Recirculating. Chiller. Sustainable cooling

Similar documents
Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

DM 50 / DM / 2- component dosing and mixing system. engineering

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Model KBF 720 Constant climate chambers with large temperature / humidity range

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

HICUBE. The modular pumping stations for all applications in high and ultra-high vacuum

User Guide Stand-Alone Metering for OptiPlant

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

Model KT 170 Cooling incubators with thermoelectric cooling

Gordian. Multifunctional Power Distributor / Conditioner. v1.3

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

R&S ZN-Z85 Switch Matrix Specifications

Thermo Scientific Merlin Recirculating Chillers

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

Magnetic Stirrers Magnetic Stirr

R&S ZN-Z154 Calibration Unit Specifications

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Model KBF P 240 Humidity test chambers with ICH-compliant light source

MAXIMUM PRODUCTIVITY DUE TO SHORTEST CONVERSION TIMES

Model KBF 1020 Constant climate chambers with large temperature / humidity range

ih Series Drypumps (505) idealvac.com idealvac.com

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Air cooled Outdoor installation R-410A Hermetic Scroll Ice protection system FREE-COOLING HydroPack ECOBreeze Electronic expansion valve

Model KBF 115 Constant climate chambers with large temperature / humidity range

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Agilent High Capacity RV Pumps & Roots Pumping Systems

Centrifuge 5418/5418 R

Wall-/Pipe-Mount Level Indicator

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Air cooled water chillers with screw compressors From 134 kw to kw

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage

Users Manual. Stroboscope. September 2014

Features. Specifications. Finish. Notes

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S HF907DC SHF Downconverter Specifications

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

istep STEPPER MOTOR PUMP

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Thermo Scientific Polar Series Cooling/Heating Recirculating Chillers

Okta 1000, Roots pump without motor

CHEETAH-X Compact Picosecond Laser. Customized systems with SESAM technology*

UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

S N A C K S D R I N K S. for the sale of confectionery/snacks and bottled and canned drinks RANGE

TUC: Universal thermostat

DM 402/ / multi-component low pressure dosing and mixing system. engineering

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

DM 402/ / multi-component low pressure dosing and mixing system. engineering

DISTRIBUTION AMPLIFIER

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

istep STEPPER MOTOR PUMP

Model KT 115 Cooling incubators with thermoelectric cooling

Flow Switch. Flow Switch

SM-10 SAT Level Meter User s Manual

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

3B SCIENTIFIC PHYSICS

OPERATOR S MANUAL TRUCHECK & TRUCHECK PLUS. Part Number Issue 1 Original Instructions (English)

R&S RT-Zxx High-Voltage and Current Probes Specifications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

The extremely compact laser head is approximately 480 mm long and can

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

KEMPPI K5 WELDING EQUIPMENT. Kempact Pulse 3000 QUALITY, SPEED AND PRODUCTIVITY

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

David Mrnak, International Sales Department, eyevis GmbH

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

DMX LED light effect with 4 lenses

Model KT 53 Cooling incubators with thermoelectric cooling

R&S RT-Zxx Standard Probes Specifications

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

CTC Series. Compact Temperature Calibrator

Oil/air cooler. Table of contents. Features. Applications. RE 50112/05.13 Replaces: Type KOL and KOLP

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Engineered to meet your needs T he oldest name in stud welding,

OLED THE PERFECT HIGH-RESOLUTION DISPLAY

The extremely compact laser head is approximately 480 mm long and can

All the energy of your home, in an App!

Capacitance Limit Detection nivotester FTC 420/421/422

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

R&S RSC Step Attenuator Where precise signal levels count

E15X-SUB Manual (1.2 EN)

Intelligent solutions for Onshore Power Supply

Series description: Wilo-Drain VC

YVAA Air-cooled VSD screw chiller

Electrical Specifications

UNIGAS Hand-held combustion gas analyzer with 3 sensors

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

DB-x20 Digital Billboard

Transcription:

Recirculating Chiller Sustainable cooling en

Chillers controlled by the Evaporation system The new generation of recirculating chillers is now connected to the evaporation system and can be controlled by the vacuum controller. The benefits of this integrated system include: up to 75% less energy consumption reduction of heat emission in the lab easy handling optimized distillation capacity process safety due to communication of all connected instruments Buchi enters new territory by introducing the fully integrated chiller line. Experience a distillation process in which all parameters are integrated into one complete evaporation solution. What does this mean in detail: One central operation panel for vacuum and cooling. Avoid common misadjustment. The set and actual cooling temperatures, as well as the working pressure, are displayed on the vacuum controller. Clear display of all relevant process parameters. At the end of the distillation the controller switches of the Rotavapor and also the recirculating chiller. Save energy and reduce the heat emission. The solvent library on the controller can now, based on the heating bath temperature and cooling temperature, calculate the optimal pressure for a distillation. Maximal distillation capacity by minimal vapor emission can be calculated automatically. The cooling temperature is always observed. Cooling temperatures deviating outside safe operating parameters signal an audible warning. Increase safety for users and environment.

Different power rating for different requirements Whether you are using rotary evaporators, parallel evaporators, Soxhlet-Extraction or nitrogen determination, Buchi supplies multiple chillers which covers the complete application range. F-100 Cost effective, small recirculating chiller that fulfills the basic chilling requirements. The perfect replacement of tap water chilling with small distillation instruments. Cooling range: fixed cooling temperature at 10 C one Rotavapor one Multivapor one Soxhlet-Extraction unit one Kjeldahl system F-105 This chiller is based on an F-100. The additional integrated temperature control enables the user adjustment of the cooling temperature down to +5 C as well as remote cooling control through the vacuum controller. Working range: + 5 C + 25 C one Rotavapor at 10 C one Multivapor at 10 C one Soxhlet-Extraction unit one Kjeldahl system F-108 Increased cooling capacity of 800 W at +15 C, the F-108 is a powerful alternative to the F-100 and F-105. This chiller offers a lower usable cooling temperature of 0 C further expanding the application range. Working range: 0 C + 25 C two Rotavapor at 10 C one Rotavapor at 0 C two Multivapor at 10 C one Syncore Platform at 10 C one Soxhlet-Extraction unit at 10 C F-114 Choose the F-114 when very low temperatures are requirement for one or multiple units. Cool temperatures of 10 C and achieve a very powerful cooling capacity of 1400 W at +15 C. Working range: 10 C + 25 C two Rotavapor at 0 C one Rotavapor at 10 C one Syncore Platform at 0 C

Choosing intelligently F-100 F-105 F-108 F-114 F-125 400 W/10 C 500 W/15 C 800 W/15 C 1400 W/15 C 2500 W/15 C Rotavapor 1l R-210/215 Rotavapor 1l 2 x R-210/215* Rotavapor 20l R-220 SE Syncore Extraction B-811/812/816 Auto Kjeldahl K-370 Working range 10 C to 0 C 0 C to 10 C 10 C to 20 C F-114 F-108 F-114 F-125 F-114 F-108 F-100/105 F-108 F-108 F-100/105 F-100/105 * The chiller can only be controlled by one Vacuum Controller. In a setup with two or more Vacuum Controllers, the chiller has to be operated via the control panel of the chiller. Using this graph, determine the optimal system depending on the required cooling capacity. Cooling capacity (W) 3000 2500 2000 1500 1000 500 0 + 15 + 10 ➋ ➊ + 5 0 5 10 Temperature ( C) F-125 F-114 F-108 F-100/105 2 x R-210, 800 W Example: You are looking for a chiller to cool two rotary evaporators to 5 C ➊. Together these two rotary evaporators produce a heat out of approximately 800 W ➋. The recirculating chiller F-108 does not have sufficient cooling capacity at 5 C. You should then choose the next chiller in the range, the F-114. This chiller will provide approx. 1200 W cooling capacity at 5 C therefore compensating for the 800 W output by the two rotary evaporators. Common system Chillers that are not fully integrated with the entire evaporation system are environmentally wasteful and cost you money every day. They do not shut off automatically between distillations. This wastes a lot of energy and generates heat in the lab. Buchi system + Environmentally responsible and save you money every day. + Fully integrated with our evaporators and vacuum controllers. + Switch to stand-by mode between distillations. + Conserves energy. This reduces heat emissions to an absolute minimum.

The new Recirculating Chiller F-125 space saving system cooling capacity of 2500 W at 15 C robust and stable construction mobile Integrated vacuum pump Improved system functions Regulate chiller temperature via Rotavapor R-220 SE Adjustable range limitations keep cooling medium within close monitoring parameters A warning message is displayed if cooling medium is out of range The chiller temperature can be controlled separately via a solvent library Automatic switch-off after finishing the process Accommodates the required vacuum source V-710 Pump head windows allow for visible inspection of condensation Display and control panel on chiller Secondary condenser on the vacuum pump Second monitor to display set and actual temperature Independent usage of chiller without vacuum controller is possible Moving the system Built-in power plug Secondary condenser for best environmental protection Placed in front of the unit for easy handling Additional plug for power supply of the vacuum pump Lockable wheels for easy movement and secure breaking

Order information F-100 F-105 F-108 F-114 F-125 115 V 11056461 230 V 11056460 115 V 11056463 230 V 11056462 115 V 11056465 230 V 11056464 115 V 11056467 230 V 11056466 115 V not available 230 V 11056468 Distribution piece to connect 2 instruments on one distillation chiller (9.5 mm hose connection) Order no. 037742 Technical data BÜCHI Labortechnik AG CH 9230 Flawil 1 T +41 71 394 63 63 F +41 71 394 65 65 buchi@buchi.com www.buchi.com BÜCHI Labortechnik GmbH D 45127 Essen Freecall 0800 414 0 414 T +49 201 747 490 F +49 201 237 082 deutschland@buchi.com www.buechigmbh.de BUCHI Sarl F 94656 Rungis Cedex T +33 1 56 70 62 50 F +33 1 46 86 00 31 france@buchi.com www.buchi.fr F-100 F-105 F-108 F-114 F-125 Power consumption (max.) 850 W 850 W 1350 W 1850 W 2850 W Supply voltage BUCHI UK Ltd. GB Oldham OL9 9QL T +44 161 633 1000 F +44 161 633 1007 uk@buchi.com www.buchi.co.uk BÜCHI Labortechnik GmbH NL 3342 GT Hendrik-Ido-Ambacht T +31 78 684 94 29 F +31 78 684 94 30 netherlands@buchi.com www.buchi.nl BÜCHI Italia s.r.l. I 20090 Assago (MI) T +39 02 824 50 11 F +39 02 57 51 28 55 italia@buchi.com www.buchi.it BUCHI Hong Kong Ltd. HK Central T +852 2389 2772 F +852 2389 2774 china@buchi.com www.buchi.com.cn BUCHI Shanghai RC 500052 Shanghai T +86 21 6280 3366 F +86 21 5230 8821 china@buchi.com www.buchi.com.cn BUCHI (Thailand) Ltd. T Bangkok 10600 T +66 2 862 08 51 F +66 2 862 08 54 bacc@buchi.com www.buchi.com Nihon BUCHI K.K. J Tokyo 110-0008 T +81 3 3821 4777 F +81 3 3821 4555 nihon@buchi.com www.nihon-buchi.jp BUCHI India Private Ltd. IND Mumbai 400 055 T +91 22 667 18983 / 84 / 85 F +91 22 667 18986 india@buchi.com www.buchi.in Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Display no display digital, resolution 0.1 K digital, resolution 0.1 K digital, resolution 0.1 K digital, resolution 0.1 K Overvoltage category II II II II II Dimensions (W x H x D) 280 x 400 x 500 mm 280 x 400 x 500 mm 400 x 500 x 580 mm 400 x 500 x 660 mm 990 x 540 x 650 mm Weight 29 kg 29 kg 40 kg 42 kg 100 kg Cooling at 15 C 500 W 500 W 800 W 1400 W 2500 W Temperature range fix +10 C 10 C... + 25 C 10 C... + 25 C 10 C... + 25 C 10 C... + 25 C Working range fix +10 C +5 C... + 25 C 0 C... + 25 C 10 C... + 25 C +5 C... + 25 C Refrigerant R134 R134 R134 R134 R134 Hysteresis ± 2 K ± 1 K ± 1 K ± 1 K ± 1 K Tank volume 3 l 3 l 5 l 8 l 11 l Hose connection 8 mm 8 mm 9.5 mm 13.5 mm 13.5 mm Pump capacity 0.6 bar 0.6 bar 0.6 bar 1 bar 1 bar Flow rate 2.5 l/min 2.5 l/min 3 l/min 11 l/min 11 l/min BUCHI Canada Ltd. CDN Thornhill, Ontario L4J 6Z 2 T +1 416 277 7407 F +1 905 764 5139 canada@buchi.com www.mybuchi.com BUCHI Corporation USA New Castle, Delaware 19720 Toll Free: +1 877 692 8244 T +1 302 652 3000 F +1 302 652 8777 us-sales@buchi.com www.mybuchi.com 11592294 en 1010 / Technical data are subject to change without notice/ Quality Systems ISO 9001 The English version is the original language version and serves as basis for all translations into other languages. We are represented by more than 100 distribution partners worldwide. Find your local representative at www.buchi.com