Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Similar documents
Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 170 Cooling incubators with thermoelectric cooling

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Model KBF 720 Constant climate chambers with large temperature / humidity range

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Forced Convection Laboratory Ovens

Label Applicator HERMA 400

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

Magnetic Stirrers Magnetic Stirr

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

Product Data Sheet 4650 N-465

April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Process Transmitter RMA 422

ULTRALOW TEMPERATURE FREEZERS -86 C

DMP 331i / DMP 333i LMP 331 i

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Product Data Sheet 8506 VW-691

Roof-mounted Blue e+ cooling unit Integration solution VX25

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

XPert Filtered Balance Systems

SIMATRIX NEO V2 Modular Video Matrix

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

Dissolved Oxygen Transmitter

120cm (4x36 Watt) incl. Splitter Instruction Manual

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

7.5ft Outdoor Double-Sided Interactive LCD Sign, Transit Center Kiosk Model: NISDK-550PCT, 55 Double-Sided

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

IKA Analytical line Calorimeters C 2000

Section C Recorders. DPR mm Digital Strip Chart Recorder

Up to 85% higher Service Life due to efficient sealing method.

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Panel-mounting thermostats, type series EM

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

Frequency Converter Fv

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Orbit TM DIGITAL SHAKERS

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Vortex Mixers. Mini Vortex Mixers Heavy-Duty Vortex Mixers Microplate Vortex Mixers Multi-Tube Vortex Mixers. Asia Pacific

Features. Specifications. Finish. Notes

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Hybrid Chart Recorder 250 mm (10")

Manual. Simrad IS80 Wind Instrument WI80. English

Sensor technologies Proximity sensors Series ST4. Brochure

Dissolved Oxygen Transmitter

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Optical Cryostat - Omniplex TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Gamma instabus. Technical product information

POWER MOLE SERIES DA GAO RGBT RADIX

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

LD OEM/LD PDS/LD PeCo

Product Data Sheet 4656 EZ

Product Data Sheet 4656 ZW

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

CTC Series. Compact Temperature Calibrator

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage

UNIGAS Hand-held combustion gas analyzer with 3 sensors

COMBINATION UNITS MARCH 2018

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Cooling systems for ORBIMAT

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

LUNERA SERIES L7 _ GEN 3

ABB i-bus EIB Universal dimmer 6155 EB for Installation

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Electrical connection

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

PTC Series. Professional Temperature Calibrator PTC-155/350/425/660

SonoruS Audio. ATR10 Analog Tape Reproducer. Operating Manual

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage

Global Trade Medical Supplies

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

LED Spot 300W. Please read this user manual before your operation

Panel-Mounted Thermostat

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Tube Roller Shakers. User Guide. Version 1.2

SAL Series Wireless Clock (V1)

Transcription:

Model KT 53 Refrigerated incubators with thermoelectric refrigeration The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The refrigerated incubators of the KT series are state-of-the-art in application and protect the samples. BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C Energy efficient, environmentally friendly and secure MAIN FEATURES Model 53 Temperature range: 4 C to 100 C APT.line preheating chamber technology Adjustable fan speed Electric refrigeration with Peltier module Controller with time-segment and real-time programming Display via LCD monitor Input via pushbutton/rotary knob Inner door made of tempered safety glass 2 stainless steel racks Units up to 115 liters are stackable Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm Computer interface: Ethernet Data recording and USB interface ORDERING INFORMATION Interior volume [cu.ft.] Voltage Option model Version Art.-No. Model KT 53 1.9 200 240 V 1~ 50/60 Hz Standard KT053-230V 9020-0311 100 120 V 1~ 50/60 Hz Standard KT053UL-120V 9020-0312 Page 1 / 5

TECHNICAL DATA Description KT053-230V 1 KT053UL-120V 1 Article Number 9020-0311 9020-0312 Performance Data Temperature Temperature range [ C] 4 100 4 100 Temperature variation at 37 C [± K] 0.3 0.3 Temperature fluctuation [± K] 0.1 0.1 Max. heat compensation at 37 C [W] 100 100 Recovery time after 30 seconds door open at 37 C [min] 2 2 Electrical data Rated Voltage [V] 200 240 100 120 Power frequency [Hz] 50/60 50/60 Nominal power [kw] 0.4 0.4 Unit fuse [A] 10 10 Phase (Nominal voltage) 1~ 1~ Outer dimensions Width net [in] 26 26 Height net [in] 25.02 25.02 Depth net [in] 24.82 24.82 Wall clearance back [in] 3.94 3.94 Wall clearance sidewise [in] 9.46 9.46 Doors Inner doors 1 1 Unit doors 1 1 Internal Dimensions Width [in] 15.76 15.76 Height [in] 15.76 15.76 Depth [in] 13.16 13.16 Measures Interior volume [cu.ft.] 1.9 1.9 Net weight of the unit (empty) [lbs] 139 139 permitted load [lbs] 88 88 Load per rack [lbs] 33 33 Environment-specific data Energy consumption at 25 C [Wh/h] 75 75 Energy consumption at 37 C [Wh/h] 75 75 Sound-pressure level [db(a)] 48 48 Fixtures Number of shelves (std./max.) 2/5 2/5 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. DIMENSIONS INCL. FITTINGS AND CONNECTIONS [MM] Page 2 / 5

OPTIONS AND ACCESSORIES Access port with silicone plug Alarm output, zerovoltage left 10 mm 01 8012-1290 30 mm 01 8012-1158 50 mm 01 8012-1165 right top 10 mm 01 8012-1289 30 mm 01 8012-1155 50 mm 01 8012-1163 10 mm 01 8012-1288 30 mm 01 8012-1152 50 mm 01 8012-1161 100 mm 01, 10 8012-1168 for temperature (±2 C), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal that can be switched off 8012-0982 Analog output 4-20 ma for temperature values (output not adjustable) 02 8012-0974 Calibration certificate, expanded Calibration certificate, temperature for temperature; for extending the measurement in center of chamber to include another test temperature 8012-1122 for temperature, measurement in center of chamber at specified temperature 8012-1141 temperature measurement incl. certificate and 27 at specified temperature 8012-1600 temperature measurement incl. certificate, 15-18 at specified temperature 8012-1579 temperature measurement incl. certificate, 9 at specified temperature 8012-1558 Cart Cart stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm 9051-0018 Class 3.3 independent temperature safety device Data Logger Kit Data Logger Software Door heating with visual alarm (DIN 12880) 8012-0978 T 220: For continuous temperature logging from -90 C to 220 C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) 19 8012-0715 19 8012-0821 120 V option model 8012-0930 230 V option model 8012-0931 Door lock lockable door handle 8012-1668 Interface converter Interface converter, USB / RS422 Interior lighting Interior socket LED light bars RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0557 230 V, 50/60 Hz option model 8012-0556 RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0405 230 V, 50/60 Hz option model 8012-0380 RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) with 15 W light bulb 8012-0665 120 V option model 8012-0932 230 V option model 8012-0933 Waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, with cover and corresponding plug (nominal voltage; max. 500 W; max. 90 C; protection class IP67) Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz 07 8012-0984 Basic set 300, length 30 cm 8012-1107 Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars Expansion set 300, length 30 cm 8012-1716 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 Page 3 / 5

Pt 100 temperature sensor additional flexible Pt 100, interior, for displaying the temperature on the unit display 8012-0935 Rack accessories Rack accessories fasteners (1 set of 4) for additional security of racks 8012-0620 Rack, reinforced stainless steel, with fasteners (1 set of 4), max. load 70 kg 8012-0829 Racks stainless steel 6004-0007 RS 422 interface in place of Ethernet, for communication software 8012-0983 RS 422 interface, accessories modular plug distributor for 10 RS 422 interfaces 8012-0295 RS 422 connection cable (15 m) between plug distributor and RS 422 interface 5023-0036 RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor 5023-0117 Rubber pads set of 4 anti-slip feet, for safe stacking of unit 10 8012-0001 Shelf, perforated Stainless steel 6004-0029 Shelf, reinforced positioned at bottom level, max. load 67 kg, with additional attachment for operation of shaking device, stirring device or roller bottle system APT-COM communications software 8012-0818 version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 Software version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 Zero voltage relay contacts for controlling 3 relay contacts via program regulators, accessible via 6-pin DIN socket (max. 24 V - 2.5 A) 8012-0976 SERVICES Installation services Installation and set up of unit at operating location, connect to existing connections 13, 18 DL10-0300 Instruction unit function instructions for operation and programming of the controller 18 DL10-0700 Preventive maintenance Preventive maintenance Executive of equipment inspection according to maintenance plan 14, 18 DL20-0400 Calibration services Calibration temperature incl. certificate including certificate, one measuring point in center of chamber at specified temperature DL30-0101 Temperature measurement 18 including certificate, 18 at specified temperature DL30-0118 Temperature measurement 27 including certificate, 27 at specified temperature DL30-0127 Temperature measurement 9 including certificate, 9 at specified temperature DL30-0109 Validation services Execution of IQ/OQ in accordance with qualification folder 15, 18, 20 DL41-0200 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL44-0500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0874 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0961 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL03-0041 beginning with the date of delivery, wearing parts are not included DL03-0042 Page 4 / 5

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ folder. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. Page 5 / 5