EA350. Generator Automatic Voltage Regulator Operation Manual

Similar documents
Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

ADVR-053. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

EVC300i. Generator Automatic Voltage Regulator Operation Manual

EVC600i. Generator Automatic Voltage Regulator Operation Manual

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

EG4015. Digital Generator Governor Controller User Manual

ADVR-08. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

AF-300 E11 Adjustable Frequency Drive

REGO Start&Go USER MANUAL

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

MAP110 AC-DC Series Data Sheet

Build A Video Switcher

BUF2000 Video Buffer Amplifier with Gamma

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Level Measurement silometer FMC 420, FMC 423

Flat-Bed Module Recorders

Telemetry Receiver Installation Guide

N3ZI Digital Dial Manual For kit with Backlit LCD Rev 4.00 Jan 2013 PCB

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

multi-function meters

02/11/2015

OTM-3550-SW FREQUENCY AGILE F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Low Noise Solid State Phono Preamplifier User's Guide and Operating Information

TOSHIBA Industrial Magnetron E3328

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

DA VGA Line Receiver User s Guide

SQM40/41 Actuators for air and gas dampers

PAM-1840 Preamplifier Operation Manual

Set Point Controller OC557. Operator s Manual

Westrex RA1713B Auxiliary Record Electronics

N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012

J R Sky, Inc. tel: fax:

Gamma instabus. Technical product information

User Guide. Centrex Recording Interface

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Certificate of Calibration

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

Operating instructions Electronic preset counter Type series 717

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

1 Power Protection and Conditioning

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Indoor Linear 80W Driver SI-C215280N2KR

COHERENCE ONE PREAMPLIFIER

Catalogue Ignitors and power switches for HID

APPLICATIONS. Automatic warehouse. Trasportation lines

Revision 1.2d

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

Reproduce Amplifier Revision-D

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

Photoelectrics Through-beam Type PA18C.T..., DC

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

LED control gear Compact fixed output

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

TS2.8 Sub OWNER S MANUAL

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

Model 1421 Distribution Amplifier

DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

User s Manual TOS7200. Insulation Resistance Tester DANGER. 1. Preface Preparation Safety Precautions during Testing 19

E R A I GATE OPENERS DEPARTMENT

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

Single-Output 2000 W

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MATE3 Owner s Manual Addendum

Model Number Structure

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

MODEL PA II-R (1995-MSRP $549.00)

15 Series - Dimmer

Junior Max (JR Max ) Controller

LAUREL ELECTRONICS, INC.

DCP100 Digital Control Programmer Specifications

Quick Reference Guide

I N S T R U C T I O N D A T A

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Transcription:

Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator For General Generators Compatible with Marathon SE350* * Use for reference purpose only and not a genuine Marathon product. EN61204-3 : 2001 certified Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775 URL : http://www.kutai.com.tw

1. SPECIFICATION Power & Sensing Input Voltage 85 ~ 135 VAC / 190 ~ 240 VAC Frequency 50 / 60 Hz, Jumper selectable Output Voltage Current Resistance Max. 36 VDC @ 120 VAC input Max. 73 VDC @ 240 VAC input Continuous 4A Intermittent 7A for 10 sec (52 / 105VDC) Min. 15 ohm Max. 100 ohm Voltage Regulation < ± 1% ( with 4% engine governing ) Voltage Build-up Residual voltage at AVR terminal > 5 VAC Operating Temperature - 40 C ~ 60 C Storage Temperature - 65 C ~ 85 C External Volts Adjustment ± 5% with 1K ohm 1 watt trimmer ± 10% with 2K ohm 1 watt trimmer EMI Suppression Internal electromagnetic interference filtering Unit Power Dissipation Max. 8 watt Under Frequency Protection (Factory Setting) 60 Hz system presets knee point at 54 ~ 61 Hz 50 Hz system presets knee point at 45 ~ 51 Hz Dimensions 99.5mm L * 67mm W * 47.5mm H Weight 205g ± 2% Certification EN61204-3 : 2001 certified * Test Report on request if required Burden 250 / 500VA Max. 11.4 10.0 99.5 90.4 59.7 11.4 41.9 24.1 58.7? 4.9 16.3 67.0 47.5 UNIT : mm Figure 1 Outline and Drilling Diagram 2

Red J2 J1 Frequency Jumper Rheostat Jumper 60 50 HZ HZ 4 6 7 F- F+ 3 VOLT STAB U/F 50/60Hz, 500VA OUTPUT: 36 Vdc / 73Vdc 3.5A MODEL: INPUT: 85-135Vac / 190-240Vac VOLTAGE REGULATOR KUTAI ELECTRONIC OFF ON DIP SW FUSE 4A/250V Figure 2 Jumper and Potentiometer Control Locations 2. WIRING 2.1 Exciter Field Power Circuit Connect AVR terminal F+ to field +, connect AVR terminal F to the field. See Figure 5~6 for typical connection diagram. CAUTION! The exciter field dc resistance must be 15 ohms or greater and less than 100 ohms. If the exciter field dc resistance is less than 15 ohms and the full load field current does not exceed the maximum continuous current rating of the controller, a resistor of sufficient wattage must be added in series with the field to increase the total resistance to 15 ohms. 2.2 Sensing / Power Input Circuit Input power and sensing is achieved through terminals 3 and 4. The voltage input requirement of the is 120 to 240 VAC. See Figure 5~6. 2.3 Voltage Adjustment The screwdriver adjustable potentiometer adjusts the generator output voltage. Adjustment clockwise increases the generator output voltage. When using a remote voltage adjust rheostat, remove the jumper wire across terminals 6 and 7 and install a 2000 ohm 1/2 watt (minimum) rheostat. This will give ±10% voltage variation from the nominal. (For ±5% voltage variation use a 1000 ohm 1/2 watt rheostat). See Figure 5~6. 2.4 Stability Adjustment System stability is the ability of the generator to respond to load transients. Decreasing the stability makes the generator less sluggish and faster to respond to toad transients. If the stability of the regulator is decreased too much, the generator will tend to hunt under steady state Conditions the screwdriver adjustable potentiometer adjusts the system stability Adjustment clockwise. Increases the stability. Increasing the stability increases the response time of the generator. Conversely, decreasing the stability decreases the response time of the generator. 2.5 V/Hz Roll-Off Frequency Selection The roll off point is the frequency where the generator voltage starts to decrease. This reduces the Kilowatt load to the engine, which allows the engine to recover in speed transient condition. Use jumper to select 50 Hz or 60 Hz. The screwdriver adjustable potentiometer sets the roll-off frequency from 54~61 Hz in the 60 Hz setting or from 45~51 Hz in the 50 Hz setting. 3

The has the roll-off point preset to 58 Hz in the 60 Hz mode and 48 Hz in the 50 Hz mode. To change the roll-off point, adjust engine speed to the desired rated speed. (50 or 60 Hz). Set the voltage to the desired setting at rated speed. Adjust engine speed to the desired roll-off point. Turn the potentiometer counterclockwise until the voltage starts to drop off. Then adjust the potentiometer clockwise until the voltage returns to rated voltage. Re-adjust engine speed to rated speed. 2.6 Corner Frequency Jumper Regulator are delivered with the Corner Frequency Jumper set for 60 hertz operation. This gives a corner frequency of 55 hertz. For 50 hertz operation and a corner frequency of 45 hertz, the Corner Frequency Jumper must be moved to the 50 Hz terminal. 2.7 Voltage Adjust Rheostat Jumper Rheostat Jumper connected across terminals 6 and 7. This enables adjustment of the generator output voltage rheostat. A 1000 ohm, half-watt rheostat will provide adequate voltage adjustment range for most applications. Figure 5~6 shows the proper remote rheostat connections. The potentiometer controls are accessible through the controller front panel and are shown in Figure 2. 2.8 Voltage Adjust Rheostat Jumper 2P DIP switch on for 120Vac generator system 2P DIP switch off for 240Vac generator system 2.9 Stability Selection When excitation under voltage, it can result in insufficient adjustment range for stability adjustment and when excitation over voltage, the response from the AVR becomes sluggish. The AVR is equipped with 2 bridging wires J1 and J2 to help improve or relief the condition. See Figure 2. If the unloaded excitation voltage is less than 7 VDC, please cut open the J2 red bridging wires. If the unloaded excitation voltage is greater than25 VDC, please cut open the J1 white bridging wires. GENERATOR OUTPUT(%FROM NORMINAL) 100 90 80 70 60 50 40 30 20 10 0 50 HZ CURVE 60HZ CURVE 5 10 15 20 25 30 35 40 45 FREQUENCY (HZ) 50 55 60 65 70 Figure 3 Frequency Compensation Curves FREQUENCY COMPENATION (See Figure 1) 1. The frequency compensation characteristic of Figure 1 used to improve system load pickup performance by restraining voltage recovery until frequency has also started to recover. 2. The regulator is shipped from the factory set at a 45 Hz corner frequency for 50 Hz systems. For 60 Hz systems, a 55 Hz corner frequency is achieved by removing the 50-50 external link. 3. OPERATION PROCEDURE 3.1 Operational Test Complete the following steps before proceeding with system start-up. 1. Connect the Analog Voltage Controller as shown in the operational test diagram of Figure 8. Do not apply power. Ensure that the light bulbs are rated for 120 volts and less than 100 watts. Figure 4. Operational Test Diagram. 2. Adjust the Regulator voltage adjust potentiometer and remote voltage adjust rheostat (if used) fully counterclockwise. 3. Apply 240 VAC, 60 Hz power to the controller. The light bulbs should flash momentarily. 4. Slowly adjust the controller s voltage adjust potentiometer clockwise. RESULT : 1. Before minimum luminance is reached, the light bulbs should attain maximum luminance to signify the regulation point. 2. At the regulation point, a small change in the voltage adjust potentiometer or rheostat position should turn the light bulbs on or off. 4

3.2 Preliminary Setup Complete the following steps before proceeding with system start-up. Verify that the Regulator specifications conform with the requirements of the generator system. Ensure that the controller jumpers and dip sw are installed/positioned as follows. 1. If a remote voltage-adjust rheostat will not be used, ensure that the Voltage Adjust Rheostat Jumper is connected across terminals 6 and 7. 2. If a 55 hertz corner frequency for a 60 hertz system is desired, connect the Corner Frequency Jumper to the 60 Hz terminal. If a 45 hertz corner frequency for a 50 hertz system is desired, connect the Corner Frequency Jumper to the 50 Hz terminal. Ensure that the connection between the generator system and the Regulator are correct. Set the regulator voltage control potentiometer fully counter-clockwise and the remote voltage adjust rheostat (if used) to the centered position. Adjust the regulator stability control potentiometer fully clockwise. This provides the most stability and the slowest response. If user-adjustment of the under frequency control potentiometer is required, start with the potentiometer adjusted to the fully counterclockwise position. Then, slowly adjust the potentiometer clockwise to set. 3.3 System Start-Up Perform the steps under Preliminary Setup. NOTE : All AC voltage readings are to be taken with an average reading voltmeter. Start Prime-mover and bring up to rated speed. Generator voltage should build up. If it does not build up, perform the steps under Field Flashing. Slowly adjust the regulator voltage control potentiometer (or remote voltage adjust rheostat) until the generator voltage reaches the nominal level. If the voltage does not build up to the rated level : 1. Check the generator output for excessive load or a short circuit. 2. If a minimal residual of 5 volts is not present, perform the steps under Field Flashing. Apply and remove the generator load to verify stability If the generator responds too slowly or hunts (oscillates): Check the generator output for excessive load or a short circuit. Adjust the Regulator stability control with no load applied. Check the stability of the governor system. Check regulation under normal operating conditions. If the regulation is poor: 1. Verify that the prime mover is operating at rated speed. 2. Verify that the voltmeter is connected to the same point as the Regulator sensing. 3. Use an average-sensing voltmeter (not an rms-sensing voltmeter). Verify the corner frequency setting by slowly reducing the generator frequency until the generator output voltage just starts to decrease. If adjustment of the corner frequency is required: 1. Rotate the under frequency control fully counterclockwise. 2. Reduce the generator frequency from nominal (either 50Hz or 60Hz) to the desired corner frequency. 3. Slowly adjust the under frequency control clockwise until the generator output voltage just starts to decrease. CAUTION : All voltage readings are to be taken with an average-reading voltmeter Meggers and high-potential test equipment must not be used. Use of such equipment could damage the semiconductors contained in the controller. 4. FIELD FLASHING When the regulator is operated with the generator for the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 VAC, shut down the Prime-mover and proceed with the following steps : 1. With the Prime-mover at rest and the regulator s field output wires disconnected, apply a DC source ( NOT grounded ) of no more than 6~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.) 5

2. Allow approximately 3 seconds before removing the battery. 3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the residual voltage available at the auxiliary winding. If this voltage is greater than 5 VAC, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 VAC is measured, repeat field flashing procedure. 4. If residual voltage is greater than 5VAC, but AVR still unable to build up voltage, please replace with another AVR. WARNING Please make sure you have read and understand the contents of the instruction manual prior to installation. Incorrect wiring connection may result in irreversible damage to the product and other equipments. This Automatic Voltage Regulator is not equipped with loss-sensing Protection function / Over Excitation Protection. An additional Over-Voltage Protection device for load may be required to avoid possible damage to the equipment or severe personal injury or death. Figure 4 Operational Test Diagram Figure 5 1 Ø 220VAC Diagram Figure 6 3Ø 220VAC Diagram Figure 7 3Ø 380VAC Diagram 6