Model KT 170 Cooling incubators with thermoelectric cooling

Similar documents
Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KT 53 Cooling incubators with thermoelectric cooling

Model KBF 720 Constant climate chambers with large temperature / humidity range

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Forced Convection Laboratory Ovens

Magnetic Stirrers Magnetic Stirr

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

Label Applicator HERMA 400

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Sensor technologies Proximity sensors Series ST4. Brochure

7.5ft Outdoor Double-Sided Interactive LCD Sign, Transit Center Kiosk Model: NISDK-550PCT, 55 Double-Sided

COMBINATION UNITS MARCH 2018

Vortex Mixers. Mini Vortex Mixers Heavy-Duty Vortex Mixers Microplate Vortex Mixers Multi-Tube Vortex Mixers. Asia Pacific

LCD Display Wall Narrow Bezel Series

Process Transmitter RMA 422

April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION

IMPAC Infrared Thermometers

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

Frequency Converter Fv

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

LCD Display Wall Narrow Bezel Series

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

120cm (4x36 Watt) incl. Splitter Instruction Manual

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

CTC Series. Compact Temperature Calibrator

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Product Data Sheet 4650 N-465

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

XPert Filtered Balance Systems

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Process transmitter RMA422

Dissolved Oxygen Transmitter

NetterVibration. Netter Electric External Vibrators Series NEG. Serving industry with vibration

PTC Series. Professional Temperature Calibrator PTC-155/350/425/660

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

Series 3000 Dual Cast Transmitter

IKA Analytical line Calorimeters C 2000

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

S N A C K S D R I N K S. for the sale of confectionery/snacks and bottled and canned drinks RANGE

UNIGAS Hand-held combustion gas analyzer with 3 sensors

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Programat P310. Economical firing performance. Top-quality results. The user-friendly furnace. Now with new OSD display

SMG_GB_ :55 Uhr Seite 1 C M Y CM MY CY CMY K Shakers and Mixers Probedruck

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 331i / DMP 333i LMP 331 i

Product Data Sheet 8506 VW-691

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

X-ray inspection system Dymond

An impressive appearance

Product Data Sheet 4656 EZ

ULTRALOW TEMPERATURE FREEZERS -86 C

Sigma 4-16S Sigma 4-16KS Sigma 4-16KHS

POWER MOLE SERIES DA GAO RGBT RADIX

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Agilent 87075C Multiport Test Set Product Overview

STERILISATION Simple solutions made to measure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Global Trade Medical Supplies

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Up to 85% higher Service Life due to efficient sealing method.

Panel-mounting thermostats, type series EM

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Roof-mounted Blue e+ cooling unit Integration solution VX25

TROJANUVTORRENTTM. Drinking Water Disinfection

SIMATRIX NEO V2 Modular Video Matrix

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Manual. Simrad IS80 Wind Instrument WI80. English

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Dissolved Oxygen Transmitter

Safe Enclosure Cooling

ETC Quick Guide. Source Four LED Profile

Lt DELTA USA, Inc

Orbit TM DIGITAL SHAKERS

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Transcription:

Model KT 170 Cooling incubators with thermoelectric cooling BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C Energy efficient, environmentally friendly and secure MAIN FEATURES Temperature range: 4 C to 100 C APT.line preheating chamber technology Adjustable fan speed Electric cooling with Peltier module Controller with time-segment and real-time programming Display via LCD monitor Input via pushbutton/rotary knob Inner door made of tempered safety glass 2 stainless steel racks Stackable with KT 115 Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm Computer interface: Ethernet Data recording and USB interface ORDERING INFORMATION Interior volume [L] Voltage Option model Version Art.-No. Model KT 170 163 200 240 V 1~ 50/60 Hz Standard KT170-230V 9020-0289 100 120 V 1~ 50/60 Hz Standard KT170UL-120V 9020-0310 TECHNICAL DATA Description KT170-230V KT170UL-120V Article Number 9020-0289 9020-0310 Performance Data Temperature Temperature range [ C] 4 100 4 100 Temperature variation at 37 C [± K] 0.4 0.4 Temperature fluctuation [± K] 0.1 0.1 Max. heat compensation at 40 C [W] 100 100 Recovery time after 30 seconds door open 90 aperture angle at 37 C [min] 3 3 Electrical data Rated Voltage [V] 200 240 100 120 Page 1 / 5

Description KT170-230V KT170UL-120V Article Number 9020-0289 9020-0310 Power frequency [Hz] 50/60 50/60 Nominal power [kw] 0.8 0.8 Unit fuse [A] 10 10 Phase (Nominal voltage) 1~ 1~ Measures - Outer dimensions Width net [mm] 860 860 Height net [mm] 1025 1025 Depth net [mm] 655 655 Wall clearance back [mm] 100 100 Wall clearance sidewise [mm] 240 240 Measures - Doors Inner doors 1 1 Unit doors 1 1 Measures - Internal Dimensions Width [mm] 600 600 Height [mm] 765 765 Depth [mm] 355 355 Measures Interior volume [L] 163 163 Net weight of the unit (empty) [kg] 102 102 permitted load [kg] 120 120 Load per rack [kg] 30 30 Environment-specific data Energy consumption at 25 C 80 Wh/h 80 Wh/h Energy consumption at 37 C 80 Wh/h 80 Wh/h Sound-pressure level [db(a)] 48 48 Fixtures Number of shelves (standard/maximum) 2/10 2/10 OPTIONS AND ACCESSORIES 10 mm, left 01 8012-0393 10 mm, right 01 8012-0392 10 mm, top 01 8012-0391 30 mm, left 01 8012-0047 Access port with silicone plug Alarm output, zerovoltage Analog output, 4 20 ma Calibration certificate, expanded 30 mm, right 01 8012-0046 30 mm, top 01 8012-0045 50 mm, left 01 8012-0051 50 mm, right 01 8012-0050 50 mm, top 01 8012-0049 100 mm, top 01, 10 8012-0053 for temperature (±2 C), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal that can be switched off 8012-1002 for temperature values (output not adjustable) 02 8012-0996 for temperature; for extending the measurement in center of chamber to include another test temperature 8012-0022 Page 2 / 5

Calibration certificate, temperature for temperature, measurement in center of chamber at specified temperature 8012-0030 temperature measurement incl. certificate and 27 at specified temperature 8012-0921 temperature measurement incl. certificate, 15-18 at specified temperature 8012-0918 temperature measurement incl. certificate, 9 at specified temperature 8012-0915 Cart Cart stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm 9051-0018 Class 3.3 independent temperature safety device Data Logger Kit Data Logger Software Door heating with visual alarm (DIN 12880) 8012-1000 T 220: For continuous temperature logging from -90 C to 220 C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) 19 8012-0715 19 8012-0821 120 V option model 8012-0927 230 V option model 8012-0926 Door lock lockable door handle 8012-1025 Interface converter Interface converter, USB / RS422 Interior lighting Interior socket RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0557 230 V, 50/60 Hz option model 8012-0556 RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0405 230 V, 50/60 Hz option model 8012-0380 RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) with 15 W light bulb 8012-0665 120 V option model 8012-0932 230 V option model 8012-0933 waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, coverable, with corresponding plug (nominal voltage; max. 500 W; max. 90 C; protection class IP67) Magnetic Pouch (A4) insert pouch with magnetic strip 07 8012-1006 1007-0098 1007-0065 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 Pt 100 temperature sensor additional flexible Pt 100, interior, for displaying the temperature on the unit display 8012-0994 Rack stainless steel 6004-0112 Rack accessories Rack accessories fasteners (1 set of 4) for additional security of racks 8012-0620 Rack, reinforced stainless steel, with 1 set of 4 fasteners, max. load 70 kg 8012-0828 RS 422 interface RS 422 interface, cable (15 m) RS 422 interface, cable (50 m) in place of Ethernet, for communication software 8012-1004 modular plug distributor for 10 RS 422 interfaces 8012-0295 RS 422 connection cable (15 m) between plug distributor and RS 422 interface 5023-0036 RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor 5023-0117 Rubber pads set of 4 anti-slip feet, for safe stacking of unit 10 8012-0001 Shelf, perforated stainless steel 6004-0115 Shelf, reinforced positioned at bottom level, max. load 67 kg, with additional attachment for operation of shaking device, stirring device or roller bottle system 8012-0817 Page 3 / 5

APT-COM communications software version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 Software version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 Zero voltage relay contacts for controlling 3 relay contacts via program-pin DIN socket (max. 24 V regulators, accessible via 6-2.5 A) 8012-0998 SERVICES Installation services Installation and set up of unit at operating location, connect to existing connections 13, 18 DL100300 Instruction unit function instructions for operation and programming of the controller 18 DL100700 Preventive maintenance Preventive maintenance Execution of equipment inspection according to maintenance plan 14, 18 DL200400 Calibration services Calibration temperature including certificate, one measuring point in center of chamber at specified temperature DL300101 Temperature measurement 18 including certificate, 18 at specified temperature DL300118 Temperature measurement 27 including certificate, 27 at specified temperature DL300127 Temperature measurement 9 including certificate, 9 at specified temperature DL300109 Validation services Execution of IQ/OQ in accordance with qualification folder 15, 18, 20 DL410200 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL440500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0874 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0961 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL030041 beginning with the date of delivery, wearing parts are not included DL030042 Page 4 / 5

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract (see the chapter on BINDER Service) to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for both items. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. BINDER GmbH Tuttlingen, Germany TEL +49 7462 2005 0 FAX +49 7462 2005 100 info@binder-world.com BINDER Asia Pacific (Hong Kong) Ltd. Kowloon, Hong Kong, P.R. China TEL +852 39070500 FAX +852 39070507 asia@binder-world.com Representative Office for CIS Moscow, Russia TEL +7 495 988 15 16 FAX +7 495 988 15 17 russia@binder-world.com www.binder-world.ru BINDER Environmental Testing Equipment (Shanghai) Co., Ltd. Shangha, P.R. China TEL +86 21 685 808 25 FAX +86 21 685 808 29 china@binder-world.com BINDER Inc. Bohemia, NY, USA TEL +1 631 224 4340 FAX +1 631 224 4354 usa@binder-world.com www.binder-world.us Page 5 / 5