DALI TOUCHPANEL BASIC TW. Operating and control unit

Similar documents
LED Driver Compact fixed output

Emergency lighting units EM powerled

Emergency lighting units EM powerled

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

LED Driver Compact dimming

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

LED Driver Compact fixed output

LED control gear Compact fixed output

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Constant voltage

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED Driver Compact dimming

LED Driver Compact dimming

LED Driver Linear / area dimming

LED Driver Compact dimming

HID control gear Electronic

LED Driver Compact dimming

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Figure 1: Device components

Benefits. Applications

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

LED MODULES READYLINE DL

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

Emergency lighting units EM INVERTER

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Thank you for purchasing a qualiton APR204 preamplifier!

SY-MS121 SY-MS121-AP

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

DLP200M 2 Relay Module for Heating and Cooling Plants

LUXPOINT TM MIDI 6 LED Downlight Data Sheet

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

DLP600M 6+1 Relay Module for Heating and Cooling Plants

SY-HDBT-100 Extender Set

Gamma instabus. Technical product information

SY-HDBT-SLIM-100S Extender Set

Trusted 40 Channel 120 Vac Digital Input FTA

OT 100/ /700 P5

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Trusted 40 Channel 120 Vac Digital Input FTA

MICROMASTER Encoder Module

OPTOTRONIC Intelligent

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Technical Information

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

Catalogue Ignitors and power switches for HID

Installation Guide VL-MV10. Model No.

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Thank you for purchasing a qualiton PHONO preamplifier!

Trusted 40 Channel Analogue Input FTA

Installation Guide. HDMI 4x1 Switcher

Operating instructions

Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

Input Control. Input Voltage Range. Model. 2 Vin - 0.2~0.5V % SLD-DimTW V 2 2 Vin - 0.2~0.5V 5. 7 SLD-DimTW

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

Operating instructions III / 2004

KRF EMC Filters Installation, Operation and Maintenance Manual

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

Preliminary Data sheet

TRF STEP-DOWN TRANSFORMER USER MANUAL

PRODUCT MANUAL. Product Description. Waterproof 4 Channel DMX to RGB-W LED Controller

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

Indoor Linear 80W Driver SI-C215280N2KR

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

3M Sensored Termination (15 kv) QX-T15I-vi1-E

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

PHASED OUT. Control module with 3 channels/single, twin push to make switches/ presence detector/modulardim power supply

/ PAT01 USER MANUAL

R xx-C0900-J074

CHIMEI INNOLUX DISPLAY CORPORATION

Roof-mounted Blue e+ cooling unit Integration solution VX25

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

User Manual. HDBT-EC Set. 4K HDBaseT Extender HDMI HDBaseT Extender Pair with PoC & Bi-Directional IR Support 4K UHD

Transcription:

BASIC Operating and control unit Product description Capacitive Touchpanel High-quality appearance with real glass display Multiple control modules are possible in a system Power supply via line Double terminals for through wiring Adjustment of lighting group with rotary switch 5-year guarantee BASIC C BASIC G Type C / Type S: Individual adjustment of start number of lighting scenes with Scene rotary switch Type TW: Tunable white (colour converter) control (colour temperature along the Planckian Locus, Colour temperature Tc) BASIC S BASIC TW È Wiring diagrams and installation examples, page Data sheet 1/1-CO9- www.tridonic.com 1

BASIC Operating and control unit Technical data Supply via cable Current draw 1 ma Interface Ambient temperature ta... +5 C Max. casing temperature tc C Storage temperature ts... +5 C Humidity 5 %... max. 5 % (non-condensing) Type of protection IP Casing material PC Casing colour RAL 91 (white) Installation in concealed box: ø x 1 mm (ø x H) Dimensions (L x W x H) x x 9.1 mm 9,1 19,, 5, 5 D D 1 1 1 1 1 1 Scene Ordering data Type Article number Model Packaging, carton Weight per pc. BASIC C 19 Combination 1 pc(s)..1 kg BASIC G 19 1 pc(s)..1 kg BASIC S 199 Scene 1 pc(s)..1 kg BASIC TW 199 Tunable White 1 pc(s)..1 kg Data sheet 1/1-CO9- www.tridonic.com

1. Standards IEC 1-1 IEC 1--11 IEC 15 1.1 standard BASIC is designed to control control gear with standard IEC 99 ( V) and IEC ( V1).. Settings The BASIC Models Combination,, Scene and Tunable White are multi-functional devices for circuits. Every model offers touch sensitive fields with unique functionalities to control your light. An additional position LED allows easy location of the BASIC in dark areas. The combination of different rotary selector switches combined with the variety of BASIC models offers an easy way to reach a high degree of flexibility without the need of additional programming. The easy configuration options are also efficient for easy replacement because only the rotary selector switch position has to be copied and no need of additional programming..1 Scene / switch Depending on the model one or two rotary selector switches are available. As a function from the position of the rotary switch different Scene or commands can be send to your installation. Rotary selector switch Scenes Rotary selector switch Position Recall Scene Position Broadcast 1 1 1 1 5 5 5 5 9 9 9 1 1 1 9 11 11 11 1 1 1 1 11 1 1 1 1 1 1 1 1 15 15 15 1. Rotary selector switch The rotary selector switch has 1 positions. Default setting is position as illustrated in the picture below. 1 1 1. Short / long press When in this documentation an short press is mentioned it means that the time of contact with the touch panel field was under 5 ms. Every contact longer than 5 ms will be recognized as a long press and will depending on the model send a different command than the short press. Short press < 5 ms < long press. Quick start guide If you do experience any issues with your installation make sure to follow the following quick start guide. Step 1: Make sure Drivers connected to the line are addressed, grouped and Scene values are saved as preferred. Info: In case other Tridonic lighting components are used the commissioning of the line can easy be achieved by using the Tridonic Software masterconfigurator in combination with the USB via a Windows PC. But it can also be done by using other standard commissioning tools of different manufacturers. Step : Program your according to your needs. The programming is done via the rotary selector switches on the back of the panel. The exact functionality for every model is explained separate in the following chapters. Step : Mechanically install and wire your as described in the chapter wiring. is not SELV so the roles for mains voltage installation have to be applied! Step : Once all components are configured and installed make a test of your installation to get sure everything works as programmed. If you have issues with your installation please check out our quick start guide which can be found on our webpage www.tridonic.com there you will find more information about, how to commission a line and troubleshooting help. Data sheet 1/1-CO9- www.tridonic.com

. Interfaces / communication.1 BASIC C 1 1 5 D D 1 1 1 1 1 1 Scene BASIC Combination offers two rotary selector switches the rotary selector switch allowing to select if a 1 or the whole line via Broadcast should be controlled. The Scene rotary selector switch allows to recall Scene values 15. Default position of the rotary selector switches and Scene is in this position Scene, 1 and will be recalled and all commands will be send via Broadcast to the whole line. 1 Broadcast go to Scene Broadcast go to Scene 1 Broadcast go to Scene Broadcast dim up 5 Broadcast dim down Broadcast toggle between recall max/off Postion LED activate/deactivate with long press default activated If the rotary selector switch Scene is in position 1 then Scenes 1, 15 and can be recalled and if the rotary selector switch is in position then all commands will be send to 1. No other will react to the send commands. 1 1 go to Scene 1 1 go to Scene 15 1 go to Scene 1 dim up 5 1 dim down 1 toggle between recall max/off. BASIC G 1 G1 G 5 G D D 1 1 1 BASIC can control up to s. Which s should be controlled can be selected with the rotary selector switch on the back. Default position of the rotary selector switch is in this position the whole line can be controlled via Broadcast and in addition and 1 can be controlled separately. 1 Short press Broadcast recall max Long press Broadcast dim up Short press Broadcast off Long press Broadcast dim down Short press recall max Long press dim up 5 Short press off Long press dim down Short press 1 recall max Long press 1 dim up Short press 1 off Long press 1 dim down If the rotary selector switch is in position 1 then s 1, 1 and the whole line Broadcast can be controlled. 1 Short press 1 recall max Long press 1 dim up Short press 1 off Long press 1 dim down Short press 1 recall max Long press 1 dim up 5 Short press 1 off Long press 1 dim down Short press Broadcast recall max Long press Broadcast dim up Short press Broadcast off Long press Broadcast dim down Data sheet 1/1-CO9- www.tridonic.com

. BASIC S 1 1 5 5 D D 1 1 1 1 1 1 Scene BASIC Scene offers two rotary selector switches on the back. The Scene rotary selector switch allows to select which Scenes should be recalled and the rotary selector switch allows to control for which the Scenes should be recalled. Default position of the rotary selector switches and Scene is in this position Scene 5 will be recalled and all commands will be send via Broadcast to the whole line. 1 Broadcast go to Scene Broadcast go to Scene 1 Broadcast go to Scene Broadcast go to Scene 5 Broadcast go to Scene Broadcast go to Scene 5 If the rotary selector switch Scene is in position 1 then Scenes 1, 1, 1, 15 and will be recalled and if the rotary selector switch is in position 1 then the Scene commands will be only recalled for 1. No other will react to the send commands. 1 1 go to Scene 1 1 go to Scene 1 1 go to Scene 1 1 go to Scene 15 5 1 go to Scene 1 go to Scene 1. BASIC TW 1 5 D D 1 1 1 BASIC Tunable White allows an easy way to control Tunable White luminaries and offers one rotary selector switch on the back. Depending on the position of the rotary selector switch different s 1 or the whole line can be controlled. Default position of the rotary selector switch is in this position commands will be send as Broadcast commands to the whole line. 1 Short/long press Broadcast step warmer Short/long press Broadcast step cooler Short/long press Broadcast recall colour temperature value, K Short/long press Broadcast dim up 5 Short/long press Broadcast dim down Broadcast toggle between recall max / off If the rotary selector switch is in position 11 then 1 will be controlled, no other will react to the send commands. Following commands will be send out to the line. 1 Short/long press 1 step warmer Short/long press 1 step cooler Short/long press 1 recall colour temperature value, K Short/long press 1 dim up 5 Short/long press 1 dim down 1 toggle between recall max / off Data sheet 1/1-CO9- www.tridonic.com 5

. Installation / wiring.1 Wiring diagram L N D D BASIC C D D BASIC G D D BASIC S D D BASIC TW L N PS Driver LCA 1 G1 G G 1 5 Driver LCA. Wiring type and cross section wire preparation:.1 1.5 mm².5 5.5 mm The wiring can be solid wire or stranded wire with a cross-section of.1 to 1.5 mm².. Installation and safety instructions: is not SELV. Apply the installation instructions for mains voltage Installation: fixed only, in a clean and dry environment Supply: via control line only; no mains voltage allowed control line: use standard installation material for low-voltage systems (< 1 V); only tree, linear and star topologies permitted; cores may be reverse connected Terminals D1/D: do not connect with mains line Terminals: when using solid conductors, connect only one per terminal The Touchpanels do send and Scene commands. Make sure your devices are grouped and Scene values are saved correctly Handle with care, the glass may be damaged if dropped, burned, punctured or crushed Static electricity, sweat, oil and other impurities on your hand or on the touch panel may result in a not responsive touchscreen. If this happens please make sure to clean the touch panel and your hands. The device may only be used for the application area specified Relevant health and safety regulations must be observed While assembling and installing the device, the voltage supply must be disconnected Only qualified personnel may assemble, install and commission the device If an error occurs, dangerous voltage levels may be present at the terminals and on the control line Data sheet 1/1-CO9- www.tridonic.com

5. Miscellaneous 5.1 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. Data sheet 1/1-CO9- www.tridonic.com