Copyright 2018 Geophysical Survey Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form

Similar documents
UtilityScan TM LT. Quick Start Guide. A Fast Check List For Field Operation

TeamWork Kits Installation Guide

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

Practice, Practice, Practice Using Prototek Digital Receivers

Dynatel Advanced Cable Locator 2250

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

TeamWork Installation Guide

May result in personal injury or property loss. Indicate the behaviors that must be prohibited

Model 570 Fiber Optic

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

SIR, RADAN, UtilityScan, PaveScan are registered trademarks of Geophysical Survey Systems, Inc.

P-2 Installing the monitor (continued) Carry out as necessary

Dejero LIVE+ 20/20 Transmitter

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

AX20. Atlas 19.5" 3G-SDI/HDMI Field and Studio Monitor with 3D LUTs & Scopes. Quick Start Guide. What s Included CHECKED BY

Hi! Let s get started.

High Resolution Concrete Imaging

Delvcam DELV-FPV-7 User Guide

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Model#: IN-DI2MIRF 2MP Indoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

HDMI Over IP Extender Kit - 4K

Troubleshooting CS800/LC900 Bikes

Product model and standard

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

9070 Smart Vibration Meter Instruction Manual

Quick Start Guide Camera Slot Dual UHF Receiver

28 4K LED monitor. User Manual M284K

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

LED Backlight for Technics amplifiers

Hi-Rez Projections Inc. 20 Main St. Ashland, MA MP8 CRT Installation

Activity P32: Variation of Light Intensity (Light Sensor)

User Manual. SWIT ELECTRONICS CO., LTD Model: S-4904P Wireless HD Transmission System(with Panel Receiver) Ver:A

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller

Gordian. Multifunctional Power Distributor / Conditioner. v1.3

VXF7 QUICKSTART GUIDE. 7" 4K Full HD HDMI/3G-SDI On-Camera Monitor

WaterVue TV Installation & User Manual

XB-68 RF Detector & Camera Finder

Elite Screens Frequently Asked Questions. Screens FAQs

Wall-/Pipe-Mount Level Indicator

LM/TM-30xx, 31xx Series LCD Monitor User s Manual Rev. A0

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

SX7. Saga 7" Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs. Quick Start Guide. What s Included CHECKED BY

If you have any problems please contact our office at Thank You! And Enjoy! Like us on Facebook /AllenLeighSC

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

1. Get support Attention Safety Caution Applications View Cameras on Screen (ex. HD TV or PC monitor) 3. Change Time Zone 5


The Evolution of Video Conversion

DataSAT ACU-2 Controller Wiring Configuration - Operation

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc.

DLP200M 2 Relay Module for Heating and Cooling Plants

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Warning and Safety Information. FCC Information

USER MANUEL. SNIPE 2 Ref R13

What is SnoCam? SnoCam Installation Guide. SolarVu

Assembly instructions

Field Service Procedure Receive Path Troubleshooting

TeamWork 601 Kit Installation Guide

Receiver Description and Installation

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

Home Monitoring. Wired Color Camera. User Manual. For indoor/outdoor use. Do not use in wet locations.

VITEK VTM-TLM191 VTM-TLM240

Getting started with

S7H-DK S7H 7" High Bright Monitor Deluxe Kit

Model#: IN-MDRI3MF. Hardware User Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04

IMPORTANT SAFETY INSTRUCTIONS

Fully ly Automaticti. Motorised Satellite t TV System. User s manual. ver 3.0.

W 9-2: A Versatile, Complete and Compact Series

DH5e QUICKSTART GUIDE. 5" 4K Support HDMI On-Camera Field Monitor w/ Touch Screen

Delvcam DELV-HD7-4K User Guide

IMPORTANT SAFETY INSTRUCTIONS Please read User Guide before using this product. Please keep User Guide for future reference. Please read the cautions

DH7-DK QUICKSTART GUIDE. DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit

7 3G -SDI Monitor w/ Signal Conversion QUICKSTART GUIDE

DH5e-V2. Delta 5 On-Camera 4K HDMI Monitor with 3D LUTs. Quick Start Guide. What s Included

Quick Setup Guide. DCX-500i / DCX-1000i / DCX-1500i Projectors with WC-Pro Scaler. Preliminary

imso-104 Manual Revised August 5, 2011

Be sure to run the vehicle engine while using this unit to avoid battery exhaustion.

Personal Information Page

1 Unpack. Taking the TV Out of the Box. Included in this Box. Stand Parts and Cables. Remote Control. Also included

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

Simple and highly effective technology to communicate your brand s distinctive character

120cm (4x36 Watt) incl. Splitter Instruction Manual

INSTALLATION INSTRUCTIONS FOR

GRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle.

COPYRIGHT NOVEMBER-1998

Register your product and get support at SWW1800/12. Quick Start Guide. Connect. Install. Enjoy

Hi! Let s get started.

LWX-1. Satellite Weather Radio Module Installation Instructions A

Capstone Experiment Setups & Procedures PHYS 1111L/2211L

LBS-1 (Lowrance Broadband Sounder)

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Site Installation Model MP-8433

W100L: Laser Sensor in Mini- Format

3 Locating and Marking Products DOCUMENT OBSOLETE

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Site Installation Model MP-8424

CU103 User Manual. Contents

Transcription:

MN36-268 Rev A

Copyright 2018 Geophysical Survey Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form Published by Geophysical Survey Systems, Inc. 40 Simon Street Nashua, NH 03060-3075 USA Printed in the United States SIR, RADAN, UtilityScan and PaveScan are registered trademarks of Geophysical Survey Systems, Inc.

Table of Contents Section 1: Introduction...1 About this Guide... 1 LineTrac Physicals... 1 Section 2: Electromagnetic Theory and LineTrac...2 Section 3: Installation...3 Section 4: Software Setup and Use with the UtiIityScan Pro...4 Configuring the SIR 4000... 4 Power Mode... 4 Frequency Mode... 5 Data Examples: Power Mode... 5 Data Examples: Frequency Mode... 8 Section 5: Software Setup with the UtiIityScan DF/HS... 11 Configuring the UtilityScan Tablet... 11 Power Mode... 11 Frequency Mode... 12 Data Examples: Power Mode... 12 Data Examples: Frequency Mode... 15 Section 6: Software Setup with the UtiIityScan with Built-in LineTrac... 18 Configuring the UtilityScan... 18 Power Mode... 18 Frequency Mode... 19 Data Examples: Power Mode... 19 Data Examples: Frequency Mode... 21 MN36-268 Rev A

MN36-268 Rev A

Section 1: Introduction Thank you for purchasing the LineTrac, an optional accessory for GSSI s UtilityScan systems utilizing digital antennas. LineTrac integrates traditional utility line locator technology with GSSI s renowned ground penetrating radar (GPR) expertise. LineTrac data is seamlessly overlaid on GPR data to combine two of the most important tools used for detecting underground utilities. This guide is meant to familiarize the user with installation, setup, use and data interpretation of the LineTrac. LineTrac is a one-piece accessory employing a three-axis magnetometer that, by itself, can detect the 50/60 Hz magnetic signal created by live, loaded alternating current (AC) electrical power lines. When paired with a third-party signal transmitter directly coupled or inductively clamped to a utility, LineTrac can detect these active signals. About this Guide This document discusses tips about how to collect and interpret data using LineTrac and refers to use of third-party signal transmitters. There are numerous AC signal transmitter manufacturers and products on the market and GSSI can only speak in generalities about the use of these transmitters. It is incumbent on the user to read and consult the operator s manual of any AC signal transmitter that is to be paired with LineTrac. LineTrac Physicals 1 Rugged, IP 65 rated enclosure 2 Push-pull LEMO Connector to digital GSSI antenna 3 Secure four-point mounting to antenna 3 1 2 MN36-268 Rev A 1

Section 2: Electromagnetic Theory and LineTrac While GPR and electromagnetic line location are both termed electromagnetic techniques, the principles behind how each work are quite different. LineTrac works because of the principle of electromagnetic induction. A current flowing through a linear conductor generates a circular, magnetic field perpendicular to the conductor. This magnetic field can induce a voltage in a second conductor if this second conductor is placed in close proximity AND at the correct orientation to the magnetic field. Inside LineTrac are three such conductors, the magnetometers, in horizontal, vertical, and transverse orientations. When LineTrac moves through a magnetic field a weak current is induced in the preferentially aligned magnetometer. A current flowing through a buried utility occurs in two general ways. The first is termed Passive : the utility is naturally carrying a current along its length. Examples of this are AC power lines. The second is termed Active : an AC signal transmitter is actively creating a current on the utility. LineTrac can detect the first in Power Mode and the second in Frequency Mode. All currents are not created equally and detectable by LineTrac. An Alternating Current (AC) regularly changes its direction and polarity. How often this change occurs in a given time determines the frequency of the current, measured in cycles/second or Hertz (Hz). For most electrical power grids, this frequency is either 50 Hz or 60 Hz, with 60 Hz being the main frequency generated in the United States. Direct Current (DC) maintains a constant direction and magnitude and has no frequency to be detected by LineTrac. An energized AC line that is not under load (for example, an electrical wall outlet with no appliance plugged into it) has a voltage but no current. Without an AC current moving through the line there will be no magnetic field to be detected by LineTrac. The stronger the current flowing through a line the more identifiable the line will be to LineTrac. Note voltage has no effect on detectability. AC signal transmitters have a selection of different frequencies they can generate. The exact selections will be manufacturer dependent but in general they will span from low (example 29 Hz) to high frequencies (example 33 khz). There are advantages and disadvantages to each frequency and the proper selection of frequency will depend on many factors, including but not limited to: Soil Conductivity Number and proximity of conductive, buried utilities in an area. Length/distance of the utility to be located. The higher the frequency the better the signal can conduct along a utility. The tradeoff of this superior signal conductance is the signal can be induced ( bleed ) on neighboring conductive utilities and lead to incorrect locates. The lower the frequency the more difficult for the signal to conduct along a utility but, once established, the longer distance the signal can be detected over. MN36-268 Rev A 2

Section 3: Installation LineTrac is simple to install on GSSI s digital antennas, the 350 Hyperstack (HS) and the 300/800 Dual Frequency (DF). 1 Unscrew the 4 machine screws from the top, front of the digital antenna. Align the mounting plate of the LineTrac over the holes and reinstall the 4 machine screws to secure the LineTrac. 2 Note: If using the digital antenna battery bracket or the antenna handle mount (AKA shark fin) in conjunction with the LineTrac, the two are installed as a stack with the LineTrac on the bottom and the other accessory on top. 3 Push the LEMO connector on the end of the cable into the Accessory port of the digital antenna, making note line up the red dot on the connector with the red hash mark on the accessory port. Assemble the rest of the UtilityScan system. 4 Note: There is only one proper alignment to plug the LineTrac connector into the antenna port. Forcing the connector into the port using an incorrect alignment may result in damage to the connector and/or the port. 5 It isn t necessary to install and remove LineTrac for each use but to unplug the LEMO connector from the digital antenna, firmly grasp the connector below the black, rubber gasket and pull up. Grasping and pulling from the top of the connector or the cable may result in damage to the LineTrac. 6 When LineTrac is properly attached and the UtilityScan system is powered ON, a green light on top of the LineTrac will illuminate. If the light doesn t illuminate unplug the LEMO connector and inspect for damage. LineTrac can be plugged/unplugged to a powered antenna with no damage to LineTrac or the antenna. Mounting Plate and four Screws LEMO Connector MN36-268 Rev A 3

Section 4: Software Setup and Use with the UtiIityScan Pro Configuring the SIR 4000 The SIR 4000 control system is the heart of the UtilityScan Pro system. Using the Digital 2D mode of the SIR 4000 will allow the user to configure the LineTrac settings. Please refer to the SIR 4000 User Manual for a comprehensive discussion of all other SIR 4000 settings and functionality. Turning on LineTrac: Before changing the collection settings of LineTrac it first must be activated. This is done on the Setup Screen in the Radar Menu, where LineTrac is the last setting and defaults to Off. 1 Highlight LineTrac, press Enter to select the menu. 2 Change the setting to On, then press enter again. Power Mode and Frequency Mode will now be visible. Power Mode This mode is used to detect AC current flowing through energized electric lines. LineTrac can detect AC current with frequencies of 50 Hz or 60 Hz, the two predominant frequencies of electrical power grids worldwide. 1 Highlight Power Mode and press Enter to activate the setting. 2 Select 50 or 60 from the menu and press Enter. 3 The data preview screen will reset and you will see a blue line superimposed on the GPR data. This blue line is the LineTrac data and upon setup will appear quite ragged, with the exception if the UtilityScan system is being setup in very close proximity to a 60 Hz current (not recommended). MN36-268 Rev A 4

Frequency Mode This mode is used to detect the AC current flowing along a conductive utility generated by an AC signal transmitter. LineTrac can detect a wide range of AC signals with 12 industry standard frequencies selectable. 1 Highlight Frequency Mode and press Enter to activate the setting. 2 Select the frequency to match the signal being generated by the signal transmitter from the menu and press Enter. 3 The data preview screen will reset and you will see a yellow line superimposed on the GPR data. This yellow line is the LineTrac data and upon setup will appear quite ragged, with the exception if the UtilityScan system is being setup in very close proximity to the AC signal transmitter (not recommended). Note: It is possible to collect both Power and Frequency data at the same time, though it can create a cluttered data screen. Data Examples: Power Mode UtilityScan Pro Power Mode: Data Set 1-A The above image shows the ragged blue LineTrac data characteristic of no detectable flowing current. What the LineTrac is recording and displaying is the ambient AC signal present in the background. Most GPR data collected with LineTrac will initially look like this. MN36-268 Rev A 5

UtilityScan Pro Power Mode: Data Set 1-B The above image is a continuation of the proceeding image, but the UtilityScan system is approaching a buried electric line. The LineTrac data automatically rescaled as a stronger AC current was detected. UtilityScan Pro Power Mode: Data Set 1-C The above image is a continuation of the proceeding image and the UtilityScan system has completed traversing the buried electric line. The LineTrac data displays a completed peak with a slight null point at its midpoint and there is a corresponding reflection in the GPR data. MN36-268 Rev A 6

UtilityScan Pro Power Mode: Data Set 1-D The UtilityScan s backup cursor function was used to identify the GPR reflector corresponding with the LineTrac data, and the horizontal cursor used to determine the depth of the buried electrical line. UtilityScan Pro Power Mode: Data Set 2-A The above image shows data collected crossing a road with overhead power lines on the far side. The LineTrac data has rescaled itself and is beginning to ramp up but the UtilityScan system is still approximately 20 feet from being under the power lines. MN36-268 Rev A 7

UtilityScan Pro Power Mode: Data Set 2-B The above image is a continuation of the proceeding image and the UtilityScan system has completed crossing under the overhead lines. A very broad hump is displayed instead of a sharp peak. Data Examples: Frequency Mode UtilityScan Pro Frequency Mode: Data Set 1-A The above image shows the ragged yellow LineTrac data characteristic of no detectable tracing frequency. A 33kHz signal has been coupled to a buried natural gas line but the UtilityScan system is still some distance away. Again, most GPR data collected with LineTrac will initially look like this. MN36-268 Rev A 8

UtilityScan Pro Frequency Mode: Data Set 1-B The above image is a continuation of the proceeding image, but the UtilityScan system is approaching the buried gas line. The LineTrac data automatically rescaled as a stronger 33 khz signal was detected. UtilityScan Pro Frequency Mode: Data Set 1-C The above image is a continuation of the proceeding image and the UtilityScan system has completed traversing the buried gas line. The LineTrac data displays a completed peak with a distinct null point at its midpoint and there is a corresponding reflection in the GPR data. MN36-268 Rev A 9

UtilityScan Pro Frequency Mode: Data Set 1-D The UtilityScan s backup cursor function was used to identify the GPR reflector corresponding with the LineTrac data, and the horizontal cursor used to determine the depth of the buried gas line. MN36-268 Rev A 10

Section 5: Software Setup with the UtiIityScan DF/HS Configuring the UtilityScan Tablet GSSI s digital antennas are capable of operating with specially prepared Panasonic Toughbook tablet computers. Whether pairing the LineTrac with an UtilityScan DF or UtilityScan HS the operating software is the same. Using the 2D mode of the UtilityScan DF/HS will allow the user to configure the LineTrac settings. Please refer to the UtilityScan DF or HS Quick Start Guide for a comprehensive discussion of all other UtilityScan settings and functionality. Turning on LineTrac: Before changing the collection settings of LineTrac it first must be activated. 1 This is done on the Setup Screen in the Signal Process Menu, where LineTrac is the fourth setting and defaults to Off. 2 Press LineTrac and Power Mode and Frequency Mode will be visible. Power Mode This mode is used to detect AC current flowing through energized electric lines. LineTrac can detect AC current with frequencies of 50 Hz or 60 Hz, the two predominant frequencies of electrical power grids worldwide. 1 Press Power Mode and select 50 or 60 from the menu. 2 Press the check mark button to set the power frequency. The data preview screen will reset and you will see a blue line superimposed on the GPR data. This blue line is the LineTrac data and upon setup will appear quite ragged, with the exception if the UtilityScan system is being setup in very close proximity to a 60 Hz current (not recommended). MN36-268 Rev A 11

Frequency Mode This mode is used to detect the AC current flowing along a conductive utility generated by an AC signal transmitter. LineTrac can detect a wide range of AC signals with 12 industry standard frequencies selectable. 1 Press Frequency Mode and select the frequency to match the signal being generated by the signal transmitter from the menu. 2 Press the check mark button to set the frequency. The data preview screen will reset and you will see a yellow line superimposed on the GPR data. This yellow line is the LineTrac data and upon setup will appear quite ragged, with the exception if the UtilityScan system is being setup in very close proximity to the AC signal transmitter (not recommended). Note: It is possible to collect both Power and Frequency data at the same time, though it can create a cluttered data screen. Data Examples: Power Mode UtilityScan DF/HS Power Mode: Data Set 1-A The above image shows the ragged blue LineTrac data characteristic of no detectable flowing current. What the LineTrac is recording and displaying is the ambient AC signal present in the background. Most GPR data collected with LineTrac will initially look like this. MN36-268 Rev A 12

UtilityScan DF/HS Power Mode: Data Set 1-B The above image is a continuation of the proceeding image, but the UtilityScan system is approaching a buried electric line. The LineTrac data automatically rescaled as a stronger AC current was detected. UtilityScan DF/HS Power Mode: Data Set 1-C The above image is a continuation of the proceeding image and the UtilityScan system has completed traversing the buried electric line. The LineTrac data displays a completed peak with a slight null point at its midpoint and there is a corresponding reflection in the GPR data. MN36-268 Rev A 13

UtilityScan DF/HS Power Mode: Data Set 1-D The UtilityScan s backup cursor function was used to identify the GPR reflector corresponding with the LineTrac data, the horizontal cursor used to determine the depth of the buried electrical line, and the Add Target function was used to insert a color-coded target into the data. UtilityScan DF/HS Power Mode: Data Set 2-A The above image shows data collected crossing a road with overhead power lines on the far side. The LineTrac data has rescaled itself and is beginning to ramp up but the UtilityScan system is still approximately 20 feet from being under the power lines. MN36-268 Rev A 14

UtilityScan DF/HS Power Mode: Data Set 2-B The above image is a continuation of the proceeding image and the UtilityScan system has completed crossing under the overhead lines. A very broad hump is displayed instead of a sharp peak. Data Examples: Frequency Mode UtilityScan DF/HS Frequency Mode: Data Set 1-A The above image shows the ragged yellow LineTrac data characteristic of no detectable tracing frequency. A 33kHz signal has been coupled to a buried natural gas line but the UtilityScan system is still some distance away. Again, most GPR data collected with LineTrac will initially look like this. MN36-268 Rev A 15

UtilityScan DF/HS Frequency Mode: Data Set 1-B The above image is a continuation of the proceeding image, but the UtilityScan system is approaching the buried gas line. The LineTrac data automatically rescaled as a stronger 33 khz signal was detected. UtilityScan DF/HS Frequency Mode: Data Set 1-C The above image is a continuation of the proceeding image and the UtilityScan system has completed traversing the buried gas line. The LineTrac data displays a completed peak with a distinct null point at its midpoint and there is a corresponding reflection in the GPR data. MN36-268 Rev A 16

UtilityScan DF/HS Frequency Mode: Data Set 1-D The UtilityScan s backup cursor function was used to identify the GPR reflector corresponding with the LineTrac data, the horizontal cursor used to determine the depth of the buried gas line, and the Add Target function was used to insert a color-coded target into the data. MN36-268 Rev A 17

Section 6: Software Setup with the UtiIityScan with Built-in LineTrac Configuring the UtilityScan GSSI s UtilityScan is capable of operating with consumer grade and ruggedized tablet computers running the Android operating system. Whichever tablet computer is paired with the UtilityScan, the UtilityScan App software is the same. Using the ScanMax mode of the UtilityScan will allow the user to configure the LineTrac settings. Please refer to the UtilityScan Quick Start Guide for a comprehensive discussion of all other UtilityScan settings and functionality. Turning on LineTrac: Before changing the collection settings of LineTrac it first must be activated. This is done on the Menu Carousel where LineTrac defaults to Off. 1 Press the LineTrac softkey and Power Mode and Frequency Mode will be visible. Power Mode This mode is used to detect AC current flowing through energized electric lines. LineTrac can detect AC current with frequencies of 50 Hz or 60 Hz, the two predominant frequencies of electrical power grids worldwide. 1 Press Power Mode, select 50 or 60 from the menu. Press the check mark button to set the power frequency. 2 The data preview screen will reset, and you will see a green line superimposed on the GPR data. This green line is the LineTrac data and upon setup will appear quite ragged, with the exception if the UtilityScan system is being setup in very close proximity to a 60 Hz current (not recommended). MN36-268 Rev A 18

Frequency Mode This mode is used to detect the AC current flowing along a conductive utility generated by an AC signal transmitter. LineTrac can detect a wide range of AC signals with 9 industry standard frequencies readily selectable or a custom frequency can be entered. 1 Press Frequency Mode, select the frequency to match the signal being generated by the signal transmitter from the menu. 2 Press the check mark button to set the frequency. The data preview screen will reset, and you will see a blue line superimposed on the GPR data. This blue line is the LineTrac data and upon setup will appear quite ragged, with the exception if the UtilityScan system is being setup in very close proximity to the AC signal transmitter (not recommended). Note: It is possible to collect both Power and Frequency data at the same time, though it can create a cluttered data screen. Data Examples: Power Mode UtilityScan Power Mode: Data Set 1-A The above image shows the ragged green LineTrac data characteristic of no detectable flowing current. What the LineTrac is recording and displaying is the ambient AC signal present in the background. Most GPR data collected with LineTrac will initially look like this. MN36-268 Rev A 19

UtilityScan Power Mode: Data Set 1-B The above image is a continuation of the proceeding image, but the UtilityScan system is approaching a buried electric line. The LineTrac data automatically rescaled as a stronger AC current was detected. UtilityScan Power Mode: Data Set 1-C The above image is a continuation of the proceeding image and the UtilityScan system has completed traversing the buried electric line. The LineTrac data displays a completed peak with a slight null point at its midpoint and there is a corresponding reflection in the GPR data. MN36-268 Rev A 20

UtilityScan Power Mode: Data Set 1-D The UtilityScan s backup cursor function was used to identify the GPR reflector corresponding with the LineTrac data, the horizontal cursor used to determine the depth of the buried electrical line, and the Add Target function was used to insert a color-coded target into the data. Data Examples: Frequency Mode UtilityScan Frequency Mode: Data Set 1-A The above image shows the ragged blue LineTrac data characteristic of no detectable tracing frequency. A 33kHz signal has been coupled to a buried natural gas line but the UtilityScan system is still some distance away. Again, most GPR data collected with LineTrac will initially look like this. MN36-268 Rev A 21

UtilityScan Frequency Mode: Data Set 1-B The above image is a continuation of the proceeding image, but the UtilityScan system is approaching the buried gas line. The LineTrac data automatically rescaled as a stronger 33 khz signal was detected. UtilityScan Frequency Mode: Data Set 1-C The above image is a continuation of the proceeding image and the UtilityScan system has completed traversing the buried gas line. The LineTrac data displays a completed peak with a distinct null point at its midpoint and there is a corresponding reflection in the GPR data. MN36-268 Rev A 22

UtilityScan Frequency Mode: Data Set 1-D The UtilityScan s backup cursor function was used to identify the GPR reflector corresponding with the LineTrac data, the horizontal cursor used to determine the depth of the buried gas line, the Add Target function was used to insert a color-coded target into the data. MN36-268 Rev A 23