WiFi Controlled Fused Spur Time Switch

Similar documents
2 Hour Electronic Boost Timer

Digital Economy Seven Programmer

Digital Time Switch. Installation & Operating Instructions

7 Day Digital Programmer 3 Channel Surface Mount

7 Day Digital Time Switch

16 Amp Electronic 24 Hour/7 Day Time Controller

7 Day Digital Light Switch with Optional Dusk Start

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

7 Day Digital Programmer

1. General Information:

24Hour/7Day Electronic Timeswitch

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

SceneStyle2 User Guide

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

MRX1 1. Getting to know your MRX1 wireless controller

Aspect 2 Circuit Digital Scene Control

ServicePlus S17R Series 2 User Operating Instructions

NIGHT WATCHER NW 760 QUICK SETUP GUIDE

18W Low Energy Dusk-Dawn Bulkhead E-290B

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

DD E SIG N E D & E N GIN EE R E. Holman Garden Lights App Instruction Manual. Android Android manual

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

Programmable Room Thermostat With RF

ChannelPlus H17XL Series 2 User Operating Instructions

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

A6 OPERATING INSTRUCTIONS

Identification - electrical services

Product Manual. Designed and Manufactured in the UK by Optikinetics

Radio Thermostat Clock

Automate Pulse Set-Up Instructions

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

FD Trinitron Colour Television

1. Get support Attention Safety Caution Applications View Cameras on Screen (ex. HD TV or PC monitor) 3. Change Time Zone 5

QUICK START GUIDE. IP Camera & NVR Bundle ENGLISH

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Operating Guide. ViewClix offers a revolutionary experience for seniors and their families and friends.

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

TeamWork Kits Installation Guide

Telemetry Receiver Installation Guide

KODAK Video Monitor CFH-V10

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

USER & ENGINEER INSTRUCTION MANUAL

AMPLIFIED INDOOR HDTV ANTENNA WITH WIFI EXTENDER QUICK START GUIDE. Check out setup videos at TRINITYXTN QSG 01

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

Figure 1: Device components

Casambi App User Guide

SBL /SBLG Series Wireless Clock

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

DLP200M 2 Relay Module for Heating and Cooling Plants

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

ST9100C User Guide. Features

Model#: IN-MDRI3MF. Hardware User Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Wireless Irrigation Controller. User Manual.

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

IMPORTANT! This instruction guide explains how to install your CCTV system.

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Introduction. Table of Contents. Thank You for Purchasing Notifi Video Doorbell System INTRODUCTION SETUP HOW TO USE...

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

INSTALLATION & USER GUIDE

Operating Instructions Dimmer for V Incandescent Lamps

CRYPTOPAY QUICK START GUIDE

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

WiFi Time Provider v1 for Arduino Nixie Clock Operating Instructions & Construction Manual

DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

P-2 Installing the monitor (continued) Carry out as necessary

Single Station Waterproof Timer

User manual. Goodmans Product Information:

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

Automotive 72 Exterior Smart Lighting Kit

Casambi App FAQ. Version Casambi Technologies Oy.

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

MS2540 Current Loop Receiver with RS485 Communication

Interactive Satellite Terminal Installation / Validation Manual

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

User guide. ALFRED Light

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

TeamWork Installation Guide

IoT RF HC8301/HC8301A User s Manual

15 Series - Dimmer

MODEL/MODEL/MODEL #6324W-CAM

Power Injector 1520 Series

Telemetry Receiver Installation Guide

TRF STEP-DOWN TRANSFORMER USER MANUAL

CP1 OAD. Owner s Manual. Stereo Control Preamplifier. Ultrafidelity

Hi! Let s get started.

Product information. Front-door station series with video for surface-mount

Transcription:

WiFi Controlled Fused Spur Time Switch Model: FSTWiFi WiFi Controlled Fused Spur Model: FSTWiFiTGV WiFi Controlled IP66 Fused Spur Installation & Operating Instructions

1 1. General Information These instructions should be read carefully and retained for further reference and maintenance. Note: Timeguard reserve the right to alter these instructions, and the SupplyMaster app, at any time. Up to date instructions will always be available for download at www.timeguard.com. 2. Safety Before installation or maintenance, ensure the mains supply to the time switch is switched off and the circuit supply fuses are removed or the circuit breaker turned off. It is recommended that a qualified electrician is consulted or used for the installation of this thermostat and install in accordance with the current IEE wiring and Building Regulations. Check that the total load on the circuit including when this thermostat is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker. To clean use a clean dry cloth only. Do not use liquid cleaners. 3. Technical Specifications Mains Supply: Fused: Rocker Switch: Switch Rating: Contact Type: 220-240V AC 50Hz Supplied with BS1362 13A Fuse 2 Pole, providing isolation 13A Resistive (3kW) 1000W Incandescent, Halogen lighting 500W Fluorescent, LED lighting 100W Compact Fluorescent lighting Normally Open, micro disconnection

2 Wi-Fi Specification: Frequency Range: Operating Modes: Boost Times: Output Light: Operating Temperature: IP Rating: 2.4 GHz b/g/n 2.412 2.484 GHz Permanent ON or OFF, Auto timed, Holiday 1 or 2 hour Yes Minimum Depth of Wall Box: 25mm Multiple Device Support: CE Compliant Dimensions: 0 C to +40 C FSTWiFi Intended for indoor use only FSTWiFiTGV IP66 rated suitable for restricted external applications Yes H = 85mm, W = 85mm, D = 44mm Note: Not suitable for use with Discharge Lighting. ON/OFF indicator Wi-Fi connection indicator Override button and Wi-Fi connect Double pole switch BS1362 (1" x 1/4") fuse

FSTWIFI MAC address and ID Wi-Fi number label Important: Do not remove this label from the side of the product. 3 4. Contents FSTWIFI 1x FSTWIFI time switch 2x Mounting screws 1x Cable clamp 1x Cable blank 1x Instruction manual FSTWIFITGV 1x FSTWIFITGV time switch 2x 20mm cable glands 1x Instruction manual Note: all instructions are to be left with the customer after installation. 5. Installation FSTWiFi Wi-Fi Controlled Fused Spur Note: The unit is designed to replace an existing single gang connection unit or fixed appliance outlet giving timed mains output, protected by a BS1362 fuse. The unit is capable of forming part of a ring main (the terminals can accept 2x 2.5mm sq. cables), or terminating a spur off the ring main. The unit requires a minimum depth of 25mm within the box. 5.1 Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker is turned off.

4 5.2 Connect the incoming 230V 50Hz mains supply and outgoing load cables to the relevant terminals ensuring correct polarity is observed and that all bare conductors are sleeved (see section 6. Connection Diagram). 5.3 There is a removable cable blank to cover the front cable exit if this feature is not required. 5.4 If the front cable exit is required, for instance to connect to a washing machine, use one of the cable clamps provided to secure the outgoing cable. 5.5 Secure the unit to the back box with the M3.5mm screws provided, forming cables during installation to avoid entrapment, and cable damage. FSTWiFiTGV Wi-Fi Controlled IP66 Fused Spur 5.6 IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. 5.7 Using a Phillips screwdriver, separate the faceplate from the back box by removing the four tapped screws located in each corner. Tapped screws

5 5.8 Using the back box as a template mark the position for the holes. Note the back box must be mounted in the correct orientation, following the TOP marking inside the back box. If the mounting position desired is uneven use a sheet of marine ply as a base plate and fit the back box. 5.9 Drill the wall using a 4mm Ø drill bit making sure not to infringe or compromise any gas, water pipes or cables. Insert the rawl plugs into the holes. 5.10 The drain feature must be drilled out using a 5mm drill bit if the top or side entry conduit is used. Opening this drain hole will reduce the IP rating of the product. Only the lower drain feature on the back box must be opened. 5.11 Select the required entry point by unscrewing the appropriate seal located on all four sides of the back box. If conduit is not going to be used, a waterproof cable with suitable rated 20mm glands will be required to maintain the overall IP rating. If the bottom entry conduit is used, there must be adequate drainage from the lowest point of the conduit. 5.12 Secure the back box to the wall using suitable screws for the rawl plugs installed. Ensure that the back box is correctly orientated following the TOP marking which is labelled inside. 5.13 Pass through the 230V AC 50Hz mains supply cable and secure the cables tightly to their respective terminals, ensuring that all bare conductors are sleeved and that correct polarity is observed. Note that if metal conduit is used the earth continuity between the conduits must be maintained. 5.14 Once the mains supply is connected to the correct terminals, mount the face plate to the four mounting holes on the back box. Tighten until secured.

6. Connection Diagram The terminals are marked as follows on the rear of the time switch; Loop terminal for earth continuity Green/Yellow Mains Supply Terminal Live Brown 230V 50Hz Mains Supply Terminal Neutral Blue 6 Switched Live Terminal Load live connection Brown Switched Neutral Terminal Load Neutral connection Blue Internal Schematic L IN BROWN Timeswitch BS1362 Fuse L OUT BROWN 230V AC 50Hz MAINS SUPPLY APPLIANCE N IN BLUE Double Pole Switch N OUT BLUE

7. Setup Note: the mobile or tablet device must be connected to a 2.4GHz band on the router. Pairing on the 5GHz band will result in paring either timing out or being unsuccessful. Refer to your ISP (Internet Service Provider) on separating the bands if required. 7.1 Ensure your phone or tablet is connected to your local Wi-Fi network. 7.2 Download the Timeguard Supplymaster App onto your phone or tablet by searching for Timeguard on Google Play or the App Store. You can also scan the QR code below applicable to your device. 7

8 7.3 Install the App, and open it to the registration page. 7.4 Users must first register, and then log in to use the app. First time users must use the main account log in. Note: Usernames and passwords cannot contain any spaces or special characters, and must use letters and numbers only. 7.5 Then, press the + button (bottom right on the phone s screen to open the add devices menu). 7.6 The network the mobile or tablet is connected to will be shown on the App, enter the password for the network SSID. Important DO NOT PRESS START AS OF YET. 7.7 After entering the password for your Wi-Fi network, name the device you want to add to your account. Note: Device names cannot contain any spaces or special characters 7.8 On the FSTWiFi/FSTWiFiTGV, hold down the override button, until the blue LED light starts to flash. 7.9 Once the blue LED is flashing press start in the App. The App will search for an available device. 7.10 Once the App has found and configured the FSTWiFi/FSTWiFiTGV to the network and your account your device will show up in the devices menu. The blue LED will become solid when there has been a successful connection to your Wi-Fi network. Note: If the device is to be sold, it must be deleted from the App by the main account holder. The device can only be registered to one account at a time.

9 8. Features of the FSTWiFi/ FSTWiFiTGV Device Micro Disconnection The unit offers micro disconnection of the load using the programmed times, or full isolation using the double pole rocker switch on the front of the unit. Micro disconnection can also be applied using the override switch on the front of the unit. Fused protection is also provided. Manual Override The override button on the front of the unit provides a permanent OFF, or ON, until the button is pressed again. It is not overridden by the next program from the App. During the overridden period, the App will show permanent ON, or permanent OFF. The override can be cancelled in the App by putting the mode back to Auto Timed. Light Indicators Red ON/OFF indicator. The red light will turn ON when there is output, and will turn OFF when there is no output. The red light will flash if there is output, but there is no output load detected. Blue Wi-Fi connection indicator. This will illuminate when the device is connected to Wi-Fi, as detailed in section 7. Setup. This indicator will flash only when attempting to connect to the server.

9. Features of the Android and ios App General The app can be accessed, and the device controlled from any accessible Wi-Fi zone. Once Wi-Fi is set up on the device, the App can also control the FSTWiFi/FSTWiFiTGV through 4G. The device must be connected to a Wi-Fi network. There are useful programming tips and help available on the Timeguard YouTube channel. You can access the link directly from our website www.timeguard.com or go to the YouTube home page and search Timeguard. 10

Device Home Screen From log in, the user is presented with a list of devices. Each of these has a device home screen. When a device is selected, the home screen is then shown. Device name Back button Settings 11 Time of next program change Advance button Mode indicator Output indicator Program entry Boost Button

12 Operating Modes The following options are available in mode settings through the device home screen : Auto: Output is controlled by the timer programme, and can be temporarily overridden by boost or advance. Permanent OFF: Output will remain off until auto is re-enabled by the user. In this mode, boost and advance are disabled. Permanent ON: Output will remain on until auto is re-enabled by the user. In this mode, boost and advance are disabled. Holiday: Output is off until the date entered by the user, at which time the program schedule will default back to running as normal. Only one mode can be selected at any time. Permanent OFF, ON, and holiday can be cancelled by returning the App to Auto mode. Boost From OFF, a one or two hour boost can be set using the boost button. A third press of boost will cancel. The duration of the boost is shown on the device home screen, and this will count down the time to the end of the boost period. From ON, a one or two hour boost can be added to the programmed end time. This is shown on the device home screen. Note: Boost will not cross midnight.

Advance Advance changes the output state until the next programmed change. Note: The display will show the next program change: The time of the next programmed change is shown on the device home screen. It also shows the boost time in boost mode (see above). 13 Program Entry The App supports multiple programmed times, with an easy repeat function for different days. Up to 6 times can be added to a program set if required (using the plus key). Time entry is programmed via the program key on the device home page. Hold the chosen time down to edit the times, hold the day MTWTFSaSu to change repeats, or hold the left side of the time box to delete the entire program set via the confirm button. The default times are 06:00 to 08:00, and 18:00 to 20:00 every day. Times can be programmed across midnight. Enter a start and end time before midnight. Enter a second set of times after midnight. Turn off the first end time and second start time using the green sliders. Set the repeats.

Start Time 10:30PM Repeats (MTWTF) End Time 06:30AM Repeats (MTWTF) 14 Quick Programming Tips Up to 6 ON/OFF periods are allowed per program set with weekly repeats. Days can be selected and deselected by touching the day required. If a day is deselected, it shows grey; this would mean that after the last program off time for the selected day ends, no programs will be active until the next selected day within the alternative program set. Alternative Program Periods The App supports multiple alternative programs. This is useful for keeping separate sets of programs, for use in school holidays, periods of non-residency, pre and post summer time, seasonal programs, and periods of unexpected residency such as illness. This means that the original time programs can be saved, and reverted back to when needed, without the need for reprogramming.

Hold the program name to edit or delete, and use the plus key to add new programs. 15 12/24 Hour Clock Times can be shown in either 12 or 24 hour format, in Advanced Settings. Clear ON/OFF Status The device home screen clearly shows output status through both text (ON/OFF), and colour change of advance button (Red OFF, Green ON). Supports Multiple Users Additional users can be added by the Main Account holder, in Advanced Settings, to allow sub account users to control the device. Users can be both added and deleted by the Main Account holder only. All other features of the App are the same. Users are deleted by swiping their name to the left, in the remove users menu which is an option in Advance Settings. Only one Main Account can be registered per device. Sub Account users would use the sub account login option on the login page of the App. Positive Affirmation of ON/OFF Status With output status not enabled (default), the advance button shows red OFF, green ON. Output status will not work unless there is more than 10W, the advance button will remain red, but show the word ON to show that it is programmed ON period, but the device cannot detect the load. Output status shows that the device is working, and will only show a change of state if there has definitely been a change of output state (above 10W).

16 With output status enabled, the advance button will show what is happening with the output. There is an icon on the home screen which shows that this feature has been enabled. If there is no load detected during an on period, the advance button will show red, ON. This is a fault condition as the output is not detected. Once the output has been detected, the advance button shows green, ON. If there has been a load measured at some point in the ON period, but the output can no longer be detected, the indicator will show orange (standby), until the load is detected again, when it will show green. This is common when the output has a secondary control option, such as a thermostat or isolation point between the FSTWiFi/ FSTWiFiTGV and the appliance. Refer to the no load indicator guide video on our YouTube channel for more information on this. Graphical Representation of the Last 24 Hours With output status enabled, there is a graphical representation that compares programmed on times with actual output. This can be used to check the FSTWiFi/FSTWiFiTGV (and the connected appliance) have been working correctly. For appliances with additional controls (for instance thermostats), the output load is not consistently on during the programmed on period. The graphical representation will show this difference. Pink bars represent when there was an output, grey represents the programmed times. Historical Summary There is a brief summary of the last ON period, showing the duration of the period, and the length of time there was an output.

Program Start Time Load Detected Program End Time Time Zones This unit is designed to be used in the UK so will come pre-set to UK time. This cannot be altered. 17 Advanced Settings The advanced settings menu can be found on the devices page via the icon and can do the following: Add User: Allows the main account holder to add additional users known as sub account users. Subaccount users can manipulate the control aspects of the FSTWiFi/FSTWiFiTGV but will not be able to delete the device from the main holder s account. Subaccount users must register via the users option in the advanced settings menu while the main account holder is logged in, this way the App will register any subaccount user to the main account holder s device. IMPORTANT Subaccount users must not register via the registration screen when they download the App, this will result in creating a main account.

18 Remove Users: Allows for the main account holder to remove users from their account. App download: Allows the user to check which version of the App they are using to check for updates. This feature is only available on the Android version of the App. ios users must update the App via the App Store. User manual and FAQ: Provides links to our website, the relevant instructions and to our YouTube channel. About: Provides the company address and contact details for any problems with the unit. Wi-Fi Settings: Allows the user to change the router or extension the device is connected to. Time format: Allows the user to change the time format between a 12/24 hour clock. Privacy policy: Directs the user to the Timeguard privacy policy page on our website. 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture, within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 to 3 or with any difficulty in the first year, telephone our helpline. Note: a proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent.

If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline: HELPLINE 020 8450 0515 or email helpline@timeguard.com Qualified Customer Support Co-ordinators will be online to assist in resolving your query. For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com www.timeguard.com 67.058.560 (Issue 2) Zerofour May 2018