CATHODE CURRENT DISTRIBUTION CONTROL DEVICE

Similar documents
Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Lt DELTA USA, Inc

3B SCIENTIFIC PHYSICS

SM-10 SAT Level Meter User s Manual

TUC: Universal thermostat

Photoelectric Sensors E3F2

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

Azatrax Model Railroad Track Signal Control - Single Track

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Remote Voltage Detector - JET (RVD) Medium and High Voltage kV AC

General Specifications

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

LABSONIC M The ultrasonic homogenizer for every application. Benefits

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

TOSHIBA Industrial Magnetron E3328

.Power Distribution Center. PD-1. Instruction Manual

Single Point Flow Monitor SW118 SW119

Ordering details. Approval. Classification

IDsn ODsn Series Product Manual

Flat-Bed Module Recorders

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Flygt Submersible Motor Cables

Safety Light Curtain Orion1 Extended

Heating thermostat Series AMHs B Operating Instructions 11.06/

User Manual. SWIT ELECTRONICS CO., LTD Model: S-4904P Wireless HD Transmission System(with Panel Receiver) Ver:A

Electrical connection

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

INSTRUCTION MANUAL LITE-WRITE LASER SHOW TM

ZIG-POC-100. HDBaseT HDMI Extender

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

Telemetry Receiver Installation Guide

Description Diagram Page

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

AGS Low profile capacitive air gap measuring sensor for rotating machines

Installation Guide VL-MV10. Model No.

EGM Einthoven Goldberger Module Type 701

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

SonoruS Audio. ATR10 Analog Tape Reproducer. Operating Manual

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Figure 1: Device components

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Panel-mounting thermostats, type series EM

UltraTwist. Product Description. Instruction Guide

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Modular Lube Lubrication Systems System Controls

SQM40/41 Actuators for air and gas dampers

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Multifunction Digital Timer

Features. = +25 C, IF = 1 GHz, LO = +13 dbm*

Panel-Mounted Thermostat

WQ Series Water Quality Bench top Meters

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

User's Guide to the PROLITE-30B

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

INSTRUCTION MANUAL MUSICAL LASER LIGHT SHOW TM

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Emergency lighting units EM powerled

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Ps Token Code Automatic parking facilities Description with transponder token

Label Applicator HERMA 400

UNIGAS Hand-held combustion gas analyzer with 3 sensors

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

Datasheet - SRB301LC 24VAC/DC

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

R&S RT-Zxx High-Voltage and Current Probes Specifications

LED bar- Built-in constant current - 105Lm/W-thin 5.5mm-waterproof

Business Display Solutions - Institutional Television Mirror TV. Installation Guide for 32PM8822 ( BDL3221M) 42PM8822 (BDL4221M)

STX Stairs lighting controller.

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

Operating instructions III / 2004

Light Source. Specification & User Manual

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Emergency lighting units EM powerled

ACUBRITE 23 SS. Manual. Stainless Steel Chassis 23" LCD Display. Content

10 SERIES. Light dependent relays A

SAUTER flexotron RDT405 Manual

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

PLL1920M LED LCD Monitor

Surface-mounting thermostat, type series ATH.-SE to monitor seagoing vessel equipment

Electrical connection

Bimetal Temperature Switch

Transcription:

CATHODE CURRENT DISTRIBUTION CONTROL DEVICE INSTRUCTION MANUAL - REV 0 - ELECTRONIQUE INDUSTRIELLE ZI François Horteur - 73660 SAINT REMY DE MAURIENNE - FRANCE Tel : (33) 4 79 64 14 44 - Fax : (33) 4 79 64 47 97 E-mail : info@serem-electronics.com SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 0/13

CONTENTS CATHODE CURRENT DISTRIBUTION CONTROL DEVICE Page 2: Function Composition of the device Remarks concerning use CATHODE CURRENT DISTRIBUTION CONTROL CANE (CCRC) Page 3: Page 4: Characteristics of the CCRC Presentation of the CCRC INDICATOR FOR CATHODE CURRENT DISTRIBUTION CONTROL CANE (IN-CCRC) Page 5: Page 6: Characteristics of the IN-CCRC Presentation of the IN-CCRC TEST BENCH FOR CATHODE CURRENT DISTRIBUTION CONTROL CANE (BT-CCRC) Page 7: Page 8: Characteristics of the BT-CCRC Presentation of the BT-CCRC OPERATING PROCEDURE Page 9: Page 10: Page 11: Personnel required Specific risks linked to operation When should the measurement be taken? Checking the device Zero adjust control Full scale adjustment Test on the pot Test operation Remark 1: cane position on cathode bar Remark 2: precautions for using the device Page 12: ATTACHMENT 1 Diagram describing the checking of the CCRC cane on the test bench Page 13: List of spare parts and accessories. SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 1/13

CATHODE CURRENT DISTRIBUTION CONTROL DEVICE FUNCTION This equipment can distinguish between three types of cathode bar on a given pot: Those with rated current flowing through them Those with half the rated current flowing through them Those with no current flowing through them at all (cut bars) COMPOSITION OF THE DEVICE The device consists of: A measurement probe with Hall effect sensors: CATHODE CURRENT DISTRIBUTION CONTROL CANE - CCRC A digital-display measurement indicator: INDICATOR FOR CATHODE CURRENT DISTRIBUTION CONTROL CANE - IN-CCRC A test bench: TEST BENCH FOR CATHODE CURRENT DISTRIBUTION CONTROL CANE - BT-CCRC REMARKS CONCERNING USE This device is a measuring instrument; although it has been designed to withstand harsh measurement conditions (industrial context, high temperatures, measurement points accessible with difficulty, risks of electric shock), it must be handled with care. The measurement probe (CCRC cane) is long and thin. It is made of materials that react in different ways to temperature stresses (aluminium and epoxy), so it is important to respect the following instructions: Avoid twisting and bending it while passing it through the grating. Avoid leaving the cane immobile on the cathode bar for too long, since this causes it to become very hot and there is a risk of it being damaged. Cool the jumper (bottom part) with compressed air after having taken measurements on half a pot. Check the general condition of the probe frequently. SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 2/13

CATHODE CURRENT DISTRIBUTION CONTROL CANE CCRC MODEL: FUNCTION: Cane CCRC type Used in conjunction with an IN-CCRC type indicator, this cane measures the magnetic field generated by direct current flowing through a cathode bar, operating from the gap between pots, through the grating. CHARACTERISTICS: Nylon handle. Epoxy tube. Aluminium jumper and lamp holder. Push button on handle to activate lighting. Push-pull connector for the digital indicator (IN-CCRC). Lamps to light up the measurement area (6 V 0.2 A). Electrical insulation between top part and bottom part: > 5 kv. Instantaneous maximum temperature of use (at the bottom part): 300 C. Ambient temperature of use: 100 C. Max. thickness (tube and bottom part): 30 mm. Dimensions: 2060 x 160 x 32 mm. Weight: 2.1 kg. Remarks: This cane is a measuring instrument and must be handled with care. To use it properly, it is important to respect the following instructions: Avoid twisting it while passing it through the grating. Avoid leaving the cane immobile on the cathode bar for too long, since this causes it to become very hot and there is a risk of it being damaged. Cool it with compressed air after having taken measurements on a half-pot Check the general condition of the probe frequently SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 3/13

CATHODE CURRENT DISTRIBUTION CONTROL CANE CCRC 55cm Diam. 32 mm 206cm Diam 30 mm 9cm 11cm CRCN3A 10cm 16cm SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 4/13

INDICATOR FOR CATHODE CURRENT DISTRIBUTION CONTROL CANE IN-CCRC MODEL: FUNCTION: Digital indicator - IN-CCRC type Connected with a CCRC type cane, this indicator is used to control cathode current distribution (measurement of magnetic fields up to 200 Gauss). CHARACTERISTICS: Operating range: Display: 0 to 200.0 Gauss 3 1/2 digits, LCD, height: 14 mm, back-lighting possible Indicator precision: ± 0.1% Temperature stability: Zero adjust control: 100 ppm/ C by externally accessible potentiometer. Full scale adjustment: by externally accessible potentiometer Power supply: Push buttons: Operation indicators: Unit: by Ni-Cd 6V/2, 4Ah storage battery, allowing over 8 hours of autonomous operation. ON to switch the device on (it switches off automatically) SIDE to display the Long Side or Short Side measurement red light-emitting diodes. black ABS, with carrying strap Dimensions: (H x W x D): 75 x 148 x 195 Weight: 1 kg Remarks: Accessories supplied with the IN-CCRC: 1 IN/CCRC connector cable (0.3 kg) 1 battery charger (0.4 Kg) To ensure that the cane lighting functions correctly, do not forget to charge up the indicator. The "TEMP" indicator lights up when the cane temperature is too high. If this happens, stop the measurements, remove the probe from the conductor and leave it to cool down until the indicator goes out. If these instructions are not respected, there is a risk of the measurement sensors and cane structure being damaged. SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 5/13

INDICATOR FOR CATHODE CURRENT DISTRIBUTION CONTROL CANE IN-CCRC SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 6/13

TEST BENCH FOR CATHODE CURRENT DISTRIBUTION CANE BT-CCRC MODEL: FUNCTION: Test bench type BT-CCRC This device is used to test the functioning of the CCRC cane and IN-CCRC indicator assembly. CHARACTERISTICS: 2 test chambers (150 gauss). Black ABS frame. Toggle switch. Test chamber power supply push button (3 min. time delay) Red test chamber power supply indicator Auxiliary power supply: 120 or 230 V AC. (-15/+10%), 30 VA max. Dimensions (WxDxH): 265 x 265 x 113 mm. Weight: 5.1 kg. SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 7/13

TEST BENCH FOR CATHODE CURRENT DISTRIBUTION CANE BT-CCRC SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 8/13

OPERATING PROCEDURE PERSONNEL REQUIRED 2 operators. SPECIFIC RISKS LINKED TO OPERATION No specific risk linked to operation. WHEN SHOULD THE MEASUREMENT BE TAKEN? The current must be stable. When no other operations are being performed on the pot being measured (for safety reasons). CHECKING THE DEVICE Before going to the potline, check that the device is working correctly. Connect the digital indicator (IN-CCRC) to the cathode current distribution control cane (CCRC) using the connector cable. Position the CCRC stirrup in the two test bench chambers (BT-CCRC). Switch on the test bench and the digital indicator. ZERO ADJUST CONTROL The test chamber power supply indicator must be unlit. If it is not, wait until the end of the time delay on the test chamber power supply (3 minutes). Push the SIDE button on the indicator (IN-CCRC); the LS (Long Side) indicator lights up. Take a reading from the digital indicator of the magnetic field value. If the value recorded is not within the 0 ± 1 Gauss range, do the zero adjust control using the potentiometer marked O", which is accessed via the back panel of the digital indicator. Push the SIDE button on the indicator (IN-CCRC); the SS (Short Side) indicator lights up. Take a reading from the digital indicator of the magnetic field value. If the value recorded is not within the 0 ± 1 Gauss range, do the zero adjust control using the potentiometer marked O", which is accessed via the back panel of the digital indicator. (SEE ATTACHMENT 1) SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 9/13

FULL SCALE ADJUSTMENT Push the button located on the top of the test bench (BT-CCRC). The test chamber power supply indicator lights up. Push the SIDE button on the indicator (IN-CCRC); the LS (Long Side) indicator lights up. Take a reading from the digital indicator of the magnetic field value. If the value recorded is not within the range 150 ± 5 Gauss, set the full scale to 150 Gauss using the potentiometer marked FS, which is accessed via the back panel of the digital indicator. Push the SIDE button on the indicator (IN-CCRC); the SS (Short Side) indicator lights up. Take a reading from the digital indicator of the magnetic field value. If the value recorded is not within the range 150 ± 5 Gauss, set the full scale to 150 Gauss using the potentiometer marked FS, which is accessed via the back panel of the digital indicator. (SEE ATTACHMENT 1) SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 10/13

TEST ON THE POT TEST OPERATION Check cleanliness of the cathode bars. The measurement cane cannot be positioned correctly if alumina or crust is present on the cathode bars. If required, clean the cathode bars with a longhandled brush. Lower the cathode current distribution control cane through the grating, between 2 pot cradles. Position the aluminium stirrup astride the cathode bar, against the pot shell stuffing box. Take a reading from the digital indicator of the magnetic field value between the two sensors (no sensor selected). Do not take account of the value sign. Note the results on the measurement sheet. Note the pot current at the time the measurements were taken. In order to be able to compare these measurements and monitor their changes over time, they must be expressed as equivalent values using a reference potline current. REMARK 1: POSITION OF THE CANE ON THE CATHODE BAR The measurement is very sensitive to the CCRC position on the cathode bar: it must be ensured that the measurement cane stops well up against the cathode bar. The cane must always be turned the same way (unless it is impossible to do so). Cane Long Side Short Side Cathode bar REMARK 2: PRECAUTIONS FOR USING THE DEVICE The CCRC must be cooled down using compressed air (for approx. 3 minutes) after measuring half a pot in order to reduce measurement deviations due to temperature. If sensor temperature exceeds 80 C, an indicator on the front panel of the digital indicator lights up. Measurements must be stopped and the CCRC cooled down (for approx. 3 minutes) using compressed air. If sensor temperature exceeds 100 C, the digital indicator display blocks. SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 11/13

ATTACHMENT 1 DIAGRAM DESCRIBING THE CHECKING OF THE CCRC CANE ON THE BT-CCRC TEST BENCH SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 12/13

LIST OF SPARE PARTS AND ACCESSORIES SPARE PARTS CCRC DESCRIPTION HALL EFFECT PROBE UNIT Batch of 10 spring plates to position the jumper on the bar Lamp bodies Batch of 10 lamp covers Batch of 10 lamps IN-CCRC DESCRIPTION Display module. Storage battery, Ni-Cd 6V/2,4Ah ACCESSORIES Wooden carrying case for control cane and indicator. (dimensions: 320x2100x100 mm - Weight: 6 kg) SEREM ELECTRONIQUE - CATHODE CURRENT DISTRIBUTION CONTROL DEVICE - INSTRUCTION MANUAL - REV 0 - P 13/13