The Newsletter of Delta Automation Inc.

Similar documents
The Newsletter of Delta Automation Inc.

APPLICATION NOTE. Practical Tips for Using Metalic Time Domain Reflectometers (The EZ Way) What is a Time Domain Reflectometer?

MS2540 Current Loop Receiver with RS485 Communication

Wired Troubleshooting Manual

Preventing Fieldbus Physical Layer Problems

System Troubleshooting for

Getting started with the Time Domain Reflectometer

Modicon Remote I/O Cable System Planning and Installation Guide

System Troubleshooting for

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

MICROMASTER Encoder Module

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Avoiding False Pass or False Fail

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

Copper Cabling Troubleshooting Handbook

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

Advanced Return Path Alignment & Maintenance Using the 9581 SST R4

LINK-MI LM-WHD05B. Wireless HDMI AV Transmission System. User Manual

TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC

Cable guide. for. High Performance Controllers and TeleControllers. Cable types and wiring guidelines

Aqua Turf International, Inc.

V9A01 Solution Specification V0.1

User Manual. Model HCX-11 HDMI Coax Extender. Five-Coax Extender Model HCX-11. Five-Coax Extender Model HCX-11

TC3301. User's Manual

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

XCOM1002JE (8602JE) Optical Receiver Manual

Experiences of CESC in Smart Grid Initiatives LT Network Automation. Anjan Mitra / Arka Ghosh

Snap ShotTM User Manual

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

Warranty Information

CONTENTS. Troubleshooting 1

Power Performance Drill Upgrades. TorqReg. ARDVARC Advanced Rotary Drill Vector Automated Radio Control. Digital Drives Upgrade

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

TC3005(LED/ELED/LASER) User's Manual

Fieldbus Testing with Online Physical Layer Diagnostics

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Carrier-band Network Monitor

Revision 1.2d

The University of Texas at Austin September 30, 2011

Digital Audio Design Validation and Debugging Using PGY-I2C

Scan. This is a sample of the first 15 pages of the Scan chapter.

Cable Broadband Premises Installation and Service

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

3214NXT. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

SyncGen. User s Manual

DMX 512 Language Date: Venerdì, febbraio 12:15:08 CET Topic: Educational Lighting Site

Automation platforms. Modicon Premium Hot Standby Need a spare?

DX-10 tm Digital Interface User s Guide

Siemens Industry Online Support

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

User Manual. HD to Composite Video Downconverter. Model 1360

Bravo AV s Structured or Whole-House Wiring Approach

Lawnbott No Signal /Blackout Troubleshooting Guide

R&S AMU-Z7 Analog I/Q Combiner Technical Information

TEAMS Competition 2014

FiberLink 7142 Series

Limitations of a Load Pull System

VERWER TRAINING AND CONSULTANCY LTD Supporting the PROFIBUS Group UK & PROFIBUS International

Agilent E4430B 1 GHz, E4431B 2 GHz, E4432B 3 GHz, E4433B 4 GHz Measuring Bit Error Rate Using the ESG-D Series RF Signal Generators, Option UN7

PanelView 1400e CRT Maintenance

DESIGN!!GUIDELINES!!!!!

150, MULTI CVIL II Power Train approved. More Than Productivity

DLP600M 6+1 Relay Module for Heating and Cooling Plants

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

Project Summary EPRI Program 1: Power Quality

VTAC HSD ThE NEw STANdARd IN high SpEEd data TESTINg

HDMI Demystified April 2011

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

1 Power Protection and Conditioning

Dynatel Advanced Cable Locator 2250

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

EE028: Practical High Voltage Cable Jointing and Termination

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

EMI/EMC diagnostic and debugging

Cascadable 4-Bit Comparator

Coherence Measurement between two Signals regarding Timing, Phase and Gain Application Note

SONARtrac Technical Bulletin

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

Agilent 87075C Multiport Test Set Product Overview

Coaxial Cable wiring tips and tricks, from BAMF Manufacturing LLC

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

Telesto Private Wire Modem Manual

DLP200M 2 Relay Module for Heating and Cooling Plants

EE201: Transmission Line Protection

User Manual. Model 1351 DVI Repeater with HDCP

384A Adapter Installation Instructions

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

Technical Support HOME THEATER. VGA over Cat5e/ Cat6 Extenders with Audio

User Manual SP8SDI. SD/HD/3G-SDI 1 to 8 Distribution. Amplifier & Repeater. All Rights Reserved Version: SP8SDI _2017V1.1

Tools to Debug Dead Boards

THE NEW STANDARD IN HIGH SPEED DATA TESTING

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

ITEM NO.: CD102, CD104, CD108, CD408, CD816, CD116, CD1664, CD102A, CD408A, CD816A, CD1632A, CA101, CA101A, CA404, CA101VH

Transcription:

VOL 3 ISSUE 10 Summer 2004 The Newsletter of Delta Automation Inc. Electrical Storms and effects on Modbus Plus Systems A brief explanation Of TDR operation Modicon Trivia Question TWO WINNERS!! Correctly answered last Issue s Trivia question. Important VFD Grounding issues Contact names, numbers and E-mail addresses

Summer Storms and Modbus Plus Systems During the Summer months, especially in the southern states, late evening thunderstorms are an almost everyday occurrence. The violent lightning that typically accompanies these storms is a very real and sometimes destructive threat to communication systems. Very recently, Delta Automation engineers were dispatched on an emergency basis to troubleshoot and repair several of these systems disrupted by lightning. One such Modbus Plus system went down during a severe storm around midnight. The plant technicians began troubleshooting, and determined that the network was down and only a few of the nodes were communicating. They continued troubleshooting throughout the night and when the plant Engineers arrived the next morning, they placed a call for assistance to Delta Automation, Inc. Two engineers with test equipment were dispatched and arrived on-site within hours. As with most Modbus Plus systems, this system was an undocumented as built system. Luckily, the plant technicians knew where all of the various nodes were located. The test equipment was connected and immediately, an open circuit was discovered, this was repaired, and another was found, this repeated itself three more times, when a short was found. These opens and the short were caused by the process of inspecting and moving the various components of the system during troubleshooting. Once these faults were found and rectified, it was noticed that the overall system impedance was too low. A slight short was detected by the TDR several hundred feet away. This was investigated and was found to be an improperly set termination switch on an older model Phoenix tap (See Deltas Fall 2002 newsletter describing just such a possibility). The switch was repositioned to the correct setting. The TDR still indicated another of the same type of discontinuity farther down the line. This was again found to be a termination switch in the wrong position. Once this was corrected, the system was put back into service. Ultimately, no lightning damage of any kind was found. All of the faults were man made. Apparently, the chain of events is thought to have been something like this: during the storm, a voltage surge disturbed the Modbus Plus communications possibly by shutting down one or more of the nodes. This could cause a lockup of the Modbus Plus processor on the affected card. (A power cycle would typically restore the communications.) With a loss of communications reported, the network itself was suspected. This system was out of operation for almost 8 hours. Some of the issues located and repaired, would be very difficult to locate in a timely and efficient manor without use of the proper test equipment that Delta engineers are proficient on. Delta Automation, Inc has emergency on call service, 24 hours a day. There is no extra charge for emergency service, and unless on weekends or holidays, no overtime is charged.

How a Time Domain Reflectometer (TDR) works A TDR is a piece of test equipment designed to analyze and troubleshoot metallic cable systems. The TDR will display any discontinuities found along a given piece of cable. These discontinuities may be either shorts, opens, or somewhere in between. In order to get an accurate distance measurement to the discontinuity, it is necessary to setup the test equipment to match a certain parameter of the cable, provided by the manufacturer s specification sheets. For purposes of this discussion, the most important is the velocity of propagation or VP. It is usually represented as a percentage of the speed of light. For example, if the VP is.82, this means that the speed of the signal along this particular piece of copper travels at approximately 82% of the speed of light. This is sometimes referred to as the speed of the cable. Using built in algorithms along with the setup information entered, the distance to an incident can then be calculated and displayed. The TDR sends out a radar like signal along the cable under test and measures the time it takes to get a reflection of an incident, such as an open. The TDR compares the speed of a signal traveling down a wire (VP) to the speed of light. This speed of light in a vacuum (300 million meters per second or 186,000 miles per second) is the standard by which all these signals are measured. VP between cables gives you some idea of which cables perform better at higher frequencies. A faster velocity means less frequency loss and flatter frequency response overall. In utilizing a TDR, you must be familiar with transmission line theory in order to interpret the displayed results. For example, in a perfect world, all power transmitted down a line is all absorbed by the end of line terminator. We all know that in practice the termination resister is not perfectly matched to the line and some impedance mismatch occurs. This causes some of the signal to be reflected back. On the TDR this is indicated as a discontinuity. By contrast, a complete open will reflect ALL of the signal back along the line. This too will be indicated by the TDR, however it will be a much larger graphic representation. A TDR is not a magical instrument that will immediately locate and tell you where a fault is. The displayed results are a graphic representation of anything along the line which disrupts the base line impedance, such as 75 Ohms and must be properly interpreted. Anything greater than, for instance, 75 Ohms, is indicated by a vertical rise in the graph. A short, by contrast, is indicated by a vertical drop in the graph. Everything else is somewhere in between, tap, splitters, splices and of course cable faults, fall into this category. It takes an experienced operator to determine whether any given disturbance displayed is a problem or not. Delta Automations engineers have years of experience using these instruments and are highly skilled at locating faults with the types of communication systems utilized in control networks. Examples of some of these types of networks are: Modicon remote I/O, Modicon Modbus Plus, Modicon Modbus II, Symax Blue Hose, Siemans Profibus, A/B blue hose, and A/B Data highway plus. Most any metallic type cable system can be tested using a TDR, given the proper VP. Even in instances where it is not available from a publication, it can be calculated on-site with great accuracy.

Modicon Trivia Question TWO WINNERS!!!!! There were two correct answers to the identity of this product. It is an address pack for the original version of the J810 I/O adapter between the 584 controller and 800 series I/O. In the final models, the switches were moved on-board. The two winners were: Darin Fox of Graybar, Richmond, and Mike Mellish formerly of Schneider Electric Both will receive a dinner certificate from Applebees restaurant. Diskette for size Comparison only E-MAIL: PLC@DELTAAUTOMATION.COM ModLink as a Troubleshooting Tool Modlink as a Troubleshooting/Maintenance Tool Savvy maintenance technicians have discovered that using software programs as aids in troubleshooting PLC problems greatly reduces the time to locate the problem. Modlink can connect to the PLC using Modbus, Modbus Plus, or TCPIP depending on the hardware available. Requested data from inputs, outputs, input registers, or output registers can then be linked to an Excel spreadsheet for monitoring. Conditional states of the data can then change color for visual recognition. Modlink files with their respective Excel spreadsheet can be saved for future use for a peculiar problem. This is a cheap and effective troubleshooting method for maintenance personnel. This software can also be utilized as a poor man s HMI. It can report values and data with the visual indicators available in Excel.

Important VFD Grounding Issues Recently, a large user of Square D Altivar drives began experiencing nuisance trips of various types on several large (150 HP) drives. The user had exchanged the drives with their spare, replaced it with another from the manufacturer and tried various other fixes. Delta Automation, Inc. was called in to investigate the problem. As in most cases, intermittent problems rarely show up when you want them to. The Delta Engineer, while on-site waiting to witness the failure, began evaluating the installation. These drives have been in service for several years with no problems. Plant personnel stated that no changes had been made to either of these systems. Upon further examination, by the Delta Engineer, it was discovered that several new smaller drives had been installed nearby on unrelated machinery. The grounds for these drives however, were tied to the ground bus of the larger drives in question, rather than continuing back to the MCC. These grounds were re-routed to the MCC and no further problems were experienced. 804-236-2800 Toll free 1-888-PC-DELTA fax 804-236-2900 (888-723-3582) Bob Culley President bobculley@deltaautomation.com Margarete Culley Vice President mculley@deltaautomation.com Roy Caudle Service roycaudle@deltaautomation.com Bernie Wieland Sales berniewieland@deltaautomation.com Clark Jones Sales clarkjones@deltaautomation.com Vann Barden Outside Sales vannbarden@deltaautomation.com Mike Martinelli Repair marti@deltaautomation.com Theresa Umbel Accounting plc@deltaautomation.com For after hours Emergency Service or Parts Call our main number 888-723-3582 Extension 55 Leave a message and someone will respond within fifteen minutes to answer your call. www.deltaautomation.com 2704 Charles City Road Richmond, VA. 23231