Guided Wave Radar Level Meter. manual of operation

Similar documents
Guided Wave Radar Level Meter

2291 Guided Wave Radar Level Transmitter

Operating Instructions 09/2013

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Operating Instructions 09/2013

Operating Instructions

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Mechanical flow switch for On/Off control

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Sensopress LCD Special English

Level Measurement Point level measurement - RF Capacitance switches

Centurion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series.

Liquid Level Sensor Type AKS 4100U

3 Cleaning. 4 Technical data

Type AKS 4100/4100U Coaxial D14 version

Capacitance Level Measurement Electronic insert FEC 12

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Liquid Level Sensor AKS 4100U

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids ma/hart - two-wire Rod and cable probe

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Level Measurement Point level measurement RF Capacitance switches

Signet 2250 Hydrostatic Level Sensor

EchoPro. LR36, LR41 & LR46 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Radar Liquid & Solid Level Transmitter

Liquid Level Sensor Type AKS 4100/4100U

EchoPro. LR11, LR16, LR21, LR26 & LR31 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Radar Liquid & Solid Level Transmitter

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Modular Lube Lubrication Systems System Controls

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Operating Instructions 09/2017

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids. Profibus PA Rod and cable probe

Operating Instructions

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Installation Guide VL-MV10. Model No.

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids. Foundation Fieldbus Rod and cable probe

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Series Digital Dimmer. User Manual (VER: 2.0) Net.DO LIGHTING CONTROL EQUIPMENT CO.,LTD

Process Transmitter RMA 422

Process transmitter RMA422

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

800 Displaying Series Flowmeter

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

INSTALLATION & USER GUIDE

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

LAUREL ELECTRONICS, INC.

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

Micro-DCI 53ML5100 Manual Loader

Inductive sensor With analog output BI15-M30-LI-EXI

Operating instructions

Rosemount 1151 Smart Pressure Transmitter

Operating Instructions VEGAMET 625 Double channel HART signal conditioning instrument

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Inductive sensor BI1.5-EG08K-Y1

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

DMP 331i / DMP 333i LMP 331 i

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Installation & Maintenance Instructions VEGAFLEX ma/hart - two-wire Rod and cable probe

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Quick Operation Guide of LTN7700/7600 Series NVR

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DISTRIBUTION AMPLIFIER

SCALE & WEIGHT DISPLAYS

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

VITEK VTM-TLM191 VTM-TLM240

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Solis Export Power Manager

Achat 115 Sub A active subwoofer. user manual

DSP 18 Sub active subwoofer. user manual

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

Transcription:

Guided Wave Radar Level Meter manual of operation

Display/Adjustment Adjustments can be done with four buttons on theview point. Optional menu languages are available. View point is only used for display after adjustments. Measurement results would be displayed on the LCD. Display/Adjustment Module 1 LCD 2 Adjustment Keypad [ O K ]Keypad [ ]Keypad -Enter programming mode; -Confirm programming options; -Confirm modifications to parameters. -Choose programming options; -Choose the digit of parameters to edit; -Display the contents of parameters. [ ] Keypad -Modify parameter values. -Enter display mode while running. [ B K ]Keypad -Programming mode exit; -Return to higher menu level. Shortcut [ B K ] Display Echo wave 1

Program instruction Adjustments parameter settings and testings can be done by the four keys on View Point. Program Menu Structure Menu Structure is shown in the appendix. Turn to next menu item pointed by right arrow with OK. Turn to next menu item pointed by down arrow with. Turn to left item with BK. Program Submenu Basic settings Display Diagnostic Service Basic adjustment for the Sensor are included i n this menu. They are min. adjustment, max. adjustment, medium, damping time, Mapping curve, scaled units, scaling, near blanking and sensor tag. In this menu you can setup the sensor display mode and adjust B/ W contrast for LCD. In this menu you can check and test the sensor. You can view the measurement peak values, measurement status, echo-curve and Simulation. In this menu you can store false echo curve and current output, units of measurement, language, rest HART operation mode, copy sensor data and PIN. Info The information of sensor including sensor type, serial number, date of manufacture, software version. Program operation Enter program mode by press. press after each parameter editings. Otherwise the modification will be abandoned. Press to quit program status. Parameters editing Parameter editing The first digit of the edited parameter will be displayed in black background on entering p arameter editing. Modify the digit with. Then you can edit next digit with. After editing, press to confirm and store the modification. Optional item programming Some settings can be done by selecting one of several optional items with and confirm ing with. Program menu instruction 1 Basic settings Basic settings are basic setup of the sensor, such as min/ max adjustment, medium, damping and etc. To bring the sensor to program mode from run mode, press. Then the menu is displayed as below Basic settings 1 Display Diagnostics Service Info Note :The menu item number is displayed on the top right corner. 2

1.1 Min. adjustment The item is one of the two setting points that regulates the linear scaled current output. At main menu(the menu number is 1). Select Basic settings with and confirm with OK. Now the Min. Adjustment is displayed on LCD. t he menu item number is 1.1. Min adjustment 0. 00% 35.000 m ( d) 1. 1 1.346 m ( d) Press OK, you can edit the percentage value. Press OK again, you confirm the modification, and further more you can edit the corresponding distance value. See parameter edition to learn how to edit parameters. 1.2 Max. adjustment The item is one of the two setting points that regulates the linear scaled current output. Pushing enter this menu when the menu item number is 1.1. LCD displays as below Max adjustment 100. 00% 0. 000 m ( d) 1. 2 1. 409 m ( d) Press OK, you can edit the percentage value. Press OK again, you confirm the modification, and further more you can edit the corresponding distance value. See parameter edition to learn how to edit parameters. 1.3 Medium When LCD menu is 1.2, press to enter edit Medium property, LCD displays as below. There are three options to choose from, Liquid, Solid, and Micro DK. By setting the property of the medium, measurement can be made accurately. Medium 1. 3 Liquid Medium Liquid Solid Micro DK 1. 3 1.3.1 Fast level change Pushing OK will enter this menu when it is liquid or solid selection menu and menu item number is 1.3. LCD displays as below Fast level change 1. 4 Yes Push OK enter Fast level change confirmation. LCD displays as below 3

Fast level change 1. 4 Yes No 1.3.2 First Echo When medium is chosen as liquid or solid, LCD menu is 1.3.1, press menu. LCD displays as below: to choose next First Echo 1. 3. 2 Normal Press to enter First Echo menu. LCD displays as below: First Echo 1. 3. 2 Normal Small Big Bigger Biggest Press to choose the way to set First echo. There are five ways: Normal :No adjustments on first echo Small :Decrease first echo by 10dB Big :Increase first echo by 10dB Bigger :Increase first echo by 20dB Biggest :Increase first echo by 40dB 1. 3. 3 (Liquid) Agitated surface When measure medium is liquid, LCD menu is 1.3.2, press enter Agitated surface. LCD displays as below: to choose next menu and Agitated surface 1. 3. 3 No Press to enter Agitated surface menu. Agitated surface 1. 3. 3 Yes No 1.3.3 (Solid) Large When measure medium is solid, LCD menu is 1.3.2, press enter Large angler repose. LCD displays as below: Large angle repose 1. 3. 3 Normal to choose next menu and Press OK to enter Large angler repose menu angler repose 4

Large angle repose 1. 3. 3 Yes No 1.3.4 ( Liquid) Foaming Pushing will enter this menu when the menu item number is 1.3.3. LCD displays as below Foaming 1. 3. 4 No Push OK,enter the submenu of Foaming/ Powder dust confirmation. LCD displays as below Foaming 1. 3. 4 Yes No 1.3.4 ( Solid) Powder dust Pushing will enter this menu when the menu item number is 1.3.3. LCD displays as below Powder dust 1. 3. 4 No Push OK,enter the submenu of Foaming/ Powder dust confirmation. LCD displays as below Powder dust 1. 3. 4 Yes No 1.3.5 Low DK Pushing will enter this menu when the menu item number is 1.3.4. LCD displays as below Low DK 1. 3. 5 No Push OK,enter the submenu of Low DK confirmation. LCD displayed below 5

Low DK 1. 3. 5 Yes No Move arrow with to Select Yes or No for medium with Low DK. Then confirm with OK. 1.3.6 Measuring in tube When measurement is carried through a tube, that is limited for the liquid medium, the tube diametor must be set in menu Measure in tube so as to rectify the measuring error. Pushing will enter this menu when the menu item number is 1.3.5. LCD displays as below Measure in tube 1. 3. 6 No Push OK, enter the submenu of Measure in tube confirmation. LCD displays as below Measure in tube 1. 3.6 Yes No If the selection Yes is comfirmed by required. LCD displays as below OK, the diameter of the tube will be Measure in tube Measure diamet 0000mm 1. 3. 6 press OK, the value can be edited. 1.3. 1 Micro DK When choose Micro DK as medium property, press OK to enter Micro DK setting. Micro DK 1. 3. 1 Empty Span 10. 00m True Lever 0. 00m DK 1. 00 0. 020m ( d) Normally when electronic constant is smaller than 1.4, the direct echo from the medium is low and hard to detect. However by measuring the echo reflected from the base of the vessel, the height of the medium can be measured. Two parameters are needed to be entered here. 1. Height of empty vessel. 2. True medium height or medium electronic constant, these two parameters are related, entering either one is accepted. The precision of parameters will affect the precision of the measurement. Notes: it should be taking cautions while applying the function, Micro DK. When applying this function the system will decide whether use direct echo or echo from the base to take the measurement. 6

1.4 Damping Pushing will enter this menu when the menu item number is 1.3. LCD displays as below Damping 1. 4 OS 1.5 Signal threshold Press, enter editing menu. See parameter edition to learn how to edit the parameter. To confirm the modification with, give up with. Signal threshold menu is used to set the effective echo amplitude noise margin. When the liquid crystal display menu number is 1.4,Press to enter the signal threshold programming, LCD displays as below Signal threshold 1. 5 20mV 1.6 Mapping curve Press, enter editing menu. See parameter edition to learn how to edit the parameter. To confirm the modification with, give up with. Note: This parameter must be professional, according to echo intensity adjustment. This menu define the correlation between the measured value and the current output. linear or non- linear mapping can be selected in this menu. For the non- linear correlations, paramenters setting must be done by a computer previously. Pushing will select this menu when the menu item number is 1. 4. LCD displays as below Mapping curve 1. 6 Linear 1.7 Scaled units Press, enter editing menu. Move arrow with to Select linear or non-linear. Then confirm with. The unit of the scaled output value can be set in this menu. Pushing enter this menu when the menu item number is 1.5. LCD displays as below will Scaled units 1. 7 height m Pushing to enter the editing menu then move arrow with to select the measure word and corresponding uint, confirm by. 1.8 Scaling Used for linear scaled output to set the linear mapping values. Pushing will enter this menu when the menu item number is 1.6. LCD displays as below Scaling 1. 8 0%= 0.00 m 100%= 0.00 m Pushing to enter the editing menu, see paramenter editing for the value editing. Press to confirm the modification. 7

1.9 Sensor Length In order to get correct result, the length of sensor (cable or stick) should be measured first. When LCD menu no. is 4.7, push to enter sensor length menu. LCD displays as below. Sensor Length 1.9 5. 000m( d) Push to set sensor length. Re.p2. parameter editing. After editing, push OK to confirm or push BK to quit. 1.10 Near blanking The Near blanking is an area near the antenna where the correct measurement is impossible. The default value is the minimum set by the manufacture. Press to enter menu Near blanking when the menu item number is 1. 7. See parameter editing to edit the near blangking value and then confirm the modifiation with. Near blanking 1. 10 0.400 m ( d) 1.11 Sensor tag In the menu Sensor TAG you edit a 11-digit measurement loop designation. The character set comprises: Letters from A-Z and Numbers from 0-9. Sensor tag 1. 11 SENSOR See Optional item programming to edit the tag name. 2 Display This menu is used to set display mode. Pushing will select this menu when the main menu item number is 1. LCD displays as below Basic settings 2 Display Diagnostics Service Info Push, you get 2.1 Display value Enter display mode set with. LCD displays as below Display Display value value 2. 1 2. 1 distance Distance Push, you can select different display types of the measured value as shown below 8

Display value 2. 1 shut off map percent distance scaled height current percent Move arrow to point to the type you want, confirm it with. 2.2 LCD contrast adjustment Pushing will enter this menu when the menu item is 2. 1. LCD diplays as below LCD contrast adjust? 2. 2 Adjust the B/ W contrast by pressing, LCD Displays as below LCD contrast 2. 2 Increase contrast with, decrease contrast with.confirm with. 3 Diagnostics The running status of the sensor can be provided by the menu Diagnostics, and furthermore sensor testing can be done. Pushing to select this menu when the main menu item number is 2. LCD displays as below Basic settings 3 Display Diagnostics Service Info 3.1 Peak values Push, you get Peak values record the maximal and mininoal distance. The records can be cleared to zero at menu 4.4. Peak values distance-min distance-max 2.109 3. 1 0.000 m ( d) m ( d) 9

3.2 Meas. Status (measure) Pushing as below Guided wave Radar Operating Instructions to display measuring status when the menu item is 3.1. LCD displays Meas status meas relia bility : 10dB sensor status : OK 3. 2 3.3 Choose curve (echo curve) At this menu, different curves can be selected to be displayed at menu 3. 4, when the menu item is 3.2 press. you get Choose curve 3. 3 echo curve Pushing to select the curve. There are three curves: echo curve, False echo curve and Output trend curve. Choose curve 3. 3 echo curve false echo curve output trend 3.4 Curve Pushing will display the selected curve when the menu item is 3.3. LCD displays as below Curve zoom When the curve is displayed, pushing will enter Curve Zoom function menu. echo curve 3. 4 + 10. 000 02. 384 0. 01 M( d) 8. 91 Move arrow with,select menu ietm for X/ Y axis zoom or unzoom. Then Confirm with. For X axis zoom pushing to mark the start position for zoom, then confirm with. Pushing again to mark the end position for zoom and confirm with. The selected area of the curve will be shown on the whole screen. Exit zoom with. Echo Curve X-zoom Y-zoom unzoom 3. 4 3.5 Simulation Simulation is used to simulate the 4~20mA current output. By current output simulation the accuraey and linearity of the current output can be checked. And the system testing can be carried out. Push to enter Simulation menu when the menu item number is 3.4. LCD displays as below 10

Simulation 3. 5 start simulation Pushing enter Simulation mode selection menu. LCD displays as below Simulation percent current distance 3. 5 Pushing select the Simulation mode. Then confirm with. The corresponding value will be required and then simulation starts. Three types of simulations Percent : the output current is decided by a percent value: 100% is relative to 20mA, 0%is relative to 4mA. Current: the output current is regulated by a current value. Distance: the output current is decided by a distance value.the current output depends on Min. adjustment( see 1.1 ), Max adjustment( see 1.2) and Mapping( see 1.5) 4 Service This menu with professional functios can only be used by trained technicans.they are False echo storage, Reset, sensor settings back up Password setting and etc. Basic settings 4 Display Diagnostics Service Info 4. 1 False echo High sockets or vessel installations, e.g. struts or agitators as well as buildup and weld joints on the vessel walls cause interfering reflections which can impair the measurement. A false echo storage detects and marks these false echoes, so that they are no longer taken into account for the level measurement. A false echo memory should be created with empty vessel so that all potential interfering reflections will be detected. Pushing will enter this menu when the menu item is 4. LCD displays as below. False echo 4. 1 change? Then push, LCD displays as below False echo delete update create new 4. 1 With select Update/Create new/delete a false echo, confirm with. 11

False echo update / create new 4. 1 01. 000m ( d) When you select update create/ new, you are asked to input a distance value for the realecho. Then push to confirm it and to start the operation. It will take some time to store the false echo. Note : Check the distance to the product surface. Because if an incorrect (too large) value is entered, the existing level will be saved as false signal. The filling level would then no longer be detectable in this area. 4.2 Current output Setup the current output mode. Pushing will enter this menu when the menu item is 4.1 LCD displays as below Current output output mode : 4-20mA failure mode : no change min current : 4mA 4. 2 With you get Current output output mode failure mode min current 4. 2 Output mode Select output current as 4-20mA or 20-4mA. 4-20mA mean the Min. level is corresponding to 4mA and the Max. level is corresponding to 20mA. 20-4mA mean the Min. Level is corresponding to 20mA and the Max. level is corresponding to 4mA.When the arrow points at output mode, push you get output mode 4. 2 4-20mA 20-4mA Push, you select the item you want and confirm with. Failure mode Setup the output current on sensor error. Three status are available.when the arrow points at output mode, push, you get item failure mode and confirm with. you get output mode no change 20. 5mA 22.0mA 4. 2 Min. current Setup the minimal output current is 4mA or 3.9mA.When the arrow points at fail mode, push, you get min. current menu. Confirm with. you get 12

min current 4. 2 3.8mA 4mA Select the item you want with and confirm with. 4.3 Reset With the reset function, modified settings are reset. Three subfunctions are available: Basic settings - Reset settings modified with View Point to the default values. Factory settings -Reset special settings as well as basic settings to default values. Peak measured values -Reset the min./max. level records. When the menu item is 4. 2, push, you get Reset 4. 3 select reset Push, LCD displays as below Reset 4. 3 basic adjustment factory settings peak values menu Selcet the item with confirm with. 4.4 Units of measure Two sets of measure system units are available. The metric system and the British system. Units of measurement 4. 4 m ( d) 4.5 Language Push, to edit it. In this menu you can change the language. English and Chinese are available. language 4. 5 english 4.6 HART operation mode Push, to change it. HART offers standard and multidrop mode.the standard mode with the fixed address 0 means output of the measured value as 4 20 ma signal. In multidrop mode, up to 15 sensors can be operated on one two-wire cable. In this menu you determine the HART mode and enter the address for multidrop. 13

HART operation mode 4. 6 standard address 0 Push, you can select HART operation mode. HART operation mode 4. 6 standard multidrop The default setting is standard mode with address 0. 4.7 Copy sensor data In this menu you can back up the sensor settings so as to restore them when neces sary. Copy sensor date 4. 7 Copy sensor date? Push, LCD displays below Copy sensor date 4. 7 copy from sensor copy to sensor Copy from sensor means to save the sensor settings and copy to sensor means to restore the sensor settings. 4.8 PIN In this menu, the PIN is activated/inactivated permanently. Entering a 4-digit PIN protects the sensor data against unauthorized access and unintentional modifications. PIN 4.8 PIN 4.8 enable? or cancel? 5 Info In this menu the most important sensor information can be displayed: Sensor type, e.g. GDRD51 Serial number: 6-digit number, e.g. 123456 Date of manufacture, e.g. 2006-01-01 Software version, e.g. 06.08.28 Pushing will select this menu when the main menu item number is 4. LCD displays as below Basic settings 5 Display Diagnostics Service Info 14

Then pushing enter the Info display menu. LCD displays as below sensor type GDRD51 5. 1 serial number 123456 Pushing LCD displays as below date of manufacture 2006-01 -01 5. 2 software version 06. 06. 28 Example: To display echo curve do as follow: 1 Push to enter program status. Main menu is displayed on LCD. 2 Push twice to select Diagnostics submenu item. 3 Push to enter the submenu menu number is 3.1. 4 Push to enter next menu, the menu number is 3.2. 5 Push again, the menu number is 3.3. 6 Push to enter the curve select menu (3.3). 7 Set arrow to point to Echo Curve with. 8 Push to confirm. 9 Push, the echo curve will be show n. Menu number is 3.4. 10 Push to enter curve zoom menu. 11 Push to select X zoom. 12 Push to confirm. 13 Push to mark the start position. 14 Push to confirm. 13 Push to mark the end position. 14 Push to confirm. The area of the curve you select will be shown on the whole screen. 15 Push several times to return to run state. Note: Shortcut key can display echo curve on measurement mode, but it has no zoom functions. 15

Appendix Basic settings 1 Display 2 Diagnostics 3 Service 4 Min adjustment 1. 1 Max dajustment 1. 2 medium 1. 3 Fast level change 1.4 damping 1. 5 Guided wave Radar Operating Instructions info 5 Mapping curve 1. 6 linearity consumer programme 1. 5 Scaled units 1. 7 scaling 1. 8 Sensor Length 1. 9 Near blanking 1. 10 Display value 2. 1 Sensor tag 1. 11 shut off map percent distance scaled height current percent LCD contrast 2. 2 Peak values 3. 1 Distance-min distance-max Meas status 3. 2 meas relia bility sensor status Choose curve 3. 3 Echo curve false echo curve output trend Echo curve 3. 4 Curve zoom X -zoom simulation 3. 5 Percent current distance Y-zoom Unzoom 1X 2X 5X 10X 16

Basic settings 1 Echo curve 4. 1 delete update create new Display 2 Current output 4. 2 output mode failure mode min current Diagnostics 3 Service 4 Reset 4. 3 Select reset Basic reset factory settings peak values info 5 Units of measurement 4. 4 M (d) ft(d) language 4. 5 chinese english HART operation mode 4. 6 Standard multidrop Copy sensor copy from sensor data 4. 7 copy to sensor PIN 4. 8 sensor type serial number 5. 1 date of manufacture software version 5. 2 17

3 Installation Guide Within the measurement range, determined not to come into contact with the cable or rod internal obstacles, Therefore, the installation should be avoided as far as possible the tank facilities, such as: human ladder, limit switches, heating devices, stand etc. Also note that the cable or rod may not intersect with the material during feeding. Also note that when installing the meter : Highest Level measurement can not enter into the blind; Must be maintained between the instrument and the tank wall a certain distance; When the meter is installed, try to stick with cable or perpendicular to the surface of the measured medium. Meter installation in hazardous areas must comply with state regulations explosion hazardous installation area. Intrinsically safe instrument requires the use of shell with aluminum. Intrinsically safe instrument can be installed in explosion-proof requirements of the occasion, the instrument must be connected to the earth. Measurement reference plane is the sealing surface of the thread. 1 Blind Range (Menu 1.9) 2 Cable Length (Menu 1.8) 3 Max.Measurement Range (Menu 1.2) 4 Min.Measurement Range (Menu 1.1) 5 reference Plane The following guidelines apply to the installation of the cable and the rod radar level measuring solid powder or liquid. Installation position: Far away from the discharge port and inlet. Metal cans in the entire measuring range, not to touch the tank wall and tank bottom. Recommended meter installed in 1/4 or 1/6 of the silo diameter, and the minimum distance is 1/10 of the tank wall of the measuring range. Cable type or rod probe the minimum distance from the tank wall 300mm. Bottom of the probe from the tank bottom 30mm. The minimum distance from the probe obstructions 200mm. If the bottom of the container is a cone, you can install a central tank top. 18

Below is a single rod radar level meter installation drawings, mainly used for liquid level measurement Features: You can measure any dielectric permittivity of 1.8. Generally used to measure viscosity 500cst, not prone to adhesion medium. Rod radar maximum range of 6 m. Instrumentation for steam and foam has a strong penetrating power, the measurement is not affected. For a lot of foam liquid measurement environment, you should select a single rod guided wave radar level meter measurement. Guided wave Radar Operating Instructions Below is double rod radar level meter installation drawings, mainly for low dielectric constant liquid and solid lightweight powder measurements Features: For low dielectric constant of the liquid and light solid powder, can double cable measurement mode, in order to ensure accurate measurements. You can measure the dielectric constant of 1.6 in any medium. Generally used to measure viscosity 500cst, not prone to adhesion medium. Double cable radar level meter maximum range of up to 30 meters. Installation Method: Reasonable meter installation to ensure long-term reliable and accurate measurement Guided Wave Radar Level Meter can be connected by threaded, thread length should not exceed 15mm, also can be installed on a short tube. When installing a short tube diameter of 2 "to 6", the installation of a short tube height should 100mm ( Thread length and short tube shorter measurement will be more stable), If you install a short pipe is longer, it is best to cut it short, or using insulation bracket fixed cable type probe, avoiding probe in contact with the short end of the pipe to further to affect the measurement. Screw installation Short tube installation short tube diameter: 2''-6''(DN50-DN150) 19

DN200 or DN250 installed in the short tube When guided wave radar level meter need to be installed at the short pipe diameters greater than 200mm, the short tube wall will produce an echo, the medium in the case of a low dielectric constant can cause measurement errors. Therefore, with a diameter of 200mm or 250mm short tube, you need to choose a special flange with a "horn Interface" of. Installation Notes on plastic containers Whether cable or rod type, if you want to guided wave radar is working properly, the process of connecting to the metal surface should be. When the guided wave radar mounted on a plastic pot, If the tank top is plastic or other non-conductive material, the instrument needs with metal flanges, the use of threaded connections, to be equipped with a metal plate. Optimized interference Interference echo suppression : Software can be realized on disturbance echo suppression, to achieve the desired measurement results. 20

For a medium viscosity of less than 500cst, can bypass pipe or waveguide (Only for liquids) to avoid interference. Guided wave Radar Operating Instructions Installation of low dielectric constant of the liquid For dielectric constant greater than 1.3, the viscosity 500cst, and is not easy adhesion medium, guided wave radar meter can be installed in the waveguide is measured, has the following characteristics: superior reliability, high-precision Can be used in any medium of dielectric constant 1.3, it doesn't matter between measurement and conductive medium. obstructions and short pipe size does not affect the measurement Corrosive media measurement If the measurement of corrosive media, the choice of rod or cable probe sets PTFE, PFA sleeve measurement. installed in horizontal and vertical tank on tank Rod probe can be up to six meters, more than six meters for measuring distances tank, the choice of 4mm rope probe. Installation and fixation with the same measurement of solid powder compartment. Distance from the tank wall 300mm, the probe must avoid contact with the tank wall. In the choice of probe length, note at the bottom of the probe from the tank bottom distance> 30mm. If obstructions are more, or too close to the probe by the sensor, it can then be measured by installing tube waveguide. The matters needing attention: To be measured in the waveguide radar, generally used in rod probe sensors, during installation You should use insulated bracket fixed probe, ensuring rod probe with concentric waveguide, or they will have a very strong false echoes. When measuring range exceeds the maximum measuring range rod probe should be used in guided wave radar probe cable, In this case waveguide diameter should be greater than or equal to 6 ", otherwise it will generate strong false echoes. Installation of right and wrong 4 Wrong: Do not install the meter above the feed inlet stream, cable or rod should avoid material entrance. Correct: Note: when installed outdoors take shade, rain measures 21

Moisture: For instruments installed outdoors or indoors and wet cooling or heating of the tank, in order to moisture, should tighten the cable jacket, but also to the cable at the inlet bend downward, as shown in Figure 4 Structure Size(Unit: mm) 5 The Electrical Connection Power Supply (4~20) ma/hart(two-wire) Power supply and current signal are carried by the same two-wire connection cable. See the Technical Specifications of this guide for 22

detailed requirement on power supply. A safety barrier should be placed between power supply and instrument for intrinsically safe version. (4~20) ma/hart(four-wire) Power supply and current signal are carried by two 2-wire connection cables respectively. See the Technical Specifications of this guide for detailed requirement on power supply. Earth-connected current output can be used for standard version of level instruments, while the explosion proof version must be operated with a floating current output. Both instruments and earth terminals should be connected with ground firmly and securely. Normally you can either choose to connect with the earth terminal on vessel or adjacent ground in case of plastic vessels. Cable Connection General Introduction (4~20) ma/hart(two-wire) (4~20) ma/hart(four-wire) Shielding and wiring Supply cable can use ordinary two-core cable, the cable diameter should be (5 ~ 9) mm, to ensure that the cable entry seal. If electromagnetic interference exists, recommended to use shielded cable. Supply cable can use ordinary two-core cable. Supply cable should be used with a dedicated ground cable. The two ends of shielded cable must be connected with earth terminal. The shielded cable must be connected with inner earth terminal directly inside the transducer, while the outside earth terminal on housing must be connected with ground. In the event of earth-connected current, the shielding side of shielded cable must be connected to ground potential via a ceramic capacitor (e.g. 1 F/1500V) in order to dampen the low frequency grounding current and avoid the disturbance caused by high frequency signals. Wiring Diagram 24V 2-wire: 6 23

220V 4-wire: Explosion Proof Connection The intrinsic safety version sensors (Exia IIc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia IIc T6. A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: Exia IIC, voltage of power supply: 24V DC ± 5%, short-circuit current: 135mA, operating current: 4...20mA. All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor 0.1 μ F/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used. Explosion Proof Zone None-Explosion-Proof Zone Adjustment with SOFTware 24

Safety instructions: Please observe the local electrical code requirements! Please comply with local requirements for personnel health and safety regulations. All electrical components of instrument operation must be completed by the formal training of professionals. Please check the instrument nameplate to provide product specifications meet your requirements. Please make sure that the power supply voltage and instrument nameplate on the requirements. Protection Grade: The instrument fully meet the requirements of protection class IP66/67, make sure the cable head waterproof seal. As shown below: How to ensure that the installation meets IP67 requirements: Make sure that the sealing head is not damaged. Make sure that the cable is not damaged. Make sure the cable is used in line with the electrical connection specifications. Before entering the electrical interface, the cable is bent downwardly, to ensure that water does not flow into the casing, see 1 Please tighten the cable sealing head, see 2 Keep electrical interface with blind unused block after block tight, see 3 6 Adjustment Instructions Adjustment Methods: 1 Display/adjustment module ViewPoint) 2 An adjustment software 3 HART handheld programmer 25

Display / Adjustment Module ViewPoint is a pluggable display/adjustment module. The adjustment can be done through operating with four buttons on ViewPoint. Optional menu operation languages are available for selection. ViewPoint is only used for display after adjustment in that the measurement results can be seen clearly through the glass window. Display / Keypad 1 Liquid Crystal Display 2 Adjustment Keypad PC debugging Connect with another unit through HART 1 RS232 Connect Cable /USB port 2 Radar level meter 3 HATR port adapter used on COMWAY convertor 4 250 ohm Resistance HART Handheld Programmer Adjust meter with HART Handheld Programmer 1 HART Handheld Programmer 2 Radar level meter 3 250 ohm Resistance 26

7 Technical Specification General Parameters Probe Material: Rod Cable Coax Seal Process Connection Shell Seal ring between the shell and the shell ViewPoint Window Ground Terminal Stainless Steel 316L/PTFE Stainless Steel 316L/PTFE Stainless Steel 316L/PTFE Viton fluoroelastomer, Kalrez perfluoroelastomer Stainless Steel 316L Stainless Steel 316L, Plastic,Aluminum Alu-die casting, Powder Coated Silicone Rubber Polycarbonate Stainless Steel 316L Power 2-Wire Standard Version (16~36)V DC Intrinsic Safe Version (21.6~26.4)V DC Power Consumption max. 22.5mA Ripple Allowed - <100Hz Uss < lv - (100~100K)Hz Uss < l0mv 4-wire Intrinsic Safe + Explosion-Proof (22.8~26.4)V DC,(198~242)V AC Power Consumption max. 1VA,1W Parameters on Cable Cable Entry/Plug Spring Connection Terminal One cable entry of M20xl.5 (cable diameter of 5~9mm) One blind stopper M20xl.5 Applicable for cables with cross section of 2.5mm Output Output Signal Resolution Failure mode 2-wire load resistance 4-wire load resistance (4~20)mA/HART 1.6μA 20.5mA;22mA;3.9mA, hold See the diagram below Max.500 ohm 27

Integration Time ( 0~40)sec, adjustable Technical data Max Measurement Distance 701 30m/6m(Cable /Rod) 702 20m/6m(Cable /Rod) 703 30m/6m(Cable /Rod) 704 6 m 705 15m/6m(Cable /Rod) Measurement Interval About 1sec (Depend on parameter settings) Adjustment Time About 1sec (Depend on parameter settings) Resolution of Display 1mm Accuracy ±10mm(See the accuracy illustration diagram below) The accuracy illustration diagram Temperature for Storage/Transport (-40~80) Process Temperature (Probe) 701 704 (-40~250) 702 (-40~200) 703 (-40~150) 705 (-200~400) Relative Humidity <95% Pressure Max. 40MPa Vibration Proof Mechanical vibration 10m/s², (10~150)Hz 28

Max Pulling Force See the illustrative diagram on pulling force When measuring solid medium, the pulling force is determined by the diameter of vessel and medium level, some examples of pulling force generated by typical medium are shown on the diagrams below. 12 29

Guided Wave Radar Level Meter