CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Similar documents
ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

Agilent High Capacity RV Pumps & Roots Pumping Systems

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Dry Compressing Vacuum Pumps. Dry Com. CLAWVAC Claw Vacuum and Overpressure Pumps

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

Dry Compressing Vacuum Pumps

THE ULTIMATE DRY CHOICE

Magnetic Stirrers Magnetic Stirr

Type D mechanical diaphragm

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Admiss. counterpressure

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Dry Com. Dry Compressing Vacuum Pumps

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

PRIMEROYAL Series. Metering Pump. Model PN

GRUNDFOS alldos product information. The solution for complex dosing tasks

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

DMP 331i / DMP 333i LMP 331 i

Pendant Light Fitting IEC Series 6470/2

AGILENT ROUGH VACUUM PUMPS

Quality products from a single source

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

istep STEPPER MOTOR PUMP

Okta 1000, Roots pump without motor

SMALL OIL SEALED PUMPS

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

82540/ /2-way diaphragm valves

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Series description: Wilo-Jet HWJ

Series description: Wilo-Drain VC

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

2.9 Sigma/ 2 Plunger Metering Pumps

Capacitance Limit Detection nivotester FTC 420/421/422

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

TFRN Industrial RTD temperature sensor. CombiTemp TM

SR Series. Spring Return dosing pump D - mechanical diaphragm. The right dosing choice

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

Nessie Coils for VDH and VDHT valves

Smart Standard. With ProCam Smart Bran+Luebbe offers a high quality, economic pump for the customer with less demanding applications.

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

TFRN Industrial RTD temperature sensor. CombiTemp TM

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Quality products from a single source

New SV series / Holger Falk / Distributor meeting Page 2

Electromagnetic Block Valves Direct Acting

Solenoid valves VZWD, directly actuated

Inductive sensor BI1.5-EG08K-Y1

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

istep STEPPER MOTOR PUMP

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Continuous level measurement - Capacitance transmitters

Part-Turn Electric Multi-Turn Electric

Circuit-Breakers for Motor Protection Series 8523/8

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

A3H series. Energy and cost efficient solutions for the most demanding applications. Multi-stage. Roots pumps

ih Series Drypumps (505) idealvac.com idealvac.com

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Parts List _2.1. Flygt /.890

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Inductive sensor NI10-M18-Y1X-H1141

Gear Pump Units For single-line centralized lubrication systems

PROPORTIONAL VALVES Sentronic plus

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Inductive sensor With analog output BI15-M30-LI-EXI

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Gear Pump Units. For single-line lubrication systems

PRIMEROYAL Series API 675 metering pump

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

Revision 2.0 Parts List Minor

Inductive sensor NI3-EG08K-Y1-H1341

PMG. Vibration Energy Harvesters

Tekna evo. innovation technology future 03

Single Point Flow Monitor SW118 SW119

Spring Return dosing pump FM - mechanical diaphragm

Varian, Inc. Vacuum Technologies Industry Leading Vacuum Performance High Capacity MS-Series Rotary Vane Pumps & RPS-Series Roots Pumping Systems

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

Transcription:

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 EX Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is transferred using automatic valves. The gas-bearing parts of the chemically resistant gas pumps are made of modified PTFE, so they are able to withstand even highly aggressive gases and vapors. The N 922 FT.29 E provides an integrated bypass valve to better adjust the flow rate to the current process conditions. Pumps and pump drives in this product series are explosion proof according to 2014/34/EU (ATEX). Features Pure transfer No contaation of the media due to oil-free operation Maintenance-free Explosion proof versions to ATEX Motor approved in accordance with IECEx Chemically resistant for transferring highly aggressive and corrosive gases and vapors High level of gas tightness approx. 6 x 10-3 m l/s Long product life Very quiet and little vibration Cool running motor even when in constant use Version with adjustable flow rate Can operate in any installed position Areas of use These pumps are required especially in the fields of analytical technology, chemistry industry and production technology as well as research. The pumps transfer, compress or draw highly aggressive gases and vapors, take samples as sample gas pumps (or liquid samples using vacuum), evacuate vessels or transfer aggressive and explosive gases as process gas pumps in chemical facilities. (l/) (m absolute) atm. Pressure ( g) 16L, 50 Hz 16 7.2 8L, 50 Hz 7.5 7.2 16L, 60 Hz 18 7.2 8L, 60 Hz 9 7.2 Weight (kg)

N 922 FTE EX MOTOR at atm. (l/)1) Max. operating ( g) Ultimate vacuum (m abs.) 16L, 50 Hz 8L, 50 Hz 16L, 60 Hz 8L, 60 Hz 16 ± 10 % 7.5 ± 10 % 18 ± 10 % 9 ± 10 % 1) Protection class Voltage (V) Frequencies (Hz) Power P1 (W) lmax (A), 50/60 Hz IP 66 230 50/60 195 1.09A Liter at STP PUMP EXPLOSION PROTECTED Pump head Diaphragm modified PTFE PTFE-coated Valves/ Sealing FFPM Protection class IP 54 Pump parts AC motor Ex II 2G c IIB + H2 T3 X Ex II 2G Ex de IIC T4 N 922 FTE EX * EU-Version: G1/4 (2x) US-Version: 1/4-18 NPT (2x) ** EU-Version: 22, 0.5 tief/deep (2x) US-Version: nicht vorhanden/non-existent N 922 FTE EX 16L FLOW CURVE N 922 FTE EX 8L FLOW CURVE atm. += += atm. m abs. Flow rate detered at 20 C, 1013 mabs (Pressure 0 to 1013 mabs in accordance with ISO 21360-1/2) += += m abs. Flow rate detered at 20 C, 1013 mabs (Pressure 0 to 1013 mabs in accordance with ISO 21360-1/2)

N 922 FT.29 E EX MOTOR at atm. (l/)1) Max. operating ( g) Ultimate vacuum (m abs.) N 922 FT.29 E Ex 16L, 50 Hz N 922 FT.29 E Ex 8L, 50 Hz N 922 FT.29 E Ex 16L, 60 Hz N 922 FT.29 E Ex 8L, 60 Hz 10 16 ± 10 % 3 7.5 ± 10 % 12 18 ± 10 % 4 9 ± 10 % 1) Protection class Voltage (V) Frequencies (Hz) Power P1 (W) lmax (A), 50/60 Hz IP 66 230 50/60 195 1.09A Liter at STP PUMP EXPLOSION PROTECTED Pump head Diaphragm N 922 FT.29 E Ex modified PTFE PTFE-coated Valves/ Sealing FFPM Protection class IP 54 Pump parts AC motor N 922 FT.29 E Ex Ex II 2G c IIB + H2 T3 X Ex II 2G Ex de IIC T4 N 922 FT.29 E EX * EU-Version: G1/4 (2x) US-Version: 1/4-18 NPT (2x) ** EU-Version: 22, 0.5 tief/deep (2x) US-Version: nicht vorhanden/non-existent N 922 FT.29 E EX 16L, 50 HZ FLOW CURVE N 922 FT.29 E EX 8L, 50 HZ FLOW CURVE atm. Flow rate detered at 20 C, 1013 mabs (Pressure 0 to 1013 mabs in accordance with ISO 21360-1/2) N 922 FT.29 E EX 16L, 60 HZ FLOW CURVE m abs. Flow rate detered at 20 C, 1013 mabs (Pressure 0 to 1013 mabs in accordance with ISO 21360-1/2) N 922 FT.29 E EX 8L, 60 HZ FLOW CURVE atm. atm. m abs. atm. m abs. Flow rate detered at 20 C, 1013 mabs (Pressure 0 to 1013 mabs in accordance with ISO 21360-1/2) m abs. Flow rate detered at 20 C, 1013 mabs (Pressure 0 to 1013 mabs in accordance with ISO 21360-1/2)

TECHNICAL INFORMATION N 922 FTE EX N 922 FT.29 E EX 16L PUMP UP TIME FOR 20 LITER VESSEL N 922 FTE EX N 922 FT.29 E EX 16L PUMP DOWN TIME FOR 20 LITER VESSEL m N 922 FTE EX N 922 FT.29 E EX 8L PUMP UP TIME FOR 20 LITER VESSEL N 922 FTE EX N 922 FT.29 E EX 8L PUMP DOWN TIME FOR 20 LITER VESSEL m ACCESSORIES Description Order No. Tube fitting for tube ID 6, PVDF 303623 Mounting kit shock mounts 313180 Mounting kit shock mounts and mounting bracket 313181

HINTS ON FUNCTION AND INSTALLATION Function of KNF diaphragm gas sampling pumps An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuate and compress completely oil-free. Hints on installation and operation Range of use: Transferring air and gases at temperatures between +5 C and +50 C. Use in potentially explosive atmospheres for equipment group II, categories 2 G and for authorized gases of group IIB + H2 up to temperature class T3. Permissible ambient temperature: between +5 C and +50 C. Please check the compatibility of the materials of the pump head, diaphragm and valves with the medium. The pumps are not designed to start against or vacuum; when a pump is switched on the in the suction and lines must be atmospheric. Pumps that start against or vacuum are available on request. To prevent the maximum operating being exceeded, restriction or regulation of the air low should only be carried out in the suction line. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Install the pump so that the fan can draw in suficient cooling air. KNF reserves the right to make changes. KNF Neuberger, Inc. Two Black Forest Road Trenton, NJ 08691 USA Tel. 609-890-8600 Fax 609-890-2838 knfusa@knf.com www.knfusa.com KNF 08/2018