Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Similar documents
PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Overview: Specifications: Installation Instructions:

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

SSPT724A Timer Quick Start Guide

XTM72E & F Real-Time Clock Modules

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

XTM72 Exerciser Timer Module

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

LCS-2. Low Voltage Lighting Control Relay Processing Panel. Operator s Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Installation and Operation Manual. YMP Series Signal Programmer

Master Time Clock MTC Users Manual

INSTRUCTION MANUAL HN 50. Master clock MOBATIME BE

TORK MODEL DZM200A 2 CHANNEL DIGITAL TIME SWITCH WITH MOMENTARY CONTACT

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

TORK MODEL DWZ100A 1 CHANNEL DIGITAL TIME SWITCH

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Junior Max (JR Max ) Controller

Softwired Clock. Total Lighting Control. Catalog Number: RCLK8SWS DESCRIPTION FEATURES. Installation Instructions IMRCLK8SWS 1

Master Clock Controller. User Guide. pyramidtimesystems.com

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

Master Clock Controller. User Guide. pyramidtimesystems.com

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Instruction Manual for Programmable Digital Timer

Master Clock Controller. User Guide. pyramidtimesystems.com

Automatic Transfer Switch Control PLC Operator s Manual

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Innovative Air Systems ABN When Calling For Support Quote:.doc

ET BLU MIX RX-Condo-3

Operating instructions. Universal timer switch display

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Radio Thermostat Clock

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

) AMANO. ,i CINCINNATI ELECTRONIC TIME RECORDER EX 6000 SERIES

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

7 Day Digital Light Switch with Optional Dusk Start

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Model 1476-C SuperQuad HR

1 Channel Multi-Purpose Programmer User Instructions

Battery Operated Controllers

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

Intelligent Security and Fire Ltd

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

video door entry system - installation instructions

Active UTP Transceiver Hub Installation Guide

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

MSC+ Controller. Operation Manual

Operation Guide 6022 ENGLISH

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Multifunction Digital Timer

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

Programmable time switches Multiple function - daily/weekly

Installation Instructions

WDK-2500-STROBE. User Guide

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Electronic 1-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

Operations. BCU Operator Display BMTW-SVU02C-EN

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Electronic Timer Control Day Astronomic Electronic Control

REV 303 PROGRAMMABLE MULTIFUNCTIONAL TIMER. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics OPERATING MANUAL.

TDDFM14 OWNER S MANUAL

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Digital Real Time Recording VCR

Access Control Keypad for MK-DV, JB-DV

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

User s Guide. Dimensions 4000 Series Control System. Topics at a Glance

ex 800 Series ematrix System

Single Axis Position Controller

Art M Digital codelock module

Digital Timer. 1 About your Slimline Digital Timer. 2 Mechanism Dimensions. Cat No. D817SLIMDP Instruction Manual

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

MODEL 2018 OPERATION MANUAL Firmware Version

User s Guide. GreenKeeper 212 Features: Automatic Sprinkler System Controller

ST9100C User Guide. Features

QUARTZ TIME RECORDER. Simplex 300 OPERATION MANUAL

Electronic 2-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

AP21 BELL / BUZZER SYSTEMS

User s Guide. ECx Features: Automatic Sprinkler System Timer

Transcription:

Two (2) Channel 365 Day 24 Hr. Timer/Controllers Models include: PT2724 - Timer module PT2724E - Timer module in enclosure Installation Guide Rev. 020317 More than just power. TM

Overview: Altronix PT2724/PT2724E is an extremely versatile two channel 365 Day 24 Hour Timer/Controller designed to support a wide range of applications. Such applications include: Home and Building Automation, Security, Access Control, Lighting Control, etc. The timer is equipped with two independently controlled form C relay contact that provide many latching and/ or momentary operations during a program schedule of your choice. The EE-Prom memory allows for programming of unit prior to or during field installation. Events may be set for single or multiple operations on a daily and/or weekly schedule. The block programming feature enables repeating an event on any combination of consecutive days. PT2724 will compensate for daylight savings time if desired. It automatically adjusts for leap year and individually selected holiday exceptions can be programmed to override regularly scheduled events. Input: 12 to 24 VAC or VDC operation. Relay: Two (2) form C relay contacts are rated 10A @ 120VAC/28VDC. Standby current: 10mA (relay off), 50mA (relay on). Tandem relay mode allows both channels to activate simultaneously for all events. Features: EE Prom memory protects against loss of programming due to power failure. Accurate crystal controlled clock. Momentary and/or Latching Events. 50 individually programmed daily/weekly events. Block programming capacity can accommodate a total of 350 events per week. 10 programmable Holiday dates per channel. First man in option. Specifications: Features (cont d): Standard or Daylight Savings Time settings. Automatic compensation for leap year. Visual Indicators: Alphanumeric LCD display simplifies programming. Battery Backup: Built-in charger for 12VDC sealed lead acid or gel type batteries (Max charge current 100mA). Optional lithium battery backup maintains clock. Order Altronix part # LB2032. Mechanical: PT2724 - Timer module. Board Dimensions (approx.): 5.25 x 3.6 x (133.4mm x 91.4mm x 25.4mm). PT2724E - Timer module in enclosure. Enclosure Dimensions (H x W x D approx.): 8.5 x 7.5 x 3.5 (215.9mm x 190.5mm x 88.9mm). Installation Instructions: 1. Mount PT724A/PT724AE/DPT724A in desired location. Carefully Review: Basic Operation (pg. 3) Terminal Identification Table (pg. 3) Push Button Layout and Description (pg. 4) Programming Instructions (pg. 4-7) 2. Connect 12 to 24 volts AC or DC to terminals marked [+ DC / ~ AC ~]. When using DC carefully observe polarity. 3. Connect 12VDC battery (optional) to terminals marked [+ BAT / 12VDC]. 4. Insert lithium battery (optional/not included. Order part LB2032) in battery holder (Fig. 1, pg. 3) with the + positive side facing up. 5. Connect devices to be controlled to dry relay outputs marked [NO, C, NC] of either Channel A or Channel B. Note: It is important when connecting DC powered electromechanical devices such as Mag Locks, Electric Strikes, Bells, Relays, etc. to install a catch diode across the pos (+) and neg ( ) terminals of the device. Connect diode as close to the device as possible with the banded side facing the pos (+) terminal. This will reduce the possibility of interference. 6. Program clock and desired event schedule (see programming instructions pg. 4-7). - 2 - PT2724

Basic Operation: PT2724 controls two independently operated dry form C relays. Relays can be programmed to: turn on (latch), turn off (release latch) or pulse (momentary toggle) at a specified time and day (this is referred to as an event). Events are programmed via the push buttons and LCD display. Events may be programmed to occur on any day of the week at any time. In addition, events may be programmed as a block events that repeat at a specific time on two (2) or more consecutive days (i.e. MO-FR, SU-TH, etc). Multiple combinations of individual and block events may be programmed. Holiday exceptions are individually selected by date and will override all regularly scheduled events. Output Relay Modes: Mode Status Relay OFF De-energizes the relay until a relay ON event is detected. Relay ON Energizes the relay until a relay OFF event is detected. Disable Used to cancel an existing programmed event. Pulse Momentarily energizes the relay for a selectable time period of 1 sec. to 15 secs. Time is displayed in 24 hr. military format. Terminal Identification Table: Terminal Legend NO, C, NC, CH A NO, C, NC, CH B + DC ~ AC ~ + BAT 12VDC FM Function/Description Dry Contact outputs used to switch controlled devices. When these relays are energized (ON) the NC and C terminals are open and the NO and C terminals are closed. When this relay is de-energized (Off) the NC and C terminals are closed and the NO and C terminals are open. AC or DC Input 12 to 24 volt. When using DC carefully observe polarity 12VDC stand-by battery input (battery leads provided). When this terminal is connected to DC neg. ( ) the First Man in feature is enabled. The relay will remain in its present position until this connection is terminated. At that time the relay will resume normal operation and latest scheduled events will occur. Fig. 1 NO C NC NO C NC ON SW2 RELAY ON SU 01:01 SW3 + DC AC + BAT 12VDC FM SET ENTER UP DWN 12-24 Volt AC/DC input 3V Lithium Battery Socket (Altronix part # LB2032) PT2724-3 -

Push Button Layout: Push Button SET ENTER UP DOWN SET ENTER UP DWN Push Button Description Table: Function/Description Scrolling keys for programming. Escaping out of existing programming. Accepts selections made to programming. Scrolls through selections. Scrolls through selections. UP and DOWN keys can be used to select data entries. After scrolling to the correct entry, depress accept. SW2 DIP Switch SW3 Slide Switch Selects tandem or individual relay operation. Selects channel to be programmed. A. Setting Clock/Calendar: Upon initial power up Programming Instructions: RLY OFF SU 01:01 Depress SET.. SET TIME 01/01/01 SU/01:01 Enter the current date, day of week and time (military) by depressing UP and DWN to make the selection, then depress accept. Next, select either DS (daylight savings mode) or ST (standard time mode) by depressing SET until SET BK Depress scroll until flashing cursor appears under DS (daylight savings mode) in display. To change mode depress UP or DWN until ST (standard time mode) will appear in display. Depress accept correct selection. Note: The flashing cursor denotes location of data entry selection to be made. If an entry was made in error or requires changing, depress SET to backspace, make the correct selection and depress accept data and advance the cursor. To change or program clock/calendar simply repeat the steps above. B. Setting and Adding Events: Note: Channel cannot be changed in the middle of programming events. To change channels, you must exit programming then change channel switch position then enter program mode again. 1. Setting Events. SET EVENT A01 OFF SU 00:00 Note: A01 indicates Channel A event 01. When cursor appears, you are able to scroll through events. - 4 - PT2724

until the flashing cursor appears under OFF (relay function) position in display. Now select type of event required, by scrolling using the UP and DWN push buttons until either: ON - Relay ON (latching mode), OFF - Relay OFF (latching mode), PL - Relay Pulse ( momentary) appears in display. Depressing ENTER will make selection. When selecting the pulse mode, PL01 will appear in the display. It is now necessary to assign the length of time (duration of relay activation). The pulse can range in length from 1 second minimum to 15 seconds maximum and is selected by using UP or DWN push buttons, then depressing accept. Note: If pulse duration is not selected, relay output defaults to 1 second. Next, select individual day of the week and time (military) by scrolling using UP and DWN push buttons and depress accept. You may continue to program events by repeating the previous steps or exit programming by depressing SET. Note: When programming additional events, it is necessary to select the next consecutive event number following the last event program to continue. Note: When it is required to have the same event repeated on two (2) or more consecutive days of the week (Block Programming), the event must be programmed as a block by selecting BK in the day field. A01 OFF BK 00:00 Note: To program the consecutive days of the week refer to Setting Block Event (weekly repeat) and Daylight Savings Time - section C1 below. 2. Adding Events SET EVENT A01 OFF SU 00:00. If the event is not programmed, the cursor will move to the OFF (relay function) position. If the event is programmed, the cursor will move to the position and the programmed information of the event will be displayed. At this point depress the UP button to step up through the programmed events. When an unprogrammed event is reached, the cursor will move to the OFF (relay function position). At this point refer to setting events or setting holiday events. C. Setting Block Events (weekly repeat) and Daylight Savings Time: Note: Channel cannot be changed in the middle of programming events. To change channelsyou must exit programming then change channel switch position then enter program mode again. SET BK. A=SA/SU TIME=DS 1. Block Event Programming Flashing cursor will appear at the location of the first day of the week desired. Depress UP and DWN to select day. Depress confirm selection, then cursor will appear at the location of the last day of the week desired. Depress UP and DWN to select day. Depress confirm selection. 1) Monday through Thursday depress MO followed by TH. 2) Wednesday through Sunday depress WE followed SU. 2. Daylight Savings Programming The cursor will appear under DS (auto clock adjust daylight savings mode) in display. To change mode depress UP or DWN once ST (clock does not adjust standard time mode) will appear in display. Depress accept correct selection. Note: Select DS for areas that observe daylight savings or ST for areas that don t observe daylight savings. PT2724-5 -

D. Setting Holiday Events: (These events will occur on programmed Holiday Dates - see Setting Holiday Dates below). Note: When a holiday event is entered, all holidays will follow that event. Note: Channel cannot be changed in the middle of programming events. To change channels you must exit programming, then change channel switch position then enter program mode again. Find the first unprogrammed event (refer to Adding Events - section B2 page 6). until the flashing cursor appears under OFF (relay function) position in display. Now select type of operation required, by scrolling using the UP and DWN push buttons until either: ON - Relay ON (latching mode), OFF - Relay OFF (latching mode), PL - Relay Pulse ( momentary) appears in display. Depressing ENTER will make selection. When selecting the pulse mode, PL01 will appear in the display. It is now necessary to assign the length of time (duration of relay activation). The pulse can range in length from 1 second minimum to 15 seconds maximum and is selected by using UP or DWN push buttons, then depressing accept. Note: If pulse duration is not selected, relay output defaults to 1 second. Next select HL (holiday) and time (military) by scrolling using UP and DWN push buttons and depress accept. Exit programming by depressing SET. If no holiday event has been entered and a holiday date is entered, the unit will stay in its last position when that date comes up. Note: When a holiday event is entered, all holidays will follow that event. E. Setting Holiday Dates: Note: Channel cannot be changed in the middle of programming events. To change channels you must exit programming, then change channel switch position then enter program mode again. It is now necessary to assign these holiday events specific calendar dates which they are to occur on. SET EVENT Enter the holiday date, day of week and year by depressing UP and DWN to make the selection then depress accept. Note: Holiday events will override all regularly programmed events that occur on a particular holiday date. F. Delete/Disable Events or Edit Events: Note: Channel cannot be changed in the middle of programming events. To change channels you must exit programming, then change channel switch position then enter program mode again. Previously programmed regularly scheduled and/or holiday events may be deleted/disabled without having to erase all events. A01 HOL SU 00:00 SET EVENT A01 ON TU 00:00 Now scroll using UP and DWN push buttons to the event you wish to delete, depress move flashing cursor under relay option, then depress UP and DWN. Push buttons until DIS is displayed, depress confirm. G. Delete All Events: This will delete all previously programmed events. CLR MEM CLEAR MEMORY? PRESS UP & ACCEPT Depressing UP push button will now clear all events previously programmed. If you wish to escape from this selection depress any of the other push buttons: SET, ENTER and DOWN. - 6 - PT2724

H. Tandem Relay Mode: To operate in the Tandem Relay Mode, turn switch SW2 ON. This mode setting will allow events programmed for Channel A and Channel B to operate both relays simultaneously (1 DPDT relay output). This setting doubles the amount of programmable events. Note: When using the Tandem Relay mode, sequential On/Off or Off/On events must be programmed in the same channel. (If there is a Channel Program conflict, such as CH A is set to ON and Channel B is set to OFF. The ON command will override the OFF and both relays will remain ON. PT2724 Board Dimensions (L x W x H approximate): 5.25 x 3.6 x (133.4mm x 91.4mm x 25.4mm). 0.14" 3.6mm Ø0.156" 3.9mm 0.14" 3.6mm 4.9" 124.5mm 2.4" 61mm 3.6" 91.4mm 5.25" 133.4mm PT2724E Enclosure Dimensions (H x W x D approximate): 8.5 x 7.5 x 3.5 (215.9mm x 190.5mm x 88.9mm) 7.25 (184.15mm) 3.625 (184.15mm) 1.25 (31.75mm) 3.5 (88.9mm) 1.25 (31.75mm) 0.6 (15.24mm) 6.05 (153.67mm) 0.6 (15.24mm) 2 (50.8mm) 1.125 (28.575mm) 1.125 (28.575mm) 2 (50.8mm) 8.125 (206.375mm) 0.6 (15.24mm) 6.05 (153.67mm) 0.6 (15.24mm) 1.25 (31.75mm) 3.5 (88.9mm) 5.25 (133.35mm) PT2724-7 -

Customer Event Log Event # Relay # Day/Block Holiday Dates Event Type Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA phone: 718-567-8181 fax: 718-567-9056 website: www.altronix.com e-mail: info@altronix.com Lifetime Warranty Made in U.S.A. IIPT2724 F21R MEMBER - 8 - PT2724