIVE D2 Quick Start Manual

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

Video Server SED-2100R/S. Quick Installation Guide

APPLICATION NOTE 4254 PRBS Mode Setup for the MAX9257/MAX9258 Evaluation Kit

ivw-ud322 / ivw-ud322f

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work?

Quick Start Guide for Cisco Digital Media Encoder 2200

COLOR TFT LCD MONITOR. Manual

F24X DSK Setup and Tutorial

TriLIN Program Utility TPU_ TriLIN Programming Manual

VNS2210 Amplifier & Controller Installation Guide

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

2 Connect your video source

Quick Setup 1 Unpack the projector

C Module Description

Manual 4.0. VIPdigital Manual 4.0 Yellowtec 2004 Rev Page 1

InfiniTV 4 Installation Instructions

Using SignalTap II in the Quartus II Software

Professional Media Server Quick Start Guide

Quick Setup Guide. DCX-500i / DCX-1000i / DCX-1500i Projectors with WC-Pro Scaler. Preliminary

Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

Globalmediapro SMR-650

ZAXCOM ARRIA DIGITAL MIXER

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Transcription:

Mortara X-Scribe Tango+ Interface Notes To setup Tango+ with the X-Scribe stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate with the X-Scribe. This cable enables the X-Scribe to prompt Tango+ when it needs a BP measurement, and allows the Tango+ BP reading to be transferred to the X-Scribe display and reports. o SunTech Part Number = 91-0013-00 o Connection Ends: X-Scribe Connection 9 pin female Tango+ Connection 9 pin female ECG Trigger Cable provides the ECG signal from the X-Scribe to the Tango+. o SunTech Part Number = 91-0011-00 o Connection Ends: X-Scribe Connection BNC male Tango+ Connection BNC male Mortara X-Scribe, Tango+ Interface Notes Page 1 of 5

Tango+ Monitor RS-232 Connection Part # 91-0013-00 ECG Trigger Connection Part # 91-0011-00 SunTech Tango+ BP Monitor TTL (BNC) Cable from M12RF2500 Unit Power Cord Mortara M12RF Microphone RS232 Data Cable (Com2) BP Cuff Mortara X-Scribe Mortara X-Scribe, Tango+ Interface Notes Page 2 of 5

USB Interface M12RF2500 ECG Trigger TTL 2. Connect the RS-232 Cable From: To: the RS-232 connection on the rear panel of the Tango+. the COM 2 port on the back of the X-Scribe. If a second serial port is not available, a PC board to provide this 2 nd serial port may be required (contact Mortara for details). 3. Connect the ECG Trigger Cable From: To: the BNC External ECG connection on the rear panel of the Tango+. the TTL output connection on the back of the Mortara M12RF2500 module. 4. Tango+ Monitor Setup a. When the operating screen is displayed, press the SELECT button 2 times. This will bring up the MAIN MENU screen. b. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT c. Using the UP or DOWN arrows, highlight STRESS SYSTEM and press the SELECT d. Using the UP or DOWN arrows, scroll through the list until X-Scribe II is highlighted and press the SELECT button to confirm the choice. e. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. 5. X-Scribe System Setup a. Highlight and click on Settings from the X-Scribe main menu. The Configuration Settings window will be displayed. b. In the Exercise Options Tab, click on the NIBP drop down menu. Mortara X-Scribe, Tango+ Interface Notes Page 3 of 5

c. Select SunTech Tango. d. Highlight and click on the Save Profile e. Select Yes when prompted by This profile will be overwritten Do you want to continue? f. Repeat steps b through e for each Profile that you wish to utilize the SunTech Tango+ automatic BP monitor. Note: The X-Scribe Blood pressure entry control or Exercise and Recovery protocols will now automatically initiate and acquire BP readings from the Tango BP Monitor. Mortara Instrument, Inc. Technical Support - (888) MORTARA FAQs for Tango+ Q. The Tango+ displays a status message. What does it mean and what do I do? A. See the Quick Set-Up guide (that is attached to your Tango+) or the Troubleshooting section in your User s Guide for details on the Status Message and solution. Q. The Tango+ monitor returns results of 0/0 after blood pressure measurements. What do I need to do to get a BP reading? A. There are certain noisy conditions where the Tango+ cannot accurately measure BP. When the Tango+ encounters these situations, it returns a reading of 0/0. Placement of the microphone attached to the cuff is critical for reliable operation of the Tango+. Follow the instructions in the Cuff Tutorial (located on the SunTech Medical website under Products Tango+) for correct microphone placement. Follow steps 1 and 2 in Conducting the Stress Test in the User's Guide to provide the best conditions to obtain a measurement. Q. Can I use a heart rate or blood pressure simulator to test whether the Tango+ is working correctly with my stress system? A. You cannot use a heart rate or blood pressure simulator to test whether the Tango+ is working with your stress system. The Tango+ monitor requires that the ECG signal and the Korotkoff sounds, collected by the microphone in the cuff, originate from the same source, meaning the patient. Q. I cannot clearly see the Tango+ display. How do I fix this? A. If you cannot clearly read Tango+, you can adjust the contrast of the display by following these steps: 1. When the operating screen is displayed, press the SELECT button 2 times. This will bring up the MAIN MENU screen. 2. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT 3. Using the UP or DOWN arrows, highlight CONTRAST and press the SELECT 4. Using the UP or DOWN arrows, modify the contrast of the screen. When you are finished, and press the SELECT button to confirm the choice. 5. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. Mortara X-Scribe, Tango+ Interface Notes Page 4 of 5

Q. My Tango+ displays a message, Please VERIFY CALIBRATION or Equipment Maintenance and Calibration Required. What do I do? A. Verification of Pressure Calibration Equipment Required: 1. Calibrated electronic manometer or equivalent. 2. 500mL volume or the Orbit-K Adult Plus cuff wrapped around something that will not break or crush (no glass). 3. Hand Inflation Bulb with bleed valve. 4. Tubing, Tee pieces, and miscellaneous connectors or you can order the T-Tube Kit (SunTech Part # 98-0030-00). Procedure: 5. When the operating screen is displayed, press the SELECT button 2 times. This will bring up the MAIN MENU screen. 6. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT 7. Using the UP or DOWN arrows, highlight VERIFY CALIBRATION and press the SELECT The monitor will close its bleed valves and will display on its screen the pressure applied to the patient hose connector. 8. Verify the Tango+ calibration by manually inflating and checking the manometer against the pressure reading on the Tango+ display. 9. Once the calibration has been completed, use the UP or DOWN arrows to select EXIT twice and return to the operating screen. Mortara X-Scribe, Tango+ Interface Notes Page 5 of 5